P.H. (Internal )admin.osicltd.in/Siteupdate/TenderFile/4005_EOI.pdf · over foundation concrete...

23

Transcript of P.H. (Internal )admin.osicltd.in/Siteupdate/TenderFile/4005_EOI.pdf · over foundation concrete...

  • P.H. (Internal )P.H & SANITARY WORKItem of Work

    1 Supplying all materials , labours , taxes and tools and plantsfor fitting and fixing of CPVC pipes conforming to ISOSpecification with good quality including fittings and layingas per the site requirement etc., all complete includingtesting as per the direction and specification of Engineer-in-charge.

    a) 15mm diab) 20mm diac) 25mm dia2 Supplying all material, labour , T&P & fitting ,fixing the

    following different water supply fittings of brand TATA &JINDAL approved make with including supply of allnecessary jointing materials etc. all complete as directed bythe Engineer-in-charge.G.I ball valve.

    a) 25mm dia Ball Valve3 Supplying all materials , labour , tools and plants and

    constructing valve chamber of inside size 300mm x450mm x 450mm with cement concrete slab (1:1.5:3) mix of75mm thick and brick work 125mm thick in cement mortar(1:4) using K.B Bricks having crushing strength 75 kg/cm2over foundation concrete (1:5:10) and inside plastering incement mortar (1:3) finished with a floating coat of neatcement slurry including curing complete as per approveddrawing and specification and as per instruction of Engineer-in-charge.

    4 Supplying all labour T&P and cutting holes in brickmasonry wall in for taking pipes through and mending goodthe damages with supply of all required materials etc.complete as per the direction of the Engineer-in-charge.

    a) For 15mm to 50mm G.I pipe to pass in 125mm to 250mmthick wall

    5 Supplying all labour T&P and materials and makinggrooves in brick walls vertically and horizontally to therequired depth and width for fixing pipes & fittings of sizes15mm dia to 25mm dia in the grooves, testing the pipeline against leakage,and filling the grooves with cementmortar(1:4) to bring the surface to original level includingcost of mortars, curing and conveyance of materials etc.complete as per direction of the Engineer-in-charge

    RENOVATION AND RESTORATION OF OSIC BUILDING, CUTTACK

    Sl- No

    Page 1

  • 6 Supplying all materials , labour T&P and fittings required forfixing of NP or CP Brass or GM fixtures of following sizesand specification with leak proof threaded joints tightenedwith spun yarn and white zinc or any other method asrequired as directed including testing and rectification ofdetects, after testing complete as per direction of Engineer-in-chargeMake-Jaquar & ParryWare.

    a) Bibcock b) Pillar cock c) Angular stop cock d) CP Grating (125mm)e) Connecting Pipef) Soap Dishg) Towel Ringh) Basin with pedestal

    i) Providing and fixing vitreous China water closet (Europeanwith seat and lid), of Cerra, parryware, hindware Cascade“CASINO”, CP brass hinges & rubber buffers, 10 litrecascade dual flushing cistern with fittings and brackets, 40mm flush bend of CP brass, 20 mm overflow pipe withspecials & mosquito proof coupling complete, painting onbrackets and making good the walls and floors whereverrequired.

    j) Providing and fixing Urinals of P.V.C. flushing cistern withmanually controlled device (handle lever) of with all fittingsand fixtures complete including cutting and making good thewalls and floors wherever required as per direction ofEngineer-in-charge.

    k) Providing and fixing Urinals partitions of parryware/Hindwarenew division plates of star white cat no:-61005 with allfittings and fixtures complete including cutting and makinggood the walls and floors wherever required as per directionof Engineer-in-charge.

