PANTOGRAPH Type SPL - Sécheron

4
ELECTRICAL SAFETY SOLUTIONS / RAIL VEHICLES PANTOGRAPH Type SPL

Transcript of PANTOGRAPH Type SPL - Sécheron

Page 1: PANTOGRAPH Type SPL - Sécheron

ELECTRICAL SAFETY SOLUTIONS /

RAIL VEHICLES

PANTOGRAPH Type SPL

Page 2: PANTOGRAPH Type SPL - Sécheron

PANTOGRAPH FOR LIGHT RAIL VEHICLE, TYPE SPL2

GENERAL INFORMATIONSPL pantograph is the ideal solution for manufacturers and operators of tramways and light rail vehicles, looking for an efficient and reliable current collecting device. With its wide working range (500 – 3300 mm above roof) and record flatness (300mm above roof), Sécheron SPL pantograph achieves high performances with constrained weight and great stiffness of design. Its unique panhead suspension system offers SPL pantograph an excellent dynamic behaviour, with great

benefits to the contact reliability between the pantograph and overhead lines, as well as to the carbon strips life time. SPL are thoroughly tested and surpass standard requirements, making them fully compliant with EN 50126-2/IEC 60494-2 and EN/IEC 61373.In commercial operation on different tramway networks throughout Europe, SPL pantograph has demonstrated its robustness and reliability in different operational and climatic conditions.

DATA FOR PRODUCT SELECTIONSymbol Unit SPL26 / SPL30

Mechanical characteristicsMaximal running speed VMAX [km/h] 80 (100 in option)Static contact force [N] 60 - 110Maximum weight (without insulators) [kg] 158 ±5Main high voltage circuitRated voltage [VDC] 900 or 1’800Rated insulation voltage (HV parts agains LV parts) [VDC] 2’300Rated current [A] 1’000Peak current [A] 1’500Maximum standstill current [A] 200Overvoltage category OV4

LOW VOLTAGE CIRCUITSNominal voltage [VDC] 24, 36/37.5Range of voltage [0.7 - 1.25] Un

Nominal operating power [W]/[S] 260/10Mechanical raising time to [s] ≤ 10Mechanical lowering time tc [s] ≤ 10Auxiliary contacts 2 change-over (CO)LV connector Harting HAN 16E

OPERATING CONDITIONSInstallation OutdoorWorking ambient temperature Tamb [°C] -25°C to +40°CShocks and mechanical vibrations (according to IEC61373) Category 1 Class AHumidity Class 5K2Pollution degree PD4

contact strips panhead

transfer cam

DESIGN

A simple design, made of 4 main elements, guarantees the pantograph reliable operation for operators:

1. The base frame made of a steel welded lightweight profile, enables fixing the pantograph on the vehicle through four insulators. The frame houses all of the other parts (lower and upper arms as-sembly, damper linear actuator, high and low-voltage electrical interfaces).

2. The lower and upper arms are made of welded thin steel tubes, housing insu-lated maintenance free bearings. Two unstrained stainless steel rods insure the rigidity. Flexible braids allow safe electrical connections.

3. The panhead, installed on a leaf spring suspension system, is designed to allow free movements in all necessary direc-tions to always guarantee the electrical continuity between the contact strips and the overhead line.

4. The drive unit combines the linear actu-ator with the main spring to operate the pantograph.

upper arm upper rod

lower rod

base frame

panhead horns

lower arm

fixing insulator

damper

main spring

linear actuator

Page 3: PANTOGRAPH Type SPL - Sécheron

3PANTOGRAPH FOR LIGHT RAIL VEHICLE, TYPE SPL

PRODUCT INTEGRATIONAll dimensions and characteristics in this brochure are valid for standard tramway and light rail vehicles pantographs.Shall your vehicle-pantograph interfaces be different, please contact Sécheron.

