Piper Fittings

11
7 7/16 Cable Glands DQM-I Series Explosion-proof Cable Glands (Ex e) Plastic Unarmored Cable Glands DQM-I Series Explosion-proof Cable Glands (Ex e) Plastic Unarmored  Explosion protection to  -CENELEC  -IEC Can be used in Zone 1 and Zone 2 Ex e structure, made of plastic, black. Single seal, suitable for unarmored cable. Technical data Explosion-proof cable glands DQM-I Ex e (plastic unarmored) Explosion protection Certificates Conformity to standards Gland material Degree of protection Ambient temperature Connection thread  II 2 G Ex e II PTB 04 ATEX 1087X; IECEx CQM 07.0009 EN 50014:1997+A1+A2, EN 50019:2000 IEC 60079-0:2004, IEC 60079-7:2001 Plastic, black IP65 -20 +55 Metric thread is standard type; G thread is opti onal, but limit ed at G3/ 4 ; NPT thread is not suitable. Selection table Versions Gland size 16 20 25 32 40 50 63 Standard entry thread B M16 x 1.5 M20 x 1.5 M25 x 1.5 M32 x 1.5 M40 x 1.5 M50 x 1.5 M63 x 1.5 Cable outer  diameter A (mm) 5 6 10 17 23 32 8 12 18 25 32 44 Minimum thread length  C (mm) 15 15 15 15 14 14 15 Ordering code 705001 705002 705003 705004 705005 705006 705007 Weight (kg) 0.05 0.05 0.05 0.05 0.10 0.11 0.15 Note: 1. Supplied with locknut (nickel plated brass) and seal gasket, without stopping rod. 2. Stopping rod on request. See P7/31. Max Min 9 12 13 16 Without stopping rod With stopping rod http:// www.waromgroup.com General Catalogue 01.01.2012

Transcript of Piper Fittings

8/12/2019 Piper Fittings

http://slidepdf.com/reader/full/piper-fittings 1/10

7

7/16

Cable Glands

DQM-I Series Explosion-proof Cable Glands (Ex e)

Plastic Unarmored

Cable Glands

DQM-I Series Explosion-proof Cable Glands (Ex e)

Plastic Unarmored

 Explosion protection to

  -CENELEC

  -IEC

Can be used in

Zone 1 and Zone 2

Ex e structure, made of plastic, black.

Single seal, suitable for unarmored cable.

Technical data

Explosion-proof cable glands DQM-I Ex e (plastic unarmored)

Explosion protection

Certificates

Conformity to standards

Gland material

Degree of protection

Ambient temperature

Connection thread

  II 2 G Ex e II

PTB 04 ATEX 1087X; IECEx CQM 07.0009

EN 50014:1997+A1+A2, EN 50019:2000

IEC 60079-0:2004, IEC 60079-7:2001

Plastic, black

IP65

-20 +55

Metric thread is standard type; G thread is optional, but limited at G3/4 ; NPT

thread is not suitable.

Selection table

VersionsGland

size

16

20

25

32

40

50

63

Standard

entry thread

B

M16 x 1.5

M20 x 1.5

M25 x 1.5

M32 x 1.5

M40 x 1.5

M50 x 1.5

M63 x 1.5

Cable outer  diameter A (mm)

5

6

10

17

23

32

8

12

18

25

32

44

Minimum

thread length

 C (mm)

15

15

15

15

14

14

15

Ordering

code

705001

705002

705003

705004

705005

705006

705007

Weight

(kg)

0.05

0.05

0.05

0.05

0.10

0.11

0.15

Note: 1. Supplied with locknut (nickel plated brass) and seal gasket, without stopping rod.

2. Stopping rod on request. See P7/31.

MaxMin

9

12

13

16

Without stopping rod

With stopping rod

http:// www.waromgroup.comGeneral Catalogue 01.01.2012

8/12/2019 Piper Fittings

http://slidepdf.com/reader/full/piper-fittings 2/10

7

7/17

Cable Glands

DQM-I Series Explosion-proof Cable Glands (Ex e)

Metal Unarmored

 Explosion protection to

  -CENELEC

  -IEC

Can be used in

Zone 1 and Zone 2

Ex e structure; available in stainless steel, nickel plated brass

or galvanized carbon steel.

Single seal, suitable for unarmored cable.