    7 Supply of all materials, labour, T&P , fitting and fixing in allfloors fixed type bevelled plate glass mirror of size 600mm x 450mm x 5.5mm thick best Indian make ,supplyof 13mm thick asbestos backing and CP Brass screwincluding cost conveyance, taxes of all materials completeas per specification and direction of Engineer-in-charge(Make-Modi Guard/Belgium)INTERNAL SEWERAGE DISPOSSAL & SANITARY INSTALLATION

    Page 2

  • 8 Supply of all materials, joining materials , labour and T&Pand laying PVC SWR PIPES of Standard make with ISIMark duly approved by the Engineer-in-charge includingjointing, earthwork in excvation of trenches in all kind of soilto the required depth and refilling of pipe line trenches in0.3048 mtrs layers with 300 mm deep sand around cushionduly watered and rammed or fixing to walls, floors withsupply of necessary clamps, nails and cutting the pipe tolength with wastage including supply of all Clamps, Clips,Endcaps & jointing materials etc, complete as per standardspecification and direction of Engineer-in-charge.

    a) 75mm dia ( ISI Marked )b) 100mm dia ( ISI Marked )c) 150mm dia ( ISI Marked)9 Supplying all materials, labour T&P for jointing of the PVC

    SWR SEWER pipe fittings of standard make dulyapproved by the Engineer-in-charge with joining materialetc. suitably required for fixing on 100mm dia soil waste pipe complete with requissite testing as directed by Engineer-in-charge.

    a) 110mm dia "P/S" Trapb) 110mm dia Bend Plainc) 110mm Door Bendd) 110mm dia. Floor trap10 Fixing of PVC vent pipes Including labour & T&P all

    complete as directed by the Engineer-in-charge.a) 100mm Pipeb) 100mm Vent Cowl11 Supplying all materials, labour, T&P for construction of

    350mm x 350mm size Gulley trap chamber by K.B.Bricksmasonry having crushing strength 75 to 99 Kg/sqcm with250mm x 250mm CI grating including labour & material forfitting and fixing 100mm X 100mm sqare mouth SW gulleytrap with supply of all jointing materials and encasing thegully trap with a block of C.C. 1:4:8 with 40mm size hardstone metal all complete with providing & fixing of 450mmX 450mm precast RCC cover with frame as per approveddesign and specification and as per the instruction of theEngineer-in-charge including cost, conveyance taxes of allmaterials to site complete as directed by Engineer-in-charge.

    Page 3

  • 12 Supplying all materials labour T&P and constructinginspection chamber C.C.(1:4:8) on bed with hard stonemetal size 40mm and 250mm K.B.Bricks work havingcrushing strength 75 Kg to 99 Kg/cm2 in cement mortar(1:4), R.C.C. roof slab with 500mm dia light pattern factorymade SFRC M.H cover with frame, moulding and shapingthe channel and benching with C.C. 1:2:4 with hard granitechips 12mm size, 12mm thick C.P 1:3 including cementpunning inside, Cement plaster 1:3 outside the chamber,earth work in excavation in all kinds of soil and refilling thecavity around the chamber as per detail drawing & designand specification including cost, conveyance, taxes etc.allcomplete as directed by Engineer-in-charge.

    a) 750mmx 750mm x450mm

    Page 4

  • A INTERNAL ELECTRIFICATIONA1 INTERNAL POINT WIRING.

    1

    Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels / V Guard )

    c Group C

    2

    Recessed wiring to secondary light point looped from primary light point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including 3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge. (Make of wire: finolex/ Anchor/Havels/L&T/KDK) Average Length: 3 mtr

    3

    Recessed wiring to ceiling fan point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC conduit with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. (Make of wire: finolex/ Anchor/ Havels/L&T/KDK) Group B

    4

    Recessed wiring to Twin control light point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type 2way switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels / V Guard )Group C

    ELECTRICAL

    RENOVATION AND RESTORATION OF OSIC BUILDING, CUTTACK

  • 5

    Recessed wiring for 5 / 6 amp socket outlet with 6Amp, 250 V clip in type modular switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection on same switch board as per direction of Engineer in Charge.

    6

    Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVC conduit with 6Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size , with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels / V Guard )Group C

    7

    Recessed wiring for 2 x 6 amp socket outlet controlled by 2 nos 6Amp, 250 V clip in type switch ISI marked mounted on single G.I moular box with face plate & cover of suitable size including all accesories and connection on separate board as per direction of Engineer in Charge.

    8

    Recessed wiring for 6 pin 16 amp socket outlet with 16Amp, 250 V clip in type switch ISI marked mounted on G.I moular box with face plate & cover of suitable size including all accesories and connection as per direction of Engineer in Charge.

