Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal...

12
Panels and thermo insulation systems Price List october 2014 Thicknesses up to 200mm

Transcript of Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal...

Page 1: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for

Pane

ls a

nd

the

rmo

insu

latio

n s

yste

ms

Pri

ce

Lis

to

cto

be

r 2

014

Thicknesses

up to 200mm

Page 2: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for

Price list october 2014

● = standard production normally in-stock● = produced on request and time of delivery to be determined= produced on request and minimum quantity required

Sizes a thicknesses from those indicated are produced on request and minimum quantity required.B = Panels with rabbets along the long sidesR = Thermal Resistence expressed in m2K/W, derived from the thermal conductivity value (λD)U = Thermal Trasmittance expressed in W/m2K, derived from the thermal conductivity value (λD)N.B. All Stiferite’s panels thicker than 20mm, may be produced with rabbets along the sides, upon request.

Packaging: Stiferite’s panel are packaged in closed packs of thermoplastic.Delivery: Ex-works from our warehouse in Padova, ItalyTransport: Delivery by trucks of 60-100 cubic meters is available upon request. Lesser quantities (minimum 15 cubic meters) may be delivered by groupage. Label: All packs carry a label with the following information: Name and abbreviation of the product, thickness, size, number of pieces, quantity in square meters, date of production and technical data as required by the CE marking procedure.Stocking: Panels must be off the ground and inside a dry area if stored for an extended period.Modifications: At any moment and without prior notice, Stiferite Srl reserves the right to make changes to the characteristics and the prices of the products reported in this price list.Rabbeting: The rabbets along the sides will cause a reduction of panel width of approximately 12 mm.

For further information on the type of product most suitable for a specific application, refer to the techni-cal documentation available also on-line at http://www.stiferite.com. The following table is only for the more common applications.

Legend

Indications and instructions

Main applications

Clas

s B

- B

H

Clas

s S

- SH

Clas

s SK

Fire

B

GT

GTE

AI4

GT3

- G

T4 -

GT5

RP1

- R

P3

Isov

entil

ato

GT

Win

d

ROOFS

Flat under waterproofing bituminous mantles in view, fixed with hot torch • • •Flat under waterproofing synthetic mantles in view, glued or mechanically fixed • • •Flat under ballasted or paved roofs • • • • •Under flat driveway roof • •Pitched under clay tiles or sheet metal • • • • • •Pitched under a full or micro-ventilated system • • • • •WALLS

In cavities • • • •Internal bump resistive walls • • • • •External Thermal Insulation or ETIC Systems •External ventilated facade systems • • • • •Thermal Bridge Free •FLOORS

Civil or industrial floors • • •Heated floors • • •Civil or industrial floors • • • •

Page 3: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for

Price list october 2014

Polyiso foamFacers:Duotwin®

Applications:Roof insulationInsulation for walls and floors

Thickness mm

Rm2K/W

UW/m2K

Dimension mm

Unit/Package Price€/m2

n. pieces m2

20 ● 0,87 1,15 600 x 1200 30 21,60 7,17

30 ● 1,30 0,77 600 x 1200 20 14,40 9,17

40 ● 1,74 0,58 600 x 1200 16 11,52 11,22

40 ●B 1,74 0,58 1200 x 2800 6 20,16 11,22

50 ● 2,17 0,46 600 x 1200 14 10,08 13,17

50 ●B 2,17 0,46 1200 x 2800 5 16,80 13,17

60 ● 2,61 0,38 600 x 1200 12 8,64 15,15

60 ●B 2,61 0,38 1200 x 2800 4 13,44 15,15

70 ● 3,04 0,33 600 x 1200 10 7,20 17,92

80 ● 3,48 0,29 600 x 1200 8 5,76 19,72

90 ● 3,91 0,26 600 x 1200 8 5,76 21,99

100 ● 4,35 0,23 600 x 1200 6 4,32 24,16

110 ● 4,78 0,21 600 x 1200 6 4,32 27,34

120 ● 5,22 0,19 600 x 1200 6 4,32 29,32

FACER DUOTWIN®

Polyiso foamFacers:Multi-layer aluminium reinforced with glass netting on both sides, for improved adhesiveness to the braces used in installation of heated floor systems.Applications:Roof insulationRoof insulationInsulation for walls and floorsInsulation for “ventilated facades” Resistence to vapour factor: u>8990