Cable Glands

DQM-I Series Explosion-proof Cable Glands (Ex e)

Metal Unarmored

Technical data

Explosion-proof cable glands DQM-I Ex e (metal unarmored)

Explosion protection

Certificates

Conformity to standards

Gland material

Degree of protection

Ambient temperature

Connection thread

  II 2 G Ex e II

PTB 04 ATEX 1087X; IECEx CQM 07.0009

EN 50014:1997+A1+A2, EN 50019:2000

IEC 60079-0:2004, IEC 60079-7:2001

Stainless steel, nickel plated brass or galvanized carbon steel

IP65

-20 +55

Metric thread is standard type; G thread or NPT thread is optional.

Selection table

VersionsGland

size

Standard

entry thread

B

Cable outer  diameter A (mm)

Minimum

thread length

 C (mm)

Ordering

code

Weight

(kg)MaxMin

20

25

32

40

50

63

M20 x 1.5

M25 x 1.5

M32 x 1.5

M40 x 1.5

M50 x 1.5

M63 x 1.5

5

10

14

18

22

32

10

14

18

25

32

44

15

15

17

17

17

17

706001

706002

706003

706004

706005

706006

0.15

0.15

0.30

0.50

0.55

0.70

Note: 1. Standard material is galvanized carbon steel. Nickel plated brass or stainless steel is optional. Weight above is based

  upon galvanized carbon steel.

  2. Supplied with locknut and seal gasket.  3. Earth lug and shroud on request. See P7/31.

http:// www.waromgroup.comGeneral Catalogue 01.01.2012

8/12/2019 Piper Fittings

http://slidepdf.com/reader/full/piper-fittings 3/10

7

7/18

Technical data

Cable Glands

DQM-I Series Explosion-proof Cable Glands (Ex e)

Metal Armored

Cable Glands

DQM-I Series Explosion-proof Cable Glands (Ex e)

Metal Armored

 Explosion protection to

  -CENELEC

  -IEC

Can be used in

Zone 1 and Zone 2

Ex e structure; available in stainless steel, nickel plated brass

or galvanized carbon steel.

Single seal, suitable for both armored and unarmored cable.

Cable wiring

Steel pipe wiring

Explosion-proof cable glands DQM-I Ex e (metal armored)

Explosion protection

Certificates

Conformity to standards

Gland material

Degree of protection

Ambient temperature

Connection thread

  II 2 G Ex e II

PTB 04 ATEX 1087X; IECEx CQM 07.0009

EN 50014:1997+A1+A2, EN 50019:2000

IEC 60079-0:2004, IEC 60079-7:2001

Stainless steel, nickel plated brass or galvanized carbon steel

IP65

-20 +55

Metric thread is standard type; G thread or NPT thread is optional.

Selection table

VersionsGland

size

Standard

entry thread

C

Cable outer  diameter B (mm)

Minimum

thread length

D (mm)

Ordering

code

Weight

(kg)MaxMin

Cable outer  diameter A (mm)

Max

Cable wiring

20S

20

25S

25

32S

32

40S

40

50S

50

63S

63

M20 x 1.5

M20 x 1.5

M25 x 1.5

M25 x 1.5

M32 x 1.5

M32 x 1.5

M40 x 1.5

M40 x 1.5

M50 x 1.5

M50 x 1.5

M63 x 1.5

M63 x 1.5

9

13

13

17

17

23

23

29

29

36

36

46

7

11

11

14

14

19

19

22

22

29

29

37

13

17

17

23

23

29

29

36

36

47

47

58

15

15

15

15

17

17

17

17

17

17

17

17

707001

707002

707003

707004

707005

707006

707007

707008

707009

707010

707011

707012

0.20

0.20

0.40

0.35

0.65

0.60

0.90

0.90

1.35

1.25

2.35

2.25

Note: 1. Standard material is nickel plated brass. Stainless steel or galvanized carbon steel is optional. Weight above is based

  upon nickel plated brass.

  2. Supplied with locknut and seal gasket.

  3. Earth lug and shroud on request. See P7/31.

http:// www.waromgroup.comGeneral Catalogue 01.01.2012

8/12/2019 Piper Fittings

http://slidepdf.com/reader/full/piper-fittings 4/10

7

7/19

Selection table

Versions

Cable Glands

DQM-I Series Explosion-proof Cable Glands (Ex e)

Metal Armored

Steel pipe wiring

Gland

size

Standard

entry thread

C

20S20

25S

25

32S

32

40S

40

50S

50

63S

63

M20 x 1.5M20 x 1.5

M25 x 1.5

M25 x 1.5

M32 x 1.5

M32 x 1.5

M40 x 1.5

M40 x 1.5

M50 x 1.5

M50 x 1.5

M63 x 1.5

M63 x 1.5

Note: 1. Standard material is nickel plated brass. Stainless steel or galvanized carbon steel is optional. Weight above is based

upon nickel plated brass.

