12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT PUMPER NFPA COMPLIANT Workorder: V893 Meter Reading: Close Date: In Date: 12/13/2005 12/14/2005 DOOR LATCH INOP, E-25 Problem? Parts Quantity Task performed: NO PARTS USED Workorder: V1031 Meter Reading: Close Date: In Date: 12/28/2005 01/09/2006 CHECK TIRES E-25 Problem? Parts Quantity Task performed: NO PARTS USED Workorder: V1485 Meter Reading: Close Date: In Date: 02/13/2006 02/27/2006 NEED MASONARY/METELLIC BLADE FOR K-12 SAW, E-25 Problem? Parts Quantity Task performed: NO PARTS USED Workorder: V1621 Meter Reading: Close Date: In Date: 02/24/2006 03/20/2006 Remount number plate e25 Problem? Parts Quantity Task performed: NO PARTS USED

Transcript of Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm...

Page 1: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V893

Meter Reading:Close Date:

In Date: 12/13/200512/14/2005

DOOR LATCH INOP, E-25Problem?

Parts QuantityTask performed:

NO PARTS USED

Workorder: V1031

Meter Reading:Close Date:

In Date: 12/28/200501/09/2006

CHECK TIRES E-25Problem?

Parts QuantityTask performed:

NO PARTS USED

Workorder: V1485

Meter Reading:Close Date:

In Date: 02/13/200602/27/2006

NEED MASONARY/METELLIC BLADE FOR K-12 SAW, E-25Problem?

Parts QuantityTask performed:

NO PARTS USED

Workorder: V1621

Meter Reading:Close Date:

In Date: 02/24/200603/20/2006

Remount number plate e25Problem?

Parts QuantityTask performed:

NO PARTS USED

Page 2: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V1729

Meter Reading:Close Date:

In Date: 03/06/200603/20/2006

MARKER LIGHT INOP, E-25Problem?

Parts QuantityTask performed:

101156BULB 10194BULB

Workorder: V1566

Meter Reading:Close Date:

In Date: 02/21/200603/28/2006

FRONT A/C BLOWING HOT AIR, E-25Problem?

Parts QuantityTask performed:

NO PARTS USED

Workorder: V2101

Meter Reading:Close Date:

In Date: 04/05/200604/05/2006

CHECK TIRES E-34-Problem?

Parts QuantityTask performed:

NO PARTS USED

Workorder: V2130

Meter Reading:Close Date:

In Date: 04/07/200604/14/2006

PRIMER PUMP INOP, E-25Problem?

Parts QuantityTask performed:

1501-3090-00PRIMER PUMP MOTOR

Page 3: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V2379

Meter Reading:Close Date:

In Date: 04/27/200605/12/2006

B INSPECTION, E-25Problem?

Parts QuantityTask performed:

Page 4: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

See B Inspection pre-printed form 1038-1550-00VALVE CHECK HALE 1/4"" 1107796DRYER KIT AD9 -NEW 1107800VALVE CHECK AD9 117210ZE6505FILTER AIR HONDA 1180R002HURST HYD. FLUID QT 1203FFBEARING PULLEY 13320-0027CHECK VALVE 1/2 FOAMPRO 4353R023HURST HOSE W/O SWIVEL 2370001ASEAL 35066 23720BEARING WB 23782BEARING 13934044 3938160 OIL PAN C GASKET 139768315259022 GROOVED TENSIONER OLD#3936213 154-13030055-30 CIRCUIT BREAKER 254-53030055-30BX CIRCUIT BREAKER 16806970098SEAL DOOR 17460967AIR FILTER 17210-ZE2-515 HONDA 178R536078R5360M 2PK FILTER AIR COND 1800405PURGE VALVE KIT 187401RY-30T RELAY 5 PIN 12V 191368904 VALVE KIT 1 1/2 IN 191398907 VALVE KIT 3 IN AKRON 291513AMBER LENS 19440BELT 19480BELT 1A33222T2308USE KIT195020 BRAKE PADS FL80 2BPR5ESSPARK PLUG 7734 1CA8193AIR FILTER 46744 WIX 1FS1022FILTER FUEL WIX 33422 PS8689 FRAM 2HM212011BEARING WB 2HM212049BEARING FW 4HP-31DBATTERY 950CCA HP-31D 1HPH6349AOIL FILTER 51748 2HU024AHUB COVER 1K080716BELT 1PR338324070 WIX FILTER WATER 2R002298LOCKING WASHER 1R90PFILTER FUEL 33231 1S1145REGULATOR MINI HVY DUTY 1VML-S1414FILTER P/S 1VML-T1264GASKET P/S COVER 1VML-T1279WASHER P/S