Thickness mm

Rm2K/W

UW/m2K

Dimension mm

Unit/Package Price€/m2

n. pieces m2

20 ● 0,87 1,15 600 x 1200 30 21,60 7,31

30 ● 1,30 0,77 600 x 1200 20 14,40 9,36

40 ● 1,74 0,58 600 x 1200 16 11,52 11,46

50 ● 2,17 0,46 600 x 1200 14 10,08 13,46

60 ● 2,61 0,38 600 x 1200 12 8,64 15,48

70 ● 3,04 0,33 600 x 1200 10 7,20 18,45

80 ● 3,48 0,29 600 x 1200 8 5,76 20,16

90 ● 3,91 0,26 600 x 1200 8 5,76 22,47

100 ● 4,35 0,23 600 x 1200 6 4,32 24,82

110 ● 4,78 0,21 600 x 1200 6 4,32 27,82

120 ● 5,22 0,19 600 x 1200 6 4,32 29,53

MULTI-LAYER ALUMINIUM FACER

GT

GTE

PANELS

● = standard production normally in-stock● = produced on request and time of delivery to be determined

NEW

λD = 0,023 W/mK

λD = 0,023 W/mK

Page 4: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for

Price list october 2014

High Performance under heavy loads

Polyiso foamFacers: saturated glass fiberApplications:Flat roofs under waterproofing synthetic or bituminous mantles in view, glued or mechanically fixed. Insulation for floors requiring highresistance to compression.

Polyiso foamFacers: saturated glass fiberApplications: External insulation for “ETIC Systems” and “ventila-ted facades”Insulation used to eliminate “Thermal Bridges”Panel is also available upon request and only in thicknesses of 80mm-200mm for use in Mechanical ETICSystems.

SPECIAL FOR ETICS SYSTEMS

Polyiso foamFacers:saturated glass fiberApplications:Flat roofs under waterproofing synthetic or bituminous mantles in view, glued or mechanically fixed

PANELS

Class SK

Class S

Class SH

Thickness mm

Rm2K/W

UW/m2K

Dimension mm

Unit/Package Price€/m2n. pieces m2

20 ● 0,71 1,40 600 x 1200 30 21,60 7,4130 ● 1,07 0,93 600 x 1200 20 14,40 9,3340 ● 1,43 0,70 600 x 1200 16 11,52 11,5550 ● 1,79 0,56 600 x 1200 14 10,08 13,5860 ● 2,14 0,47 600 x 1200 12 8,64 15,6870 ● 2,50 0,40 600 x 1200 10 7,20 18,6980 ● 3,08 0,33 600 x 1200 8 5,76 20,5590 ● 3,46 0,29 600 x 1200 8 5,76 22,83

100 ● 3,85 0,26 600 x 1200 6 4,32 25,08110 ● 4,23 0,24 600 x 1200 6 4,32 28,09120 ● 4,80 0,21 600 x 1200 6 4,32 29,87130 ● 5,20 0,19 600 x 1200 6 4,32 32,61140 ● 5,60 0,18 600 x 1200 6 4,32 34,36160 ● 6,40 0,16 600 x 1200 4 2,88 38,70180 ● 7,20 0,14 600 x 1200 4 2,88 43,45200 ● 8,00 0,12 600 x 1200 4 2,88 48,20

da 20 a 70 mm λD = 0,028 W/mK da 80 a 110 mm λD = 0,026 W/mKda 120 a 200 mm λD = 0,025 W/mK

Thickness mm

Rm2K/W

UW/m2K

Dimension mm

Unit/Package Price€/m2n. pieces m2

30 ● 1,07 0,93 600 x 1200 20 14,40 10,2740 ● 1,43 0,70 600 x 1200 16 11,52 12,8650 ● 1,79 0,56 600 x 1200 14 10,08 15,2360 ● 2,14 0,47 600 x 1200 12 8,64 17,6970 ● 2,50 0,40 600 x 1200 10 7,20 21,1380 ● 3,08 0,33 600 x 1200 8 5,76 23,2790 ● 3,46 0,29 600 x 1200 8 5,76 25,89

