PINE & PALM HOLDINGS LLC...107MECHANICAL ROOMCONCRETESEALER4" VINYL GYPSUM WALL BOARDLATEX...

13
REVISION: PROJECT NAME CLIENT NAME REV DESCRIPTION DATE 5455 Freitag Drive Menomonie, WI 54751 (715)235-3541 Phone (715)235-9190 Fax 705 Bay Street Chippewa Falls, WI 54729 (715)723-5511 Phone www.cfbsi.com PROJECT: DATE: DRAWN BY: REVIEWED BY: THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION THAT CANNOT BE REPRODUCED OR DIVULGED, IN WHOLE OR IN PART, WITHOUT WRITTEN AUTHORIZATION FROM CFBSI PROPOSED BUILDING PINE & PALM HOLDINGS LLC COVER SHEET 19-029 4/16/2019 MDM CGR T100 1 1 FOR STATE APPROVAL 6/6/2019 PINE & PALM HOLDINGS LLC PROPOSED NEW BUILDING La Grandeur Road Somerset, WI 54025 T100 COVER SHEET SHEET INDEX A100 FLOOR PLAN S100 FOUNDATION PLAN VIEW A200 ELEVATIONS C101 SITE PLAN C102 GRADING PLAN C100 EXISTING SITE CONDITIONS BUILDING LOADS ROOF LIVE LOAD: 20.00 PSF REDUCIBLE LOAD BEARING VALUE OF SOIL: 2,000 PSF PRESUMPTIVE WIND SPEED: 115.00 MPH WIND ENCLOSURE: ENCLOSED WIND EXPOSURE: C-Kz: 0.936 GROUND SNOW LOAD: Pg: 50.00 PSF FLAT ROOF SNOW: pf: 31.50 PSF DESIGN SNOW (SLOPED): ps: 31.50 PSF SNOW IMPORTANCE FACTOR: Is: 1.000 GROUND/ROOF CONVERSION: 0.70 THERMAL FACTOR: HEATED-Ct: 1.00 SEISMIC DESIGN CATEGORY: A C103 EROSION CONTROL PLAN P I N E & P A L M H O L D I N G S L L C S101 FOUNDATION DETAILS SITE LOCATION PLAN NTS N GENERAL NOTES ALL WORK SHALL BE IN COMPLIANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS AND CODES. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS AND CONDITIONS. APPLICABLE BUILDING CODES: WISCONSIN BUILDING CODE, IBC 2015, IECC 2015. SITE GRADING DESIGN, HVAC, ELECTRICAL, LIGHTING, & EMERGENCY EGRESS LIGHTING NOT BY ARCHITECT. BUILDING SUPERSTRUCTURE BY BUTLER MFG. TO BE SUBMITTED AS A SEPARATE COMPONENT. CONSTRUCTION NOTES A. CONTRACTOR SHALL NOTIFY UTILITIES AND HAVE ALL UTILITIES LOCATED PRIOR TO EXCAVATION. B. CONTRACTOR SHALL MAINTAIN TRAFFIC ACCESSIBILITY ALONG PROJECT. C. EXISTING LOCATIONS ARE APPROXIMATE, CONTRACTOR TO FIELD VERIFY ALL LOCATIONS. SOIL PREPARATION AND FOUNDATIONS A. MATERIALS 1. FOOTINGS TO BEAR ON PROPERLY COMPACTED FILL OR NATIVE SOIL CAPABLE OF SUSTAINING A BEARING PRESSURE OF 2,000 PSF. THIS IS A PRESUMPTIVE VALUE. IF ANY SOIL APPEARS TO BE QUESTIONABLE, CONTACT THE ARCHITECT IMMEDIATELY. 2. ALL FILL MATERIAL TO BE GRANULAR SOIL OR OTHER COHESIONLESS MATERIAL APPROVED BY THE SOIL TESTING AGENCY. 3. GRANULAR SUB BASE (6" MINIMUM) UNDER SLABS ON GRADE TO HAVE PARTICLE GRADING TO THE FOLLOWING LIMITS: PASS 1" MESH: 100%. PASS #4 SIEVE: NOT OVER 5%. PASS #200 SIEVE: NOT OVER 1%. 4. A VAPOR BARRIER UNDER SLAB IS REQUIRED WHERE NOTED ON PLAN SHEET S100. B. INSTALLATION NOTES 1. PRIOR TO INSTALLING FOUNDATIONS, SOIL TO BE FIELD INSPECTED, WHEN REQUIRED, BY AN INDEPENDENT TESTING AGENCY FAMILIAR WITH THE SITE TO ASSURE THAT THE COMPACTION SPECIFICATIONS HAVE BEEN SATISFIED. SUBMIT ALL INSPECTION REPORTS TO THE ARCHITECT. 2. ALL TOPSOIL TO BE STRIPPED FROM BUILDING AND PAVEMENT AREAS. ALL VERY LOOSE SANDS AND SILT AND CLAY SOILS ALSO TO BE STRIPPED. 