Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal...
Transcript of Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal...
![Page 1: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for](https://reader034.fdocuments.in/reader034/viewer/2022050101/5f401f3e21c4805b221f99fe/html5/thumbnails/1.jpg)
Pane
ls a
nd
the
rmo
insu
latio
n s
yste
ms
Pri
ce
Lis
to
cto
be
r 2
014
Thicknesses
up to 200mm
![Page 2: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for](https://reader034.fdocuments.in/reader034/viewer/2022050101/5f401f3e21c4805b221f99fe/html5/thumbnails/2.jpg)
Price list october 2014
● = standard production normally in-stock● = produced on request and time of delivery to be determined= produced on request and minimum quantity required
Sizes a thicknesses from those indicated are produced on request and minimum quantity required.B = Panels with rabbets along the long sidesR = Thermal Resistence expressed in m2K/W, derived from the thermal conductivity value (λD)U = Thermal Trasmittance expressed in W/m2K, derived from the thermal conductivity value (λD)N.B. All Stiferite’s panels thicker than 20mm, may be produced with rabbets along the sides, upon request.
Packaging: Stiferite’s panel are packaged in closed packs of thermoplastic.Delivery: Ex-works from our warehouse in Padova, ItalyTransport: Delivery by trucks of 60-100 cubic meters is available upon request. Lesser quantities (minimum 15 cubic meters) may be delivered by groupage. Label: All packs carry a label with the following information: Name and abbreviation of the product, thickness, size, number of pieces, quantity in square meters, date of production and technical data as required by the CE marking procedure.Stocking: Panels must be off the ground and inside a dry area if stored for an extended period.Modifications: At any moment and without prior notice, Stiferite Srl reserves the right to make changes to the characteristics and the prices of the products reported in this price list.Rabbeting: The rabbets along the sides will cause a reduction of panel width of approximately 12 mm.
For further information on the type of product most suitable for a specific application, refer to the techni-cal documentation available also on-line at http://www.stiferite.com. The following table is only for the more common applications.
Legend
Indications and instructions
Main applications
Clas
s B
- B
H
Clas
s S
- SH
Clas
s SK
Fire
B
GT
GTE
AI4
GT3
- G
T4 -
GT5
RP1
- R
P3
Isov
entil
ato
GT
Win
d
ROOFS
Flat under waterproofing bituminous mantles in view, fixed with hot torch • • •Flat under waterproofing synthetic mantles in view, glued or mechanically fixed • • •Flat under ballasted or paved roofs • • • • •Under flat driveway roof • •Pitched under clay tiles or sheet metal • • • • • •Pitched under a full or micro-ventilated system • • • • •WALLS
In cavities • • • •Internal bump resistive walls • • • • •External Thermal Insulation or ETIC Systems •External ventilated facade systems • • • • •Thermal Bridge Free •FLOORS
