People MCCB
description
Transcript of People MCCB
-
MOULDED CASECIRCUIT BREAKER
C
People Electric Appliance serves for people.
ISO14001 OHSAS18001ISO9001
-
RDM1 MOULDED CASE CIRCUIT BREAKER
APPLICATION
RDM1 series of moulded case circuit breaker is a new type product developed and manufacturedby adopting international advanced technology. It is supplied with rated insu lation voltage 800V and used for circuit of AC50Hz, rated operating voltage AC 400V or below rated operation currentup to 800A for infrequent changing over and starting of the motors. Equipped w ith t he protectiondevices for over-current, short circuit and undervoltage, the product is capable of preventingdamage of circuits and supplying units The product conforms to IEC60947-2.
SPECIFICATION
TypeRated
current(A)
Num-ber ofPoles
Ratedinsula-
tionvoltage
(V)
Ratedoperat-
ingvoltage
(V)
Arcing-over
distance(mm)
Ultimateshort
circuitbreakingcapacity
(KA)
Serviceshort
circuitbreakingcapacity
(KA)
Operationperfor-mance
ON OFF
RDM1-63LRDM1-63MRDM1-100CRDM1-100LRDM1-100MRDM1-100HRDM1-225CRDM1-225LRDM1-225MRDM1-225HRDM1-400CRDM1-400LRDM1-400MRDM1-630CRDM1-630LRDM1-630MRDM1-630HRDM1-800MRDM1-800H
6,10,16,20,25,32,40,
50,63
10,16,20,25,32,40,50,63,80,
100
100,125160,180
200,
225,250315,350
400
400500630
630,700800
3P,4P 660V 380V
000
0( 50)0( 50)0( 50)
50505050505050
100100100100100100
25502535508525355085355065355065
10065
100
18351822355018223550253542253542654265
1500 8500
1000 7000
1000 4000
RDM1-63L 3P
RDM1-225L 3P
RDM1-400 3P
ACCESSORIES FOR MCCB
Alarm contact Under voltage release
Manual operation Auxiliary contact Shunt release
MOULDED CASE CIRCUIT BREAKER
A C-01
-
APPLICATION
RDM11 MOULDED CASE CIRCUIT BREAKER
RDM11 moulded case circuit breake r is one o f the most advanced type breakers i n the world, which adopts international advanced design and manufacture technology. They are suitable for shortcircuit and overload protection for circuit of AC 690V 50/60Hz, rated current from 12.5A to 630A.It takes protective effect when mouse cage motors non-fre quent star t, breakin g off working and protecting overload, short circuit and lacking voltage.
TRIPPING CHARACTERISTICS OF MCCB
Rated current of
release(A)
In 63
63 In 100
100 In 630
Thermodynamic release (ambient temp+40 )
1.05In(cold state)operative time (h)
1.30In(heat state)operative time (h)
1
2
2
1
2
2
Operational currentof magneticrelease(A)
10In 20%
10In 20%
5-10In 20%
Rated current of
release(A)
12.5 In 400
Thermodynamic release (ambient temp+40 )
2
1.0In(cold state)operativetime (h)
1.20In(heat state)operativetime (h)
1.50In(heat state)operativetime (h)
2 4min
7.20In(coldstate)
operativetime (h)
2S Tp 10S
Operational currentof magneticrelease(A)
12In 20%
SPECIFICATION
RDM11-100N 3P
RDM11-250N 4P
RDM11-630N 3P
Ratedcurrent
(A)Type Poles
Ratedinsulatingvoltage
(V)
Ratedoperatingvoltage
(V)
Arcingover
distance(mm)
Serviesshort
circuitbreakercapacity
Ultimateshort
circuitbreakercapacit
Operatingperfor-mance(times)
RDM11-100DRDM11-100NRDM11-100HRDM11-100LRDM11-160DRDM11-160NRDM11-160HRDM11-160LRDM11-250DRDM11-250NRDM11-250HRDM11-250LRDM11-400DRDM11-400NRDM11-400HRDM11-400LRDM11-630DRDM11-630NRDM11-630HRDM11-630LRDM11-1250DRDM11-1250NRDM11-1250HRDM11-1250LRDM11-1600DRDM11-1600NRDM11-1600HRDM11-1600L
12.5,16,20,25,32,40,50,63,
80,100
16,20,25,32,40,50,
