Permit number Building Regulations 2012, regulation 4, 21
Transcript of Permit number Building Regulations 2012, regulation 4, 21
PERMIT FORM BA4 Building permit
Form approved by the Building Commissioner on 30 June 2016 Page 1 of 2
Building Act 2011, section 25 Building Regulations 2012, regulation 4, 21
Permit number 5878
1. Builder details
Builder’s name
Street address (provide lot number where street number is not known)
Unit no
Street no
Level
Lot no
Street name
Street type
Street suffix
Suburb
State
Postcode
Country (if not Australia)
OR
PO Box address PO Box no 1255
Suburb SUBIACO
State WA
Postcode 6008
Country (if not Australia)
Registration number or owner-builder approval number (if applicable)
2. Details of building work
Property street address (provide lot number where street number is not known)
Unit no
Street no
Level
Lot no 44
Street name GREAT NORTHERN
Street type HIGHWAY
Street suffix
Suburb NEWMAN
State
Postcode
Nature of the building work
Placement of 15 water tanks a sea container and an 1800mm high fence.
Stage(s) of work
BCA class of the building
Main BCA class 10a
Secondary BCA class (for multi-purpose buildings) 10b
Use(s) of the building Waste Water Treatment Plant Infrastructure Each restriction on use (if applicable)
Estimated value of building work (as determined by permit authority)
BA4
Form approved by the Building Commissioner on 30 June 2016 Page 2 of 2
3. Applicable certificate of design compliance
Certificate of design compliance issued by:
Building surveying contractor/public authority’s name
Victor Etherington
Phone/fax Phone no 9175 8000
Fax
Email address [email protected] Date 03/06/2021
4. Permit details
All building work permitted by this permit: 1. Must be carried out in accordance with the plans and specifications specified in the applicable certificate of
design compliance for this building permit.
2. Must be carried out in accordance with any conditions set out below:
Conditions
Treatment plant must not commence until Department of Health approval has been received to construct and install.
3. Must be inspected and tested as prescribed under section 36(2)(a) of the Building Act 2011 (refer to the certificate of design compliance for the applicable list of inspections and tests that are to be listed here):
Inspections and tests
4. A permit granted to do one or more stages of building work does not automatically entitle a person to be granted a further building permit for any other stage of the building work.
5. This permit is valid for two years from the date of this permit OR valid until Date
Issuing officer Name
Job title
Permit authority
CERTIFICATE FORM BA3
Certificate of design compliance
Form approved by the Building Commissioner on 14 April 2021 Page 1 of 4
Building Act 2011, section 19 Building Regulations 2012, regulation 4, 18A, 18B, 18C PERMIT AUTHORITY
USE ONLY Reference number 5878
BUILDING SURVEYING USE ONLY
Reference number
1. Property this certificate relates to Property street address (provide lot number where street number is not known)
Unit no
Street no
Level
Lot no 44
Street name GREAT NORTHERN
Street type HIGHWAY
Street suffix
Suburb NEWMAN
State WA
Postcode 6753
Local government area SHIRE OF EAST PILBARA
Main BCA class of the building
10a
Secondary BCA class (for multi-purpose buildings)
10b Third BCA class (for multi-purpose buildings)
Use(s) of the building
WASTE WATER TREATMENT INFRASTRUCTURE
Each restriction on use (if applicable)
Description of the building(s) and building work
Placement of 15 water tanks a sea container and a 1800mm high fence.
2. Applicable building standards
The edition of the Building Code applied in respect of this building or incidental structure
NCC SERIES 2019 VOLUME 2 AMENDMENT ONE
Any declaration under section 39 of the Building Act 2011 made in respect of this building or incidental structure
N/A
Bush fire prone areas (only required for the types of buildings or incidental structures stated below)
In respect of a Class 1, Class 2 or Class 3 building or an associated Class 10a building or deck that is located less than six (6) metres from the Class 1, Class 2 or Class 3 building:
Is the building or deck located in a bush fire prone area? Yes No (if No, continue to part 3)
Under regulation 31BA or 31D of the Building Regulations 2012, does a bush fire performance requirement apply to the building or deck?