Civil or industrial floors • • •Heated floors • • •Civil or industrial floors • • • •
![Page 3: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for](https://reader034.fdocuments.in/reader034/viewer/2022050101/5f401f3e21c4805b221f99fe/html5/thumbnails/3.jpg)
Price list october 2014
Polyiso foamFacers:Duotwin®
Applications:Roof insulationInsulation for walls and floors
Thickness mm
Rm2K/W
UW/m2K
Dimension mm
Unit/Package Price€/m2
n. pieces m2
20 ● 0,87 1,15 600 x 1200 30 21,60 7,17
30 ● 1,30 0,77 600 x 1200 20 14,40 9,17
40 ● 1,74 0,58 600 x 1200 16 11,52 11,22
40 ●B 1,74 0,58 1200 x 2800 6 20,16 11,22
50 ● 2,17 0,46 600 x 1200 14 10,08 13,17
50 ●B 2,17 0,46 1200 x 2800 5 16,80 13,17
60 ● 2,61 0,38 600 x 1200 12 8,64 15,15
60 ●B 2,61 0,38 1200 x 2800 4 13,44 15,15
70 ● 3,04 0,33 600 x 1200 10 7,20 17,92
80 ● 3,48 0,29 600 x 1200 8 5,76 19,72
90 ● 3,91 0,26 600 x 1200 8 5,76 21,99
100 ● 4,35 0,23 600 x 1200 6 4,32 24,16
110 ● 4,78 0,21 600 x 1200 6 4,32 27,34
120 ● 5,22 0,19 600 x 1200 6 4,32 29,32
FACER DUOTWIN®
Polyiso foamFacers:Multi-layer aluminium reinforced with glass netting on both sides, for improved adhesiveness to the braces used in installation of heated floor systems.Applications:Roof insulationRoof insulationInsulation for walls and floorsInsulation for “ventilated facades” Resistence to vapour factor: u>8990
Thickness mm
Rm2K/W
UW/m2K
Dimension mm
Unit/Package Price€/m2
n. pieces m2
20 ● 0,87 1,15 600 x 1200 30 21,60 7,31
30 ● 1,30 0,77 600 x 1200 20 14,40 9,36
40 ● 1,74 0,58 600 x 1200 16 11,52 11,46
50 ● 2,17 0,46 600 x 1200 14 10,08 13,46
60 ● 2,61 0,38 600 x 1200 12 8,64 15,48
70 ● 3,04 0,33 600 x 1200 10 7,20 18,45
80 ● 3,48 0,29 600 x 1200 8 5,76 20,16
90 ● 3,91 0,26 600 x 1200 8 5,76 22,47
100 ● 4,35 0,23 600 x 1200 6 4,32 24,82
110 ● 4,78 0,21 600 x 1200 6 4,32 27,82
120 ● 5,22 0,19 600 x 1200 6 4,32 29,53
MULTI-LAYER ALUMINIUM FACER
GT
GTE
PANELS
● = standard production normally in-stock● = produced on request and time of delivery to be determined
NEW
λD = 0,023 W/mK
λD = 0,023 W/mK
![Page 4: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for](https://reader034.fdocuments.in/reader034/viewer/2022050101/5f401f3e21c4805b221f99fe/html5/thumbnails/4.jpg)
Price list october 2014
High Performance under heavy loads
Polyiso foamFacers: saturated glass fiberApplications:Flat roofs under waterproofing synthetic or bituminous mantles in view, glued or mechanically fixed. Insulation for floors requiring highresistance to compression.
Polyiso foamFacers: saturated glass fiberApplications: External insulation for “ETIC Systems” and “ventila-ted facades”Insulation used to eliminate “Thermal Bridges”Panel is also available upon request and only in thicknesses of 80mm-200mm for use in Mechanical ETICSystems.
SPECIAL FOR ETICS SYSTEMS
Polyiso foamFacers:saturated glass fiberApplications:Flat roofs under waterproofing synthetic or bituminous mantles in view, glued or mechanically fixed
PANELS
Class SK
Class S
Class SH
Thickness mm
Rm2K/W
UW/m2K
Dimension mm
Unit/Package Price€/m2n. pieces m2