100 ● 3,85 0,26 600 x 1200 6 4,32 28,48110 ● 4,23 0,24 600 x 1200 6 4,32 31,82120 ● 4,80 0,21 600 x 1200 6 4,32 34,02140 ● 5,60 0,18 600 x 1200 6 4,32 39,55160 ● 6,40 0,16 600 x 1200 4 2,88 44,92180 ● 7,20 0,14 600 x 1200 4 2,88 50,38200 ● 8,00 0,12 600 x 1200 4 2,88 55,93

Thickness mm

Rm2K/W

UW/m2K

Dimension mm

Unit/Package Price€/m2n. pieces m2

20 ● 0,71 1,40 600 x 1200 30 21,60 7,2430 ● 1,07 0,93 600 x 1200 20 14,40 9,1240 ● 1,43 0,70 600 x 1200 16 11,52 11,2950 ● 1,79 0,56 600 x 1200 14 10,08 13,2760 ● 2,14 0,47 600 x 1200 12 8,64 15,3370 ● 2,50 0,40 600 x 1200 10 7,20 18,2780 ● 3,08 0,33 600 x 1200 8 5,76 20,0990 ● 3,46 0,29 600 x 1200 8 5,76 22,31

100 ● 3,85 0,26 600 x 1200 6 4,32 24,52110 ● 4,23 0,24 600 x 1200 6 4,32 27,46120 ● 4,80 0,21 600 x 1200 6 4,32 29,20130 ● 5,20 0,19 600 x 1200 6 4,32 31,88140 ● 5,60 0,18 600 x 1200 6 4,32 33,58160 ● 6,40 0,16 600 x 1200 4 2,88 38,64180 ● 7,20 0,14 600 x 1200 4 2,88 43,39200 ● 8,00 0,12 600 x 1200 4 2,88 48,12

da 20 a 70 mm λD = 0,028 W/mK da 80 a 110 mm λD = 0,026 W/mKda 120 a 200 mm λD = 0,025 W/mK

da 20 a 70 mm λD = 0,028 W/mK da 80 a 110 mm λD = 0,026 W/mKda 120 a 200 mm λD = 0,025 W/mK

● = standard production normally in-stock● = produced on request and time of delivery to be determined

Page 5: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for

Price list october 2014

High Performance under heavy loads

Polyiso foamFacers: bituminous glass fiber with a layer of PPE on the top side and saturated mineral fiber on the bottom sideApplications:Flat roofs under waterproofing bituminous mantles in view, fixed with a hot torch and requiring high resistance to compression.

Polyiso foamFacers: bituminous glass fiber with a layer of PPE on the top side and saturated mineral fiber on the bottom sideApplications:Flat roofs under waterproofing bituminous mantles in view, fixed with a hot torch.

PANELS

Class B

Class BH

Polyiso foamFacers: exclusive mineralized glass fiber with added mineral fiber named: FIRE B Facer® on the side more exposed to high risk of a fire and mineralized glass fiber on the other side.Applications:Insulation for ventilated wall systems.In all applications where higher fire reaction performance is required.

FIRE BFire reaction - Euroclass B s1 d0

Thickness mm

Rm2K/W

UW/m2K

Dimension mm

Unit/Package Price€/m2n. pieces m2

30 ● 1,07 0,93 600 x 1200 20 14,40 11,3340 ● 1,43 0,70 600 x 1200 16 11,52 13,8650 ● 1,79 0,56 600 x 1200 14 10,08 16,2260 ● 2,14 0,47 600 x 1200 12 8,64 18,6970 ● 2,50 0,40 600 x 1200 10 7,20 22,1080 ● 3,08 0,33 600 x 1200 8 5,76 24,3090 ● 3,46 0,29 600 x 1200 8 5,76 26,92

100 ● 3,85 0,26 600 x 1200 6 4,32 29,51110 ● 4,23 0,24 600 x 1200 6 4,32 32,85120 ● 4,80 0,21 600 x 1200 6 4,32 35,05140 ● 5,60 0,18 600 x 1200 6 4,32 40,30

