Paradise Datacom Mini-Redundant SSPA 209495 RevA
description
Transcript of Paradise Datacom Mini-Redundant SSPA 209495 RevA
209495 REV A ECO 16884 1 OF 8
Redundant Systems Mini Compact Outdoor SSPA
Teledyne Paradise Datacom LLC Teledyne Paradise Datacom Ltd. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End State College, PA 16803 USA Witham, Essex CM8 3HA United Kingdom Tel: (814) 238-3450 Tel: +44(0) 1376 515636 Fax: (814) 238-3829 Fax: +44(0) 1376 533764
www.paradisedata.com
FEATURES • System Output Power to:
200 W C-Band; 200 W X-Band; 80 W Ku-Band
• Universal Input, Power Factor Corrected Power Supply
• Output Power Monitoring • Separate 1RU Redundant
Controller or Controller-less configurations
OPTIONS • System Output Power
Monitor • L-Band Input operation • Input switching or Input
splitting • Cold Standby Amplifier
Operation
DESCRIPTION Teledyne Paradise Datacom’s Outdoor series of redundant Mini Compact Outdoor amplifier systems provide the highest degree of earth station redundancy and reliability. Based on Teledyne Paradise Datacom’s family of rugged and robust SSPAs, these systems provide the highest MTBFs possible. These systems can be configured in either 1:1 or 1:2 redundant configurations using the Teledyne Paradise Datacom family of redundant controllers. The RCP2-1100 and RCP2-1200 Redundant Controllers provide an extremely user-friendly interface for complete monitor and control of the high power amplifiers in either 1:1 or 1:2 configurations. The RCP front panel mimic display shows the on-line amplifiers and the current switch positions. Dedicated fault lights provide easy indication of system status. All RCP monitor and control is available locally at the front panel LCD display, and also remotely by the RS-232, RS-485 or Ethernet interface ports.
C-Band 1:1 Redundant Mini Compact Outdoor Plate Assembly
209495 REV A ECO 16884 2 OF 8
Redundant Systems Mini Compact Outdoor SSPA
Single Thread Amplifier Model
1:1 Redundant Output Power PSAT dBm (W) P1dB dBm (W)
HPAXX3050AC 46.8 (48) 46.3 (43)
HPAXX3075AC 48.6 (72) 48.1 (65)
HPAXX3100AC 49.8 (95) 49.3 (85)
1:1 Redundant Output Power
PSAT dBm (W) PLINEAR dBm (W)
HPAXX3200AC 52.8 (190) 49.8 (95)
Single Thread Amplifier Model
Typical X-Band System Output Power Typical C-Band System Output Power
Single Thread Amplifier Model
1:1 Redundant Output Power PSAT dBm (W) P1dB dBm (W)
HPACC3075AC 48.6 (72) 48.3 (68)
HPACC3100AC 49.8 (95) 49.3 (85) 1:1 Redundant Output Power
PSAT dBm (W) PLINEAR dBm (W)
HPACC3200AC 52.8 (190) 49.8 (95)
Single Thread Amplifier Model
Mini Compact Outdoor Output Power Levels
C-Band: 75 W - 200 W X-Band: 50 W - 200 W Ku-Band: 50 W - 80 W
Single Thread Amplifier Model
1:1 Redundant Output Power PSAT dBm (W) P1dB dBm (W)
HPAKU3050AC 46.8 (48) 45.8 (38)
Single Thread Amplifier Model PSAT dBm (W) PLINEAR dBm (W)
HPAKU3080AC 48.8 (76) 45.8 (38)
1:1 Redundant Output Power
Typical Ku-Band System Output Power
209495 REV A ECO 16884 3 OF 8
Redundant Systems Mini Compact Outdoor SSPA
General Specifications PARAMETER NOTES LIMITS UNITS Gain Gain Flatness Gain Slope Gain Variation vs. Temperature Gain Adjustment
minimum full band (C-/X-/Ku-Bands)
full band (Extended C-Band, Extended Ku-Band) per 40 MHz
-40°C to +60°C 0.1 dB resolution
67 ±1.0 ±1.5 +0.3 ±1.5 20
dB dB dB
dB/40 MHz dB dB
Intermodulation Distortion Two-tone 3dB back off relative to P1dB @ rated PLINEAR
1 -25 -25
dBc dBc
AM/PM Conversion (@ rated P1dB) (@P1dB-1dB) (@P1dB-2dB)
(@ rated PLINEAR)1
3.5 1.5 1.0 2.0
°/dB °/dB °/dB °/dB
Spurious (SSPA only) Harmonics (SSPA only)
(@ rated P1dB), (@ rated PLINEAR)1 (@ rated P1dB-3dB), (@ rated PLINEAR)1
-60 -50
dBc dBc
Input/Output VSWR 1.50:1 Noise Figure at maximum gain 10 dB Group Delay (per 40 MHz segment)
Linear Parabolic
Ripple
0.01 0.003
1.0
ns/MHz ns/MHz2
ns p-p Transmit Band Noise Output Power Density
TX Band RX Band
-75 -150
dBW/4 KHz dBW/4 KHz
Residual AM Noise 0 - 10 KHz 10 KHz - 500 KHz 500 KHz - 1 MHz
-45 -20 (1.25 + log F)
-80
dBc dBc dBc
Phase Noise Offset frequency from carrier 10 Hz
100 Hz 1 KHz
10 KHz 100 KHz 1 MHz
-90
-100 -110 -120 -125 -130
dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz
RF Power Detector Psat to (Psat - 20 dBm) 20 ± 1.0 dBm
Environmental Operating Temperature Ambient -40 to +60 °C Relative Humidity condensing 100 % Cooling System Integrated, Forced Air 265 CFM
1 200W C-Band, 200W X-Band and 80W Ku-Bands only.