20 ● 0,71 1,40 600 x 1200 30 21,60 7,4130 ● 1,07 0,93 600 x 1200 20 14,40 9,3340 ● 1,43 0,70 600 x 1200 16 11,52 11,5550 ● 1,79 0,56 600 x 1200 14 10,08 13,5860 ● 2,14 0,47 600 x 1200 12 8,64 15,6870 ● 2,50 0,40 600 x 1200 10 7,20 18,6980 ● 3,08 0,33 600 x 1200 8 5,76 20,5590 ● 3,46 0,29 600 x 1200 8 5,76 22,83
100 ● 3,85 0,26 600 x 1200 6 4,32 25,08110 ● 4,23 0,24 600 x 1200 6 4,32 28,09120 ● 4,80 0,21 600 x 1200 6 4,32 29,87130 ● 5,20 0,19 600 x 1200 6 4,32 32,61140 ● 5,60 0,18 600 x 1200 6 4,32 34,36160 ● 6,40 0,16 600 x 1200 4 2,88 38,70180 ● 7,20 0,14 600 x 1200 4 2,88 43,45200 ● 8,00 0,12 600 x 1200 4 2,88 48,20
da 20 a 70 mm λD = 0,028 W/mK da 80 a 110 mm λD = 0,026 W/mKda 120 a 200 mm λD = 0,025 W/mK
Thickness mm
Rm2K/W
UW/m2K
Dimension mm
Unit/Package Price€/m2n. pieces m2
30 ● 1,07 0,93 600 x 1200 20 14,40 10,2740 ● 1,43 0,70 600 x 1200 16 11,52 12,8650 ● 1,79 0,56 600 x 1200 14 10,08 15,2360 ● 2,14 0,47 600 x 1200 12 8,64 17,6970 ● 2,50 0,40 600 x 1200 10 7,20 21,1380 ● 3,08 0,33 600 x 1200 8 5,76 23,2790 ● 3,46 0,29 600 x 1200 8 5,76 25,89
100 ● 3,85 0,26 600 x 1200 6 4,32 28,48110 ● 4,23 0,24 600 x 1200 6 4,32 31,82120 ● 4,80 0,21 600 x 1200 6 4,32 34,02140 ● 5,60 0,18 600 x 1200 6 4,32 39,55160 ● 6,40 0,16 600 x 1200 4 2,88 44,92180 ● 7,20 0,14 600 x 1200 4 2,88 50,38200 ● 8,00 0,12 600 x 1200 4 2,88 55,93
Thickness mm
Rm2K/W
UW/m2K
Dimension mm
Unit/Package Price€/m2n. pieces m2
20 ● 0,71 1,40 600 x 1200 30 21,60 7,2430 ● 1,07 0,93 600 x 1200 20 14,40 9,1240 ● 1,43 0,70 600 x 1200 16 11,52 11,2950 ● 1,79 0,56 600 x 1200 14 10,08 13,2760 ● 2,14 0,47 600 x 1200 12 8,64 15,3370 ● 2,50 0,40 600 x 1200 10 7,20 18,2780 ● 3,08 0,33 600 x 1200 8 5,76 20,0990 ● 3,46 0,29 600 x 1200 8 5,76 22,31
100 ● 3,85 0,26 600 x 1200 6 4,32 24,52110 ● 4,23 0,24 600 x 1200 6 4,32 27,46120 ● 4,80 0,21 600 x 1200 6 4,32 29,20130 ● 5,20 0,19 600 x 1200 6 4,32 31,88140 ● 5,60 0,18 600 x 1200 6 4,32 33,58160 ● 6,40 0,16 600 x 1200 4 2,88 38,64180 ● 7,20 0,14 600 x 1200 4 2,88 43,39200 ● 8,00 0,12 600 x 1200 4 2,88 48,12
da 20 a 70 mm λD = 0,028 W/mK da 80 a 110 mm λD = 0,026 W/mKda 120 a 200 mm λD = 0,025 W/mK
da 20 a 70 mm λD = 0,028 W/mK da 80 a 110 mm λD = 0,026 W/mKda 120 a 200 mm λD = 0,025 W/mK
● = standard production normally in-stock● = produced on request and time of delivery to be determined
![Page 5: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for](https://reader034.fdocuments.in/reader034/viewer/2022050101/5f401f3e21c4805b221f99fe/html5/thumbnails/5.jpg)
Price list october 2014
High Performance under heavy loads
Polyiso foamFacers: bituminous glass fiber with a layer of PPE on the top side and saturated mineral fiber on the bottom sideApplications:Flat roofs under waterproofing bituminous mantles in view, fixed with a hot torch and requiring high resistance to compression.
Polyiso foamFacers: bituminous glass fiber with a layer of PPE on the top side and saturated mineral fiber on the bottom sideApplications:Flat roofs under waterproofing bituminous mantles in view, fixed with a hot torch.