Vendor?: CENT0002

Page 5: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V3035

Meter Reading:Close Date:

In Date: 06/18/200606/23/2006

Compartment open indicator remains active. All doors and accessories checked several times without relief.Problem?

Parts QuantityTask performed:

252-624SWITCH DOOR 391823SWITCH SWT5499 MED MASTER

Workorder: V3283

Meter Reading:Close Date:

In Date: 07/05/200607/14/2006

K-12 saw leaking gas e25Problem?

Parts QuantityTask performed:

NO PARTS USED

Workorder: V3392

Meter Reading:Close Date:

In Date: 07/10/200607/17/2006

repair k650 saw E25 (outside service- regan's small engine service)Problem?

Parts QuantityTask performed:

NO PARTS USED

Vendor?: REGANS

Workorder: V4600

Meter Reading:Close Date:

In Date: 170.5009/26/200610/03/2006

Motorist ran over traffic cone. new type expandable / lighted. Cone damaged need replacement 25Problem?

Parts QuantityTask performed:

1. TRAVELED TO STN 25 TO DROP OFF NEW ROAD CONE TO REPLACE DAMAGED ONE.

NO PARTS USED

Page 6: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V5944

Meter Reading:Close Date:

In Date: 311.4012/24/200601/08/2007

wig wags do not work RE25Problem?

Parts QuantityTask performed:

1. Replaced fuse for wig wags ok NO PARTS USED

Workorder: V6169

Meter Reading:Close Date:

In Date: 43,365.0001/09/200701/17/2007

Repair fuel system E25 Cummins Power SouthProblem?

Parts QuantityTask performed:

Repair fuel system E25 Cummins Power South NO PARTS USED

Vendor?: CUMMINS POWER SOUTH

Workorder: V6742

Meter Reading:Close Date:

In Date: 412.1002/13/200702/21/2007

Front passenger seat needs repair or replacement. Spring is poking thru seat. E25Problem?

Parts QuantityTask performed:

1. TRAVELED TO STN 25. CHECKED SEAT, WILL REPAIR DURING UPCOMING PM B INSPECTION.

NO PARTS USED

Workorder: V7246

Meter Reading:Close Date:

In Date: 470.9003/17/200703/21/2007

E25 MEDICAL COMPARTMET LEAKING WATER WHEN IT RAINS. LEAK IS LOCATED AT THE TOP WHERE THE CABNET ATTACHES TO THE BODY

Problem?

Parts QuantityTask performed:

Drive to station. Tightened screws and sealed compartment

NO PARTS USED

Page 7: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V7294

Meter Reading:Close Date:

In Date: 478.7003/20/200703/23/2007

A BUZZING SOUND COMES FROM RADIO WHEN ENGINE IS RUNNING. ALSO SPEEDS UP UP WHEN RPM GOES UP. POSSIBLY A BAD ALTERNATOR. e25

Problem?

Parts QuantityTask performed:

1. Drive to station. Installed new alt., belts, and idler pulley bearing2. Officer side seat bad. Drover to site of spare truck and swapped seat from spare to E25

1203FFBEARING PULLEY 14867JB320 UPGRADE ALTERNATOR 19440BELT 19480BELT 1K080716BELT

Page 8: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V7487

Meter Reading:Close Date:

In Date: 45,068.0004/02/200704/10/2007

B INSPECTION AND REPAIRS AS NEEDED E25Problem?