Yes. The Bushfire Attack Level or other measure is:
No. Does not apply because of:
(if No, nominate the relevant concession(s) provided under regulation(s) 31BA or 31D)
BA3
Form approved by the Building Commissioner on 14 April 2021 Page 2 of 4
3. Plans, specifications and other documents
Plans and specifications specified in accordance with section 19(3) of the Building Act 2011
Drawing numbers
Architectural Drawings stamped “certificate of design compliance 5878” PAGES 1 to 12
Specifications
N/A
Technical documents
N/A
4. Other prescribed requirements
Details of any advice given by the FES Commissioner in respect of the plans and specifications (Class 2 to Class 9 buildings only)
N/A
Details of any notification given to the FES Commissioner under regulation 15A(1) of the Building Regulations 2012 (Class 2 to Class 9 buildings only)
N/A
Details of each performance solution and the assessment methods used as required under regulation 18A of the Building Regulations 2012 for:
• Class 2 to Class 9 buildings; or
• the bush fire performance requirement for Class 1 buildings in bush fire prone areas.
N/A
5. Inspections and tests
List the applicable inspections and tests prescribed under section 36(2)(a) of the Building Act 2011 (i.e. as prescribed in regulations 27 and 28 and Schedule 3 of the Building Regulations 2012)
BA3
Form approved by the Building Commissioner on 14 April 2021 Page 3 of 4
6. Declaration
1. This building or incidental structure, if completed in accordance with the plans, specifications and technical documents specified in part 3 of this certificate, will comply with each applicable building standard.
2. I have applied the edition of the Building Code specified in part 2 of this certificate in respect of the building or incidental structure.
3. A declaration under section 39 of the Building Act 2011 that a building standard does not apply or is modified in a way as specified in part 2 of this certificate in respect to this building or incidental structure has been made or has not been made.
4. Each performance solution that is relied upon to establish compliance with a building standard is shown on the plans and specifications specified in part 3 of this certificate. Where required, I have made the necessary statements in part 4 of this certificate.
5. Where required by the Building Regulations 2012, plans and specifications provided in sufficient detail to allow assessment of compliance with the FES Commissioner’s operational requirements were provided to the FES Commissioner at least 15 business days prior to the date of this certificate.
6. Details of any advice given by the FES Commissioner in respect of the plans and specifications are set out in part 4 of this certificate.
7. I have notified the FES Commissioner of the details of any part of the FES Commissioner’s advice that is not incorporated in the plans and specifications specified in part 3 of this certificate and the reasons for not incorporating that advice and details of this notification are set out in part 4 of this certificate.
8. Where this certificate relates to a Class 1, Class 2 or Class 3 building or an associated Class 10a building or deck that is located less than six (6) metres from the Class 1, Class 2 or Class 3 building, I have made the required statements in part 2 of this certificate in respect to bush fire prone areas.
9. I am an independent building surveyor as defined in section 4 of the Building Act 2011.
Building surveying practitioner’s name VICTOR ETHERINTON
Street address (provide lot number where street number is not known)
Unit no
Street no
Level
Lot no
Street name
Street type
Street suffix
Suburb
State
Postcode
Country (if not Australia)
OR
PO Box address PO Box no 22
Suburb NEWMAN
State WA
Postcode 6753
Country (if not Australia)
Email address [email protected]
Phone/fax Phone no 08 9175 8000
Fax
Registration details
Building surveying practitioner’s signature