PANELS
Class B
Class BH
Polyiso foamFacers: exclusive mineralized glass fiber with added mineral fiber named: FIRE B Facer® on the side more exposed to high risk of a fire and mineralized glass fiber on the other side.Applications:Insulation for ventilated wall systems.In all applications where higher fire reaction performance is required.
FIRE BFire reaction - Euroclass B s1 d0
Thickness mm
Rm2K/W
UW/m2K
Dimension mm
Unit/Package Price€/m2n. pieces m2
30 ● 1,07 0,93 600 x 1200 20 14,40 11,3340 ● 1,43 0,70 600 x 1200 16 11,52 13,8650 ● 1,79 0,56 600 x 1200 14 10,08 16,2260 ● 2,14 0,47 600 x 1200 12 8,64 18,6970 ● 2,50 0,40 600 x 1200 10 7,20 22,1080 ● 3,08 0,33 600 x 1200 8 5,76 24,3090 ● 3,46 0,29 600 x 1200 8 5,76 26,92
100 ● 3,85 0,26 600 x 1200 6 4,32 29,51110 ● 4,23 0,24 600 x 1200 6 4,32 32,85120 ● 4,80 0,21 600 x 1200 6 4,32 35,05140 ● 5,60 0,18 600 x 1200 6 4,32 40,30
Thickness mm
Rm2K/W
UW/m2K
Dimension mm
Unit/Package Price€/m2n. pieces m2
30 ● 1,07 0,93 600 x 1200 20 14,40 10,1540 ● 1,43 0,70 600 x 1200 16 11,52 12,3150 ● 1,79 0,56 600 x 1200 14 10,08 14,2760 ● 2,14 0,47 600 x 1200 12 8,64 16,3670 ● 2,50 0,40 600 x 1200 10 7,20 19,3780 ● 3,08 0,33 600 x 1200 8 5,76 21,1590 ● 3,46 0,29 600 x 1200 8 5,76 23,38
100 ● 3,85 0,26 600 x 1200 6 4,32 25,58110 ● 4,23 0,24 600 x 1200 6 4,32 28,52120 ● 4,80 0,21 600 x 1200 6 4,32 30,26130 ● 5,20 0,19 600 x 1200 6 4,32 32,94140 ● 5,60 0,18 600 x 1200 6 4,32 34,65160 ● 6,40 0,16 600 x 1200 4 2,88 39.89180 ● 7,20 0,14 600 x 1200 4 2,88 44,56200 ● 8,00 0,12 600 x 1200 4 2,88 49,29
Thickness mm
Rm2K/W
UW/m2K
Dimension mm
Unit/Package Price€/m2n. pieces m2
20 ● 0,71 1,40 600 x 1200 30 21,60 13,3830 ● 1,07 0,93 600 x 1200 20 14,40 15,6140 ● 1,43 0,70 600 x 1200 16 11,52 17,9850 ● 1,79 0,56 600 x 1200 14 10,08 20,2460 ● 2,14 0,47 600 x 1200 12 8,64 22,5770 ● 2,50 0,40 600 x 1200 10 7,20 24,8780 ● 3,08 0,33 600 x 1200 8 5,76 27,1890 ● 3,46 0,29 600 x 1200 8 5,76 29,64
100 ● 3,85 0,26 600 x 1200 6 4,32 31,96110 ● 4,23 0,24 600 x 1200 6 4,32 34,29120 ● 4,80 0,21 600 x 1200 6 4,32 36,62130 ● 5,20 0,19 600 x 1200 6 4,32 38,90140 ● 5,60 0,18 600 x 1200 6 4,32 40,88160 ● 6,40 0,16 600 x 1200 4 2,88 46,04180 ● 7,20 0,14 600 x 1200 4 2,88 50,97200 ● 8,00 0,12 600 x 1200 4 2,88 55,88
da 20 a 70 mm λD = 0,028 W/mK da 80 a 110 mm λD = 0,026 W/mKda 120 a 200 mm λD = 0,025 W/mK
da 20 a 70 mm λD = 0,028 W/mK da 80 a 110 mm λD = 0,026 W/mKda 120 a 200 mm λD = 0,025 W/mK
da 20 a 70 mm λD = 0,028 W/mK da 80 a 110 mm λD = 0,026 W/mKda 120 a 200 mm λD = 0,025 W/mK
● = standard production normally in-stock● = produced on request and time of delivery to be determined
![Page 6: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for](https://reader034.fdocuments.in/reader034/viewer/2022050101/5f401f3e21c4805b221f99fe/html5/thumbnails/6.jpg)
Price list october 2014
Polyiso foamFacers:Embossed aluminium 40 µ on both sides. Applications:Insulation for heated floors, ven-tilated walls, and as wall cavity insulation where a vapour barrier is required.
