Hydraulic Pump T7/T67/T6C Series Industrial Vane Pumps Pressure up to 320 bar Fixed Displacement from 6 to 637 ml/rev. Catalogue HY29-0001/UK March 2007

Transcript of Parker Vane Pump

Page 1: Parker Vane Pump

Hydraulic PumpT7/T67/T6C SeriesIndustrial Vane PumpsPressure up to 320 barFixed Displacement from 6 to 637 ml/rev.

Catalogue HY29-0001/UKMarch 2007

Page 2: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

2 Parker HannifinDenison Vane Pump DivisionVierzon - France

General characteristics ....................................................................... 4Min. and max. speeds - Pressure ratingsSingle pumps ................................................................................ 5 - 6Min. and max. speeds - Pressure ratingsDouble & triple pumps ....................................................................... 7 Minimum allowable inlet pressure ............................................... 8 - 9Main calculation ............................................................................... 10Intermittent pressure rating .............................................................. 10Description ....................................................................................... 11Start-up instructions & recommendationsGeneral ..................................................................................... 12 - 13 Shaft & coupling data ...................................................................... 13Specific point ................................................................................... 13Fluids ........................................................................................ 13 - 14Formulas .......................................................................................... 14General characteristics ............................................................. 15 - 16Notes ................................................................................................ 17

Ordering code and technical data ..................................................... 18Dimensions and operating characteristics ........................................ 19

Ordering code and technical data ..................................................... 20Dimensions and operating characteristics ........................................ 21

Ordering code and technical data ..................................................... 22Dimensions and operating characteristics ........................................ 23

Ordering code and technical data ..................................................... 24Dimensions and operating characteristics ........................................ 25

Ordering code and technical data ..................................................... 26Dimensions and operating characteristics ........................................ 27

Ordering code and technical data ..................................................... 28Dimensions and operating characteristics ........................................ 29

Ordering code and technical data ..................................................... 30Dimensions and operating characteristics ........................................ 31

Ordering code and technical data ..................................................... 32Dimensions and operating characteristics ........................................ 33

Ordering code and technical data ..................................................... 34Dimensions and operating characteristics ........................................ 35

Ordering code and technical data ..................................................... 36Dimensions and operating characteristics ........................................ 37

Ordering code and technical data ..................................................... 38Dimensions and operating characteristics ........................................ 39

Ordering code and technical data ..................................................... 40Dimensions and operating characteristics ........................................ 41

Ordering code and technical data ..................................................... 42Dimensions and operating characteristics ........................................ 43

General

SInGle T7aS

T7aSW

T7B-T7BS

T6C

T7D-T7DS

T7e-T7eS

DOUBle T7BB-T7BBS

T6CC

T67CB

T7DB-T7DBS

T67DC

T7DD-T7DDS

T7eB-T7eBS

Content

Page 3: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

� Parker HannifinDenison Vane Pump DivisionVierzon - France

Ordering code and technical data ..................................................... 44Dimensions and operating characteristics ........................................ 45

Ordering code and technical data ..................................................... 46Dimensions and operating characteristics ........................................ 47

Ordering code and technical data ..................................................... 48Dimensions and operating characteristics ........................................ 49

Ordering code and operating characteristics .................................... 50Technical data .................................................................................. 51Dimensions ...................................................................................... 52

Dimensions ...................................................................................... 52 Ordering code and operating characteristics .................................... 53 Technical data .................................................................................. 54

Technical data .................................................................................. 55 Ordering code and operating characteristics .................................... 56Dimensions ...................................................................................... 52

Ordering code and operating characteristics .................................... 57 Technical data .................................................................................. 58 Dimensions ...................................................................................... 59

Dimensions ...................................................................................... 60 Ordering code and operating characteristics .................................... 61 Technical data .................................................................................. 62

Technical data .................................................................................. 63 Ordering code and operating characteristics .................................... 64 Dimensions ...................................................................................... 65

Dimensions ...................................................................................... 66 Ordering code and operating characteristics .................................... 67 Technical data .................................................................................. 68

Technical data .................................................................................. 69Ordering code and operating characteristics .................................... 70 Dimensions ...................................................................................... 71

Porting diagrams for double and triple pumps .................................. 72 Porting diagrams for triple pumps ................................................... 73

Notes ................................................................................................ 74

Warning .............................................................................................75

T67eC

T7eD-T7eDS

T7ee-T7eeS

TrIPle T7DBB-T7DBBS

T7DCB-T7DCBS

T7DCC-T7DCCS

T7DDB-T7DDBS

T67DDCS

T7eDB-T7eDBS

T67eDC-T67eDCS

T7eeC-T7eeCS

Content

Page 4: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

� Parker HannifinDenison Vane Pump DivisionVierzon - France

Characteristics

These vane pumps have been specially designed for high/low circuits. The combination of different cartridges in double and triple pumps allows low flow at high pressure (300 bar max.) and high flow at lower pressure. This is a clever way to optimize your circuit design.This pump feature will also allow a very fast pressure cycle change with a very precise flow repeatability.

Size A : 5,8 to 40,0 ml/rev.Size B : 5,8 to 50,0 ml/rev.Size C : 10,8 to 100,0 ml/rev.Size D : 44,0 to 158,0 ml/rev.Size E : 132,3 to 268,7 ml/rev.

A : up to 300 bar max.B : up to 320 bar max. (300 bar for multiple pump).C : up to 275 bar max.D : up to 280 bar max. (250 bar for multiple pump).E : up to 240 bar max.

Industrial pumps : Min. : 600 RPM - Max. up to 3600 RPM

Increases productivity, reduces heating and reduces operation costs.

Increases operator safety and eases machines acceptances.

Single pumps : 4 different positions.Double pumps : 32 different positions.Triple pumps : 128 different positions.

Provides for drop-in assemblies. They permit easy conversion and service.A, B and D cartridges : bi-directional technology.C and E cartridges : uni-directional technology.

Viscosities from 860 to 10 cSt permit colder starts and hotter running. The balanced design compensates for wear and temperature changes. At high viscosity or cold temperature, the rotor to side plates gap is well lubricated and improves mechanical efficiency.

Phosphate esters, organic esters, chlorinated hydrocarbons, water glycols, rapeseed may be pumped at high pressures and with long service life by these pumps.

1. Check speed range, pressure, temperature, fluid quality, fluid visco-sity and pump rotation.2. Check inlet conditions of the pump, if it can accept the application requirements.3. Check the type of shaft : if it will support the operating torque.4. Check the coupling must be chosen to minimize pump shaft load (weight, misalignment).5. Filtration : must be adequate for the lowest contamination level.6. Check the environment of the pump : as to avoid noise reflection, pollution and shocks.

CHARACTERISTICS

GREATER FLOW

HIGHER PRESSURE

WIDE SPEED RANGE

BETTER EFFICIENCY

LOW NOISE LEVELS

MOUNTING FLEXIBILITY

CARTRIDGE DESIGN

WIDE RANGE OF ACCEPTABLE VISCOSITIES

FIRE RESISTANT FLUIDS AND BIODEGRADABLE FLUIDS

GENERAL APPLICATIONS INSTRUCTIONS

Page 5: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

� Parker HannifinDenison Vane Pump DivisionVierzon - France

Singlepumps:speeds,pressureratings

Model of pump

Series

Theoretical Displacement

Vi

Minimum Speed

Maximum Speed 3) Maximum Pressure

HF-0, HF-1HF-2

HF-3, HF-4HF-5

HF-0, HF-2 HF-1, HF-4, HF-5 HF-3

Int. Cont. Int. Cont. Int. Cont.

ml/rev. RPM RPM RPM bar bar bar bar bar bar

T7AS2)

B06 5,8

6003600

1800300 275

240 210 175 140

B10 9,8

B11 11,0

B13 12,8

B17 17.2

B20 19,8

B22 22,5

B25 24,9 3000 275 240

T7ASW2)

B26 26,0

600

3600

1800

300 275

240 210 175 140

B28 28,0

B30 30,0

B32 31,8

B34 34,0

3000 280 240B36 36,0

B40 40,0

T7BT7BS

B02 5,8

600

3600

1800

3201) 290

240 210 175 140

B03 9,8

B04 12,8

B05 15,9

B06 19,8

B07 22,5

B08 24,9

B09 28,0

B10 31,8

B11 35,0

3000300 275B12 41,0

B14 45,0

B15 50,0 280 240

T6C

003 10,8

600

2800

1800

275 240

210

175

175 140

005 17,2

006 21,3

008 26,4

010 34,1

012 37,1

014 46,0

017 58,3

020 63,8

022 70,3

025 79,3

2500028 88,8210 160 160

031 100,0

HF-0, HF-2 = Antiwear Petroleum Base - HF-1 = Non Antiwear Petroleum Base - HF-3 = Water in oil Invert EmulsionsHF-4 = Water Glycols Solutions - HF-5 = Synthetic Fluids

1) Please consult Parker Denison for application over 300 bar.2) Please be careful as these cartridge designation are now in ml/rev. (example : B22 = 22,5 ml/rev.)3) Please be sure that the inlet velocity is under 1,9 m/sec. (see page 12, start-up & check-up).

For further information, or if the performance characteristics outlined here above do not meet your particular requirements, please consult your local Parker Denison office.

Page 6: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

� Parker HannifinDenison Vane Pump DivisionVierzon - France

Model of pump

Series

Theoretical Displacement

Vi

Minimum Speed

Maximum Speed 3) Maximum Pressure

HF-0, HF-1HF-2

HF-3, HF-4HF-5

HF-0, HF-2 HF-1, HF-4, HF-5 HF-3

Int. Cont. Int. Cont. Int. Cont.

ml/rev. RPM RPM RPM bar bar bar bar bar bar

T7DT7DS

B14 44,0

600

3000

1800

300

250240 210

175 140

B17 55,0

B20 66,0

B22 70,3

B24 81,1

B28 90,0

B31 99,2

B35 113,42800 280

B38 120,6

B42 137,5 2500 260 230

0451) 145,72200

240 210210

175

0501) 158,0 210 160 160

T7E 2)

T7ES

042 132,3

6002200

1800240 210 210 175 175 140

045 142,4

050 158,5

052 164,8

054 171,0

057 183,3

062 196,7

066 213,3

072 227,1

085 268,7 2000 90 75 75 75 75 75

Singlepumps:speeds,pressureratings

HF-0, HF-2 = Antiwear Petroleum BaseHF-1 = Non Antiwear Petroleum BaseHF-3 = Water in oil Invert EmulsionsHF-4 = Water Glycols SolutionsHF-5 = Synthetic Fluids

1) Ten vane technology.2) For T7E, below 10 bar, please contact Parker Denison.3) Please be sure that the inlet velocity is under 1,9 m/sec. (see page 12, start-up & check-up).

For further information, or if the performance characteristics outlined here above do not meet your particular requirements, please consult your local Parker Denison office.

Page 7: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

� Parker HannifinDenison Vane Pump DivisionVierzon - France

Double&triplepumps:speeds,pressureratings

Model of pump

Series

Theoretical Displacement

Vi

Minimum Speed

Maximum Speed 3) Maximum Pressure

HF-0, HF-1HF-2

HF-3, HF-4HF-5

HF-0, HF-2 HF-1, HF-4, HF-5 HF-3Int. Cont. Int. Cont. Int. Cont.

ml/rev. RPM RPM RPM bar bar bar bar bar bar

T7BB/ST67CBT7DB/ST7EB/ST7DBB/ST7DCB/ST7DDB/ST7EDB/S

B02 5,8

600 22002) 1800

T7BBT7BBS

3201)

Otherpumps

300

T7BBT7BBS

290

Otherpumps

275

240 210 175 140

B03 9,8

B04 12,8

B05 15,9

B06 19,8

B07 22,5

B08 24,9

B09 28,0

B10 31,8

B11 35,0

B12 41,0

B14 45,0

B15 50,0 280 240

T6CCT67CBT67DCT67ECT7DCB/ST7DCC/ST67DDCST67EDC/ST7EEC/S

003 10,8

600 22002) 1800

275 240

210

175

175 140

005 17,2

006 21,3

008 26,4

010 34,1

012 37,1

014 46,0

017 58,3

020 63,8

022 70,3

025 79,3

028 88,8210 160 160

031 100,0

T7DB/ST67DCT7DD/ST7EDST7DBB/ST7DCB/ST7DCC/ST7DDB/ST67DDCST7EDB/ST67EDC/S

B14 44,0

600 22002) 1800

300

250240 210

175 140

B17 55,0

B20 66,0

B22 70,3

B24 81,1

B28 90,0

B31 99,2

B35 113,4280

B38 120,6

B42 137,5 260 230

0451) 145,7 240 210210

175

0501) 158,0 210 160 160

T7EB/ST67ECT7EDST7EE/ST7EEC/ST67EDB/ST67EDC/S

042 132,3

60022002)

1800240 210 210 175 175 140

045 142,4

050 158,5

052 164,8

054 171,0

057 183,3

062 196,7

066 213,3

072 227,1

085 268,7 2000 90 75 75 75 75 75

HF-0, HF-2 = Antiwear Petroleum Base HF-1 = Non Antiwear Petroleum Base HF-3 = Water in oil Invert EmulsionsHF-4 = Water Glycols Solutions HF-5 = Synthetic Fluids1) Please consult Parker Denison for application over 300 bar.2) Please consult Parker Denison with higher speeds.3) Please be sure that the inlet velocity is under 1,9 m/sec. (see page 12, start-up & check-up).

For further information or if the performance characteristics outlined above do not meet your particular requirements, please consult your local Parker Denison office.

Page 8: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

� Parker HannifinDenison Vane Pump DivisionVierzon - France

Cartridge Speed RPMSeries

Size Series 1200 1500 1800 2100 2200 2300 2500 2800 3000 3600

AS

B06

0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,800,80

0,80

B06

B10 B10

B11 B11

B13 B13

B17 0,88 B17

B20 0,94 B20

B22 1,00 B22

B25 0,85 B25

ASW

B26

0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80 0,80

0,80

B26

B28 B28

B30 B30

B32 B32

B34 0,88 B34

B36 0,94 B36

B40 1,00 B40

B

B02

0,80 0,80 0,80 0,80 0,80 0,80

0,80 0,80

0,80 0,80

B02

B03 B03

B04 B04

B05 B05

B060,82 0,98

B06

B07 B07

B080,85 1,05

B08

B09 B09

B10

0,90

1,15 B10

B11 B11

B12 B12

B140,84 0,99 1,13

B14

B15 B15

C

003

0,80 0,80 0,80

0,80

0,80

0,80 0,90

1,00

003

005 005

006 006

008 008

0100,85

0,92 010

012

0,95

012

0140,85

0,901,03

014

017 017

020 0,85 0,90 0,98 1,05 020

0220,90

0,95 0,95 1,05 022

028 0,98 0,98 1,08 028

031 0,85 0,90 1,11 1,11 031

Inlet pressure is measured at inlet flange with petroleum base fluids at viscosity between 10 and 65 cSt. The difference between inlet pressure at the pump flange and atmospheric pressure must not exceed 0,2 bar to prevent aeration.Multiply absolute pressure by 1,25 for HF-3, HF-4 fluids. by 1,35 for HF-5 fluid. by 1,10 for ester or rapeseed base.For double and triple pumps, prefer the cartridge requiring the highest absolute pressure.

Minimumallowableinletpressure(barabsolute)

Minimum allowable inlet pressure (bar absolute)

Page 9: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

9 Parker HannifinDenison Vane Pump DivisionVierzon - France

Cartridge Speed RPMSeries

Size Series 1200 1500 1800 2100 2200 2300 2500 2800 3000 3600

D

B14

0,80 0,80

0,80 0,80 0,80 0,80

0,80

0,80 0,80B14

B17 B17

B20 0,82 0,86 B20

B22 0,83 0,88 B22

B24 0,86 0,95 B24

B28 0,88 1,00 B28

B31 0,90 1,05 B31

B35 0,84 0,97 B35

B38 0,86 1,01 B38

B42 0,90 B42

0450,85

0,98 1,05 B45

050 1,02 1,09 B50

E

042

0,80 0,80

0,80 0,90

1,00

042

045 045

050 050

052 052

054 054

0570,85 0,95

057

062 062

0660,85 0,85

0,951,00

1,09 066

072 0,85 1,05 072

085 0,90 0,90 1,00 085

Inlet pressure is measured at inlet flange with petroleum base fluids at viscosity between 10 and 65 cSt. The difference between inlet pressure at the pump flange and atmospheric pressure must not exceed 0,2 bar to prevent aeration.Multiply absolute pressure by 1,25 for HF-3, HF-4 fluids. by 1,35 for HF-5 fluid. by 1,10 for ester or rapeseed base.For double and triple pumps, prefer the cartridge requiring the highest absolute pressure.

Minimumallowableinletpressure

Page 10: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

10 Parker HannifinDenison Vane Pump DivisionVierzon - France

To resolveVolumetric displ. .. Vi [ml/rev.]Available flow ....... qv [l/min]Input power .......... P [kW]

Routine :

1. First calculation Vi =

2. Choice Vi of pump immediately greater (see tabulation)

3. Theoretical flow of this pump Vp x n 1000

4. Find qvs leakage function of pressure q

Vs = f(p) on curve at 10 or 24 cSt

5. Available flow qVe

= qVi

- qVs

6. Theoretical input power q

Vi x p

600

7. Find Ps hydrodynamic power loss on curve

8. Calculation of necessary input power P = Pi + Ps

9. Results

Performances requiredRequested flow .... qv [l/min] 75Speed .................... n [RPM] 2500Pressure ................ p [bar] 250

Example :

Vi = = 30 ml/rev.

T7B B10, Vi = 31,8 cm3/rev.

qVi

= = 79,5 l/min

T7B (page 22) : qVs

= 3 l/min at 250 bar, 24 cSt

qVe

= 79,5 - 3 = 76,5 l/min

Pi = = 33,1 kW

T7B (page 14) : Ps at 2500 RPM, 250 bar = 0,9 kW

P = 33,1 + 0,9 = 34,0 kW

Vi = 31,8 ml/rev.q

Ve = 76,5 l/min T7B B10

P = 34,0 kW

1000 Q n

qVi

=

Pi =

1000 x 75 2500

31,8 x 2500 1000

79,5 x 250 600

These calculation steps must be followed for each application.

MAIN CALCULATION

INTERMITTENT PRESSURE RATING T7 and T67 units may be operated intermittently at pressures higher than the recommended continuous rating when the time weighted average of pressure is less than or equal to the continuous duty pressure rating. This intermittent pressure rating calculation is only valid when the other parameters : speed, fluid, viscosity and contamination level are respected.For total cycle time longer than 15 minutes, please consult your Parker Denison repre-sentative.

Example : T7B - B10Duty cycle ........... 4 min. at 320 bar.............................. 1 min. at 35 bar.............................. 5 min. at 160 bar

= 211,5 bar

211,5 bar is lower than 290 bar allowed as continuous pressure for T7B - B10 with HF-0 fluid.

(4 x 320) + (1 x 35) + (5 x 160) 10

Pumpselection

211,5

0

100

200

300

0 5 10

Time (minutes)

Pres

sure

(bar

) Average Pressure

Cycle

Page 11: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

11 Parker HannifinDenison Vane Pump DivisionVierzon - France

• The high pressure capability up to 320 bar, in the small envelope, reduces installation costs and provides extended life at reduced pressure.

• The high volumetric efficiency, reduces heat generation, and allows speeds down to 600 RPM at full pressure.

• The high mechanical efficiency, typically better than 94%, reduces energy consumption.

• The wide speed range (600 RPM at 3600 RPM), combined with large size cartridge displacements will optimize operation for the lowest noise level in the smallest envelope.

• The low speed (600 RPM), low pressure, high viscosity (860 cSt) allows application in cold environment with a minimum energy consumption and without risk of seizure.

• The low ripple pressure (± 2 bar) reduces piping noise and increases lifetime of the other components in the circuit.

• The high resistance to particle contamination, thanks to the double lip technology increasing the pump lifetime.

• The large variety of options (cam displacement, shaft, porting) allows customized installation.

• Noise : Specially designed to optimize the low noise level cha-racteristics.

• Cartridge concept : drops maintenance costs.

APPLICATION ADVANTAGES

B

B A

A

Front & rear sideplates are each clamped axialy by the separate

discharge pressures.

Pilot recess as required by SAE for full conformity.

Shaft end outlet port has 4-positions at 90° intervals

relative to inlet.

Cap end outlet port has8-positions at 45° intervals relative to inlet on each

double and triple pump.

Working vane on major arc pushes fluid to discharge port.

Inlet

Cartridge are replaceable assemblies. Each includes cam ring, rotor, vanes, pins and sideplates.

Holes in cam ring improve wide cartridge inlet characteristics.

Suction ramp where unloaded vane

moves out.

Working vane on minor arc seals discharge pressure from the suction

port.

Discharge ramp where unloaded vane moves in.

Pin cavity is at a steady pressure equal to that at

discharge port.

Side feed holes supply discharge pressure to pin cavities.

Vane is urged outward at suction ramp by pin force

and centrifugal force.

Cartridge is a replaceable assembly that includes :cam ring, rotor,

vanes, pins and plates.

Shaft comes in variety of keyed and splined options to meet SAE

and ISO 3019-1 standards.

Ball bearing holds the shaft in alignment.

90° Section

Section B-B

Section A-A

Inlet Outlet

Description

Page 12: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

12 Parker HannifinDenison Vane Pump DivisionVierzon - France

All Parker Denison vane pumps are individually tested to provide the best quality & reliability. Modifications, conversions & repairs can only be done by authorized dealers or OEM to avoid invalidation of the guaran-tee.

The pumps are to be used in the design limits indicated in all the sales bulletins. Please contact Parker Denison when tresspassing the catalogue limits.

Do not modify or work on the pump under pressure or when the electric motor (or any drive) is on.

Qualified personnel is required to assemble and set-up hydraulic devices.

Always conform yourself to the valid regulations (safety, electrical, environment...).

The following instructions are important to follow to obtain a good service life time from the unit.

The rotation and ports orientation are viewed from the shaft end.

CW stands for clockwise = right-hand rotation.

CCW stands for counter-clockwise = left-hand rotation.

The distance between the suction pipe & the return lines in the tank should be at its maximum.

A bevel on both suction & return lines is recommended to increase the surface and so lower the velocity. We suggest a 45° minimum angle.

Velocities : inlet 0,5 < x < 1,9 m/s (1,64 < x < 6,23 ft per sec.) : return x < 6 m/s (x < 19,7 ft per sec.) : Always insure that all return and suction lines are under the oil level to avoid forming aeration or vortex effect. This should be done under the most critical situation (all cylin- ders extended for example). Straight and short pipes are the best.

Q (Lpm) Q (GPM)

6 x p x r2 (cm) 3.12 x p x r2 (in)

The size of the air filter should be 3 times greater than the max. instant return flow (all cylinders in movement for example).

If the pump is in the tank, please choose the NOP option (no paint) and use a short inlet pipe.

Parker Denison does not recommend inlet strainers. If needed, a 100 mesh (149 microns) is the finest mesh recommended.

A coaxial drive is recommended. For any other type of drives, please contact Parker Denison.

Make sure that all protective plugs & covers have been removed.

Check the pump rotation versus the E-motor or engine rotation.

The tank has been filled up with a clean fluid in proper conditions.

We recommend to flush the system with an external pump prior to the start-up.

It is important to bleed the air off the circuit & the pump itself.

The first valve on the circuit should be open to tank.

We recommend the use of air bleed off valves.

It is possible to bleed off the air by creating a leak in the P port of the pump. Warning : this has to be done in a low pressure mode as it could create a dangerous fluid leak. Make sure that the pressure cannot rise (open center valve to tank, pressure relief valve unloaded ...).

GENERAL :

ROTATION & PORTS INDICATION

START-UP CHECk-UP Check that the assembly of the power unit is correct :

Start-up :

V = V = = m/s = ft/s

Start-upinstructions&recommendations

Page 13: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

1� Parker HannifinDenison Vane Pump DivisionVierzon - France

When oil free of air appears, tighten the connectors to the correct tor-que.

The pump should prime within a few seconds. If not, please consult our troubleshooting guide (document 1 - EN0721 - *).

If the pump is noisy, please troubleshoot the system.

Never operate the pump at top speed and pressure without checking the completion of pump priming.

• The mating female spline should be free to float and find its own center. If both members are rigidly supported, they must be aligned within 0,15 TIR (0.006” TIR) or less to reduce fretting. The angu-lar alignment of two splines axes must be less than ± 0,05 per 25,4 radius (± 0.002” per 1” radius).

• The coupling spline must be lubricated with a lithium molydisul-fide grease, disulfide of molybdenum or a similar lubricant.

• The coupling must be hardened to a hardness between 29 and 45 HRC.

• The female spline must be made to conform to the Class 1 fit as described in SAE-J498b (1971). This is described as a Flat Root Side Fit.

Parker Denison supplies the T7 series keyed shaft pumps with high strength heat-treated keys. Therefore, when installing or replacing these pumps, the heat-treated keys must be used in order to ensure maximum life in the application. If the key is replaced, it must be a heat-treated key between 27 and 34 R.C. hardness. The corners of the keys must be chamfered by 0,76 mm to 1,02 mm (0.03 to 0.04) at 45° to clear the radii in the key way.

The alignment of keyed shafts must be within tolerances given for splined shafts here above.

These products are primarily designed for coaxial drives which do not impose axial or side loading on the shaft. Contact Parker Denison for specific applications.

Please read the charts in the sales leaflets as the minimum requested inlet pressure varies versus the displacement and the speed. Never go under 0,8 bar Absolute (-0,2 bar relative) 11.6 PSI Absolute (-2.9 PSI G).

It is recommended to always have at least 1,5 bar (22 PSI) differential between inlet and outlet. Standard shaft seals are limited to 0,7 bar (10 PSI G) but some allow 7 bar (100 PSI G). Please contact Parker Denison for more information.

It is recommended to always have at least 1,5 bar (22 PSI) differential between inlet and outlet.

When assembled vertically, always be careful to prevent any air from being trapped in the pump (behind the shaft seal for example).

Type of fluids : For each type of fluids, Parker Denison’s vane pumps will have different pressures, speeds & temperature limits. Please refer to the sales leaflets. HF-0 = Anti-wear petroleum base. HF-1 = Non anti-wear petroleum base. HF-2 = Anti-wear petroleum base. HF-3 = Water-in-oil invert emulsions. HF-4 = Water glycol solutions. HF-5 = Synthetic fluids.