Parts QuantityTask performed:

1. B Inspection2. Go to airport to copy ss card #3. Service t-case4. Service trans5. Service cooling system6. Service air dryer7. Replaced batteries and jumper connectors8. R&R officers seat for repair9. Replaced screens for intake relief valve10. Installed 2 intake screens11. Replaced rear axle brakes and pin kits. Greased and purged calipers12. Serviced generator13. Rebuilt primer valve14. Serviced Hurst tools15. Drill new holes and remount shelf rail for Hurst tools16. Replaced door seals17. Replaced door moldings18. Replaced relay for left door alarms19. Replaced check valve for intake relief valve

20100080010STRAINER 1038-1550-00VALVE CHECK HALE 1/4"" 20769027STRAINER 2.5 IN 1107796DRYER KIT AD9 -NEW 1107800VALVE CHECK AD9 215016KIT15016 PIN KIT 117210ZE6505FILTER AIR HONDA 129526898 29548988 TRANS FILTER ALLISON 23530033USE 353R222 HOSE HURST SWIVEL/ORING 13911638PLUG OIL DRAIN C 13920773WASHER DRAIN PLUG 252-24WIPER BLADES ANCO 24 26256RJN6256RJN NUT-OUTER/RIGHT 26806970098SEAL DOOR 17460967AIR FILTER 17210-ZE2-515 HONDA 178R536078R5360M 2PK FILTER AIR COND 1800405PURGE VALVE KIT 2A-1779-WGREASE ROCKWELL A-1779-W-283 1A0631087000CABLE BATT. POS. 1A0631088000CABLE BATT. NEG. 2A1834388003MOLD R/H 4BATTERY EPA TAXBATTERY EPA TAX $1.50 PER BATTERY 2BPR5ESSPARK PLUG 7734 1CA8193AIR FILTER 46744 WIX 1FS1022FILTER FUEL WIX 33422 PS8689 FRAM 2H1422TSX STUD 4HP-31DBATTERY 950CCA HP-31D 1HPH6349AOIL FILTER 51748 1PR338324070 WIX FILTER WATER 1PVG-KITORING KIT 1R90PFILTER FUEL 33231 2S2R7017173USE KIT15625PM BRAKE PAD

Page 9: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V7534

Meter Reading:Close Date:

In Date: 45,068.0004/04/200704/12/2007

REPAIR SEAT CENTRAL AUTO TRIM E25Problem?

Parts QuantityTask performed:

Repair seat Central Auto Trim e25 NO PARTS USED

Vendor?: CENTRAL AUTO TRIM

Workorder: V8843

Meter Reading:Close Date:

In Date: 46,442.0006/14/200706/29/2007

tailboard lights out E25Problem?

Parts QuantityTask performed:

1. Drive to sta. R/R tail light 101046301700S30HACP STROBE CLEAR 335200-RLIGHT MARKER LED RED

Workorder: V9052

Meter Reading:Close Date:

In Date: 46,621.0006/28/200707/03/2007

repair led lights e25Problem?

Parts QuantityTask performed:

1. DROVE TO STATION. REPLACE BOTH L.E.D. LIGHTS UNDER DOOR.

140R00FCR400 SER CLEARANCE LITE

Workorder: V9255

Meter Reading:Close Date:

In Date: 46,800.0007/10/200707/16/2007

belt and pulley damaged E25Problem?

Parts QuantityTask performed:

1. BELT AND PULLEY DAMAGED/ ROAD CALL TO PALMS WEST. CALLED & WAITED ON TOW TRUCK. SWAPPED INTO BATTALION SPARE.2. INSTALL NEW PULLEY DAMPER & FAN BEARING. ASSY/ INSTALLED NEW PARTS AT STATION.

13925570VIB DAMPNER C ENGINE 13926855FAN PULLEY 13942896FAN SUPPORT ISL 1K080716BELT 2UMVS-0811-11STRAP ZICO

Page 10: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V9254

Meter Reading:Close Date:

In Date: 46,800.0007/10/200707/17/2007

tow from 13005 Southern Blvd to shop (outside agency-sister's towing)Problem?