63,80,100,125,160
160,180,200,225,
250
200,225,250,300,315,400
315,350,400,500,600,630
3,4 950 690 0
182570150253670150253670150354570150354570150506585160506585160
182570150253670150253670150354570150354570150506585160506585160
1500 8500
1500 7000
1000 7000
1000 4000
1000 4000
630,700800,1000,
1250
800,1000,1250,1600
500,2500
500,2500
MOULDED CASE CIRCUIT BREAKER
RDM11-250N
RDM11-100N
A C-02
-
PNE-100 2P
PNE-100 3P
PNE-250 3P
Type
Number of Poles
Rated Current In(A)
Rated Operating Voltage Ue(V) AC50/60Hz
Rated Insulation Voltage Ui(V)
Rated (kV)Uimp
Breaking Capacity
(kA ms)
IEC60947-2
Icu AC
220/240V
380V
400
220/240V
380V
400V
240V
480V
Ics%Icu
ACBreaking Capacity(kA)(NEMA-ABI)(HIC)
Mechanical Life
Electrical Life
OverloadCurrentProtection(A)
Hot protection
Magnetism protection
Dimensions(mm)
L H D
PNE 60E PNE 100F PNE 100H PNE 250
3 3 3 3
15,20,25,30,40,50,
60
15,20,25,30,40,50,60,75,80,
100
15,20,25,30,40,50,60,75,80,
100
125,160225,250
500
500
6
10
7.5
7.5
25%
25%
25%
-
-
8.500
4.000
Fixed
Fixed
500
500
6
25
10
7.5
25%
25%
25%
-
-
8.500
4.000
Fixed
Fixed
500
500
6
50
30
20
25%
25%
25%
25
10
8.500
4.000
Fixed
Fixed
500
500
6
85
18
15
50%
50%
50%
25
10
8.500
4.000
Fixed
Fixed
75 13060
75 13060
75 13060
105 16565
PNE MOULDED CASE CIRCUIT BREAKER
APPLICATION
PNE moulded case circuit break er is one of the most advanced type breakers in the world, which ado pts international advanced design and manufactur technology. They aresuitable for short circuit and overload protection for circuit of AC 690V 50 / 60Hz, rated currentfrom 15A to 160A. Its rated insulation voltage is 690V. It can make and break the non-frequen t c ircui t in the normal cond itio ns. It takes protective effect when mouse cagemotors no n-fr equent st arting or breaking off working and protecting overload, shortcircuit and lacking voltage. It complies with IEC60947-2.
MAIN TECHNICAL SPECIFICATION
MOULDED CASE CIRCUIT BREAKER
PNE-100
PNE-250
A C-03
-
Type
RDM8(CW)-100
Rated current (A)
15,20,30,40,50,60,75,100,125
Pole number
3 pole
Rated operating voltage (V)
Rated operating voltage (V)
PT-125
PT-250
RDM8 125-CW
RDM8 250-CW
PT MOULDED CASE CIRCUIT BREAKER
APPLICATION
PT Moulded case circuit breaker is suitable for circuit AC 50Hz/60Hz, rated voltage up toAC 660V,rated operating current to 630A. It features normal structure, reliable performance, complete accessories & high breaking capacity, used for power dis tribut ion and protecting t he circu it and electrical equipment against overload and short-circuit. It complies with standard of IEC947-2.
TRIPPING CHARACTERISTICS OF MCCB
Rated current of
release (A)
In 63
63 In 250
25 In 800
Thermodynamic release(ambient temp+40 )
1.05In (cold state)operative time (h)
1.30In (heat state)operative time (h)
Operational currentof magneticrelease(A)
1
2
2
1
2
2
10-50In 20%
10In 20%
5-10In 20%
RDM8-CW MOULDED CASE CIRCUIT BREAKER
RDM8-CW moulded case circuit breaker is available in three ranges, standard, high-breaking capacity. The performance of the RDM8-CW MCCB range is the result of ex tens ive design& development utilising AAD accredited test station. The current limiting action fo RDM8-CWMCCB provi des low va lues of let-through energy. Full information for this and time/currentcharacteristic curves are both available on request to provide more information.