  2. Supplied with locknut and seal gasket.

  3. Earth lug and shroud on request. See P7/31.

M20 x 1.5M25 x 1.5

M25 x 1.5

M32 x 1.5

M32 x 1.5

M40 x 1.5

M40 x 1.5

M50 x 1.5

M50 x 1.5

M63 x 1.5

M63 x 1.5

M75 x 1.5

Cable outer  diameter B (mm)

Minimum

thread length

D (mm)

Ordering

code

Weight

(kg)MaxMin

Cable outer  diameter A (mm)

Max

913

13

17

17

23

23

29

29

36

36

46

711

11

14

14

19

19

22

22

29

29

37

1317

17

23

23

29

29

36

36

47

47

58

1515

15

15

17

17

17

17

17

17

17

17

707013707014

707015

707016

707017

707018

707019

707020

707021

707022

707023

707024

0.250.20

0.45

0.40

0.70

0.65

1.05

0.95

1.45

1.40

2.55

2.45

Standard

entry thread

E

http:// www.waromgroup.comGeneral Catalogue 01.01.2012

8/12/2019 Piper Fittings

http://slidepdf.com/reader/full/piper-fittings 5/10

7

7/20 http:// www.waromgroup.comGeneral Catalogue 01.01.2012

Technical data

Selection table

VersionsGland

size

Standard

entry thread

B

Minimum

thread length

C (mm)

Ordering

code

Weight

(kg)

Cable outer  diameter A (mm)

Min

Cable wiring

Cable Glands

DQM-II Series Explosion-proof Cable Glands (Ex d IIC)

Unarmored Single Seal

Cable Glands

DQM-II Series Explosion-proof Cable Glands

(Ex d IIC) Unarmored Single Seal

 Explosion protection to

  -CENELEC

  -IEC

Can be used in

Zone 1 and Zone 2

Ex d structure; available in stainless steel, nickel plated brass

or galvanized carbon steel.

Single seal, suitable for unarmored cable.

Cable wiring

Steel pipe wiring

Explosion-proof cable glands DQM-II Ex d (unarmored single seal)

Explosion protection

Certificates

Conformity to standards

Gland material

Degree of protection

Ambient temperature

Connection thread

  II 2 G Ex d IIC

LCIE 06 ATEX 6100; IECEx LCI 08.0011

EN 60079-0:2004, EN 60079-1:2004

IEC 60079-0:2004, IEC 60079-1:2003

Stainless steel, nickel plated brass or galvanized carbon steel

IP65

-20 +55

Metric thread is standard type; G thread or NPT thread is optional.

Max

20

25

32

40

50

63

M20 x 1.5

M25 x 1.5

M32 x 1.5

M40 x 1.5

M50 x 1.5

M63 x 1.5

6.5

10

11

14

20

25

11

15

18

24

27

35

16

16

16

16

16

16

708001

708002

708003

708004

708005

708006

0.15

0.25

0.40

0.55

0.65

0.90

Note: 1. Standard material is galvanized carbon steel. Nickel plated brass or stainless steel is optional. Weight above is based

upon galvanized carbon steel.

  2. Supplied without locknut.

3. Earth lug and shroud on request. See P7/31.

8/12/2019 Piper Fittings

http://slidepdf.com/reader/full/piper-fittings 6/10

7

7/21http:// www.waromgroup.comGeneral Catalogue 01.01.2012

Selection table

VersionsGland

size

Standard

entry thread

B

Cable outer  diameter A (mm)

Minimum

thread length

C (mm)

Ordering

code

Weight

(kg)MaxMin

Steel pipe wiring

Cable Glands

DQM-II Series Explosion-proof Cable Glands (Ex d IIC)

Unarmored Single Seal

Standard

entry thread

D

20

25

32

40

50

63

M20 x 1.5

M25 x 1.5

M32 x 1.5

M40 x 1.5

M50 x 1.5

M63 x 1.5

M20 x 1.5

M25 x 1.5

M32 x 1.5

M40 x 1.5

M50 x 1.5

M63 x 1.5

10

12

15

18

26

30

14

17

23

30

37

47

15

15

17

17

17

17

708007

708008

708009

708010

708011

708012

0.20

0.25

0.40

0.60

0.75

1.15

Note: 1. Standard material is galvanized carbon steel. Nickel plated brass or stainless steel is optional. Weight above is based

upon galvanized carbon steel.

