PENTAX Medical Maximum support from detection to diagnosis€¦ · PENTAX Medical Maximum support...
Transcript of PENTAX Medical Maximum support from detection to diagnosis€¦ · PENTAX Medical Maximum support...
HD+ and i-scanEBUS and EUS
PENTAX Medical Maximum support from detection to diagnosisSuperior imaging and treatment modalities.
EUS HD+ image i-scan EBUS
EG-3270UK
Forward oblique [50°]
120
5-100
130/130
10.8
12
11.5
2.8
1.250
120
5-10 switchable
Longitudinal
Convex
The outstanding image quality of the EB-1970UK offers an uncompromising foundation for detection and staging of lymph nodes and tumours in the lung.
Endobronchial ultrasound and real-time EBUS-TBNA contribute to a more reliable diagnosis - becoming a standard for opti-mal patient care.
Elastography is an imaging modality that evaluates the relative stiffness of tissue within the body, by its response to com-pression and may help in more precise staging and diagnosis.
The EG-3270UK combines the feasibility of Fine Needle Aspiration (FNA) with excellent ultrasound image quality.
This unique combination sets a new standard in endoscopic ultrasound for everyday practice; easy to use and applicable to a wide range of procedures.
The combination of EBUS-TBNA and EUS-FNA may lead to an increase of the diagnostic accuracy compared to each technique alone.
Unique High-Defi nition (HD+) images and excellent illumination support fast orientation and detection.
It signifi cantly improves the visibility and evaluation of anatomical details of the bronchial mucosa.
HD+ combined with i-scan technology offers enhancement of lesion margins and vessels architecture supporting easier demarcation of suspicious areas and characterisation of mucosal abnor-malities.
Signifi cantly improves the endoscopic diagnosis by supporting the identifi cation of areas to be treated.
Endoscopic Ultrasound
Type
Direction of viewing fi eld
Field of view [°]
Dept of fi eld [mm]
Tip defl ection ud/down [°]
Insertion tube [ø mm]
Distal end [ø mm]
Distal end diameter US probe [ø mm]
Instrument channel [ø mm]
Working length [mm]
Scanning angle [°]
Acoustic Frequency [MHz]
Scanning direction
Scanning system
Interventional Bronchoscopes
Type
Insertion tube [mm]
Distal end [mm]
Instrument channel [mm]
Working lenght [mm]
Field of view [°]
Tip defl ection up/down [°]
Depth of fi eld [mm]
Remarks
EB-1990i* EB-1575K EB-1975K
6.4 5.2 6.4
6.6 5.5 6.3
1.2 2.0 2.8
600 600 600
120 120 120
180/130 210/130 180/130
3-50 3-50 3-50
STERRAD® compatible (applies to all three products)
*HD+ Image
EB-1970UK
Forward oblique [45°]
100
2-50
120/90
6.3
7.4
6,5 x 7.0
2.0
600
75
5-10 switchable
Longitudinal
Convex
In the interest of technical progress, specifications may change without notice.
LCM
/01/
09/1
4/32
0096
/02
PENTAX Europe GmbHRepresentative office in MoscowSadovnicheskaya str, 82, build 2, entrance 6Regus, Business center „Aurora“Office 2012, 2013Moscow, 115035Russian FederationTel.: +7 495 / 792 52 00Fax: +7 495 / 792 35 66
PENTAX TurkeyVeko Giz Plaza, Meydan SokakNo:3/43 343396Maslak – IstanbulTurkeyTel.: +90 212 / 705 05 26Fax: +90 212 / 705 05 00
HOYA CorporationPENTAX Life Care Division1-1-110, TsutsujigaokaAkishima-shi196-0012 TokyoJapanTel.: +81 3 / 39 60 51 55Fax: +81 3 / 53 92 67 24
PENTAX Europe GmbHJulius-Vosseler-Straße 10422527 HamburgGermanyTel.: +49 40 / 5 61 92 - 0Fax: +49 40 / 5 60 42 13E-mail: [email protected]
PENTAX U.K. LimitedPENTAx HouseHeron Drive, LangleySlough SL3 8PNUnited KingdomTel.: +44 17 53 / 79 27 33Fax: +44 17 53 / 79 27 94E-mail: [email protected]
PENTAX France Life Care S.A.S.112 quai de BezonsB.P. 20495106 ARGENTEUIL CEDExFranceTel.: +33 1 / 30 25 94 78 Fax: +33 1 / 30 25 74 45E-mail: [email protected]
PENTAX Nederland B.V.Amsterdamseweg 291420 CA UithoornNetherlandsTel.: +31 88 / 5 30 30 30Fax: +31 88 / 5 30 30 40E-mail: [email protected]
PENTAX Italia S.r.l.Via Dione Cassio, 1520138 MilanoItalyTel.: +39 / 02 50 99 58 1Fax: +39 / 02 50 99 58 60E-mail: [email protected]
SIMMEDICA – Sistemas Integralesde Medicina, S.A.Avenida del Sistema Solar 2528830 San Fernando de Henares · MadridSpainTel.: +34 91 / 301 62 40Fax: +34 91 / 751 31 15E-mail: [email protected]