BA3
Form approved by the Building Commissioner on 14 April 2021 Page 4 of 4
7. Certificate issued by Building surveying contractor / public authority’s name
SHIRE OF EAST PILBARA
Street address (provide lot number where street number is not known)
Unit no
Street no
Level
Lot no
Street name
Street type
Street suffix
Suburb
State
Postcode
Country (if not Australia)
OR
PO Box address PO Box no PMB 22
Suburb NEWMAN
State WA
Postcode 6753
Country (if not Australia)
Email address [email protected]
Phone/fax Phone no 08 9175 8000
Fax
Registration details (contractors only)
Registration number
Level
Building surveying contractor/public authority officer’s signature
24 STANDARD CARBAYS AND 2 DISABLED BAYS72 EXISTING SINGLE STOREY ROOMS
6 EXISTING DISABLED ROOMS
ADMIN OFFICE
36 EXISTING DOUBLE STOREY ROOM
OPEN DRAIN
LAUNDRY
40 EXISTING SINGLE STOREY ROOMS
LINEN STORE
LAUNDRYRETROSPECTIVE D.A:MANAGER'S & STAFF RESIDENCES
RETROSPECTIVE D.A: GYM &REC ROOM
MAINTENANCE SHED
EXISTING GENERATOR SHED
55 BUILDINGS +4 LAUNDRIES
OPEN SPACEREC. AREA
NEW DEVELOPMENT AREA: EXTENDED DINING ROOM (II)
WWTPNEW DEVELOPMENT AREA:CAR PARK 36 BAYS
FUTURE SINGLE STOREY ACCOM.72 BUILDINGS (278 ROOMS)INCLUDING 6X DISABLED PLUS 2 XLAUNDRIES
54 PARKING BAYS. UNSEALED
NEW DEVELOPMENT AREA:79 PARKING UNSEALED BAYS
NEW DEVELOPMENT AREA: EXTENDED KITCHEN
STAGE 1: NEW DEVELOPMENT AREA
BUS waiting
NEW DEVELOPMENT AREA: 5PARKING BAYS UNSEALEDROAD TRAINS
LIGHT INDUSTRYRESTRICTED TO
PATRON SERVICE
EMERGENCYROAD OUT
NATURALAMPHITHEATRE
NEW DEVELOPMENT AREA:1 BUS BAY
NEW DEVELOPMENT AREA:CAR PARK 20 BAYS
EXISTING TREES TO BERETAINED
X
MUSTER POINT
NEW DEVELOPMENT AREA:BUS TURNAROUND
NEW DEVELOPMENTAREA:258 PARKING BAYS.UNSEALED
X
MUSTER POINT
LAUNDRY
DISABLEDROOMS NEW DEVELOPMENT AREA:
9000mm SETBACK TOBOUNDARIES AND GREENSCREEN VEGETATION BUFFERFOR HOME
D.A ADDITION: DOUBLE CAR PORT
NEW DEVELOPMENT AREA:1 BUS BAY
RETROSPECTIVE D.A: CARPORT
PROPOSED BAR
RETROSPECTIVE D.A: DINING ROOM (I)
DA ADDITION: WATER TANK
RETROSPECTIVE D.A: 5BUILDINGS
CARPORT
D.A ADDITION: PORTICO
D.A ADDITION: SHADE STRUCTURE
8200
61000
1. CHECK DIMENSIONS PRIOR TO CONSTRUCTION2. DO NOT SCALE FROM DRAWINGS3. DRAWINGS ARE TO BE READ IN CONJUNCTIONWITH STRUCTURAL ENGINEERS DRAWINGS4. BUILDER TO CONFIRM SITE SETOUT, LEVELS &BOUNDARIES PRIOR TO CONSTRUCTION5. BUILDER TO ADVICE OF DEVIATIONS FROM THEDRAWINGS PRIOR TO CONSTRUCTION6. ADVICE ANY DISCREPANCIES FORRESOLUTION PRIOR TO CONSTRUCTION7. ALL CONSTRUCTION ARE TO BE CARRIED OUTIN ACCORDANCE WITH THE CURRENTAUSTRALIAN STANDARDS & BUILDING CODE OFAUSTRALIA
1 ISSUED FOR D.A 21-12-20
P: 0420763885E: [email protected]
M A T T H I E S S E NA R C H I T E C T S
OASIS AT NEWMAN
SCALE 1:2500 @ A3
0 10m 30m 60m 100m
MASTER PLAN
1. BUILDER TO CHECK SITE AND BOUNDARYSURVEY AND CURRENT PEG OUT OF SITE.REPORT DISCREPANCIES TO CLIENT2. BUILDER TO CHECK LOCATION OF EXISTINGTREES. REPORT DISCREPANCIES ANDCLASHES TO CLIENT
2 ISSUED FOR D.A 23-12-203 ISSUED FORINFORMATION 07-01-214 ISSUED FOR D.A 14-01-215 ISSUED FOR D.A ADDITION 10-02-216 ISSUED FOR D.A 16-03-21
GRID IS 10m x 10m
7 ISSUED FOR B.A 08-04-218 ISSUED FOR B.A 28-04-21
Certificate of Design Compliance 5878
BUILDING PERMIT 5878
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8
3 OF 73 OF 7
1:500 1:500
AQUASOLWater Treatment Solutions82-86 BERINGARRA AVE
MALAGA WA 6090
T: +61 8 9248 7533
ACN: 157 831 411
DATE:22.04.21 250 M3/HR WASTEWATER RECYCLING PLANT
SATELITE VIEW – PROPOSED WWTP AREA
AQ-OAS-004-03
LYU
LYU
NEWMAN
OASIS
DESIGN:
DRAWN:
PROJECT:
CLIENT:
DRAWING TITLE:
DOCUMENT NO:
© Copyright AQUASOL February 2021. This document is and shall remain the proper ty of Aquasol and may only be used for the
purposes or demonstration in accordance with terms outl ined in this document or attached documents. Unauthor ised use of this
document or design in any form whatsoever is prohibited, and Aquasol reserves the right to take legal action.