SHAFT & COUPLING DATA :

COUPLINGS AND FEMALE SPLINES

kEYED SHAFTS

SHAFT LOADS

SPECIFIC POINTS :

MINIMUM INLET PRESSURE

MAXIMUM INLET PRESSURE

MINIMUM OUTLET PRESSURE

VERTICAL MOUNT

FLUIDS :

DENISON CLASSIFICATION

Start-upinstructions&recommendations

Page 14: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

1� Parker HannifinDenison Vane Pump DivisionVierzon - France

NAS 1638 class 8 or better. ISO 19 / 17 / 14 or better. Inlet strainer : Parker Denison does not recommend inlet strainers. If requested, a 100 mesh (149 microns) is the finest mesh recommended.

Petroleum based antiwear R & O fluids. These fluids are the recommended fluids for pumps & motors. Maximum catalogue (UK version) ratings and performance datas are based on operation with these fluids. These fluids are covered by Parker Denison HF-0 and HF-2 specifications.

The use of fluids other than petroleum based antiwear R & O fluids requires that the maximum ratings of the pumps will be reduced. In some cases the minimum replenishment pressures must be increased. Consult specific sections for more details.

Indutrial Max. (cold start, low speed & pressure) 860 cSt - 3900 SUS Max. (full speed & pressure) 108 cSt - 500 SUS Optimum (max. life) 30 cSt - 140 SUS Min. (full speed & pressure for HF-1, HF-3, HF-4 & HF-5 fluids) 18 cSt - 90 SUS Min. (full speed & pressure for HF-0 & HF-2 fluids) 10 cSt - 60 SUS

90 min. Higher values extend the range of operating temperatures.

The usual limitating factor of temperature (low or high) comes from the obtained viscosity. The seals are sometimes the limit : standard seals range from -30° C to 90° C (-9.4° F to 194° F).

Maximum fluid temperature (q) ° C ° F HF-0, HF-1, HF-2 + 100 + 212 HF-3, HF-4 + 50 + 122 HF-5 + 70 + 158 Biodegradable fluids (esters & rapeseed base) + 65 + 149

Minimum fluid temperature (q) ° C ° F (also depend on max. viscosity) HF-0, HF-1, HF-2, HF-5 - 18 - 0.4 HF-3, HF-4 + 10 + 50 Biodegradable fluids (esters & rapeseed base) - 18 - 0.4

Over or under these values, please contact Parker Denison.

Maximum acceptable content of water : • 0,10 % for mineral base fluids. • 0,05 % for synthetic fluids, crankcase oils, biodegradable fluids. If the amount of water is higher, then it must be drained off the circuit.

pressure (bar) x displacement cm3/rev 20 p x mech. eff.

rpm x (cm3/rev) x pressure (bar) 600000 x overall eff.

rpm x (cm3/rev) x volumetric eff. 1000

1000 x flow rate (Lpm) x volumetric eff. displacement (cm3/rev.)

pressure (bar) x displacement (cm3/rev) x mech. eff. 20 p

rpm x (cm3/rev) x (bar) x overall eff. 600000

FILTRATION RECOMMENDATIONS

RECOMMENDED FLUIDS

ACCEPTABLE ALTERNATE FLUIDS

VISCOSITY

VISCOSITY INDEX

TEMPERATURES

WATER CONTAMINATION IN THE FLUID

FLUID POWER FORMULAS

Pump input torque N.m

Pump input power kW

Pump output flow Lpm

Fluid motor speed rpm

Fluid motor torque N.m

Fluid motor power kW

Start-upinstructions&recommendations

Page 15: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

1� Parker HannifinDenison Vane Pump DivisionVierzon - France

Mounting standardWeight withoutconnector andbracket - kg

Moment of inertia

Kgm2 x 10-4

SAE 4 bolts - J518 - 150/DIS6162-1Suction Pressure

S P1

T7ASSAE J744

ISO/3019-1 SAE A9,5 2,6

1"-SAE 4 boltsJ518-ISO/DIS 6162-1

3/4"-SAE 4 boltsJ518-ISO/DIS 6162-1

SAE 16-SAE threads1.5/16"-12 UNF-2B

SAE 12-SAE threads1.1/16"-12 UNF-2B

NPTF threads1.1/4" NPTF

NPTF threads3/4" NPTF

1" BSP 3/4" BSP

T7ASWSAE J744

ISO/3019-1 SAE A11,3 3,2

1.1/4"-SAE 4 boltsJ518-ISO/DIS 6162-1

3/4"-SAE 4 boltsJ518-ISO/DIS 6162-1

SAE 20-SAE threads1.5/8"-12 UNF-2B

SAE 12-SAE threads1.1/16"-12 UNF-2B

NPTF threads1.1/4" NPTF

SAE 12-SAE threads1.1/16"-12 UNF-2B

1.1/4" BSP 3/4" BSP

T7BISO/3019-2100 A2 HW

23,0 3,2 1.1/2" 1" or 3/4"T7BS

SAE J744SAE B

T6CSAE J744

SAE B15,7 7,5 1.1/2" 1"

T7DISO 3019-2125 A2 HW

26,0 19,6 2" 1.1/4"T7DS

SAE J744SAE C

T7EISO 3019-2125 A2 HW

43,3 62,5 3" 1.1/2"T7ES

SAE J744SAE C

S P1 P2

T7BBISO 3019-2100 A2 HW

32,6 6,7 2.1/2" 1" or 3/4" 3/4"T7BBS

SAE J744SAE B

T6CCSAE J744

SAE B26,0 16,9 2.1/2" or 3" 1" 1" or 3/4"

T67CBSAE J744

SAE B26,0 11,4 2.1/2" 1" 3/4"

T7DBISO 3019-2125 A2 HW

38,6 22,7 3" 1.1/4" 1" or 3/4"T7DBS

SAE J744SAE C

T67DCSAE J744

SAE C38,6 26,3 3" 1.1/4" 1" or 3/4"

T7DDSAE J744

SAE C56,0 36,3 4" 1.1/4" 1.1/4"

T7DDSISO 3019-2125 A2 HW

T7EBISO 3019-2125 A2 HW

55,0 65,9 3.1/2" 1.1/2" 3/4"T7EBS

SAE J744SAE C

T67ECSAE J744

SAE C55,0 70,8 3.1/2" 1.1/2" 1"

T7EDISO 3019-2125 A2 HW

66,0 79,7 4" 1.1/2" 1.1/4"T7EDS

SAE J744SAE C

T7EEISO 3019-2250 B4 HW

95,0 97,4 4" 1.1/2" 1.1/2"T7EES

SAE J744SAE E

Generalcharacteristics

Page 16: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

1� Parker HannifinDenison Vane Pump DivisionVierzon - France

Mounting standardWeight withoutconnector andbracket - kg

Moment of inertia

Kgm2 x 10-4

SAE 4 bolts - J518 - 150/DIS6162-1

Suction Pressure

S P1 P2 P3

T7DBBISO/3019-2 125 A2 HW

61,0

26,1

4" 1.1/4" 1" 1" or 3/4"

T7DBBSSAE J744

SAE C

T7DCBISO/3019-2 125 A2 HW

29,7T7DCBS

SAE J744 SAE C

T7DCCISO/3019-2 125 A2 HW

33,3T7DCCS

SAE J744 SAE C

T7DDBISO 3019-2125 B4 HW

66,0 39,5 4" 1.1/4" 1.1/4" 1" or 3/4"T7DDBS

SAE J744SAE C

T67DDCSSAE J744

SAE C66,0 43,1 4" 1.1/4" 1.1/4" 1" or 3/4"

T7EDBISO 3019-2250 B4 HW

102,0 76,6 4" 1.1/2" 1.1/4" 1" or 3/4"T7EDBS

SAE J744SAE E

T67EDCISO 3019-2250 B4 HW

102,0 80,2 4" 1.1/2" 1.1/4" 1" or 3/4"T67EDCS

SAE J744SAE E

T7EECISO/3019-2 250 B4 HW

114,8 99,1 4" 1.1/2" 1.1/2" 1" or 3/4"T7EECS

SAE J744 SAE E

Generalcharacteristics

Page 17: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

1� Parker HannifinDenison Vane Pump DivisionVierzon - France

notes

Page 18: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

18 ParkerHannifinDenison Vane Pump DivisionVierzon - France

T7AS-OrderingCode

Model No. T7AS - B17 - 1 R 00 - A 1 - 00 - ..

T7AS series - SAE A 2 boltsJ744 mounting flange

Displacement *Volumetric displacement (ml/rev.)B06 = 5,8B10 = 9,8B11 = 11,0B13 = 12,8B17 = 17,2B20 = 19,8B22 = 22,5B25 = 24,9

Type of shaft T7AS1 = keyed (non SAE) Ø 19,053 = splined 16/32 (SAE B) 13 teeth4 = splined 16/32 (SAE A) 9 teeth

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

Modifications

Mounting w/connection variables00 = 4 bolts SAE flanges (J518) UNC thread S = 1” SAE P = 3/4” SAE02 = SAE thread S = 1.5/16” (SAE 16) P = 1.1/16” (SAE 12)03 = NPTF thread S = 1.1/4” NPTF P = 3/4” NPTF04 = BSP threads S = 1” BSP P = 3/4” BSP

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)5 = S5 VITON® - 0,7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination00 = standard

P = PressureS = Suction

S SS S

P

P

P P

00 01 02 03

Noise level (typical) - t7as - b20iNteRNal leaKaGe (typical)

peRmissible Radial loadpoweR loss hydRomechaNical (typical)

50

52

54

56

58

60

62

64

66

0 50 100 150 200 250 300

n = 1000 RPM n = 1500 RPM

ν = 32 cStLw = Lp + 8 db(A)

Pe = 0,9 bar abs

100

300

500

700

900

1100

600 1200 1800 2400 3000 3600

0

1

2

3

4

5

6

7

8

0 60 120 180 240 300

24 cSt10 cSt

0

0,2

0,4

0,6

0,8

1

1,2

0 60 120 180 240 300

n = 1000 RPMn = 1500 RPM [24 cSt]

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]Maximum permissible axial load Fa = 600 N* Cartridge designation is now in ml/rev. (example : B22 = 22,5 ml/rev.)

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

FaF

==

Shaft keyed N°1

Page 19: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

19 ParkerHannifinDenison Vane Pump DivisionVierzon - France

P S

60,5 65

110

110

53

106

130,4

Ø 11

Ø 95,3

68(T

HR

EA

DE

D P

OR

TC

ON

NE

CTI

ON

)

63,5

6,4

7,438,278,1

138,5 44,4

25,4

Ø 8

2,55

0 -0.0

5

Ø 1

9,05

0 -0.0

25

21,1

4M

AX

KEY 4,775 4,724

Ø 4

7

1,5 x 45°

0,8 x 45°

MOUNTING TORQUE : 110 Nm

SHAFT CODE 1Keyed (non SAE)

SHAFT CODE 4SAE A splined shaft

Class 1 - J49816/32 d.p. - 9 teeth30° pressure angle

flat root side fit

11,2

SUCTION Ø A

26,2

52,4

3/8"-16UNC-2B x 19 DEEP - 4 HOLES

22,3

47,6

PRESSURE Ø B

39,4

SAE B splined shaftClass 1 - J498

16/32 d.p. - 13 teeth30° pressure angle

flat root side fit

3/8"-16UNC-2B x 17 DEEP - 4 HOLES

(TH

RE

AD

ED

PO

RT

CO

NN

EC

TIO

N)

C.G.

64

1,5 x 45°

19,1

6,4

7,4

SHAFT CODE 3

Option : built in valve

Code 00 02 03 04

A Ø 25,40SAE # 16

1.5/16’’ - 12 UNF - 2B1.1/14’’ NPTF 1’’ BSP

B Ø 19,05SAE # 12

1.1/16’’ - 12 UNF - 2B3/4’’ NPTF 3/4’’ BSP

Shaft torque limits [ml/rev. x bar]

Vi x p max.

8720

8720

6550

Shaft

1

3

4

If inlet velocity > 1,9 m/s, please contact Parker Denison. !

opeRatiNG chaRacteRistics - typical [24 cst]

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 300 bar p = 7 bar p = 140 bar p = 300 bar

T7AS

B06 5,8 ml/rev 8,7 7,0 5,2 0,2 2,7 6,0

B10 9,8 ml/rev 14,7 13,0 11,2 0,3 4,1 9,0

B11 11,0 ml/rev 16,5 14,8 13,0 0,4 4,5 9,9

B13 12,8 ml/rev 19,2 17,5 15,7 0,4 5,1 11,3

B17 17,2 ml/rev 25,8 24,1 22,3 0,5 6,6 14,6

B20 19,8 ml/rev 29,7 28,0 26,2 0,6 7,6 16,5

B22 22,5 ml/rev 33,8 32,1 30,2 0,6 8,5 18,6

B25 24,9 ml/rev 37,4 35,7 33,8 0,7 9,3 20,4

T7AS-Dimensions-Weight:9,5kg

Page 20: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

20 ParkerHannifinDenison Vane Pump DivisionVierzon - France

Model No. T7ASW - B32 - 1 R 00 - A 1 - 00 - ..

T7ASW series - SAE A 2 boltsJ744 mounting flange

Displacement *Volumetric displacement (ml/rev.)B26 = 26,0B28 = 28,0B30 = 30,0B32 = 31,8B34 = 34,0B36 = 36,0B40 = 40,0

Type of shaft T7ASW1 = keyed (non SAE) Ø 19,053 = splined 16/32 (SAE B) 13 teeth4 = splined 16/32 (non SAE) 11 teeth

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

Modifications

Mounting w/connection variables00 = 4 bolts SAE flanges (J518) UNC threads S = 1.1/4” SAE P = 3/4” SAE02 = SAE thread S = 1.5/8” (SAE 20) P = 1.1/16” (SAE 12)03 = NPTF & SAE threads S = 1.1/4” NPTF P = 1.1/16” (SAE 12)04 = BSP threads S = 1.1/4” BSP P = 3/4” BSP

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)

Design letter

Porting combination00 = standard

P = PressureS = Suction

S SS S

P

P

P P

00 01 02 03

Noise level (typical) - t7asW b28iNteRNal leaKaGe (typical)

peRmissible Radial loadpoWeR loss hydRomechaNical (typical)

57

59

61

63

65

67

69

71

73

0 50 100 150 200 250 300

n = 1000 RPMn = 1500 RPMν = 32 cStLw = Lp + 8 db(A)

Pe = 0,9 bar abs

100

300

500

700

900

1100

600 1200 1800 2400 3000 3600

0

1

2

3

4

5

6

7

8

0 60 120 180 240 300

24 cSt10 cSt

0

0,2

0,4

0,6

0,8

1

1,2

0 60 120 180 240 300

n = 1000 RPM

n = 1500 RPM [24 cSt]

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]Maximum permissible axial load Fa = 800 N* Cartridge designation is now in ml/rev. (example : B22 = 22,5 ml/rev.)

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

T7ASW-OrderingCode

FaF

==

Shaft keyed N°1

Page 21: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

21 ParkerHannifinDenison Vane Pump DivisionVierzon - France

Code 00 02 03 04

A Ø 31,80SAE # 20

1.5/16’’ - 12 UNF - 2B1.1/14’’ NPTF 1”1/4 BSP

B Ø 19,05SAE # 12

1.1/16’’ - 12 UNF - 2BSAE # 12

1.1/16’’ - 12 UNF - 2B3/4 ” BSP

Ø 95,3

60,5 65

110

110

Ø 11

53

106

130,4

6,4

7,4

38,299,7

160,8 44

Ø 5

2,02

82,5

82,

5

Ø 1

9,05

0 -0.0

25

25,4

21,1

2M

AXI

SHAFT CODE 1(KEYED NO SAE)

1,5 x 45°

0,8 x 45°

KEY 4,775 / 4,724

63,568

(TH

RE

AD

ED

PO

RT

CO

NN

EC

TIO

N)

(TH

RE

AD

ED

PO

RT

CO

NN

EC

TIO

N)

MOUNTING TORQUE : 110 Nm

58,7

30,222,3

47,6

11,2

SHAFT CODE 3SAE-B splined shaft

Class 1 - J498b16/32 d.p. - 13 teeth30° pressure angle

flat root side fit

1,5 x 45°

24,5

40

7,4

SUCTION Ø APRESSURE Ø B

7/16"-14UNC-2B x 22 DEEP - 4 HOLES

3/8"-16UNC-2B x 17 DEEP - 4 HOLES

7,4

37

19

1,5 x 45°

SHAFT CODE 4Splined shaft

Class 1 - J498b16/32 d.p. - 11 teeth30° pressure angle

flat root side fit

74,6

Shaft torque limits [ml/rev. x bar]

Vi x p max.

18530

18530

12660

Shaft

1

3

4

If inlet velocity > 1,9 m/s, please contact Parker Denison.!

opeRatiNG chaRacteRistics - typical [24 cst]

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 300 bar p = 7 bar p = 140 bar p = 300 bar

T7ASW

B26 26,0 ml/rev 39,0 37,3 35,5 0,8 9,5 20,6

B28 28,0 ml/rev 42,0 40,3 38,5 0,9 10,2 22,1

B30 30,0 ml/rev 45,0 43,3 41,5 0,9 10,9 23,6

B32 31,8 ml/rev 47,7 46,0 44,2 0,9 11,6 25,0

B34 34,0 ml/rev 51,0 49,3 47,5 1,0 12,3 26,6

B36 36,0 ml/rev 54,0 52,3 50,5 1,0 13,0 28,1

B40 40,0 ml/rev 60,0 58,3 56,5 1,1 14,4 31,1

T7ASW-Dimensions-Weight:11,3kg

Page 22: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

22 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T7B or T7BS - B10 - 1 R 00 - A 1 - M0 - ..

T7B series - 100 A2 HWISO 2 bolts 3019-2 mounting flangeT7BS series - SAE B 2 boltsJ744 mounting flange

DisplacementVolumetric displacement (ml/rev.)B02 = 5,8 B07 = 22,5 B11 = 35,0B03 = 9,8 B08 = 24,9 B12 = 41,0B04 = 12,8 B09 = 28,0 B14 = 45,0B05 = 15,9 B10 = 31,8 B15 = 50,0B06 = 19,8

Type of shaft T7B - T7BS2 = keyed (ISO R775)

Type of shaft T7BS1 = keyed (SAE B) Ø 22,23 = splined (SAE B) 13 teeth4 = splined (SAE BB) 15 teeth

Modifications

Mounting w/connection variables4 bolts SAE flange J518

T7B-T7BS T7BSMetric thread UNC thread

M0 M1 00 01

P 1" 3/4" 1" 3/4"S 1.1/2"

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 0,7 bar max. (for fire resistant fluids)5 = S5 VITON® - 0,7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination00 = standard

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

P = Pressure portS = Suction port

Noiselevel(TypiCal)-T7B-B10iNTeRNalleaKaGe(TypiCal)

peRmissiBleRadialloadpoweRlosshydRomeChaNiCal(TypiCal)

50

55

60

65

70

0 40 80 120 160 200 240 280 320

Série1Série2

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

200

400

600

800

1000

1200

1400

600 1200 1800 2400 3000 3600

Shaftkeyedn°1

0

1

2

3

4

5

6

7

8

0 40 80 120 160 200 240 280 320

24 cSt10 cSt

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 800 N

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

T7B/T7Bs-orderingCode

P P P P

S

S

S

00 01 02 03

0

0,2

0,4

0,6

0,8

1

1,2

1,4

0 40 80 120 160 200 240 280 320

n = 1000 RPMn = 1500 RPM [24 cSt]

FaF

==

Shaft keyed N°1

Page 23: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

23 Parker HannifinDenison Vane Pump DivisionVierzon - France

T7B/Bs-dimensions-weight:23,0kg

Model T7B T7BSCode M0 M1 00 01Ø A M10 x 19 deep 3/8"-16 UNC x 19 deep

Ø B M12 x 22,4 deep 1/2"-13 UNC x 22,4 deep

C 26,20 22,25 26,20 22,25

D 52,4 47,65 52,4 47,65

Ø E 25,4 19,1 25,4 19,1

F 140 146

G 70 73

Ø H 14,0 14,3

174,5F

G

Ø H

168,5 71,682,3 38,1

7,96,35 MAXI

101,

6010

1,55

Ø

51,3

Ø

24,9

4M

AX

I

22,2

2522

,200

Ø

1,5 x 45°

9,7

1,3 x 45° Shaft code 1

(KEYED SAE "B")

Mounting torque : 187 Nm

40,77,9

T7BS SERIES (FLANGE SAE "B")

24,5

1,5 x 45°

76,2

45,67,9

24,5

1,5 x 45°

100,

000

Ø 9

9,96

7

28,2

2M

AXI

25,0

650

Ø 2

4,99

35

40,0

2,0 x 45°

9,0

1,5 x 45°

D70,0

35,0

35,817,9

C

12,7 70,0

10

KEY 8 x 7

SUCTION Ø

S P

Shaft code 2 (KEYED ISO R775)

Ø A 4-HOLES

T7B SERIES (FLANGE ISO 3019/2 100A 2HW )

Shaft code 4 Shaft code 3SAE B INVOLUTE SPLINE DATACLASS 1 - FLAT ROOT SIDE FITJ498b - PITCH 16/3213 TEETH - 30° PRESSURE ANGLE

Ø B 4-HOLES

SAE BB INVOLUTE SPLINE DATACLASS 1 - FLAT ROOT SIDE FITJ498b - PITCH 16/3215 TEETH - 30° PRESSURE ANGLE

38,1 PRESSURE Ø E

120,6

C.G.

Shaft torque limits [ml/rev. x bar]Shaft Vi x p max.

1 16500

2 20600

3 20600

4 20600

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 320 bar p = 7 bar p = 140 abr p = 320 bar

T7BT7BS

B02 5,8 ml/rev 8,7 7,0 4,8 0,5 2,6 5,4

B03 9,8 ml/rev 14,7 13,0 10,8 0,6 4,0 8,6

B04 12,8 ml/rev 19,2 17,5 15,3 0,6 5,0 11,0

B05 15,9 ml/rev 23,9 22,2 20,0 0,7 6,1 13,5

B06 19,8 ml/rev 29,7 28,0 25,8 0,7 7,5 16,6

B07 22,5 ml/rev 33,7 32,0 29,9 0,8 8,5 18,8

B08 24,9 ml/rev 37,4 35,7 33,5 0,8 9,3 20,7

B09 28,0 ml/rev 42,0 40,3 38,1 0,9 10,4 23,2

B10 31,8 ml/rev 47,7 46,0 43,8 0,9 11,7 26,2

B11 35,0 ml/rev 52,5 50,8 48,91) 1,0 12,8 27,01)

B12 41,0 ml/rev 61,5 59,8 57,91) 1,1 14,9 31,51)

B14 45,0 ml/rev 67,5 65,8 63,91) 1,2 16,3 34,51)

B15 50,0 ml/rev 75,0 73,3 71,62) 1,3 18,1 35,72)

1) B11 - B12 - B14 = 300 bar max. int. 2) B15 = 280 bar max. int.

opeRaTiNGChaRaCTeRisTiCs-TypiCal[24cst]

Page 24: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

24 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T6C* - 022 - 1 R 00 - B 1 - ..

Series - SAE B 2 boltsJ744 mounting flange* Rear drive option available, please contact Parker Denison

DisplacementVolumetric displacement (ml/rev.)003 = 10,8 017 = 58,3005 = 17,2 020 = 63,8006 = 21,3 022 = 70,3008 = 26,4 025 = 79,3010 = 34,1 028 = 88,8012 = 37,1 031 = 100,0014 = 46,0

Type of shaft1 = keyed (SAE B) Ø 22,22 = keyed (non SAE)3 = splined (SAE B) 13 teeth4 = splined (SAE BB) 15 teeth

Modifications

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON® - 7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination00 = standard

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

P = Pressure portS = Suction port

Noiselevel(TypiCal)-T6C-022iNTeRNalleaKaGe(TypiCal)

peRmissibleRadialloadpoweRlosshydRomeChaNiCal(TypiCal)

55

60

65

70

75

0 40 80 120 160 200 240

Série1

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMu = 32 cStLw = Lp + 8 db (A)

200

400

600

800

1000

1200

1400

600 1000 1400 1800 2200 2600

Shaftkeyedn°1

0

3

6

9

12

15

18

21

0 35 70 105 140 175 210 245 280

24 cSt10 cSt

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 800 N

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

FaF

==

Shaft keyed N°1

u

T6C-orderingCode

P P P P

S

S

S

00 01 02 03

0

0,5

1

1,5

2

2,5

3

3,5

0 40 80 120 160 200 240 280

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2800 RPM

Page 25: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

25 Parker HannifinDenison Vane Pump DivisionVierzon - France

T6C-dimensions-weight:15,7kg

KEY 6.35 6.30

S P

KEY 4,762 4,712

1/2” - 13UNC x 22,4 DEEP-4 HOLES 2)

3/8” - 16UNC x 19 DEEP-4 HOLES 2)

SHAFT CODE 1 (Keyed SAE B)

SHAFT CODE 2 SHAFT CODE 3

SAE B INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 16/32 13 TEETH - 30° PRESSURE ANGLE

SHAFT CODE 4 SAE BB INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 16/32 15 TEETH - 30° PRESSURE ANGLE

174,5

146,0

73,0

Ø 14,313

5,0

76,2

161,6

82,3 38,19,77,9

6,35 MAXI

71,4

38,1

1,3 x 45°

1,5 x 45°

101,

6010

1,55

Ø

51,3

Ø

M8

16 D

EE

P

22,2

2522

,200

Ø 24,9

4M

AX

I

70,0

35,0

52,4

26,2

35,8

17,926,2

13,1

12,7

7,9

58,2

31,7

1,5 x 45°

22,2

2522

,200

Ø

24,5

3M

AX

I

Ø 25,4PRESSUREØ 38,1SUCTION

45,57,9

24,5

1,5 x 45°

40,7

7,9

24,5

1,5 x 45°

(Keyed non SAE )

Mounting torque : 159 Nm.

C.G.

75,7

Shaft torque limits [ml/rev. x bar]Shaft Vi x p max.