Parts QuantityTask performed:

Tow from 13005 Southern Blvd to shop - Sister's Towing NO PARTS USED

Vendor?: SISTERS TOW

Workorder: V9832

Meter Reading:Close Date:

In Date: 699.7008/11/200708/30/2007

front bumper water intake screen is missinng. need a new screen. thanks harold E25Problem?

Parts QuantityTask performed:

1. Drive to stn; 5" screen only; had 6" on truck2. Drive to stn; R/R frnt intake screen

2010-0020-00STRAINER

Workorder: V10098

Meter Reading:Close Date:

In Date: 714.7008/23/200709/12/2007

replace front tires at sta 25 e25 callaghan entProblem?

Parts QuantityTask performed:

Replace front tires - Callaghan NO PARTS USED

Vendor?: CALLAGHAN

Workorder: V10349

Meter Reading:Close Date:

In Date: 745.3009/10/200709/20/2007

warning light on side of hood (Lt.side next to air horn) is 10/7 needs to be replaced thanks Harold e25Problem?

Parts QuantityTask performed:

Drive to Stn; R/R ligjht - test ok 102036317300STROBE LINEAR REFLECTOR 6ELTUBE

Page 11: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V10199

Meter Reading:Close Date:

In Date: 47,935.0008/31/200709/28/2007

replace tires at sta 25Problem?

Parts QuantityTask performed:

REPLACE TIRES AT STATION 25 NO PARTS USED

Vendor?: CALLAGHAN TIRE

Workorder: V10939

Meter Reading:Close Date:

In Date: 788.8010/10/200710/24/2007

cab door handle inside cab behind driver is broken needs to be replaced or repaired thanks harold E-25Problem?

Parts QuantityTask performed:

1. drive to station. r/r handle. test ok. 16807200575HANDLE DOOR

Workorder: V11158

Meter Reading:Close Date:

In Date: 48,910.0010/22/200711/05/2007

repair broken pulley and belts e25Problem?

Parts QuantityTask performed:

diss frnt of motor to dia problem with broken pulley & hole in timing cover.

12095-7PULLEY 13926855FAN PULLEY 13943813TIMING COVER 14025270FRONT CRANK SEAL 19440BELT 19480BELT 1FREIGHTSHIPPING CHARGES 1K080716BELT

Page 12: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V11161

Meter Reading:Close Date:

In Date: 48,910.0010/22/200711/13/2007

tow unit from cleary rd to shop e25Problem?

Parts QuantityTask performed:

tow unit from cleary rd to shop e25 NO PARTS USED

Vendor?: SISTERS TOWING

Workorder: V11364

Meter Reading:Close Date:

In Date: 49,033.0011/01/200711/21/2007

REPAIR DRAIN AND REMOUNT PLACKARD E25Problem?

Parts QuantityTask performed:

Drive to stn; installed packard & installed covers on drain. j

NO PARTS USED

Workorder: V11427

Meter Reading:Close Date:

In Date: 49,096.0011/04/200711/21/2007

Spot light is burned out. E25Problem?

Parts QuantityTask performed:

Drive to stn; replc spotlight mnted on roof j

1322502BULB PATIENT GH22 1620122SPOT LIGHT REMOTE 1H6054USE CV TYPE SEALED BEAM

Workorder: V11748

Meter Reading:Close Date:

In Date: 869.4011/26/200711/30/2007

2 of the 3 step lights on the passengerside running board are not working E25Problem?

Parts QuantityTask performed:

Drive to stn; bad grnd on one; R/R bulb j NO PARTS USED

Page 13: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V11157

Meter Reading:Close Date:

In Date: 48,910.0010/22/200701/15/2008

fan pulley broken on call e25Problem?

Parts QuantityTask performed:

NO PARTS USED

Workorder: V12612

Meter Reading:Close Date:

In Date: 50,621.0001/15/200801/28/2008

replace front tires at shop e25Problem?

Parts QuantityTask performed:

Replace front tires at shop E25 - Callaghan j NO PARTS USED

Vendor?: CALLAGHAN

Workorder: V12574

Meter Reading:Close Date:

In Date: 50,621.0001/14/200801/31/2008

b inspection and repairs as needed e25Problem?

