EID/Z/I-05:1584 Uin Rev A Limited Internal Instalasi RBS 2206/2106 2005-12-19 Agenda Training Pendahuluan, pengenalan ASP dan proses lisensi Mengisi Form CV, foto, interview Pengenalan RBS 2206, RBS 2106, antena Instalasi indoor MBL Indoor Istirahat Kegiatan 1 : Pengenalan produk & Instalasi indoor Instalasi Outdoor Kegiatan 2 : Instalasi Outdoor Makan siang Kegiatan 3 : Ketrampilan Instalasi Ceklist Instalasi Kesadaran kualitas & kebiasaan bekerja Istirahat MBL Ethics & Manners MBL Quality Issues Kegiatan 4 : Kualitas dan kebiasaan kerja Tes teori dan penilaian 09.00 16.00

description

Instalasi GSM RBS 2206/2106

Transcript of Part 2 Instalasi GSM RBS 2206/2106

Page 1: Part 2 Instalasi GSM RBS 2206/2106

EID/Z/I-05:1584 Uin Rev A Limited Internal Instalasi RBS 2206/2106 2005-12-19

Agenda Training

Pendahuluan, pengenalan ASP dan proses lisensiMengisi Form CV, foto, interviewPengenalan RBS 2206, RBS 2106, antenaInstalasi indoorMBL IndoorIstirahatKegiatan 1 : Pengenalan produk & Instalasi indoorInstalasi OutdoorKegiatan 2 : Instalasi OutdoorMakan siangKegiatan 3 : Ketrampilan InstalasiCeklist InstalasiKesadaran kualitas & kebiasaan bekerjaIstirahatMBL Ethics & MannersMBL Quality IssuesKegiatan 4 : Kualitas dan kebiasaan kerjaTes teori dan penilaian

09.00

16.00

Page 2: Part 2 Instalasi GSM RBS 2206/2106

RBS 2206/2106 dan Antena

Pendahuluan

Page 3: Part 2 Instalasi GSM RBS 2206/2106

EID/Z/I-05:1584 Uin Rev A Limited Internal Instalasi RBS 2206/2106 2005-12-19

RBS 2206 Desain IndoorUkuran : 1850 x 600 x 400 mmBerat : 230 kgInput AC : 230VAC, -48VDC, +24VDC (wide range)Konsumsi Daya : max 3900W pada teganganACGSM 800, GSM 900, GSM 1800 atau GSM 1900Kapasitas 12 transceiverTransmisi 75/120/100 ohmDaya Output : 35 W Temperatur: +5°C sampai +40°CCadangan catu daya eksternal dengan bateraisampai 8 jamTaraf kebisingan : 58 dB (>85 dB berbahaya!)16 alarm input eksternal

Page 4: Part 2 Instalasi GSM RBS 2206/2106

EID/Z/I-05:1584 Uin Rev A Limited Internal Instalasi RBS 2206/2106 2005-12-19

RBS 2206

CDU - G

CXU

d -TRU

IDM

DXU - 21

Trafik (E1), Binary Alarm

PSU

OXU 1 - 4

OXU - 5

ACCU / DCCU

FCU

DC Filter

Page 5: Part 2 Instalasi GSM RBS 2206/2106

EID/Z/I-05:1584 Uin Rev A Limited Internal Instalasi RBS 2206/2106 2005-12-19

Panel Depan RBS 2206

DC Filter

Fan Control Unit (FCU)

PCM Link (E1)

DC out +24VDC

16 Binary Alarms

ESB Connection

AC/DC Connection

Unit

+24 VDC Battery Backup

Cabinet Grounding Connection

GG--703.2703.2GG--703.1703.1

GG--703.3703.3 GG--703.4703.4

ESB 1ESB 1

ESB 2ESB 2

ACCU 230 VAC DCCU -48 VDC

TMA Connection

Field

+24 VDC

Page 6: Part 2 Instalasi GSM RBS 2206/2106

EID/Z/I-05:1584 Uin Rev A Limited Internal Instalasi RBS 2206/2106 2005-12-19

RBS 2106Ukuran : 1614 x 1300 x 940 mmBerat: 560 kg + 2,4 or 6 batteries Input Power AC : 230 VACKonsumsi Daya: max 5570 WGSM 900, GSM 1800 or GSM 1900Kapasitas 12 transceiverTransmisi 75/120/100 ohmDaya output : 33 W (57 W with TCC)Desain weatherproof/vandalproofTemperatur (-33°C up to +45°C)1 Jam backup daya terintegrasiatau kabinet baterai eksternalTaraf kebisingan: 60 dB(>85 dB berbahaya!)16 input alarm eksternal