Symbol Unit SPL26 / SPL30Mechanical characteristicsMaximal running speed VMAX [km/h] 80 (100 in option)Static contact force [N] 60 - 110Maximum weight (without insulators) [kg] 158 ±5Main high voltage circuitRated voltage [VDC] 900 or 1’800Rated insulation voltage (HV parts agains LV parts) [VDC] 2’300Rated current [A] 1’000Peak current [A] 1’500Maximum standstill current [A] 200Overvoltage category OV4

LOW VOLTAGE CIRCUITSNominal voltage [VDC] 24, 36/37.5Range of voltage [0.7 - 1.25] Un

Nominal operating power [W]/[S] 260/10Mechanical raising time to [s] ≤ 10Mechanical lowering time tc [s] ≤ 10Auxiliary contacts 2 change-over (CO)LV connector Harting HAN 16E

OPERATING CONDITIONSInstallation OutdoorWorking ambient temperature Tamb [°C] -25°C to +40°CShocks and mechanical vibrations (according to IEC61373) Category 1 Class AHumidity Class 5K2Pollution degree PD4

To limit damages caused by abnormal shocks applied to the pantograph’s panhead during operation, an Automatic Dropping Device can be mounted on the pantograph for a fast-drop action.

AUTOMATIC DROPPING DEVICE (ADD)

OPTIONSMANUAL OPERATIONS DEVICE (MOD)

Connection to linear actuator

Shock detection trigger on panhead

Would the auxiliary power supply be unavailable, the pantograph can be manually operated through a flexible shaft linked to the linear actuator and accessible from inside the vehicle.

SPL30 SPL26

Wor

king

rang

e

Min. working position

Max. working position

Max. extension

LoweredPosition

Fixinginsulator

0

300

500

3300

3400

0

300

500

2900

2950

(mm)

SPL30 SPL26

0

1107

1957

2298

0

798

1648

1967

2453 2122

1700

(mm)

B

A

BB

1000

300

220

300

min 50

B

25

40

HV connections

A

402050

1203 x Ø11

3 x Ø11

HV connections

HV connections

Page 4: PANTOGRAPH Type SPL - Sécheron

Copyright© 2019 Sécheron SA

This document is not contractual and contains information corresponding to the level of technology at the date of printing. Sécheron reserves the right to modify and/or improve the product, whose characteristics are described in these documents, as required by new technology at any time. It is the purchaser’s responsibility to inform himself, no matter what the circumstances, of the product’s maintenance conditions and requirements. Sécheron reserves all rights, especially those arising from our “General Delivery Conditions”.

SG

4803

37B

EN

_C02

-04.

19

Sécheron SA Rue du Pré-Bouvier 251242 Satigny - GenevaCH-Switzerland

Tel: +41 22 739 41 11Fax: +41 22 739 48 [email protected]

Pla

ce a

nd d

ate:

N

ame:

S

igna

ture

:

DESIGNATION CODE FOR ORDERING• Be sure to establish the designation code from the latest version of our brochure by downloading it from the website:

www.secheron.com.• For technical reasons some variants and options indicated in the designation code might not be combined, therefore

validate your configuration with Sécheron before ordering.• For other configurations not described in the brochure, please contact Sécheron.

DESIGNATION CODE

Line Description Designation Standard Options Customer’s choice

10 Product type SPL SPL SPL SPL

11 Max. working extension above roof SPL30: 3’300 mm •SPL26: 2’900 mm •

12 Rated operational voltage 900 VDC •1’800 VDC •

13 Maximum running current 1’000 A •1’500 A •

14 Maximum standstill current 100 A •150 A •200 A •

Please specify optional maximum standstill current below

15 High voltage interface 4 × M12 •4 × M10 •3 × M16 •

16 HV interface Location Below Panhead/Both sides • X

17 Control voltage (electric drive) 24 VDC •36 / 37.5 VDC •

18 Color Dark grey (RAL7011) •Please specify optional RAL color code below •

19 Manual operation device (MOD) No •Yes •

20 - Length of MOD flexible shaft 1.5 m •

Optional length 2.0 & 2.5 m •21 - MOD switch output LV connector •

Free end cables (20cm × 3) •22 Automatic dropping device (ADD) No •

Yes •

A: total width: _______________________________________ mm

B: distance between strips center lines: ________________ mm

C: strip width: ______________________________________ mm

D: strip length: ______________________________________ mm

Horn material Aluminium Insulating material

Strip material Carbon Metal impregnated carbon Copper

B

C

D

A

PANHEAD CHARACTERISTICS

Maximum standstill current: ________________ A

Length of the MOD flexible shaft: ________________ mm ± __________ mm Color option: RAL __ __ __ __

CUSTOMER DATA