Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800...

83
Pressurecare Patient Positioning in Operating Room

Transcript of Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800...

Page 1: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Pressurecare

Patient Positioning in Operating Room

Page 2: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Agenda

Recap on Product Range

4 Main Positions & Associated Risks with backup Info on

Pressure Mapping

Background info on Pressure Ulcers and Nerve Injuries

Implications and Considerations for Clinical Practice

Reasons for Pressurecare Range

Page 3: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Some Interesting Findings…

• Surgical patients account for 20% to 30% of all pressure injuries.

• Pressure Sores are ‘not only life altering but life threatening’!

• Usually presents as a burn or bruise with rapid progression within 1–3

days post surgery.

• Pressure injuries are, in most cases, preventable!

• Patient Positioning: Education is key. (www.surgicalproductsmag.com. 2010. Claire Williams

Tager)

Page 4: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Preventative Measures…

Positioning a patient properly on the operating table is critical

Page 5: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Why Silicone

• Medical Grade Silicone

• Silicone is a ViscoElastic material

• Redistributes weight better than PU gels (ACTION)

• Scientifically Developed & Proven through R&D

• Soft as skin and underlying fatty tissue

• Redistributes pressure very effectively

• Reduces Impact of Shear and Friction

Page 6: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Additional Benefits of Silicone

• Distributes Weight Effectively

• Hypoallergenic / Latex Free

• X-ray Translucent / MRI Compatible

• Easy to Clean / Won’t Support Bacterial Growth

• Reusable & Very Durable

• Most Extensive Range

• Dampens Impact

• Thermal Stability: Cool or Heat

• Fire Rated as Self Extinguishing

• Non Conductive

• Oasis + is autoclavable

Page 7: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Features & Benefits

Original gel solution,

100% silicone

Very extensive range of

products

Resembles human skin Pressure mapping

19.7mmHg

Effectively redistributes

pressure

Interface pressure

should be less than 32

mmHg

Page 8: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Features & Benefits

Pre-Contoured.

Combination of Gel and

Foam

Pressure mapping

results: 11.4mmHg

Enhanced redistribution

of pressure

Most extensive range of

products

50% lighter than Oasis

Range

Page 9: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Features & Benefits

Dual-layer silicone

protection with

anatomical design

Facilitates excellent

redistribution of pressure

20% lighter than Oasis

Range

Pressure mapping

8.64mmHg

Product range designed

for the Supine and

Lithotomy Position

Page 10: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Features & Benefits

Medical grade siloxane

elastomer

Easy to clean and fully

autoclavable

No outer film ensures

exceptional durability

Non-slip properties for

patient comfort and

support

Pressure mapping

10.28mmHg

Ergonomic design for

effective pressure relief

Oasis+ offers the ultimate

in pressure relief, and

positioning.

The products are fully

autoclavable, re-usable,

ergonomically designed,

with an anti-slip base. This

entirely unique range is a

revolution in Pressurecare

Page 11: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Pressure Mapping

• In Trulife we use FSA (Force Sensitive Applications).

• Strict protocol to ensure accurate representations of

body form and body mass are applied when using the

apparatus

Enables us to evaluate & design our pressurecare range

for optimal pressure relief

Page 12: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Pressure Injuries

Incidence Definition

Risk Assessment

Page 13: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Pressure Injuries

Page 14: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Pressure Ulcer – Definition

A pressure ulcer is an injury to skin as a result of

constant pressure due to impaired mobility

JAMA, 2006 – Vol 296, No 8. Pressure Ulcers

What is a Pressure Ulcer?

“ ”

Page 15: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Skin Cell

Page 16: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Stage 1:

Reddening

Stage 4:

Necrosis of

Muscle

Stage 2:

Epidermis Broken Stage 3:

Subcutaneous

Stages of Pressure Ulcers

Page 17: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Incidence

Sacral Ischial

49%

Other

Elbow/Head

30.5%

Hip – Greater

Trochanter

11%

Heels

9.5%

Page 18: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Risk Assessment: Example

Page 19: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Supine: Areas at Risk

Pressure Ulcer

Occipital Region

Elbow

Sacrum

Buttocks

Heels

Nerve Damage

Elbow: Ulnar Nerve

Arm: Brachial Plexus

Lumbar: Sciatic Nerve

Page 20: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Supine: Azure

Lumbar

Sciatic

Nerve

Elbow

Ulnar

Nerve

Heels

AZ400 AZ300 AZ201

Page 21: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Head in Supine or Lithotomy

EL011

EL012

OA012

OA011

OA010

AZ100

Head Rings

• Aim: to prevent

occipital Pressure

Ulcers

• This should in turn

prevent Alopecia

• NB: Important to

use right size

head ring!