MOULDED CASE CIRCUIT BREAKER
660V 380V, 660VRDM8(CW)-250 125,150,175,200,225,250 3 pole 660V 380V, 660V
TRIPPING CHARACTERISTICS OF MCCB
Rated current of
release (A)
In 63
63 In 250
25 In 800
Thermodynamic release(ambient temp+40 )
1.05In (cold state)operative time (h)
1.30In (heat state)operative time (h)
Operational currentof magneticrelease(A)
1
2
2
1
2
2
10-50In 20%
10In 20%
5-10In 20%
RDM8 125-CW
RDM8 125-CW
A C-05
-
TypePole
Number(P)
Rated current(A)Rated
current offrame(A)
Rated ultimatebreaking capacity
(KA)
RDM8 30-CSRDM8 50-CSRDM8 60-CSRDM8 100-CSRDM8 250-CSRDM8 400-CSRDM8 630-CSRDM8 800-CSRDM8 1250-CS
32,33
2,333333
3,5,10,15,20,3010,15,20,30,40,50
6060,70,100
125,150,175,200,225,250250,300,350,400
500,600,630600,700,800
800,1000,1200,1250
305060
100250400630800
1250
1.55/105/10
18/2518/3525/50
353585
RDM8-CS MOULDED CASE CIRCUIT BREAKER
APPLICATION
RDM8-CS series Moulded Case Circuit Breaker is a kind of economic breaker, has the features as following, such as steady and reliable property, reasonable structure, beautiful style, small volume,etc. This breaker applies to the circuit with AC 50/60 Hz, r ated insulation voltage 660V, max.rated current 1250A as on-off operation, and take effect, it also can be used as unfrequent conversion of line and unfrequency.
SPECIFICATION
RDM8-SS MOULDED CASE CIRCUIT BREAKERAPPLICATION
SPECIFICATION
RDM8-SS series Moulded Case Circuit Breaker is a kind of economic breaker, has the features asfollowing, such as steady and reliable property, reasonable structure, beautiful style, small volume,etc. This breaker applies to the circuit with AC50/60Hz, rated insulation voltoge 660V, max .ratedcurrent 1250A as on-off operation, and take effect, it also can be used as unfrequent conversion ofline and unfrequency.
Type Polenumber
Rated current(A)
Breaking capacity(KA)
AC(P1/P2)
RDM8 30-SS
RDM8 50-SSRDM8 60-SS
RDM8 100-SS
RDM8 250-SS
RDM8 400-SS
RDM8 630-SS
RDM8 800-SS
23333434343434
3,5,10,15,20,30
10,20,30,40,5010,20,30,40,50,60
60,75,100
125,150,175,200,225,255
250,300,350,400
500,600,630
600,700,800
240 380 415 500 600 660
5/5 5/2.5 2.5/1.5 2.5/1.0
5/105/10
10/7.510/7.5
7.5/57.5/5
7.5/57.5/5
2.5/1.52.5/1.5
- -
--
50/42
50/42
85/60
85/60
85/60
30/20
30/22
50/35
50/35
50/35
7.5/8
25/15
25/20
50/30
50/30
15/10
18/15
35/25
35/25
35/25
10/5
15/10
25/18
25/18
25/18
5/2.5
5/2.5
15/10
15/10
15/10
RDM8 30-CS 3P
RDM8 100-CS 3P
RDM8 50-SS 3P
RDM8 250-SS 3P
MOULDED CASE CIRCUIT BREAKER
RDM8 30-CS
RDM8 100-CS
RDM8 50-SS
RDM8 250-SS
A C-06
-
Type Pole Rated current(A)Breakingcapacity
(KA)Rated voltage(V)
RDM7 32
RDM7 33
RDM7 52
RDM7 53
RDM7 62
RDM7 63
RDM7 102
RDM7 103
RDM7 202
RDM7 203
RDM7 403
2
3
2
3
2
3
2
3
2
3
3
3,5,10,15,20,30
3,5,10,15,20,30
15,20,30,40,50
15,20,30,40,50
60
60
60,75,100
60,75,100
125,150,175,200,225
125,150,175,200,225
250,300,350,400
1.5
1.5
2.5
2.5
2.5
2.5
7.5
7.5
10
10
18
415
415
600
600
600
600
600
600
600
600
600
Type Pole Rated current(A)Breakingcapacity
(KA)Rated voltage(V)
RDM7 32
RDM7 33
RDM7 52
RDM7 53
RDM7 62
RDM7 63
RDM7 103
RDM7 202
RDM7 203
RDM7 403
2
3
2
3
2
3
3
2
3
3
3,5,10,15,20,30
3,5,10,15,20,30
15,20,30,40,50
15,20,30,40,50
60
60
15,20,30,40,50,60,75,100
125,150,175,200,225
125,150,175,200,225
250,300,350,400
1.5
1.5
5
5
5
5
15
18
18
22
660
660
660
660
660
660
660
660
660
660
RDM7(EA\SA) MOULDED CASE CIRCUIT BREAKER
APPLICATION
The circuit breaker is suitable for industrial or commercial power and lighting circuit. Its ratedworking voltage is from 240V to 415V(AC 50Hz). It can be used to protect the ci rcuit that overload or short circuit may take place and also for protecting the circuit which is not frequent in makingbreak operation under normal conditions.
