Transcript of Performance Tuning and Databases
![Page 1: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/1.jpg)
Tom Hamilton – America’s Channel Database CSE
Performance Tuning and Databases
1
![Page 2: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/2.jpg)
Agenda
Tuning MethodologyPerformance Analysis
– What causes poor performance– How to identify the causes– How to fix the causes
Performance Analysis ToolsOracle Best PracticesSQL Server Best PracticesNetApp Controller Best PracticesExamplesProtocol Comparisons
2
![Page 3: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/3.jpg)
Introduction
Performance tuning is not a science!
It is an art form!!!!
It is about finding the bottleneck(s)!
3
![Page 4: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/4.jpg)
Tuning Methodology
Check for Known Hardware and Software Problems
Consider the Whole SystemMeasure and Reconfigure by LevelsChange One Thing at a TimePut Tracking and Fallback Procedures in
Place Before You StartDo Not Tune Just for the Sake of TuningRemember the Law of Diminishing Returns
4
![Page 5: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/5.jpg)
HP-UX NFS Performance with OracleDatabase 10g Using NetApp Storage – TR3557
5
![Page 6: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/6.jpg)
Top 5 Performance Bottlenecks
Disk bottleneckFC-AL Loop bottleneckCPU/domain bottleneckNetworking and target card limitsClient side thread parallelism
6
![Page 7: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/7.jpg)
Top 5 Performance Bottlenecks
7
Disk Bottleneck
Shelf Loops
Storage CPU/Domain
Network (FC/Ethernet)
Server Threads
![Page 8: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/8.jpg)
Drive Type and IOPS
8
![Page 9: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/9.jpg)
Diagnosing Disk Throughput Bottlenecks
9
Bottleneck: Disks have data throughput and IOPS limitations
Symptoms: High latency or inability to add more load on a particular volume
Diagnosis: Use statit to monitor disk utilizationDisk bottleneck - If disk utilization is >70% *and* high data transfer rates or transfers per disk
disk ut% xfers ureads--chain-usecs writes--chain-usecs/vol0/plex0/rg0:0b.17 99 297.22 297.22 1.00 20034 0.00 .... . 0b.18 99 292.55 292.55 1.00 19960 0.00 .... . 0b.19 99 294.75 294.75 1.00 20180 0.00 .... .0b.20 99 294.15 294.15 1.00 19792 0.00 .... . 0b.21 99 294.76 294.76 1.00 19632 0.00 .... . 0b.22 99 293.70 293.70 1.00 20341 0.00 .... .
Approx IOPS
SAS/FC Disks 20-260
SATA 20-80
![Page 10: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/10.jpg)
Diagnosing Disk Throughput Bottlenecks
Solutions:Use flexible volumes with large aggregatesAdd more drives to the aggregateRedistribute load on to lightly loaded disksFlashCache
10
![Page 11: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/11.jpg)
Diagnosing Disk Loop Saturation
11
Bottleneck: Disk Loop has throughput limitations Each loop can support up to 2Gbit~180MB/s, 4Gbit =
~360MB/s
Symptoms: High response times to requests on one or more volumes
Inability to add more load to one or more volumes RAID reconstruction / scrub
![Page 12: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/12.jpg)
Diagnosing Disk Loop Saturation
12
Diagnosis: High disk utilization can indicate loop limits
Use statit to monitor disk utilizationLoop
Saturation - If disk utilization is >70% but low disk tput(67 * 31.5 * 4K = 8 MB/s per disk) *and* high data transfer rates on a loop
disk ut% xfers ureads--chain-usecs writes--chain-usecs /vol0/plex0/rg0:
0b.16 0 0.03 0.02 10.00 5250 0.01 10.00 0 0b.17 97 66.91 66.90 31.54 1774 0.01 10.00 0 0b.18 96 67.06 67.05 31.49 1552 0.01 10.00 0 0b.19 95 66.99 66.98 31.54 1472 0.01 10.00 0 0b.20 94 67.05 67.04 31.48 1453 0.01 10.00 0
![Page 13: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/13.jpg)
Diagnosing Disk Loop Saturation
13
Solutions: Add more Disk loops Add Dual-path on single controller or Multipath HA on
CFO(Requires ONTAP 7.1.1 or greater) Redistribute disks in a volume/raid group across loops
![Page 14: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/14.jpg)
Diagnosing CPU/Domain Bottleneck
14
Bottleneck: CPU(s) have more work than they can handle
Symptoms: High latency or Client side sluggishness sysstat reports CPU utilization > 95%
Diagnosis: Use statit to check CPU StatisticsLook for CPU utilization > 95% on 1P, >190% on 2P, >350% on 4P
CPU Statistics 109.921938 time (seconds) 100 % 216.140218 system time 197 %
2.582292 rupt time 2 % 445061 rupts x 6 usec/rupt)
213.55792 non-rupt system time 194 % 3.703658 idle time 3 %
![Page 15: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/15.jpg)
Diagnosing CPU/Domain Bottleneck
Diagnosis: If CPU not high enough, may indicate “domain” bottleneck
Controller processing is split into ‘domains’ such as - RAID, Networking, Storage, etc.
