description

Physical Transmission Media. 8. Objectives. In this chapter, you will learn to: Characteristics of wireline transmission Properties and uses of coaxial cable Properties and uses of different types of twisted-pair wire Characteristics of lightwave transmission - PowerPoint PPT Presentation

Transcript of Physical Transmission Media

Page 1: Physical Transmission Media

Physical Transmission Media

8

04/22/231 Modified by: Brierley

Page 2: Physical Transmission Media

Objectives

In this chapter, you will learn to:

Characteristics of wireline transmission Properties and uses of coaxial cable Properties and uses of different types of twisted-pair wire Characteristics of lightwave transmission Properties and uses of fiber optic cable Factors to consider when selecting a telecommunications medium Cabling standards Installing wire and fiber optic cabling Testing continuity and performance on physical transmission

media

04/22/232 Modified by: Brierley

Page 3: Physical Transmission Media

Characteristics of Wireline Transmission

Impedance: expressed in Ohms, is the combined effect of a circuit’s inductance and capacitance.

Propagation Delay and Latency: the difference in time between a data packet’s transmission and its reception over a specific route.

Distortion: the unintended and undesirable modification of at least one signal component, which makes the signal different from how it was originally transmitted.

Noise: any unwanted interference from external sources.

04/22/233 Modified by: Brierley

Page 4: Physical Transmission Media

Crosstalk

04/22/234 Modified by: Brierley

Page 5: Physical Transmission Media

Impulse Noise

04/22/235 Modified by: Brierley

Page 6: Physical Transmission Media

Thermal Noise

04/22/236 Modified by: Brierley

Page 7: Physical Transmission Media

Coaxial Cable

04/22/237 Modified by: Brierley

Page 8: Physical Transmission Media

Non-twisted Wire

04/22/238 Modified by: Brierley

Page 9: Physical Transmission Media

Level 1 Terminations

04/22/239 Modified by: Brierley

Page 10: Physical Transmission Media

Twisted Pair (TP)

04/22/2310 Modified by: Brierley

Page 11: Physical Transmission Media

Shielded Twisted Pair (STP)

04/22/2311 Modified by: Brierley

Page 12: Physical Transmission Media

Unshielded Twisted Pair (UTP)

04/22/2312 Modified by: Brierley

Page 13: Physical Transmission Media

Category 5 (CAT5)

04/22/2313 Modified by: Brierley

Page 14: Physical Transmission Media

Category 3 (CAT3)

04/22/2314 Modified by: Brierley

You describe and draw

Page 15: Physical Transmission Media

Fiber Optic Cable

04/22/2315 Modified by: Brierley

Page 16: Physical Transmission Media

Fiber Optic Cable

04/22/2316 Modified by: Brierley

Page 17: Physical Transmission Media

Popular Uses for Fiber Optic Cable

Includes connecting:

Regional and local cable TV facilities Internet NAPs with other large

telecommunications exchange point Central offices with other central offices Main feeders with central offices A telecommunication’s network with private LANs A telecommunication’s network with private

switching systems, such as PBX

04/22/2317 Modified by: Brierley

Page 18: Physical Transmission Media

Selecting Appropriate Media

When selecting telecommunications media consider:

Existing infrastructure Throughput potential Cost of installation Noise immunity Security Size and scalability

04/22/2318 Modified by: Brierley

Page 19: Physical Transmission Media

Comparison of Physical Media

04/22/2319 Modified by: Brierley

Page 20: Physical Transmission Media

Comparison of Physical Media

04/22/2320 Modified by: Brierley

Page 21: Physical Transmission Media

Structured Cabling

04/22/2321 Modified by: Brierley

Page 22: Physical Transmission Media

Backbone Wiring

04/22/2322 Modified by: Brierley

Page 23: Physical Transmission Media

Telecommunications Closet

04/22/2323 Modified by: Brierley

Page 24: Physical Transmission Media

Telecommunications Closet

04/22/2324 Modified by: Brierley

Page 25: Physical Transmission Media

Horizontal Wiring

04/22/2325 Modified by: Brierley

Page 26: Physical Transmission Media

Work Area

04/22/2326 Modified by: Brierley

Page 27: Physical Transmission Media

Work Area

04/22/2327 Modified by: Brierley

Page 28: Physical Transmission Media

Installing UTP

04/22/2328 Modified by: Brierley

Page 29: Physical Transmission Media

Crossover Cable

04/22/2329 Modified by: Brierley

Page 30: Physical Transmission Media

Installation Tips for CAT5 UTP

Do not untwist twisted-pair cables more than one-half inch before inserting them into the punch-down block or connector.