Thickness mm

Rm2K/W

UW/m2K

Dimension mm

Unit/Package Price€/m2n. pieces m2

30 ● 1,07 0,93 600 x 1200 20 14,40 10,1540 ● 1,43 0,70 600 x 1200 16 11,52 12,3150 ● 1,79 0,56 600 x 1200 14 10,08 14,2760 ● 2,14 0,47 600 x 1200 12 8,64 16,3670 ● 2,50 0,40 600 x 1200 10 7,20 19,3780 ● 3,08 0,33 600 x 1200 8 5,76 21,1590 ● 3,46 0,29 600 x 1200 8 5,76 23,38

100 ● 3,85 0,26 600 x 1200 6 4,32 25,58110 ● 4,23 0,24 600 x 1200 6 4,32 28,52120 ● 4,80 0,21 600 x 1200 6 4,32 30,26130 ● 5,20 0,19 600 x 1200 6 4,32 32,94140 ● 5,60 0,18 600 x 1200 6 4,32 34,65160 ● 6,40 0,16 600 x 1200 4 2,88 39.89180 ● 7,20 0,14 600 x 1200 4 2,88 44,56200 ● 8,00 0,12 600 x 1200 4 2,88 49,29

Thickness mm

Rm2K/W

UW/m2K

Dimension mm

Unit/Package Price€/m2n. pieces m2

20 ● 0,71 1,40 600 x 1200 30 21,60 13,3830 ● 1,07 0,93 600 x 1200 20 14,40 15,6140 ● 1,43 0,70 600 x 1200 16 11,52 17,9850 ● 1,79 0,56 600 x 1200 14 10,08 20,2460 ● 2,14 0,47 600 x 1200 12 8,64 22,5770 ● 2,50 0,40 600 x 1200 10 7,20 24,8780 ● 3,08 0,33 600 x 1200 8 5,76 27,1890 ● 3,46 0,29 600 x 1200 8 5,76 29,64

100 ● 3,85 0,26 600 x 1200 6 4,32 31,96110 ● 4,23 0,24 600 x 1200 6 4,32 34,29120 ● 4,80 0,21 600 x 1200 6 4,32 36,62130 ● 5,20 0,19 600 x 1200 6 4,32 38,90140 ● 5,60 0,18 600 x 1200 6 4,32 40,88160 ● 6,40 0,16 600 x 1200 4 2,88 46,04180 ● 7,20 0,14 600 x 1200 4 2,88 50,97200 ● 8,00 0,12 600 x 1200 4 2,88 55,88

da 20 a 70 mm λD = 0,028 W/mK da 80 a 110 mm λD = 0,026 W/mKda 120 a 200 mm λD = 0,025 W/mK

da 20 a 70 mm λD = 0,028 W/mK da 80 a 110 mm λD = 0,026 W/mKda 120 a 200 mm λD = 0,025 W/mK

da 20 a 70 mm λD = 0,028 W/mK da 80 a 110 mm λD = 0,026 W/mKda 120 a 200 mm λD = 0,025 W/mK

● = standard production normally in-stock● = produced on request and time of delivery to be determined

Page 6: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for

Price list october 2014

Polyiso foamFacers:Embossed aluminium 40 µ on both sides. Applications:Insulation for heated floors, ven-tilated walls, and as wall cavity insulation where a vapour barrier is required.

* 60 and 80 m embossed aluminium facers may be substituted upon request and with minimum, quantity required.

Polyiso foamFacers:embossed aluminium 40 µ on the top side and saturated fiberglass on the bottom sideApplications:Insulation for heated floors, ven-tilated walls, and as wall cavity insulation where a vapour barrier is required.

PANELS

Polyiso foamFacers:Impregnated and reinforced paperApplications:Insulation used in ballasted or paved roofs. Floor insulation.

BB

AI 4*

AV 4*

Thickness mm

Rm2K/W

UW/m2K

Dimension mm

Unit/Package Price€/m2

n. pieces m2

20 0,87 1,15 600 x 1200 30 21,60 9,2030 1,30 0,77 600 x 1200 20 14,40 11,4840 1,74 0,58 600 x 1200 16 11,52 13,9350 2,17 0,46 600 x 1200 14 10,08 16,2660 2,61 0,38 600 x 1200 12 8,64 18,30

Thickness mm

Rm2K/W

UW/m2K

Dimension mm

Unit/Package Price€/m2

n. pieces m2

20 0,71 1,40 600 x 1200 30 21,60 8,3630 1,07 0,93 600 x 1200 20 14,40 10,4040 1,43 0,70 600 x 1200 16 11,52 12,7050 1,79 0,56 600 x 1200 14 10,08 14,7960 2,14 0,47 600 x 1200 12 8,64 17,12