Page 7: Part 2 Instalasi GSM RBS 2206/2106

EID/Z/I-05:1584 Uin Rev A Limited Internal Instalasi RBS 2206/2106 2005-12-19

RBS 2106

IDM

PSU

DXU

AC-PDU

Battery

Transmission Rack

DF (OVP Alarm;PCM)Main Sw

BFU

ADM

DC/DC

dTRU

CXU

CDU-G

FCU

Page 8: Part 2 Instalasi GSM RBS 2206/2106

EID/Z/I-05:1584 Uin Rev A Limited Internal Instalasi RBS 2206/2106 2005-12-19

RBS 2106 dengan BBU 9500

Rak baterai terpisah

Kapasitas 2 bank

Page 9: Part 2 Instalasi GSM RBS 2206/2106

EID/Z/I-05:1584 Uin Rev A Limited Internal Instalasi RBS 2206/2106 2005-12-19

Battery Backup System BBS2000

Di desain untuk indoor RBS 2206, 2207, dan 2202

Jika listrik padam, BBS 2000 akan mengalirkan suplaitegangan ke RBS dan ke peralatan transmisi (contoh: Mini-Link)

BFU (Battery Fuse Unit) secara otomatis bertugasmenghubungkan/memutus koneksi ke RBS/Transmisi

Jika tegangan yang diperlukan adalah –48 Volt, makadiperlukan DC/DC Converter unit dipasang di BBS 2000

Page 10: Part 2 Instalasi GSM RBS 2206/2106

EID/Z/I-05:1584 Uin Rev A Limited Internal Instalasi RBS 2206/2106 2005-12-19

Bagian-bagian BBS 2000

Baterai

BFU-EDC-DC

Page 11: Part 2 Instalasi GSM RBS 2206/2106

EID/Z/I-05:1584 Uin Rev A Limited Internal Instalasi RBS 2206/2106 2005-12-19

Interkoneksi kabel BBS 2000

Kabel Opto

(EPC Bus)

Sensor Suhu

Suplai MiniLink

Page 12: Part 2 Instalasi GSM RBS 2206/2106

EID/Z/I-05:1584 Uin Rev A Limited Internal Instalasi RBS 2206/2106 2005-12-19

Antena RBS

Antena dual polarized (x-pole)

Antena single polarized (v-pole)

Page 13: Part 2 Instalasi GSM RBS 2206/2106

EID/Z/I-05:1584 Uin Rev A Limited Internal Instalasi RBS 2206/2106 2005-12-19

Antena Single Polarized

Cell A = 0o DX1

Cell A = 0o

DX2

Cell B = 120o

DX1

Cell B = 120o

DX2

Cell C = 240o

DX2

Cell C = 240o

DX1

Page 14: Part 2 Instalasi GSM RBS 2206/2106

EID/Z/I-05:1584 Uin Rev A Limited Internal Instalasi RBS 2206/2106 2005-12-19

Antena Dual Polarized

Antena Tampak Depan

DX2 DX1

Electrical Tilt

Cell A = 0o

Cell B = 120o

Cell C = 240o

Page 15: Part 2 Instalasi GSM RBS 2206/2106

EID/Z/I-05:1584 Uin Rev A Limited Internal Instalasi RBS 2206/2106 2005-12-19

Distribution Frame (DF) Unit

Distribution Frame adalah modulyang di gunakan untuk memasangalarm eksternal ataupun OVP (Over Voltage Protection)

Ada 16 Alarm Input Eksternal yang dapat dipasang

OVP

EksternalAlarm

Page 16: Part 2 Instalasi GSM RBS 2206/2106

EID/Z/I-05:1584 Uin Rev A Limited Internal Instalasi RBS 2206/2106 2005-12-19