    9Point wiring for Projector socket outlet with 16A plug socket and 16A control switch at nearest separate location .

    10

    Recessed wiring for A.C socket outlet with industrial type socket outlet, plug top and metal chained cover in sheet steel enclosure ,20A/32A SP MCB including all accesories and connection as per direction of Engineer in Charge.

    SUBTOTAL

    A2 SUBMAIN & CIRCUIT WIRING.

    11

    Recessed wiring to submain in 4 x 16 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 50 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 10 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. ( For A.C DB)

  • 12

    Recessed wiring to submain in 4 x 10 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 40 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. ( For PDB)

    13

    Recessed wiring to submain in 4 x 10 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 40 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 10 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. ( For CDB)

    14

    Recessed wiring to submain in 4 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. ( For LDB )

    15

    Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 4 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For ELDB & 2TR. AC POINTS )

    16

    Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For PROJECTOR SOCKET POINTS )

    17

    Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For UPS SOCKET POINTS )

    18

    Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (From DB to Switch Board & 15A SOCKET POINTS )

  • 19

    Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (From ELDB to Switch Board & MCB controlled Light Points )

    SUBTOTAL

    A3 DISTRIBUTION BOARD .Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V /240V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required wih necessary MCB , RCCB / ISOLATORS as required.

    20

    Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted 4 way TPN Distribution Boards suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.Incommer 1 No-40A FP RCCB (100mA) Outgoings-6-10 A SP MCB- 12 Nos,(L&T/ Schneider) . PDB

    21

    Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted 6 way TPN Distribution Boards suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.Incommer 1 No-40A FP RCCB (100mA) Outgoings-6-10 A SP MCB- 18 Nos,(L&T/ Schneider) . LDB

    22

    Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted 8 way TPN Distribution Boards suitable for 440 V, three phase, 4 wire 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.Incommer 1 No-63A FP RCCB (300mA) Outgoings-6-32 A SP MCB- 24 Nos,(L&T/ Schneider) . A.C DB

  • 23

    Supply, fixing, erecting, connecting and commissioning of indoor type dust and vermin proof, sheet steel clad ready made, double door horizontal type powder coated wall mounted 8 way SPN Distribution Boards suitable for 240 V, Single phase, 2 wire 50 Hz AC Supply complete with bottom detachable plate for interconnections etc as below.Incommer 1 No-32A DP MCB (10KA) Outgoings-6-32 A SP MCB- 6 Nos,(L&T/ Schneider) . ELDB

    SUBTOTAL

    A4 CABLE .

    24

    Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 3.5 C 70 sq.mm Al. direct in ground including excavation , sand cushioning protective covering and refilling the trench etc.or on surface as required.

    SUBTOTAL

    A5 END TERMINATIONSupplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.

    25 3.5C x 70 sq.mmSUBTOTAL

    A6 PANEL

    Supply, installation,testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 25KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used with Indication lamp, C.T , Digital Voltmeter, Digital Ammeter and control fuse etc. complete.

    26

    FLOOR PANEL with 100A 4P MCCB -1 No as incomer ,63A 4P MCB-2 Nos, 40A 4P MCB -4 Nos as Outgoing with E.C busbars and 1 set of 65KA 4pole VSD and 32A 4pole MCB in the incomer . SUBTOTAL

    A7 EARTHING

  • 27

    Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc with charcoal and salt as required.

    28Supplying and laying 25 mm x 6 mm CU earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required.

    29Supplying and laying 25 mm x 6 mm CU earth strip ISI marked on surface or in recess for connection etc as required.SUBTOTAL

    A8 FIXTURESupply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required.

    30

    Supply ,installation , testing & commissioning of Recess mounted indoor type Square LED Luminaire with LED Lamp Similar to CG/WIPRO/PHILIPS Cat No. RC 380B G2 LED 35S - 6500 PSD OD WH or equivalent.

    31Ceiling /Wall mounted indoor type ASTRA LED Luminaire with LED Lamp Similar to PHILIPS Cat No. BN150W LED 13S-6500 PSE ODGR or equivalent.