SPECIFICATION
RDM7 52B(SA52B)
RDM7 33B(SA33B)
RDM7 103B(EA103B)
MOULDED CASE CIRCUIT BREAKER
RDM7 103B
RDM7 33B
RDM7 52B
A C-07
-
PABS-D MOULDED CASE CIRCUIT BREAKER
APPLICATION
PABS-D series moulded case circuit breaker is suitable for industrial or commercial power andlighting with AC 50/60Hz, rated working volt age up to AC600V/DC 250V, rate d cu rrent up to 1200A. It s a kind of economical breakers with the ch aract ers of s table an d r eli abl e f unctio n,beautiful appearance, small size and line and infrequent starting motor. It can also be a ttachedto ins tall the accessor ies which have protection function for avoiding loss-voltage, under-vo ltage.The prod uct can inst all conn ection line with front board and back board, it also can be equipped hand-operating appar atus or mo tor-op erating apparatus to control in a remote distance.
SPECIFICATION
Number of poles
Max rated servicevoltage Ui (V)
Dim
ensionsandm
ountingdetails aaa c
MOULDED CASE CIRCUIT BREAKER
PABS-103b
PABS-103b
PABS-203b
PABS-203b
PABS-403b
PABS-403b
A C-08
10,15,20,30,40,50,60,75,100
500V 600V
440V 480V
380V
220V 240V
3
600
250
90
155
56
82
132
30
10
14
25
50
10
14
14
25
50
20
14
-
-
-
-
-
-
-
-
Rated current in (A) 40 reference ambient temperature
3
600
250
105
165
56
84
126
30
10
14
25
50
10
14
25
25
50
20
14
3
600
250
140
257
95
145
215
44
22
25
35
50
22
25
35
35
50
20
14
125,150,175,200,225
250,300,350,400
Dim
ensionsandm
ountingdetails
GB14048-2 AC (No symmetry value/symmetry value)
IEC60947-2 Icu AC
DC
Connection way
Alarming switch (AL)Auxiliary switch (AUX)
Voltage release mounting (SHT)
Low voltage release mounting (UVT)Accessory lead wire terminal platform (LT)
Outer operate handle
Terminal isolation cover
Automatic tripping device
Trip button
AC
DC
a
b
c
ca
bb
aa
500V
440V
415V
380V
240V
250V
125V
Shoppingfitting
Press terminal
-
- Thermal electro-magnetism type
Have
b bb
ca
-
MCCB Description Standard rangeCurrent rating(A)
Standard range
16A20A32A40A50A63A80A
100A125A160A200A
1 poleList number
3 polesList number
PME161PME201PME321PME401PME501PME630PME801
PME1001PME1251PME1604
-
PME163PME203PME323PME403PME503PME633PME803
PME1003PME1253PME1603PME2003
Impulse withstand V.Utilisation categoryAdjustment thermal
Adjustment magneticTerminal capacity(Max)
8KVA
FixedFixed
120mm2
8KVA
FixedFixed
120mm2
Breaking capacity IEC60947 2/BS EN60947-2(AC 50/60Hz)
690V AC
480V AC
400V AC/440V AC
380V AC
220V AC/240V AC
250V DC
Icu (KA)Ics (KA)Icu (KA)Ics (KA)Icu (KA)Ics (KA)Icu (KA)Ics (KA)Icu (KA)Ics (KA)Icu (KA)Ics (KA)
--------
2519--
121220202525303040403719
PME-125 3P
PME-250 3P
PME MOULDED CASE CIRCUIT BREAKER
SPECIFICATION
PME moulded case circuit breaker is highly specified. Positive contact indication is standard,with three positions ON OFF and centre TRIPPED preventing the MCCB contactsfrom being held closed in the event of over current.