Thickness mm

Rm2K/W

UW/m2K

Dimension mm

Unit/Package Price€/m2

n. pieces m2

30 ● 1,07 0,93 600 x 1200 20 14,40 9,0540 ● 1,43 0,70 600 x 1200 16 11,52 11,2950 ● 1,79 0,56 600 x 1200 14 10,08 13,32 from 30 to 50 mm λD = 0,028 W/mK

λD = 0,023 W/mK

λD = 0,023 W/mK

● = standard production normally in-stock● = produced on request and time of delivery to be determined= produced on request and minimum quantity required

Page 7: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for

Price list october 2014

Insulation panel in polyiso foam bonded to a 3 kg/m2 bitumen-polymer membrane with glass fiber reinforcement and cold weather flexibility: App -5°C.Includes two 10cm selvages on the lateral sidesApplications:Insulation and waterproofing support of flat and pitched roofs.

Insulation panel in polyiso foam bonded to a bitumen-polymer membrane of 4,5 kg/m2 and slate chips finish, reinforced with polyester non-woven fabric. Bitumen cold weather flexibility of App -10°C.Includes two 10cm selvages on the lateral sides. Applications:Insulation and waterproofing primer of flat and pitched roofs.

Insulation panel in polyiso foam bonded to a bitumen-polymer membrane of 4mm, reinforced with polyester non-woven fabric, and bitumen cold weather flexibi-lity of App -10°C.Includes two 10cm selvages on the lateral sides.Applications:Insulation and waterproofing primer of flat and pitched roofs.

GT 3

GT 4

GT 5

BONDED

● = standard production normally in-stock● = produced on request and time of delivery to be determined

Thickness mm

R*m2K/W

U*W/m2K Dimension mm

Unit/Package Price€/m2

n. pieces m2

40 ● 1,74 0,58 1200 x 1200 15 21,60 18,9750 ● 2,17 0,46 1200 x 1200 12 17,28 21,3460 ● 2,61 0,38 1200 x 1200 10 14,40 23,7670 ● 3,04 0,33 1200 x 1200 9 12,96 26,8880 ● 3,48 0,29 1200 x 1200 8 11,52 29,2790 ● 3,91 0,26 1200 x 1200 7 10,08 31,88

100 ● 4,35 0,23 1200 x 1200 6 8,64 34,46110 ● 4,78 0,21 1200 x 1200 6 8,64 37,91120 ● 5,22 0,19 1200 x 1200 5 7,20 40,30

Thickness mm

R*m2K/W

U*W/m2K Dimension mm

Unit/Package Price€/m2

n. pieces m2

40 ● 1,74 0,58 1200 x 1200 15 21,60 22,4450 ● 2,17 0,46 1200 x 1200 12 17,28 24,8060 ● 2,61 0,38 1200 x 1200 10 14,40 27,2270 ● 3,04 0,33 1200 x 1200 9 12,96 30,3780 ● 3,48 0,29 1200 x 1200 8 11,52 32,6290 ● 3,91 0,26 1200 x 1200 7 10,08 35,35

100 ● 4,35 0,23 1200 x 1200 6 8,64 37,93110 ● 4,78 0,21 1200 x 1200 6 8,64 41,38120 ● 5,22 0,19 1200 x 1200 5 7,20 43,79

Thickness mm

R*m2K/W

U*W/m2K Dimension mm

Unit/Package Price€/m2

n. pieces m2

40 ● 1,74 0,58 1200 x 1200 15 21,60 21,9250 ● 2,17 0,46 1200 x 1200 12 17,28 24,2960 ● 2,61 0,38 1200 x 1200 10 14,40 26,6870 ● 3,04 0,33 1200 x 1200 9 12,96 29,8380 ● 3,48 0,29 1200 x 1200 8 11,52 32,0890 ● 3,91 0,26 1200 x 1200 7 10,08 34,83

100 ● 4,35 0,23 1200 x 1200 6 8,64 37,38110 ● 4,78 0,21 1200 x 1200 6 8,64 40,86120 ● 5,22 0,19 1200 x 1200 5 7,20 43,25

Insulation panelλD = 0,023 W/mK

Insulation panelλD = 0,023 W/mK

Insulation panelλD = 0,023 W/mK

The insulation panel can be supplied with a different type of bonded support upon request and quantity to be determined.