1 16340

2 14300

3 20600

4 21800

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 240 bar p = 7 bar p = 140 bar p = 240 bar

T6C

003 10,8 ml/rev 16,2 11,2 7,7 1,3 5,3 8,4

005 17,2 ml/rev 25,8 20,8 17,3 1,4 7,5 12,2

006 21,3 ml/rev 31,9 26,9 23,4 1,5 8,9 14,7

008 26,4 ml/rev 39,6 34,6 31,1 1,6 10,7 17,7

010 34,1 ml/rev 51,1 46,1 42,6 1,7 13,4 22,3

012 37,1 ml/rev 55,6 50,6 47,1 1,7 14,4 24,1

014 46,0 ml/rev 69,0 64,0 60,5 1,9 17,6 29,5

017 58,3 ml/rev 87,4 82,4 78,9 2,1 21,9 36,9

020 63,8 ml/rev 95,7 90,7 87,2 2,2 23,8 40,2

022 70,3 ml/rev 105,4 100,4 96,9 2,3 26,1 44,1

025 79,3 ml/rev 118,9 113,9 110,4 2,5 29,2 49,5

028 88,8 ml/rev 133,2 128,2 125,81) 2,8 32,7 48,51)

031 100,0 ml/rev 150,0 145,0 142,61) 2,8 36,5 54,41)

1) 028 - 031 = 210 bar max. int. 2) Port connection can be supplied with metric threads (Please contact Parker Denison).

opeRaTiNGChaRaCTeRisTiCs-TypiCal[24cst]

Page 26: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

26 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T7D* or T7DS - B42 - 1 R 00 - A 1 - M0 - ..

T7D series - 125 A2 HWISO 2 bolts 3019-2 mounting flangeT7DS series - SAE C 2 boltsJ744 mounting flange* Rear drive option available, please contact Parker Denison

DisplacementVolumetric displacement (ml/rev.)B14 = 44,0 B31 = 99,2B17 = 55,0 B35 = 113,4B20 = 66,0 B38 = 120,6B22 = 70,3 B42 = 137,5B24 = 81,1 045 = 145,7B28 = 90,0 050 = 158,0

Type of shaft T7D - T7DS5 = keyed (ISO 3019-2 - G32M)

Type of shaft T7DS1 = keyed (SAE C) Ø 31,72 = keyed (non SAE)3 = splined (SAE C) 14 teeth4 = splined (non SAE)

Modifications

Mounting w/connection variables4 bolts SAE flange J518

P = 1.1/4" - S = 2"Metric thread UNC thread

T7D M0T7DS M0 Y01) 00

1) 250 bar max. int.

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON® - 7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination00 = standard

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

P = Pressure portS = Suction port

Noiselevel(TypiCal)-T7D-B31iNTeRNalleaKaGe(TypiCal)

peRmissiBleRaDialloaDpoweRlosshyDRomeChaNiCal(TypiCal)

55

60

65

70

75

0 40 80 120 160 200 240 280

Série1

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

200

400

600

800

1000

1200

1400

1600

1800

600 900 1200 1500 1800 2100 2400

Shaft keyedn°1

0

3

6

9

12

15

18

21

24

27

30

0 50 100 150 200 250 300

24 cSt10 cSt

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 1200 N

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

T7D/T7Ds-orderingCode

P P P P

S

S

S

00 01 02 03

0

0,5

1

1,5

2

2,5

3

3,5

0 50 100 150 200 250 300

n = 1000 RPM

n = 1500 RPM [24 cSt]

FaF

==

Shaft keyed N°1

Page 27: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

27 Parker HannifinDenison Vane Pump DivisionVierzon - France

T7D/Ds-Dimensions-weight:26,0kg

Model T7D T7DSCode M0 00 M0 YO1)

Ø A M12 1/2" - 13 UNC M12 M12

Ø B M12 7/16" - 14 UNC M12 M10

C 180,0 181,0

D 90,0 90,5

Ø E 18,0 17,5

ØE

212,4

CD

156,

7 82,6

184,9 83,687,4 38,1 12,7

7,96,35 MA XI

127,

0012

6,95

Ø

64,3

Ø35

,3M

AX

I

31,7

531

,70

Ø

2,3 x 45°

SHAFT CODE 1 (Key ed SAE C)

M10 x 20 DEEP

KEY 7,94 7,89

MOUNTING TORQUE : 187 Nm77,7 (*)

7,948,0

2,3 x 45°

55,27,9

38,0

2,3 x 45°

49,3

SHAFT CODE 3SAE C INVOLUTE SPLINE DATACLASS 1-FLAT ROOT SIDE FIT

J498 b - PITCH 12/2414 TEETH- 30° PRESSURE ANGLE

SHAFT CODE 4SA E C S pc (* ) I NVOL UT E SPLI NE D ATA

CL A SS 1 -FLAT ROOT SIDE FITJ498 b - PI TCH 12/24

14 TEETH - 30 ° PR ES S URE A N G L E

T7DS

2,3 x 45°

35,3

MAX

I

31,7

531

,70

Ø

38,1

73,2

KEY 7,94 7 ,89

SHAFT CODE 2

15,7

PS 58,7 29

,35

77,8

38,9

30,215,1

42,921,45

Ø 31,8PRESSUREØ 50,8 *SU CTION

Ø B x 22 ,3 DEEPØ A x 23,9 DEEP

T7D

6,35 MAXI

SHAFT CODE 5 (ISO 3019/2- G32 M)

50,0

32,0

1832

,002

Ø 35,3

MA

XI

64,3

Ø

2,3 x 45°

KE Y 10 x 8

M10 x 20 DEEP

87,4

125,

000

124,

937

Ø

9,0147,4

7,9

7,9

(Keyed non SAE)

C.G.

76,2

Shaft torque limits [ml/rev. x bar]Shaft Vi x p max.

1 43240

2 34590

3 61200

4 61200

5 44300

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 300 bar p = 7 bar p = 140 bar p = 300 bar

T7DT7DS

B14 44,0 ml/rev 66,0 59,4 51,9 1,5 16,6 34,2

B17 55,0 ml/rev 82,5 75,9 68,4 1,7 20,4 42,4

B20 66,0 ml/rev 99,0 92,4 84,9 1,9 24,3 50,7

B22 70,3 ml/rev 105,5 98,8 91,3 2,0 25,8 53,9

B24 81,1 ml/rev 121,7 115,0 107,5 2,2 29,5 62,0

B28 90,0 ml/rev 135,0 128,4 120,9 2,3 32,7 68,7

B31 99,2 ml/rev 148,8 142,2 134,7 2,5 35,9 75,6

B35 113,4 ml/rev 170,1 163,5 156,91) 2,7 40,8 80,51)

B38 120,6 ml/rev 180,9 174,3 167,71) 2,9 43,4 85,61)

B42 137,5 ml/rev 206,3 199,6 194,02) 3,2 49,3 90,52)

045 145,7 ml/rev 218,6 209,2 202,63) 4,1 52,8 89,53)

050 158,0 ml/rev 237,0 227,7 223,04) 4,4 57,1 85,04)

1) B35 - B38 = 280 bar max. int. 2) B42 = 260 bar max. int. 3) 045 = 240 bar max. int. 4) 050 = 210 bar max. int.* special 2.1/2" (Ø 63,5) suction also available - Please contact Parker Denison

opeRaTiNGChaRaCTeRisTiCs-TypiCal[24cst]

1) 250 bar max. int.

Page 28: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

28 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T7E* or T7ES - 072 - 1 R 00 - A 1 - M0 - ..

T7E series - 125 A2 HWISO 2 bolts 3019-2 mounting flangeT7ES series - SAE C 2 boltsJ744 mounting flange* Rear drive option available, please contact Parker Denison.

DisplacementVolumetric displacement (ml/rev.)042 = 132,3 057 = 183,3045 = 142,4 062 = 196,7050 = 158,5 066 = 213,3052 = 164,8 072 = 227,1054 = 171,0 085 = 268,7

Type of shaft T7E - T7ES5 = keyed (ISO R775 - G38M)

Type of shaft T7ES1 = keyed (SAE CC)2 = keyed (non SAE)3 = splined (SAE C) 14 teeth4 = splined (SAE CC) 17 teeth

Modifications

Mounting w/connection variables4 bolts SAE flange J518

T7E - T7ES Metric thread

T7ESUNC thread

M0 00P 1.1/2"S 3"

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON® - 7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination00 = standard

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

P = Pressure portS = Suction port

Noiselevel(TypiCal)-T7es-050iNTeRNalleaKaGe(TypiCal)

peRmissibleRadialloadpoweRlosshydRomeChaNiCal(TypiCal)

60

65

70

75

80

0 40 80 120 160 200 240

Série1

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

400

800

1200

1600

2000

2400

2800

3200

600 1000 1400 1800 2200

Shaftkeyed

0369

1215182124273033

0 30 60 90 120 150 180 210 240

24 cSt10 cSt

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 2000 N

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

T7e/T7es-orderingCode

P P P P

S

S

S

00 01 02 03

0

1

2

3

4

5

6

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2200 RPM

FaF

==

Shaft keyed N°1

Page 29: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

29 Parker HannifinDenison Vane Pump DivisionVierzon - France

T7e/es-dimensions-weight:43,3kg

Alternate mounting flange

Dia Se x 45° W K Dia d

Max. Min.

T7E 125,000 124,937 2,0 9,5 180,0 18,0

T7ES 127,000 126,950 1,3 12,7 181,0 17,5

213,0K

K/2 147.60Ø

Ø d

187,

598

,6

225,3 90,9110,0 52,3 W

7,96,35 MAXI

50,8

Ø S76

,2Ø

42,3

6M

AXI

38,1

038

,05

Ø

2,3 x 45°

KEY 9,52 9,47

M10 x 20 DEEP

SHAFT CODE 1 ( Keyed SAE C-C )

MOUNTING TORQUE 187 Nm

SHAFT CODE 2

17,5

35,717,8

69,8 PS10

6,4

53,2

61,931,0

Ø 75,00 *SUCTION Ø 37,10PRESSURE

5/8”- 11 UNC x 24 DEEP - 4 HOLESM16 x 24 DEEP (METRIC VERSION)

55,9

7,9

38,0

62,2

7,9

31,5

2,3 x 45°

2,3 x 45°

SHAFT CODE 3 SAE C INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 12/24 14 TEETH - 30° PRESSURE ANGLE

SHAFT CODE 4 SAE CC INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 12/24

17 TEETH - 30° PRESSURE ANGLE

2,3 x 45°

38,1

61,9

KEY 7.947.89

31,7

531

,70

Ø 35,2

7M

AX

( Keyed no SAE )

1/2”- 13 UNC x 23,4 DEEP - 4 HOLESM12 x 23,4 DEEP (METRIC VERSION)

T7ES

T7E

2,3 x 45°

34,9

10,090,0

50,0

41,3

MAX

I

Ø S

38,0

1838

,002

Ø

KEY 10 x 8

M10 x 20 DEEP

W

SHAFT CODE 5 ( Keyed ISO/R775 - G38M)

C.G.

101,8

e x 45°

e x 45°

Shaft torque limits [ml/rev. x bar]Shaft Vi x p max.

1 54500

2 34590

3 61200

4 61200

5 54500

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 240 bar p = 7 bar p = 140 bar p = 240 bar

T7ET7ES

042 132,3 ml/rev 198,5 188,5 181,3 5,2 49,4 82,6

045 142,4 ml/rev 213,6 203,6 196,5 5,4 52,9 88,7

050 158,5 ml/rev 237,7 227,7 220,6 5,7 58,5 98,3

052 164,8 ml/rev 247,2 237,2 230,1 5,8 60,8 102,1

054 171,0 ml/rev 256,5 246,5 239,4 5,9 63,0 105,8

057 183,3 ml/rev 275,0 265,0 257,9 6,1 67,3 113,2

062 196,7 ml/rev 295,0 285,0 277,9 6,4 71,9 121,3

066 213,3 ml/rev 319,9 309,0 302,8 6,7 77,7 131,2

072 227,1 ml/rev 340,6 330,6 323,5 6,9 82,6 139,5

085 268,7 ml/rev 403,0 392,01) - 9,1 65,81) -1) 085 = 90 bar max. int.* special 3"1/2 (Ø 88,9) suction also available - Please contact Parker Denison

opeRaTiNGChaRaCTeRisTiCs-TypiCal[24cst]

Page 30: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

30 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T7BB or T7BBS - B10 - B10 - 1 R 00 - A 1 - M1 - ..

T7BB series - 100 A2 HWISO 2 bolts 3019-2 mounting flangeT7BBS series - SAE B 2 boltsJ744 mounting flange

Displacement P1 & P2Volumetric displacement (ml/rev.)B02 = 5,8 B09 = 28,0B03 = 9,8 B10 = 31,8B04 = 12,8 B11 = 35,0B05 = 15,9 B12 = 41,0B06 = 19,8 B14 = 45,0B07 = 22,5 B15 = 50,0B08 = 24,9

Type of shaft T7BB - T7BBS5 = keyed (ISO R775)

Type of shaft T7BBS1 = keyed (non SAE)2 = keyed (SAE BB)3 = splined (SAE B) 13 teeth4 = splined (SAE BB) 15 teeth

Modifications

Mounting w/connection variables4 bolts SAE flange J518

T7BB- T7BBS Metric thread

T7BBSUNC thread

M0 M1 00 01P1 1" 3/4" 1" 3/4"P2 3/4"S 2.1/2"

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 0,7 bar max. (for fire resistant fluids)5 = S5 VITON® - 0,7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination (see page 72)00 = standard

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

Noiselevel(TypiCal)-T7BB-B10-B04iNTeRNalleaKaGe(TypiCal)

peRmissiBleRadialloadpoweRlosshydRomeChaNiCal(TypiCal)

55

60

65

70

0 40 80 120 160 200 240 280 320

Série1

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

200

400

600

800

1000

1200

1400

600 1000 1400 1800 2200 2600

Shaftkeyed n°1

0

1

2

3

4

5

6

7

8

0 40 80 120 160 200 240 280 320

24 cSt10 cSt

P1-P2

P1-P2

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 800 NTotal hydromechanical power loss is the sum of each section loss under its respective operating conditions.

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss under its respective operating conditions.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

Double pump noise level is given with both stages discharging at the pressure value indicated on the curve.

T7BB/T7BBs-orderingCode

0

0,5

1

1,5

2

2,5

0 50 100 150 200 250 300

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2800 RPM

P1-P2

P1-P2

P1-P2

P1 P2

FaF

==

Shaft keyed N°1

Page 31: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

31 Parker HannifinDenison Vane Pump DivisionVierzon - France

T7BB/BBs-dimensions-weight:32,6kg

84,1

74,0

M

S P1

MM

Ø H

174,

5

F

G

22,2

47,6

50,825,4

88,9

44,5

D

C

12,7 70,010,0

40,0

100,

000

99,9

67Ø

1,5 x 45°

25,0

065

24,9

935

Ø 28,2

MAX

I

2,0 x 45°

9,0

PRESSURE Ø19

PRESSURE Ø ESUCTION Ø 63.5

Ø A 4-HOLES

Ø B 4-HOLES Ø A 4-HOLES

KEY 8 x 7

74,7

38,1101,698,6

262,4 58,2

7,96,4 MAXI 31,7

101,

6010

1,55

Ø

51,3

Ø

22,2

2522

,200

Ø

1,5 x 45°

1,3 x 45°

9,7

MOUNTING TORQUE : 187 NmMOUNTING TORQUE : 61 Nm

24,5

3M

AXI

71,47,9

38,1

25,4

025

,37

Ø1,5 x 45°

28,2

2M

AXI

40,77,9

24,51,5 x 45°

45,67,9

24,51,5 x 45°

KEY 4,762 4,712

M8 x 16 DEEP

KEY 6,35 6,30

(Keyed SAE "B-B") (KEYED NON SAE)

(KEYED ISO R775)

(FLANGE ISO 3019/2 100A2HW)

(FLANGE SAE "B")

SHAFT CODE 2

T7BBS

SHAFT CODE 1

SHAFT CODE 5

T7BB

SHAFT CODE 3 SAE B INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 16/32 13 TEETH - 30° PRESSURE ANGLE

SHAFT CODE 4 SAE B-B INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 16/32

15 TEETH - 30° PRESSURE ANGLE

76,2

P2

C.G.

116,1

Shaft torque limits [ml/rev. x bar]Shaft Vi x p max.

1 14300

2 21420

3 20600

4 32670

5 25300

1) B11 - B12 - B14 = 300 bar max. int. 2) B15 = 280 bar max. int.

opeRaTiNGChaRaCTeRisTiCs-TypiCal[24cst]

Model T7BB T7BBSCode M0 M1 00 01Ø A M10 x 19 deep 3/8"-16 UNC x 19 deep

Ø B M12 x 22,4 deep 1/2"-13 UNC x 22,4 deep

C 26,20 22,25 26,20 22,25

D 52,4 47,65 52,4 47,65

Ø E 25,4 19,1 25,4 19,1

F 140 146

G 70 73

Ø H 14,0 14,3

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 320 bar p = 7 bar p = 140 bar p = 320 bar

P1

&

P2

B02 5,8 ml/rev 8,7 7,0 4,8 0,5 2,6 5,4

B03 9,8 ml/rev 14,7 13,0 10,8 0,6 4,0 8,6

B04 12,8 ml/rev 19,2 17,5 15,3 0,6 5,0 11,0

B05 15,9 ml/rev 23,9 22,2 20,0 0,7 6,1 13,5

B06 19,8 ml/rev 29,7 28,0 25,8 0,7 7,5 16,6

B07 22,5 ml/rev 33,7 32,0 29,9 0,8 8,5 18,8

B08 24,9 ml/rev 37,4 35,7 33,5 0,8 9,3 20,7

B09 28,0 ml/rev 42,0 40,3 38,1 0,9 10,4 23,2

B10 31,8 ml/rev 47,7 46,0 43,8 0,9 11,7 26,2

B11 35,0 ml/rev 52,5 50,8 48,91) 1,0 12,8 27,01)

B12 41,0 ml/rev 61,5 59,8 57,91) 1,1 14,9 31,51)

B14 45,0 ml/rev 67,5 65,8 63,91) 1,2 16,3 34,51)

B15 50,0 ml/rev 75,0 73,3 71,62) 1,3 18,1 35,72)

Page 32: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

32 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T6CC W - 022 - 008 - 1 R 00 - C 1 00 - ..

Series - SAE B 2 boltsJ744 mounting flange

Severe duty shaft option

Displacement P1 and P2Volumetric displacement (ml/rev.)003 = 10,8 017 = 58,3005 = 17,2 020 = 63,8006 = 21,3 022 = 70,3008 = 26,4 025 = 79,3010 = 34,1 028 = 88,8012 = 37,1 031 = 100,0014 = 46,0

Type of shaft Severe duty shaft (T6CCW only)1 = keyed (non SAE) 2 = keyed (SAE BB)3 = splined (SAE BB) 15 teeth5 = splined (SAE B) 13 teeth

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

Modifications

Mounting w/connection variables

P1 = 1" - S = 3"UNC thread Metric thread00 01 0M W0

P2 1" 3/4"1) 1" 3/4

P1 = 1" - S = 2.1/2"2)

UNC thread Metric thread10 11 1M W1

P2 1" 3/4"1) 1" 3/41) up to 46 ml/rev. max.2) up to 126 ml/rev. max.Always select the largest cartridge in the front place.

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON® - 7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination (see page 72) 00 = standard

Noiselevel(TypiCal)-T6CC-022-022iNTeRNalleaKaGe(TypiCal)

peRmissibleRadialloadpoweRlosshydRomeChaNiCal(TypiCal)

55

60

65

70

75

0 40 80 120 160 200 240

Série1Série2

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

200

400

600

800

1000

1200

1400

600 1000 1400 1800 2200 2600

Shaftkeyed n°1

0

3

6

9

12

15

18

21

0 35 70 105 140 175 210 245 280

24 cSt10 cSt

P1-P2

P1-P2

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 800 NTotal hydromechanical power loss is the sum of each section loss under its respective operating conditions.

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss under its respective operating conditions.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

Double pump noise level is given with both stages discharging at the pressure value indicated on the curve.

T6CC-orderingCode

0

1

2

3

4

0 40 80 120 160 200 240 280

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2800 RPM

P1-P2

P1-P2

P1-P2

P1 P2

FaF

==

Shaft keyed N°1

Page 33: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

33 Parker HannifinDenison Vane Pump DivisionVierzon - France

T6CC-dimensions-weight:26,0kg

84,1

73,2

265,6 71,4

88,2 101,6 38,1174,5146,0

73,0

76,2

Ø14

,3

MOUNTING TORQUE : 159 Nm

D

MOUNTING TORQUE : 61Nm

9,7

6,4 MAXI

7,9

101,

6010

1,55

Ø

51,3

Ø

28,2

MAX

I

25,4

025

,37

Ø

1,5 x 45°

KEY 6,35 6,30

M8 x 16 DEEP

1,3 x 45° T6CCWSHAFT CODE 2

( Keyed SAE B-B )

24,5

MAX

I

22,2

2522

,200

Ø

KEY 4,762 4,712

58,27,9

SHAFT CODE 1

1,5 x 45°

Ø 25,4PRESSURESUCTION Ø HPRESSURE Ø C

F

A

B G 26,213,1

52,4

26,2

P2 P1S

E-4 HOLES 2)K-4 HOLES 2)E-4 HOLES 2)

45,57,9

24,5

1,5 x 45°

7,940,7

24,5

1,5 x 45°

SHAFT CODE 3 SAE BB INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 16/32

15 TEETH - 30° PRESSURE ANGLE

SHAFT CODE 5 SAE B INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 16/32 13 TEETH - 30° PRESSURE ANGLE

31,7

38,1

( Keyed nono SAE )

C.G.

126,0

Shaft torque limits [ml/rev. x bar]Shaft Vi x p max.

1 14300

2 21420

3 32670

5 20600

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 240 bar p = 7 bar p = 140 bar p = 240 bar

P1

&

P2

003 10,8 ml/rev 16,2 11,2 7,7 1,3 5,3 8,4

005 17,2 ml/rev 25,8 20,8 17,3 1,4 7,5 12,2

006 21,3 ml/rev 31,9 26,9 23,4 1,5 8,9 14,7

008 26,4 ml/rev 39,6 34,6 31,1 1,6 10,7 17,7

010 34,1 ml/rev 51,1 46,1 42,6 1,7 13,4 22,3

012 37,1 ml/rev 55,6 50,6 47,1 1,7 14,4 24,1

014 46,0 ml/rev 69,0 64,0 60,5 1,9 17,6 29,5

017 58,3 ml/rev 87,4 82,4 78,9 2,1 21,9 36,9

020 63,8 ml/rev 95,7 90,7 87,2 2,2 23,8 40,2

022 70,3 ml/rev 105,4 100,4 96,9 2,3 26,1 44,1

025 79,3 ml/rev 118,9 113,9 110,4 2,5 29,2 49,5

028 88,8 ml/rev 133,2 128,2 125,81) 2,8 32,7 48,51)

031 100,0 ml/rev 150,0 145,0 142,61) 2,8 36,5 54,41)

1) 028 - 031 = 210 bar max. int. 2) Port connection can be supplied with metric threads, please contact Parker Denison.

opeRaTiNGChaRaCTeRisTiCs-TypiCal[24cst]

Alternate portsS = 3" S = 2.1/2"2)

Code 00 011) 0M W01) 10 111) 1M W11)

A 52,4 47,7 52,4 47,7 52,4 47,7 52,4 47,7

B 26,2 22,4 26,2 22,4 26,2 22,4 26,2 22,4

Ø C 25,4 19,0 25,4 19,0 25,4 19,0 25,4 19,0

D 74,7 76,2 74,7 76,2 74,7 76,2 74,7 76,2

E 3/8"-16 UNC x 19 deep M10 x 19 deep 3/8"-16 UNC x 19 deep M10 x 19 deep

F 106,4 88,9

G 61,9 50,9

Ø H 76,2 63,5

K 5/8"-11UNC x 28,4 deep M16 x 28,4 deep 1/2"-13 UNC x 23,9 deep M12 x 23,9 deep1) Max. cam 014 2) P1 + P2 = 126 ml/rev. max.

Page 34: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

34 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T67CB W - 010 - B10 - 1 R 00 - A 1 M1 - ..

Series - SAE B 2 boltsJ744 mounting flangeSevere duty shaft

Displacement P1Volumetric displacement (ml/rev.)003 = 10,8 017 = 58,3005 = 17,2 020 = 63,8006 = 21,3 022 = 70,3008 = 26,4 025 = 79,3010 = 34,1 028 = 88,8012 = 37,1 031 = 100,0014 = 46,0

Displacement P2Volumetric displacement (ml/rev.)B02 = 5,8 B09 = 28,0B03 = 9,8 B10 = 31,8B04 = 12,8 B11 = 35,0B05 = 15,9 B12 = 41,0B06 = 19,8 B14 = 45,0B07 = 22,5 B15 = 50,0B08 = 24,9

Type of shaft Severe duty shaft (T67CW only)1 = keyed (non SAE) 2 = keyed (SAE BB)3 = splined (SAE BB) 15 teeth5 = splined (SAE B) 13 teeth

Modifications

Mounting w/connection variables11 = 4 bolts SAE flange(J518) UNC threadM1 = 4 bolts SAE flange(J518) Metric thread

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON® - 7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination(see page 72)00 = standard

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

Noiselevel(TypiCal)-T67CB-014-B03iNTeRNalleaKaGe(TypiCal)

peRmissiBleRadialloadpoweRlosshydRomeChaNiCal(TypiCal)

55

60

65

70

75

0 40 80 120 160 200 240

Série1

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

200

400

600

800

1000

1200

1400

600 1000 1400 1800 2200 2600

Shaftkeyed n°1

02468

10121416182022

0 50 100 150 200 250 300

24 cSt10 cSt

P2

P1

P1P2

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 800 NTotal hydromechanical power loss is the sum of each section loss under its respective operaring conditions.

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss under its respective operating conditions.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

Double pump noise level is given with both stages discharging at the pressure value indicated on the curve.

