PATenTeD SOUnD COnTrOl fOr 9/16 STeel DeCk COnSTrUCTIOn ...
Transcript of PATenTeD SOUnD COnTrOl fOr 9/16 STeel DeCk COnSTrUCTIOn ...
ACOUSTI-MAT®
SD PATenTeD SOUnD COnTrOl
fOr 9/16" STeel DeCk COnSTrUCTIOn
feATUreS & BenefITS• Fast, easy installation — requires just
one underlayment pour, speeding overall project time to completion
• UL Fire Designs• GREENGUARD Gold Certified• May help contribute toward points
for LEED® project certification• System warranty that covers both
Acousti-Mat SD and the Maxxon Underlayment
MEEt A toUGh SoUND CoNtRoL ChALLENGE with thE SMArT SOUnD COnTrOl SOlUTIOn
For proven, superior sound control in steel frame construction, Acousti-Mat SD
delivers the patented technology that meets the challenge. Designed to fit the flutes
of 9/16" – 21⁄2" o.c. corrugated steel decking, the Acousti-Mat SD System isolates
sound waves that historically have been difficult to control.
Fast, easy installation of Acousti-Mat SD is completed with the topping of a
high-strength Maxxon® Underlayment. No longer limited to “quiet” carpet and
pad alone, Acousti-Mat SD opens projects to any floor goods option, from vinyl
plank to wood to ceramic tile, without the associated sound transmission concerns.
ACOUSTI-MAT SDAlways a “Green” Building Material
Now, Even Steel Deck Construction has a Proven
Sound Control Solution
For more info: 800-356-7887 • Email: [email protected] www.MaxxonCorporation.com
MADE IN THE USAAnother superior product from: Maxxon® Corporation • 920 Hamel Road • P.O. Box 253 Hamel, MN 55340 USA • 763-478-9600 • Fax: 763-478-2431
Underwriters Laboratories Inc.® Listed
©2011–2014 Maxxon Corporation. All Rights Reserved. Acousti-Mat and associated logos are registered trademarks of Maxxon Corporation, Hamel, MN, USA. Printed in the USA. #62065, TA502-7176, 10/14.
SOUnD TeSTSUnderlayment Insulation Truss Depth Resilient
Channel Drywall Floor Covering Rating Test Number
11⁄2" (38 mm) 31⁄2" (89 mm) 12" (305 mm) Yes 2 layers 5/8" F-STC 59 A1472.16-201-10
11⁄2" (38 mm) 31⁄2" (89 mm) 12" (305 mm) Yes 2 layers 5/8" VCT F-IIC 49 A1472.01-201-10
11⁄2" (38 mm) 31⁄2" (89 mm) 12" (305 mm) Yes 2 layers 5/8" Floating Wood F-IIC 57 A1472.10-201-10
11⁄2" (38 mm) 31⁄2" (89 mm) 12" (305 mm) Yes 2 layers 5/8" Tile Ceramic F-IIC 51 A1472.07-201-10
11⁄2" (38 mm) 31⁄2" (89 mm) 12" (305 mm) Yes 2 layers 5/8" Vinyl F-IIC 55 A1472.04-201-10
11⁄2" (38 mm) 31⁄2" (89 mm) 12" (305 mm) Yes 2 layers 5/8" Carpet and Pad F-IIC 83 A1472.13-201-10
11⁄2" (38 mm) 31⁄2" (89 mm) 12" (305 mm) Yes 5/8" (16 mm) F-STC 57 A1472.17-201-10
11⁄2" (38 mm) 31⁄2" (89 mm) 12" (305 mm) Yes 5/8" (16 mm) VCT F-IIC 48 A1472.02-201-10
11⁄2" (38 mm) 31⁄2" (89 mm) 12" (305 mm) Yes 5/8" (16 mm) Floating Wood F-IIC 55 A1472.11-201-10
11⁄2" (38 mm) 31⁄2" (89 mm) 12" (305 mm) Yes 5/8" (16 mm) Tile Ceramic F-IIC 51 A1472.08-201-10
11⁄2" (38 mm) 31⁄2" (89 mm) 12" (305 mm) Yes 5/8" (16 mm) Vinyl F-IIC 52 A1472.05-201-10
11⁄2" (38 mm) 31⁄2" (89 mm) 12" (305 mm) Yes 5/8" (16 mm) Carpet and Pad F-IIC 76 A1472.14-201-10
11⁄2" (38 mm) 31⁄2" (89 mm) 12" (305 mm) N/A Suspended 5/8" F-STC 57 A1472.18-201-10
11⁄2" (38 mm) 31⁄2" (89 mm) 12" (305 mm) N/A Suspended 5/8" VCT F-IIC 51 A1472.03-201-10
11⁄2" (38 mm) 31⁄2" (89 mm) 12" (305 mm) N/A Suspended 5/8" Floating Wood F-IIC 54 A1472.12-201-10
11⁄2" (38 mm) 31⁄2" (89 mm) 12" (305 mm) N/A Suspended 5/8" Tile Ceramic F-IIC 51 A1472.09-201-10
11⁄2" (38 mm) 31⁄2" (89 mm) 12" (305 mm) N/A Suspended 5/8" Vinyl F-IIC 53 A1472.06-201-10
11⁄2" (38 mm) 31⁄2" (89 mm) 12" (305 mm) N/A Suspended 5/8" Carpet and Pad F-IIC 73 A1472.15-201-10
11⁄2" (38 mm) 31⁄2" (89 mm) 91⁄4" (235 mm) Yes 5/8" (16 mm) Quarry Tile IIC 51 7008081
11⁄2" (38 mm) 31⁄2" (89 mm) 91⁄4" (235 mm) Yes 5/8" (16 mm) STC 57 5008033
FiRE RAtiNGSUL# Hour Rating Type of Construction
G551 1, 2 Clark/Dietrich Building Systems Steel Joist 24" o.c. with min 9/16” deep, 22 MSG corrugated steel deck, resilient channel
G553 1, 2 Clark/Dietrich Building Systems Steel Joist 24" o.c. with min 9/16” deep, 22 MSG corrugated steel deck, resilient channel
G560 2 Dietrich industries Steel Joist, 24" o.c. with 22 MSG corrugated steel deck
G561 1, 2 Vulcraft Corrugated Steel Floor and Form Units topped with 21⁄2" Concrete
G563 1 Marino\wARE Steel Joist, 24" o.c. with 22 MSG corrugated steel deck
G566 1 Gateway Panel Steel Joist, 24" o.c. with 22 MSG corrugated steel deck
G574 1 California Expanded Metal Company Steel Joist, 24" o.c. with 22 MSG corrugated steel deck
SteelStud
Reinforcement
MaxxonFloorPrimer
Maxxon approved reinforcement
Corrugated Steel DeckAcousti-Mat SD
Gypsum Board*
Wall isolation**