Parts QuantityTask performed:

1. B-Inspection Costner/Vasko2. Adjust rear brakes3. Pressure check/tighten clamps on rear heater & pump cooler j

105-17223-000CAP RADIATOR 10 LB 2115W40BSYN OIL BULK QTS 1FS1022FILTER FUEL WIX 33422 PS8689 FRAM 1HPH6349AOIL FILTER 51748 1R90PFILTER FUEL 33231

Workorder: V12762

Meter Reading:Close Date:

In Date: 974.3001/23/200802/06/2008

cigarette lighter/accessory 12 volt not powered r25Problem?

Parts QuantityTask performed:

1. Drive to Station, installed cig lighter for GPS, test OK. 156415CIG. LIGHTER ACCES.

Page 14: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V2060

Meter Reading:Close Date:

In Date: 03/31/200602/07/2008

DRIVER DOOR WHITE LIGHT INOP, E-25Problem?

Parts QuantityTask performed:

10106837849C8COMP LIGHT WHITE LED 200

Workorder: V13199

Meter Reading:Close Date:

In Date: 1,009.4002/12/200802/15/2008

LDH supply line leaking from pin holes around coupling E-25Problem?

Parts QuantityTask performed:

1. Drive to station, replace line. NO PARTS USED

Workorder: V13245

Meter Reading:Close Date:

In Date: 51,199.6002/14/200802/15/2008

deliver oil to sta 25Problem?

Parts QuantityTask performed:

1. Drive to station, drop off oil. 1215W40QSYN OIL QT

Workorder: V13285

Meter Reading:Close Date:

In Date: 51,199.0002/15/200802/25/2008

install 6" steamer on front suction e25Problem?

Parts QuantityTask performed:

1. Drive to station, installed 6" suction on front of truck, check for leaks, test OK

20714025GASKET 4.5 IN 1A3752MC4 X 6 ADAPTER FRONT BUMPER

Page 15: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V14023

Meter Reading:Close Date:

In Date: 1,087.5003/20/200803/24/2008

air brakes losing alot of air when brakes are applied. making a normal stop low air alarm comes on. e25Problem?

Parts QuantityTask performed:

1. found air leak at front line air hose. take one off spare eng. installed and tested.2. replace both front line and spare.

4A2312249023FRONT BRAKE HOSE

Workorder: V14162

Meter Reading:Close Date:

In Date: 1,107.1003/29/200804/03/2008

officers side rear fixed scene light is 10/7 e25Problem?

Parts QuantityTask performed:

1. Drive to station, found rip lens off screws stripped out, temporarlly installed2. Drive to station with new lens. Drill out screws and installed new lens, test OK

252-24WIPER BLADES ANCO 24 2681181363356811813633S LENS CLEAR 1H50SN12BULB

Workorder: V14627

Meter Reading:Close Date:

In Date: 1,146.0004/22/200805/30/2008

ALARM GOING OFF INTERMITENTLY IN TRUCK. SOUNDS LIKE A LOW AIR ALARM, ALL GUAGES ARE READING NORMAL. r25

Problem?

Parts QuantityTask performed:

1. Drive to stn; take dash apart; replc parking brake; disconnect; low volt arlm.2. Drive to stn; installed load manager in compart; short in door & step light; look for short; send to shop.3. Electrical - Murray 4/23/08 4.0 hrs 4/24/08 7.0 hrs Total 11.0 hrs4. Electrical - Hines 4/23/08 4.0 hrs 4/24/08 4.0 hrs Total 8.0 hrs5. Install/rewire new connector; reinstall electrical panel.6. Resecure all wires/electrical panel; replc pin switches for compartment doors. j

1101540TSM CIRCUIT BOARD SPEC OPS AND QUINTS 41156BULB 133000018219 PIN PLUG DEUTCH 752-624SWITCH DOOR 154-13030055-30 CIRCUIT BREAKER 154-140CIRCUIT BREAK 40 AMP 462201BACK-UPLIGHT 2ACX-84534LUG NUT COVER PK10 2DPSTDPST SW-ROCKER 1FREIGHTSHIPPING CHARGES 1FSC17492134NC SW PARK BK SPADE TYPE CONNECTOR

Page 16: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V15135

Meter Reading:Close Date:

In Date: 1,168.5005/16/200806/09/2008

TRUCK NOT MAINTAINING AIR PRESSURE SE AT 25Problem?