T67CB-orderingCode

0

1

2

3

4

5

0 40 80 120 160 200 240 280

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2800 RPM

P1

P1

P1

P1 P2

00,5

11,5

22,5

33,5

0 50 100 150 200 250 300

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2800 RPM P2

P2

P2

FaF

==

Shaft keyed N°1

Page 35: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

35 Parker HannifinDenison Vane Pump DivisionVierzon - France

T67CB-dimensions-weight:26,0kg

-

174,5146,0

73,0

76,2

Ø14

,3

MOUNTING TORQUE 159 NmMOUNTING TORQUE : 61 Nm

84,1

73,2

76,2

265,6 71,4

88,2 101,6 38,1 9,77,9

6,4 MAXI 38,1

101,

6010

1,55

Ø

51,3

Ø

28,2

2M

AXI

25,4

025

,37

Ø

1,5 x 45°

1,5 x 45°

3/8- 16 UNC x 19 DEEP - 4 HOLES(M10 x 19 DEEP - METRIC VERSION)

1/2- 13 UNC x 23,9 DEEP - 4 HOLES(M12 x 30,0 DEEP - METRIC VERSION)

3/8- 16 UNC x 19 DEEP - 4 HOLES(M10 x 20 DEEP - METRIC VERSION)

T67CBW SHAFT CODE 2

(Keyed SAE B-B)

1,5 x 45° 22,2

2522

,200

Ø 24,5

3M

AX

58,2

31,77,9

KEY 4,762 4,712

SHAFT CODE 1

P1SP2

12,7

26,213,150,822,2

Ø 25,4PRESSURE

52,4

26,288,

9

Ø 63.5SUCTIONØ 19PRESSURE

47,7

7,924,5

40,7

1,5 x 45°

45,57,9

24,5

1,5 x 45°

SHAFT CODE 3 SAE BB INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 16/32

15 TEETH - 30° PRESSURE ANGLE

SHAFT CODE 5 SAE B INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 16/32 13 TEETH - 30° PRESSURE ANGLE

KEY 6,35 6,30

M8 x 16 DEEP

(Keyed no SAE)

C.G.

126,0

Shaft torque limits [ml/rev. x bar]Shaft Vi x p max. Shaft Vi x p max.

1 14300 3 326702 21420 5 20600

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 275 bar p = 7 bar p = 140 bar p = 275 bar

P1

003 10,8 ml/rev 16,2 11,2 * 1,3 5,3 *

005 17,2 ml/rev 25,8 20,8 16,1 1,4 7,5 13,9

006 21,3 ml/rev 31,9 26,9 22,2 1,5 8,9 16,8

008 26,4 ml/rev 39,6 34,6 29,9 1,6 10,7 20,3

010 34,1 ml/rev 51,1 46,1 41,4 1,7 13,4 25,6

012 37,1 ml/rev 55,6 50,6 45,9 1,7 14,4 27,6

014 46,0 ml/rev 69,0 64,0 59,3 1,9 17,6 33,7

017 58,3 ml/rev 87,4 82,4 77,7 2,1 21,9 42,2

020 63,8 ml/rev 95,7 90,7 86,0 2,2 23,8 46,0

022 70,3 ml/rev 105,4 100,4 95,7 2,3 26,1 50,4

025 79,3 ml/rev 118,9 113,9 109,2 2,5 29,2 56,6

028 88,8 ml/rev 133,2 128,2 125,81) 2,8 32,7 48,51)

031 100,0 ml/rev 150,0 145,0 142,61) 2,8 36,5 54,41)

p = 0 bar p = 140 bar p = 300 bar p = 7 bar p = 140 bar p = 300 bar

P2

B02 5,8 ml/rev 8,7 7,0 5,1 0,5 2,6 5,1

B03 9,8 ml/rev 14,7 13,0 11,1 0,6 4,0 8,1

B04 12,8 ml/rev 19,2 17,5 15,6 0,6 5,0 10,4

B05 15,9 ml/rev 23,9 22,2 20,2 0,7 6,1 12,7

B06 19,8 ml/rev 29,7 28,0 26,1 0,7 7,5 15,6

B07 22,5 ml/rev 33,7 32,0 30,2 0,8 8,5 17,6

B08 24,9 ml/rev 37,4 35,7 33,7 0,8 9,3 19,5

B09 28,0 ml/rev 42,0 40,3 38,4 0,9 10,4 21,8

B10 31,8 ml/rev 47,7 46,0 44,1 0,9 11,7 26,2

B11 35,0 ml/rev 52,5 50,8 48,9 1,0 12,8 27,0

B12 41,0 ml/rev 61,5 59,8 57,9 1,1 14,9 31,5

B14 45,0 ml/rev 67,5 65,8 63,9 1,2 16,3 34,5

B15 50,0 ml/rev 75,0 73,3 71,62) 1,3 18,1 35,72)

* We do not recommand to use the size 003 in P1 at 275 bar & 1500 RPM as the internal is over 50% of theoretical flow.1) 028 - 031 = 210 bar max. int. 2) B15 = 280 bar max.int.

opeRaTiNGChaRaCTeRisTiCs-TypiCal[24cst]

Page 36: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

36 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T7DB or T7DBS - B42 - B10 - 1 R 00 - A 1 M1 - ..T7DB series - 125 A2 HWISO 2 bolts 3019-2 mounting flangeT7DBS series - SAE C 2 boltsJ744 mounting flange

Displacement P1Volumetric displacement (ml/rev.)B14 = 44,0 B31 = 99,2B17 = 55,0 B35 = 113,4B20 = 66,0 B38 = 120,6B22 = 70,3 B42 = 137,5B24 = 81,1 045 = 145,7B28 = 90,0 050 = 158,0

Displacement P2Volumetric displacement (ml/rev.)B02 = 5,8 B09 = 28,0B03 = 9,8 B10 = 31,8B04 = 12,8 B11 = 35,0B05 = 15,9 B12 = 41,0B06 = 19,8 B14 = 45,0B07 = 22,5 B15 = 50,0B08 = 24,9

Type of shaft T7DBS1 = keyed (SAE C) 3 = splined (SAE C) 14 teeth 2 = keyed (non SAE) 4 = splined (spec. SAE C)Type of shaft T7DB - T7DBS5 = keyed (ISO 3019 -2 - G32 M)

Modifications

Mounting w/connection variables4 bolts SAE flanges J518

Metric threadT7DB - T7DBS

UNC threadT7DBS

M0 M1 00 01

P1 1.1/4" 1.1/4" 1.1/4" 1.1/4"

P2 1" 3/4" 1" 3/4"

S 3" 3" 3" 3"

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON® - 7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination (see page 72)00 = standard

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

Noiselevel(TypiCal)-T7DBs-B31-B10iNTeRNalleaKaGe(TypiCal)

peRmissiBleRaDialloaDpoweRlosshyDRomeChaNiCal(TypiCal)

55

60

65

70

75

0 40 80 120 160 200 240

Série1

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

400

600

800

1000

1200

1400

1600

1800

2000

600 900 1200 1500 1800 2100 2400

Shaftkeyed

02468

10121416182022

0 50 100 150 200 250 300

24 cSt10 cSt

P2

P2

P1

P1

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 1200 NTotal hydromechanical power loss is the sum of each section loss under its respective operating conditions.

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss under its respective operating conditions.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

Double pump noise level is given with both stages discharging at the pressure value indicated on the curve.

T7DB/T7DBs-orderingCode

0123456

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2500 RPM

P1

P1

P1

P1 P2

00,5

11,5

22,5

33,5

0 50 100 150 200 250 300

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2500 RPM P2

P2

P2

FaF

==

Shaft keyed N°1

Page 37: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

37 Parker HannifinDenison Vane Pump DivisionVierzon - France

T7DB/DBs-Dimensions-weight:38,6kg

7,955,2

38,0

2,3 x 45°

7,977,7

48,02

2,3 x 45°

B

A 62,0

106,

4

58,7

31,7

531

,70

35,2

7M

AXI

2,3 x 45°

38,1

7,973,215,7

30,2

P2 S P1

Ø 76SUCTION

KEY 7,94 7,89

31,7

531

,70

35,2

7M

AXI

49,30

M10 x 20 DEEP

KEY 7,94 7,89

2,30 x 45°

S64,3

0

e x 45°

7,906,35 MAXI

W38,10114,30109,50286,00

74,7

074

,05

88,9

0

83,60

MOUNTING TORQUE 68NmMOUNTING TORQUE 187 Nm

DIA

d

KK/2

212,40

( Keyed SAE C )

SHAFT CODE 2

SHAFT CODE 1

SHAFT CODE 4 SAE *C Spc INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 12/24

14 TEETH - 30° PRESSURE ANGLE

SHAFT CODE 3 SAE C INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 12/24 14 TEETH - 30° PRESSURE ANGLE

82,6

0

*

P2 S P1

7/16 14 UNC 22.3 DEEP - 4 HOLESM12 x 22.3 DEEP - METRIC VERSION

5/8 11 UNC 28.5 DEEP - 4 HOLESM16 x 28.4 DEEP - METRIC VERSION

3/8 16 UNC 19 DEEP - 4 HOLESM10 x 19.0 DEEP - METRIC VERSION

M10

x 2

0 D

EEP

SHAFT CODE 5

KEY 10 x 850,0

87,97,9

32,0

1832

,002

35,0

MAX

I

2,3 x 45°

( Keyed non SAE ) ( Keyed ISO/R775 - G32M )

PRESSURE Ø CPRESSURE Ø 31,8

C.G.

129,5

ØØ

Ø Ø

Ø

Shaft torque limits [ml/rev. x bar]Shaft Vi x p max. Shaft Vi x p max.

1 43240 4 612002 34590 5 425003 61200

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 250 bar p = 7 bar p = 140 bar p = 250 bar

P1

B14 44,0 ml/rev 66,0 59,4 54,2 1,5 16,6 29,0

B17 55,0 ml/rev 82,5 75,9 70,7 1,7 20,4 35,8

B20 66,0 ml/rev 99,0 92,4 87,2 1,9 24,3 42,7

B22 70,3 ml/rev 105,5 98,8 93,7 2,0 25,8 45,4

B24 81,1 ml/rev 121,7 115,0 109,9 2,2 29,5 52,1

B28 90,0 ml/rev 135,0 128,4 123,2 2,3 32,7 57,7

B31 99,2 ml/rev 148,8 142,2 137,0 2,5 35,9 63,5

B35 113,4 ml/rev 170,1 163,5 158,3 2,7 40,8 72,3

B38 120,6 ml/rev 180,9 174,3 169,1 2,9 43,4 76,8

B42 137,5 ml/rev 206,3 199,6 194,5 3,2 49,3 87,4

045 145,7 ml/rev 218,6 209,2 202,6 4,1 52,8 89,5

050 158,0 ml/rev 237,0 227,7 223,01) 4,4 57,1 85,01)

p = 0 bar p = 140 bar p = 300 bar p = 7 bar p = 140 bar p = 300 bar

P2

B02 5,8 ml/rev 8,7 7,0 5,1 0,5 2,6 5,1

B03 9,8 ml/rev 14,7 13,0 11,1 0,6 4,0 8,1

B04 12,8 ml/rev 19,2 17,5 15,6 0,6 5,0 10,4

B05 15,9 ml/rev 23,9 22,2 20,2 0,7 6,1 12,7

B06 19,8 ml/rev 29,7 28,0 26,1 0,7 7,5 15,6

B07 22,5 ml/rev 33,7 32,0 30,2 0,8 8,5 17,6

B08 24,9 ml/rev 37,4 35,7 33,7 0,8 9,3 19,5

B09 28,0 ml/rev 42,0 40,3 38,4 0,9 10,4 21,8

B10 31,8 ml/rev 47,7 46,0 44,1 0,9 11,7 26,2

B11 35,0 ml/rev 52,5 50,8 48,9 1,0 12,8 27,0

B12 41,0 ml/rev 61,5 59,8 57,9 1,1 14,9 31,5

B14 45,0 ml/rev 67,5 65,8 63,9 1,2 16,3 34,5

B15 50,0 ml/rev 75,0 73,3 71,62) 1,3 18,1 35,72)

1) 050 = 210 bar max. int. 2) B15 = 280 bar max.int.

opeRaTiNGChaRaCTeRisTiCs-TypiCal[24cst]

Alternate mounting flange

Dia Se x 45° W K Dia d

Max. Min.

T7DB 125,000 124,937 2,0 9,5 180,0 18,0

T7DBS 127,000 126,950 1,3 12,7 181,0 17,5

Alternate connect. variables00 & M0 01 & M1

A 26,20 22,20B 52,35 47,6C 25,0 19,0

Page 38: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

38 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T67DC W - B42 - 010 - 1 R 00 - A 1 M1 - ..Series - SAE C 2 boltsJ744 mounting flange

Severe duty shaft option

Displacement P1Volumetric displacement (ml/rev.)B14 = 44,0 B31 = 99,2B17 = 55,0 B35 = 113,4B20 = 66,0 B38 = 120,6B22 = 70,3 B42 = 137,5B24 = 81,1 045 = 145,7B28 = 90,0 050 = 158,0

Displacement P2Volumetric displacement (ml/rev.)003 = 10,8 017 = 58,3005 = 17,2 020 = 63,8006 = 21,3 022 = 70,3008 = 26,4 025 = 79,3010 = 34,1 028 = 88,8012 = 37,1 031 = 100,0014 = 46,0

Type of shaft1 = keyed (SAE C) 3 = splined (SAE C) 14 teeth 2 = keyed (non SAE) 4 = splined (spec. SAE C)Type of shaft - Severe duty (T67DCW only)5 = keyed (non SAE)

Modifications

Mounting w/connection variables4 bolts SAE flanges J518

Metric thread UNC thread

M0 M1 00 01

P1 1.1/4" 1.1/4" 1.1/4" 1.1/4"

P2 1" 3/4" 1" 3/4"

S 3" 3" 3" 3"

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON® - 7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination (see page 72)00 = standard

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

Noiselevel(TypiCal)-T67DC-B31-022iNTeRNalleaKaGe(TypiCal)

peRmissiBleRaDialloaDpoweRlosshyDRomeChaNiCal(TypiCal)

60

65

70

75

80

0 40 80 120 160 200 240

Série1

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

400

600

800

1000

1200

1400

1600

1800

2000

600 900 1200 1500 1800 2100 2400

Shaftkeyed

02468

10121416182022

0 35 70 105 140 175 210 245 280

24 cSt10 cSt

P2

P2P1

P1

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 1200 NTotal hydromechanical power loss is the sum of each section loss under its respective operating conditions.

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss under its respective operating conditions.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

Double pump noise level is given with both stages section dischar-ging at the pressure value indicated on the curve.

T67DC-orderingCode

0

1

2

3

4

5

6

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2500 RPM

P1

P1

P1

P1 P2

0

1

2

3

4

0 40 80 120 160 200 240 280

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2500 RPM P2

P2P2

FaF

==

Shaft keyed N°1

Page 39: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

39 Parker HannifinDenison Vane Pump DivisionVierzon - France

T67DC-Dimensions-weight:38,6kg

-

181,0090,50

82,6

0

Ø17

,50

MOUNTING TORQUE : 187 Nm MOUNTING TORQUE : 68 Nm

74,0

588

,90

74,7

0

286,00212,40 109,50 114,30 38,10 12,66

7,906,35 MAXI 49,30

83,60

127,

0012

6,95

Ø

64,3

35,2

7M

AXI

31,7

531

,70

Ø

2,30 x 45°

1,30 x 45°

B

A13,10

61,9030,95

30,2015,10

106,

4053

,20

58,7

029

,35

15,707,90

73,20

38,10

35,2

7M

AXI

31,7

531

,70

Ø

2,30 x 45°

7/16-14 UNC x 22,3 DEEP-4 HOLES( M12 x 22,3 DEEP - METRIC VERSION )5/8-11 UNC x 28,5 DEEP-4 HOLES

( M16 x 28,4 DEEP - METRIC VERSION )3/8-16 UNC x 19 DEEP-4 HOLES

(M10 x 19 DEEP - METRIC VERSION )

P2 S P1

77,707,90

48,002,30 x 45°

55,207,90

38,002,30 x 45°

Ø 31,8PRESSUREØ 76SUCTIONØ CPRESSURE

SHAFT CODE 2

KEY 7,94 7,89

M10 x 20 DEEP

SHAFT CODE 1( Keyed SAE C )

KEY 7,94 7,89

M8

16 D

EE

P34

,900

34,8

75Ø

38,4

2M

AXI

60,007,9083,40

2,30 x 45°

T67DCW

SHAFT CODE 5 SHAFT CODE 4 SAE*C Spc INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - 12/24 dp

14 TEETH - 30° PRESSURE ANGLE

SHAFT CODE 3 SAE C INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 12/24 14 TEETH - 30° PRESSURE ANGLE

*KEY 7,94

7,89

( Keyed no SAE )( Keyed no SAE )

C.G.

128,3

Shaft torque limits [ml/rev. x bar]Shaft Vi x p max. Shaft Vi x p max.

1 43240 4 612002 34590 5 556003 61200

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 250 bar p = 7 bar p = 140 bar p = 250 bar

P1

B14 44,0 ml/rev 66,0 59,4 54,2 1,5 16,6 29,0

B17 55,0 ml/rev 82,5 75,9 70,7 1,7 20,4 35,8

B20 66,0 ml/rev 99,0 92,4 87,2 1,9 24,3 42,7

B22 70,3 ml/rev 105,5 98,8 93,7 2,0 25,8 45,4

B24 81,1 ml/rev 121,7 115,0 109,9 2,2 29,5 52,1

B28 90,0 ml/rev 135,0 128,4 123,2 2,3 32,7 57,7

B31 99,2 ml/rev 148,8 142,2 137,0 2,5 35,9 63,5

B35 113,4 ml/rev 170,1 163,5 158,3 2,7 40,8 72,3

B38 120,6 ml/rev 180,9 174,3 169,1 2,9 43,4 76,8

B42 137,5 ml/rev 206,3 199,6 194,5 3,2 49,3 87,4

045 145,7 ml/rev 218,6 209,2 202,6 4,1 52,8 89,5

050 158,0 ml/rev 237,0 227,7 223,01) 4,4 57,1 85,01)

p = 0 bar p = 140 bar p = 275 bar p = 7 bar p = 140 bar p = 275 bar

P2

003 10,8 ml/rev 16,2 11,2 * 1,3 5,3 *

005 17,2 ml/rev 25,8 20,8 16,1 1,4 7,5 13,9

006 21,3 ml/rev 31,9 26,9 22,2 1,5 8,9 16,8

008 26,4 ml/rev 39,6 34,6 29,9 1,6 10,7 20,3

010 34,1 ml/rev 51,1 46,1 41,4 1,7 13,4 25,6

012 37,1 ml/rev 55,6 50,6 45,9 1,7 14,4 27,6

014 46,0 ml/rev 69,0 64,0 59,3 1,9 17,6 33,7

017 58,3 ml/rev 87,4 82,4 77,7 2,1 21,9 42,2

020 63,8 ml/rev 95,7 90,7 86,0 2,2 23,8 46,0

022 70,3 ml/rev 105,4 100,4 95,7 2,3 26,1 50,4

025 79,3 ml/rev 118,9 113,9 109,2 2,5 29,2 56,6

028 88,8 ml/rev 133,2 128,2 125,81) 2,8 32,7 48,51)

031 100,0 ml/rev 150,0 145,0 142,61) 2,8 36,5 54,41)

* We do not recommand to use the size 003 in P2 at 275 bar & 1500 RPM as the internal leakage is over 50% of theoretical flow.1) 050 - 028 - 031 = 210 bar max. int.

opeRaTiNGChaRaCTeRisTiCs-TypiCal[24cst]

Alternate connect. variables00 & M0 01 & M1

A 26,20 22,20B 52,35 47,60C 25,00 19,00

Page 40: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

40 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T7DD or T7DDS - B42 - B22 - 1 R 00 - A 1 M0 - ..T7DD series - ISO 4 bolts 3019-2Mounting flange 125-B4 HWT7DDS series - SAE C 6 boltsJ744 mounting flange

Displacement P1 & P2Volumetric displacement (ml/rev.)B14 = 44,0 B31 = 99,2B17 = 55,0 B35 = 113,4B20 = 66,0 B38 = 120,6B22 = 70,3 B42 = 137,5B24 = 81,1 045 = 145,7B28 = 90,0 050 = 158,0

Type of shaft1 = keyed (SAE C) 3 = splined (SAE C) 14 teeth 2 = keyed (SAE CC) 4 = splined (SAE BB)Type of shaft - T7DD and T7DDS5 = keyed (ISO 3019-2 - G32M)

Modifications

Mounting w/connection variables4 bolts SAE flanges J518

P1 & P2 = 1.1/4" - S = 4"

Type Metric thread UNC thread

T7DD M0

T7DDS M0 00

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON® - 7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination (see page 72)00 = standard

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

Noiselevel(TypiCal)-T7DDs-B31-B31iNTeRNalleaKaGe(TypiCal)

peRmissiBleRaDialloaDpoweRlosshyDRomeChaNiCal(TypiCal)

60

65

70

75

80

0 40 80 120 160 200 240

Série1

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

400

600

800

1000

1200

1400

1600

1800

2000

600 900 1200 1500 1800 2100 2400

Shaftkeyed

0

2

4

6

8

10

12

14

16

18

20

22

0 30 60 90 120 150 180 210 240

24 cSt10 cSt

P1-P2

P1-P2

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 1200 NTotal hydromechanical power loss is the sum of each section loss under its respective operaring conditions.

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss under its respective operating conditions.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

Double pump noise level is given with both stages discharging at the pressure value indicated on the curve.

T7DD/T7DDs-orderingCode

0

1

2

3

4

5

6

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2500 RPM P1-P2

P1-P2

P1-P2

P1 P2

FaF

==

Shaft keyed N°1

Page 41: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

41 Parker HannifinDenison Vane Pump DivisionVierzon - France

T7DD/DDs-Dimensions-weight:56kg

P1P2 S

46,0

7,924,5

1,5 x 45°

213,0K1K2

K2

Ø d2

Ø d

1 101,

691

,3

347,7 84,0

134,2 148,3 38,3 w7,9

6,4 MAXI

49,3

Ø S64

,3Ø

35,2

7M

AXI

31,7

531

,70

Ø

M10

x 2

0 D

EEP

2,3 x 45°

e x 45°

19,0

114,

9

56,07,9

6,4 MAXI

2,3 x 45°

38,0

30,2

58,7

77,8

130,

2

Ø 101,6SUCTION 31,8PRESSURE ØØ 29,5PRESSURE

58,7

162,

2

7/16- 14UNC x 24 DEEPM12 x 24 DEEP-METRIC VERSION 30,2

5/8- 11UNC x 30 DEEPM16 x 30 DEEP-METRIC VERSION

7/16- 14UNC x 22,3 DEEPM12 x 22,3 DEEP-METRIC VERSION

7,9

91,0

50,8

2,3 x 45°

KEY 9,52 9,47

42,3

6M

AXI

38,1

038

,05

Ø

M10

x 2

0 D

EEP

M10

x 2

0 D

EEP

SHAFT CODE 1

SHAFT CODE 5

SHAFT CODE 2

Keyed SAE C

Keyed SAE CC

SHAFT CODE 3 SAE C INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 12/24 14 TEETH - 30° PRESSURE ANGLE

SHAFT CODE 4 SAE BB INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 16/32

15 TEETH - 30° PRESSURE ANGLE

P2 S P1

KEY 10 x 850,0

68,010,0

32,0

1832

,002

Ø 35,0

0M

AXI

Keyed ISO 3019/2 -G32M

MOUNTING TORQUE : 190 Nm MOUNTING TORQUE : 190 Nm

101,

6

Key 7,94

7,89

182,

0

C.G.

170,9

Shaft torque limits [ml/rev. x bar]Shaft Vi x p max. Shaft Vi x p max.

1 43240 4 358802 71750 5 452003 61200

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 250 bar p = 7 bar p = 140 bar p = 250 bar

P1

&

P2

B14 44,0 ml/rev 66,0 59,4 54,2 1,5 16,6 29,0

B17 55,0 ml/rev 82,5 75,9 70,7 1,7 20,4 35,8

B20 66,0 ml/rev 99,0 92,4 87,2 1,9 24,3 42,7

B22 70,3 ml/rev 105,5 98,8 93,7 2,0 25,8 45,4

B24 81,1 ml/rev 121,7 115,0 109,9 2,2 29,5 52,1

B28 90,0 ml/rev 135,0 128,4 123,2 2,3 32,7 57,7

B31 99,2 ml/rev 148,8 142,2 137,0 2,5 35,9 63,5

B35 113,4 ml/rev 170,1 163,5 158,3 2,7 40,8 72,3

B38 120,6 ml/rev 180,9 174,3 169,1 2,9 43,4 76,8

B42 137,5 ml/rev 206,3 199,6 194,5 3,2 49,3 87,4

045 145,7 ml/rev 218,6 209,2 202,6 4,1 52,8 89,5

050 158,0 ml/rev 237,0 227,7 223,01) 4,4 57,1 85,01)

1) 050 = 210 bar max. int.

opeRaTiNGChaRaCTeRisTiCs-TypiCal[24cst]

Alternate mounting flange

SeriesDia S

e x 45° W K1 Dia d1 K2 Dia d2Max. Min.