  2. Supplied without locknut.

3. Earth lug and shroud on request. See P7/31.

8/12/2019 Piper Fittings

http://slidepdf.com/reader/full/piper-fittings 7/10

7

7/22

Selection table

TypeGland

size

Standard

entry thread

C

Minimum

thread length

D (mm)

Ordering

code

Weight

(kg)

Cable outer  diameter A (mm)

Min

Cable wiring

Cable wiring

Steel pipe wiring

Max

Cable Glands

DQM-II Series Explosion-proof Cable Glands (Ex d IIC)

Armored Dual Seal

Cable Glands

DQM-II Series Explosion-proof Cable Glands

(Ex d IIC) Armored Dual Seal

 Explosion protection to

  -CENELEC

  -IEC

Can be used in

Zone 1 and Zone 2

Ex d structure; available in stainless steel, nickel plated brass

or galvanized carbon steel.

Dual seal, suitable for both armored and unarmored cable.

Technical data

Explosion-proof cable glands DQM-II Ex d (armored dual seal)

Explosion protection

Certificates

Conformity to standards

Gland material

Degree of protection

Ambient temperature

Connection thread

  II 2 G Ex d IIC

LCIE 06 ATEX 6100; IECEx LCI 08.0011

EN 60079-0:2004, EN 60079-1:2004

IEC 60079-0:2004, IEC 60079-1:2003

Stainless steel, nickel plated brass or galvanized carbon steel

IP66

-20 +55

Metric thread is standard type; G thread or NPT thread is optional.

Cable outer  diameter B (mm)

MaxMin

20S

20

25S

25

32S

32

40S

40

50S

50

63S

63

M20 x 1.5

M20 x 1.5

M25 x 1.5

M25 x 1.5

M32 x 1.5

M32 x 1.5

M40 x 1.5

M40 x 1.5

M50 x 1.5

M50 x 1.5

M63 x 1.5

M63 x 1.5

5

7

7

11

11

14

14

19

19

22

22

29

9

13

13

17

17

23

23

29

29

36

36

46

7

11

11

14

14

19

19

22

22

29

29

37

13

17

17

23

23

29

29

36

36

47

47

58

15

15

15

15

17

17

17

17

17

17

17

17

709001

709002

709003

709004

709005

709006

709007

709008

709009

709010

709011

709012

0.35

0.30

0.45

0.40

0.70

0.65

1.10

1.05

1.60

1.50

2.55

2.45

Note: 1. Standard material is nickel plated brass. Stainless steel or galvanized carbon steel is optional. Weight above is based

upon nickel plated brass.

  2. Supplied without locknut.

  3. Earth lug and shroud on request. See P7/31.

http:// www.waromgroup.comGeneral Catalogue 01.01.2012

8/12/2019 Piper Fittings

http://slidepdf.com/reader/full/piper-fittings 8/10

7

7/23

Selection table

VersionsGland

size

Standard

entry thread

C

Cable outer  diameter A (mm)

MaxMin

Steel pipe wiring

Standard

entry thread

E

Cable Glands

DQM-II Series Explosion-proof Cable Glands (Ex d IIC)

Armored Dual Seal

20S20

25S

25

32S

32

40S

40

50S

50

63S

63

M20 x 1.5M20 x 1.5

M25 x 1.5

M25 x 1.5

M32 x 1.5

M32 x 1.5

M40 x 1.5

M40 x 1.5

M50 x 1.5

M50 x 1.5

M63 x 1.5

M63 x 1.5

M20 x 1.5M25 x 1.5

M25 x 1.5

M32 x 1.5

M32 x 1.5

M40 x 1.5

M40 x 1.5

M50 x 1.5

M50 x 1.5

M63 x 1.5

M63 x 1.5

M75 x 1.5

57

7

11

11

14

14

19

19

22

22

29

913

13

17

17

23

23

29

29

36

36

46

711

11

14

14

19

19

22

22

29

29

37

1317

17

23

23

29

29

36

36

47

47

58

Minimum

thread length

D (mm)

1515

15

15

17

17

17

17

17

17

17

17

Ordering

code

709013709014

709015

709016

709017

709018

709019

709020

709021

709022

709023

709024

Weight

(kg)

0.400.35

0.50

0.45

0.75

0.70

1.20

1.15

1.70

1.65

2.75

2.70

MaxMin

Note: 1. Standard material is nickel plated brass. Stainless steel or galvanized carbon steel is optional. Weight above is based

  upon nickel plated brass.