1REVISION:
A3SHEET SIZE: SCALE:
PAGE:
TYPE:ORTH / ISOM / P&ID
BAL
BAL
BAL
CL
BO
BOFW
BOFW
FWFW OUT
BORE WATER FEED
BALANCE TANK FEED
Certificate of Design Compliance 5878
BUILDING PERMIT 5878
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8
4 OF 74 OF 7
1:200 1:200
AQUASOLWater Treatment Solutions82-86 BERINGARRA AVE
MALAGA WA 6090
T: +61 8 9248 7533
ACN: 157 831 411
DATE:27.04.21 250 M3/HR WASTEWATER RECYCLING PLANT
SITE GENERAL LAYOUT
AQ-OAS-004-04
LYU
LYU
NEWMAN
OASIS
DESIGN:
DRAWN:
PROJECT:
CLIENT:
DRAWING TITLE:
DOCUMENT NO:
© Copyright AQUASOL February 2021. This document is and shall remain the proper ty of Aquasol and may only be used for the
purposes or demonstration in accordance with terms outl ined in this document or attached documents. Unauthor ised use of this
document or des ign in any form whatsoever is prohibited, and Aquasol reserves the right to take legal action.
3REVISION:
A3SHEET SIZE: SCALE:
PAGE:
TYPE:ORTH / ISOM / P&ID
BALANCE
BALANCE
BALANCE
CHLORINE
IRRIGATIONBORE
WATER
BORE
WATERFRESH
WATER
BORE
WATERFRESH
WATER
FRESH
WATER
SBR 1
SBR 2SBR 3
SBR 4
SLUDGE
TANK
POLISH TANK
1
POLISH TANK
2
AEROBIC
TANK
PHASE 1 INSTALLATION
QTOTAL = 70 m3.day-1
SBR 5
Ø4570
PHASE 2 INSTALLATION
QTOTAL = 250 m3.day-1
ALL TANKS ~ 4600 Ø
BORE
WATER
BORE
WATER
BORE
WATER
FRESH
WATER
FRESH
WATER
FRESH
WATER
SW – VEHICLE ACCESS GATE
2 X 2000
NE – VEHICLE ACCESS GATE
2 X 2000
PERSONNEL ACCESS GATE
1 X 900 *
PERIMETER FENCE
LEGEND
PHASE 1 INSTALLATION
NEW TANKS 50 m3, 4600Ø
- POLISH TANK 1 (50 M3)
- SEQUENTIAL BATCH REACTOR (SBR) 1, 2 (50 M3)
- AEROBIC TANK (50 M3)
PHASE 2 INSTALLATION
NEW TANKS 50 m3, 4600Ø
- POLISH TANK 2 (50 M3)
- SEQUENTIAL BATCH REACTOR (SBR) 3, 4, 5 (50 M3)
NEW WASTEWATER
RECYCLING PLANT AREA
PROPOSED FUTURE INSTALLATION
LOCATIONS
- BORE WATER TANK
- FRESH WATER TANK
OASIS BOUNDARY
Certificate of Design Compliance 5878
BUILDING PERMIT 5878
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8
1:50 1:50
AQUASOLWater Treatment Solutions82-86 BERINGARRA AVE
MALAGA WA 6090
T: +61 8 9248 7533
ACN: 157 831 411
DATE:27.04.21 250 M3/HR WASTEWATER RECYCLING PLANT
40' SEA CONTAINER ELEVATION PLAN
AQ-OAS-004-05
LYU
LYU
NEWMAN
OASIS
DESIGN:
DRAWN:
PROJECT:
CLIENT:
DRAWING TITLE:
DOCUMENT NO:
© Copyright AQUASOL February 2021. This document is and shall remain the proper ty of Aquasol and may only be used for the
purposes or demonstration in accordance with terms outl ined in this document or attached documents. Unauthor ised use of this
document or design in any form whatsoever is prohibited, and Aquasol reserves the right to take legal action.