Page 8: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for

Price list october 2014

* Also available with plasterboard of 9,5 mm.

R* and U* values refer to the insulation component only.

GTC panel bonded to 12,50 mm* plasterboard.Applications:Insulation of internal walls and ceilings.

GTE panel bonded to 12,50 mm* plasterboard.Applications:Insulation of internal walls and ceilings.

PLASTERBOARD

BONDED

PLASTERBOARD

Thickness mm R*m2K/W

U*W/m2K

Dimension mm

Unit/PackagePrice€/m2n.

pieces m2Tot. PU +Plasteboard*

33 20 + 13 ● 0,87 1,15 1200 x 3000 – – 13,9143 30 + 13 ● 1,30 0,77 1200 x 3000 – – 16,1553 40 + 13 ● 1,74 0,58 1200 x 3000 – – 18,3963 50 + 13 ● 2,17 0,46 1200 x 3000 – – 20,5673 60 + 13 ● 2,61 0,38 1200 x 3000 – – 22,7583 70 + 13 ● 3,04 0,33 1200 x 3000 – – 25,6693 80 + 13 ● 3,48 0,29 1200 x 3000 – – 27,74103 90 + 13 ● 3,91 0,26 1200 x 3000 – – 30,17113 100 + 13 ● 4,35 0,23 1200 x 3000 – – 32,51123 110 + 13 ● 4,78 0,21 1200 x 3000 – – 35,76133 120 + 13 ● 5,22 0,19 1200 x 3000 – – 37,94

Thickness mm R*m2K/W

U*W/m2K

Dimension mm

Unit/Package Price€/m2n.

pieces m2Tot. PU +Plasteboard*

33 20 + 13 ● 0,87 1,15 1200 x 3000 – – 15,7443 30 + 13 ● 1,30 0,77 1200 x 3000 – – 17,9853 40 + 13 ● 1,74 0,58 1200 x 3000 – – 20,2963 50 + 13 ● 2,17 0,46 1200 x 3000 – – 22,5073 60 + 13 ● 2,61 0,38 1200 x 3000 – – 24,7483 70 + 13 ● 3,04 0,33 1200 x 3000 – – 27,8293 80 + 13 ● 3,48 0,29 1200 x 3000 – – 29,80

103 90 + 13 ● 3,91 0,26 1200 x 3000 – – 32,26113 100 + 13 ● 4,35 0,23 1200 x 3000 – – 34,76123 110 + 13 ● 4,78 0,21 1200 x 3000 – – 37,85133 120 + 13 ● 5,22 0,19 1200 x 3000 – – 39,82

RP 1

RP 3

GTC panelλD = 0,023 W/mK

GTE panelλD = 0,023 W/mK

● = standard production normally in-stock● = produced on request and time of delivery to be determined

Page 9: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for

Price list october 2014

Band self-adhesive sealing stripAdhesive tape in PE with special foil with acrylic glue. (consider 1,5 ml for every square meter of surface)

widthcm

lengthml

Unit/Packagen. rolls

Price€/ml

10 25 8 1,37

New omega zinc profile with increased ventilationZinc Magnesium omega profile with increased ventilation. Distance between the rows of zinc profiles is determined by the length of the tiles. (Consider 3 ml for every square meter of surface)

heightcm

lenghtml

Price€/ml

3,8 2,40 3,22

Isoband

Ridge vent in painted aluminium with holes for airflow and ventilation of ridges. Length 5 ml

heightcm

Price€/ml

40 10,50

Ridge batten braces

Ridge batten braces for ventilated ridgesPrice€/ea

2,10

Universal Bird Block

Bird block in zinc sheet metal, 4 cm in height and 2 ml in lengthPrice€/ml

4,33

Combed Bird Block

Bird Block in polypropylene with two rows of teeth, offset. Length 1 ml

heightcm

Price€/cad

7 1,49

11 1,74

Raised Combed Bird Block

Bird Block in polypropylene with two rows of teeth, offset. Length 1 ml

heightcm

Price€/cad

7 1,98

11 2,11

Polyurethane foamFacers:Laminglass permeable to vapour and impermeable to water. Laths incorporated in the foam to avoid thermo bridges.Applications:Ventilated and micro-ventilated pitched roofs.

