Photon Infrared Beams Pocket Installation Guide infrared beams manual ins… · 5. Technical...
Transcript of Photon Infrared Beams Pocket Installation Guide infrared beams manual ins… · 5. Technical...
Photon Infrared Beams Pocket Installation Guide
SAFETY BEAMS FOR
AUTOMATED GATES
1. Introduction
3. Icons used in this guide
This icon indicates warning, caution or attention! Please take special note of critical aspects that MUST be adhered to in order to prevent injury
When connected to an automated system such as a gate motor or garage door operator, the Photon beams aid in preventing personal injury, and/or property damage due to crushing, when used in a closing beam configuration. When used in an opening beam configuration, the Photon beams dramatically reduce the hazardous actions associated with a gate that is opening; such as dragging or shearing. The operation of the Photon beams relies upon the infrared beam being interrupted by a person or object, and notifying a device connected to its fail-safe contact, of the interruption.
In addition, Photon beams are compatible with the unique Intruder-detection Alarm functionality inherent in some of CENTURION’s gate operators. These operators allow the Photon beams to act as sophisticated perimeter security devices by activating an alarm on the operator’s controller, or a third-party alarm system, whenever the beams have been obstructed or remain obstructed for a predefined period of time.
Refer to the relevant product documentation for further information about Intruder-detection Alarm functionality.
4. Operation
1. All installation, repair, and service work to this product must be done by a suitably qualified person.
2. Do not in any way modify the components of the system.
3. Do not leave packing materials (plastic, polystyrene, etc.) within reach of children as such materials are potential sources of danger.
4. Dispose of all waste products like packaging materials, according to local regulations.
5. CENTURION does not accept any liability caused by improper use of the product, or for use other than that for which the automated system was intended.
6. This product was designed and built strictly for the use indicated in this documentation. Any other use, not expressly indicated here, could compromise the service life/operation of the product and/or be a source of danger.
7. Anything not expressly specified in these instructions is not permitted.
This icon denotes variations and other aspects that should be considered during installation
Photon infrared gate safety beams have been designed to provide an integral element of safety to an automated system while at the same time affording the installer considerable freedom during the installation process. The transmitter is completely wireless – being powered via two AA Alkaline batteries – obviating the need for tunnelling and digging and subsequent defacement of one’s driveway for the purpose of running cables. Not only does this arrangement allow for significant flexibility and fewer restrictions when it comes to mounting the beams, but it dramatically reduces material and labour costs.
2. Safety Instructions
5. Technical specifications
Power supply Transmitter: 2 x AA Alkaline batteries (supplied)
Receiver: 12V – 24V AC 12V – 30V DC
Only replace with alkaline batteries; do not use rechargeable batteries with this productCircular area – assuming a parallel surfaceSelectable by jumper
Power consumption
Transmitter battery life
Battery low indication
Maximum operating distance
Alignment
Output contact
Output contact rating
Operating temperature
Operating humidity
Housing material
Degree of protection
Receiver: 30mA @ 12V DC (relay)
15mA @ 12V DC (open collector)
Minimum of two years
Audible beep
10m
Automatic – 1m² @ 10m
Fail safe, N/C and N/O potential-free,
N/C open collector
3A @ 30V DC non-inductive/
50mA @ 30V DC (open collector)
-15°C - +65°C
0 - 90° non-condensing
ABS
IP54
6. Installation
The transmitter has been fitted with a ‘power up’ jumper. In order to preserve battery life, the unit has been packed with the jumper in the OFF position; to power up the transmitter, simply position the jumper so that it is bridging the ON and COMMON pins as illustrated
Power
ON
OFF
Jumperat ‘OFF’
Power
ON
OFF
Power
ON
OFF
Jumperat ‘ON’
Power
ON
OFF
Installer Mode
1. To enter Installer Mode, press and hold the pushbutton on the receiver for a period of one second. The buzzer will emit two beeps to indicate the transition into Installer Mode
Installer Mode is a unique feature that facilitates the alignment of the beams by providing audible feedback via the receiver’s onboard buzzer.
Once in Installer Mode, the LED will illuminate permanently, while the IR beam signal is not being received by the receiver.
2. Next, proceed with the alignment of the beams, noting the behaviour of the receiver; as soon as the beams are suitably aligned, the LED will switch off and the buzzer will emit a continuous 4KHz tone.
The transmitter will remain in Installer Mode for a period of 120 seconds, but an early exit may be invoked by momentarily pressing the pushbutton.