3REVISION:
A3SHEET SIZE: SCALE:
PAGE:
TYPE:ORTH / ISOM / P&ID
WASTEWATER RECYCLING PLANT
FILTRATION SEA CONTAINER
POLISH TANK 2SBR 3FROM NORTH WEST
FROM SOUTHWEST
POLISH TANK 2 POLISH TANK 1
WASTEWATER RECYCLING PLANT
FILTRATION SEA CONTAINER1
800
302
5
2440
4600
302
5
121921175 1175
180
0
4600
46004600 1650
40' SC DOOR 40' SC DOOR
5 OF 75 OF 7
Certificate of Design Compliance 5878
BUILDING PERMIT 5878
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8
1:240
AQUASOLWater Treatment Solutions82-86 BERINGARRA AVEMALAGA WA 6090T: +61 8 9248 7533ACN: 157 831 411
DATE:01.06.21 OASIS@NEWMAN
WATER TREATMENT PLANT – CURRENT LAYOUT AS OF 05.05.21
AQ-OAS-001-04
LYU
LYU
NEWMAN
OASIS
DESIGN:
DRAWN:
PROJECT:
CLIENT:
DRAWING TITLE:
DOCUMENT NO:
© Copyright AQUASOL February 2021. This document is and shall remain the property of Aquasol and may only be used for the purposes or demonstration in accordance with terms outlined in this document or attached documents. Unauthorised use of this document or design in any form whatsoever is prohibited, and Aquasol reserves the right to take legal action.
3REVISION:
A3SHEET SIZE: SCALE:
PAGE:4 OF 15
TYPE:ORTH / ISOM / P&ID
BALANCE TANK 2
BALANCE TANK 3
BALANCE TANK 1
CHLORINEIRRIGATION
BORE WATER 3
BORE WATER 2
FRESH WATER 3
BORE WATER 1
FRESH WATER 2
FRESH WATER 1
CHLORINATION PLANT(TRISTAR)
RO PLANT
32169
3080
9030
2080
3440
0
WP-1
19290
CO
MPAC
T DIR
T PAD
LOO
SE DIR
T
PUMP RUSCH7.5KW 50HZ
BP-0
OLD / DECOMMISSIONED DONGERS / FACILITIES
WP-3
WP-2
BRUSH / SCRUB
WP-4
24130
5556
WP-5
STORAGE CONTAINERPALLETSIBCSPARE 32 KL TANKS
RT320003000 X 3950
1
2
3SPARE 32 KL TANK
RT320003000 X 3950
RT320003000 X 3950
4
LOOSE DIRT
1
2
4
3
MAY REMAIN UNCHANGED.
SPARE TANKS, STORAGE CONTAINER AND PALLETS TO BE CLEARED AND RELOCATED FROM STP SITE.
TO BE USED AS STP SLUDGE TANK.
ANTENNAE TO REMAIN AS IS.
REQUIRED SITE / EARTHWORKS ACTION BY OASIS@NEWMAN
COMPACTED DIRT/EARTHWORKS
5
5 EARTHWORKS: COMPACTED DIRT AREA TO BE EXTENDED TOWARDS SOUTH-WEST BY ~ 8000.COMPACT DIRT AREA TO BE COVERED WITH SAND.
RADIO ANTENNAE
ACRONYM
BP
WP
DESCRIPTION
BOUNDARY POINT
WORKING POINT
OASIS SITE BO
UN
DAR
Y
OASIS SITE BOUNDARY
COMPACT DIRT PAD COMPACT DIRT PAD
LOOSE DIRT
8000
Certificate of Design Compliance 5878
BUILDING PERMIT 5878
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8
1:240
AQUASOLWater Treatment Solutions82-86 BERINGARRA AVEMALAGA WA 6090T: +61 8 9248 7533ACN: 157 831 411
DATE:01.06.21 OASIS@NEWMAN
WATER TREATMENT PLANT – CURRENT LAYOUT AS OF 05.05.21
AQ-OAS-001-04
LYU
LYU
NEWMAN
OASIS
DESIGN:
DRAWN:
PROJECT:
CLIENT:
DRAWING TITLE:
DOCUMENT NO:
© Copyright AQUASOL February 2021. This document is and shall remain the property of Aquasol and may only be used for the purposes or demonstration in accordance with terms outlined in this document or attached documents. Unauthorised use of this document or design in any form whatsoever is prohibited, and Aquasol reserves the right to take legal action.