  2. Supplied without locknut.

  3. Earth lug and shroud on request. See P7/31.

Cable outer  diameter B (mm)

http:// www.waromgroup.comGeneral Catalogue 01.01.2012

8/12/2019 Piper Fittings

http://slidepdf.com/reader/full/piper-fittings 9/10

7

7/24

Technical data

Selection table

VersionsGland

size

Standard

entry thread

C

Minimum

thread length

D (mm)

Ordering

code

Weight

(kg)

Cable outer  diameter A (mm)

Cable wiring

Max

Cable outer  diameter B (mm)

MaxMin

Cable Glands

DQM-III Series Explosion-proof Cable Glands (Ex d IIC)

Armored Compound Barrier 

Cable wiring

Steel pipe wiring

Cable Glands

DQM-III Series Explosion-proof Cable Glands

(Ex d IIC) Armored Compound Barrier 

 Explosion protection to

  -CENELEC

  -IEC

Can be used in

Zone 1 and Zone 2

Ex d structure; available in stainless steel, nickel plated brass

or galvanized carbon steel.

With seal ring and sealing compound; suitable for armored

cable.

The compound consists of type A and type B; it can solidify

  after mixing together

Explosion-proof cable glands DQM-III Ex d (armored compound barrier)

Explosion protection

Certificates

Conformity to standards

Gland material

Degree of protection

Ambient temperature

Connection thread

  II 2 G Ex d IIC Ex d IIC Gb

Nemko 10 ATEX 1005X; IECEx CQM 11.0028

EN 60079-0:2006, EN 60079-1:2004

IEC 60079-0:2007, IEC 60079-1:2007

Stainless steel, nickel plated brass or galvanized carbon steel

IP66

-20 +55

Metric thread is standard type; G thread or NPT thread is optional.

20S

20

25S

25

32S

32

40S

40

50S

50

63S

63

M20 x 1.5

M20 x 1.5

M25 x 1.5

M25 x 1.5

M32 x 1.5

M32 x 1.5

M40 x 1.5

M40 x 1.5

M50 x 1.5

M50 x 1.5

M63 x 1.5

M63 x 1.5

7

11

11

16

16

19

19

25

25

32

32

42

7

11

11

14

14

19

19

22

22

29

29

37

13

17

17

23

23

29

29

36

36

47

47

58

15

15

15

15

17

17

17

17

17

17

17

17

710001

710002

710003

710004

710005

710006

710007

710008

710009

710010

710011

710012

0.30

0.30

0.40

0.35

0.60

0.55

0.95

0.90

1.55

1.35

2.35

2.25

Note: 1. Standard material is nickel plated brass. Stainless steel or galvanized carbon steel is optional. Weight above is based

  upon nickel plated brass.

  2. Supplied without locknut.

  3. Earth lug and shroud on request. See P7/31.

http:// www.waromgroup.comGeneral Catalogue 01.01.2012

8/12/2019 Piper Fittings

http://slidepdf.com/reader/full/piper-fittings 10/10

7Selection table

VersionsGland

size

Standard

entry thread

C

Cable outer  diameter A (mm)

Steel pipe wiring

Standard

entry thread

E

Minimum

thread length

D (mm)

Ordering

code

Weight

(kg)Max MaxMin

Cable Glands

DQM-III Series Explosion-proof Cable Glands (Ex d IIC)

Armored Compound Barrier 

Cable outer  diameter B (mm)

20S20

25S

25

32S

32

40S

40

50S

50

63S

63

M20 x 1.5M20 x 1.5

M25 x 1.5

M25 x 1.5

M32 x 1.5

M32 x 1.5

M40 x 1.5

M40 x 1.5

M50 x 1.5

M50 x 1.5

M63 x 1.5

M63 x 1.5

M20 x 1.5M25 x 1.5

M25 x 1.5

M32 x 1.5

M32 x 1.5

M40 x 1.5

M40 x 1.5

M50 x 1.5

M50 x 1.5

M63 x 1.5

M63 x 1.5

M75 x 1.5

711

11

16

16

19

19

25

25

32

32

42

711

11

14

14

19

19

22

22

29

29

37

1317

17

23

23

29

29

36

36

47

47

58

1515

15

15

17

17

17

17

17

17

17

17

710013710014

710015

710016

710017

710018

710019

710020

710021

710022

710023

710024

0.350.30

0.45

0.40

0.70

0.65

1.05

0.05

1.55

1.50

2.55

2.45

Note: 1. Standard material is nickel plated brass. Stainless steel or galvanized carbon steel is optional. Weight above is based

  upon nickel plated brass.

  2. Supplied without locknut.

  3. Earth lug and shroud on request. See P7/31.