* 60 and 80 m embossed aluminium facers may be substituted upon request and with minimum, quantity required.
Polyiso foamFacers:embossed aluminium 40 µ on the top side and saturated fiberglass on the bottom sideApplications:Insulation for heated floors, ven-tilated walls, and as wall cavity insulation where a vapour barrier is required.
PANELS
Polyiso foamFacers:Impregnated and reinforced paperApplications:Insulation used in ballasted or paved roofs. Floor insulation.
BB
AI 4*
AV 4*
Thickness mm
Rm2K/W
UW/m2K
Dimension mm
Unit/Package Price€/m2
n. pieces m2
20 0,87 1,15 600 x 1200 30 21,60 9,2030 1,30 0,77 600 x 1200 20 14,40 11,4840 1,74 0,58 600 x 1200 16 11,52 13,9350 2,17 0,46 600 x 1200 14 10,08 16,2660 2,61 0,38 600 x 1200 12 8,64 18,30
Thickness mm
Rm2K/W
UW/m2K
Dimension mm
Unit/Package Price€/m2
n. pieces m2
20 0,71 1,40 600 x 1200 30 21,60 8,3630 1,07 0,93 600 x 1200 20 14,40 10,4040 1,43 0,70 600 x 1200 16 11,52 12,7050 1,79 0,56 600 x 1200 14 10,08 14,7960 2,14 0,47 600 x 1200 12 8,64 17,12
Thickness mm
Rm2K/W
UW/m2K
Dimension mm
Unit/Package Price€/m2
n. pieces m2
30 ● 1,07 0,93 600 x 1200 20 14,40 9,0540 ● 1,43 0,70 600 x 1200 16 11,52 11,2950 ● 1,79 0,56 600 x 1200 14 10,08 13,32 from 30 to 50 mm λD = 0,028 W/mK
λD = 0,023 W/mK
λD = 0,023 W/mK
● = standard production normally in-stock● = produced on request and time of delivery to be determined= produced on request and minimum quantity required
![Page 7: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for](https://reader034.fdocuments.in/reader034/viewer/2022050101/5f401f3e21c4805b221f99fe/html5/thumbnails/7.jpg)
Price list october 2014
Insulation panel in polyiso foam bonded to a 3 kg/m2 bitumen-polymer membrane with glass fiber reinforcement and cold weather flexibility: App -5°C.Includes two 10cm selvages on the lateral sidesApplications:Insulation and waterproofing support of flat and pitched roofs.
Insulation panel in polyiso foam bonded to a bitumen-polymer membrane of 4,5 kg/m2 and slate chips finish, reinforced with polyester non-woven fabric. Bitumen cold weather flexibility of App -10°C.Includes two 10cm selvages on the lateral sides. Applications:Insulation and waterproofing primer of flat and pitched roofs.
Insulation panel in polyiso foam bonded to a bitumen-polymer membrane of 4mm, reinforced with polyester non-woven fabric, and bitumen cold weather flexibi-lity of App -10°C.Includes two 10cm selvages on the lateral sides.Applications:Insulation and waterproofing primer of flat and pitched roofs.