3REVISION:
A3SHEET SIZE: SCALE:
PAGE:5 OF 15
TYPE:ORTH / ISOM / P&ID
T-202RT32000
T-201RT32000
T-203RT32000
CHLORINEIRRIGATION
BORE WATER 3
BORE WATER 2
FRESH WATER 3
BORE WATER 1
FRESH WATER 2
FRESH WATER 1
CHLORINATION PLANT(TRISTAR)
RO PLANT
32169
3080
9030
2080
3440
0
WP-1
19290
LOO
SE DIR
T
PUMP RUSCH7.5KW 50HZ
BP-0
OLD / DECOMMISSIONED DONGERS / FACILITIES
WP-3
WP-2
24130
8540
WP-5
CRANE ACCESS TO TANKS T-401 – T-406SUBMERSIBLE AERATOR REMOVAL FOR MAINTENANCE~ 5 YEAR INTERVAL
T-501SLUDGERT32000
3000 X 3950
1
LOOSE DIRT
1
2
4
3
MAY REMAIN UNCHANGED.
SPARE TANKS, STORAGE CONTAINER AND PALLETS TO BE CLEARED AND RELOCATED FROM STP SITE.
TO BE USED AS STP SLUDGE TANK.
ANTENNAE TO REMAIN AS IS.
REQUIRED SITE / EARTHWORKS ACTION BY OASIS@NEWMAN
5
COMPACT DIRT PAD
T-602
T-405SBR 5
T-406SBR 6
T-404SBR 4
T-403SBR 3
T-402SBR 2
OASIS SITE BO
UN
DAR
Y
OASIS SITE BOUNDARY
T-601
T-401SBR 1
40200
1444
7
ACRONYM
BP
WP
DESCRIPTION
BOUNDARY POINT
WORKING POINT
WP-4
4RADIO ANTENNAE
LOOSE DIRT
WP-2.1
8000
FENC
E
FENC
E
5556
EARTHWORKS: COMPACTED DIRT AREA TO BE EXTENDED TOWARDS SOUTH-WEST BY ~ 8000.COMPACT DIRT AREA TO BE COVERED WITH SAND.
6000
600
Certificate of Design Compliance 5878
BUILDING PERMIT 5878
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8
7 OF 77 OF 7
1:40 1:40
AQUASOLWater Treatment Solutions82-86 BERINGARRA AVE
MALAGA WA 6090
T: +61 8 9248 7533
ACN: 157 831 411
DATE:27.04.21 250 M3/HR WASTEWATER RECYCLING PLANT
SEA CONTAINER INTERNAL GENERAL ARRANGEMENT
AQ-OAS-001-02
LYU
LYU
NEWMAN
OASIS
DESIGN:
DRAWN:
PROJECT:
CLIENT:
DRAWING TITLE:
DOCUMENT NO:
© Copyright AQUASOL February 2021. This document is and shall remain the proper ty of Aquasol and may only be used for the
purposes or demonstration in accordance with terms outl ined in this document or attached documents. Unauthor ised use of this
document or des ign in any form whatsoever is prohibited, and Aquasol reserves the right to take legal action.