T7DD 125,000 124,937 2,0 9,5 180,0 18,0 113,14 14,0

T7DDS 127,000 126,950 1,3 12,7 181,0 17,5 114,50 14,3

Page 42: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

42 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T7EB or T7EBS - 042 - B12 - 1 R 00 - A 1 M1 - ..T7EB series - ISO 4 bolts 3019-2Mounting flange 125-A2 HWT7EBS series - SAE C 2 boltsJ744 mounting flange

Displacement P1Volumetric displacement (ml/rev.)042 = 132,3 057 = 183,3045 = 142,4 062 = 196,7050 = 158,5 066 = 213,3052 = 164,8 072 = 227,1054 = 171,0 085 = 268,7

Displacement P2Volumetric displacement (ml/rev.)B02 = 5,8 B09 = 28,0B03 = 9,8 B10 = 31,8B04 = 12,8 B11 = 35,0B05 = 15,9 B12 = 41,0B06 = 19,8 B14 = 45,0B07 = 22,5 B15 = 50,0B08 = 24,9

Type of shaft T7EBS1 = keyed (SAE CC) 3 = splined (SAE C) 14 teeth 2 = keyed (non SAE) 4 = splined (SAE CC)Type of shaft T7EB - T7EBS5 = keyed (ISO /R 775 - G38 M)

Modifications

Mounting w/connection variables4 bolts SAE flanges J518

P1 = 1.1/2" - P2 = 3/4" - S = 3.1/2"

Metric threadT7EB - T7EBS

UNC threadT7EBS

Code M1 01

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON® - 7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination (see page 72)00 = standard

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

Noiselevel(TypiCal)-T7eBs-050-B03iNTeRNalleaKaGe(TypiCal)

peRmissiBleRadialloadpoweRlosshydRomeChaNiCal(TypiCal)

60

65

70

75

80

0 40 80 120 160 200 240

Série1

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

400

600

800

1000

1200

1400

1600

1800

2000

600 1000 1400 1800 2200

Shaftkeyed

0

36

9

1215

18

2124

2730

33

0 50 100 150 200 250 300

24 cSt10 cSt

P2

P2

P1

P1

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 2000 NTotal hydromechanical power loss is the sum of each section loss under its respective operating conditions.

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss under its respective operating conditions.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

Double pump noise level is given with both stages discharging at the pressure value indicated on the curve.

T7eB/T7eBs-orderingCode

01234567

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2200 RPM P1

P1

P1

P1 P2

00,5

11,5

22,5

3

0 50 100 150 200 250 300

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2200 RPM P2

P2

P2

FaF

==

Shaft keyed N°1

Page 43: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

43 Parker HannifinDenison Vane Pump DivisionVierzon - France

T7eB/eBs-dimensions-weight:55,0kg

213,0K

K/2

Ø d

76,2

74,7

331,6136,7 118,5 52,3 W

7,96,4 MAX

90,9

50,8

Ø S76

,2Ø42

,4M

AX

38,1

0038

,075

Ø

2,3 x 45°

SHAFT CODE 1( Keyed SAE CC )

e x 45°

98,4

102,

488

,9

MOUNTING TORQUE 187 Nm.MOUNTING TORQUE : 68 Nm.

55,97,9

38,1

2,3 x 45°

62,2*7,931,5

2,3x 45°

SHAFT CODE 3 SAE C INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 12/24 14 TEETH - 30° PRESSURE ANGLE

SHAFT CODE 4 SAE *CC INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 12/24

17 TEETH - 30° PRESSURE ANGLE

P1SP247,6

22,2

120,

660

,3

69,834,9

69,8

35,7

7,938,1

KEY 7,94 7,89

35,3

MAX

31,7

531

,70

Ø

2,3 x 45°

SHAFT CODE 2

Ø 37,10PRESSUREØ 88,90SUCTIONØ 19,00PRESSURE

C x 19 DEEP - 4 HOLES B x 29,5 DEEP - 4 HOLES A x 23,4 DEEP - 4 HOLES

KEY 9,52 9,47

M10 x 20 DEEP

T7EBS

T7EB61,9

(Keyed no SAE )

2,3 x 45°

10,090,0

50,0

41,3

MAX

Ø S

38,0

1838

,002

Ø

KEY 10 x 8

M10 x 20 DEEP

W

SHAFT CODE 5 ( Keyed ISO/R775 - G38M)

C.G.

149,1

e x 45°

Shaft torque limits [ml/rev. x bar]Shaft Vi x p max. Shaft Vi x p max.

1 68500 4 685002 34590 5 685003 61200

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 240 bar p = 7 bar p = 140 bar p = 240 bar

P1

042 132,3 ml/rev 198,5 188,5 181,3 5,2 49,4 82,6

045 142,4 ml/rev 213,6 203,6 196,5 5,4 52,9 88,7

050 158,5 ml/rev 237,7 227,7 220,6 5,7 58,5 98,3

052 164,8 ml/rev 247,2 237,2 230,1 5,8 60,8 102,1

054 171,0 ml/rev 256,5 246,5 239,4 5,9 63,0 105,8

057 183,3 ml/rev 275,0 265,0 257,9 6,1 67,3 113,2

062 196,7 ml/rev 295,0 285,0 277,9 6,4 71,9 121,3

066 213,3 ml/rev 319,9 309,0 302,8 6,7 77,7 131,2

072 227,1 ml/rev 340,6 330,6 323,5 6,9 82,6 139,5

085 268,7 ml/rev 403,0 392,01) - 9,1 65,81) -

p = 0 bar p = 140 bar p = 300 bar p = 7 bar p = 140 bar p = 300 bar

P2

B02 5,8 ml/rev 8,7 7,0 5,1 0,5 2,6 5,1

B03 9,8 ml/rev 14,7 13,0 11,1 0,6 4,0 8,1

B04 12,8 ml/rev 19,2 17,5 15,6 0,6 5,0 10,4

B05 15,9 ml/rev 23,9 22,2 20,2 0,7 6,1 12,7

B06 19,8 ml/rev 29,7 28,0 26,1 0,7 7,5 15,6

B07 22,5 ml/rev 33,7 32,0 30,2 0,8 8,5 17,6

B08 24,9 ml/rev 37,4 35,7 33,7 0,8 9,3 19,5

B09 28,0 ml/rev 42,0 40,3 38,4 0,9 10,4 21,8

B10 31,8 ml/rev 47,7 46,0 44,1 0,9 11,7 26,2

B11 35,0 ml/rev 52,5 50,8 48,9 1,0 12,8 27,0

B12 41,0 ml/rev 61,5 59,8 57,9 1,1 14,9 31,5

B14 45,0 ml/rev 67,5 65,8 63,9 1,2 16,3 34,5

B15 50,0 ml/rev 75,0 73,3 71,62) 1,3 18,1 35,72)

1) 085 = 90 bar max. int. 2) B15 = 280 bar max.int.

opeRaTiNGChaRaCTeRisTiCs-TypiCal[24cst]

Alternate mounting flange

Dia Se x 45° W K Dia d

Max. Min.

T7EB 125,000 124,937 2,0 9,5 180,0 18,0

T7EBS 127,000 126,950 1,3 12,7 181,0 17,5

Alternate connect. variables01 M1

A 1/2" - 13 UNC M12B 5/8" - 11 UNC M16C 3/8" - 16 UNC M10

Page 44: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

44 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T67EC - 085 - 020 - 1 R 00 - A 1 00 - ..Series - SAE C 2 boltsJ744 mounting flange

Displacement P1Volumetric displacement (ml/rev.)042 = 132,3 057 = 183,3045 = 142,4 062 = 196,7050 = 158,5 066 = 213,3052 = 164,8 072 = 227,1054 = 171,0 085 = 268,7

Displacement P2Volumetric displacement (ml/rev.)003 = 10,8 017 = 58,3005 = 17,2 020 = 63,8006 = 21,3 022 = 70,3008 = 26,4 025 = 79,3010 = 34,1 028 = 88,8012 = 37,1 031 = 100,0014 = 46,0

Type of shaft1 = keyed (SAE CC)2 = keyed (non SAE) 3 = splined (SAE C) 14 teeth4 = splined (SAE CC) 17 teeth

Modifications

Mounting w/connection variables4 bolts SAE flanges J518

Metric thread UNC thread

Code M0 M1 00 01

P1 1.1/2" 1.1/2" 1.1/2" 1.1/2"

P2 1" 3/4" 1" 3/4"

S 3.1/2" 3.1/2" 3.1/2" 3.1/2"

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON® - 7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination (see page 72)00 = standard

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

Noiselevel(TypiCal)-T67eC-050-022iNTeRNalleaKaGe(TypiCal)

peRmissibleRadialloadpoweRlosshydRomeChaNiCal(TypiCal)

60

65

70

75

80

0 40 80 120 160 200 240

Série1

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

400

600

800

1000

1200

1400

1600

1800

2000

600 1000 1400 1800 2200

Shaftkeyed

0

3

6

9

12

15

18

21

24

27

30

33

0 40 80 120 160 200 240 280

24 cSt10 cSt

P2

P2

P1

P1

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 2000 NTotal hydromechanical power loss is the sum of each section loss under its respective operating conditions.

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss under its respective operating conditions.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

Double pump noise level is given with both stages discharging at the pressure value indicated on the curve.

T67eC-orderingCode

01234567

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2200 RPM P1

P1

P1

P1 P2

0

1

2

3

4

0 40 80 120 160 200 240 280

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2200 RPM

P2

P2

P2

FaF

==

Shaft keyed N°1

Page 45: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

45 Parker HannifinDenison Vane Pump DivisionVierzon - France

T67eC-dimensions-weight:55,0kg

213,0

181,0

90,5

Ø 1

7,5

MOUNTING TORQUE : 187 Nm 61,917,57,9

38,1

KEY 7,94 7,89

31,7

31,

70

35,2

7M

AXI

2,3 x 45°

SHAFT CODE 2

SHAFT CODE 1( Keyed SAE CC )

127,

00Ø

126

,95

Ø 7

6,2

38,1

00Ø

38,

075

42,3

6M

AXI

2,3 x 45°

1,3 x 45°

102,

488

,9

74,7

76,2

331,6 90,9

136,7 118,5 52,3 12,77,9

6,4 MAXI

MOUNTING TORQUE : 68 Nm

35,7

17,8

69,9

34,926,2

13,1

52,4 26

,2

P2 S P1

Ø 25.4PRESSURE Ø 88,9SUCTION Ø 37,1PRESSURE

1/2-13 UNC x 23,4 DEEP - 4 HOLES(M12 x 23,4 DEEP -METRIC VERSION )

5/8-11 UNC x 29,5 DEEP - 4 HOLES(M16 x 29,5 DEEP - METRIC VERSION)

SHAFT CODE 3 SAE C INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 12/24 14 TEETH - 30° PRESSURE ANGLE

SHAFT CODE 4 SAE CC INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 12/24

17 TEETH - 30° PRESSURE ANGLE

50,8 KEY 9,52 9,47

98,4

M10 x 20 DEEP

62,27,9

3/8-16 UNC x 19 DEEP - 4 HOLES(M10 x 19 DEEP - METRIC VERSION)

31,5

2,3 x 45°

55,97,9

38,1

2,3 x 45°

( Keyed no SAE )

C.G.

149,1

Shaft torque limits [ml/rev. x bar]Shaft Vi x p max. Shaft Vi x p max.

1 72300 3 612002 34590 4 76300

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 240 bar p = 7 bar p = 140 bar p = 240 bar

P1

042 132,3 ml/rev 198,5 188,5 181,3 5,2 49,4 82,6

045 142,4 ml/rev 213,6 203,6 196,5 5,4 52,9 88,7

050 158,5 ml/rev 237,7 227,7 220,6 5,7 58,5 98,3

052 164,8 ml/rev 247,2 237,2 230,1 5,8 60,8 102,1

054 171,0 ml/rev 256,5 246,5 239,4 5,9 63,0 105,8

057 183,3 ml/rev 275,0 265,0 257,9 6,1 67,3 113,2

062 196,7 ml/rev 295,0 285,0 277,9 6,4 71,9 121,3

066 213,3 ml/rev 319,9 309,0 302,8 6,7 77,7 131,2

072 227,1 ml/rev 340,6 330,6 323,5 6,9 82,6 139,5

085 268,7 ml/rev 403,0 392,01) - 9,1 65,81) -

p = 0 bar p = 140 bar p = 275 bar p = 7 bar p = 140 bar p = 275 bar

P2

003 10,8 ml/rev 16,2 11,2 * 1,3 5,3 *

005 17,2 ml/rev 25,8 20,8 16,1 1,4 7,5 13,9

006 21,3 ml/rev 31,9 26,9 22,2 1,5 8,9 16,8

008 26,4 ml/rev 39,6 34,6 29,9 1,6 10,7 20,3

010 34,1 ml/rev 51,1 46,1 41,4 1,7 13,4 25,6

012 37,1 ml/rev 55,6 50,6 45,9 1,7 14,4 27,6

014 46,0 ml/rev 69,0 64,0 59,3 1,9 17,6 33,7

017 58,3 ml/rev 87,4 82,4 77,7 2,1 21,9 42,2

020 63,8 ml/rev 95,7 90,7 86,0 2,2 23,8 46,0

022 70,3 ml/rev 105,4 100,4 95,7 2,3 26,1 50,4

025 79,3 ml/rev 118,9 113,9 109,2 2,5 29,2 56,6

028 88,8 ml/rev 133,2 128,2 125,82) 2,8 32,7 48,52)

031 100,0 ml/rev 150,0 145,0 142,62) 2,8 36,5 54,42)

* We do not recommand to use the size 003 in P2 at 275 bar & 1500 RPM as the internal leakage is over 50% of theoretical flow.1) 085 = 90 bar max. int. 2) 028 - 031 = 210 bar max.int.

opeRaTiNGChaRaCTeRisTiCs-TypiCal[24cst]

Page 46: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

46 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T7ED or T7EDS - 042 - B22 - 1 R 00 - A 1 M0 - ..T7ED series - 125 A2 HWISO 2 bolts 3019-2 mounting flangeT7EDS series - SAE C 2 boltsJ744 mounting flange

Displacement P1Volumetric displacement (ml/rev.)042 = 132,3 057 = 183,3045 = 142,4 062 = 196,7050 = 158,5 066 = 213,3052 = 164,8 072 = 227,1054 = 171,0 085 = 268,7

Displacement P2Volumetric displacement (ml/rev.)B14 = 44,0 B31 = 99,2B17 = 55,0 B35 = 113,4B20 = 66,0 B38 = 120,6B22 = 70,3 B42 = 137,5B24 = 81,1 045 = 145,7B28 = 90,0 050 = 158,0

Type of shaft T7EDS1 = keyed (SAE CC) 3 = splined (SAE C) 14 teeth2 = keyed (non SAE) 4 = splined (SAE CC) 17 teeth

Type of shaft T7ED - T7EDS5 = keyed (ISO R775 - G38M)

Modifications

Mounting w/connection variables4 bolts SAE flanges J518

P1 = 1.1/2" - P2 = 1.1/4" - S = 4"

T7ED - T7EDS T7EDS

Type Metric thread UNC thread

Code M0 00

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON® - 7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination (see page 72)00 = standard

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

Noiselevel(TypiCal)-T7eDs-050-B31iNTeRNalleaKaGe(TypiCal)

peRmissiBleRaDialloaDpoweRlosshyDRomeChaNiCal(TypiCal)

60

65

70

75

80

0 40 80 120 160 200 240

Série1

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

600

1000

1400

1800

2200

2600

3000

3400

3800

600 1000 1400 1800 2200

Shaftkeyed

0

3

6

9

12

15

18

21

24

27

30

33

0 30 60 90 120 150 180 210 240

24 cSt10 cSt

P2

P2

P1

P1

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 2000 NTotal hydromechanical power loss is the sum of each section loss under its respective operating conditions.

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss under its respective operating conditions.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

Double pump noise level is given with both stages discharging at the pressure value indicated on the curve.

T7eD/T7eDs-orderingCode

01234567

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2200 RPM P1

P1

P1

P1 P2

0123456

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2200 RPM

P2

P2

P2

FaF

==

Shaft keyed N°1

Page 47: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

47 Parker HannifinDenison Vane Pump DivisionVierzon - France

T7eD/eDs-Dimensions-weight:66,0kg

213,0K

K/2

Ød

101,

681

,0

102,

489

,0

98,4

e x 45 °

2,3 x 45°

Ø S76

,2Ø

42,3

6M

AX

38,1

038

,05

Ø

SHAFT CODE 1 (Keyed SAE CC )

38,1

KEY 7,94 7,89

35,2

7M

AX

31,7

531

,70

Ø

2,3 x 45°

SHAFT CODE 2

P1SP2

35,717,8

77,838,9

30,215,1

69,8

130,

265

,1

58,7 29

,4

361,0

KEY 9,52 9,47

M10 x 20 DEEP

A x 23,4 DEEP - 4 HOLESB x 30 DEEP - 4 HOLES

Ø 37,10PRESSUREØ 101,60SUCTIONØ 31,80PRESSURE

55,9

7,9 38,1

2,3 x 45°

SHAFT CODE 3 SAE C INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 12/24 14 TEETH - 30° PRESSURE ANGLE

C x 24 DEEP - 4 HOLES

MOUNTING TORQUE : 187 Nm

148,2 133,5 52,3 W7,9

6,4 MAXI50,8

90,9

(Keyed no SAE )

62,2

7,9 31,5

2,3 x 45°

SHAFT CODE 4 SAE CC INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 12/24

17 TEETH - 30° PRESSURE ANGLE

MOUNTING TORQUE : 187 Nm

2,3 x 45 °

10,090,0

50,0

41,3

MA

XI

38,0

1838

,002

Ø

KEY 10 x 8

M10 x 20 DEEP

W

e x 45°

SHAFT CODE 5 ( Keyed ISO/R775 - G38M )

T7ED

T7EDS

Ø S

C.G.

161,0

61,9

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 240 bar p = 7 bar p = 140 bar p = 240 bar

P1

042 132,3 ml/rev 198,5 188,5 181,3 5,2 49,4 82,6

045 142,4 ml/rev 213,6 203,6 196,5 5,4 52,9 88,7

050 158,5 ml/rev 237,7 227,7 220,6 5,7 58,5 98,3

052 164,8 ml/rev 247,2 237,2 230,1 5,8 60,8 102,1

054 171,0 ml/rev 256,5 246,5 239,4 5,9 63,0 105,8

057 183,3 ml/rev 275,0 265,0 257,9 6,1 67,3 113,2

062 196,7 ml/rev 295,0 285,0 277,9 6,4 71,9 121,3

066 213,3 ml/rev 319,9 309,0 302,8 6,7 77,7 131,2

072 227,1 ml/rev 340,6 330,6 323,5 6,9 82,6 139,5

085 268,7 ml/rev 403,0 392,01) - 9,1 65,81) -

p = 0 bar p = 140 bar p = 250 bar p = 7 bar p = 140 bar p = 250 bar

P2

B14 44,0 ml/rev 66,0 59,4 54,2 1,5 16,6 29,0

B17 55,0 ml/rev 82,5 75,9 70,7 1,7 20,4 35,8

B20 66,0 ml/rev 99,0 92,4 87,2 1,9 24,3 42,7

B22 70,3 ml/rev 105,5 98,8 93,7 2,0 25,8 45,4

B24 81,1 ml/rev 121,7 115,0 109,9 2,2 29,5 52,1

B28 90,0 ml/rev 135,0 128,4 123,2 2,3 32,7 57,7

B31 99,2 ml/rev 148,8 142,2 137,0 2,5 35,9 63,5

B35 113,4 ml/rev 170,1 163,5 158,3 2,7 40,8 72,3

B38 120,6 ml/rev 180,9 174,3 169,1 2,9 43,4 76,8

B42 137,5 ml/rev 206,3 199,6 194,5 3,2 49,3 87,4

045 145,7 ml/rev 218,6 209,2 202,6 4,1 52,8 89,5

050 158,0 ml/rev 237,0 227,7 223,02) 4,4 57,1 85,02)

1) 085 = 90 bar max. int. 2) 050 = 210 bar max.int.

opeRaTiNGChaRaCTeRisTiCs-TypiCal[24cst]

Shaft torque limits [ml/rev. x bar]Shaft Vi x p max. Shaft Vi x p max.

1 72300 4 68500

2 34590 5 685003 61200

Alternate mounting flange

Dia Se x 45° W K Dia d

Max. Min.

T7ED 125,000 124,937 2,0 9,5 180,0 18,0

T7EDS 127,000 126,950 1,3 12,7 181,0 17,5

Alternate connect. variables01 M1

A 1/2" - 13 UNC M12B 5/8" - 11 UNC M16C 7/16" - 14 UNC M12

Page 48: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

48 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T7EE or T7EES - 066 - 045 - 1 R 00 - A 1 0 00 - ..T7EE series - 250 B4 HWISO 2 bolts 3019-2 mounting flangeT7EES series - SAE E 4 boltsJ744 mounting flange

Displacement P1 & P2Volumetric displacement (ml/rev.)042 = 132,3 057 = 183,3045 = 142,4 062 = 196,7050 = 158,5 066 = 213,3052 = 164,8 072 = 227,1054 = 171,0 085 = 268,7

Type of shaft T7EES1 = keyed (SAE CC) 4 = splined (SAE D & E) 13 teeth3 = splined (SAE CC) 17 teeth 5 = keyed (SAE D & E)

Type of shaft T7EE2 = keyed (ISO 3019-2 - G45N)

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

Modifications

Mounting w/connection variables4 bolts SAE flanges J518

P1 & P2 = 1.1/2" - S = 4"

T7EE - T7EES T7EES

Type Metric thread UNC thread

Code M0 00

Coupling adaptor0 = none2 = SAE B3 = SAE BB* for SAE C, please contact Parker Denison

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON® - 7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination (see page 72)00 = standard

Noiselevel(TypiCal)-T7ee-050-050iNTeRNalleaKaGe(TypiCal)

peRmissibleRadialloadpoweRlosshydRomeChaNiCal(TypiCal)

65

70

75

80

85

0 40 80 120 160 200 240

Série1Série2

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

600

1000

1400

1800

2200

2600

3000

3400

3800

600 1000 1400 1800 2200

Shaftkeyed

0

3

6

9

12

15

18

21

24

27

30

33

0 30 60 90 120 150 180 210 240

24 cSt10 cSt

P1-P2

P1-P2

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 2000 NTotal hydromechanical power loss is the sum of each section loss under its respective operating conditions.

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss under its respective operating conditions.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

Double pump noise level is given with both stages discharging at the pressure value indicated on the curve.

T7ee/T7ees-orderingCode

P1 P2

0

1

2

3

4

5

6

7

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2200 RPM

P1-P2

P1-P2

P1-P2

FaF

==

Shaft keyed N°1

Page 49: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

49 Parker HannifinDenison Vane Pump DivisionVierzon - France

T7ee/ees-dimensions-weight:95,0kg

100,08,0

63,5

KEY 11,11 11,06

49,3

MAX

44,4

544

,40

Ø

2,3 x 45°

92,010,0

63,0

48,5

MAX

45,0

0044

,975

Ø

250,

000

249,

928

Ø

3,0 x 45°

KEY 14 x 9

222,

7

22,0

Ø

22,0 9,0

1,5 x 45°

P2 S P1

427,8 62,2

8,0

2,3 x 45°

209

69,9

35,7

77,8

130,

2

69,9

146,

0Ø17

3,3

38,1PRESSURE Ø101,6SUCTION Ø

Ø 37,1PRESSURE

22,0 9,0

1,5 x 45°

90,942,9

165,

1016

5,05

Ø

42,3

6M

AX

38,1

0038

,075

Ø

M10 x 20 DEEP

63,5

KEY 9,52 9,47

SHAFT CODE 1(KEYED SAE C-C)

139,

710

4,5

86,6

98,4

101,

70 *

101,

65Ø

COUPLING ADAPTAT OR

15,5

MOUNTING TORQUE : 300 N.m

273,

0

273,0224,5 Ø 20.6

75,0

8,0

48,8

3,0 x 45°

MOUNTING TORQUE 88 N.mMOUNTING TORQUE 300 N.m

35,7

1/2-13 UNC x 30 DEEP - 4 HOLES(M12 x 30 - METRIC VERSION)5/8-11 UNC x 30 DEEP - 4 HOLES

(M16 x 30 - METRIC VERSION)

1/2-13 UNC x 23,4 DEEP - 4 HOLES(M12 x 23,4 - METRIC VERSION)

M12 x 28 DEEP

6,4

SHAFT CODE 5(KEYED SAE D & E)

SHAFT CODE 2(KEYED G45N-ISO 3019-2)

T7EE

SHAFT CODE 3 SAE CC SPLINED SHAFT

CLASS 1- J498b 12/24 D.P. - 17 TEETH

30° PRESSURE ANGLE FLAT ROOT SIDE FIT

SHAFT CODE 4 SAE D & E SPLINED SHAFT

CLASS 1- J498b 8/16 D.P. - 13 TEETH

30° PRESSURE ANGLE FLAT ROOT SIDE FIT

M12 x 24 DEEP

8,0

406,8

846

224,

5

1/2-13 UNC x 2 4 DEEP

167,3157,9

115

118

C.G.

170,0

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 240 bar p = 7 bar p = 140 bar p = 240 bar

P1

&

P2

042 132,3 ml/rev 198,5 188,5 181,3 5,2 49,4 82,6

045 142,4 ml/rev 213,6 203,6 196,5 5,4 52,9 88,7

050 158,5 ml/rev 237,7 227,7 220,6 5,7 58,5 98,3

052 164,8 ml/rev 247,2 237,2 230,1 5,8 60,8 102,1

054 171,0 ml/rev 256,5 246,5 239,4 5,9 63,0 105,8

057 183,3 ml/rev 275,0 265,0 257,9 6,1 67,3 113,2

062 196,7 ml/rev 295,0 285,0 277,9 6,4 71,9 121,3

066 213,3 ml/rev 319,9 309,0 302,8 6,7 77,7 131,2

072 227,1 ml/rev 340,6 330,6 323,5 6,9 82,6 139,5

085 268,7 ml/rev 403,0 392,01) - 9,1 65,81) -1) 085 = 90 bar max. int.* For SAE C, please contact Parker Denison.

opeRaTiNGChaRaCTeRisTiCs-TypiCal[24cst]

Shaft torque limits [ml/rev. x bar]Shaft Vi x p max. Coupling drive Vi x p max.

1 90380 SAE B 206002 114600 SAE BB 32670

3 126800

4 1268005 118340

Code Coupling adaptor0 Without coupling

2SAE B - 13 teeth - Pitch 16/32

Major dia. (min) 22,225 - Minor dia. (min) 19,134

3SAE BB - 15 teeth - Pitch 16/32

Major dia. (min.) 25,400 - Minor dia. (min.) 22,268

Page 50: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

50 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T7DBB or T7DBBS - B38 - B14 - B08 - 1 R 00 - A 1 - M1 - ..

