pi-berlin.com PI Berlin LeTID for Investors · PI Test Protocol Part of PI Quality Package Initial...

11
PI Berlin – LeTID for Investors The leading technical advisor, risk manager and quality assurance provider for PV power plants and equipment ©2019 PI Photovoltaik-Institut Berlin AG | JMarch 2019 pi-berlin.com

Transcript of pi-berlin.com PI Berlin LeTID for Investors · PI Test Protocol Part of PI Quality Package Initial...

Page 1: pi-berlin.com PI Berlin LeTID for Investors · PI Test Protocol Part of PI Quality Package Initial Pmax at STC, EL Optional: LID stabilisation 50°C (IEC) Forward bias current I=

PI Berlin – LeTID for InvestorsThe leading technical advisor, risk manager and quality assurance provider for PV power plants and equipment

©2019 PI Photovoltaik-Institut Berlin AG | JMarch 2019

pi-berlin.com

Page 2: pi-berlin.com PI Berlin LeTID for Investors · PI Test Protocol Part of PI Quality Package Initial Pmax at STC, EL Optional: LID stabilisation 50°C (IEC) Forward bias current I=

©2019 PI Photovoltaik-Institut Berlin AG | March 2019

LeTID on PERC Modules

F.

Ke

rste

ne

t a

l., 3

1stE

UP

VS

EC

20

15

-1%

-7%

-> Grid connected PV plants will degrade over several years and then regenerate

over several years depending on the PERC cell process

Page 3: pi-berlin.com PI Berlin LeTID for Investors · PI Test Protocol Part of PI Quality Package Initial Pmax at STC, EL Optional: LID stabilisation 50°C (IEC) Forward bias current I=

©2019 PI Photovoltaik-Institut Berlin AG | March 2019

Light and Temperature Dependence of LeTID

Acceleration factor ≈ 2 by every 10°C temperature step

Acceleration factor ≈ 6 for Open Circuit Modus (I = Isc) against load Modes (I< Isc)

Carrier injection by Light and Current roughly equivalent (LID ≈ CID)

F.

Ke

rste

ne

t a

l., 3

1stE

UP

VS

EC

20

15

Page 4: pi-berlin.com PI Berlin LeTID for Investors · PI Test Protocol Part of PI Quality Package Initial Pmax at STC, EL Optional: LID stabilisation 50°C (IEC) Forward bias current I=

©2019 PI Photovoltaik-Institut Berlin AG | March 2019

How to differentiate between LeTID and normal LID?

K.

Mo

rita

et

al., W

CP

EC

-3 2

003

A.

Herg

uth

et

al. S

ilicon

PV

20

17

LeTIDLID

* via light or current

LeTID LID

Time Scale Years Hours

Recovery (field) Carrier Injection* + Heat Heat

Magnitude 4% - 10% 1% -3%

Page 5: pi-berlin.com PI Berlin LeTID for Investors · PI Test Protocol Part of PI Quality Package Initial Pmax at STC, EL Optional: LID stabilisation 50°C (IEC) Forward bias current I=

Mechanism behind LeTID still not clarified

5

Non-gettered metals?

Mobile hydrogen?

©2019 PI Photovoltaik-Institut Berlin AG | March 2019

Page 6: pi-berlin.com PI Berlin LeTID for Investors · PI Test Protocol Part of PI Quality Package Initial Pmax at STC, EL Optional: LID stabilisation 50°C (IEC) Forward bias current I=

How to overcome LeTID?

Fast Anneal (< 1min) in the cell production > 2 sun irradiation, T > 270°C

Forward bias at module in the laminator 150°-170°C, 10- 20 min (left)

Eight weeks field anneal during summer under open circuit in Korea (right)

K.

Le

e e

t a

l.,

31

stE

UP

VS

EC

20

15

K. L

ee

et a

l., 31

stE

UP

VS

EC

20

15

©2019 PI Photovoltaik-Institut Berlin AG | March 2019

Page 7: pi-berlin.com PI Berlin LeTID for Investors · PI Test Protocol Part of PI Quality Package Initial Pmax at STC, EL Optional: LID stabilisation 50°C (IEC) Forward bias current I=

PI Test Protocol

Part of PI Quality Package

Initial Pmax at STC, EL

Optional: LID stabilisation 50°C (IEC)

Forward bias current

I= 0.5A, 2.0A, 5.0A, 10A

75°C for 168h (2 modules each).

Pmax, EL after 2h, 24h, 48h,

72h, 96h,120h,144h and 168h

Pass: ΔPmax Power loss < 2% after 168h

Similar to CD IEC 61215-2 Ed. 2 (under discussion): slow and fast degradation/reneration mode

Slow: LeTID Detection, repeat 162h, I = Isc-Impp, 75°C until ΔPmax < 1% (MQT 23.1 )

Fast: LeTID Regeneration, repeat 500h, I = Isc, 85°C until ΔPmax < 1% (MQT 23.2)

PI B

erlin

©2019 PI Photovoltaik-Institut Berlin AG | March 2019

Page 8: pi-berlin.com PI Berlin LeTID for Investors · PI Test Protocol Part of PI Quality Package Initial Pmax at STC, EL Optional: LID stabilisation 50°C (IEC) Forward bias current I=

Climate chamber test

8

= Isc-Impp Mode

10A = Voc Mode

A slow LeTID detection method is recommended, e.g. I= Isc-Impp = 0,5A

Degradation might be missed completely, when testing is to fast and to close

to Voc Mode = lowest row in the EL images (right)

PI B

erlin

=Voc

©2019 PI Photovoltaik-Institut Berlin AG | March 2019

Page 9: pi-berlin.com PI Berlin LeTID for Investors · PI Test Protocol Part of PI Quality Package Initial Pmax at STC, EL Optional: LID stabilisation 50°C (IEC) Forward bias current I=

Benchmarking Mono vs. multi PERC on LeTID

9

multi 10 PERC modules 75°C

I = Isc-Impp

(2x multi, 8x mono)

No clear sign, that mono

PERC performs better,

e.g. see Ramspeck 2012

Maybe because multi

PERC producers were

earlier alerted and already

deployed sufficient

counter-measures

PI B

erlin

©2019 PI Photovoltaik-Institut Berlin AG | March 2019

Page 10: pi-berlin.com PI Berlin LeTID for Investors · PI Test Protocol Part of PI Quality Package Initial Pmax at STC, EL Optional: LID stabilisation 50°C (IEC) Forward bias current I=

Field Results

10

Lab-to-field comparision:

1200 h, I = Isc-Impp, 75°C in the climate chamber equals 4 years in the field:

-7% power loss in Cyprus (for non-stabilized multi PERC cells)

-2,5% power loss 4 years in Germany (ditto)

But only -1% each with LeTID-stable PERC process

PI customer feed-back from the field:

-5% in energy yield in semi-arid regions with up to -15% power loss by LeTID

after two years on single multi PERC modules from 2016

-> Results on LeTID are also very slow

©2019 PI Photovoltaik-Institut Berlin AG | March 2019

Page 11: pi-berlin.com PI Berlin LeTID for Investors · PI Test Protocol Part of PI Quality Package Initial Pmax at STC, EL Optional: LID stabilisation 50°C (IEC) Forward bias current I=