    32Recess mounted indoor type ROUND LED Luminaire with LED Lamp Similar to PHILIPS Cat No. BBS170 1xDLED 5000 PSU WH or equivalent.

    33

    Supply ,installation , testing & commissioning of surface mounted indoor type Mirror LED Luminaire with LED Lamp Similar to PHILIPS /WIPRO/ CG Cat No. LCL-07-CDL or quivalent.

    34 9W LED Lamp Equiv. to PHILIPS Cat No. ESSENTIAL LED 2.6-20W MR16 6500K 24D.

    35Recess mounted indoor type MINI ROUND LED Luminaire with 3watt LED Lamp Similar to Crompton Cat No. LSDMAGICRM-3W or equivalent.

    36 Strip LED Luminaire with LED Lamp Similar to Crompton Cat No. LST20CD/BL/WW or equivalent.

    37

    Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required.

    38

    Supply, Installation, testing and commissioning of exhaust fan of 300 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required.

  • 39

    Supply, Installation, testing and commissioning of high speed wall fan of 400 mm sweep 900 rpm on partition wall/ brick wall , making good the damage complete, connection, etc as required.

    40 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required

    41

    Providing and fixing extra down rod of 50 cm length G.I. pipe 20 mm dia heavy gauge including painting etc as required . ( more than 5 cm lenght shall be rounded to the nearest 10 cm and 5 cm or less shall be ignoredSUBTOTAL TOTAL

    B CCTV, DATA & COMMUNICATION

    42

    Recessed wiring to television point with cable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid and protected with FR PVC sheath in 20 mm dia non-metalic PVC conduit with clip in type modular television socket ISI marked mounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.

    43

    Recessed wiring to telephone point with clip in type modular telephone socket (RJ 11) ISI marked mounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.

    44

    Recessed wiring to LAN point with clip in type modular lan socket (RJ45) ISI marked mounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.

    45

    Supplying and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 60 mm deep on surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required.

    46

    Supplying and fixing of 25mm PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.

    47Supplying and drawing one pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessed PVC conduit as required.

    48 Supplying and drawing UTP 4 pair LAN cat-6 cable in the existing surface / recessed PVC conduit as required.

    49

    Supply,delivery, installation,testing & commissioning of indoor wall mounted type telephone distribution box having following number of junctions made out of 1.6mm thick CR sheet steel duly primered & painted with enamel paint having hinged front door, testing facility having provision for cable / conduit entry complete as per direction of Engineer-in-charge.

  • MDF box suitable for 50 pair telephone cable termination.

    50Supply of push button hand sets of make TATA / Betel / BPL / SIEMENS.or equivalent Samples shall be got approved.

    51Supply, delivery, installation,testing & commissioning of Advanced Digital EPABX Systems with 43 Extension & all accessories complete as required.

    52

    Supply, delivery, laying and testing of following sizes of PVC insulated jelly filled armoured telephone cable laid on surface of wall/ column/ roof/ partitions of the building or inside prelaid conduit/ hume pipes/ GI pipes/ soil digging, as the case may be, complete as required and as per direction of Engineer-in-charge.50 Pair TOTAL

    C UNDER FLOOR RACEWAYSupply & installation of G.I under floor race ways & accessories made out from pre galvanised 1.6mm thick CRCA sheet steel & openable cover in recess/ in floors including all accessories such as metal fasteners, couplers, hardware, clamps/brackets, bends etc. as required. The work includes cutting of floors/walls & making same as good etc. as required.

    53 300x38mm with 3 compartments54 225x38mm with 3 compartments

    Supply & installation of metal Floor Junction/Tee Boxes with cover suitable for under floor race way made out from pre galvanised 1.6mm thick CRCA sheet steel & openable cover in recess/ in floors including all accessories such as metal fasteners, couplers, hardware, etc. as required. The work includes cutting of floors/walls & making same as good etc.