1REVISION:
A3SHEET SIZE: SCALE:
PAGE:
TYPE:ORTH / ISOM / P&ID
CV
CV
T1
FLOCCULANT
DOSE TANK
T2
CHLORINE DOSE
TANK
CHEMTROL BOARD
pH NTU FAC ANALYSIS
C V
C V
DOSE PUMPS
UV STERILIZER
F1
AQ6500 450MM
MEDIA FILTER
F2
AQ6500 450MM
MEDIA FILTER
F3
AQ6500 450MM
MEDIA FILTER
F4
AQ6500 450MM
MEDIA FILTER
F5
AQ6500 450MM
MEDIA FILTER
FP01
FP02
SLUDGE DRYING
BAG
SLUDGE DRYING
BAG – FILTRATE
RETURN PUMP
CONTROL PANEL
AIR
COMPRESSOR
SOLENOID
VALVE BANK
SCREENED
SEWERAGE
PUMP
SOLIDS
DISPOSAL BIN
ROTATING
SCREEN
ASSEMBLY 230
0
2200
PA
RT
ITIO
N W
AL
L
PA
RT
ITIO
N W
AL
L
7470 2190
800
RAW SEWERAGE FEED IN
SCREENED SEWERAGE
FROM POLISH TANKSTO IRRIGATION
FROM SLUDGE TANK
SLUDGE FILTRATE LIQUIER TO
BALANCE TANKS
Certificate of Design Compliance 5878
BUILDING PERMIT 5878
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8
1:45
AQUASOLWater Treatment Solutions82-86 BERINGARRA AVEMALAGA WA 6090T: +61 8 9248 7533ACN: 157 831 411
DATE:16.06.21 OASIS@NEWMAN
STP SEA CONTAINER ANCHOR DETAIL
AQ-OAS-003-01
LYU
LYU
NEWMAN
OASIS
DESIGN:
DRAWN:
PROJECT:
CLIENT:
DRAWING TITLE:
DOCUMENT NO:
© Copyright AQUASOL February 2021. This document is and shall remain the property of Aquasol and may only be used for the purposes or demonstration in accordance with terms outlined in this document or attached documents. Unauthorised use of this document or design in any form whatsoever is prohibited, and Aquasol reserves the right to take legal action.
1REVISION:
A3SHEET SIZE: SCALE:
PAGE:6 OF 15
TYPE:ORTH / ISOM / P&ID
LARGE AREA EXPOSED (SIDE)ASIDE = 35.31 M2
FW = 11600 KG
FW
300
2600
250
1450
VMAX = 28 KM.H-1
PSIDE = 89.53 N.M-2
RSIDE = 3161 M2
FW = 11600 KG
VMAX = 28 KM.H-1
http://www.bom.gov.au/climate/averages/tables/cw_007151.shtmlhttps://www.worldweatheronline.com/pilbara-weather-averages/western-australia/au.aspx
SIDE OVERTURN MOMENTOTMSIDE = 4577.36 N1.6x mBALLAST-REQUIRED = 84.54 KG
FW >> 1.6x mBALLAST-REQUIRED
NO ADDITIONAL TIEDOWNS REQUIRED
12190
40 MPa CONCRETE BASE250 X 300 X 2800504 KG
40 MPa CONCRETE BASE250 X 300 X 2800504 KG
STEEL SEA CONTAINER ANCHOR BRACKET
M16 THREAD RODCHEM ANCHOR
Certificate of Design Compliance 5878
BUILDING PERMIT 5878
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8
1:80
AQUASOLWater Treatment Solutions82-86 BERINGARRA AVEMALAGA WA 6090T: +61 8 9248 7533ACN: 157 831 411
DATE:16.06.21 OASIS@NEWMAN
STP SIDE ELEVATION PLAN
AQ-OAS-003-02
LYU
LYU
NEWMAN
OASIS
DESIGN:
DRAWN:
PROJECT:
CLIENT:
DRAWING TITLE:
DOCUMENT NO:
© Copyright AQUASOL February 2021. This document is and shall remain the property of Aquasol and may only be used for the purposes or demonstration in accordance with terms outlined in this document or attached documents. Unauthorised use of this document or design in any form whatsoever is prohibited, and Aquasol reserves the right to take legal action.