3. ALL FILL MATERIAL TO BE SPREAD IN MAXIMUM 6" LOOSE LIFTS AND COMPACTED WITH VIBRATORY COMPACTORS TO THE SPECIFICATIONS OF THE SOIL TESTING COMPANY. 4. SOIL COMPACTION AROUND AND ABOVE UTILITIES PASSING UNDER FOUNDATIONS TO CONFORM TO FOUNDATION COMPACTION CRITERIA. 5. PROVIDE MINIMUM 3'-6" SOIL COVER FOR FOUNDATION FROST PROTECTION IN HEATED AREAS AND 4'-6" IN UNHEATED AREAS. CONCRETE - SITE CAST A. DESIGN CODE: ACI 318, ACI "MANUAL OF STANDARD PRACTICE...", LATEST ADOPTION. B. MATERIALS 1. MINIMUM CONCRETE STRENGTH AT 28 DAYS (f'c) FOR SLABS ON GRADE TO BE 4000 PSI & FOR FOOTINGS & WALLS 3500 PSI. 2. CONCRETE SUPPLIER TO SUBMIT CONCRETE DESIGN MIX DESIGNS TO ARCHITECT AND GENERAL CONTRACTOR FOR ALL SITE CAST CONCRETE UPON REQUEST. 3. FURNISH 5-7% AIR ENTRAINING AGENT FOR ALL CONCRETE EXPOSED TO FREEZING TEMPERATURES. 4. REINFORCING STEEL a. WELDED WIRE FABRIC- ASTM A185, Fy=60 KSI MINIMUM b. DEFORMED BARS- ASTM A615, GRADE 60. REINFORCING STEEL BARS SHALL BE MARKED PHYSICALLY WITH THE SAME DESIGNATIONS AS SHOWN ON THE STRUCTURAL DRAWINGS. c. WELDED DEFORMED BARS- ASTM A706, GRADE 60. 5. INSTALL SLAB ON GRADE CONTROL JOINTS AS SHOWN ON PLANS AND DETAILS OR IN ACCORDANCE WITH PCA PUBLICATION "CONCRETE FLOORS ON GROUND". REFER TO PAGE 21 FOR REINFORCED SLABS AND PAGES 23 AND 24 FOR SLABS WITH DISTRIBUTED REINFORCEMENT. 6. PROVIDE DOWELS ACROSS JOINTS AS SHOWN ON DRAWINGS. C. WHEN DIRECTED, PROVIDE ALL INSPECTION REPORTS, MATERIAL TEST REPORTS, ETC. TO THE ARCHITECT. D. WHEN REQUESTED BY ARCHITECT, SUBMIT SHOP DRAWINGS FOR REINFORCING STEEL. E. INSTALLATION NOTES 1. ALL ITEMS TO BE PLACED IN ACCORDANCE WITH APPROVED SHOP DRAWINGS. 2. PROVIDE WIRE SPACERS, CHAIRS, AND TIES FOR SUPPORT OF REINFORCING. SHOW ON SHOP DRAWINGS. MESH TO BE INDEPENDENTLY SUPPORTED EVERY 25 SF (MINIMUM) USING CRSI RECOMMENDED SUPPORTS. 3. SUPPORT REINFORCEMENT ONLY WITH CRSI RECOMMENDED BAR SUPPORTS (WOOD, BRICK, ETC. NOT ACCEPTABLE) OR HANG FROM TOP OF FORMS. USE SUPPORTS WITH SAND PLATES OR HORIZONTAL RUNNERS FOR SLAB ON GRADE REINFORCEMENT. 4. CONCRETE COVER PER ACI 318, LATEST ADOPTION. 5. SAWCUT SLABS ON GRADE AS SOON AS CONCRETE MAY BE WORKED WITHOUT UNRAVELING (MAXIMUM 6 HOURS AFTER PLACEMENT) 6. PLACE AND SECURELY TIE FOOTING DOWELS IN POSITION PRIOR TO CONCRETE PLACEMENT - DO NOT EMBED DOWELS INTO WET CONCRETE. A300 BUILDING SECTION & DETAILS BUILDING DATA CONSTRUCTION TYPE: IIB BUILDING AREA MAIN FLOOR: 30,000 SF TOTAL B- 598 SF S1- 29,402 SF IBC 903.2.9 SPRINKLER SYSTEM REQUIRED IBC TABLE 506.2 ALLOWS 92,000 SF "B" BUILDING AREA 70,000 SF "S-1" BUILDING AREA MAXIMUM ACTUAL EXIT DISTANCE: 118' IBC TABLE 1017.2 ALLOWS 250' EXIT DISTANCE IBC 1013 PROVIDE EXIT LIGHTS PER THIS SECTION IBC 1008 PROVIDE EXIT ILLUMINATION PER THIS SECTION THERE WILL BE NO HIGH PILED COMBUSTIBLE STORAGE STORAGE OF CLASS I-IV <12' HIGH STORAGE OF GROUP A PLASTIC <6' HIGH PER IFC CHAPTER 32 & SPS 362.0202 C104 UTILITY PLAN C105 SITE DETAILS C106 SITE DETAILS **ALL CIVIL DRAWINGS** BY CEDAR CORP ENERGY COMPLIANCE ROOF REQUIRED: U-.049 PROVIDED: U-.031 WALLS REQUIRED: U-.069 PROVIDED: U-.052 UNHEATED SLAB ON GRADE REQUIRED: R-10 PROVIDED: R-10

