Perimeter Lit Mirror Install Instructions · Your LED ision Illuminated R 230 E. Lakewood Blvd....

3
Your LED Vision Illuminated R 230 E. Lakewood Blvd. • P.O. Box 8338 • Holland • MI • 49422-8338 Phone: 616-396-1355 • www.itc-us.com • [email protected] • 06/05/17 Perimeter Lit Mirror Install Instructions 69455.XXXX.YYK or 69455.CIR.XX.YYK Safety Instructions • Disconnect power before installing, adding or changing any component. • To avoid a hazard to children, account for all parts and destroy all packing materials. • Do not install any luminaire assembly closer than 6” from any combustible materials. • This power supply must be installed according to the National Electrical Code and local building codes. PARTS NEEDED: Backlit Mirror (Style varies) UL Recognized Power Supply (Installed on Mirror) Mounting Hardware CompelDownlight (Optional) Determine the installation location for your mirror. Verify local code and ADA height requirements before installing (see #6). Note, mirrors can be either surface mount or recessed. If surface mounting, simply mark the location of the wire exit and mounting holes. Cut a hole in the drywall and install a code compliant junction box. Next, pull the buildings’ wiring through and proceed to step 3. 1. TOOLS NEEDED (Customer Supplied): Toggle Bolts (optional) Tape Measure Electric Drill 22” Back Panel 2” Wire exit 12.6” 8.7” 4.6” 4.5” 1.6” 23.6” Wire exit 10.3” 6.3” 12.2” 20.5” Back Panel 4.2” 23.6” Wire exit 8.1” 13.1” 1.6” 2” 25.6” Back Panel 27.6” 39.4” 37.6” 3.2” 1.3”

Transcript of Perimeter Lit Mirror Install Instructions · Your LED ision Illuminated R 230 E. Lakewood Blvd....

Page 1: Perimeter Lit Mirror Install Instructions · Your LED ision Illuminated R 230 E. Lakewood Blvd. P.O. Box 8338 Holland MI 49422-8338 Phone: 616-396-1355  sales@itc-us.com 06/05/17

Your LED Vision IlluminatedR

230 E. Lakewood Blvd. • P.O. Box 8338 • Holland • MI • 49422-8338

Phone: 616-396-1355 • www.itc-us.com • [email protected] • 06/05/17

Perimeter Lit Mirror Install Instructions69455.XXXX.YYK or 69455.CIR.XX.YYK

Safety Instructions • Disconnect power before installing, adding or changing any component.• To avoid a hazard to children, account for all parts and destroy all packing materials.• Do not install any luminaire assembly closer than 6” from any combustible materials.• This power supply must be installed according to the National Electrical Code and local building codes.

PARTS NEEDED:

Backlit Mirror (Style varies)

UL Recognized Power Supply

(Installed on Mirror)

Mounting Hardware

Compel™ Downlight (Optional)

Determine the installation location for your mirror. Verify local code and ADA height requirements before installing (see #6). Note, mirrors can be either surface mount or recessed. If surface mounting, simply mark the location of the wire exit and mounting holes. Cut a hole in the drywall and install a code compliant junction box. Next, pull the buildings’ wiring through and proceed to step 3.

1.

TOOLS NEEDED (Customer Supplied):

Toggle Bolts (optional) Tape Measure Electric Drill

22”Back Panel

2”

Wire exit

12.6”

8.7” 4.6”

4.5”

1.6”

23.6”

Wire exit

10.3”

6.3”

12.2”

20.5”Back Panel

4.2”

23.6”

Wire exit

8.1”

13.1”

1.6” 2”

25.6”Back Panel

27.6”

39.4”

37.6”

3.2”

1.3”

Page 2: Perimeter Lit Mirror Install Instructions · Your LED ision Illuminated R 230 E. Lakewood Blvd. P.O. Box 8338 Holland MI 49422-8338 Phone: 616-396-1355  sales@itc-us.com 06/05/17

Your LED Vision IlluminatedR

230 E. Lakewood Blvd. • P.O. Box 8338 • Holland • MI • 49422-8338

Phone: 616-396-1355 • www.itc-us.com • [email protected] • 06/05/17

ADA requires that “Mirrors shall be mounted with the bottom edge of the reflecting surface no higher than 40 in (1015mm) above the finished floor1.” For lit mirrors this means the dimension is to the inner most edge of the lit portion.

6.

Using the wiring diagram at the right, wire the power supply on the mirror to the buildings power. The light on the mirror will already be wired to the power supply. Test light to ensure all connections work.Feed the wires back through the hole and slide the mirror onto the screws.

4.

= Wire Nuts or Terminal Block

AC DC

120V - 24V Class 2

Power Supply

Red (+) Black (-)AC Power

Blue (N)

Brown (L)

0-10VDimmer

Blue (+)

White (-)

If recessing the mirror, measure the back panel of the mirror and mark size in the desired install location. There is a minimum of 3/4” between the outside edge of the mirror and the perim-eter of the back panel, so the hole can be slightly larger than the back panel. Cut out the drywall. Additional blocking may be needed behind each key hole slot location and should be installed by a qualified contractor.

2. Install mounting screws into pre-marked holes. It is highly rec-ommended that all mirrors be installed in contractor supplied blocking, however, drywall anchors may be used if no blocking is available. Drywall anchors should be sized appropriately to support the weight of the mirror. For added safety, ITC recommends any mirror over 40 lbs, only be installed in blocking. If blocking is not available, drywall tog-gle bolts (not provided) must be used and sized accordingly for the weight of the mirror.

3.

D

DETAIL D

SCALE 2 : 5

D

DETAIL D

SCALE 2 : 5

If using the Compel optional downlight, snap the magnetic mounting clips onto the light and center on the bottom of the back panel, plug the light into the plug on the mirror. Turn on power and confirm mirror is in working order.

5.

40”

NO

Finished floor

40”

YES

1 - 2010 ADA Standards 603.3 https://www.ada.gov

Page 3: Perimeter Lit Mirror Install Instructions · Your LED ision Illuminated R 230 E. Lakewood Blvd. P.O. Box 8338 Holland MI 49422-8338 Phone: 616-396-1355  sales@itc-us.com 06/05/17

Your LED Vision IlluminatedR

230 E. Lakewood Blvd. • P.O. Box 8338 • Holland • MI • 49422-8338

Phone: 616-396-1355 • www.itc-us.com • [email protected] • 06/05/17

TROUBLESHOOTING7.The mirror doesn’t light:A. Check the connection between the mirror and buildings wiring. The neutral line of the building should be wired to the neutral line on the mirror and the load line should be wired to the load line on the mirror.

B. Verify that there is power coming out of the power supply. You will need to remove the back panel in order to do this.

C. Verify that there is120V power coming out of the buildings junction box.

D. Verify that the tape light has not been unplugged from the power supply.

E. If the mirror still doesn’t light a new mirror will be sent as a replacement if it’s still under warranty.

Part of the mirror won’t light:F. This is mostly likely due to a bad LED, however, follow the previous steps to make sure all connections are done correctly.

G. If the portion still won’t light, the mirror will need to be replaced.

The lighting looks discolored:H. This can be caused by dust settling in the mirror on the tape light. The dust can be cleaned off using an electronic spray cleaner.

A

B

C D

H

Remove screwsto detach back panel

For warranty information please visit our website, www.itc-us.com.