PME moulded case circuit breaker 3 & 1 pole units have a trip to test button provided a s st andard.All main contacts are of quality. Silve alloy construction for durability. Comply ing with IEC60947-2is covered by type test and marine approval certification.1. Moulded case circuit breakers 16 to 200A.2. Available in three ranges: standard, standard adjustable, Hi-break adjustable.3. Complies with IEC60947-2.4. Current limiting action provides low values of lot-through energy.
PME STANDARD RANGE
MOULDED CASE CIRCUIT BREAKER
A C-09
-
PAA MOULDED CASE CIRCUIT BREAKER
DESCRIPTION
PAA MCCB is Available in two frame sizes from 25 to 800 A. Loadline series of mouldedcase circuit breakers provide overload and short-circuit protection for the full range o f transf-orme r sizes encountered in normal service. The over load and i nstantaneo us trippin g elements,adjustable over a wide band, make these MCCBs ideal for many distribution applications. PAA MCCBs are available in single pole, three poles, three pol es with sw itched neu tral and switch-disconnector versions. Loadline triple poles PAA Frame circuit breaker and switch-disconnectorare physically interchangeable with PAA breakers for Motor Duty requirments. PAA Frame have front adjustable overload and fixed instantaneous tripping elements.
SPECIFICATION
TRIPPING ELEMENT
Insulation voltage(Ui)-660V acOperating voltage(Ue)-415 acRated frequency-~50/60HzReference Calibration-40 (50 on request)
Overload front adjustable 0.7-1.0 times rated currentInstantaneous-non-adjustable
PAA 25-63A=400A PAA 80-125A=800A PAA 160-250A=1600A
Description
25
32
40
50
63
80
100
125
160
200
225
250
315
400
500
630
800
In/A Lowest Setting Current amps
17.5
22.5
28
35
44
56
70
88
112
140
157.5
175
221
280
350
441
560
PAA-100
single pole MCCB
triple poles MCCB
PAA-250
PAA Frame
PAA-400
PAA-630
PAA-800
PAA 100 1P
PAA 250 3P
PAA 400 3P
MOULDED CASE CIRCUIT BREAKER
A C-10
-
PDPX-125N 3P
PDPX-250N 3P
PDPX MOULDED CASE CIRCUIT BREAKER
Pole numberRated current In(A)
Type
The electrical characteristic satisfiesEn60947 - 2Rated working voltageUe(50-60Hz)
Rated working voltage Ue=(V)Rated insulation voltage Ui~(V)Rated impulse voltage Uimp(KV)Usage groupMoulded case switch typeLimited breaking capacity(KA) 230/240V~
400/415V~440V~480/500V~600V~690V~250V
Used breaking capacity lcos(%Icu)Short-circuit closed capacity(400V~)Short-time withstand current Icw(KA)Life (open,close for a time) mechanical
ElectricalInsulation capacity
Protection groupHot-magnetic tripElectronic tripTake to connect the ground to breakDown to probe into the function s theHigh choice electronic-tripResidual currentprotected modules installation
Bottom
On the sideinstallation
Outer accessoriesControl from a distanceFix typeInsert typeDrawer typeScrew hand handlePower conversion systemDimension and weightDimension (L W H) (mm)
Weight(kg)
3 pole4 pole3 pole4 pole
PDPX 125 PDPX 250
PDPX-E PDPX PDPX PDPX PDPXPDPX-E3-4
16-1253-4
25-250
500
250500
6A
690
250690
8A
E2216108--
1610032
35251812--
2550
52.5
50362014--
3050
75.6
60363025201636
10075.6
L170100704025204050
220
H10070604025204075
154
7000
1000
7000
1000
75.6 120 74101 120 74
11.2
105 200 105140 200 105
2.53.7
MOULDED CASE CIRCUIT BREAKER
A C-11
DESCRIPTION
-
PVL-160X 3P
PVL-250X 3P
PVL MOULDED CASE CIRCUIT BREAKER
DESCRIPTION
TypeRated
currentIn(A)
Setting current ofinverse-time
delayed overloadrelease L I (A)R
Operating current ofinstantaneous short-circuit release I Ii
(A)
Standard switchingcapacity N 40/45/50kA
at 380/415V AC
PVL 160X
PVL250
20
32
40
50
63
80
100
125
160
200
255
16-20
25-32
32-40
40-50
50-63
63-80
80-100
100-125
125-160
160-200
200-250
300
300
600
600
600
1000
1000
1000
1600
1000-2000
200-2500
PVL1702-1DD33-...