Transcript of PINE & PALM HOLDINGS LLC...107MECHANICAL ROOMCONCRETESEALER4" VINYL GYPSUM WALL BOARDLATEX...

  • REVISION:

    PR

    OJE

    CT

    N

    AM

    E

    CL

    IE

    NT

    N

    AM

    E

    RE

    VD

    ES

    CR

    IP

    TIO

    ND

    AT

    E

    54

    55

    F

    re

    ita

    g D

    rive

    Me

    no

    mo

    nie

    , W

    I

    54

    75

    1

    (7

    15

    )2

    35

    -3

    54

    1 P

    ho

    ne

    (7

    15

    )2

    35

    -9

    19

    0 F

    ax

    70

    5 B

    ay S

    tre

    et

    Ch

    ip

    pe

    wa

    F

    alls, W

    I

    54

    72

    9

    (7

    15

    )7

    23

    -5

    51

    1 P

    ho

    ne

    ww

    w.cfb

    si.co

    m

    PROJECT:

    DATE:

    DRAWN BY:

    REVIEWED BY:

    TH

    IS

    D

    OC

    UM

    EN

    T C

    ON

    TA

    IN

    S C

    ON

    FID

    EN

    TIA

    L A

    ND

    P

    RO

    PR

    IE

    TA

    RY

    IN

    FO

    RM

    AT

    IO

    N T

    HA

    T C

    AN

    NO

    T B

    E

    RE

    PR

    OD

    UC

    ED

    O

    R D

    IV

    UL

    GE

    D, IN

    W

    HO

    LE

    O

    R IN

    P

    AR

    T, W

    IT

    HO

    UT

    W

    RIT

    TE

    N A

    UT

    HO

    RIZ

    AT

    IO

    N F

    RO

    M C

    FB

    SI

    PR

    OP

    OS

    ED

    B

    UIL

    DIN

    G

    PIN

    E &

    P

    AL

    M H

    OL

    DIN

    GS

    L

    LC

    CO

    VE

    R S

    HE

    ET

    19-029

    4/16/2019

    MDM

    CGR

    T100

    1

    1F

    OR

    S

    TA

    TE

    A

    PP

    RO

    VA

    L6/6/2019

    PINE & PALM HOLDINGS LLC

    PROPOSED NEW BUILDING

    La Grandeur Road

    Somerset, WI 54025

    T100 COVER SHEET

    SHEET INDEX

    A100 FLOOR PLAN

    S100 FOUNDATION PLAN VIEW

    A200 ELEVATIONS

    C101 SITE PLAN

    C102 GRADING PLAN

    C100 EXISTING SITE CONDITIONS

    BUILDING LOADS

    ROOF LIVE LOAD: 20.00 PSF REDUCIBLE

    LOAD BEARING VALUE OF SOIL: 2,000 PSF PRESUMPTIVE

    WIND SPEED: 115.00 MPH

    WIND ENCLOSURE: ENCLOSED

    WIND EXPOSURE: C-Kz: 0.936

    GROUND SNOW LOAD: Pg: 50.00 PSF

    FLAT ROOF SNOW: pf: 31.50 PSF

    DESIGN SNOW (SLOPED): ps: 31.50 PSF

    SNOW IMPORTANCE FACTOR: Is: 1.000

    GROUND/ROOF CONVERSION: 0.70

    THERMAL FACTOR: HEATED-Ct: 1.00

    SEISMIC DESIGN CATEGORY: A

    C103 EROSION CONTROL PLAN

    PIN

    E

    &

    P

    A

    L

    M

    HO

    L

    D

    I

    N

    G

    S

    L

    L

    C

    S101 FOUNDATION DETAILS

    SITE LOCATION PLAN

    NTS

    N

    GENERAL NOTES

    ALL WORK SHALL BE IN COMPLIANCE WITH LOCAL, STATE AND FEDERAL

    REGULATIONS AND CODES.

    DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS AND CONDITIONS.

    APPLICABLE BUILDING CODES:

    WISCONSIN BUILDING CODE, IBC 2015, IECC 2015.

    SITE GRADING DESIGN, HVAC, ELECTRICAL, LIGHTING,

    & EMERGENCY EGRESS LIGHTING NOT BY ARCHITECT.

    BUILDING SUPERSTRUCTURE BY BUTLER MFG. TO BE SUBMITTED AS

    A SEPARATE COMPONENT.

    CONSTRUCTION NOTES

    A. CONTRACTOR SHALL NOTIFY UTILITIES AND HAVE ALL

    UTILITIES LOCATED PRIOR TO EXCAVATION.

    B. CONTRACTOR SHALL MAINTAIN TRAFFIC ACCESSIBILITY

    ALONG PROJECT.

    C. EXISTING LOCATIONS ARE APPROXIMATE, CONTRACTOR TO FIELD

    VERIFY ALL LOCATIONS.

    SOIL PREPARATION AND FOUNDATIONS

    A. MATERIALS

    1. FOOTINGS TO BEAR ON PROPERLY COMPACTED FILL OR NATIVE SOIL CAPABLE OF SUSTAINING A BEARING PRESSURE OF

    2,000 PSF. THIS IS A PRESUMPTIVE VALUE. IF ANY SOIL APPEARS TO BE QUESTIONABLE, CONTACT THE ARCHITECT IMMEDIATELY.

    2. ALL FILL MATERIAL TO BE GRANULAR SOIL OR OTHER COHESIONLESS MATERIAL APPROVED BY THE SOIL TESTING AGENCY.

    3. GRANULAR SUB BASE (6" MINIMUM) UNDER SLABS ON GRADE TO HAVE PARTICLE GRADING TO THE FOLLOWING LIMITS:

    PASS 1" MESH: 100%. PASS #4 SIEVE: NOT OVER 5%. PASS #200 SIEVE: NOT OVER 1%.

    4. A VAPOR BARRIER UNDER SLAB IS REQUIRED WHERE NOTED ON PLAN SHEET S100.

    B. INSTALLATION NOTES

    1. PRIOR TO INSTALLING FOUNDATIONS, SOIL TO BE FIELD INSPECTED, WHEN REQUIRED, BY AN INDEPENDENT TESTING AGENCY

    FAMILIAR WITH THE SITE TO ASSURE THAT THE COMPACTION SPECIFICATIONS HAVE BEEN SATISFIED. SUBMIT ALL INSPECTION

    REPORTS TO THE ARCHITECT.

    2. ALL TOPSOIL TO BE STRIPPED FROM BUILDING AND PAVEMENT AREAS. ALL VERY LOOSE SANDS AND SILT AND CLAY SOILS

    ALSO TO BE STRIPPED.

    3. ALL FILL MATERIAL TO BE SPREAD IN MAXIMUM 6" LOOSE LIFTS AND COMPACTED WITH VIBRATORY COMPACTORS TO THE

    SPECIFICATIONS OF THE SOIL TESTING COMPANY.

    4. SOIL COMPACTION AROUND AND ABOVE UTILITIES PASSING UNDER FOUNDATIONS TO CONFORM TO FOUNDATION COMPACTION CRITERIA.

    5. PROVIDE MINIMUM 3'-6" SOIL COVER FOR FOUNDATION FROST PROTECTION IN HEATED AREAS AND 4'-6" IN UNHEATED AREAS.

    CONCRETE - SITE CAST

    A. DESIGN CODE: ACI 318, ACI "MANUAL OF STANDARD PRACTICE...", LATEST ADOPTION.

    B. MATERIALS

    1. MINIMUM CONCRETE STRENGTH AT 28 DAYS (f'c) FOR SLABS ON GRADE TO BE 4000 PSI & FOR FOOTINGS & WALLS 3500 PSI.

    2. CONCRETE SUPPLIER TO SUBMIT CONCRETE DESIGN MIX DESIGNS TO ARCHITECT AND GENERAL CONTRACTOR FOR ALL

    SITE CAST CONCRETE UPON REQUEST.

    3. FURNISH 5-7% AIR ENTRAINING AGENT FOR ALL CONCRETE EXPOSED TO FREEZING TEMPERATURES.

    4. REINFORCING STEEL

    a. WELDED WIRE FABRIC- ASTM A185, Fy=60 KSI MINIMUM

    b. DEFORMED BARS- ASTM A615, GRADE 60. REINFORCING STEEL BARS SHALL BE MARKED PHYSICALLY WITH THE SAME

    DESIGNATIONS AS SHOWN ON THE STRUCTURAL DRAWINGS.

    c. WELDED DEFORMED BARS- ASTM A706, GRADE 60.

    5. INSTALL SLAB ON GRADE CONTROL JOINTS AS SHOWN ON PLANS AND DETAILS OR IN ACCORDANCE WITH PCA PUBLICATION

    "CONCRETE FLOORS ON GROUND". REFER TO PAGE 21 FOR REINFORCED SLABS AND PAGES 23 AND 24 FOR SLABS WITH

    DISTRIBUTED REINFORCEMENT.