T7DBB series - 125-A2-HWISO 4 bolts 3019-2 mounting flange

T7DBBS series - SAE C 6 boltsJ744 mounting flange

Displacement for “P1”Volumetric displacement (ml/rev)B14 = 44,0 B31 = 99,2B17 = 55,0 B35 = 113,4B20 = 66,0 B38 = 120,6B22 = 70,3 B42 = 137,5B24 = 81,1 045 = 145,7B28 = 90,0 050 = 158,0

Displacement for “P2” & “P3”Volumetric displacement (ml/rev)B02 = 5,8 B09 = 28,0B03 = 9,8 B10 = 31,8B04 = 12,8 B11 = 35,0B05 = 15,9 B12 = 41,0B06 = 19,8 B14 = 45,0B07 = 22,5 B15 = 50,0B08 = 24,9

Type of shaft T7DBBS1 = keyed (non SAE)2 = keyed (SAE CC)3 = splined 12/24 (SAE C) (14 teeth)4 = splined 12/24 (SAE CC) (17 teeth)

Type of shaft T7DBB & T7DBBS5 = keyed (ISO 3019/2 - G38M)

Modifications

Mounting w/connection variables4 bolts SAE flange J518

P1 = 1.1/4" - P2 = 1" - S = 4"

Metric thread

UNC thread

T7DBB-P3 = 3/4" M1

T7DBBS-P3 = 3/4" M1 01

T7DBB-P3 = 1" M0

T7DBBS-P3 = 1" M0 00

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON® - 7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination (see pages 72 - 73)00 = standard

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

T7DBB/T7DBBS-OrderingCode

P1 P2 P3

OperaTingCharaCTeriSTiCS-TypiCal[24cSt]

1) 050 = 210 bar max. int. 2) B15 = 280 bar max.int.

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 250 bar p = 7 bar p = 140 bar p = 250 bar

P1

B14 44,0 ml/rev 66,0 59,4 54,2 1,5 16,6 29,0

B17 55,0 ml/rev 82,5 75,9 70,7 1,7 20,4 35,8

B20 66,0 ml/rev 99,0 92,4 87,2 1,9 24,3 42,7

B22 70,3 ml/rev 105,5 98,8 93,7 2,0 25,8 45,4

B24 81,1 ml/rev 121,7 115,0 109,9 2,2 29,5 52,1

B28 90,0 ml/rev 135,0 128,4 123,2 2,3 32,7 57,7

B31 99,2 ml/rev 148,8 142,2 137,0 2,5 35,9 63,5

B35 113,4 ml/rev 170,1 163,5 158,3 2,7 40,8 72,3

B38 120,6 ml/rev 180,9 174,3 169,1 2,9 43,4 76,8

B42 137,5 ml/rev 206,3 199,6 194,5 3,2 49,3 87,4

045 145,7 ml/rev 218,6 209,2 202,6 4,1 52,8 89,5

050 158,0 ml/rev 237,0 227,7 223,01) 4,4 57,1 85,01)

p = 0 bar p = 140 bar p = 300 bar p = 7 bar p = 140 bar p = 300 bar

P2

&

P3

B02 5,8 ml/rev 8,7 7,0 5,1 0,5 2,6 5,1

B03 9,8 ml/rev 14,7 13,0 11,1 0,6 4,0 8,1

B04 12,8 ml/rev 19,2 17,5 15,6 0,6 5,0 10,4

B05 15,9 ml/rev 23,9 22,2 20,2 0,7 6,1 12,7

B06 19,8 ml/rev 29,7 28,0 26,1 0,7 7,5 15,6

B07 22,5 ml/rev 33,7 32,0 30,2 0,8 8,5 17,6

B08 24,9 ml/rev 37,4 35,7 33,7 0,8 9,3 19,5

B09 28,0 ml/rev 42,0 40,3 38,4 0,9 10,4 21,8

B10 31,8 ml/rev 47,7 46,0 44,1 0,9 11,7 26,2

B11 35,0 ml/rev 52,5 50,8 48,9 1,0 12,8 27,0

B12 41,0 ml/rev 61,5 59,8 57,9 1,1 14,9 31,5

B14 45,0 ml/rev 67,5 65,8 63,9 1,2 16,3 34,5

B15 50,0 ml/rev 75,0 73,3 71,62) 1,3 18,1 35,72)

Page 51: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

51 Parker HannifinDenison Vane Pump DivisionVierzon - France

nOiSelevel(TypiCal)-T7DBB-B38-B06-B04inTernalleaKage(TypiCal)

permiSSiBleraDiallOaDpOwerlOSShyDrOmeChaniCal(TypiCal)

55

60

65

70

75

0 40 80 120 160 200 240

Série1

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

200

400

600

800

1000

1200

1400

1600

1800

600 900 1200 1500 1800 2100 2400

Shaftkeyed

0

2

4

6

8

10

12

14

16

18

20

22

0 50 100 150 200 250 300

24 cSt10 cSt

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 1200 NTotal hydromechanical power loss is the sum of each section loss under its respective operating conditions.

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss under its respective operating conditions.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

Triple pump noise level is given with all stages discharging at the pressure value indicated on the curve.

0

1

2

3

4

5

6

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2500 RPM

0

0,5

1

1,5

2

2,5

3

3,5

0 50 100 150 200 250 300

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2500 RPM

P2-P3

P1

P1

P3-P3

P2-P3

P1

P1

P2-P3

P1

P2-P3

T7DBB/T7DBBS-Technicaldata

FaF

==

Shaft keyed N°1

Page 52: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

52 Parker HannifinDenison Vane Pump DivisionVierzon - France

T7DBB/S-DCB/S-DCC/S-Dimensions-weight:61kg

P3

P2

SP

1

127,0

421,

856

101,6

75,5 74,0

101,6

K1

213,

1

7,9

6,35

MAX

I

30,2

58,7

38,1

138

122,

499

,5

64,3 Ø

Ø S

e x

45°

2,3

x 45

°

77,8

130,2

26,2

52,4

B

A

SH

AFT

CO

DE

3 S

AE C

INVO

LUTE

SP

LIN

E D

ATA

CLA

SS 1

-FLA

T R

OO

T SI

DE

FIT

J49

8b -

PITC

H 1

2/24

14

TEET

H -

30°

PRE

SSU

RE

AN

GLE

MO

UN

TIN

G T

OR

QU

E :

68 N

mM

OU

NTI

NG

TO

RQ

UE

: 187

Nm

7/16

-14

UN

C x

22,

3 D

EEP

- 4 H

OLE

SM

12 x

22,

3 D

EEP

- M

ETR

IC V

ERS

ION

5/8-

11 U

NC

x 3

0 D

EEP

- 4

HO

LES

M16

x 3

0 D

EEP

- ME

TRIC

VE

RS

ION

3/8-

16 U

NC

x 1

9 D

EEP

- 4

HO

LES

M10

x 1

9 D

EEP

- M

ETR

IC V

ER

SIO

N

3/8-

16 U

NC

x 1

9 D

EEP

- 4 H

OLE

SM

10 x

19

DE

EP

- MET

RIC

VER

SIO

N

PR

ESS

UR

E Ø

31,

8S

UC

TIO

N Ø

101

,6PR

ESSU

RE

Ø 2

5,4

PRES

SUR

E Ø

C

38

95,6

M10

x20

DEE

P42,3MAXI

38,10038,075 Ø

2,3

x 45

°

SH

AFT

CO

DE

2

61,0

7,9

31,5

2,3

x 45

°

SH

AFT

CO

DE

4SA

E C

C IN

VOLU

TE S

PLIN

E D

ATA

CLA

SS 1

-FLA

T R

OO

T S

IDE

FIT

J49

8b -

PITC

H 1

6/32

17 T

EET

H -

30°

PRES

SUR

E AN

GLE

1984

49,3

7,9

SH

AFT

CO

DE

1

63,5

89,7

7,9

2,3

x 45

°31,750

-0.05 Ø

34,6MAXI

KE

Y 6,

356,

30

91,0

KEY

9,5

2

9

,47

w

SH

AFT

CO

DE

5K

eyed

ISO

R77

5 - G

38M

KE

Y 10

x 8

50,0

10,068

,0

M10

x20

DEE

P

189,

0

5,4

38,01838,002

41,0MAXI

K2

K2

Ø d1

?Ø d2

Key

ed S

AE C

CKe

yed

no S

AE

Ø

Shaf

t to

rque

lim

its

[ml/r

ev. x

bar

]Sh

aft

Vi x

p m

ax. P

1 +

P2

+ P

3Sh

aft

Vi x

p m

ax. P

1 +

P2

+ P

31

4324

04

8340

02

7175

05

5650

03

6120

0

Alt

erna

te m

ount

ing

flang

e

Seri

esD

ia S

e x

45°

WK

1D

ia d

1K

2D

ia d

2M

ax.

Min

.

T7D

BB

- T

7DC

B -

T7D

CC

125,

000

124,

937

2,0

9,5

180,

018

,011

3,14

14,0

T7D

BB

S - T

7DC

BS

- T7D

CC

S12

7,00

012

6,95

01,

312

,718

1,0

17,5

114,

5014

,3

Alt

erna

te c

onne

ct. v

aria

bles

00 &

M0

01 &

M1

A52

,447

,6

B26

,222

,2

C25

,419

,0

Page 53: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

53 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T7DCB or T7DCBS - B38 - 028 - B08 - 1 R 00 - A 1 - M1 - ..T7DCB series - 125-A2-HWISO 4 bolts 3019-2 mounting flange

T7DCBS series - SAE C 2 boltsJ744 mounting flange

Displacement for “P1”Volumetric displacement (ml/rev)B14 = 44,0 B24 = 81,1 B38 = 120,6B17 = 55,0 B28 = 90,0 B42 = 137,5B20 = 66,0 B31 = 99,2 045 = 145,7B22 = 70,3 B35 = 113,4 050 = 158,0

Displacement for “P2”Volumetric displacement (ml/rev)003 = 10,8 012 = 37,1 022 = 70,3005 = 17,2 014 = 46,0 025 = 79,3006 = 21,3 017 = 58,3 028 = 88,8008 = 26.4 020 = 63,8 031 = 100,0010 = 34,1

Displacement for “P3”Volumetric displacement (ml/rev)B02 = 5,8 B07 = 22,5 B12 = 41,0B03 = 9,8 B08 = 24,9 B14 = 45,0B04 = 12,8 B09 = 28,0 B15 = 50,0B05 = 15,9 B10 = 31,8B06 = 19,8 B11 = 35,0

Modifications

Mounting w/connection variables4 bolts SAE flange J518

P1 = 1.1/4 " - P2 = 1" - S = 4"Metric thread UNC thread

T7DCB-P3 = 3/4" M1T7DCBS-P3 = 3/4" M1 01

T7DCB-P3 = 1" M0T7DCBS-P3 = 1" M0 00

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON - 7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination (see pages 72 - 73)00 = standard

Direction of rotation (shaft end view)R = Clockwise L = Counter-clockwise

Type of shaft T7DCBS1 = keyed (non SAE)2 = keyed (SAE CC)3 = splined 12/24 (SAE C) (14 teeth)4 = splined 12/24 (SAE CC) (17 teeth)

T7DCB/T7DCBS-OrderingCode

P1 P2 P3

OperaTingCharaCTeriSTiCS-TypiCal[24cSt]Pressure

port Series Vi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 250 bar p = 7 bar p = 140 bar p = 250 bar

P1

B14 44,0 ml/rev 66,0 59,4 54,2 1,5 16,6 29,0B17 55,0 ml/rev 82,5 75,9 70,7 1,7 20,4 35,8B20 66,0 ml/rev 99,0 92,4 87,2 1,9 24,3 42,7B22 70,3 ml/rev 105,5 98,8 93,7 2,0 25,8 45,4B24 81,1 ml/rev 121,7 115,0 109,9 2,2 29,5 52,1B28 90,0 ml/rev 135,0 128,4 123,2 2,3 32,7 57,7B31 99,2 ml/rev 148,8 142,2 137,0 2,5 35,9 63,5B35 113,4 ml/rev 170,1 163,5 158,3 2,7 40,8 72,3B38 120,6 ml/rev 180,9 174,3 169,1 2,9 43,4 76,8B42 137,5 ml/rev 206,3 199,6 194,5 3,2 49,3 87,4045 145,7 ml/rev 218,6 209,2 202,6 4,1 52,8 89,5050 158,0 ml/rev 237,0 227,7 223,01) 4,4 57,1 85,01)

p = 0 bar p = 140 bar p = 275 bar p = 7 bar p = 140 bar p = 275 bar

P2

003 10,8 ml/rev 16,2 11,2 * 1,3 5,3 *005 17,2 ml/rev 25,8 20,8 16,1 1,4 7,5 13,9006 21,3 ml/rev 31,9 26,9 22,2 1,5 8,9 16,8008 26,4 ml/rev 39,6 34,6 29,9 1,6 10,7 20,3010 34,1 ml/rev 51,1 46,1 41,4 1,7 13,4 25,6012 37,1 ml/rev 55,6 50,6 45,9 1,7 14,4 27,6014 46,0 ml/rev 69,0 64,0 59,3 1,9 17,6 33,7017 58,3 ml/rev 87,4 82,4 77,7 2,1 21,9 42,2020 63,8 ml/rev 95,7 90,7 86,0 2,2 23,8 46,0022 70,3 ml/rev 105,4 100,4 95,7 2,3 26,1 50,4025 79,3 ml/rev 118,9 113,9 109,2 2,5 29,2 56,6028 88,8 ml/rev 133,2 128,2 125,81) 2,8 32,7 48,51)

031 100,0 ml/rev 150,0 145,0 142,61) 2,8 36,5 54,41)

p = 0 bar p = 140 bar p = 300 bar p = 7 bar p = 140 bar p = 300 bar

P3

B02 5,8 ml/rev 8,7 7,0 5,1 0,5 2,6 5,1B03 9,8 ml/rev 14,7 13,0 11,1 0,6 4,0 8,1B04 12,8 ml/rev 19,2 17,5 15,6 0,6 5,0 10,4B05 15,9 ml/rev 23,9 22,2 20,2 0,7 6,1 12,7B06 19,8 ml/rev 29,7 28,0 26,1 0,7 7,5 15,6B07 22,5 ml/rev 33,7 32,0 30,2 0,8 8,5 17,6B08 24,9 ml/rev 37,4 35,7 33,7 0,8 9,3 19,5B09 28,0 ml/rev 42,0 40,3 38,4 0,9 10,4 21,8B10 31,8 ml/rev 47,7 46,0 44,1 0,9 11,7 26,2B11 35,0 ml/rev 52,5 50,8 48,9 1,0 12,8 27,0B12 41,0 ml/rev 61,5 59,8 57,9 1,1 14,9 31,5B14 45,0 ml/rev 67,5 65,8 63,9 1,2 16,3 34,5B15 50,0 ml/rev 75,0 73,3 71,62) 1,3 18,1 35,72)

Type of shaft T7DCB & T7DCBS5 = keyed (ISO 3019/2 - G38M)

* We do not recommand to use the size 003 in P2 at 275 bar & 1500 RPM as the internal leakage is over 50% of theoretical flow.1) 050 - 028 - 031 = 210 bar max. int. 2) B15 = 280 bar max. int.

Page 54: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

54 Parker HannifinDenison Vane Pump DivisionVierzon - France

nOiSelevel(TypiCal)-T7DCB-B38-022-B10inTernalleaKage(TypiCal)

permiSSiBleraDiallOaDpOwerlOSShyDrOmeChaniCal(TypiCal)

60

65

70

75

80

0 40 80 120 160 200 240

Série1

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

200

400

600

800

1000

1200

1400

1600

1800

600 900 1200 1500 1800 2100 2400

Shaftkeyed

0

2

4

6

8

10

12

14

16

18

20

22

0 50 100 150 200 250 300

24 cSt10 cSt

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 800 NTotal hydromechanical power loss is the sum of each section loss under its respective operating conditions.

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss under its respective operating conditions.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

Triple pump noise level is given with all stages discharging at the pressure value indicated on the curve.

0123456

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2500 RPM

0

1

2

3

0 50 100 150 200 250 300

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2500 RPM

P1

P3

P3

P2

P1

P1

P1

P2-P3

T7DCB/T7DCBS-Technicaldata

P1 P2

0

1

2

3

4

0 40 80 120 160 200 240 280

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2500 RPM P2

P2

P2

P3

P3

P3

FaF

==

Shaft keyed N°1

Page 55: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

55 Parker HannifinDenison Vane Pump DivisionVierzon - France

Noiselevel(TypiCal)-T7DCC-B31-022-022iNTeRNalleaKaGe(TypiCal)

60

65

70

75

80

0 40 80 120 160 200 240

Série1

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

200

400

600

800

1000

1200

1400

1600

1800

600 900 1200 1500 1800 2100 2400

Shaftkeyed

0

2

4

6

8

10

12

14

16

18

20

22

0 40 80 120 160 200 240 280

24 cSt10 cSt

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 1200 NTotal hydromechanical power loss is the sum of each section loss under its respective operating conditions.

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss under its respective operating conditions.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

Triple pump noise level is given with all stages discharging at the pressure value indicated on the curve.

0

1

2

3

4

5

6

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2500 RPM

00,5

11,5

22,5

33,5

0 40 80 120 160 200 240 280

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2500 RPM

P1

P1

P1

P1

P2-P3

T7DCC/T7DCCs-Technicaldata

P1

P2-P3

P2-P3

P2-P3

P2-P3

peRmissiBleRaDialloaDpoweRlosshyDRomeChaNiCal(TypiCal)

FaF

==

Shaft keyed N°1

Page 56: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

56 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T7DCC or T7DCCS - B38 - 028 - 010 - 5 R 00 - A 1 - M0 - ..

T7DCC series - 125-A2-HWISO 2 bolts 3019-2 mounting flange

T7DCCS series - SAE C 2 boltsJ744 mounting flange

Displacement for “P1”Volumetric displacement (ml/rev)B14 = 44,0 B31 = 99,2B17 = 55,0 B35 = 113,4B20 = 66,0 B38 = 120,6B22 = 70,3 B42 = 137,5B24 = 81,1 045 = 145,7B28 = 90,0 050 = 158,0

Displacement for “P2” & P3Volumetric displacement (ml/rev)003 = 10,8 017 = 58,3005 = 17,2 020 = 63,8006 = 21,3 022 = 70,3008 = 26.4 025 = 79,3010 = 34,1 028 = 88,8012 = 37,1 031 = 100,0014 = 46,0

Type of shaft T7DCCS1 = keyed (non SAE)2 = keyed (SAE CC)3 = splined 12/24 (SAE C)4 = splined 12/24 (SAE CC)

Type of shaft T7DCC & T7DCCS5 = keyed (ISO 3019/2 - G38M)

Modifications

Mounting w/connection variables4 bolts SAE flange J518

P1 = 1.1/4" - P2 = 1" - S = 4"

Metric thread

UNC thread

T7DCC-P3 = 3/4" M1

T7DCCS-P3 = 3/4" M1 01

T7DCC-P3 = 1" M0

T7DCCS-P3 = 1" M0 00

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON® - 7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination (see pages 72 - 73)00 = standard

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

T7DCC/T7DCCs-orderingCode

P1 P2 P3

opeRaTiNGChaRaCTeRisTiCs-TypiCal[24cst]Pressure

portSeries

Vi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 250 bar p = 7 bar p = 140 bar p = 250 bar

P1

B14 44,0 ml/rev 66,0 59,4 54,2 1,5 16,6 29,0

B17 55,0 ml/rev 82,5 75,9 70,7 1,7 20,4 35,8

B20 66,0 ml/rev 99,0 92,4 87,2 1,9 24,3 42,7

B22 70,3 ml/rev 105,5 98,8 93,7 2,0 25,8 45,4

B24 81,1 ml/rev 121,7 115,0 109,9 2,2 29,5 52,1

B28 90,0 ml/rev 135,0 128,4 123,2 2,3 32,7 57,7

B31 99,2 ml/rev 148,8 142,2 137,0 2,5 35,9 63,5

B35 113,4 ml/rev 170,1 163,5 158,3 2,7 40,8 72,3

B38 120,6 ml/rev 180,9 174,3 169,1 2,9 43,4 76,8

B42 137,5 ml/rev 206,3 199,6 194,5 3,2 49,3 87,4

045 145,7 ml/rev 218,6 209,2 202,6 4,1 52,8 89,5

050 158,0 ml/rev 237,0 227,7 223,01) 4,4 57,1 85,01)

p = 0 bar p = 140 bar p = 275 bar p = 7 bar p = 140 bar p = 275 bar

P2

&

P3

003 10,8 ml/rev 16,2 11,2 * 1,3 5,3 *

005 17,2 ml/rev 25,8 20,8 16,1 1,4 7,5 13,9

006 21,3 ml/rev 31,9 26,9 22,2 1,5 8,9 16,8

008 26,4 ml/rev 39,6 34,6 29,9 1,6 10,7 20,3

010 34,1 ml/rev 51,1 46,1 41,4 1,7 13,4 25,6

012 37,1 ml/rev 55,6 50,6 45,9 1,7 14,4 27,6

014 46,0 ml/rev 69,0 64,0 59,3 1,9 17,6 33,7

017 58,3 ml/rev 87,4 82,4 77,7 2,1 21,9 42,2

020 63,8 ml/rev 95,7 90,7 86,0 2,2 23,8 46,0

022 70,3 ml/rev 105,4 100,4 95,7 2,3 26,1 50,4

025 79,3 ml/rev 118,9 113,9 109,2 2,5 29,2 56,6

028 88,8 ml/rev 133,2 128,2 125,81) 2,8 32,7 48,51)

031 100,0 ml/rev 150,0 145,0 142,61) 2,8 36,5 54,41)

* We do not recommand to use the size 003 in P2 and P3 at 275 bar & 1500 RPM as the internal leakage is over 50% of theoretical flow.1) 050 - 028 - 031 = 210 bar max. int.

Page 57: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

57 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T7DDB or T7DDBS - 050 - B22 - B12 - 1 R 00 - A 1 - M0 - ..

T7DDB series - 125-B4-HWISO 4 bolts 3019-2 mounting flange

T7DDBS series - SAE C 6 boltsJ744 mounting flange

Displacement for “P1” & "P2"Volumetric displacement (ml/rev)B14 = 44,0 B31 = 99,2B17 = 55,0 B35 = 113,4B20 = 66,0 B38 = 120,6B22 = 70,3 B42 = 137,5B24 = 81,1 045 = 145,7B28 = 90,0 050 = 158,0

Displacement for “P3”Volumetric displacement (ml/rev)B02 = 5,8 B09 = 28,0B03 = 9,8 B10 = 31,8B04 = 12,8 B11 = 35,0B05 = 15,9 B12 = 41,0B06 = 19,8 B14 = 45,0B07 = 22,5 B15 = 50,0B08 = 24,9

Type of shaft T7DDBS1 = keyed (SAE C)2 = keyed (SAE CC)3 = splined 12/24 (SAE C) (14 teeth)4 = splined 12/24 (SAE CC) (17 teeth)

Type of shaft T7DBB & T7DBBS5 = keyed (ISO 3019/2 - G38M)

Modifications

Mounting w/connection variables4 bolts SAE flange J518

P1 & P2 = 1.1/4" - S = 4"

Metric thread

UNC thread

T7DDB-P3 = 1" M0

T7DDB-P3 = 3/4" M1

T7DDBS-P3 = 1" M0 00

T7DDBS-P3 = 3/4" M1 01

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON® - 7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination (see pages 72 - 73)00 = standard

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

T7DDB/T7DDBS-OrderingCode

P1 P2 P3

OperaTingCharaCTeriSTiCS-TypiCal[24cSt]

1) 050 = 210 bar max. int. 2) B15 = 280 bar max.int.

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 250 bar p = 7 bar p = 140 bar p = 250 bar

P1

&

P2

B14 44,0 ml/rev 66,0 59,4 54,2 1,5 16,6 29,0

B17 55,0 ml/rev 82,5 75,9 70,7 1,7 20,4 35,8

B20 66,0 ml/rev 99,0 92,4 87,2 1,9 24,3 42,7

B22 70,3 ml/rev 105,5 98,8 93,7 2,0 25,8 45,4

B24 81,1 ml/rev 121,7 115,0 109,9 2,2 29,5 52,1

B28 90,0 ml/rev 135,0 128,4 123,2 2,3 32,7 57,7

B31 99,2 ml/rev 148,8 142,2 137,0 2,5 35,9 63,5

B35 113,4 ml/rev 170,1 163,5 158,3 2,7 40,8 72,3

B38 120,6 ml/rev 180,9 174,3 169,1 2,9 43,4 76,8

B42 137,5 ml/rev 206,3 199,6 194,5 3,2 49,3 87,4

045 145,7 ml/rev 218,6 209,2 202,6 4,1 52,8 89,5

050 158,0 ml/rev 237,0 227,7 223,01) 4,4 57,1 85,01)

p = 0 bar p = 140 bar p = 300 bar p = 7 bar p = 140 bar p = 300 bar

P3

B02 5,8 ml/rev 8,7 7,0 5,1 0,5 2,6 5,1

B03 9,8 ml/rev 14,7 13,0 11,1 0,6 4,0 8,1

B04 12,8 ml/rev 19,2 17,5 15,6 0,6 5,0 10,4

B05 15,9 ml/rev 23,9 22,2 20,2 0,7 6,1 12,7

B06 19,8 ml/rev 29,7 28,0 26,1 0,7 7,5 15,6

B07 22,5 ml/rev 33,7 32,0 30,2 0,8 8,5 17,6

B08 24,9 ml/rev 37,4 35,7 33,7 0,8 9,3 19,5

B09 28,0 ml/rev 42,0 40,3 38,4 0,9 10,4 21,8

B10 31,8 ml/rev 47,7 46,0 44,1 0,9 11,7 26,2

B11 35,0 ml/rev 52,5 50,8 48,9 1,0 12,8 27,0

B12 41,0 ml/rev 61,5 59,8 57,9 1,1 14,9 31,5

B14 45,0 ml/rev 67,5 65,8 63,9 1,2 16,3 34,5

B15 50,0 ml/rev 75,0 73,3 71,62) 1,3 18,1 35,72)

Page 58: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

58 Parker HannifinDenison Vane Pump DivisionVierzon - France

nOiSelevel(TypiCal)-T7DDB-B31-B31-B10inTernalleaKage(TypiCal)

permiSSiBleraDiallOaDpOwerlOSShyDrOmeChaniCal(TypiCal)

60

65

70

75

80

0 40 80 120 160 200 240

Série1

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

400

600

800

1000

1200

1400

1600

1800

2000

600 900 1200 1500 1800 2100 2400

Shaftkeyed

0

2

4

6

8

10

12

14

16

18

20

22

0 50 100 150 200 250 300

24 cSt10 cSt

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 1200 NTotal hydromechanical power loss is the sum of each section loss under its respective operating conditions.