Remove cover and prepare for mounting
6. Lift off cover as shown in the illustration.
Screw-hole cover
Fastener
Cover
Mounting hole
Screw-hole
There is no need to remove the PCB when mounting the Photon. The mounting hole is easily accessible making mounting quick and easy
4. Unclip screw-hole cover piece.
5. Unscrew cover retaining fastener.
750mm
Position receiver and transmitter so that they are in line and levelwith each other
Rx Tx
Centurion Systems recommends the height of 750mm, but the height of the beam must be tailored to suit the specific requirements of the installation.
3. The first step when installing the Photon infrared beams is to obtain optimal alignment. Ensure that covers are fitted before beginning alignment
! The transmitter and receiver are typically mounted directly opposite one another, but some leeway is given in the form of a wide beam being cast should absolute alignment not be possible
! It is of paramount importance that the beams are mounted on surfaces that are reasonably parallel to one another. Small differences in the angle between the opposing parallel surfaces can lead to large offsets between the transmitter and the receiver alignment of the beams - the greater the distance the infrared beam travels between the transmitter and the receiver, the larger the offset
Beam Alignment
The beam lenses MUST be fitted during the alignment procedure as they serve to focus the infrared beam. Failure to do so may result in an inability to achieve alignment.
! For ease of alignment, an onboard buzzer has been provided on the receiver, that can be activated by placing the Photon receiver unit in Installer Mode, described in the relevant section
GND
12-24V DC/AC
COM
NC
NO
RedLED
Receiver
PCB connections
12. The receiver’s relay can then be connected to the input of an external device using either the normally-open or normally-closed contact shown in the wiring diagram.
13. Test the operation of the Photon infrared beams by passing an object such as your hand through the beam; there should be an audible ‘click’ to indicate that the internal relay is being de-energised. If the beams have been connected to an automated system, the operator should immediately halt movement when the beams are obstructed.
Receiver
ON
OFF
RedLED
Alkaline batteries
Transmitter
Wiring route
11. Break out the relevant knockouts and route the cables through the cable cut-out as shown in the illustration, providing 12V - 24V AC or 12V - 30V DC to the receiver.
Cut-outfor cable
Cable
If Open Collector is used, there will not be a “click”
Mounting
7. Mark position of receiver unit.
8. Use 5mm masonry bit to drill hole in wall.
9. Mount using fastener provided.
10. Repeat the same mounting procedure when mounting the transmitter unit.
‘O’ Ring
Fastener
Height - typically 750mm above the ground
Rawl plug
Double wireless closing safety beams connection to D-Series controller
IRB Receiver
IRB Receiver
12V/24V
12V/24V
COM
COM
N/C
N/C
N/O
N/O
12V/24V
12V/24V
WirelessIRB
Transmitter
WirelessIRB
Transmitter
Wireless opening safety beamsconnection to D-Series controller
IRB Receiver
12V/24V
COM
N/C
N/O
12V/24V
WirelessIRB
Transmitter
! The red LED will flash five times on power-up, to indicate the unit is powering up correctly.
! In Normal Mode of Operation, the red LED will flash briefly, once every second, while the IR beam signal is not detected (i.e. While the IR beam is obstructed).
! In Installer Mode, the red LED will remain on, while the IR beam signal is not detected (i.e. While the IR beam is obstructed).
! The red LED will remain off in both modes, if the beam signal is detected
IndicatorsThe receiver has been fitted with a red LED for feedback and diagnostic purposes.
! The buzzer on the transmitter PCB will emit an alarm tone when the batteries are nearing the end of their functional life. Should the user not have replacement batteries at his disposal at the time of notification, the buzzer can be disabled for a period of 24 hours by momentarily pressing the pushbutton
! The receiver buzzer will emit a continuous 4KHz tone when alignment is obtained ONLY if Installer Mode is enabled.
In addition, both the receiver and transmitter modules have been fitted with onboard buzzers, which provide the following feedback:
Open Collector ModeIn sites where current consumption is a factor, for e.g. solar-powered installations, the onboard relay can be disabled by selecting Open Collector Mode. This is accomplished by moving the jumper on the receiver from pins 2 and 3 to pins 1 and 2. The open collector output is then available on the normally-closed terminal, and will switch down to ground.
www.CentSys.com
0.07.A.0027
Sharecall 0860-CENTURION (0860 236 887)Head Office: +27 11 699 2400
Sharecall Technical Support 0861 003 123 or +27 11 699 2481
from 07h00 to 18h00 (GMT+2)
(Sharecall numbers applicable when dialled from within South Africa only)