Parts QuantityTask performed:

Drive to Stn; replc gov & fitting; replc fitting for air tank; test ok. j

212105QUICK DRAIN 1VHD18537USE 284358 AIR GOVERNOR D-2 KN18537

Workorder: V15046

Meter Reading:Close Date:

In Date: 1,163.2005/13/200806/10/2008

engine 25 cab door lights and step lights turning off & on possible short. also other lights not working properly on E25 need to be checked. thanks harold

Problem?

Parts QuantityTask performed:

5-13 Traced & repaired step & door light issue; found bulbs to hot and found bad breaker; found and replaced broken switch for door ajar alarm5-13 Murray assisted5-13 Hines assisted

101141BULB 1120257100C2030-7110-30 CLEAR DOME STEP 1361000005RELAY FERRARA/EONE 1516594MINI 20 AMP CB211-20 CIRCUIT BREAKER 152-624SWITCH DOOR 16805400445SWITCH HEADLIGHT

Workorder: V15482

Meter Reading:Close Date:

In Date: 53,286.0006/02/200806/16/2008

Intermittant problem. When putting pump in gear, it goes into 5th gear, pump engage light comes on but ok to pump light doesn't come on. Putting it into reverse for several feet seems to correct the problem. E25

Problem?

Parts QuantityTask performed:

1. Solder board in ____ & panel.2. Drive to Stn; fnd board had loose connection; send to shop for Carl. j

NO PARTS USED

Page 17: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V15116

Meter Reading:Close Date:

In Date: 52,776.0005/15/200806/17/2008

no pump throttle e25Problem?

Parts QuantityTask performed:

1. drive to station transfer case switch open case and replaced switch. test ok air leak at parking brake replaced test ok.

1200-2450-00NC SWITCH OK TO PUMP 1800034VALVE PARKING BRK.

Workorder: V15559

Meter Reading:Close Date:

In Date: 53,399.0006/05/200807/01/2008

repair hurst unit e25Problem?

Parts QuantityTask performed:

1. drive to station. r/r plug and cleaned carb test = ok NO PARTS USED

Workorder: V15854

Meter Reading:Close Date:

In Date: 1,246.2006/19/200807/07/2008

Front passenger door does'nt latch properly e25Problem?

Parts QuantityTask performed:

1. drive to station installed new latch and adjusted test=ok

118-29935-001RH DOOR LATCH NEW

Workorder: V15819

Meter Reading:Close Date:

In Date: 1,246.2006/18/200807/08/2008

right side discharge work lights have one bulb that is burned out needs to be replaced. thanks harold 25Problem?

Parts QuantityTask performed:

1. drive to station bolts strip out cut screws installed new lights 2. drive to station screws strip installed new lens and bulb

NO PARTS USED

Page 18: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V16185

Meter Reading:Close Date:

In Date: 54,048.0007/07/200807/21/2008

ON CALL WHEEL SEAL LEAKING E25Problem?

Parts QuantityTask performed:

Went to station for smoking brakes; fnd R-rear wheel seal leak; took drive to shop for a spare truck. j

NO PARTS USED

Page 19: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V16220

Meter Reading:Close Date:

In Date: 54,048.0007/08/200807/21/2008

c inspection and repairs as needed e25 Grease seal leakingProblem?

