Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor...
-
date post
19-Dec-2015 -
Category
Documents
-
view
228 -
download
2
Transcript of Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor...
![Page 1: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/1.jpg)
Phasors
ET 242 Circuit Analysis II
Electrical and Telecommunication Engineering Technology
Professor Jang
![Page 2: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/2.jpg)
AcknowledgementAcknowledgement
I want to express my gratitude to Prentice Hall giving me the permission to use instructor’s material for developing this module. I would like to thank the Department of Electrical and Telecommunications Engineering Technology of NYCCT for giving me support to commence and complete this module. I hope this module is helpful to enhance our students’ academic performance.
![Page 3: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/3.jpg)
OUTLINESOUTLINES
Psasors – Polar and Rectangular Formats
Mathematical Operations with Complex Numbers
ET 242 Circuit Analysis II – Phasors Boylestad 2
Conversion Between Forms
Key Words: Complex Number, Phasor, Time Domain, Phase Domain
![Page 4: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/4.jpg)
Mathematical Operations with Complex Numbers
Complex numbers lend themselves readily to the basic mathematical operations of addition, subtraction, multiplication, and division. A few basic rules and definitions must be understood before considering these operations.
jj
j
j
jj
j
jj
Furtheronsoand
jj
jjjwith
jjjjjand
jThus-j
1
11)1(
1
,.
1)1)(1(
1
1,1
,definitionBy
numbers,imaginarywithassociatedjsymboltheexaminefirstusLet
2
5
224
23
2
ET 242 Circuit Analysis II – Phasors Boylestad 3
![Page 5: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/5.jpg)
ET 242 Circuit Analysis II – Average power & Power Factor Boylestad 2
Complex Conjugate: The conjugate or complex conjugate of a complex number can be found by simply changing the sign of imaginary part in rectangular form or by using the negative of the angle of the polar form. For example, the conjugate of
C = 2 + j3 is 2 – j3
5414Fig.inshownas
302302C
ofconjugateThe53.14Fig.inshownas
oo is
Figure 14.53 Defining the complex conjugate of a complex number in rectangular form.
Figure 14.54 Defining the complex conjugate of a complex number in polar form.
![Page 6: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/6.jpg)
Reciprocal: The reciprocal of a complex number is 1 devided by the complex number. For example, the reciprocal of
We are now prepared to consider the four basic operations of addition, subtraction, multiplication, and division with complex numbers.
Z
Zofand
jYXisjYX
1
,
1C
Addition: To add two or more complex numbers, add the real and imaginary parts separately. For example, if
C1 = ±X1 ± jY1 and C2 = ±X2 ± jY2
then C1 + C2 = (±X1 ± X2) + j(±Y1 ± Y2)
There is really no need to memorize the equation. Simply set one above the other and consider the real and imaginary parts separately, as shown in Example 14-19.
ET 242 Circuit Analysis II – Phasors Boylestad 5
![Page 7: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/7.jpg)
Ex. 14-19 a. Add C1 = 2 + j4 and C2 = 3 + j1 b. Add C1 = 3 + j6 and C2 = –6 – j3
a. C1 + C2 = (2 + 3) + j(4 + 1) = 5 + j5
b. C1 + C2 = (3 – 6) + j(6 + 3) = –3 + j9
Figure 14.55 Example 14-19 (a) Figure 14.56 Example 14-19 (b)
ET 242 Circuit Analysis II – Phasors Boylestad 6
![Page 8: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/8.jpg)
ET 242 Circuit Analysis II – Phasors Boylestad 7
Subtraction: In subtraction, the real and imaginary parts are again considered separately. For example, if
C1 = ±X1 ± jY1 and C2 = ±X2 ± jY2
then C1 – C2 = [(±X1 – (± X2)] + j[(±Y1 – ± Y2)]
Again, there is no need to memorize the equation if the alternative method of Example 14-20 is used.