Mechanical Size, Mini Compact Outdoor width X length X height 9.0 X 12.0 X 6.50
229 X 305 X 165 inches
mm Weight, Mini Compact Outdoor Base unit 24.5 (11.2) ± 3% lbs.(kg) Finish Paint White; powder coat
Specifications are subject to change.
Connectors RF Input RF Output - Ku-Band RF Output - C-Band RF Output - X-Band RF Output Sample
Line Power Monitor and Control
Link Port Redundancy Switch
Auxiliary +15VDC LNB Power (500 mA)
Type N WR75 Waveguide
WR137 Waveguide WR112 Waveguide
Type N 3-pin MS type
32-pin MS type 6-pin MS type 6-pin MS type 6-pin MS type
Female Grooved Flange Grooved Flange Grooved Flange
Female Plug
Socket Socket Socket Socket
209495 REV A ECO 16884 4 OF 8
Redundant Systems Mini Compact Outdoor SSPA
L-Band Operation
Paradise Datacom offers C-, X-, and Ku-Band amplifiers with an integrated L-Band Block Up Converter.
• BUC includes Smart Reference Technology which enables the BUC to detect and switch to an extenally supplied reference.
• Optional internal high stability reference. • Can lock to an externally supplied reference of 10 or 50 MHz without
modification. • Can accept a wide range of external reference power (-10dBm to +5 dBm) • Can accept FSK monitor and control signal via the IFL.
Electrical Specifications for Mini Compact Outdoor SSPA with BUC PARAMETER NOTES LIMITS UNITS
Gain Gain Flatness Gain Slope Gain Adjusted Range Gain Stability
Nominal setting full band (C-,X-,Ku-bands) full band (Extended C-/Ku)
per 40 MHz (C-,X-,Ku-bands)
Typical Adj. Range -40 to +60 °C
75 ± 2.0 ± 2.5 ± 0.5
20 55 - 75 ± 1.5
dB dB dB
dB/40 MHz dB dB dB
Phase Noise Offset frequency from carrier 10 Hz
100 Hz 1 KHz
10 KHz 100 KHz 1 MHz
Absolute max. -30 -60 -70 -80 -90 -90
C-band (typ.) -60 -80 -80 -85
-120 -125
X-band (typ.) -60 -75 -75
-100 -110 -122
Ku-band (typ.) -50 -65 -72 -90
-110 -120
dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz
Spurious
In-Band Signal Related (C-/X-/Ku-Band) (Extended C-Band)
Close to Carrier Spurious (< 20 MHz) Local Oscillator
Non-Signal Related
-50 -40 -50 -30 -40
dBc dBc dBc dBm dBm
Noise Figure At 75 dB gain setting 20 dB
Input VSWR L-Band 1.5 : 1
Internal Reference Option Reference accuracy @ 25 °C Reference Stability over Temperature (-20 to +85 °C)
± 3 • 10-7 ± 1.5 • 10-8
Available Frequency Plans Band Frequency Band IF Input LO Frequency RF Output Gain Change
C Standard C-Band 950 - 1525 MHz 4.900 GHz 5.850 - 6.425 GHz 0-4 dB
C Extended C-Band 950 - 1825 MHz 4.900 GHz 5.850 - 6.725 GHz 0-4 dB
X Standard X-Band 950 - 1450 MHz 6.950 GHz 7.900 - 8.400 GHz 0-2 dB
Ku Standard Ku-Band 950 - 1450 MHz 13.050 GHz 14.00 - 14.50 GHz 0-2 dB
Ku Extended Ku-Band 950 - 1700 MHz 12.800 GHz 13.75 - 14.50 GHz 0-2 dB
Ku Sub Ku-Band 1 1200 - 1450 MHz 11.800 GHz 13.00 - 13.25 GHz 0-2 dB
Ku Sub Ku-Band 2 950 - 1450 MHz 11.800 GHz 12.75 - 13.25 GHz 0-2 dB
209495 REV A ECO 16884 5 OF 8
Redundant Systems Mini Compact Outdoor SSPA
The RCP2-1X00 is the heart of the Redundant System. It provides an extremely user friendly interface for complete monitor and control of the high power amplifiers. The front panel mimic display shows the on-line amplifiers and the current switch positions. Dedicated fault lights are provided for easy indication of system status. All RCP2-1X00 monitor and control is available locally, at the front panel LCD display, as well as remotely by the RS-232 or RS-485 interface ports. Audible alarms and a full compliment of parallel I/O signal are available at the rear panel of the RCP2-1X00.