SYSTEMS

ISOVENTILATO

Installation accessories

Thickness mm

Rm2K/W

UW/m2K

Dimension mm

Unit/Package Price€/m2n. pieces m2

50 ●B 1,79 0,56 1200 x 2400 5 14,40 18,3660 ●B 2,14 0,47 1200 x 2400 5 14,40 20,7770 ●B 2,50 0,40 1200 x 2400 5 14,40 23,8380 ●B 3,08 0,33 1200 x 2400 4 11,52 25,7490 ●B 3,46 0,29 1200 x 2400 4 11,52 28,08

100 ●B 3,85 0,26 1200 x 2400 4 11,52 30,46110 ●B 4,23 0,24 1200 x 2400 3 8,64 33,44120 ●B 4,62 0,22 1200 x 2400 3 8,64 35,47130 ●B 5,00 0,20 1200 x 2400 3 8,64 37,60140 ●B 5,38 0,19 1200 x 2400 3 8,64 39,90

da 20 a 70 mm λD = 0,028 W/mK da 80 a 110 mm λD = 0,026 W/mKda 120 a 200 mm λD = 0,025 W/mK

● = standard production normally in-stock● = produced on request and time of delivery to be determined

Page 10: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for

Price list october 2014

The following special processing is available upon request and with a mini-mum order to be determined:

Sloped panels also pre-bonded to waterproofing membranes.

Panels cut to size

Battening on all four sides

Shapes of panels to size

Circular sections

Engravings and cuts

Panels may be bonded to bitumen-membrances of various weight and re-inforcements

Bonded to rigid supports

For more information and pricing, please contact Stiferite’s technical sales office.

Special processing

SYSTEMS

Insulation panel in polyiso foam bonded to unidirectional venti-lation laths and OSB3 of 12mm thick.Applications:Insulation of ventilated pitched roofs.

OSB 3, 12 mm thickGT Wind

R* and U* values refer to the insulation component only.

Spessore mmR*

m2K/WU*

W/m2KDimensioni

mm

Confezione€/m2

IVA esclusa

n. pezzi m2Totale

PU + Camera ventilazione +

lastra OSB392 40 + 40 + 12 ●B 1,74 0,58 585 x 1200 28 19,66 29,31102 50 + 40 + 12 ●B 2,17 0,46 585 x 1200 24 16,85 31,46112 60 + 40 + 12 ●B 2,61 0,38 585 x 1200 22 15,44 33,70122 70 + 40 + 12 ●B 3,04 0,33 585 x 1200 20 14,04 36,55132 80 + 40 + 12 ●B 3,48 0,29 585 x 1200 18 12,64 38,67142 90 + 40 + 12 ●B 3,91 0,26 585 x 1200 18 12,64 41,04152 100 + 40 + 12 ●B 4,35 0,23 585 x 1200 16 11,23 43,45162 110 + 40 + 12 ●B 4,78 0,21 585 x 1200 14 9,83 46,84172 120 + 40 + 12 ●B 5,22 0,19 585 x 1200 14 9,83 48,96

Insulation panelλD = 0,023 W/mK

● = standard production normally in-stock● = produced on request and time of delivery to be determined

Page 11: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for

Price list october 2014

More product information (applications’ schemes, industrial tolerances, performance and technical characteristics, etc.)is available in Stiferite’s technical documentation.Depliants and technical data sheets may be requested from our Technical Sales office or downloaded from our website: www.stiferite.com

Technical Sales office:

Stiferite SrlViale Navigazione Interna, 54 35129 - Padova, Italy

Tel + 39 049 8997911Fax + 39 049 774727email [email protected] [email protected]

Date Notes

Notes and purchase details

Contact

Technical information:

Page 12: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for

stud

ioem

me

VI -

01.

14 -

300

- G.V

.

Stiferite Srl Viale della Navigazione Interna, 54 - 35129 Padova, ItalyTel. +39 049 8997911 - Fax +39 049 774727 email: [email protected] [email protected]

Download Stiferite’s APPAvailabe in Iphone, Ipad e Android versions