Acoustical Sealant 1 " approved Maxxon Underlayment
Acousti-Mat Tapeor equivalent
Acousti-Mat SD on Corrugated Steel Deck®
®
®
12
DEtAiL DRAwiNGS
Resilient Channel
Acousti-MatSD
Reinforcement
Batt Insulation
5/8" (16 mm) Gypsum Board
22 MSG galv corrugated fluted steel deck 9/16"
(15 mm) deep
11⁄2" (38 mm) minimum Maxxon® Underlayment
11⁄2 "
91⁄4" (231 mm) Steel Joist
LEED® INFORMATIONFor information regarding how Acousti-Mat SD may contribute toward points for LEED project
contribution, contact your Regional Representative at (800) 356-7887 or visit www.maxxon.com/go_green.
SoUND tESt iNFoRMAtioN: All acoustical testing was done by Architectural Testing; Riverbank Testing Laboratories; Intest, Inc.; Twin City Testing Corporation; Maxxon R&D Test Center; D.L. Adams Associates, L.T.D.; Veneklasen Associates; NGC Testing Services; AV Group or JGL Acoustics. For type of floor covering used, channel spacing and other information, contact Maxxon for test reports by number. International Building Code (IBC) requires a minimum 50 STC/IIC (45 F-STC/F-IIC) in multifamily construction. Because an STC/IIC of 50 provides only marginal sound control, the International Code Council (ICC), author of the IBC, now recommends that an “acceptable” level of performance for both STC and IIC is 55 (52 if field tested). The “preferred” level of performance for STC and IIC is 60 (57 if field tested). Maxxon Underlayments and Acousti-Mat are but single components of an effective sound control system. No sound control system is better than its weakest component. Care must be taken in the installation of all components of construction to ensure the ultimate designed acoustical performance.wARRANtY: Maxxon® Corporation warrants Acousti-Mat® SD to be free from manufacturing defects as defined in this warranty. Manufacturing defects are considered to be those defects that occur due to the quality of the ingredients or from the manufacturing process itself. This warranty does not include labor costs and other costs or expenses associated with the removal or installation of Acousti-Mat SD. Because Maxxon Corporation does not perform the actual installation, it cannot be held responsible for the results of the application. Maxxon Corporation specifically disclaims problems that occur due to weather conditions, structural movement, structural design flaws and appli-cation techniques. This warranty is in lieu of all other warranties expressed or implied including the warranty of merchantability and fitness of a particular purpose and of all other obligations or liabilities on Maxxon Corporation’s part. Maxxon Corporation neither assumes nor authorizes any person to assume for Maxxon Corporation any liability in connection with the sale and installation of Acousti-Mat SD.
tEChNiCAL DAtA
Thickness, nominal .....7/8" (21 mm) pyramids with 1/4" (6 mm) minimum between peaks
Description .............. Black mesh with water resistant fabric, 40% pre-consumer recycled
Density ............................................. 1.92 pcf (30.7 kg/m3)
Mat only ..........................................................1.440Underlayment ....................................................0.288Mat/Underlayment .............................................1.728
Thermal Resistance R-Value (ft2•°F•h/BtU)
50 psf (244 kg/m2) .......................... 0.034" (0.86 mm)100 psf (488 kg/m2) ........................ 0.064" (1.63 mm)200 psf (976 kg/m2) ........................ 0.115" (2.92 mm)300 psf (1464 kg/m2) ...................... 0.175" (4.45 mm)
Pressure/Deflection
Fuel Contribution .......................................................0Smoke Density ..........................................................0Flame Spread .........................................NFPA Class A
Fire Performance AStM E-84
Maxxon Underlayment w/ Reinforcement ....11⁄2" (38mm)Underlayment Depth
FiRE/SoUND RAtiNGSEvaluation Reports - Meeting fire and sound code together
Accepted by local building officials for fire and sound code compliance, Evaluation Reports are technical reports which verify that specific products meet the following code requirements and warrant regulatory approval. Minimum code requirements: Sound - 50 STC/IIC, Fire - I Hour
International Code CouncilICC ESR #2540 For the following assembly types:
Additional ICC ES Reports: ESR #1141, ESR #1153, ESR #1774
Underwriters Laboratory InternationalUL ER #8477-01 For the following assembly types:• Parallel Chord Truss• 2x10 Wood Truss
• I-Joist• Hambro
• Steel Joist• Precast Concrete
• Parallel Chord Truss• 2x10 Wood Truss
• I-Joist• Steel Joist
• Precast Concrete