GT 3
GT 4
GT 5
BONDED
● = standard production normally in-stock● = produced on request and time of delivery to be determined
Thickness mm
R*m2K/W
U*W/m2K Dimension mm
Unit/Package Price€/m2
n. pieces m2
40 ● 1,74 0,58 1200 x 1200 15 21,60 18,9750 ● 2,17 0,46 1200 x 1200 12 17,28 21,3460 ● 2,61 0,38 1200 x 1200 10 14,40 23,7670 ● 3,04 0,33 1200 x 1200 9 12,96 26,8880 ● 3,48 0,29 1200 x 1200 8 11,52 29,2790 ● 3,91 0,26 1200 x 1200 7 10,08 31,88
100 ● 4,35 0,23 1200 x 1200 6 8,64 34,46110 ● 4,78 0,21 1200 x 1200 6 8,64 37,91120 ● 5,22 0,19 1200 x 1200 5 7,20 40,30
Thickness mm
R*m2K/W
U*W/m2K Dimension mm
Unit/Package Price€/m2
n. pieces m2
40 ● 1,74 0,58 1200 x 1200 15 21,60 22,4450 ● 2,17 0,46 1200 x 1200 12 17,28 24,8060 ● 2,61 0,38 1200 x 1200 10 14,40 27,2270 ● 3,04 0,33 1200 x 1200 9 12,96 30,3780 ● 3,48 0,29 1200 x 1200 8 11,52 32,6290 ● 3,91 0,26 1200 x 1200 7 10,08 35,35
100 ● 4,35 0,23 1200 x 1200 6 8,64 37,93110 ● 4,78 0,21 1200 x 1200 6 8,64 41,38120 ● 5,22 0,19 1200 x 1200 5 7,20 43,79
Thickness mm
R*m2K/W
U*W/m2K Dimension mm
Unit/Package Price€/m2
n. pieces m2
40 ● 1,74 0,58 1200 x 1200 15 21,60 21,9250 ● 2,17 0,46 1200 x 1200 12 17,28 24,2960 ● 2,61 0,38 1200 x 1200 10 14,40 26,6870 ● 3,04 0,33 1200 x 1200 9 12,96 29,8380 ● 3,48 0,29 1200 x 1200 8 11,52 32,0890 ● 3,91 0,26 1200 x 1200 7 10,08 34,83
100 ● 4,35 0,23 1200 x 1200 6 8,64 37,38110 ● 4,78 0,21 1200 x 1200 6 8,64 40,86120 ● 5,22 0,19 1200 x 1200 5 7,20 43,25
Insulation panelλD = 0,023 W/mK
Insulation panelλD = 0,023 W/mK
Insulation panelλD = 0,023 W/mK
The insulation panel can be supplied with a different type of bonded support upon request and quantity to be determined.
![Page 8: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for](https://reader034.fdocuments.in/reader034/viewer/2022050101/5f401f3e21c4805b221f99fe/html5/thumbnails/8.jpg)
Price list october 2014
* Also available with plasterboard of 9,5 mm.
R* and U* values refer to the insulation component only.
GTC panel bonded to 12,50 mm* plasterboard.Applications:Insulation of internal walls and ceilings.
GTE panel bonded to 12,50 mm* plasterboard.Applications:Insulation of internal walls and ceilings.
PLASTERBOARD
BONDED
PLASTERBOARD
Thickness mm R*m2K/W
U*W/m2K
Dimension mm
Unit/PackagePrice€/m2n.
pieces m2Tot. PU +Plasteboard*
33 20 + 13 ● 0,87 1,15 1200 x 3000 – – 13,9143 30 + 13 ● 1,30 0,77 1200 x 3000 – – 16,1553 40 + 13 ● 1,74 0,58 1200 x 3000 – – 18,3963 50 + 13 ● 2,17 0,46 1200 x 3000 – – 20,5673 60 + 13 ● 2,61 0,38 1200 x 3000 – – 22,7583 70 + 13 ● 3,04 0,33 1200 x 3000 – – 25,6693 80 + 13 ● 3,48 0,29 1200 x 3000 – – 27,74103 90 + 13 ● 3,91 0,26 1200 x 3000 – – 30,17113 100 + 13 ● 4,35 0,23 1200 x 3000 – – 32,51123 110 + 13 ● 4,78 0,21 1200 x 3000 – – 35,76133 120 + 13 ● 5,22 0,19 1200 x 3000 – – 37,94
Thickness mm R*m2K/W
U*W/m2K
Dimension mm
Unit/Package Price€/m2n.