Pay attention to the bend radius limitations for the type of cable you are installing.

Test each segment of cabling as you install it with a cable tester.

Use only cable ties to cinch groups of cables together04/22/2330 Modified by: Brierley

Page 31: Physical Transmission Media

Installation Tips for CAT5 UTP

When pulling cable, do not exert more than 25 pounds of pressure on the cable.

Avoid laying cable across the floor where it might sustain damage from rolling chairs or foot traffic.

Install cable at least three feet away from fluorescent lights or other sources of EMI.

Always leave slack in cable runs.

04/22/2331 Modified by: Brierley

Page 32: Physical Transmission Media

Installing Fiber

Splice - the physical joining of two facing and aligned pieces of wire or fiber.

Mechanical splicing - the two ends of a fiber optic cable are fixed in position within a tube so that they form one continuous communications channel.

Fusion splicing - a connection between fibers is accomplished through the application of heat and the resulting melting and fusion of two fiber strands.

04/22/2332 Modified by: Brierley

Page 33: Physical Transmission Media

Mechanical and Fusion Splicing

04/22/2333 Modified by: Brierley

Page 34: Physical Transmission Media

ST and SC Fiber Connectors

04/22/2334 Modified by: Brierley

Page 35: Physical Transmission Media

Cable Installation Tips for Fiber Optic Cable

When pulling fiber optic cable, do not exert pressure on the cable.

Fiber optic cable should be installed within a conduit whenever you are concerned about the potential for environmental damage.

Do not exceed the minimum bend radius.

04/22/2335 Modified by: Brierley

Page 36: Physical Transmission Media

Troubleshooting Connectivity Problems

Identify the symptoms Identify the scope of the problem Establish what has changed on the network Determine the most probable cause of the

problem Implement a solution Test the solution Recognize the potential effects of the solution Document the solution

04/22/2336 Modified by: Brierley

Page 37: Physical Transmission Media

Troubleshooting Tools

Crossover Cable - allows you to quickly and easily verify that a node’s network adapter is transmitting and receiving signals properly.

Tone Generator - a small electronic device that issues a signal on a wire pair.

Tone Locator - a type of amplifier that can detect the inductive energy emitted by the tone (current) on a wire.

04/22/2337 Modified by: Brierley

Page 38: Physical Transmission Media

Tone Generator and Tone Locator

04/22/2338 Modified by: Brierley

Page 39: Physical Transmission Media

Performance Testers

Provides the following functions:

Measures the length of each wire pair Ensures that the cable does not exceed

recommended maximum lengths Measures the distance from the tester to a

cable fault Measures attenuation along a cable Measures crosstalk between wires

04/22/2339 Modified by: Brierley

Page 40: Physical Transmission Media

Performance Testers

04/22/2340 Modified by: Brierley

Page 41: Physical Transmission Media

Fiber Optic Cable Testers

04/22/2341 Modified by: Brierley

Page 42: Physical Transmission Media

Time Domain Reflectometers

04/22/2342 Modified by: Brierley

Page 43: Physical Transmission Media

Telephone Test Set

04/22/2343 Modified by: Brierley

Page 44: Physical Transmission Media

Summary

Characteristics that affect wireline transmission include impedance changes, latency, delay distortion, and noise.

Traditional four-pair, non-twisted copper telephone wiring is known as Level 1 cable or quad wire.

Category (CAT3) UTP cable is the minimum grade of unshielded twisted-pair cabling for use in telephone systems.

To identify the source of cabling infrastructure problems, follow a logical troubleshooting methodology and have the appropriate testing tools handy.

04/22/2344 Modified by: Brierley