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss under its respective operating conditions.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

= =

FFa

FaF

==

Shaft keyed N°1

u

Triple pump noise level is given with all stages discharging at the pressure value indicated on the curve.

0

1

2

3

4

5

6

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2500 RPM

0

0,5

1

1,5

2

2,5

3

3,5

0 50 100 150 200 250 300

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2500 RPM

P1-P2

P3

P3

P1-P2

P1-P2

P3

P3

P1-P2

P3

P1-P2

T7DDB/T7DDBS-Technicaldata

FaF

==

Shaft keyed N°1

Page 59: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

59 Parker HannifinDenison Vane Pump DivisionVierzon - France

T7DDB/DDBS-Dimensions-weight:66kg

P1P2

P3S

P1P2

P3

S62

,07,

931

,52,

3x

45°

Ø d2

K2

213,

0

K1

K2

101,6 91,2

74,7

455,

0

120,

012

5,0

148,

538

,1W 7,

9

6,4

MAX

I

Ø S64,3 Ø

35,27MAXI

31,7531,70 Ø

M10 x 20 DEEP

2,3

x 45

°

ex

45°

19,0

MO

UN

TIN

G T

OR

QU

E :

80 N

m

114,9

56,0

7,9

6,4

MA

XI

38,0

2,3

x 45

°

58,7

30,2

77,8

130,2

30,2

58,7

182,2

A

B

PR

ES

SU

RE

Ø C

PR

ES

SU

RE

Ø 3

1,8

SU

CTI

ON

Ø 1

01,6

PR

ES

SU

RE

Ø 3

1,8

3/8-

16U

NC

x 1

9 D

EEP

M10

x 1

9 D

EE

P-M

ETR

IC V

ER

SIO

N7/

16-1

4UN

C x

24

DE

EP

M12

x 2

4 D

EE

P-M

ETR

IC V

ERSI

ON

5/8-

11U

NC

x 3

0 D

EEP

M16

x 3

0 D

EE

P-M

ETR

IC V

ERSI

ON

7/16

-14U

NC

x 2

2,3

DEE

PM

12 x

22,

3 D

EE

P-M

ETR

IC V

ERSI

ON

91,0

7,9

50,8

2,3

x 45

°

42,36MAXI

38,10Ø 38,05

M10 x 20 DEEP

KE

Y 9,

52

9,4

7

Ø d1

SH

AFT

CO

DE

2 K

eyed

SA

E C

C

SH

AFT

CO

DE

1K

eyed

SA

E C

SH

AFT

CO

DE

4 S

AE

CC

INV

OLU

TE S

PLI

NE

DAT

A C

LAS

S 1

-FLA

T R

OO

T S

IDE

FIT

J49

8b -

PIT

CH

12/

2417

TE

ETH

- 30

° PR

ESSU

RE

AN

GLE

SH

AFT

CO

DE

3 S

AE

C IN

VO

LUTE

SP

LIN

E D

ATA

CLA

SS

1-F

LAT

RO

OT

SID

E F

IT J

498b

- P

ITC

H 1

2/24

14

TEE

TH -

30°

PRES

SUR

E A

NG

LE

84,0 49

,3K

EY

7,94

7

,89

M10 x 20 DEEP

SH

AFT

CO

DE

5

KE

Y 1

0 x

8

10,0

Key

ed IS

O R

775

-G38

M

38,018Ø 38,002

41,0MAXI

50,0

68,0

MO

UN

TIN

G T

OR

QU

E :

190 N

mM

OU

NTI

NG

TO

RQ

UE

: 19

0 N

m

101,6

C.G

.

206,

5

Shaf

t to

rque

lim

its

[ml/r

ev. x

bar

]Sh

aft

Vi x

p m

ax. P

1 +

P2

+ P

3Sh

aft

Vi x

p m

ax. P

1 +

P2

+ P

31

4324

04

6650

02

7230

65

5310

03

6120

0

Alt

erna

te m

ount

ing

flang

e

Seri

esD

ia S

e x

45°

WK

1D

ia d

1K

2D

ia d

2M

ax.

Min

.

T7D

DB

125,

000

124,

937

2,0

9,5

180,

018

,011

3,14

14,0

T7D

DB

S12

7,00

012

6,95

01,

512

,718

1,0

17,5

114,

5014

,3

Alt

erna

te c

onne

ct. v

aria

bles

00 &

M0

01 &

M1

A52

,447

,6

B26

,222

,2

C25

,419

,0

Page 60: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

60 Parker HannifinDenison Vane Pump DivisionVierzon - France

T67DDCS-Dimensions-Weight:66kg

P1P2

P3S

P1

P2

P3

S62

,07,

931

,52,

3x

45°

14,3 114,5

213,

0

181,

0

114,

5

101,6 91,2

74,7

455,

0

120,

012

5,0

148,

538

,112

,77,

9

6,4

MAX

I

127,00126,95 Ø

64,3 Ø

35,27MAXI

31,7531,70 Ø

M10 x 20 DEEP

2,3

x 45

°

1,3

x 45

°

19,0

MO

UN

TIN

G T

OR

QU

E :

80 N

m

MO

UN

TIN

G T

OR

QU

E :

190

Nm

MO

UN

TIN

G T

OR

QU

E :

190

Nm

115,0

56,0

7,9

6,4

MAX

I

37,7

2,3

x 45

°

58,7

30,2

77,8

130,2

30,2

58,7

182,2

A

B

PR

ES

SU

RE

Ø

C31

,8P

RE

SS

UR

E Ø

Ø10

1,6

SU

CTI

ON

31,8

PR

ES

SU

RE

Ø

3/8-

16U

NC

x 19

DE

EP

M10

x 1

9 D

EE

P-M

ETR

IC V

ERS

ION

7/16

-14U

NC

x 24

DE

EP

M12

x 2

4 D

EE

P-M

ETR

IC V

ER

SIO

N5/

8-11

UN

C x

30

DE

EP

M16

x 3

0 D

EE

P-M

ETR

IC V

ER

SIO

N7/

16-1

4UN

C x

22,3

DE

EP

M12

x 2

2,3

DE

EP-

ME

TRIC

VER

SIO

N

91,0

7,9

50,8

2,3

x 45

°

42,36MAXI

38,1038,05 Ø

M10 x 20 DEEP

KE

Y 9,

52

9

,47

7,984

,0 59,6

2,3

x 45

°

KE

Y 7.

94

7

.89

38,42MAXI

34,9034,85 Ø

M10 x 20 DEEP

17,5 Ø

SH

AFT

CO

DE

5 (K

EYE

D N

O S

AE)

SH

AFT

CO

DE

2 (

KEY

ED

SA

E C

C )

SH

AFT

CO

DE

1 (

KE

YED

SA

E C

)

SH

AFT

CO

DE

4 S

AE

CC

INV

OLU

TE S

PLI

NE

DAT

A C

LAS

S 1

-FLA

T R

OO

T S

IDE

FIT

J49

8b -

PIT

CH

12/

24 1

7 TE

ETH

- 30

° P

RE

SSU

RE

AN

GLE

SH

AFT

CO

DE

3 S

AE

C IN

VOLU

TE S

PLI

NE

DAT

A C

LAS

S 1

-FLA

T R

OO

T S

IDE

FIT

J49

8b -

PIT

CH

12/

24 1

4 TE

ETH

- 30

° P

RE

SSU

RE

AN

GLE

84,0 49

,3

KE

Y 7,

94

7

,89

101,6

C.G

.

206,

5

Shaf

t to

rque

lim

its

[ml/r

ev. x

bar

]Sh

aft

Vi x

p m

ax. P

1 +

P2

+ P

3Sh

aft

Vi x

p m

ax. P

1 +

P2

+ P

31

4324

04

6650

02

7230

65

5560

03

6120

0

Alt

erna

te c

onne

ct. v

aria

bles

00 &

M0

01 &

M1

A52

,447

,6

B26

,222

,2

C25

,419

,0

Page 61: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

61 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T67DDCS - 050 - B35 - B08 - 1 R 00 - A 1 - M0 - ..

Series - SAE C 6 boltsJ744 mounting flange

Displacement for “P1” & "P2"Volumetric displacement (ml/rev)B14 = 44,0 B31 = 99,2B17 = 55,0 B35 = 113,4B20 = 66,0 B38 = 120,6B22 = 70,3 B42 = 137,5B24 = 81,1 045 = 145,7B28 = 90,0 050 = 158,0

Displacement for “P3”Volumetric displacement (ml/rev)003 = 10,8 017 = 58,3005 = 17,2 020 = 63,8006 = 21,3 022 = 70,3008 = 26,4 025 = 79,3010 = 34,1 028 = 88,8012 = 37,1 031 = 100,0014 = 46,0

Type of shaft1 = keyed (SAE C)2 = keyed (SAE CC)3 = splined 12/24 (SAE C) (14 teeth)4 = splined 12/24 (SAE CC) (17 teeth)5 = keyed (non SAE)

Modifications

Mounting w/connection variables4 bolts SAE flange J518

P1 & P2 = 1.1/4" - S = 4"

Metric thread UNC thread

P3 1" 3/4" 1" 3/4"

Code M0 M1 00 01

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON® - 7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination (see pages 72 - 73)00 = standard

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

T67DDCS-OrderingCode

P1 P2 P3

OperaTingCharaCTeriSTiCS-TypiCal[24cSt]

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 250 bar p = 7 bar p = 140 bar p = 250 bar

P1

&

P2

B14 44,0 ml/rev 66,0 59,4 54,2 1,5 16,6 29,0

B17 55,0 ml/rev 82,5 75,9 70,7 1,7 20,4 35,8

B20 66,0 ml/rev 99,0 92,4 87,2 1,9 24,3 42,7

B22 70,3 ml/rev 105,5 98,8 93,7 2,0 25,8 45,4

B24 81,1 ml/rev 121,7 115,0 109,9 2,2 29,5 52,1

B28 90,0 ml/rev 135,0 128,4 123,2 2,3 32,7 57,7

B31 99,2 ml/rev 148,8 142,2 137,0 2,5 35,9 63,5

B35 113,4 ml/rev 170,1 163,5 158,3 2,7 40,8 72,3

B38 120,6 ml/rev 180,9 174,3 169,1 2,9 43,4 76,8

B42 137,5 ml/rev 206,3 199,6 194,5 3,2 49,3 87,4

045 145,7 ml/rev 218,6 209,2 202,6 4,1 52,8 89,5

050 158,0 ml/rev 237,0 227,7 223,01) 4,4 57,1 85,01)

p = 0 bar p = 140 bar p = 275 bar p = 7 bar p = 140 bar p = 275 bar

P3

003 10,8 ml/rev 16,2 11,2 * 1,3 5,3 *

005 17,2 ml/rev 25,8 20,8 16,1 1,4 7,5 13,9

006 21,3 ml/rev 31,9 26,9 22,2 1,5 8,9 16,8

008 26,4 ml/rev 39,6 34,6 29,9 1,6 10,7 20,3

010 34,1 ml/rev 51,1 46,1 41,4 1,7 13,4 25,6

012 37,1 ml/rev 55,6 50,6 45,9 1,7 14,4 27,6

014 46,0 ml/rev 69,0 64,0 59,3 1,9 17,6 33,7

017 58,3 ml/rev 87,4 82,4 77,7 2,1 21,9 42,2

020 63,8 ml/rev 95,7 90,7 86,0 2,2 23,8 46,0

022 70,3 ml/rev 105,4 100,4 95,7 2,3 26,1 50,4

025 79,3 ml/rev 118,9 113,9 109,2 2,5 29,2 56,6

028 88,8 ml/rev 133,2 128,2 125,81) 2,8 32,7 48,51)

031 100,0 ml/rev 150,0 145,0 142,61) 2,8 36,5 54,41)

* We do not recommand to use the size 003 in P3 at 275 bar & 1500 RPM as the internal leakage is over 50% of theoretical flow.1) 050 - 028 - 031 = 210

Page 62: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

62 Parker HannifinDenison Vane Pump DivisionVierzon - France

nOiSelevel(TypiCal)-T67DDCS-B31-B31-022inTernalleaKage(TypiCal)

permiSSiBleraDiallOaDpOWerlOSShyDrOmeChaniCal(TypiCal)

60

65

70

75

80

0 40 80 120 160 200 240

Série1

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

400

600

800

1000

1200

1400

1600

1800

2000

600 900 1200 1500 1800 2100 2400

Shaftkeyed

0

2

4

6

8

10

12

14

16

18

20

22

0 40 80 120 160 200 240 280

24 cSt10 cSt

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 1200 NTotal hydromechanical power loss is the sum of each section loss under its respective operating conditions.

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss under its respective operating conditions.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

Triple pump noise level is given with all stages discharging at the pressure value indicated on the curve.

0

1

2

3

4

5

6

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2500 RPM

0

1

2

3

4

0 40 80 120 160 200 240 280

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2500 RPM

P1-P2

P3

P3

P1-P2

P1-P2

P3

P3

P1-P2

P3

P1-P2

T67DDCS-Technicaldata

FaF

==

Shaft keyed N°1

Page 63: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

63 Parker HannifinDenison Vane Pump DivisionVierzon - France

Noiselevel(TypiCal)-T7eDB-062-B35-B04iNTeRNalleaKaGe(TypiCal)

peRmissiBleRaDialloaDpoweRlosshyDRomeChaNiCal(TypiCal)

65

70

75

80

85

0 40 80 120 160 200 240

Série1

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

200

400

600

800

1000

1200

1400

1600

1800

600 1000 1400 1800 2200

Shaftkeye

0

3

6

9

12

15

18

21

24

27

30

33

0 50 100 150 200 250 300

24 cSt10 cSt

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 2000 NTotal hydromechanical power loss is the sum of each section loss under its respective operating conditions.

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss under its respective operating conditions.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

Triple pump noise level is given with all stages discharging at the pressure value indicated on the curve.

012345678

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2200 RPM

0

1

2

3

0 50 100 150 200 250 300

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2200 RPM

P3

P1

P1

P2

P1

P1

P1

T7eDB/T7eDBs-Technicaldata

0123456

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2200 RPM

P2

P2

P2

P3

P3

P3

P2

P3

FaF

==

Shaft keyed N°1

Page 64: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

64 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T7EDB or T7EDBS - 062 - B35 - B10 - 1 R 00 - A 1 - 01 - ..T7EDB series - 250-B4-HWISO 4 bolts 3019-2 mounting flangeT7EDBS series - SAE E 4 boltsJ744 mounting flange

Displacement for “P1”Volumetric displacement (ml/rev)042 = 132,3 054 = 171,0 066 = 213,3045 = 142,4 057 = 183,3 072 = 227,1050 = 158,5 062 = 196,7 085 = 268,7052 = 164,8

Displacement for “P2”Volumetric displacement (ml/rev)B14 = 44,0 B24 = 81,1 B38 = 120,6B17 = 55,0 B28 = 90,0 B42 = 137,5B20 = 66,0 B31 = 99,2 045 = 145,7B22 = 70,3 B35 = 113,4 050 = 158,0

Displacement for “P3”Volumetric displacement (ml/rev)B02 = 5,8 B07 = 22,5 B11 = 35,0B03 = 9,8 B08 = 24,9 B12 = 41,0B04 = 12,8 B09 = 28,0 B14 = 45,0B05 = 15,9 B10 = 31,8 B15 = 50,0B06 = 19,8

Modifications

Mounting w/connection variables4 bolts SAE flange J518

P1 = 1.1/2" - P2 = 1.1/4" - S = 4"Metric thread UNC thread

T7EDB-P3 = 1" M0T7EDB-P3 = 3/4" M1T7EDBS-P3 = 1" M0 00T7EDBS-P3 = 3/4" M1 01

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON® - 7 bar max. (for mineral oil and fire resistant fluids)Design letter

Porting combination (see pages 72 - 73)00 = standard

Direction of rotation (shaft end view)R = Clockwise L = Counter-clockwise

Type of shaft T7EDBS2 = keyed (SAE D & E)3 = splined 8/16 (SAE D & E) (13 teeth)

T7eDB/T7eDBs-orderingCode

P1 P2 P3

opeRaTiNGChaRaCTeRisTiCs-TypiCal[24cst]

1) 085 = 90 bar max. int. 2) 050 = 210 bar max.int. 3) B15 = 280 bar max.int.

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 240 bar p = 7 bar p = 140 bar p = 240 bar

P1

042 132,3 ml/rev 198,5 188,5 181,3 5,2 49,4 82,6045 142,4 ml/rev 213,6 203,6 196,5 5,4 52,9 88,7050 158,5 ml/rev 237,7 227,7 220,6 5,7 58,5 98,3052 164,8 ml/rev 247,2 237,2 230,1 5,8 60,8 102,1054 171,0 ml/rev 256,5 246,5 239,4 5,9 63,0 105,8057 183,3 ml/rev 275,0 265,0 257,9 6,1 67,3 113,2062 196,7 ml/rev 295,0 285,0 277,9 6,4 71,9 121,3066 213,3 ml/rev 319,9 309,0 302,8 6,7 77,7 131,2072 227,1 ml/rev 340,6 330,6 323,5 6,9 82,6 139,5085 268,7 ml/rev 403,0 392,01) - 9,1 65,81) -

p = 0 bar p = 140 bar p = 250 bar p = 7 bar p = 140 bar p = 250 bar

P2

B14 44,0 ml/rev 66,0 59,4 54,2 1,5 16,6 29,0B17 55,0 ml/rev 82,5 75,9 70,7 1,7 20,4 35,8B20 66,0 ml/rev 99,0 92,4 87,2 1,9 24,3 42,7B22 70,3 ml/rev 105,5 98,8 93,7 2,0 25,8 45,4B24 81,1 ml/rev 121,7 115,0 109,9 2,2 29,5 52,1B28 90,0 ml/rev 135,0 128,4 123,2 2,3 32,7 57,7B31 99,2 ml/rev 148,8 142,2 137,0 2,5 35,9 63,5B35 113,4 ml/rev 170,1 163,5 158,3 2,7 40,8 72,3B38 120,6 ml/rev 180,9 174,3 169,1 2,9 43,4 76,8B42 137,5 ml/rev 206,3 199,6 194,5 3,2 49,3 87,4045 145,7 ml/rev 218,6 209,2 202,6 4,1 52,8 89,5050 158,0 ml/rev 237,0 227,7 223,02) 4,4 57,1 85,02)

p = 0 bar p = 140 bar p = 300 bar p = 7 bar p = 140 bar p = 300 bar

P3

B02 5,8 ml/rev 8,7 7,0 5,1 0,5 2,6 5,1B03 9,8 ml/rev 14,7 13,0 11,1 0,6 4,0 8,1B04 12,8 ml/rev 19,2 17,5 15,6 0,6 5,0 10,4B05 15,9 ml/rev 23,9 22,2 20,2 0,7 6,1 12,7B06 19,8 ml/rev 29,7 28,0 26,1 0,7 7,5 15,6B07 22,5 ml/rev 33,7 32,0 30,2 0,8 8,5 17,6B08 24,9 ml/rev 37,4 35,7 33,7 0,8 9,3 19,5B09 28,0 ml/rev 42,0 40,3 38,4 0,9 10,4 21,8B10 31,8 ml/rev 47,7 46,0 44,1 0,9 11,7 26,2B11 35,0 ml/rev 52,5 50,8 48,9 1,0 12,8 27,0B12 41,0 ml/rev 61,5 59,8 57,9 1,1 14,9 31,5B14 45,0 ml/rev 67,5 65,8 63,9 1,2 16,3 34,5B15 50,0 ml/rev 75,0 73,3 71,63) 1,3 18,1 35,73)

Type of shaft T7EDB1 = keyed (ISO 3019/2 - G45N)

Page 65: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

65 Parker HannifinDenison Vane Pump DivisionVierzon - France

T7eDB/eDBs-Dimensions-weight:102kg

273,0106,0

110,

027

3,0

468,

0

22,0

w

100,

712

0,0

1/2

13U

NC

-20

DE

EP

(M12

x 2

0 D

EE

P-M

ETR

IC V

ER

SIO

N)

74,7

100,

042

,913

3,3

148,

412

0,0

Ø S

49,30MAX

44,45Ø 44,40

2,3

x 45

° 1/2-

13 U

NC

x24

DE

EP

SH

AFT

CO

DE

2 (

KE

YE

D S

AE

D &

E )

63,5

KE

Y 11

,11

1

1,06

P1S

P2P3

115,0

139,7

171,

3

101,63,

0x

45°

48,8

8,0

75,0

P135,7

77,8

30,2

B

SP2

P3

208,9

130,2

58,7

69,8

A

1/2

- 13

UN

C x

30

DE

EP

- 4 H

OLE

S(M

12 x

30

DE

EP

- ME

TRIC

VE

RS

ION

)5/

8 - 1

1 U

NC

x 3

0 D

EE

P- 4

HO

LES

(M16

x 3

0 D

EE

P- M

ETR

IC V

ER

SIO

N)

7/16

- 14

UN

C x

24

DE

EP

- 4 H

OLE

S(M

12 x

24

DE

EP

-ME

TRIC

VE

RS

ION)

3/8

- 16

UN

C x

19

DE

EP

- 4 H

OLE

S(M

10 x

19

DE

EP

- ME

TRIC

VE

RS

ION

)

Ø 3

8,1

Ø 1

01,6

Ø 3

1,8

Ø C

MO

UN

TIN

G T

OR

QU

E :

300

Nm

MO

UN

TIN

G T

OR

QU

E :

190

Nm

MO

UN

TIN

G T

OR

QU

E :

54 N

m S

HA

FT C

OD

E 3

SA

E D

& E

INV

OLU

TE S

PLI

NE

DAT

A C

LAS

S 1

-FLA

T R

OO

T S

IDE

FIT

J49

8b -

PIT

CH

8/1

6 1

3 TE

ETH

- 30

° P

RE

SS

UR

E A

NG

LE

8,2

6,4

ex

45°

T7E

DB

S

T7E

DB

w

M12 x 24 DEEP

63,0

10,0

45,000Ø 44,975

48,5MAX

Ø S

KE

Y 14

x 9

SH

AFT

CO

DE

1 (

KE

YE

D G

45N

- IS

O 3

019-

2)

3,0

x 45

°

e x

45°

92,0

KK

/2Ø

d

Ø Z

45°

C.G

.

Shaf

t to

rque

lim

its

[ml/r

ev. x

bar

]Sh

aft

Vi x

p m

ax. P

1 +

P2

+ P

31

1146

002

1183

403

1268

00

Alt

erna

te m

ount

ing

flang

e

Seri

esD

ia S

e x

45°

WK

Dia

ZD

ia d

Max

.M

in.

T7E

DB

250,

000

249,

928

2,0

9,0

-31

522

,0

T7E

DB

S16

5,10

016

5,05

02,

09,

022

4,5

-20

,6

Alt

erna

te c

onne

ct. v

aria

bles

00 &

M0

01 &

M1

A52

,447

,6

B26

,222

,2

C25

,419

,0

Page 66: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

66 Parker HannifinDenison Vane Pump DivisionVierzon - France

T67EDC/EDCS-Dimensions-Weight:102kg

273,0106,0

110,

027

3,0

468,

0

22,0

w

100,

712

0,0

1/2

13U

NC

-20

DE

EP

(M12

x 2

0 D

EE

P-M

ETR

IC V

ER

SIO

N)

74,7

100,

042

,913

3,3

148,

412

0,0

Ø S

49,30MAX

44,45Ø 44,40

2,3

x 45

° 1/2-

13 U

NC

x 24

DE

EP

SH

AFT

CO

DE

2 (

KE

YE

D S

AE

D &

E )

63,5

KE

Y 11

,11

1

1,06

P1S

P2P3

115,0

139,7

171,

3

101,63,

0x

45°

48,8

8,0

75,0

P135,7

77,8

30,2

B

SP2

P3

208,9

130,2

58,7

69,8

A

1/2

- 13

UN

C x

30

DE

EP

- 4 H

OLE

S(M

12 x

30

DE

EP

- ME

TRIC

VE

RS

ION

)5/

8 - 1

1 U

NC

x 3

0 D

EE

P- 4

HO

LES

(M16

x 3

0 D

EE

P- M

ETR

IC V

ER

SIO

N)

7/16

- 14

UN

C x

24

DE

EP

- 4 H

OLE

S(M

12 x

24

DE

EP

-ME

TRIC

VE

RS

ION)

3/8

- 16

UN

C x

19

DE

EP

- 4 H

OLE

S(M

10 x

19

DE

EP

- ME

TRIC

VE

RS

ION

)

Ø 3

8,1

Ø 1

01,6

Ø 3

1,8

Ø C

MO

UN

TIN

G T

OR

QU

E :

300

Nm

MO

UN

TIN

G T

OR

QU

E 1

: 90

Nm

MO

UN

TIN

G T

OR

QU

E :

54 N

m S

HA

FT C

OD

E 3

SA

E D

& E

INV

OLU

TE S

PLI

NE

DAT

A C

LAS

S 1

-FLA

T R

OO

T S

IDE

FIT

J49

8b -

PIT

CH

8/1

6 1

3 TE

ETH

- 30

° P

RE

SS

UR

E A

NG

LE

8,2

6,4

ex

45°

T67

ED

CS

T67

ED

Cw

M12 x 24 DEEP

63,0

10,0

45,000Ø 44,975

48,5MAX

Ø S

KE

Y 14

x 9

SH

AFT

CO

DE

1 (

KE

YE

D G

45N

- IS

O 3

019-

2)

3,0

x 45

°

e x

45°

92,0

KK

/2Ø

d

Ø Z

45°

C.G

.

Shaf

t to

rque

lim

its

[ml/r

ev. x

bar

]Sh

aft

Vi x

p m

ax. P

1 +

P2

+ P

31

1146

002

1183

403

1268

00

Alt

erna

te m

ount

ing

flang

e

Seri

esD

ia S

e x

45°

WK

Dia

ZD

ia d

Max

.M

in.

