Performa Cv Control Valves - Blaulain · 2011-06-30 · ™ Cv Control Valves 273 and 278...
Transcript of Performa Cv Control Valves - Blaulain · 2011-06-30 · ™ Cv Control Valves 273 and 278...
COMMERCIAL CONTROL VALVES
Performa™ Cv Control Valves273 and 278 Configurations
Logix™ Series742 Time Clock• Simple, economic electronic
time clock (chronometric)• 7- or 99-day regeneration
setting• 12-volt operation• Filter or conditioner setting
in one control
• Fully programmable cycle times
• Salt setting in 1-pound increments
• Operates 255, 263, 268, 273, 278, and Magnum® IT with one controller
762 Demand• Simple, economic electronic
demand (volumetric)• Calendar override• 12-volt operation• 28-day variable reserve• Automatic capacity
calculations
• Fully programmable cycle times
• Salt setting in 1-pound increments
• Operates 255, 263, 268, 273, 278, and Magnum IT with one controller
Pentair Water® offers a full range of Autotrol® Control Valves to meet a wide range of water conditioning applications.
764 DemandSame features as the 762, plus:
• Multi-tank applications (twin alternating, multi-tank parallel)
• Control lockout
• Remote regeneration
COMMERCIAL CONTROL VALVES
Performa™ Cv Control Valves273 and 278 Configurations
Electrical Controller Operating Voltage 12 Volt – AC (Requires use of Pentair Water®-supplied transformer)
Input Supply Frequency 50 or 60 Hz (Controller configuration dependent)
Motor Input Voltage 12 Volt – AC
Controller System Power Consumption 3 Watts average
Transformer – All Controllers All Controllers require the use of a Pentair Water-supplied transformer.
Transformer Output Voltage 12 Volt – AC 400mA
Transformer Input Options 115 Volt – AC 50/60 Hz; 230 Volt – AC 50/60 Hz; 100 Volt – AC 50/60 Hz
Transformer Plug Options Indoor North American Plug Taiwan/Korea Plug
Outdoor North American Australian Plug (UL Listed for outdoor use) United Kingdom Plug
Japanese Plug Mainland Europe Plug
Additional transformers may be available – call for more information.
Specifications
Design Specifications/RatingsValve Body Glass-filled thermoplastic – NSF Listed materialRubber Components Compounded for cold water – NSF Listed materialValve Materials Certification WQA Gold Seal Certified to ORD0902 and NSF/ANSI 44 Rated component for material safety
Weight (Valve with Control) 5.34 Ibs (2.42 kg)Recommended Operating Pressure 20 - 120 psi (1.38 - 8.27 bar) Canada 20 - 100 psi (1.38 - 6.89 bar)
Hydrostatic Test Pressure 300 psi (20.69 bar)Water Temperature 35° - 100°F (2° - 38°C)Ambient Temperature* 35° - 120°F (2° - 48.9°C)
*Recommend use of outdoor cover for direct sunlight applications.
OptionsTurbine for Demand Systems Internal Standard Autotrol® 1-inch (25 mm) turbineBypass Valve, Model 1265 Thermoplastic, 1-inch flow path
Bypass Fitting Kits:Copper, Sweat Tube Adapter 1-1/4-inches, 1-inch or 3/4 inch (32 mm, 25 mm or 19 mm)CPVC, Solvent Weld Tube Adapter 1-inch or 3/4-inch (25 mm or 19 mm)Plastic NPT or BSPT Pipe Adapter 1-inch male or 3/4-inch male (25 mm or 19 mm)Stainless Steel NPT or BSPT Pipe Adapter 1-inch male or 3/4-inch male (25 mm or 19 mm)Brine Refill Controls .33 gpm (1.25 lpm) fixed; .74 gpm (2.8 lpm) fixed; 1.3 gpm (4.92 lpm) fixedCompatible with Regenerants/Chemicals Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite†, sodium hydroxide†, hydrochloric acid†, chlorine†† and chloramines††
†See owners manual for specific concentrations. ††Valve for use on potable water supply.