    6. PROVIDE DOWELS ACROSS JOINTS AS SHOWN ON DRAWINGS.

    C. WHEN DIRECTED, PROVIDE ALL INSPECTION REPORTS, MATERIAL TEST REPORTS, ETC. TO THE ARCHITECT.

    D. WHEN REQUESTED BY ARCHITECT, SUBMIT SHOP DRAWINGS FOR REINFORCING STEEL.

    E. INSTALLATION NOTES

    1. ALL ITEMS TO BE PLACED IN ACCORDANCE WITH APPROVED SHOP DRAWINGS.

    2. PROVIDE WIRE SPACERS, CHAIRS, AND TIES FOR SUPPORT OF REINFORCING. SHOW ON SHOP DRAWINGS. MESH TO BE

    INDEPENDENTLY SUPPORTED EVERY 25 SF (MINIMUM) USING CRSI RECOMMENDED SUPPORTS.

    3. SUPPORT REINFORCEMENT ONLY WITH CRSI RECOMMENDED BAR SUPPORTS (WOOD, BRICK, ETC. NOT ACCEPTABLE) OR HANG

    FROM TOP OF FORMS. USE SUPPORTS WITH SAND PLATES OR HORIZONTAL RUNNERS FOR SLAB ON GRADE REINFORCEMENT.

    4. CONCRETE COVER PER ACI 318, LATEST ADOPTION.

    5. SAWCUT SLABS ON GRADE AS SOON AS CONCRETE MAY BE WORKED WITHOUT UNRAVELING (MAXIMUM 6 HOURS AFTER PLACEMENT)

    6. PLACE AND SECURELY TIE FOOTING DOWELS IN POSITION PRIOR TO CONCRETE PLACEMENT - DO NOT EMBED DOWELS INTO WET CONCRETE.

    A300 BUILDING SECTION & DETAILS

    BUILDING DATA

    CONSTRUCTION TYPE: IIB

    BUILDING AREA

    MAIN FLOOR: 30,000 SF TOTAL

    B- 598 SF

    S1- 29,402 SF

    IBC 903.2.9 SPRINKLER SYSTEM REQUIRED

    IBC TABLE 506.2 ALLOWS 92,000 SF "B" BUILDING AREA

    70,000 SF "S-1" BUILDING AREA

    MAXIMUM ACTUAL EXIT DISTANCE: 118'

    IBC TABLE 1017.2 ALLOWS 250' EXIT DISTANCE

    IBC 1013 PROVIDE EXIT LIGHTS PER THIS SECTION

    IBC 1008 PROVIDE EXIT ILLUMINATION PER THIS SECTION

    THERE WILL BE NO HIGH PILED COMBUSTIBLE STORAGE

    STORAGE OF CLASS I-IV

  • 125'-0" 125'-0"

    120'-0"

    250'-0"

    49'-10" 49'-10"

    55'-0" 23'-6" 11'-6" 28'-0" 14'-0" 28'-0" 11'-6" 23'-6" 55'-0"

    102

    OFFICE

    104

    T.R.

    100

    WAREHOUSE

    101

    WAREHOUSE

    103

    OFFICE

    105

    T.R.

    2

    A200

    2

    A100

    1

    A200

    3

    A200

    4

    A200

    3

    A100

    62'-6"125'-0"

    101C 101A 101B 101B 101A 101D

    101E 101F

    101G

    101H

    101K

    101J

    W01 W01

    ILLUMINATED

    EXIT SIGN

    ILLUMINATED

    EXIT SIGN

    ILLUMINATED

    EXIT SIGN

    ILLUMINATED

    EXIT SIGN

    62'-6"

    TY

    PIC

    AL E

    GR

    ES

    S P

    AT

    H

    TY

    PIC

    AL E

    GR

    ES

    S P

    AT

    H

    FE

    TYPICAL SURFACE MOUNTED #10

    ABC TYPE FIRE EXTINGUISHER

    FE

    FE

    101L101M

    106

    MECH.

    107

    MECH.

    FE

    TYPICAL SURFACE MOUNTED #10

    ABC TYPE FIRE EXTINGUISHER

    FE FE

    7'-0" 11'-0"

    9'-6"

    14'-6"

    2'-5"

    2'-3"

    102

    OFFICE

    104

    TOILET ROOM

    7'-0"

    9'-8"

    106

    MECH.

    101K

    101J

    101L

    2x2 CEILING GRID (TYP.)

    LIGHT LOCATIONS

    REVISION:

    PR

    OJE

    CT

    N

    AM

    E

    CL

    IE

    NT

    N

    AM

    E

    RE

    VD

    ES

    CR

    IP

    TIO

    ND

    AT

    E

    54

    55

    F

    re

    ita

    g D

    rive

    Me

    no

    mo

    nie

    , W

    I

    54

    75

    1

    (7

    15

    )2

    35

    -3

    54

    1 P

    ho

    ne

    (7

    15

    )2

    35

    -9

    19

    0 F

    ax

    70

    5 B

    ay S

    tre

    et

    Ch

    ip

    pe

    wa

    F

    alls, W

    I

    54

    72

    9

    (7

    15

    )7

    23

    -5

    51

    1 P

    ho

    ne

    ww

    w.cfb

    si.co

    m

    PROJECT:

    DATE:

    DRAWN BY:

    REVIEWED BY:

    TH

    IS

    D

    OC

    UM

    EN

    T C

    ON

    TA

    IN

    S C

    ON

    FID

    EN

    TIA

    L A

    ND

    P

    RO

    PR

    IE

    TA

    RY

    IN

    FO

    RM

    AT

    IO

    N T

    HA

    T C

    AN

    NO

    T B

    E

    RE

    PR

    OD

    UC

    ED

    O

    R D

    IV

    UL

    GE

    D, IN

    W

    HO

    LE

    O

    R IN

    P

    AR

    T, W

    IT

    HO

    UT

    W

    RIT

    TE

    N A

    UT

    HO

    RIZ

    AT

    IO

    N F

    RO

    M C

    FB

    SI

    PR

    OP

    OS

    ED

    B

    UIL

    DIN

    G

    PIN

    E &

    P

    AL

    M H

    OL

    DIN

    GS

    L

    LC

    FL

    OO

    R P

    LA

    N

    19-029

    4/16/2019

    MDM

    CGR

    A100

    1

    1F

    OR

    S

    TA

    TE

    A

    PP

    RO

    VA

    L6/6/2019

    FLOOR PLAN

    3/32"=1'-0"

    ENLARGED FLOOR PLAN

    3/8"=1'-0"

    N

    REFLECTED CEILING PLAN

    3/8"=1'-0"

    2

    A100

    3

    A100

    1

    A100

  • 101A

    101C

    W01

    101B

    W01

    FEDCBA G

    1 2 3 4 5 6 7 8 9 10 11

    1234567891011

    F E D C B AG

    101D

    W01W01

    101A

    101B

    24'-0"

    24'-0"

    24'-0"

    12

    1/2

    12

    1/2

    12

    1/2

    12

    1/2

    WALL PACK

    5" DOWNSPOUT TYP.