T67

ED

C25

0,00

024

9,92

82,

09,

0-

315

22,0

T67

ED

CS

165,

100

165,

050

2,0

9,0

224,

5-

20,6

Alt

erna

te c

onne

ct. v

aria

bles

00

01A

52,4

47,6

B26

,222

,2

C25

,419

,0

Page 67: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

67 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T67EDC or T67EDCS - 062 - B35 - 010 - 1 R 00 - A 1 - M1 - ..T67EDC series - 250-B4-HWISO 4 bolts 3019-2 mounting flangeT67EDCS series - SAE E 4 boltsJ744 mounting flange

Displacement for “P1”Volumetric displacement (ml/rev)042 = 132,3 054 = 171,0 066 = 213,3045 = 142,4 057 = 183,3 072 = 227,1050 = 158,5 062 = 196,7 085 = 268,7052 = 164,8

Displacement for “P2”Volumetric displacement (ml/rev)B14 = 44,0 B24 = 81,1 B38 = 120,6B17 = 55,0 B28 = 90,0 B42 = 137,5B20 = 66,0 B31 = 99,2 045 = 145,7B22 = 70,3 B35 = 113,4 050 = 158,0

Displacement for “P3”Volumetric displacement (ml/rev)003 = 10,8 012 = 37,1 022 = 70,3005 = 17,2 014 = 46,0 025 = 79,3006 = 21,3 017 = 58,3 028 = 88,8008 = 26.4 020 = 63,8 031 = 100,0010 = 34,1

Modifications

Mounting w/connection variables4 bolts SAE flange J518

P1 = 1.1/2" - P2 = 1.1/4" - S = 4"Metric thread UNC thread

T67EDC-P3 = 1" M0T67EDC-P3 = 3/4" M1T67EDCS-P3 = 1" M0 00

T67EDCS-P3 = 3/4" M1 01

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)4 = S4 EPDM - 7 bar max. (for fire resistant fluids)5 = S5 VITON® - 7 bar max. (for mineral oil and fire resistant fluids)

Design letter

Porting combination (see pages 72 - 73)00 = standard

Direction of rotation (shaft end view)R = Clockwise L = Counter-clockwise

Type of shaft T67EDCS2 = keyed (SAE D & E)3 = splined 8/16 (SAE D & E) (13 teeth)

T67EDC/T67EDCS-OrderingCode

P1 P2 P3

OpEraTingCharaCTEriSTiCS-TypiCal[24cSt]

* We do not recommand to use the size 003 in P3 at 275 bar & 1500 RPM as the internal leakage is over 50% of theoretical flow. 1) 050 - 028 - 031 = 210 bar max.int. 2) 085 = 90 bar max.int.

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 240 bar p = 7 bar p = 140 bar p = 240 bar

P1

042 132,3 ml/rev 198,5 188,5 181,3 5,2 49,4 82,6045 142,4 ml/rev 213,6 203,6 196,5 5,4 52,9 88,7050 158,5 ml/rev 237,7 227,7 220,6 5,7 58,5 98,3052 164,8 ml/rev 247,2 237,2 230,1 5,8 60,8 102,1054 171,0 ml/rev 256,5 246,5 239,4 5,9 63,0 105,8057 183,3 ml/rev 275,0 265,0 257,9 6,1 67,3 113,2062 196,7 ml/rev 295,0 285,0 277,9 6,4 71,9 121,3066 213,3 ml/rev 319,9 309,0 302,8 6,7 77,7 131,2072 227,1 ml/rev 340,6 330,6 323,5 6,9 82,6 139,5085 268,7 ml/rev 403,0 392,02) - 9,1 65,82) -

p = 0 bar p = 140 bar p = 250 bar p = 7 bar p = 140 bar p = 250 bar

P2

B14 44,0 ml/rev 66,0 59,4 54,2 1,5 16,6 29,0B17 55,0 ml/rev 82,5 75,9 70,7 1,7 20,4 35,8B20 66,0 ml/rev 99,0 92,4 87,2 1,9 24,3 42,7B22 70,3 ml/rev 105,5 98,8 93,7 2,0 25,8 45,4B24 81,1 ml/rev 121,7 115,0 109,9 2,2 29,5 52,1B28 90,0 ml/rev 135,0 128,4 123,2 2,3 32,7 57,7B31 99,2 ml/rev 148,8 142,2 137,0 2,5 35,9 63,5B35 113,4 ml/rev 170,1 163,5 158,3 2,7 40,8 72,3B38 120,6 ml/rev 180,9 174,3 169,1 2,9 43,4 76,8B42 137,5 ml/rev 206,3 199,6 194,5 3,2 49,3 87,4045 145,7 ml/rev 218,6 209,2 202,6 4,1 52,8 89,5050 158,0 ml/rev 237,0 227,7 223,01) 4,4 57,1 85,01)

p = 0 bar p = 140 bar p = 275 bar p = 7 bar p = 140 bar p = 275 bar

P3

003 10,8 ml/rev 16,2 11,2 * 1,3 5,3 *005 17,2 ml/rev 25,8 20,8 16,1 1,4 7,5 13,9006 21,3 ml/rev 31,9 26,9 22,2 1,5 8,9 16,8008 26,4 ml/rev 39,6 34,6 29,9 1,6 10,7 20,3010 34,1 ml/rev 51,1 46,1 41,4 1,7 13,4 25,6012 37,1 ml/rev 55,6 50,6 45,9 1,7 14,4 27,6014 46,0 ml/rev 69,0 64,0 59,3 1,9 17,6 33,7017 58,3 ml/rev 87,4 82,4 77,7 2,1 21,9 42,2020 63,8 ml/rev 95,7 90,7 86,0 2,2 23,8 46,0022 70,3 ml/rev 105,4 100,4 95,7 2,3 26,1 50,4025 79,3 ml/rev 118,9 113,9 109,2 2,5 29,2 56,6028 88,8 ml/rev 133,2 128,2 125,81) 2,8 32,7 48,51)

031 100,0 ml/rev 150,0 145,0 142,61) 2,8 36,5 54,41)

Type of shaft T67EDC1 = keyed (ISO 3019/2 - G45N)

Page 68: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

68 Parker HannifinDenison Vane Pump DivisionVierzon - France

nOiSElEvEl(TypiCal)-T67EDCS-062-B35-022inTErnallEaKagE(TypiCal)

pErmiSSiBlEraDiallOaDpOWErlOSShyDrOmEChaniCal(TypiCal)

65

70

75

80

85

0 40 80 120 160 200 240

Série1

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMυ = 32 cStLw = Lp + 8 db (A)

200

400

600

800

1000

1200

1400

1600

1800

600 1000 1400 1800 2200

Shaftkeye

0

3

6

9

12

15

18

21

24

27

30

33

0 40 80 120 160 200 240 280

24 cSt10 cSt

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 2000 NTotal hydromechanical power loss is the sum of each section loss under its respective operating conditions.

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss under its respective operating conditions.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

Triple pump noise level is given with all stages discharging at the pressure value indicated on the curve.

012345678

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2200 RPM

01234

0 40 80 120 160 200 240 280

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2200 RPM

P3

P1

P1

P2

P1

P1

P1

T67EDC/T67EDCS-Technicaldata

0123456

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2200 RPM

P2

P2

P2

P3P3

P3

P2

P3

FaF

==

Shaft keyed N°1

Page 69: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

69 Parker HannifinDenison Vane Pump DivisionVierzon - France

Noiselevel(TypiCal)-T7eeCs-052-052-025iNTeRNalleaKaGe(TypiCal)

peRmissibleRadialloadpoweRlosshydRomeChaNiCal(TypiCal)

65

70

75

80

85

0 40 80 120 160 200 240

Série1Série

Pe = 0,9 bar absn = 1000 RPMn = 1500 RPMu = 32 cStLw = Lp + 8 db (A)

400

600

800

1000

1200

1400

1600

1800

2000

600 1000 1400 1800 2200

Shaftkeyed

0

5

10

15

20

25

30

35

0 40 80 120 160 200 240 280

24 cSt10 cSt

Pressure p [bar]Pressure p [bar]

Speed n [RPM]Pressure p [bar]

Maximum permissible axial load Fa = 2000 NTotal hydromechanical power loss is the sum of each section loss under its respective operating conditions.

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss under its respective operating conditions.

Inte

rnal

leak

age

qVs [

l/m

in]

Loa

d F

[N

]L

p. N

oise

leve

l [db

(A)]

1m

ISO

441

2

Pow

er lo

ss P

s [k

W]

u

Triple pump noise level is given with all stages discharging at the pressure value indicated on the curve.

0

1

2

3

4

5

6

7

0 30 60 90 120 150 180 210 240

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2200 RPM

0

1

2

3

4

0 40 80 120 160 200 240 280

n = 1000 RPMn = 1500 RPM [24 cSt]n = 2200 RPM

P3

P1-P2

T7eeC/T7eeCs-Technicaldata

P1-P2

P1-P2

P1-P2

P3P3

P3

P1-P2

P3

FaF

==

Shaft keyed N°1

Page 70: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

70 Parker HannifinDenison Vane Pump DivisionVierzon - France

Model No. T7EEC or T7EECS - 062 - 062 - 017 - 2 R 00 - A 1 - M0 - ..T7EEC series - 250-B4-HWISO 4 bolts 3019-2 mounting flange

T7EECS series - SAE E 4 boltsJ744 mounting flange

Displacement for “P1” & "P2"Volumetric displacement (ml/rev)042 = 132,3 057 = 183,3045 = 142,4 062 = 196,7050 = 158,5 066 = 213,3052 = 164,8 072 = 227,1054 = 171,0 085 = 268,7

Displacement for "P3"Volumetric displacement (ml/rev.)003 = 10,8 017 = 58,3005 = 17,2 020 = 63,8006 = 21,3 022 = 70,3008 = 26,4 025 = 79,3010 = 34,1 028 = 88,8012 = 37,1 031 = 100,0014 = 46,0

Modifications

Mounting w/connection variables4 bolts SAE flange J518

P1 = 1.1/2" - P2 = 1.1/2" - P3 = 3/4" & 1" - S = 4"Metric UNC

T7EEC - 3/4" M1T7EECS - 3/4" M1 01T7EEC - 1" M0T7EECS - 1" M0 00

Seal class1 = S1 BUNA N - 0,7 bar max. (for mineral oil)

Design letter

Porting combination (see pages 72 - 73)00 = standard

Direction of rotation (shaft end view)R = ClockwiseL = Counter-clockwise

Type of shaft T7EEC - T7EECS2 = keyed (ISO 3019/2 - G45N))

Type of shaft T7EECS4 = splined 8/16 (SAE D & E) (13 teeth)

T7eeC/T7eeCs-orderingCode

P1 P2 P3

opeRaTiNGChaRaCTeRisTiCs-TypiCal[24cst]

* We do not recommand to use the size 003 in P3 at 275 bar & 1500 RPM as the internal leakage is over 50% of theoretical flow. 1) 028 - 031 = 210 bar max.int. 2) 085 = 90 bar max.int.

Pressure port

SeriesVi Volumetric displacement

Flow qVe [l/min] & n = 1500 RPM Input power P [kW] & n = 1500 RPMp = 0 bar p = 140 bar p = 240 bar p = 7 bar p = 140 bar p = 240 bar

P1

&

P2

042 132,3 ml/rev 198,5 188,5 181,3 5,2 49,4 82,6045 142,4 ml/rev 213,6 203,6 196,5 5,4 52,9 88,7050 158,5 ml/rev 237,7 227,7 220,6 5,7 58,5 98,3052 164,8 ml/rev 247,2 237,2 230,1 5,8 60,8 102,1054 171,0 ml/rev 256,5 246,5 239,4 5,9 63,0 105,8057 183,3 ml/rev 275,0 265,0 257,9 6,1 67,3 113,2062 196,7 ml/rev 295,0 285,0 277,9 6,4 71,9 121,3066 213,3 ml/rev 319,9 309,0 302,8 6,7 77,7 131,2072 227,1 ml/rev 340,6 330,6 323,5 6,9 82,6 139,5085 268,7 ml/rev 403,0 392,02) - 9,1 65,82) -

p = 0 bar p = 140 bar p = 275 bar p = 7 bar p = 140 bar p = 275 bar

P3

003 10,8 ml/rev 16,2 11,2 * 1,3 5,3 *005 17,2 ml/rev 25,8 20,8 16,1 1,4 7,5 13,9006 21,3 ml/rev 31,9 26,9 22,2 1,5 8,9 16,8008 26,4 ml/rev 39,6 34,6 29,9 1,6 10,7 20,3010 34,1 ml/rev 51,1 46,1 41,4 1,7 13,4 25,6012 37,1 ml/rev 55,6 50,6 45,9 1,7 14,4 27,6014 46,0 ml/rev 69,0 64,0 59,3 1,9 17,6 33,7017 58,3 ml/rev 87,4 82,4 77,7 2,1 21,9 42,2020 63,8 ml/rev 95,7 90,7 86,0 2,2 23,8 46,0022 70,3 ml/rev 105,4 100,4 95,7 2,3 26,1 50,4025 79,3 ml/rev 118,9 113,9 109,2 2,5 29,2 56,6028 88,8 ml/rev 133,2 128,2 125,81) 2,8 32,7 48,51)

031 100,0 ml/rev 150,0 145,0 142,61) 2,8 36,5 54,41)

Page 71: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane Pumps T7/T67/T6C

71 Parker HannifinDenison Vane Pump DivisionVierzon - France

T7eeC/eeCs-dimensions-weight:114,8kg42

,9 W

92,0

10,0

273,00

136,50

273,

0013

6,50 Ø

d

Ø S

45,000Ø 44,975

3,0

x 4

e x

45°

MO

UN

TIN

G T

OR

QU

E :

300

N.m

MO

UN

TIN

G T

OR

QU

E :

300

N.m

MO

UN

TIN

G T

OR

QU

E :

68 N

.m

SP

1P

2P

3

119,

651

5,2

K

K

168,

316

0,5

139,7

115,0

115,0

75,0 74,5

118,0

48,5maxi

202,

7

K/2

K/2 Ø

Z

63,0

0K

EY

14 h

9

SH

AFT

CO

DE

2(K

EY

ED

G45

N-IS

O 3

019-

2)

PR

ES

SU

RE

Ø C

36,4

PR

ES

SU

RE

Ø10

1,6

SU

CTI

ON

Ø

38,1

PR

ES

SU

RE

Ø

3/8-

16U

NC

x 1

9 D

EE

P - 4

HO

LES

(M10

x 1

9 D

EE

P - M

ETR

IC V

ER

SIO

N)

5/8-

11 U

NC

x 3

0 D

EE

P - 4

HO

LES

(M16

x 3

0 D

EE

P - M

ETR

IC V

ER

SIO

N) 1/2-

13 U

NC

x 3

0 D

EE

P - 4

HO

LES

(M12

x 3

0 D

EE

P - M

ETR

IC V

ER

SIO

N)

1/2-

13 U

NC

x 2

3.4

DE

EP

- 4 H

OLE

S(M

12 x

23.

4 D

EE

P - M

ETR

IC V

ER

SIO

N)

35,7

69,85

77,8

130,2

35,7

69,85

AB

75,0 3

x 45

°

48,8

W 8,0

Ø S

SH

AFT

CO

DE

4S

AE

D &

E S

PLI

NE

D S

HA

FTC

LAS

S 1

- J49

8b -8

/16

D.P

.13

TE

ETH

-30°

PR

ES

SU

RE

AN

GLE

FLAT

RO

OT

SID

E F

IT

210

C.G

.

Shaf

t to

rque

lim

its

[ml/r

ev. x

bar

]Sh

aft

Vi x

p m

ax. P

1 +

P2

+ P

32

1183

404

1268

00

Alt

erna

te m

ount

ing

flang

e

Seri

esD

ia S

e x

45°

WK

Dia

ZD

ia d

Max

.M

in.

T7E

EC

250,

000

249,

928

2,0

9,0

-31

522

,0

T7E

EC

S16

5,10

016

5,05

02,

09,

022

4,5

-20

,8

Alt

erna

te c

onne

ct. v

aria

bles

00 &

M0

01 &

M1

A52

,447

,6

B26

,222

,2

C25

,419

,0

Page 72: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane PumpsPorting Diagrams T7/T67/T6C

72 Parker HannifinDenison Vane Pump DivisionVierzon - France

00 01 02 03 04 05 06 07

08 09 10 11 12 13 14 15

P1-P2 S-P1-P2P1-P2 P1-P2 P1 P1 P1 P1-S

S

P2

S-P2

S

P2

P1-S P1-S P1 P1 P1 P1 P1 P1

P2 P2

S

SP2

P2

S

P2

S

P2

S

P2

P2S

P2

S

S

S

00 01 02 03 04 05 06 07

08 09 10 11 12 13 14 15

P1-P2 S-P1-P2P1-P2 P1-P2 P1 P1 P1 P1-S

S

P2

S-P2

S

P2

P1-S P1-S P1 P1 P1 P1 P1 P1

P2 P2

S

SP2

P2

S

P2

S

P2

S

P2

P2S

P2

S

S

S

16 17 18 19 20 21 22 23

24 25 26 27 28 29 30 31

P1 P1 P1 P1 P1 P1

P1-S P1-S P1 P1 P1 P1

P1 P1

P1-S P1-S

S S S S

S S S S

P2

P2

P2 P2

P2

P2

P2

P2

P2 P2

P2

P2

P2 P2

P2 P2

S S S S

P1-P2-P3

00 01 02 03 04 05 06 07

08 09 10 11 12 13 14 15

16 17 18 19 20 21 22 23

24 25 26 27 28 29 30 31

32 33 34 35 36 37 38 39

40 41 42 43 44 45 46 47

48 49 50 51 52 53 54 55

56 57 58 59 60 61 62 63

S-P1-P2-P3P1-P2-P3

S

S

P1-P2-P3

S

P1 P1 P1 P1-S

S

P2

P3

S-P2-P3

S

P2

P3

P2

P1-S P1-S P1 P1-P2 P1-P2 P1-P3 P1 P1-P3

S-P1-P2 S-P1-P2S-P1-P2 S-P1-P3 S-P1-P3 S-P1-P3 P1-P2 P1

P1 P1 P1 P1-P3 P1-S P1-S P1-S P1-S

P1-S P1-P2P1-S P1-P2 P1-P2 P1-P2 P1-P2 P1-P2

P1-P3 P1-P3 P1-P3 P1-P3 P1-P3 P1-P3 P1 P1

P1 P1 P1 P1P1 P1 P1 P1

P1 P1 P1 P1P1 P1 P1 P1

P2

P2

P3

P2-P3 P2-P3

S

S-P2

P2

P2

P3

S

S

P2

S

P2

P2

P3

P2-P3

S

P3

P3

P3

P3

S

P2

S

P2

P3

P2

P3

S

P3

S

S

S-P3

P2

P3S

P2

P3 P3

P2

P2

P3

P3

P2

P2

P2P3 P3

P3 P3 S S

S SP3

P3S SP3 P3

S S

P2 P2 S S

P2

P2

P2

P2S S

P3

S

P2 S

P2P3

P2

S

P3

P2

S

P3

S-P2 S-P2 S-P3 S-P3 P3

P3

P3

P2

P2

S

P2

P3

S

P2

S

P3

P2

S

P3P2 P2

P3S

P2

P3 P3 P2S S

S

P3

P2

S

P2

P2

P3

SP3

T7BB/T7BBS

T6CC

T67CB

T7DB/T7DBS

T67DC

T7EB/T7EBS

T67EC

T7DD/T7DDS

T7ED/T7EDS

T7EE/T7EES

T7DBB/T7DBBS

T7DCB/T7DCBS

T7DCC/T7DCCS

T7DBB/T7DBBS

T67DDCS

T7EDB/T7EDBS

T67EDC/T67EDCS

T7EEC/T7EECS

Page 73: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane PumpsPorting Diagrams T7/T67/T6C

73 Parker HannifinDenison Vane Pump DivisionVierzon - France

02 16 17 18

19 07 28 32

01 22 34 38

13 04 46 47

00 36 11 37

42 24 53 60

03 39 35 12

44 26 61 56

20 30 08 31

21 33 29 09

40 48 10 58

45 49 59 23

27 51 05 50

43 62 52 25

41 63 14 57

15 54 55 06

S P2 P3 P2 P3

P1

64 65 66 67 68 69 70 71

72 73 74 75 76 77 78 79

80 81 82 83 84 85 86 87

88 89 90 91 92 93 94 95

96 97 98 99 1A

1P1P1P1P 1P1P1P1P

P1 P1 P1 P1 P1-P2 P1-P2 P1-P2 P1-P2

1B 1C 1D

1E 1F 1G 1H 1J 1K 1L 1M

1N 1P 1R 1S 1T 1U 1V 1W

1X 1Y 1Z 2A 2B 2C 2D 2E

1P1P1P1P 1P1P1P1P

P1 P1 P1 P1 P1-P2 P1-P2 P1-P2 P1-P2

P1-S P1-S P1-S P1-S P1-S P1-S P1-S P1-S

P1-S P1-S P1-S P1-S P1-S-P2 P1-S-P2 P1-S-P2 P1-S-P2

1P1P1P1P 1P1P1P1P

P1 P1 P1 P1 P1-P2 P1-P2 P1-P2 P1-P2

P2

P3

S

P2

P3

S S S S-P2 S-P2 S-P2 S-P2P3 P3

3P3P

P3 P3

P2 P2

S S S S S S S S

P2 P2 P2 P2

3P3P

P3 P3

3P3P

P3 P3

SP2

SP2

SP2

SP2 S S S S

P2 P2 P2 P2

3P3P

P3 P3

3P3P

P3 P3

3P3P

P3 P3

3P3P

P3 P3

SS

S S SP2

SP2

SP2

SP2

3P3P

P3 P3

3P3P

P3 P3

3P3P

P3 P3

3P3P

P3 P3

3P3P

P3 P3

3P3P

P3 P3

3P3P

P3 P3

3P3P

P3 P3

P2 P2 P2 P2

P2 P2 P2 P2

P2 P2 P2 P2

P2P2

SP2

SP2

SS S S S S

P2 P2 P2 P2

SP2

SP2

SP2

SP2 S S S S

T7DBB/T7DBBS

T7DCB/T7DCBS

T7DCC/T7DCCS

T7DBB/T7DBBS

T67DDCS

T7EDB/T7EDBS

T67EDC/T67EDCS

T7EEC/T7EECS

Page 74: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane PumpsNotes T7/T67/T6C

74 Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 75: Parker Vane Pump

Catalogue HY29-0001/UK Industrial Vane PumpsGeneral Information T7/T67/T6C

75 Parker HannifinDenison Vane Pump DivisionVierzon - France

Offer of SalePlease contact your Parker representation for a detailed ’’Offer of Sale’’.

! WarningFAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED

HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.

This document and other information from Parker Hannifin, its subsidiaries, sales offices and authorized distributors provide

product or system options for further investigation by users having technical expertise. Before you select or use any product

or system it is important that you analyse all aspects of your application and review the information concerning the product

or system in the current product catalogue. Due to the variety of operating conditions and applications for these products or

systems, the user, through his own analysis and testing, is solely responsible for making the final selection of the products and

systems and assuring that all performance and safety requirements of the application are met.

The products are subject to change by Parker Hannifin at any time without notice.

Page 76: Parker Vane Pump

Parker Hannifin is the world’s premier supplier of motion and control systems and solutions, with sales and manufacturing facilities throughout the world. For product information and details of your nearest Parker sales office, visit us at www.parker.com or call free on 00800 2727 5374.

Hydraulics GroupSales Offices

Austria Wiener NeustadtTel: +43 (0)2622 23501Fax: +43 (0)2622 66212

Austria Wiener Neustadt (Resp for East Europe)Tel: +43 (0)2622 23501-970Fax: +43 (0)2622 23501-977

Belgium NivellesTel: +32 (0)67 280 900 Fax: +32 (0)67 280 999

Czech Republic KlecanyTel: +420 284 083 111 Fax: +420 284 083 112

Denmark BallerupTel: +45 4356 0400 Fax: +45 4373 3107

Finland VantaaTel: +358 20 753 2500 Fax: +358 20 753 2200

France Contamine-sur-ArveTel: +33 (0)450 25 80 25 Fax: +33 (0)450 25 24 25

GermanyKaarstTel: +49 (0)2131 4016 0 Fax: +49 (0)2131 4016 9199

Ireland DublinTel: +353 (0)1 466 6370 Fax: +353 (0)1 466 6376

Italy Corsico (MI)Tel: +39 02 45 19 21 Fax: +39 02 4 47 93 40

The Netherlands OldenzaalTel: +31 (0)541 585000 Fax: +31 (0)541 585459

Norway SkiTel: +47 64 91 10 00 Fax: +47 64 91 10 90

Poland WarsawTel: +48 (0)22 573 24 00 Fax: +48 (0)22 573 24 03

Portugal Leca da PalmeiraTel: +351 22 9997 360 Fax: +351 22 9961 527

Slovakia Ref. Czech Republic

Spain MadridTel: +34 91 675 73 00 Fax: +34 91 675 77 11

Sweden SpångaTel: +46 (0)8 597 950 00 Fax: +46 (0)8 597 951 10

United Kingdom Warwick Tel: +44 (0)1926 317 878 Fax: +44 (0)1926 317 855

InternationalEurope

Catalogue HY29-0001/UK5M 03/2007 IRO

© Copyright 2007 Parker Hannifin CorporationAll rights reserved

Australia Castle HillTel: +61 (0)2-9634 7777 Fax: +61 (0)2-9842 5111

Canada Milton, OntarioTel: +1 905-693-3000 Fax: +1 905-876-0788

China ShanghaiTel: +86 21 5031 2525 Fax: +86 21 5834 3714

Asia Pacific GroupHong KongTel: +852 2428 8008 Fax: +852 2425 6896

IndiaMumbaiTel: +91 22 5613 7081/82-85 Fax: +91 22 2768 6841/6618

JapanTokyoTel: +(81) 3 6408 3900 Fax: +(81) 3 5449 7201

Latin America GroupBrazilTel: +55 51 3470 9144 Fax: +55 51 3470 9281

South Africa Kempton ParkTel: +27 (0)11-961 0700 Fax: +27 (0)11-392 7213

USACleveland (industrial)Tel: +1 216-896-3000 Fax: +1 216-896-4031Lincolnshire (mobile)Tel: +1 847-821-1500 Fax: +1 847-821-7600