PVL1703-1DD33-...
PVL1704-1DD33-...
PVL1705-1DD33-...
PVL1706-1DD33-...
PVL1708-1DD33-...
PVL1710-1DD36-...
PVL1712-1DD36-...
PVL1716-1DD36-...
PVL3720-1DD36-...
PVL3725-1DD36-...
Type
PVL 160X
High switching capacity H 70 kA
at 380/415V AC
Very high switching capacity L
100kA at 380/415V AC
PVL 250
PVL1702-2DD36-...
PVL1703-2DD36-...
PVL1704-2DD36-...
PVL1705-2DD36-...
PVL1706-2DD33-...
PVL1708-2DD36-...
PVL1710-2DD36-...
PVL1712-2DD36-...
PVL1716-2DD36-...
PVL3720-2DD36-...
PVL3725-2DD36-...
PVL3720-3DC36-...
PVL3725-3DC36-...
XXX
X
Z
Y Y
PVL 160 circuit-breaker
419
2411
106.590.58781.5
120.5 63.5
5831
.5
4-(250)d2.5-(160)
88.5
15.5 Y Y
35 35 35
PVL 160 and PVL 250circuit-breakers mounting detailPVL 250 circuit-breaker
17.56 5.2
75.5
140 174.5
115.5 Y
88.5
1224.5
104.5139.5
52.5
1632
1632
NSK
-884
0
NSK
-884
1
8
35 35 35 17.56 8.417.5
35(3P)
7 13 5.5
75.5
174.5
185.514
913
11.5
24.5104.5
139.552.5
18(8) 70(4P)
19.5
6513
1.5
2 5.2(3P)4 5.2(4P)
MOULDED CASE CIRCUIT BREAKER
A C-12
-
A C-13
105 86
152
100
DESCRIPTION
PHFD MOULDED CASE CIRCUIT BREAKER
PHFD moulded case circuit breakers are the choice of designer for coordinate protection of all types of low voltage power distribution systems.
Description
Single pole MCCB
Triple poles MCCB
In/ARated isolating
voltage(V)
Rated capacity
(KA)
15
20
25
30
35
40
50
70
90
100
125
150
15
20
25
30
35
40
50
70
90
100
125
150
175
200
225
250
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
PHFD-250N 3P
PHFD-125N 3P
MOULDED CASE CIRCUIT BREAKER
-
A C-14
SPECIFICATION
PHB MOULDED CASE CIRCUIT BREAKER
Manufacture stardand:IEC60947-2Fixing type thermal tripFixing type magnetic trip
MAX. RATED SHORT-CIRCUIT BREAKING CAPACITY
PHB126HPHB226HPHB226NPHB226E
Hull
65kA35kA40kA
100kA
220/240VAC
25kA25kA40kA70kA
380/415VAC 660/690VAC
--
12kA14kA
250VDC*
10kA-
10kA20kA
Description Rated current(A)
MCCBMCCBMCCBMCCBMCCBMCCBMCCBMCCBMCCB
PHB226H-25kAMCCBMCCBMCCBMCCBMCCBMCCBMCCB
PHB126H-25kA1620253240506380
100
6380
100125160200225
PHB226N-40kA
Description
MCCBMCCBMCCBMCCBMCCBMCCBMCCB
PHB226E-70kAMCCBMCCBMCCBMCCBMCCBMCCBMCCB
6380
100125160200225
6380
100125160200225
Rated current(A)
ACCESSORY AND AUXILIARY EQUIPMENT
Revolve the hand handle the organizationLocks-AA auxiliary switch,2NO+2NC-UV Owe-voltage trip,415V~-SR Cent trip,240V~-UV2 Owe-voltage trip,240V~
80
72
80
126
101.