pieces m2Tot. PU +Plasteboard*
33 20 + 13 ● 0,87 1,15 1200 x 3000 – – 15,7443 30 + 13 ● 1,30 0,77 1200 x 3000 – – 17,9853 40 + 13 ● 1,74 0,58 1200 x 3000 – – 20,2963 50 + 13 ● 2,17 0,46 1200 x 3000 – – 22,5073 60 + 13 ● 2,61 0,38 1200 x 3000 – – 24,7483 70 + 13 ● 3,04 0,33 1200 x 3000 – – 27,8293 80 + 13 ● 3,48 0,29 1200 x 3000 – – 29,80
103 90 + 13 ● 3,91 0,26 1200 x 3000 – – 32,26113 100 + 13 ● 4,35 0,23 1200 x 3000 – – 34,76123 110 + 13 ● 4,78 0,21 1200 x 3000 – – 37,85133 120 + 13 ● 5,22 0,19 1200 x 3000 – – 39,82
RP 1
RP 3
GTC panelλD = 0,023 W/mK
GTE panelλD = 0,023 W/mK
● = standard production normally in-stock● = produced on request and time of delivery to be determined
![Page 9: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for](https://reader034.fdocuments.in/reader034/viewer/2022050101/5f401f3e21c4805b221f99fe/html5/thumbnails/9.jpg)
Price list october 2014
Band self-adhesive sealing stripAdhesive tape in PE with special foil with acrylic glue. (consider 1,5 ml for every square meter of surface)
widthcm
lengthml
Unit/Packagen. rolls
Price€/ml
10 25 8 1,37
New omega zinc profile with increased ventilationZinc Magnesium omega profile with increased ventilation. Distance between the rows of zinc profiles is determined by the length of the tiles. (Consider 3 ml for every square meter of surface)
heightcm
lenghtml
Price€/ml
3,8 2,40 3,22
Isoband
Ridge vent in painted aluminium with holes for airflow and ventilation of ridges. Length 5 ml
heightcm
Price€/ml
40 10,50
Ridge batten braces
Ridge batten braces for ventilated ridgesPrice€/ea
2,10
Universal Bird Block
Bird block in zinc sheet metal, 4 cm in height and 2 ml in lengthPrice€/ml
4,33
Combed Bird Block
Bird Block in polypropylene with two rows of teeth, offset. Length 1 ml
heightcm
Price€/cad
7 1,49
11 1,74
Raised Combed Bird Block
Bird Block in polypropylene with two rows of teeth, offset. Length 1 ml
heightcm
Price€/cad
7 1,98
11 2,11
Polyurethane foamFacers:Laminglass permeable to vapour and impermeable to water. Laths incorporated in the foam to avoid thermo bridges.Applications:Ventilated and micro-ventilated pitched roofs.