    SPLASHBLOCK TYP.

    8 1/2" GUTTER

    24 GAUGE BUTLER MR-24

    STANDING SEAM ROOF SYSTEM

    26 GAUGE PRE-FINISHED

    SHADOWALL STEEL SIDING

    26 GAUGE PRE-FINISHED

    SHADOWALL STEEL SIDING

    26 GAUGE PRE-FINISHED

    SHADOWALL STEEL SIDING

    26 GAUGE PRE-FINISHED

    SHADOWALL STEEL SIDING

    24'-0"

    8 1/2" GUTTER

    24 GAUGE BUTLER MR-24

    STANDING SEAM ROOF SYSTEM

    WALL PACK WALL PACK WALL PACK WALL PACKWALL PACK

    5" DOWNSPOUT TYP.

    SPLASHBLOCK TYP.

    58'-0"

    50'-0"

    101F 101E

    WALL PACKWALL PACK

    70'-0"

    1'-0"

    8'-0"

    REVISION:

    PR

    OJE

    CT

    N

    AM

    E

    CL

    IE

    NT

    N

    AM

    E

    RE

    VD

    ES

    CR

    IP

    TIO

    ND

    AT

    E

    54

    55

    F

    re

    ita

    g D

    rive

    Me

    no

    mo

    nie

    , W

    I

    54

    75

    1

    (7

    15

    )2

    35

    -3

    54

    1 P

    ho

    ne

    (7

    15

    )2

    35

    -9

    19

    0 F

    ax

    70

    5 B

    ay S

    tre

    et

    Ch

    ip

    pe

    wa

    F

    alls, W

    I

    54

    72

    9

    (7

    15

    )7

    23

    -5

    51

    1 P

    ho

    ne

    ww

    w.cfb

    si.co

    m

    PROJECT:

    DATE:

    DRAWN BY:

    REVIEWED BY:

    TH

    IS

    D

    OC

    UM

    EN

    T C

    ON

    TA

    IN

    S C

    ON

    FID

    EN

    TIA

    L A

    ND

    P

    RO

    PR

    IE

    TA

    RY

    IN

    FO

    RM

    AT

    IO

    N T

    HA

    T C

    AN

    NO

    T B

    E

    RE

    PR

    OD

    UC

    ED

    O

    R D

    IV

    UL

    GE

    D, IN

    W

    HO

    LE

    O

    R IN

    P

    AR

    T, W

    IT

    HO

    UT

    W

    RIT

    TE

    N A

    UT

    HO

    RIZ

    AT

    IO

    N F

    RO

    M C

    FB

    SI

    PR

    OP

    OS

    ED

    B

    UIL

    DIN

    G

    PIN

    E &

    P

    AL

    M H

    OL

    DIN

    GS

    L

    LC

    EL

    EV

    AT

    IO

    NS

    19-029

    4/16/2019

    MDM

    CGR

    A200

    1

    1F

    OR

    S

    TA

    TE

    A

    PP

    RO

    VA

    L6/6/2019

    NORTH ELEVATION

    3/32"=1'-0"

    1

    A200

    SOUTH ELEVATION

    3/32"=1'-0"

    2

    A200

    EAST ELEVATION

    3/32"=1'-0"

    3

    A200

    WEST ELEVATION

    3/32"=1'-0"

    4

    A200

    TAG TYPE SIZE MATERIAL FINISH COUNT

    W01 SLIDING 4'-0"x4'-6" ALUMINUM BRINZE 4

    WINDOW SCHEDULE

    DOOR & HARDWARE SCHEDULE

    TAG TYPE SIZE FINISH SWING COUNT REMARKS

    101A INSULATED ROLL-UP 16'x16' FACTORY - 2 MANUAL

    101B INSULATED ROLL-UP 8'x9' FACTORY - 2 MANUAL

    101C INSULATED HOLLOW METAL 3'x7' FACTORY RHR 1 24"x30" LITE

    101D INSULATED HOLLOW METAL 3'x7' FACTORY LHR 1 24"x30" LITE

    101E INSULATED HOLLOW METAL 3'x7' FACTORY LHR 1

    101F INSULATED HOLLOW METAL 3'x7' FACTORY RHR 1

    101G HOLLOW METAL 3'x7' FACTORY RH 1

    101H HOLLOW METAL 3'x7' FACTORY LH 1

    101J HOLLOW METAL 3'x7' FACTORY RH 1

    101K HOLLOW METAL 3'x7' FACTORY LH 1

    101L HOLLOW METAL 3'x7' FACTORY LH 1

    101M HOLLOW METAL 3'x7' FACTORY RH 1

    LO

    CK

    SE

    T

    PA

    SS

    AG

    E

    PR

    IV

    AC

    Y

    PA

    NIC

    H

    AR

    DW

    AR

    E

    LA

    TC

    H G

    UA

    RD

    KIC

    K P

    LA

    TE

    CLO

    SE

    R

    TH

    RE

    SH

    OLD

    WE

    AT

    HE

    RS

    TR

    IP

    SW

    EE

    P

    ROOM FINISH SCHEDULE

    TAG ROOM FLOOR BASE NORTH WALL WEST WALL SOUTH WALL EAST WALL CEILING

    BASE MATERIAL FINISH BASE MATERIAL FINISH BASE MATERIAL FINISH BASE MATERIAL FINISH BASE MATERIAL FINISH BASE MATERIAL FINISH HEIGHT

    100 WAREHOUSE CONCRETE SEALER ------- INSULATION FABRIC 8' LINER PANEL INSULATION FABRIC 8' LINER PANEL INSULATION FABRIC 8' LINER PANEL INSULATION FABRIC 8' LINER PANEL INSULATION FABRIC ------- 24'-0"

    101 WAREHOUSE CONCRETE SEALER ------- INSULATION FABRIC 8' LINER PANEL INSULATION FABRIC 8' LINER PANEL INSULATION FABRIC 8' LINER PANEL INSULATION FABRIC 8' LINER PANEL INSULATION FABRIC ------- 24'-0"