Page 22: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Alternative

EL151

EL030

Also

Available:

EL152

Adolescent

Head Rest

For Eye Surgery Resuscitation Trolleys – Airway

Management

Page 23: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Head & Neck

OP151

Page 24: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Head & Neck

OP015

Page 25: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Table Pads

OA030 EL031

Page 26: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

OA032 After 1 Hour

Page 27: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

OA032 After 5 Hours

Page 28: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Alternative Sacral Protector

Conforms

to Patient

Excellent Product, Unique!

AZ301

Offers

contoured

Lateral

protection

to Patient

Nerve

Protection/

Shear

Protection

Page 29: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Reddening of Skin?

• Cannot eliminate all pressure

• Reddening can occur after long cases

• If it is blanchable & clears within 30

minutes: No pressure damage has

occurred

Page 30: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

AZ300 After 1 Hour

Page 31: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

AZ300 After 5 Hours

Page 32: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Arm Adducted: Supine

OA110 Positioning

Belt

OA100

OA061

Page 33: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Supine - Trendelenberg

Brachial

Nerve

Elbow

Hand Knees

OA213 OA113 OA101

Page 34: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Arms

OP101

Page 35: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Arm Adducted: Supine

OA061

EL072

EL070

AZ201

Page 36: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Heels

AZ401

EL130

OA131

Page 37: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Lateral: Areas at Risk

Pressure Ulcer

Ear

Elbow

Hip: Greater

Trochanter

Knee

Ankle

Nerve

Damage

Musculo-

Skeletal

Shoulder:

Brachial

Plexus

Shoulder

dislocation

Elbow: Ulnar

Nerve

Lumbar

Strain

Page 38: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Lateral Position

Hip Hand Knees Ankles

OA200 OA071 OA050 OA031 OA061

Elbow Shoulder

Elbow

EL070 EL900

Page 39: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Head in Lateral

EL022

EL021

Open Head Ring

No Pressure on Eyes or Ears

Page 40: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Lateral: Leg Positioner

EL800

For Hip

Surgery

Page 41: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Lateral Position: Other Options

OA113

EL800 EL900 OA101 EL022

Page 42: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Lateral Park Bench Positioner

Recommended for Neurosurgery

ELP913

Page 43: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Lateral: Ankles

OA200

AZ500

Page 44: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Lateral: Vac Pacs

Page 45: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Neuropathy – Definition

Neuropathy is the term used when a nerve is

damaged. Motor, Sensory and Autonomic nerve

function can be affected

What is a Neuropathy?

“ ”

Page 46: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Perioperative Causes

• Stretch

• Compression

• Ischaemia

• Metabolic Derangement

• Surgical field

Neuropathy Effects

Ulnar Weak grip, flexion

‘Claw’ Hand

Sciatic Nerve Back Pain

Leg Pain

Common Peroneal Drop Foot

Loss of Sensation

Perioperative Neuropathy

Page 47: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Prone: Areas at Risk

Pressure Ulcer

Elbows

Hips: Iliac Crest

Knees

Toes / Feet

Nerve

Damage Specific

Considerations

Ocular

Nerve

Face: Eyes, Nose

Mouth

Brachial

Plexus

Respiratory

Insufficiency

Ulnar

Nerve

Breasts /

Genetalia

Page 48: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Prone Position

Hip Iliac Crest Knees Ankles Toes

EL030 EL210 EL401 EL905

Shoulder Brachial

Nerve

Elbow Ulnar

Nerve

EL072

Page 49: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Prone Position

Page 50: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Head in Prone

Protect Face & Soft Tissue – Eyes, Nose & Mouth

Facilitate Requirements for Safe Ventilation

EL141

OA030

Page 51: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Prone Positioner

Surgical Indication

Example Spinal Surgery

EL904

Page 52: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Prone Positioner

EL904 EL141 EL218

Eliminates Pressure on Abdomen &

Facilitates Ventilation

Page 53: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Prone: Oasis Options

Open Head Rings allow more access to airway

OA021

OA022

Page 54: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Prone: Alternative Foot / Ankle Support

EL216

EL215

EL214

EL217

EL218

Page 55: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Elite Positioners Prone Pad

Recommended for Laminectomy procedures and

surgery to the back of legs

ELP914

Page 56: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Lithotomy: Areas at Risk

Nerve Damage

Arms abducted:

Brachial Nerve Injury

Arms adducted:

Compartment syndrome

Elbow: Ulnar Nerve

Hamstrings overstretched:

Sciatic Nerve

Popliteal Fossa: Peroneal

Nerve

Pressure Ulcer

Occipital Region

Elbows

Sacrum

Page 57: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Lithotomy: Azure

Brachial

Nerve Sacrum

Perineal

Nerve

AZ410 AZ300 AZ201 AZ100

Elbow

Ulnar

Nerve

Page 58: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Alternative Sacral Protector