    55 300X300X65mm -90mm56 225X225X65mm -90mm

    CABLE TRAYSupplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

    57 150 mm width X 50 mm depth X 1.6 mm thickness

    TOTAL

    FIRE ALARM AND PUBLIC ADDRESS SYSTEM

  • 58

    Supply, installation, testing & commissioning of VDS/UL listed Intelligent Mutli Criteria Detector with inbuilt Short Circuit Isolator with standard detector base etc. to install under/above false ceiling, roof and concealed space etc.complete as required as per specification. with provision of time based programming & soft addressing

    59

    Supply, installation, testing & commissioning of Addressable loop powered Flasher (Specification:-Addressable flashing light for optical signalling of a fire alarm in indoor areas, suitable for direct connection to the loop. The flashlight shall be in red colour, with the flash rate being set by means of software and using DIP switches. The flashlight shall have the integrated Short Circuit Isolator.Approval: VdS / UL 9th edition)

    60

    Supply, installation, testing and commissioning of integral microprocessor (not microcontroller) intelligent soft addressable type heat detector (combined rate of rise and fixed temperature) consists of two independent thermistors, designed to automatically compensate changes in ambient temperature with moisture free, rust free & gold plated terminals in base complete as per specifications as required.

    61

    Supply, installation, testing & commissioning of Addressible Manual Call Point with Rugged die cast housing and corrosion resistant construction conforming to EN 54-11 (Type A) . Approval: VdS / UL 9th edition.

    62Supply, installation, testing and commissioning of UL/EN listed wall mounted hooter with strobe (100 dba) complete as per specification as required.

    63 Supply, installation, testing & commissioning of Isolator Module.

    64

    Supply and laying of 2 core, 2.5 sq. mm. Fire Survival cable, armoured copper conductor of 600/1000V grade, insulated with specially formulated PVC, coated with special fire resistance materials and overall sheathed with special PVC, with special properties as Zero Halogen Low Smoke insulation. Basic construction as per BS 7846-2009 & circuit integrity as per BS 6387 C W Z /BS EN 50200.

    65

    Supplying and fixing of 16 / 18 SWG metal box of 100 mm x 150 mm x 60 mm deep on surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required.

    66

    Supply, installation, testing and commissioning of UL/EN listed surface type mounted directly on ceiling/ recessed 1/4-1/2 tap changer 6 watt speakers with line matching transformer complete as per specification as required.

    67Supplying, fixing, testing and commissioning of UL/EN listed fixed telephone talk back units (fire fighter telephone hand set) compatible to MFACP complete as required.

  • 68 Supplying, fixing, testing and commissioning of 240 watt Mixer Amplifier with accessories complete as required.

    69

    Supplying and fixing of 20mm dia PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required

    70

    Supplying, wiring, testing and commissioning of point wiring for speakers with 2 core 1.5 Sq.mm cu. Twisted copper conductor wire including loop wiring in existing rigid PVC conduit as required. TOTAL

    D SAFETY EQUIPMENTS

    71Supply and installation of Rubber Mats 12mm thick of size 2000mm x 1000mm x 12 mm thick Electrical tested with test certificate.

    72Supply and fixing of fire buckets with angular fabricated stand to fix 4 buckets in each stand for Electrical fire protection as per standards of Electrical Inspectorate.

    73 Supply and fixing of Co2 fire extinguisher with mounting clamps with pressure test certificate .

    74Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room.

  • R.C.C- M201 Providing, lifting, hoisting and laying Reinforced cement

    concrete of M-20 Grade having a crushing strength ofin 15cm cubes at 28 days after mixing adn tests conductedin accordance with IS 456 and IS 516 in footing, PlinthBand, Lintels, Chajja, Shelf fins, Roof slabs,Balconies,Column, Beam Parapets, Window sills, Lofts,Railings etc. with 12mm to 20mm size black hard crusherbroken granite chips of approved quality from approvedquarry including mixing and compacting to proper shapeand size, level and plumb and finishing the exposedsurfaces smooth including cost of scaffolding, wateringand curing for the required period including cost of allmaterials with taxes, royalties transportation, loading andunloading, all labour, sundries, T&P including hire &running charges of concrete mixer and vibrator etccomplete as per the direction of the Engineer-in-charge butexcluding the cost of materials and labour forreinforcement bars , centering and shuttering for the work.