Parts QuantityTask performed:

1. C-inspection2. C-Inspection3. Fork lift training4. C-Inspection5. R/R rear brakes, seals & rotor, pads.6. R/R rear brakes, seals, studes, rotors & pads.7. Replc inlet relief chk valve; #1 discharge valve, #2 discharge valve, #4 discharge valve.8. Training all day.9. R/R master intake relief valve.10. Adj master intake relief valve.11. Adj rear brakes. j

1038-1550-00VALVE CHECK HALE 1/4"" 1107796DRYER KIT AD9 -NEW 1107800VALVE CHECK AD9 21280008CONNECTOR SET 2415W40BSYN OIL BULK QTS 1180R002HURST HYD. FLUID QT 21893BULB 1200-0540-03200-0540-15-0 LIGHT YELLOW/HALE 1200054000USE 2000540080 LIGHT ASSY GREEN 2020X2136STUD 23218K167ROTOR-BRAKE 833700243370024 O-RING 135200-RLIGHT MARKER LED RED 2380003ASEAL 2401581GASKET AXLE FL80 R002435 1546-1620-02MASTER INTAKE KIT 46256RJN6256RJN NUT-OUTER/RIGHT 16806970098SEAL DOOR 1800405PURGE VALVE KIT 391388906 VALVE KIT 2.5 IN AKRON 19440BELT 19447BELT 19480BELT 1CA8193AIR FILTER 46744 WIX 20E-600013-3052 NUT 1FS1022FILTER FUEL WIX 33422 PS8689 FRAM 4H1422TSX STUD 1HPH6349AOIL FILTER 51748 1K080716BELT 1N251FN252F NEW # FRONT COVERS ENGINE 20R004961ANUT ROTOR/HUB 1R90PFILTER FUEL 33231 1RD571290 01-2616 MOTOR 12V 73R-0542 3512 2S2R7017173USE KIT15625PM BRAKE PAD 1VML-S1414FILTER P/S 1VML-T1264GASKET P/S COVER 1VML-T1279WASHER P/S

Page 20: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V16770

Meter Reading:Close Date:

In Date: 54,341.0008/01/200808/01/2008

assemble 4 new chain saws per BC BakerProblem?

Parts QuantityTask performed:

Assemb;e (4) chain saws. j NO PARTS USED

Workorder: V16779

Meter Reading:Close Date:

In Date: 1,311.4008/02/200808/07/2008

AIR CONDITIONER NOT COMING ON ALL THE TIME WHEN YOU TURN IT ON.IT EVENTUALLY COMES ON. E-25Problem?

Parts QuantityTask performed:

1. drive to station , installed switch test ok 1ABPN8332229011-3050 SWITCH BLOWER

Workorder: V16851

Meter Reading:Close Date:

In Date: 1,311.4008/05/200808/08/2008

driver side rear tail board red led warning light is 10/7. passenger side yellow marker light is 10/7 E-25Problem?

Parts QuantityTask performed:

R/R lights; test ok. j NO PARTS USED

Workorder: V16783

Meter Reading:Close Date:

In Date: 54,341.0008/02/200808/11/2008

passenger outside step light on right side out. E-25Problem?

Parts QuantityTask performed:

1. drive to station installed bulb test ok NO PARTS USED

Page 21: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V17288

Meter Reading:Close Date:

In Date: 54,844.1008/25/200808/25/2008

ON CALL E25 ROTATOR LT OUTProblem?

Parts QuantityTask performed:

1. drive to st. 25 replace bulb for L / R rotator 1H35SN12BULB

Workorder: V16852

Meter Reading:Close Date:

In Date: 1,311.4008/05/200808/28/2008

engine 25 air brake system leaking airProblem?

Parts QuantityTask performed:

Chk for leaks; R/R (2) fittings at foot valve. j 160R00FRR600 SERIES RED LED W/O FLANGE

Workorder: V17469

Meter Reading:Close Date:

In Date: 55,107.4009/02/200809/29/2008

air flat tire e25Problem?

Parts QuantityTask performed:

Air flat tire E25 - Callaghan j NO PARTS USED

Vendor?: CALLAGHAN

Workorder: V17834

Meter Reading:Close Date:

In Date: 1,406.6009/20/200809/29/2008

scene light located on the LT side of the engine is not working properly E-25Problem?