Stirrup too

high

= Hip joint

affected

Stirrup too

low

= Interferes

with

circulation

Pressure

on Sacrum

= Pressure

Ulcer

Pressure

on popliteal

fossa = Can

result in

Drop Foot

Page 59: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Lithotomy: Stirrup

Stirrup Pads Protect the Peroneal Nerve

Crutch

Stirrup

Pads

AZ410

OA090

OA091

OA092

Page 60: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Lithotomy: Options

Boot Stirrups, Heel/Ankle Protectors, Crutch Stirrups

Pads Protect the Peroneal Nerve

OA200 OA090

OA091

OA092

Page 61: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Lithotomy: Specific for GU or Gynae

Perineal Table Pad: Ideal when Irrigation required

OA040 EL031

Page 62: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Heating & Cooling

• Heat to +40 Degrees or

Cool to -12 Degrees

• Heat also by bathing in

warm water

Page 63: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Cleaning

• Should be disinfected after every patient

• Water based solutions

• Foam Or Cotton

• Single patient use (without cover)

• How are standards maintained?

• Costs of single use

• Greater risk of contamination

Please refer to Technical File Page 8

Page 65: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Repair

Temporary

Measure

Page 67: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Summary

Pressurecare

Page 68: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Pressure Sores & Injuries

• Costs of treatment higher than preventative measures.

• Cost to patient: Numerous!

• Pain, discomfort, prolonged hospital stay, altered body image

• Costs incurred by litigation high. JAMA 2006. Vol 296, No 8. Preventing Pressure Ulcers: A

Systematic Review

Page 69: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Implications of Clinical Practice

• Nurses play a vital role in pressurecare

• Must take part responsibility for positioning

• Nurse must act as patient advocate

• Risk assessment tool would be useful

• Be fully informed of equipment available to facilitate adequate pressurecare

• All OR Staff should be briefed on PC

Page 70: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Considerations

• Thoracic? Lateral positioners.

• Spinal? Prone positioners.

What types of surgery performed?

Age profile in the Hospital

• Orthopaedics? Older population at higher risk

• Paediatrics? Different range of products

Page 71: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Considerations Continued

• Have they enough equipment?

• Should be viewed as universal precaution

How many theatres in the Hospital?

Are staff trained on use of products?

• Theatre staff need regular updates and training

• Is there a Tissue Viability Nurse at the Hospital?

Page 72: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Comparison

Chart Trulife original

Competitor product:

Action

• Most comparable products to Action

• Industrial grade Silicone

• “Silicone shows resistance to

weathering which is important for the

long term life of the products”

• “ Silicone has close physical and

chemical relationship with human

skin”

NOT Silicone Gel

Viscoelastic Polymer

Contoured

• Contoured range – provides

enhanced positioning and nerve

protection

• 50% lighter

• Extensive range

Some equivalents on the market

• Anatomically designed

• Surrounding & Lateral Support –

Provides nerve protection

• Elastic properties – Superior pressure

relief

• 20% Lighter

No Equivalent

• Most durable range

• Anti-Slip

• Autoclavable

• Siloxane elastomers

No Equivalent

Page 73: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Testing & General Info

As its countermeasure, a gel type Horseshoe Headrest

recently has been introduced, resulting in reduced

frequency of decubitus ulcer

“ ”

• Technical guide at the back of the Pressure catalogue – covers

90% of questions

• We have an internal Q&A file for OR and Relax

• Test on Silicone v Polymer See tech file

• We have independent testing from PMI - DORO® Multi-Purpose

Skull Clamp

Page 74: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Testing Continued

” AORN Guidelines “ Foam and Gel mattresses are effective for

preventing both skin changes and pressure sore formation”

Chinese Clinical Application

For Oasis series position pads, the main material is a silica gel with

unique formula (TruGel). The main material is a unique formula

(trugel) silica gel with soft texture and good biological features which

allow the body weight to be evenly distributed onto the silica gel

without being compressed to an extreme state. Therefore, it provides

very good protection for the skin during surgical procedures.

AORN Guidelines

“ ”

Page 75: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Testing Continued

German Clinical Application

Manufacturer: pro med instruments GmbH

As its countermeasure, a gel type Horseshoe Headrest

recently has been introduced, resulting in reduced

frequency of decubitus ulcer. “

Page 76: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

MOVIES

Movies

General

Range

Azure

Range

General

Range

Elite

Trendelenburg

System

Oasis+

Production

Page 77: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

New Products

2018/2019

Pressurecare

Page 78: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

ICU Range

Page 79: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913
Page 80: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Elite Trendelenburg System

Designed to overcome the challenges of the

Trendelenburg position – patient slippage, nerve

injury and the formation of decubitus sores.

ELTS20

ELTS40

Page 81: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Best Sellers

Page 82: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

www.facebook.com/trulifegroup

Follow us on

www.linkedin.com/company/trulife

Page 83: Patient Positioning in Operating Roomtrulife.com/wp-content/uploads/OR-Full-training-2020.pdfEL800 EL900 OA101 EL022 . Lateral Park Bench Positioner Recommended for Neurosurgery ELP913

Conclusion

Superior and Quality Products

Innovative Research & Development

Offering the protection your

patient deserves!