    a) First floor

    Reinforcement 2 Providing & fixing TOR Fe-500 reinforcement bars for RCC

    work of required diameter of approved quality withstraightening, cutting, bending, binding welding and joining(if necessary) and tying the grills and placing in position asrequired for R.C.C. work and providing fan hooks, hoisting,lowering and laying including cost, conveyance and taxesof M.S. Rods or tor steel and binding wires of 18 to 20gauge and labour required for the work for bending,binding and tying the grills in all heights as per thespecification & direction of E-I-C. (Linear measurementswill be taken & quantity will be calculated on standardweight. Weight of binding wire will not be considered formeasurement.)a) First floor

    Centering and Shuttering

    RENOVATION AND RESTORATION OF OSIC BUILDING, CUTTACKCIVIL WORK

    Page 1

  • 3 Providing strong, rigid, leveled and plumbed centering andshuttering to required shape and size for all kinds ofR.C.C. works in the items mentioned below with woodencentering materials with all necessary bracing, ties andsupports with level centering covered with bituminouspaper including provision of necessary holes and pockets,fan hooks or boxes, switch and board insert plates, clampsand extension bars etc. as per the direction of theEngineer-in-charge and dismantling and removing theshuttering after the required interval from the date ofcasting, including cost of all materials with transportation,taxes, loading and unloading etc. and all labour, sundries,T&P scaffolding etc. complete.

    Lintel a) First floorChajjaa) First floor

    Brickwork in Super Structure4 K.B brick masonary work using (250mm x 120mm x

    80mm) size K.B bricks having crushing strength not lessthan 75 kg/cm2 in cement mortar mix (1:6) on (250mm &125mm thick) masonary walls after immersing the bricksfor 6 hrs in water before use in superstrure and similar typeof work as per drawings. including cost, conveyance, alltaxes, royalties, loading and unloading of all materials,including cost of all labour, scaffolding, watering andcuring, sundries, T&P etc. complete as per the directionof the Engineer-in-charge.

    a) First floor

    16mm thick Inside Plaster 5 Providing 16mm thick cement plaster to the inside surface

    of masonary wall with cement mortar (1:6) includingracking out joints, scraping and cleaning the surface andfinishing the plastered surface smooth using wooden floatsonly to proper plumbs and level as per drawings includingcost of all materials, conveyance, loading and unloading,all taxes and royalties, labour, scaffolding, watering andcuring, sundries and T&P etc. complete as per direction ofthe Engineer-in-charge

    a) First floor12mm thick Outside Plaster

    Page 2

  • 6 Providing 12mm thick cement plaster to the outsidesurface of masonary wall with cement mortar (1:6)including racking out joints, scraping and cleaning thesurface and finishing the plastered surface smooth usingwooden floats only to proper plumbs and level as perdrawings including cost of all materials, conveyance,loading and unloading, all taxes and royalties, labour,scaffolding, watering and curing, sundries and T&P etc.complete as per direction of the Engineer-in-charge

    a) First floor

    Plastic Emulsion Paints with pop7 Providing & Painting two coats with Plastic Emulsion

    panits of approved shade make or equivalent over a coatof primer and pop by means of roller to inside surface ofnew walls and ceilling, including preparation of base andfinishing the surface smooth including all cost ofmaterials,labour, scafolding, T & P etc. complete as pe the directionof E-I-C.a) First floor

    Wood Works-Sal wood Choukaths8 Providing, fitting and fixing in proper position seasoned and

    dressed Sal wood choukaths of size 75mmX 125mm ofbest quality in doors & windows as per approved designand drawings including cutting the grooves in choukaths asrequired, painting two coats of coal tar or hot bitumen tothe rear face in contact with masonry or concrete surfaceand fixing with 35mm x 5mm size W.I. clamps includingcost, conveyance, taxes of all materials, all labour, T&Petc. complete in all respect as per direction of Engineer-in-charge in all floors.