Ex. 14-20 a. Subtract C2 = 1 + j4 from C1 = 4 + j6 b. Subtract C2 = –2 + j5 from C1 = +3 + j3
a. C1 – C2 = (4 – 1) + j(6 – 4)
= 3 + j2
b. C1 – C2 = (3 – (–2)) + j(3 – 5)
= 5 – j2
Figure 14.57 Example 14-20 (a)
Figure 14.58 Example 14-20 (b)
![Page 9: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/9.jpg)
Addition or subtraction cannot be performed in polar form unless the complex numbers have the same angle θ or unless they differ only by multiples of 180°.
60.14Fig.Note.06180402b.
59.14Fig.Note.455453452a.ooo
ooo
2114Ex.
Figure 14.59 Example 14-21 (a)
Figure 14.60 Example 14-21 (b)
ET 242 Circuit Analysis II – Phasors Boylestad 8
![Page 10: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/10.jpg)
Multiplication: To multiply two complex numbers in rectangular form, multiply the real and imaginary parts of one in turn by the real and imaginary parts of the other. For example, if
C1 = X1 + jY1 and C2 = X2 + jY2
then C1 · C2 : X1 + jY1
X2 + jY2
X1X2 + jY1X2
+ jX1Y2 + j2Y1Y2
X1X2 + j(Y1X2 + X1Y2) + Y1Y2(–1)
and C1 · C2 = (X1X2 – Y1Y2) + j(Y1X2 + X1Y2)
In Example 14-22(b), we obtain a solution without resorting to memorizing equation above. Simply carry along the j factor when multiplying each part of one vector with the real and imaginary parts of the other.
ET 242 Circuit Analysis II – Phasors Boylestad 9
![Page 11: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/11.jpg)
ET 242 Circuit Analysis II – Average power & Power Factor Boylestad 2
Ex. 14-22 a. Find C1 · C2 if C1 = 2 + j3 and C2 = 5 + j10 b. Find C1 · C2 if C1 = –2 – j3 and C2 = +4 – j6
a. Using the format above, we have
C1 · C2 = [(2) (3) – (3) (10)] + j[(3) (5) + (2) (10)]
= – 20 + j35
b. Without using the format, we obtain–2 – j3 +4 – j6–8 – j12 + j12 + j218–8 + j(–12 + 12) – 18
and C1 · C2 = –26 = 26 180ے °
In polar form, the magnitudes are multiplied and the angles added algebraically. For example, for
)θ(θZZCC
writewe
θZCandθZC
212121
222111
ET 242 Circuit Analysis II – Phasors Boylestad 10
![Page 12: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/12.jpg)
o2
o121
o2
o121
1207Cand402CifCCFindb.
3010Cand205CifCCFinda.
2314Ex.
o
oo
oo21
o
oo
oo21
8014
)12040((2)(7)
)120)(740(2CCb.
5050
)30(20(5)(10)
)30)(1020(5CCa.
To multiply a complex number in rectangular form by a real number requires that both the real part and the imaginary part be multiplied by the real number. For example,
andoo jj
jj
90300300)60(050
3020)32)(10(
ET 242 Circuit Analysis II – Phasors Boylestad 11
![Page 13: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/13.jpg)
Division: To divide two complex numbers in rectangular form, multiply the numerator and denominator by the conjugate of the denominator and the resulting real and imaginary parts collected. That is, if
then
and
The equation does not have to be memorized if the steps above used to obtain it are employed. That is, first multiply the numerator by the complex conjugate of the denominator and separate the real and imaginary terms. Then divide each term by the sum of each term of the denominator square.
22
22
21122
222
2121
2
1
22
22
21122121
2222
2211
2
1
222111
)()(
))((
))((
YX
YXYXj
YX
YYXX
C
C
YX
YXYXjYYXX
jYXjYX
jYXjYX
C
C
jYXCandjYXC
ET 242 Circuit Analysis II – Phasors Boylestad 12
![Page 14: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/14.jpg)
Ex. 14-24 a. Find C1 / C2 if C1 = 1 + j4 and C2 = 4 + j5b. Find C1 / C2 if C1 = –4 – j8 and C2 = +6 – j1
j0.270.5941
11j
41
24
54
(4)(4)j
54
(4)(5)(1)(4)
C
C
equation,precedingBy.