1:1 Redundant HPA System, Input Switching
1:2 Redundant HPA System, Input Switching
RF OUT-POL 2
RF OUT-POL 1
Amp 1
Amp 2
Amp 3
RF IN-POL 1
RF IN-POL 2
Teledyne Paradise Datacom’s Mini Compact Outdoor Redundant Systems are designed with built-in redundancy for 1:1 systems, so all system-level monitor and control is internal and no separate controller is required, although an optional RCP2-1100 1:1 Redundant Controller is available. Either Ethernet or RS-485 communications are selectable for user monitor and control. All 1:2 redundant systems require a separate RCP2-1200 Redundant Controller.
RCP2-1200 1:2 Redundant Controller
RCP2-1100 1:1 Redundant Controller
209495 REV A ECO 16884 6 OF 8
Redundant Systems Mini Compact Outdoor SSPA
9.00 [228.6]
9.00 [228.6]
.00[0]
1.00[25.4] (2x)
11.75[298.45] (4x)
22.50[571.5] (2x)
23.50[596.9]
.00
[0]
1.00
[25.
4] (3
x)
5.57
[141
.5]
8.40
[213
.36]
(2x)
11.7
5[2
98.4
5]
20.4
0[5
18.1
6] (2
x)
22.5
0[5
71.5
] (3x
)
23.5
0[5
96.9
]
Ø.39 [Ø9.8]
.00[0]
.25[6.35]
11.20[284.4]
12.32[312.92]
Outline Drawing, Typical Ku-Band Mini Compact Outdoor SSPA 1:1 Redundant System
209495 REV A ECO 16884 7 OF 8
Redundant Systems Mini Compact Outdoor SSPA
Outline Drawing, Typical C-Band Mini Compact Outdoor SSPA 1:1 Redundant System
9.00 [228.60]
9.00 [228.60]
.00
[.00]
1.00
[25.
40] (
3x)
5.00
[127
.00]
8.40
[213
.36]
(2x)
11.7
5[2
98.4
5]
20.4
0[5
18.1
6] (2
x)
22.5
0[5
71.5
0] (3
x)
23.5
0[5
96.9
0]
.00[.00]
1.00[25.40] (2x)
11.75[298.45]
22.50[571.50] (2x)
23.50[596.90]
Ø.39 [Ø9.80]
.00[.00]
.25[6.35]
11.20[284.40]
12.57[319.39]
209495 REV A ECO 16884 8 OF 8
Redundant Systems Mini Compact Outdoor SSPA
Part Number Configuration, Mini Compact Outdoor Systems
HPA
Package C = Mini Compact Outdoor
System Configuration A1 = 1:1 w/ Input Switching, Internal control B = 1:1 w/ Input Splitter, Internal control C1 = 1:2 w/ Input Switching & RCP2-12002 D1 = 1:2 w/ Input Switching, Internal control F = 1:1 w/ Input Splitter & RCP2-11002 H1 = 1:1 w/ Input Switching & RCP2-11002 S = System (Custom) 1 Not available with BUC option P. 2 Standard Cable Length of 100 ft. (30m) with RCP unit.
3 C
Block Up Converter A = None (RF Input) M = Internal Reference BUC P = External Reference BUC
Frequency Sub Band C-Band
A1 - 5.85 - 6.425 GHz B1 - 5.85 - 6.725 GHz
X-Band
A1 - 7.90 to 8.40 GHz
Ku-Band A1 - 14.00 - 14.50 GHz B1 - 13.75 - 14.50 GHz E1,2 - 13.00 - 13.25 GHz F1,2 - 12.75 - 13.25 GHz 1 Available with optional BUC. 2 Not available in 80W Ku-Band units.
Configuration Modifier XXX = Standard XMX = MS-Connector Covers XTX1 = Transmit Band Filter XUX1 = MS-Connector Covers & Transmit Band Filter 1 X-Band only.
Specifications in this document are subject to change without notice.
Band CC - C-Band XX - X-Band KU - Ku-Band
Power Level (in Watts)
C-Band 075, 100 or 200
X-Band 050, 075, 100
or 200 Ku-Band
050 or 080