Patent Ductus and Vascular Occlusion Devices
Michelle Carlsen
Elaine Isom
Brad Klosterman
Ornob Roy
Advisor: Dr. Thomas Doyle
![Page 2: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/2.jpg)
Project Definition
• Objective: Design, build, and market an occlusion device which can be used to close the Patent Ductus and cylindrical vasculature
• Presentation topics: – Background
– solution
– accomplishments
– current status
– future plans
![Page 3: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/3.jpg)
Background:Patent Ductus
• Condition affecting Infants/Children
• ~ 10-12% of congenital defects• 40 cases/yr at Vanderbilt• > 20,000 nationwide• Connection btw pulmonary
artery and aorta
![Page 4: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/4.jpg)
Background:General Vasculature
• Less common than PDA• Cylindrical shape• Reroute blood flow• Isolate defective vasculature• Impede significant flow
![Page 5: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/5.jpg)
PDA/ Vascular Conditions
• Diagnosis:– Heart murmur
– Extreme weight loss
– Stunted growth
– Irregular blood flow*
* General vasculature
• Consequences:– Irreversible pulmonary-
vascular disease
– Congestive heart failure
– Hemorrhaging (e.g. diabetics, post-surgical patients)*
![Page 6: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/6.jpg)
Requirements
• Biocompatible
• Quick endothelialization (1-2months)
• Delivered through a catheter < 2mm diameter
• Simple, Retrievable
• Inexpensive
• Various size (2 to 10mm)
• Form-fitting
• Maximum effectiveness
– Internal device– Complete closure
– Standard catheter size
– Minimum training– Cost effective - comparatively– Universal Device– Immovable and closure– No leakage
![Page 7: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/7.jpg)
Current Solutions
• Endomethiasin
– initial form of treatment
– steroid medicine (vasoconstrictor)
– restricted to premature infants
• Suturing
– effective
– invasive, long recovery
• Coils– inexpensive– not form fitting
• Titanium devices– form fitting– very expensive
• Ultrasonic Devices– non-invasive– high-intensity– not human tested
![Page 8: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/8.jpg)
Accomplishments
• Identification of associated diseases
• Analysis of previous device designs
• Studies in biocompatible materials (Prof. Kinser, Material Sciences)
• Fluoroscopy viewing
• SDRC I-DEAS CAD/CAM modeling
• Began mock circulation system
![Page 9: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/9.jpg)
I-DEAS Modeling
• Goal– allow for quick and
accurate prototyping
– marketing and visualization
![Page 10: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/10.jpg)
Current Status
• 3D modeling using SDRC I-DEAS
• Material search
• 4 design concepts
• Large scale simulation: drawings, materials, construction
![Page 11: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/11.jpg)
Design 1
Advantages:
•adjust on contact
•expandable polymer
•form-fitting (PDA & general)
Disadvantages:
•FDA
•expensive (polymer & wire
•retrievable??
![Page 12: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/12.jpg)
Design 2
Advantages:
•form-fitting (PDA & general)
•collapsible (>500%)
•endothelialize quickly
•inexpensive
Disadvantages:
•complex
•possible limited retrieval
![Page 13: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/13.jpg)
Design 3
• Advantages
– very rigid
– easily retrievable
– adjustable
• Disadvantages– difficult to maneuver
– expensive
![Page 14: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/14.jpg)
Design 4
Advantages:
•form-fitting (PDA & general)
•retrievable
•simple
•inexpensive
Disadvantages:
•expansion limitations??
•Two materials
![Page 15: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/15.jpg)
Material Search
• Zotefoams– plastazote foam (polyethylene)
• Medicell– medical sponges
• Titanium/wire material
• Thrombosing fibers
• Polyurethane foam (earplugs)
• Polyurethane that is modified with lower alkyl Sulfonate and L(L-glutamic acid co L-leucine)– biocompatible, used in surgical implantations and blood contacting
procedures
![Page 16: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/16.jpg)
Suitable Materials
• Hydromer– Medicell Hydrophilic Open Cell Medical Foam– consists of polyurethane and
polyvinylpyrrolidone polymers
• Foamex– Functional Flexibility
• Titanium Feet
![Page 17: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/17.jpg)
Simulation
Echigo, S et al. “ Development of New Transvenous Patent Ductus Arteriosis Occlusion Technique Using a Shape Memory Polymer.” ASAIO Transactions: 1990 pg M197.
![Page 18: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/18.jpg)
Simulation Protocol
• Large scale
• Fluid:– water glucose mixture– pig’s blood
• Pulsatile Pump
• Latex Tubing (18 flexitube)
• Plastic PDA (conical 2mm opening)
![Page 19: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/19.jpg)
Division of Labor
• Elaine/Michelle:– PDA design
– material search
– literature analysis/search
• Ornob/Brad:– Vascular Occluder Design
– modeling using I-DEAS
– simulation design idea, construction
• Group:– device design ideas
– large scale prototypes
– designsafe analysis
![Page 20: Patent Ductus and Vascular Occlusion Devices](https://reader036.fdocuments.in/reader036/viewer/2022062409/56815065550346895dbe64d5/html5/thumbnails/20.jpg)
Future Plans
• Decide on final design
• Acquire materials for design
• Continue meeting with Dr. Doyle
• Designsafe analysis
• Large scale replication
• Patent