    First FloorFlush doors with veneer

    9 Providing fitting and fixing factory made flush doors of35mm thick finished with 4mm thick veneer and teakbeadings/ lippings including polishing the exposed surfacewith melamine finish including supplying, fitting fixingwooden hinged cleats brass aldrops, tower bolts, doorclosure, mortice locks, iron hinges screws etc. complete asper requirement and any additional fittings as directed bythe Engineer-in-charge First Floor

    PVC Door

    Page 3

  • 10 Providing and fixing 30mm thick factory made PVC rigidfoam paneled door shuttes with choukhat manufactured byM/s Rajshri or equivalent made from M.S. tube of 19gauge thickness, size 19x19mm for styles and 15x15mmfor top and bottom rails, covered with heat moulded PVC“C” channel of 5mm thick sheet and 30x50mm wide toform styles and 5mm thick and 75mm wide PVC sheets fortop rail, lock rail and bottom rail on other side and 5mmthick, 20mm wide cross PVC sheet as gap insert for toprail and bottom rail, paneling of 5mm thick PVC sheet fittedin the M.S. frame welded / sealed to the styles and railswith 5x30mm PVC sheet beading on either side and joinedtogether with solvent cement adhesive etc., complete asper manufacturers specification including fixing frameswith 4 Nos. M.S. powder coated butt hinges completeincluding one 10inch aluminium aldrop and twoaluminium tower bolts of 10inch and 6inch and twoaluminium handles cost of all materials, conveyance,loading, unloading, and taxes of all materials, cost of alllabour, sundries, T&P required for the work as per direction a) First floor

    ventilators11 Supplying, fitting and fixing glazed ventilators made out

    powder coated aluminium sections of matt black finish,with all standard fixtures and fittings with groove forinserting 5mm heat reflective Glazing of Saint Gobain OrEquivalent as per approved design, with glazing bar,nonfriction projection type hinges, lugs, steel peg stay300mm long, point nose of approved quality, fixing inposition with cement concrete (1:2:4) cutting holesmending good damages to match with the existing surfacecomplete in all respects.

    a) First floor

    Page 4

  • Flooring - Ceramic tiles12 Supplying, fitting and fixing in position 7-8mm thick

    ceramic floor tile of Kajaria/NITCO/JOHNSON ofsizes notless than 12"X12" of premium quality and size in allfloors & steps with application of 20 mm thick cementmortar of ( 1: 3) in proper slop and filling the gaps withwhite cement and colouring the surface with silicon paintfinished as per the design & drawing with all cost ofmaterials, labour,conveyance, taxes T&P and complete asper the direction of the Engineer-in-charge

    In Floor a) First floor

    Glazed tiles for the walls13 Supplying, fitting and fixing in position 6.5-6.7mm thick

    ceramic concept wall tile with borders of Kajaria/ NITCO/JOHNSON/ EURO of premium quality and size not lessthan 12"X12" in dadoes in all floors at all heights and riserof steps with application of 12 mm thick cement mortar of( 1: 3) in proper slop and filling the gaps with white cementand colouring the surface with silicon paint finished as perthe design & drawing with all cost of materials,labour,conveyance, taxes T&P and complete as per thedirection of the Engineer-in-charge

    In dado a) First floor

    Outside weather coat paint with primer14 Preparing surface and painting with weather coat paint of

    approved make, shade and quality in all heights of walls,ceiling, sun sheds fins etc. incl. providing scaffolding,cleaning, curing and supply of all materials and labourcomplete.a) First floorGranite slab

    15 Providing and fixing 19 mm thick mirror polished, machinecut black granite for kitchen counter and verandahsteps of required size of approved shade, colour andtexture laid over 20 mm thick base cement mortar 1:4 (1cement : 4 coarse sand) with joints treated with whitecement, mixed with matching pigment, epoxy touch ups,including rubbing, curing etc. complete at all levels.

    First Floor

    Page 5

  • 1 Providing and fixing Suspended Gypsumboard/Armstrong falseceiling (single layer) in different levels , recesses ,flat areas as perdesign with G.I. framework (of perimeter channels, intermediatechannels and ceiling sections) and 12.5 mm taped edgegypsumboard screw fixed to ceiling section as per design , completewith fixing and finishing of tapered and square edges of board withjointing compound paper tape and 2 coats suitable primer includingall cost of materials , labour, overheads, T & P etc., complete as perdirection of the Engineer‐in‐Charge.Ceiling to be levelled and freefrom cracks. Arrangements are to be made to accomodate lightingfixtures, and to be tied with perimeter channels with required hardwares etc .complete.