    102 OFFICE CONCRETE VCT 4" VINYL GYPSUM WALL BOARD LATEX PAINT GYPSUM WALL BOARD LATEX PAINT GYPSUM WALL BOARD LATEX PAINT GYPSUM WALL BOARD LATEX PAINT 2'x2' ACOUSTIC TILE PRE-FINISHED 8'-0"

    103 OFFICE CONCRETE VCT 4" VINYL GYPSUM WALL BOARD LATEX PAINT GYPSUM WALL BOARD LATEX PAINT GYPSUM WALL BOARD LATEX PAINT GYPSUM WALL BOARD LATEX PAINT 2'x2' ACOUSTIC TILE PRE-FINISHED 8'-0"

    104 TOILET ROOM CONCRETE VCT 4" VINYL GYPSUM WALL BOARD LATEX PAINT GYPSUM WALL BOARD LATEX PAINT GYPSUM WALL BOARD LATEX PAINT GYPSUM WALL BOARD LATEX PAINT 2'x2' VINYLROCK TILE PRE-FINISHED 8'-0"

    105 TOILET ROOM CONCRETE VCT 4" VINYL GYPSUM WALL BOARD LATEX PAINT GYPSUM WALL BOARD LATEX PAINT GYPSUM WALL BOARD LATEX PAINT GYPSUM WALL BOARD LATEX PAINT 2'x2' VINYLROCK TILE PRE-FINISHED 8'-0"

    106 MECHANICAL ROOM CONCRETE SEALER 4" VINYL GYPSUM WALL BOARD LATEX PAINT GYPSUM WALL BOARD LATEX PAINT GYPSUM WALL BOARD LATEX PAINT GYPSUM WALL BOARD LATEX PAINT 2'x2' ACOUSTIC TILE PRE-FINISHED 8'-0"

    107 MECHANICAL ROOM CONCRETE SEALER 4" VINYL GYPSUM WALL BOARD LATEX PAINT GYPSUM WALL BOARD LATEX PAINT GYPSUM WALL BOARD LATEX PAINT GYPSUM WALL BOARD LATEX PAINT 2'x2' ACOUSTIC TILE PRE-FINISHED 8'-0"

  • TYPICAL ROOF SYSTEM:

    24 GAUGE BUTLER MR-24 STANDING SEAM ROOF SYSTEM

    8 1/2" PURLINS

    SIMPLE SAVER INSULATION SYSTEM

    12" (8"+4") w/THERMAL BLOCK R-38

    TYPICAL EXTERIOR WALL SYSTEM:

    26 GAUGE PRE-FINISHED SHADOWALL STEEL SIDING

    8 1/2" GIRTS

    SIMPLE SAVER INSULATION SYSTEM

    9" w/THERMAL BLOCK R-30

    FEDCBA G

    8' WHITE LINER PANEL

    8'-0"

    2'-0"

    TYPICAL CEILING ASSEMBLY:

    6" 20ga METAL STUDS

    WHITE PRO-RIB LINER PANELS EXTERIOR

    2x2 SUSPENDED GRID CEILING INTERIOR

    TYPICAL WALL ASSEMBLY:

    3 5/8" 20ga METAL STUDS

    4" R-13 FIBERGLASS INSULATION

    5/8" GYPSUM WALL BOARD BOTH SIDES 103

    OFFICE

    101

    WAREHOUSE

    REVISION:

    PR

    OJE

    CT

    N

    AM

    E

    CL

    IE

    NT

    N

    AM

    E

    RE

    VD

    ES

    CR

    IP

    TIO

    ND

    AT

    E

    54

    55

    F

    re

    ita

    g D

    rive

    Me

    no

    mo

    nie

    , W

    I

    54

    75

    1

    (7

    15

    )2

    35

    -3

    54

    1 P

    ho

    ne

    (7

    15

    )2

    35

    -9

    19

    0 F

    ax

    70

    5 B

    ay S

    tre

    et

    Ch

    ip

    pe

    wa

    F

    alls, W

    I

    54

    72

    9

    (7

    15

    )7

    23

    -5

    51

    1 P

    ho

    ne

    ww

    w.cfb

    si.co

    m

    PROJECT:

    DATE:

    DRAWN BY:

    REVIEWED BY:

    TH

    IS

    D

    OC

    UM

    EN

    T C

    ON

    TA

    IN

    S C

    ON

    FID

    EN

    TIA

    L A

    ND

    P

    RO

    PR

    IE

    TA

    RY

    IN

    FO

    RM

    AT

    IO

    N T

    HA

    T C

    AN

    NO

    T B

    E

    RE

    PR

    OD

    UC

    ED

    O

    R D

    IV

    UL

    GE

    D, IN

    W

    HO

    LE

    O

    R IN

    P

    AR

    T, W

    IT

    HO

    UT

    W

    RIT

    TE

    N A

    UT

    HO

    RIZ

    AT

    IO

    N F

    RO

    M C

    FB

    SI

    PR

    OP

    OS

    ED

    B

    UIL

    DIN

    G

    PIN

    E &

    P

    AL

    M H

    OL

    DIN

    GS

    L

    LC

    BU

    IL

    DIN

    G S

    EC

    TIO

    N &

    D

    ET

    AIL

    S

    19-029

    4/16/2019

    MDM

    CGR

    A300

    1

    1F

    OR

    S

    TA

    TE

    A

    PP

    RO

    VA

    L6/6/2019

    BUILDING SECTION

    1/8"=1'-0"

    2

    A100

    15" MIN. 5" MAX.

    36" M

    AX

    .

    8" MIN.

    27" M

    IN

    .

    9" M

    IN

    .

    6" MAX.

    SPOUT HEIGHT

    EQUIPMENT PERMITTED

    IN SHADED AREA

    12" MIN.

    29" M

    IN

    .

    34" M

    AX

    .

    40" M

    AX

    .

    18"

    40"

    34"

    28"

    17"-19"

    7"-9"

    42" MIN.

    40"

    12" MAX.

    36" MIN.

    16"-18"

    54" MIN.

    1 1/2" DIA. GRAB BAR TYP.

    1 1/2" DIA. GRAB BAR TYP.

    TP HOLDER

    TOILET ROOM DETAIL

    3/4"=1'-0"

    TOILET ROOM DETAIL

    3/4"=1'-0"

    DRINKING FOUNTAIN DETAIL

    3/4"=1'-0"

    RESTROOM

    60"

    8"

    MAX

    TOILET ROOM SIGN

    3/4"=1'-0"

    15" MIN.