Work associated with a given domain can only run on one processor at any given time
Improper management of filer could result in all work that needs to be done is in one domain
Not a common problem
15
![Page 16: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/16.jpg)
Diagnosing CPU/Domain Bottleneck
16
Diagnosis: Use sysstat –m option or statit to check domain utilization
Look for ‘total’ domain time > 900,000 usec(90%)
cpu0 cpu1 total idle 16952.55 16740.97 33693.52kahuna 456550.84 465228.22 921779.17Network 293882.11 282281.51 576163.53 storage 30605.83 30353.09 60958.92 Exempt 121252.02 121671.95 242923.97raid 70162.66 70080.22 140242.89 target 214.24 204.22 418.46
92% Utilization
![Page 17: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/17.jpg)
Diagnosing CPU Bottleneck
Solutions: Use FlexShare to prioritize workloads Stagger workload to non-peak times Reschedule transient activities such as raid
reconstruct, scrubs etc. Load balance by migrating to other filers If high network traffic, look for
- Misbehaving clients- Bad mounts- Virus scanning activity
Upgrade to a higher performing filer FlashCache?
17
![Page 18: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/18.jpg)
Diagnosing Network and Target Adapter Limits
Gigabit Ethernet 10 Gb Ethernet FC 2Gb target FC 4Gb target
80 MB/s 800 MB/s 180 MB/s 360 MB/s
18
Bottleneck: Network and Target adapters have throughput and IOPS limitations per port
Symptoms: Poor responsiveness to clients on a given network and inability to add more load to filerDiagnosis: Use statit or ifstat to monitor traffic on each port
Look for the port limits, Ex. Gigabit Ethernet Interface Network Interface Statistics (per second)
iface side bytes packets multicasts errors collisions pkt drops e0 recv 595.95 7.65 1.67 0.00 0.00 xmit 679.24 6.46 0.00 0.00 0.00 e9a recv 473754.48 3536.66 2.24 0.00 0.00 xmit 121823577.22 40645.67 0.00 0.00 0.00 e9b recv 471987.25 3523.48 2.24 0.00 0.00 xmit 60596317.35 40493.83 0.00 0.00 0.00 e11a recv 477358.49 3563.57 2.24 0.00 0.00
xmit 61286194.79 40954.82 0.00 0.00 0.00
![Page 19: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/19.jpg)
Diagnosing Network/Target Adapter BottleneckSolutions:
Use Link aggregation (trunking) to increase network bandwidth
Add more adapters or multi-ported adapterRoute traffic through underutilized interfacesUpgrade to 10 Gb network interface or 4 Gb FC
target interface
19
![Page 20: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/20.jpg)
Diagnosing Client Side Thread Parallelism
Problem: Applications see poor throughput but controller doesn’t show any bottleneck
Symptoms: Storage system not fully utilizedHigh I/O wait times at the client
20
![Page 21: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/21.jpg)
Diagnosing Client Side Thread Parallelism
Diagnose: Use sysstat to check CPU, Disk, network utilization
CPU NFS CIFS HTTP Total Net kB/s Disk kB/s Tape kB/s Cache Cache CP CP Disk DAFS FCP iSCSI FCP kB/s in out read write read write age hit time ty util in out 48% 0 0 0 1141 1 1 24871 36846 0 0 2 100% 61% 23f 30% 0 1141 0 50221 19861 44% 0 0 0 1112 1 1 24937 34109 0 0 2 100% 63% 22f 28% 0 1112 0 44818 20359 51% 0 0 0 1192 1 1 23924 42640 0 0 2 100% 67% 26f 31% 0 1192 0 53965 25354 29% 0 0 0 761 1 1 16554 21744 0 0 2 100% 39% 14 20% 0 761 0 27403 12942 11% 0 0 0 415 1 1 6134 4650 0 0 2 99% 11% 5 7% 0 415 0 7077 4890
Typically single thread of execution from the client (ex. cp and dd)
Solutions: Application Tuning - More threads - Increase transfer sizeTune client or target throttles in case of FCP
21
![Page 22: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/22.jpg)
What is not a Bottleneck?