22222
1
a
j1.410.4337
52j
37
16and
371036
1jj6
j636
j16
j16
j52168j5224
8jj4
j4824
j16
j84
obtainwemethod,ealternativanUsing.
2
1
2
2
C
C
b
ET 242 Circuit Analysis II – Phasors Boylestad 13
![Page 15: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/15.jpg)
ET 242 Circuit Analysis II – Average power & Power Factor Boylestad 14
In polar form, division is accomplished by dividing the magnitude of the numerator by the magnitude of the denominator and subtracting the angle of the denominator from that of the numerator. That is, for
we write
To divide a complex number in rectangular form by a real number, both the real part and the imaginary part must be divided by the real number. For example,
andoj
j
jj
04.304.32
08.6
542
108
)( 212
1
2
1
222111
Z
Z
C
C
ZCandZC
o2
o121
o2
o121
501Cand8CifCCFindb.
72Cand101CifCCFinda.
6120/
5/
2514Ex.
oooo
o
oooo
o
C
Cb
C
Ca
1705.0))50(120(16
8
5016
1208.
35.7)710(2
15
72
1015.
2
1
2
1
![Page 16: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/16.jpg)
Figure 14.71 Adding two sinusoidal waveforms on a point-by-point basis.
PhasorsThe addition of sinusoidal voltages and current is frequently required in the analysis of ac circuits. One lengthy but valid method of performing this operation is to place both sinusoidal waveforms on the same set of axis and add a algebraically the magnitudes of each at every point along the abscissa, as shown for c = a + b in Fig. 14-71. This, however, can be a long and tedious process with limited accuracy.
ET 242 Circuit Analysis II – Phasors Boylestad 15
![Page 17: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/17.jpg)
A shorter method uses the rotating radius vector. This radius vector, having a constant magnitude (length) with one end fixed at the origin, is called a phasor when applied to electric circuits. During its rotational development of the sine wave, the phasor will, at the instant = 0, have the positions shown in Fig. 14-72(a) for each waveform in Fig. 14-72(b).
Figure 14.72 Demonstrating the effect of a negative sign on the polar form.
Note in Fig. 14-72(b) that v2 passes through the horizontal axis at t = 0 s, requiring that the radius vector in Fig. 14-72(a) is equal to the peak value of the sinusoid as required by the radius vector. The other sinusoid has passed through 90° of its rotation by the time t = 0 s is reached and therefore has its maximum vertical projection as shown in Fig. 14-72(a). Since the vertical projection is a maximum, the peak value of the sinusoid that it generates is also attained at t = 0 s as shown in Fig. 14-72(b).
ET 242 Circuit Analysis II – Phasors Boylestad 16
![Page 18: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/18.jpg)
It can be shown [see Fig. 14-72(a)] using the vector algebra described that
In other words, if we convert v1 and v2 to the phasor form using
And add then using complex number algebra, we can find the phasor form for vT with very little difficulty. It can then be converted to the time-domain and plotted on the same set of axes, as shown in Fig. 14-72(b). Fig. 14-72(a), showing the magnitudes and relative positions of the various phasors, is called a phasor diagram.
ooo VVV 43.63236.290201
mm VtVv )sin(
In the future, therefore, if the addition of two sinusoids is required, you should first convert them to phasor domain and find the sum using complex algebra. You can then convert the result to the time domain.
The case of two sinusoidal functions having phase angles different from 0° and 90° appears in Fig. 14-73. Note again that the vertical height of the functions in Fig. 14-73(b) at t = 0 s is determined by the rotational positions of the radius vectors in Fig. 14-73(a).
ET 242 Circuit Analysis II – Phasors Boylestad 17
![Page 19: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/19.jpg)
In general, for all of the analysis to follow, the phasor form of a sinusoidal voltage or current will be
where V and I are rms value and θ is the phase angle. It should be pointed out that in phasor notation, the sine wave is always the reference, and the frequency is not represented.