  • 25'-0"

    120'-0"

    250'-0"

    25'-0"25'-0"25'-0"25'-0"25'-0"25'-0"25'-0"25'-0"25'-0"

    20'-0"

    20'-0"

    20'-0"

    20'-0"

    20'-0"

    20'-0"

    F

    E

    D

    C

    B

    A

    G

    1 2 3 4 5 6 7 8 9 10 11

    1

    S101

    4

    S101

    3

    S101

    F1

    F2

    F2

    F2

    F2

    F2

    P1

    P1

    P2

    P2

    P2

    P2

    P2

    F1

    D1

    D2

    D1

    D1

    D1

    D1

    D3

    D4

    5

    S101

    6

    S101

    D3

    D3

    D3

    D3

    D3

    D3

    D3

    D3

    D3

    D3

    D3

    D3

    D3

    D3

    D3

    D3

    D3

    D1

    F1

    F2

    F2

    F2

    F2

    F2

    P1

    P1

    P2

    P2

    P2

    P2

    P2

    F1

    D1

    D2

    D1

    D1

    D1

    D1

    D1

    F3P2

    2

    S101

    F4

    D4

    D4

    D4

    D4

    D4

    D4

    D4

    D4

    D4

    D4

    D4

    D4

    D4

    D4

    D4

    D4

    D4

    7

    S101

    9

    S101

    8

    S101

    2'-6"

    1'-0"

    1'-0"

    1'-6"

    F3P2F3P2F3P2F3P2F3P2F3P2F3P2F3P2

    F3P2F3P2F3P2F3P2F3P2F3P2F3P2F3P2F3P2

    F4 F4 F4 F4 F4 F4 F4 F4

    F4 F4 F4 F4 F4 F4 F4 F4 F4

    1'-6"

    #

    4

    H

    A

    I

    R

    P

    I

    N

    S

    T

    Y

    P

    .

    60°

    1

    5

    '

    -

    0

    "

    5'-0"

    MIN.

    5'-0

    "

    MIN

    .

    1'-6"

    MIN.

    6" CONC. SLAB w/6x6 -10/10 WWM

    SLOPE SLAB AWAY FROM BUILDING

    THRESHOLD HEIGHT 1/2" MAX.

    SLAB @ EXTERIOR DOORS

    3/4"=1'-0"

    4

    S100

    UNCOATED REBAR

    BAR# LAP

    3 20"

    4 24"

    5 30"

    6 36"

    7 54"

    8 62"

    LA

    P

    1/2" DIA. X 32" LONG DOWELS

    @ 3'-0" O.C. GREASE ONE END

    SAWCUT DEPTH TO BE DETERMINED

    BY GENERAL CONTRACTOR

    FORMED CONTROL JOINT

    SAWCUT CONTROL JOINT

    Bar Size and Type Minimum Diameter

    of Bend, D

    A

    No. 3 (M #10) through

    No. 8 (M #25) Grade 6 bar diameters

    50 (Grade 300) or

    Grade 60 (Grade 420)

    A

    Does not apply to stirrups or ties.

    D

    Standard 90° Hook

    FLOOR JOINTS2

    S100

    ACI HOOKS & LAP SCHEDULE3

    S100

    1 1/2" EXTRUDED POLYSTYRENE

    INSULATION, R-7.5 UNDER SLAB

    REVISION:

    PR

    OJE

    CT

    N

    AM

    E

    CL

    IE

    NT

    N

    AM

    E

    RE

    VD

    ES

    CR

    IP

    TIO

    ND

    AT

    E

    54

    55

    F

    re

    ita

    g D

    rive

    Me

    no

    mo

    nie

    , W

    I

    54

    75

    1

    (7

    15

    )2

    35

    -3

    54

    1 P

    ho

    ne

    (7

    15

    )2

    35

    -9

    19

    0 F

    ax

    70

    5 B

    ay S

    tre

    et

    Ch

    ip

    pe

    wa

    F

    alls, W

    I

    54

    72

    9

    (7

    15

    )7

    23

    -5

    51

    1 P

    ho

    ne

    ww

    w.cfb

    si.co

    m

    PROJECT:

    DATE:

    DRAWN BY:

    REVIEWED BY:

    TH

    IS

    D

    OC

    UM

    EN

    T C

    ON

    TA

    IN

    S C

    ON

    FID

    EN

    TIA

    L A

    ND

    P

    RO

    PR

    IE

    TA

    RY

    IN

    FO

    RM

    AT

    IO

    N T

    HA

    T C

    AN

    NO

    T B

    E

    RE

    PR

    OD

    UC

    ED

    O

    R D

    IV

    UL

    GE

    D, IN

    W

    HO

    LE

    O

    R IN

    P

    AR

    T, W

    IT

    HO

    UT

    W

    RIT

    TE

    N A

    UT

    HO

    RIZ

    AT

    IO

    N F

    RO

    M C

    FB

    SI

    PR

    OP

    OS

    ED

    B

    UIL

    DIN

    G

    PIN

    E &

    P

    AL

    M H

    OL

    DIN

    GS

    L

    LC

    FO

    UN

    DA

    TIO

    N P

    LA

    N

    19-029

    4/16/2019

    MDM

    CGR

    S100

    1

    1F

    OR

    S

    TA

    TE

    A

    PP

    RO

    VA

    L6/6/2019

    FOUNDATION PLAN

    1/16"=1'-0"

    1

    S100

    FOOTING SCHEDULE

    MARK SIZE & REINFORCING

    F1 3'-0"x3'-0"x1'-0" DEEP w/(4) #4 EACH WAY BOTTOM

    F2 3'-6"x3'-6"x1'-0" DEEP w/(4) #4 EACH WAY BOTTOM

    F3 4'-6"x4'-6"x1'-0" DEEP w/(5) #4 EACH WAY BOTTOM

    F4 6'-6"x6'-6"x1'-6" DEEP w/(7) #5 EACH WAY BOTTOM

    PIER SCHEDULE

    MARK SIZE REINFORCING

    P1 16"x16" C.I.P. (4) #6 VERT. & #4 TIES @ 12" O.C.

    P2 16"x16" C.I.P. (4) #6 VERT. & #4 TIES @ 12" O.C.

  • 1'-4"8"

    3'-0"

    1'-4" 1'-8"

    4- #6 VERTICALS w/STD. HOOKS

    #4 HORIZONTALS @ 12" O.C.