SERV
ICE FL
OW –
Cv =
6.5
B
ACKW
ASH
FLOW
– C
v =
4.00
LWR 5730
5 1510 20 25 30 350
2.3 3.4 4.51.10 5.7 6.8 7.9
2.00
1.75
1.50
1.25
1.00
0.75
0.50
0.25
0.00
30
25
20
15
10
5
0
Flow Rate (m3/hr)
Flow Rate in Gallons Per Minute
Pre
ssur
e D
rop
in P
SI P
ressure Dro
p (B
ar)
DimensionsValve ConnectionsTank Thread 2-1/2-inches – 8, male Inlet/Outlet Threads 1-3/4-inches – 12 UNC-2A maleDrain Line 3/4-inch NPT, maleBrine Line 3/8-inch NPT, maleDistributor Tube Diameter 1.050 inches (27 mm) Distributor Tube Length 1/2 ± 1/2-inches (13 ± 13 mm) above top of tank
Outline Dimensions
Logix™ Series Controller Flow Rate Characteristics Backwash Flow Control Table
*Backwash flow controls sized for 5.0 gpm/ft2.
NOTE: External drain line flow controls available for flow rates from 1.3 gpm (4.9 lpm) to 20 gpm (75.7 lpm).
Backwash Flow Rate Flow Rate Number* (gpm) (lpm)
9 2.2 8.3
10 2.7 10.2
12 3.9 14.76
13 4.5 17.0
14 5.3 20.0
PerformanceFlow Rates (Valve Only)Service @ 15 psi (1.03 bar) drop 25.0 gpm (5.7 m3/h)Backwash @ 25 psi (1.72 bar) drop 20.0 gpm (4.5 m3/h)Service Cv = 6.50 (Kv = 5.6)Backwash Cv = 4.00 (Kv = 3.5)
Units A B C D E F G H I
inchescm
14.937.8
7.819.9
7.117.9
8.521.5
5.012.7
5.313.5
5.814.8
3.48.7
3.48.7
FG
CB
A
E
D
IH
FG
CB
A
E
D
IH
FG
CB
A
E
D
IH
Injector* PerformanceLogix ™ Series Controllers
NOTE: Actual injector performance is dependent on the resin used, tank geometry, elevated drain, etc. This injector data was taken using an empty tank (no resin).
Gal
lons
per
Min
ute
bar
PS I
0.16
0.14
0.12
0.10
0.08
0.06
0.04
0.02
0.00
m3mm /33 hr
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00 LWLW R 6151
20
2 3.5 5 6 7.5
40 60 80 100 120
Injector “H” (Ligh t Purpl e)eeFor 9-inch Tankskk
Gal
lons
per
Min
ute
bar
PS I
0.3 0
0.2 0
0.1 0
0.0 0
m3mm /33 hr1.5 0
1.2 5
1.0 0
0.7 5
0.5 0
0.2 5
0.0 0 LWRWRLL 6164
20
2 3.5 5 6 7.5
40 60 80 100 120
Injector “L” (Oran ge)gegeF or 13- and 14-inch T anks
Gal
lons
per
Min
ute
bar
PS I
0.25
0.20
0.15
0.10
0.05
0.00
3m /33 hr
1.20
1.00
0.80
0.60
0.40
0.20
0.00 LWRWRLL 6151
20
2 3.5 5 6 7.5
40 60 80 100 120
Injector “K” (Pi nk)kkFor 12-inch Tank sankank
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00
3.20
2.80
2.40
2.00
1.60
1.20
0.80
0.40
0.00
Gal
lons
per
Min
ute
bar
PS I
m3mm /33 hr
20 40 60 80 100 120
Inject or “Q” (Purple)For 18-inch Tank sankank
2 3.5 5 6 7.5
0.50
0.40
0.30
0.20
0.10
0.00G
allo
ns p
er M
inut
e
bar
PSI
m3mm /33 hr2.40
2.00
1.60
1.20
0.80
0.40
0.0020 40 60 80 100 120
Inject or “N ” (Green )Fo r 16-inch Ta nk snknk
2 3.5 5 6 7.5
Gal
lons
per
Min
ute
bar
PS I
0.1 8
0.16
0.1 4
0.12
0.10
0.0 8
0.0 6
0.0 4
0.0 2
0.0 0
m3mm /33 hr
0.80
0.60
0.40
0.20
0.00 LWR615LWR615 1
20
2 3.5 5 6 7.5
40 60 80 100 120
Injector “J““ ” (L ight B lue )luelueFor 10-inch Tankskk
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00
3.50
3.00
2.50
2.00
1.50
1.00
0.50
0.00
Gal
lons
per
Min
ute
bar
PS I
m3mm /33 hr
20 40 60 80 100 120
Inject or “R” (Dark Grey )(Dark Grey(Dark GreyFor 21-inch Tank sankank
2 3.5 5 6 7.5
TOTAL BRINE DRAW RINSE
TOTAL BRINE DRAW RINSE
TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE
TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE
TOTAL BRINE DRAW RINSE