    Total2 Providing and fixing Wall panelling/Partition made out of 12 mm

    ply,1 mm thick laminate ( over partition/ wall panelling for design) complete with necessary Hardwood etc. as per the detail designincluding the cost of all materials, labour, overheads and T & P etc.complete .as per the direction of the Engineer in charge.

    Total3 providing ,fixing,fitting designer solid/ partly glazed 32mm thick

    flush door shutters confir to IS:2202 decorative type of withlaminates.

    Total4 Providing and fixing of Full Height storage cabinet to the other area

    with 19mm BWR board & 6mm th bwr ply at the back side andfinished with 1mm laminates and finished the wooden lipping &internal surface with enamel paint to match the laminate shadeand as per direction of the Engineer‐in‐Charge.

    Total5 Providing and putting in position Working Table of 19mm thick

    block board with lamination 1.0mm(natural finish )and top madewith post formed laminate with 25mm thick particleboard/MDFcover with 12mm thick glass including provision for keyboard tray of " Earl Bihari" make or equivalent with lockingarrangement, drawer made of 19mm ply with sleek telescopicdrawer slide(EB.No. 170523/87) and the flap made out of 19mmblock board with auto closing hinge equivalent to(EBNo.158991/87) with inside surface painted with approved paintwith locking arrangement with teak beading etc. asper drawing anddirection of consultant or Engineer in charge.

    a. Executive Table with credenzaTotal( size 2.4x0.9m) credenza (2.4x0.77m)x1

    INTERIOR FURNISHING WORK

    RENOVATION AND RESTORATION OF OSIC BUILDING, CUTTACK

  • Total( size 1.65x0.9m) credenza (0.9x0.77m)x7

    b. Workstation Table with credenzaTotal( size 2.7x0.77m) x 30

    6 Providing Executives Chair of Godrej/ Featherlite/Durian/equivalent make of approved design including cost,conveyance, all taxes etc complete and as per direction of theEngineer‐in‐Charge.Total

    7 Providing Guest Chair of Godrej/ Featherlite/ Durian/equivalentmake of approved design including cost, conveyance, all taxes etccomplete and as per direction of the Engineer‐in‐Charge.

    Total

    8 Providing Sofa of Godrej/ Featherlite/ Durian/equivalent make ofapproved design including cost, conveyance, all taxes etc completeand as per direction of the Engineer‐in‐Charge.

    3‐Seater1‐Seater

    9 Providing, fitting & fixing Floor Spring of Dorma /equivalent makeincluding cost of all materials,labour, Transportation, placing inposition etc. complete.as per the direction of Engineer ‐in‐charge.

    Total10 Providing, fitting & fixing Door Handle of 450mm long of Dorma/

    equivalent make including cost of all materials,labour,Transportation, placing in position etc.complete.as per the directionof Engineer‐in‐charge.

    Total11 Providing, fitting & fixing Godrej/ Doorset/ equivalent Locks for

    Doors/ equivalent make including cost of all materials, labour,transportation placing in position etc.complete.as per thedirection of Engineer‐in‐charge.

    Total12 providing, fixing, fitting door closer of Dorma/equivalent make

    including cost of all material

    Total13 providing & fixing of roller blinds in position at all levels with

    louver made of polyster base febric of approved shade

    TotalGranite slab

  • 14 Providing and fixing 19 mm thick mirror polished, machine cutblack granite for lift facia and toilet basin slab of requiredsize of approved shade, colour and texture laid over 20 mmthick base cement mortar 1:4 (1 cement : 4 coarse sand) withjoints treated with white cement, mixed with matching pigment,epoxy touch ups, including rubbing, curing etc. complete at alllevels. First Floor

    Toughen door15 providing & fixing of TOUGHEN GLASS DOOR of approved make in

    the front entrance with necessary fitting & fixture, silicon completein all respect as per the direction of Engg‐in‐charge.