1REVISION:
A3SHEET SIZE: SCALE:
PAGE:7 OF 14
TYPE:ORTH / ISOM / P&ID
WASTEWATER RECYCLING PLANTFILTRATION SEA CONTAINER
POLISH TANK 1
SBR 1
FROM NORTHWEST
1800
3025
2440
4600 4600
3025
600 600 600 600 600
FROM SOUTHWEST
SBR 1SBR 2SBR 3SBR 4SBR 5SBR 6
TANK WEIGHT AT 80 VOL.% CAPACITY43,000 KG
FW = 43,000 KG
Certificate of Design Compliance 5878
BUILDING PERMIT 5878
4575
TANK DIA
0
90
180
M1N1
N1
100
292
5 TA
NK
WA
LL H
EIG
HT
340
0 TA
NK
HEIG
HT
PERSPECTIVE VIEW
M1
TOP VIEW
FRONT VIEW
270
N1
STORAGE TANK 1, 2, 3, 4, 5 & 6 - IT500001.2 - SMC93403
NOZZLE DN HEIGHT NOZZLE ANGLE DESCRIPTION CONNECTION
N1 80 100 0 NOZZLE 1 DN80 TABLE 'D' FLANGE
M1 455 ROOF 0 MANHOLE AND COVER
MANUFACTURER STD
APVD
11R
EV
ISIO
NS
CHKD
SIZE SHEET A3
SHEET OF
PRODUCT
SCALE DESCRIPTION
PRODUCT CODE DATE DRAWING No BY
MATERIAL
REV
SURFACE FINISH WALL THICKNESS
DATE
C
D
A
B
C
D
E
F
B
2
6
E
5 64
5432
A
1
1 3 THIS DRAWING IS THE COPYRIGHT OF COERCO. IT CANNOT BE COPIED IN PART OR FULL WITHOUT THE WRITTEN PERMISSION OF COERCO C
18MAY202193403 - STORAGE TANK 1, 2, 3, 4, 5 & 6
93403 - IT500001.2 - SMC
LLDPE
NTS
SMOOTH CREAM1.2SG A GT 18MAY2021 INITIAL RELEASE
93403
Certificate of Design Compliance 5878
BUILDING PERMIT 5878
4575
TANK DIA
0
90
180
M1N1
N1
N2
N2
100
100
292
5 TA
NK
WA
LL H
EIG
HT
340
0 TA
NK
HEIG
HT
PERSPECTIVE VIEW
M1
N2
TOP VIEW
FRONT VIEW
270
N1
STORAGE TANK 7 - IT500001.2 - SMC93403
NOZZLE DN HEIGHT NOZZLE ANGLE DESCRIPTION CONNECTION
N1 80 100 0 NOZZLE 1 DN80 TABLE 'D' FLANGE
N2 80 100 270 NOZZLE 2 DN80 TABLE 'D' FLANGE
M1 455 ROOF 0 MANHOLE AND COVER
MANUFACTURER STD
APVD
11R
EV
ISIO
NS
CHKD
SIZE SHEET A3
SHEET OF
PRODUCT
SCALE DESCRIPTION
PRODUCT CODE DATE DRAWING No BY
MATERIAL
REV
SURFACE FINISH WALL THICKNESS
DATE
C
D
A
B
C
D
E
F
B
2
6
E
5 64
5432
A
1
1 3 THIS DRAWING IS THE COPYRIGHT OF COERCO. IT CANNOT BE COPIED IN PART OR FULL WITHOUT THE WRITTEN PERMISSION OF COERCO C
18MAY202193403 - STORAGE TANK 793403 - IT500001.2 - SMC
LLDPE
NTS
SMOOTH CREAM1.2SG A GT 18MAY2021 INITIAL RELEASE
93403
Certificate of Design Compliance 5878
BUILDING PERMIT 5878
4575
TANK DIA
0
90
180
M1N1
N1
N2
N2
100
292
5 TA
NK
WA
LL H
EIG
HT
340
0 TA
NK
HEIG
HT
PERSPECTIVE VIEW
M1
TOP VIEW
FRONT VIEW
270
N1
STORAGE TANK 8 - IT500001.2 - SMC93403
NOZZLE DN HEIGHT NOZZLE ANGLE DESCRIPTION CONNECTION
N1 80 100 0 NOZZLE 1 DN80 TABLE 'D' FLANGE
N2 80 100 90 NOZZLE 2 DN80 TABLE 'D' FLANGE
M1 455 ROOF 0 MANHOLE AND COVER
MANUFACTURER STD
APVD
11R
EV
ISIO
NS
CHKD
SIZE SHEET A3
SHEET OF
PRODUCT
SCALE DESCRIPTION
PRODUCT CODE DATE DRAWING No BY
MATERIAL
REV
SURFACE FINISH WALL THICKNESS
DATE
C
D
A
B
C
D
E
F
B
2
6
E
5 64
5432
A
1
1 3 THIS DRAWING IS THE COPYRIGHT OF COERCO. IT CANNOT BE COPIED IN PART OR FULL WITHOUT THE WRITTEN PERMISSION OF COERCO C
18MAY202193403 - STORAGE TANK 8
93403 - IT500001.2 - SMC
LLDPE
NTS
SMOOTH CREAM1.2SG A GT 18MAY2021 INITIAL RELEASE
93403
Certificate of Design Compliance 5878
BUILDING PERMIT 5878