PAVSYS PAVSYS ™ PAVSYS PAVSYS MODULAR ENGINEERED SUSTAINABLE HABITATS.
-
Upload
nicholas-cross -
Category
Documents
-
view
220 -
download
1
Transcript of PAVSYS PAVSYS ™ PAVSYS PAVSYS MODULAR ENGINEERED SUSTAINABLE HABITATS.
P A V S Y S P A V S Y S ™ P A V S Y S P A V S Y S
PAVILION SYSTEMS AUSTRALIA
M O D U L A R E N G I N E E R E D S U S T A I N A B L E H A B I T A T S
PAVSYS EXT12CB24
P A V S Y S P A V S Y S ™ P A V S Y S P A V S Y S
PAVSYS
450 CORE
PAVSYS
450 CORE
Slide each full length core section into the grooves cut in the flat panel surface......
Place the wall panel face down on a flat surface.....
PAVSYS EXT12CB24
P A V S Y S P A V S Y S ™ P A V S Y S P A V S Y S
Form window opening by sliding each core section (in sequence) into the grooves cut in the flat panel surface......
PAVSYS
450 CORE
250.
15 C
ORE
600.15 CORE
250.15 CORE
600.15 CORE
PAVSYS
450 CORE
Place the next wall panel face down on a flat surface.....
PAVSYS PAVSYS
500 CORE 500 CORE
PAVSYS EXT12CB24
P A V S Y S P A V S Y S ™ P A V S Y S P A V S Y S
Place each panel upright on the edge of the concrete floor slab......
PAVSYS PAVSYS
500 CORE 500 CORE
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
600.15 CORE
600.15 CORE
250.
15
CORE
250.
15
CORE
PAVSYS EXT12CB24
P A V S Y S P A V S Y S ™ P A V S Y S P A V S Y S
Place the adjoining panel with the window framing cores already fitted......
PAVSYS PAVSYS
500 CORE 500 CORE
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
600.15 CORE
600.15 CORE
250.
15
CORE
250.
15
CORE
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
PAVSYS EXT12CB24
P A V S Y S P A V S Y S ™ P A V S Y S P A V S Y S
Continue to place each panel until you complete one section......
PAVSYS PAVSYS
500 CORE 500 CORE
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
600.15 CORE
600.15 CORE
250.
15
CORE
250.
15
CORE
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
PAVSYS EXT12CB24
P A V S Y S P A V S Y S ™ P A V S Y S P A V S Y S
Insert the steel locking plates to span adjoining panels and fit under the window openings......
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
600.15 CORE
600.15 CORE
250.
15
CORE
250.
15
CORE
P A V S Y S P A V S Y S ™ P A V S Y S P A V S Y S
Mount the steel rebar in the gaps between the cores and tie the overlaps......
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
600.15 CORE
600.15 CORE
250.
15
CORE
250.
15
CORE
P A V S Y S P A V S Y S ™ P A V S Y S P A V S Y S
Complete all the wall sections, then spray shotcrete over the rebar to create interlocking columns and beams......
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
600.15 CORE
600.15 CORE
250.
15
CORE
250.
15
CORE
P A V S Y S P A V S Y S ™ P A V S Y S P A V S Y S
EITHER: Continue to apply shotcrete to form an exterior coating finishing flush with the cores that frame the openings......
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
600.15 CORE
600.15 CORE
250.
15
CORE
250.
15
CORE
P A V S Y S P A V S Y S ™ P A V S Y S P A V S Y S
After the shotcrete has cured, remove the full depth cores and install the window and door frames......
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
600.15 CORE
600.15 CORE
250.
15
CORE
250.
15
CORE
P A V S Y S P A V S Y S ™ P A V S Y S P A V S Y S
OR: Alternatively fasten the horizontal sheeting to the mounting strips fixed to the concrete columns......
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
PAVSYS EXT12CB24
PAVSYS PAVSYS
500 CORE 500 CORE
600.15 CORE
600.15 CORE
250.
15
CORE
250.
15
CORE
P A V S Y S P A V S Y S ™ P A V S Y S P A V S Y S
Remove the full depth cores framing the openings and install the window and door frames......
P A V S Y S P A V S Y S ™ P A V S Y S P A V S Y S
PAVILION SYSTEMS AUSTRALIA
NOTE: To ensure correct core depths, exterior cladding options are selected at time of order......
www.pavilionsystems.com.au email: [email protected] Telephone: 1-800-PAVSYS (1-800-728-797)
© COPYRIGHT – PAVILION SYSTEMS AUSTRALIA - 2013