Phasor algebra for sinusoidal quantities is applicable only for waveforms having the same frequency.
IandV IV
Figure 14.73 Adding two sinusoidal currents with phase angles other than 90°.ET 242 Circuit Analysis II – Phasors Boylestad 18
![Page 20: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/20.jpg)
Ex. 14-27 Convert the following from the time to the phasor domain:
Time Domain Phasor Domain
a. √2(50)sinωt 50∟0°
b. 69.9sin(ωt + 72°) (0.707)(69.6)∟72° = 49.21∟90°
c. 45sinωt (0.707)(45)∟90° = 31.82∟90°
Ex. 14-28 Write the sinusoidal expression for the following phasors if the frequency is 60 Hz:
Time Domain Phasor Domain
a. I = 10∟30° i = √2 (10)sin(2π60t + 30°)
and i = 14.14 sin(377t + 30°)
b. V = 115∟–70° v = √2 (115)sin(377t – 30°)
and v = 162.6 sin(377t – 30°)
ET 242 Circuit Analysis II – Phasors Boylestad 19
![Page 21: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/21.jpg)
Ex. 14-29 Find the input voltage of the circuit in Fig. 14-75 if va = 50 sin(377t + 30°)vb = 30 sin(377t + 60°)
Figure 14.75
f = 60 Hz
VjVVV
VjVVV
yieldsadditionforformrrectangulatopolarfromConverting
VVtv
VVtv
yieldsdomainphasorthetotimethefromConverting
vve
havewelawvoltagesKirchhoffApplying
b
a
bo
b
ao
a
bam
37.1861.103021.21
68.1761.303035.35
6021.21)60377sin(50
3035.35)30377sin(50
,'
ET 242 Circuit Analysis II – Phasors Boylestad 20
![Page 22: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/22.jpg)
)41.1777t77.43sin(3eand
)41.17(377t(54.76)sin2e41.17V54.76E
obtainwedomain,timethetophasorthefromConverting
41.17V54.76Vj36.05V41.22E
haveweform,polartorrectangulafromConverting
Vj36.05V41.22
j18.37)V(10.61j17.68)V(30.61VVE
Then
m
mm
m
bam
A plot of the three waveforms is shown in Fig. 14-76. Note that at each instant of time, the sum of the two waveform does in fact add up to em. At t = 0 (ωt = 0), em is the sum of the two positive values, while at a value of ωt, almost midway between π/2 and π, the sum of the positive value of va and the negative value of vb results in em = 0.
Figure 14.76
ET 242 Circuit Analysis II – Phasors Boylestad 21
![Page 23: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/23.jpg)
Ex. 14-30 Determine the current i2 for the network in Fig. 14-77.
056.56056.56
47.7342.426084.84
056.56sin1080
6084.84)60sin(10120
,'
1
31
3
1221
jmAmAI
VjmAmAI
yieldsgsubtractinforformrrectangulatopolarfromConverting
mAti
mAti
yieldsdomainphasorthetotimethefromConverting
iiioriii
havewelawcurrentsKirchhoffApplying
T
oT
TT
Figure 14.77
ET 242 Circuit Analysis II – Phasors Boylestad 22
![Page 24: Phasors ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.](https://reader035.fdocuments.in/reader035/viewer/2022062516/56649d3e5503460f94a17676/html5/thumbnails/24.jpg)
)89.100sin(108.105
)89.100sin()1082.74(289.10082.74
,
89.10082.74
,
47.7314.14
)056.56()47.7342.42(
32
322
2
12
tiand
timAI
havewedomaintimethetophasorthefromConverting
mAI
haveweformpolartorrectangulafromConverting
mAjmA
jmAmAjmAIIIThen T
A plot of the three waveforms appears in Fig. 14-78. The waveforms clearly indicate that iT = i1 + i2.
Figure 14.78
ET 242 Circuit Analysis II – Phasors Boylestad 23