SYSTEMS
ISOVENTILATO
Installation accessories
Thickness mm
Rm2K/W
UW/m2K
Dimension mm
Unit/Package Price€/m2n. pieces m2
50 ●B 1,79 0,56 1200 x 2400 5 14,40 18,3660 ●B 2,14 0,47 1200 x 2400 5 14,40 20,7770 ●B 2,50 0,40 1200 x 2400 5 14,40 23,8380 ●B 3,08 0,33 1200 x 2400 4 11,52 25,7490 ●B 3,46 0,29 1200 x 2400 4 11,52 28,08
100 ●B 3,85 0,26 1200 x 2400 4 11,52 30,46110 ●B 4,23 0,24 1200 x 2400 3 8,64 33,44120 ●B 4,62 0,22 1200 x 2400 3 8,64 35,47130 ●B 5,00 0,20 1200 x 2400 3 8,64 37,60140 ●B 5,38 0,19 1200 x 2400 3 8,64 39,90
da 20 a 70 mm λD = 0,028 W/mK da 80 a 110 mm λD = 0,026 W/mKda 120 a 200 mm λD = 0,025 W/mK
● = standard production normally in-stock● = produced on request and time of delivery to be determined
![Page 10: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for](https://reader034.fdocuments.in/reader034/viewer/2022050101/5f401f3e21c4805b221f99fe/html5/thumbnails/10.jpg)
Price list october 2014
The following special processing is available upon request and with a mini-mum order to be determined:
Sloped panels also pre-bonded to waterproofing membranes.
Panels cut to size
Battening on all four sides
Shapes of panels to size
Circular sections
Engravings and cuts
Panels may be bonded to bitumen-membrances of various weight and re-inforcements
Bonded to rigid supports
For more information and pricing, please contact Stiferite’s technical sales office.
Special processing
SYSTEMS
Insulation panel in polyiso foam bonded to unidirectional venti-lation laths and OSB3 of 12mm thick.Applications:Insulation of ventilated pitched roofs.
OSB 3, 12 mm thickGT Wind
R* and U* values refer to the insulation component only.
Spessore mmR*
m2K/WU*
W/m2KDimensioni
mm
Confezione€/m2
IVA esclusa
n. pezzi m2Totale
PU + Camera ventilazione +
lastra OSB392 40 + 40 + 12 ●B 1,74 0,58 585 x 1200 28 19,66 29,31102 50 + 40 + 12 ●B 2,17 0,46 585 x 1200 24 16,85 31,46112 60 + 40 + 12 ●B 2,61 0,38 585 x 1200 22 15,44 33,70122 70 + 40 + 12 ●B 3,04 0,33 585 x 1200 20 14,04 36,55132 80 + 40 + 12 ●B 3,48 0,29 585 x 1200 18 12,64 38,67142 90 + 40 + 12 ●B 3,91 0,26 585 x 1200 18 12,64 41,04152 100 + 40 + 12 ●B 4,35 0,23 585 x 1200 16 11,23 43,45162 110 + 40 + 12 ●B 4,78 0,21 585 x 1200 14 9,83 46,84172 120 + 40 + 12 ●B 5,22 0,19 585 x 1200 14 9,83 48,96
Insulation panelλD = 0,023 W/mK
● = standard production normally in-stock● = produced on request and time of delivery to be determined
![Page 11: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for](https://reader034.fdocuments.in/reader034/viewer/2022050101/5f401f3e21c4805b221f99fe/html5/thumbnails/11.jpg)
Price list october 2014
More product information (applications’ schemes, industrial tolerances, performance and technical characteristics, etc.)is available in Stiferite’s technical documentation.Depliants and technical data sheets may be requested from our Technical Sales office or downloaded from our website: www.stiferite.com
Technical Sales office:
Stiferite SrlViale Navigazione Interna, 54 35129 - Padova, Italy
Tel + 39 049 8997911Fax + 39 049 774727email [email protected] [email protected]
Date Notes
Notes and purchase details
Contact
Technical information:
![Page 12: Panels and thermo insulation systems - STIFERITE...Insulation used to eliminate “Thermal Bridges” Panel is also available upon request and only in thicknesses of 80mm-200mm for](https://reader034.fdocuments.in/reader034/viewer/2022050101/5f401f3e21c4805b221f99fe/html5/thumbnails/12.jpg)
stud
ioem
me
VI -
01.
14 -
300
- G.V
.
Stiferite Srl Viale della Navigazione Interna, 54 - 35129 Padova, ItalyTel. +39 049 8997911 - Fax +39 049 774727 email: [email protected] [email protected]
Download Stiferite’s APPAvailabe in Iphone, Ipad e Android versions