7
104.785.8
81
226
PHB-126 3P
PHB-226 3P
MOULDED CASE CIRCUIT BREAKER
PHB-126
PHB-226
-
A C-15
MOULDED CASE CIRCUIT BREAKER
PTCD\PEB\PQD Series moulded case c ircuit breaker is one of our new type productsdeveloped and manufactured by adopting international adv anced technology. It is supplied withrated insulating voltage 660V and used for circuit of A.C.50Hz, rated operati ng voltage AC 380V.(Or below), rated operati ng current up to 22 5A for infre que nt cha ngi ng ove r and starting of the motors. Equipped with the protection devices for over-cur rent, shor t-circ uit a nd under-voltage, the products are capable of preventing damage of circuits and supply units.
DIMENSIONS OF OUTLINE AND INSTALLATION (PQD)
SPECIFICATION
Model Pole Rated Current (A) Rated Insulation voltageRated operating
voltage
PTCD
PEB
PQD
3 30,40,50,60,70,100
125,150,175,200,225
3
3
30,40,50,60,70,100 600V240V380V660V
PTCD-100 3P
PEB-100 3P
PQD-250 3P
243
183
6169
35
8
487
321 32
27 14
223 32
1116 1 8
3
11 3219 32
123 64
3 81 4
34
2532
5 329 16 2
3
1
1116
138
1116
138
9 323
4 81
2 141 1 114
2332 7 32
19 32
13
4
1 32
122
1516
2 582 16143 14
7
116
14 1
5 32
132
MOULDED CASE CIRCUIT BREAKER
PTCD-100
DESCRIPTION
-
Type
RDW1-2000
RDW1-32004000
RDW1-63004000/5000
RDW1-6300
Pole
3P
4P
3P
3P
4P
3P
4P
3P
L1
375
470
435
550
550
813
928
928
L2
335
430
395
510
510
773
888
888
L3
292
292
352
352
352
352
352
352
L4
356
360
325
440
440
703
818
818
L5
247
247
307
307
307
307
307
307
W1
421
494
W2
467
540
b
139
212
In A
10
15
20
30
20
30
RDW1-3200 could increase to 4000A,its installation dimension is same with RDW1-3200,4P
RDW1-2000 cable dimensionfor with drawable type
RDW1-3200 cable dimensionfor with drawable type
RDW1-3200 In=4000A RDW1-6300, In=4000A, 5000Acable dimension for with drawable type
RDW1-6300, In=6300Acable dimension for with drawable type
RDW1-2000
RDW1-3200
RDW1 AIR CASE CIRCUIT BREAKER
SCOPE OF APPLICATION
400~630
800~1600
2000~2500
3200~4000
4000
5000~6300
a
AIR CASE CIRCUIT BREAKER
A C-16
-
RDW1 AIR CASE CIRCUIT BREAKER
50kA/400V40kA/690V
50kA/400V40kA/690V
100kA/400V80kA/690V
80kA/400V60kA/690V
80kA/400V65kA/690V
100kA/400V80kA/690V
80kA/400V65kA/690V
80kA/400V65kA/690V
120kA/400V80kA/690V
100kA/400V70kA/690V
100kA/400V70kA/690V
It can be used as controlling and protecting Electric Power Distribution line & Net. It is normally installed in Low-Volt age Sw itc hge ar as main Switch for total protection. The technical performance of our goods have reached advanced level of same item in the world.
MAIN TECHNICAL PARAMETER
Frame classing rated current
Rated insulation voltage
Rated voltage
Rated current
Rated ultimate short-circuit breaking capacity(lcu)
Rated service short-circuit breaking capacity(lcs)
Rated withshand current for short-time(lcw)
Number of poles
Arcing distance
2000A 3200A 4000A 6300A
690V
400V
630A,800A,1000A,1250A,1600A,2000A,2500A,3200A,4000A
80kA/400V50kA/690V
3P, 4P
0
Fault deviate indication/reposit pbutton
Shut button
Manua/Power store handle
Dispart button
Power store & releaseindication
Shut & Dispart indication
Panel
In-Out devicePosition indication
Shakable handle &its depositary
Two times loop terminal connector(moving)
Two times loop terminal connector(moving)
Under-Uoltage reloaseDraw-out seatingShunt releaseAwciliary contactClose electromagnetIntelligent controller
Electric operation frameworkOperation framework
AC Rated Current:630A-3200ABreaking Capacity:80kA-100KA(virtual value)Rated working voltage: AC960VType:Draw-Out type and Fixed Mounted typeStandards: IEC60947-2, GB14048.2
AIR CASE CIRCUIT BREAKER
A C-17