NVRAM– Provides data integrity in case of controller failure – Only logs transactions before committing to disk– NVRAM is not a write cache
22
![Page 23: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/23.jpg)
Key Takeaways
Performance Monitoring– Adhere to performance monitoring methodology
Focus on latency monitoring Recognize performance trends
Performance Analysis– Identify common performance bottlenecks
Disk bottleneck FC-AL Loop bottleneck CPU/domain bottleneck Networking and target card limits Client side thread parallelism
– Understand possible solutions
23
![Page 24: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/24.jpg)
Performance Tuning Analysis Tools
Sysstat Statit - na_statit.1a.htm statit_explained.pdf Perfstat / Latx SIO Stats https://now.netapp.com/eservice/toolchest Quest Spotlight OnCommand InSight Balance
DBTuna
24
![Page 25: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/25.jpg)
Sizing Tools
Database Sizer– Statspak / AWR– SQL Performance Analyzer– Perfstat
Unified Sizer
25
![Page 26: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/26.jpg)
NetApp Controller Best Practices
Aggregates – TR-3437– Disks (Number, Size, Type)
15k Disks
– Disk loopsIMT
– Network Adapters– FC Adapters
WAFL - WAFL OverviewData OnTap - version
26
![Page 27: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/27.jpg)
Before PAM-IIDisk I/O for 30 Disk SATA Aggregate
31
![Page 28: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/28.jpg)
After PAM-II Installation – TR3832Disk I/O for 30 Disk SATA Aggregate
32
20 Minutes
After Install
Cache 90% Populated
The First 30 minutes of operationPAM-II is delivering I/O the equivalent of: 1 Shelf 15K FC or 5 Shelves of SATA
![Page 29: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/29.jpg)
Deciding Between Flash Cache & SSD
33NetApp Confidential – Limited Use
Flash Cache(Intelligent Read Caching)
Good Fit When …
SSDs in DS4243(Persistent Storage)Good Fit When …
Random read intensive workload Random read intensive workload
Improving average response time is adequate Every read must be fast
Active data is unpredictable or unknown
Active data is known and fits into SSD capacity
Administration free approach desired Active data is known, is dynamic, and ongoing administration is okay
Minimizing system price is important Upside of write acceleration desired
Accelerating an existing HDD configuration is desired
Performance must be consistent across failover events
© 2010 NetApp. All rights reserved. 33NetApp Confidential – Limited Use
![Page 30: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/30.jpg)
Product Information – TR3938
DS4243 SSD Option– 24 x 100GB SSD per shelf
– Requires Data ONTAP 8.0.1+ Both 7-Mode and Cluster-Mode supported
– Shelf setup is exactly the same as with SATA or SAS
Available in full shelf increments only (24 drives):– Add-on: DS4243-SL02-24A-QS-R5
– Configured: DS4243-SL02-24A-R5-C
– Individual drives may be parts ordered (X441A-R5) Formerly X442A-R5
Platforms:– Supported:
FAS/V3160, 3170, 6000 series, 3240, 3270, and 6200 series
– Not supported: FAS/V2020, 2040, 2050, 3140, 3210, and all 3000 series
34NetApp Confidential – Limited Use© 2010 NetApp. All rights reserved. 34NetApp Confidential – Limited Use
![Page 31: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/31.jpg)
Performance - Sequential
Sequential I/O throughput per drive
35NetApp Confidential – Limited Use© 2010 NetApp. All rights reserved. 35NetApp Confidential – Limited Use
Large Seq. Read Large Seq. Writes0
20
40
60
80
100
120
15K rpm FC driveSSD
MB
/se
c p
er
Dri
ve
![Page 32: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/32.jpg)
Storage Performance GuidelinesTR-3437Adequate spindle counts
– Aggregate– Traditional volumes– SATA considerations
SnapMirror / SnapVault considerations– Stagger schedules– Off-peak workload time scheduling– Throttle bandwidth
Multipath HALUN Alignment
36
![Page 33: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/33.jpg)
HP-UX NFS Performance with OracleDatabase 10g Using NetApp Storage – TR3557
37
![Page 34: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/34.jpg)
HP-UX NFS Performance with OracleDatabase 10g Using NetApp Storage – TR3557
38
HP-UX Server Tuninghttp://docs.hp.com/en/5992-4222ENW/5992-4222ENW.pdf Tune-N-Toolshttp://software.hp.com/portal/swdepot/displayProductInfo.do?productNumber=Tune-N-Tools HP-UX TCP/IP Performance White Paperhttp://docs.hp.com/en/11890/perf-whitepaper-tcpip-v1_1.pdf
![Page 35: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/35.jpg)
HP-UX NFS Performance with OracleDatabase 10g Using NetApp Storage – TR3557
HP-UX Kernel ParametersOracle Initialization ParametersNFS Mount Optionshttp://now.netapp.com/Knowledgebase/solutionarea.asp?id=kb7518
HP-UX NFS Kernel ParametersHP-UX Patch Bundles
39
![Page 36: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/36.jpg)
AIX DB2 Performance Protocol Comparison on NetApp, TR-3581
40
![Page 37: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/37.jpg)
AIX Oracle Performance Protocol Comparison on NetApp, TR-3871
41
![Page 38: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/38.jpg)
Oracle 10g Performance Protocol Comparison on SUN Solaris 10 – TR3496
42
![Page 39: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/39.jpg)
Oracle 10g Performance Protocol Comparison on SUN Solaris 10 – TR3496
43
![Page 40: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/40.jpg)
Oracle 11g R2 Performance Protocol Comparison on RHEL 5 – TR3932
44
![Page 41: Performance Tuning and Databases](https://reader031.fdocuments.in/reader031/viewer/2022020716/5535f4284a795919158b478d/html5/thumbnails/41.jpg)
Summary
NetApp ControllerHostNetworkDatabase Settings
FIND THE BOTTLENECK!!
45