    8"

    2" EXTRUDED POLYSTYRENE

    INSULATION, R-10

    FOOTING DETAIL

    3/4"=1'-0"

    1

    S101

    3'-0"

    3"

    1'-0"

    3'-6"

    3" 3"2'-6"

    8"

    2" EXTRUDED POLYSTYRENE

    INSULATION, R-10

    4- #6 VERTICALS w/STD. HOOKS

    #4 HORIZONTALS @ 12" O.C.

    6"

    4- #4 BOTH WAYS @ 10" O.C.

    (4) 3/4"x18" GR36 ANCHOR RODS

    1'-4"

    6" CONCRETE SLAB

    GRADE

    FOOTING DETAIL

    3/4"=1'-0"

    2

    S101

    3'-6"

    3"

    1'-0"

    3'-6"

    3" 3"3'-0"

    8"

    2" EXTRUDED POLYSTYRENE

    INSULATION, R-10

    4- #6 VERTICALS w/STD. HOOKS

    #4 HORIZONTALS @ 12" O.C.

    6"

    4- #4 BOTH WAYS @ 12" O.C.

    (4) 3/4"x18" GR36 ANCHOR RODS

    1'-4"

    6" CONCRETE SLAB

    GRADE

    FOOTING DETAIL

    3/4"=1'-0"

    3

    S101

    FOOTING DETAIL

    3/4"=1'-0"

    4

    S101

    4'-6"

    3"

    1'-0"

    3'-6"

    3" 3"4'-0"

    8"

    2" EXTRUDED POLYSTYRENE

    INSULATION, R-10

    4- #6 VERTICALS w/STD. HOOKS

    #4 HORIZONTALS @ 12" O.C.

    6"

    5- #4 BOTH WAYS @ 12" O.C.

    (4) 3/4"x18" GR36 ANCHOR RODS

    1'-4"

    6" CONCRETE SLAB

    GRADE

    3"

    3"

    3"

    6"

    1'-6"

    4-3/4" x 18" ANCHOR RODS

    FOOTING DETAIL

    3/4"=1'-0"

    5

    S101

    6'-6"

    7- #5 @ 12" BOTH WAYS

    2'-0"

    1'-0"

    3'-6"

    3" 3"1'-6"

    2- #4's CONTINUOUS

    #5 VERTICALS @ 1'-4" O.C.

    #5 HORIZONTALS @ 1'-0" O.C.

    6"

    6" CONCRETE SLAB

    3"

    8"

    2" EXTRUDED POLYSTYRENE

    INSULATION, R-10

    GRADE

    2"

    3'-0" N.T.S. 8"

    #5 TIES SPACED @ 2'-0" O.C.

    VERIFY EDGE CONDITION AND

    PROVIDE STEEL ANGLE FOR EDGE

    OF DOCK LEVELER

    2'-0"

    1'-0"

    3'-6"

    3" 3"1'-6"

    2- #4's CONTINUOUS

    #5 VERTICALS @ 1'-4" O.C.

    #5 HORIZONTALS @ 1'-0" O.C.

    6"

    6" CONCRETE SLAB

    FOOTING DETAIL

    3/4"=1'-0"

    6

    S101

    3"

    2" EXTRUDED POLYSTYRENE

    INSULATION, R-10

    4'-0"

    PIER DETAIL

    3/4"=1'-0"

    7

    S101

    8

    S101

    9

    S101

    PIER DETAIL

    3/4"=1'-0"

    PIER DETAIL

    3/4"=1'-0"

    1'-4"

    8"

    3'-0"

    1'-4"

    1'-8"

    8"

    4- #6 VERTICALS w/STD. HOOKS

    #4 HORIZONTALS @ 12" O.C.

    2" EXTRUDED POLYSTYRENE

    INSULATION, R-10

    1'-4"8"8"

    1'-4"

    3'-6"

    1'-1"

    1'-1"

    3'-6"

    10"2'-8"

    4- #6 VERTICALS w/STD. HOOKS

    #4 HORIZONTALS @ 12" O.C.

    2" EXTRUDED POLYSTYRENE

    INSULATION, R-10

    1'-4"

    8"

    8"

    1'-4"

    4'-6"

    1'-7"1'-7"

    4'-6"

    1'-10"

    2'-8"

    8" 8"10" 8"1'-10"

    8" 8"

    4"

    8"

    REVISION:

    PR

    OJE

    CT

    N

    AM

    E

    CL

    IE

    NT

    N

    AM

    E

    RE

    VD

    ES

    CR

    IP

    TIO

    ND

    AT

    E

    54

    55

    F

    re

    ita

    g D

    rive

    Me

    no

    mo

    nie

    , W

    I

    54

    75

    1

    (7

    15

    )2

    35

    -3

    54

    1 P

    ho

    ne

    (7

    15

    )2

    35

    -9

    19

    0 F

    ax

    70

    5 B

    ay S

    tre

    et

    Ch

    ip

    pe

    wa

    F

    alls, W

    I

    54

    72

    9

    (7

    15

    )7

    23

    -5

    51

    1 P

    ho

    ne

    ww

    w.cfb

    si.co

    m

    PROJECT:

    DATE:

    DRAWN BY:

    REVIEWED BY:

    TH

    IS

    D

    OC

    UM

    EN

    T C

    ON

    TA

    IN

    S C

    ON

    FID

    EN

    TIA

    L A

    ND

    P

    RO

    PR

    IE

    TA

    RY

    IN

    FO

    RM

    AT

    IO

    N T

    HA

    T C

    AN

    NO

    T B

    E

    RE

    PR

    OD

    UC

    ED

    O

    R D

    IV

    UL

    GE

    D, IN

    W

    HO

    LE

    O

    R IN

    P

    AR

    T, W

    IT

    HO

    UT

    W

    RIT

    TE

    N A

    UT

    HO

    RIZ

    AT

    IO

    N F

    RO

    M C

    FB

    SI

    PR

    OP

    OS

    ED

    B

    UIL

    DIN

    G

    PIN

    E &

    P

    AL

    M H

    OL

    DIN

    GS

    L

    LC

    FO

    UN

    DA

    TIO

    N D

    ET

    AIL

    S

    19-029

    4/16/2019

    MDM

    CGR

    S101

    1

    1F

    OR

    S

    TA

    TE

    A

    PP

    RO

    VA

    L6/6/2019

    PINE AND PALM ARCH 6-7-19Sheets and ViewsA000-ARCH DA100-A100A100-A200A100-A300A100-S100A100-S101

    Somerset - Pine Palm Civil Plan Set - FINALEXISTING SITE CONDITIONSSITE PLANGRADING PLANEROSION CONTROL PLANUTILITY PLANDETAIL (1)DETAIL (2)