The Effects of VFDs on Centrifugal Wastewater PumpsTechnical Series 2014
PENTAIR 2
PENTAIR
Course Objectives
•Understanding of AC Induction Motors
•VFDs- Are they Magic?
•Variable Speed and Wastewater Pumping
3
PENTAIR 4
AC Induction MotorsTheory & Design
PENTAIR 4
PENTAIR 5
Basic Motor Vocabulary• Poles- Number of magnetic poles (or
coils) 180-degrees apart in the stator
• Service Factor- Amount of overload motor can handle typically expressed in amps
• Synchronous Speed- Speed at which magnetic field in the motor is rotating; also the “no-load” speed of the motor. Expressed in RPM’s
• Slip- Difference between Synchronous Speed (Theoretical) and Full Loaded Speed (Actual). Expressed in a percentage
PENTAIR
Motors
•Rotational Speed of AC induction motors depend on two things:Poles in the statorFrequency of power (Hz)
•Poles in the motor are a constant
• Speed varies directly with Frequency
6
PENTAIR 7
Motors
• In the US power is 60hz or 60 cycles per second
• This is just the standard in the early days the cycles varied wildly. It was Nikola Tesla the inventor of the AC induction motor who standardized on 60Hz
• Motor speed is determined by number or North & South Poles in the motor (+/-)
Simple DC Motor
PENTAIR 8
• Motor speed is determined by number or North & South Coils in the motor (+/-)
• These always occur in twos 2-pole/4-pole/6-pole
• Formula for figuring speed in RPM120 x Frequency / Number of poles 120 is constant 120 x 60 = 7200 7200/ 4 = 1800RPM
Two & Four Pole Three Phase Motors
Poles & Speed
PENTAIR 9
Motors
•What is my Speed?– Difference between
Synchronous Speed and Full Load Speed is described as Slip– Slip is typically between 3% &
5%– So;
• 1800RPM * 0.97 = 1746RPM (1750RPM)• 1800RPM *0.95 = 1710RPM
(1700RPM)
Synchronous
RPM
PENTAIR 10
VFDs Why we use themReview of VFD principal
PENTAIR 10
PENTAIR
VFDs- How it works
•Converts AC to DC to AC
•Allows for modulation of the Frequency
•Remember frequency controls speed in AC motors
•Power is not true Sine wave but “Block-wave”
11
PENTAIR
VFDs- How it works•The block nature of the AC
power of a VFD creates harmonics in the pump causing vibration
• Lower Pulse (slower) drives have higher harmonic distortions
•Higher Pulse (faster) drives have less harmonic distortion
12
PENTAIR
High Pulse Drives •18-Pulse drives allow for smoother operation of rotating
equipment as by using insulated gate transistors to synthesize a cleaner sine wave power curve
13
PENTAIR
High Pulse Drives
•18-Pulse and higher drives have drawbacks
•Voltage unbalance/pulses cause induced AC voltage on the motor shaft
• Leads to a continuous discharge of voltage most often across the bearing
14
PENTAIR
Why Use a VFD • Pumps are often designed for
worst case scenario. (I&I or peak demand)
• These extremes do not happen often
• However pumps slide up and down curve depending on demand and system
• The ability of a VFD to modulate speed allows for pump to run at BEP across operating range
15
PENTAIR 16
Variable Speed and Wastewater PumpingBringing it all together
PENTAIR 16
PENTAIR
Using a VFD with a submersible pump
•Pump COS 100GPM at 100’TDH 3500RPM 4.04HP (at design) 5.25Impeller Diameter Change System Pressure to 56’TDH
• What Happens?
PENTAIR
Pump & System Head Curve • System head drops from 100’ to 56’ • At 3500RPM efficiency drops below 40% suction cavitation is a
problem •With VFD at 2625RPM efficiency is constant at 62%
18
PENTAIR
Wastewater Pumps & VFDs
19
PENTAIR PRESENTATION TITLE
Cost Savings on a VFD
20
• At Constant Speed- System would use $45,485.00.• At Variable Speed- System would use $19,742.00.• Variable Speed nets a $23,433.00 energy savings.
PENTAIR
Wastewater Pumps & VFDs
• The ability to maintain efficiency is useful for wastewater pumping where constant flow & pressure is not a concern
• Eliminates the need for a shaver pump
• Keeps pump from either suction or recirculation cavitation
21
PENTAIR
Wastewater Pumps & VFDs
• VFDs give the operator the ability to run the pump/motor in reverse. This can be beneficial to clear a blockage in the volute
• Eliminates throttle valves in the system
• Avoids water hammer and pressure spikes by controlling speed and ramp up & ramp down
22
PENTAIR
Wastewater Pumps & VFDs
•Potential Pump IssuesService factor for many motors
is 1.15 for constant speed but drops to 1.0 on VFD
Decrease bearing life unless shaft currents are mitigated (Insulated bearing or SGR)
First Criticals can move around
23
PENTAIR
Wastewater Pumps & VFDs
•Pipeline Issues- depending on how drive is program you can see velocity issues
For example our test pump at 100GPM and 3500RPM has plenty of flow to achieve 2FPS in a 4” force main
However at 2625RPM we only produce 75GPM when 80GPM is needed for 2FPS
24
PENTAIR PRESENTATION TITLE
Wastewater Pumps & VFDs
•Other FactorsMore complex controls usually
utilizing a transducer
Higher noise in motor due to chatter in the motor windings produced by the block wave form
Don’t be tempted to turn pump so slow it can not move solids
25
PENTAIR 26
The Take Away Technical Series 2014
PENTAIR 26
PENTAIR
The Take Away•VFDs when properly applied
to collection systems can yield substantial cost savings and longer service life
• Look for equipment that is designed for use with VFDs to ensure maximum benefit
•Weigh all options as well as Total Cost of Ownership
27