Parts QuantityTask performed:

TRAVEL TO STA REPLCE WIRES ON SCENE LTS NO PARTS USED

Page 22: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V18095

Meter Reading:Close Date:

In Date: 1,434.0010/02/200810/09/2008

need exhaust clamp for exhaust leak on e25Problem?

Parts QuantityTask performed:

1. drive to Sta. Installed clamp found bolt broken in exhaust, talk to Ed about.

(R.T.)

1115774CLAMP V-BAND 12500902250-0902 CLAMP EXHAUST

Workorder: V18368

Meter Reading:Close Date:

In Date: 56,061.3010/16/200810/20/2008

repair broken bolt and gasket on exhaust manifold e25Problem?

Parts QuantityTask performed:

drilled/rem #1 bottom exh manifold broken bolt; had to loosen exh manifold to replace gasket; replc gasket, bolt & spacer; tighteened exh flange clamp; tightened batry term. j

13088579SPACER EXH BOLT 639374795269779 EXHAUST GASKET C 23944593EXH. MAN. BOLT

Workorder: V18388

Meter Reading:Close Date:

In Date: 1,461.3010/17/200810/20/2008

Left front turn signal bulb is out, E-25Problem?

Parts QuantityTask performed:

Meeting at shop w/upper staff & drive to Stn; 25 & R/R bulb turn signal; test ok. j

NO PARTS USED

Workorder: V18292

Meter Reading:Close Date:

In Date: 1,444.0010/11/200810/21/2008

Lt's sun visor keeps falling down when in the up(standby) position. E-25Problem?

Parts QuantityTask performed:

Drive to Stn; replc sunvisor; test ok. j 11836267000VISOR RETRN

Page 23: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V18322

Meter Reading:Close Date:

In Date: 55,896.0010/14/200810/24/2008

on call e25 water leak at pump panelProblem?

Parts QuantityTask performed:

Water leak @ pump panel; hose to test port snagged & fitting @ relief valve defective; rep line & installed new fitting. j

NO PARTS USED

Workorder: V18825

Meter Reading:Close Date:

In Date: 1,492.2011/03/200811/17/2008

driver side rear red marker light 10/7 E-25Problem?

Parts QuantityTask performed:

Drive to Stn; installed marker ight; test ok. j 235200-RLIGHT MARKER LED RED

Workorder: V19089

Meter Reading:Close Date:

In Date: 1,511.8011/15/200811/20/2008

driver side of hood red warning light is 10/7 needs to be replaced. thanks harold E-25Problem?

Parts QuantityTask performed:

Drive to Stn; replcd light; test ok. j 102036317300STROBE LINEAR REFLECTOR 6ELTUBE 14626BPMR7A SPARK PLUG

Workorder: V19307

Meter Reading:Close Date:

In Date: 1,528.3011/24/200812/17/2008

E25 rear tailboard step lights are 10/7 possibly a bad switch. thanks haroldProblem?

Parts QuantityTask performed:

1. Go Stn25; unit not there.2. Fnd short at rear steps; rep; test ok. j

NO PARTS USED

Page 24: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V19407

Meter Reading:Close Date:

In Date: 56,985.7012/01/200812/17/2008

cut sign to fit E25Problem?

Parts QuantityTask performed:

1. Cut signs to fit holders.2. Drive to Stn; installed signs. j

NO PARTS USED

Workorder: V19842

Meter Reading:Close Date:

In Date: 57,435.9012/18/200812/31/2008

CHECK REAR BRAKES, E-25Problem?

Parts QuantityTask performed:

1. Drive to Stn; chk bnrakes; fnd quick release slow; order valve.\2. Drive to Stn; installed valve for quick release; drive; ok; driver talked about air leak; will return tomorrow.3. Drive to Stn; isntalled valve fitting on foot valve; chk for leaks; test ok. j

1065066802745 VALVE QUICK REL.

Workorder: V19918

Meter Reading:Close Date:

In Date: 12/22/200812/31/2008

gas power fan rubber boots brokenx4 e25Problem?

Parts QuantityTask performed:

Drive to Stn; replace feet on fan; test ok; j 7FZ51368FEET RUBBER RAM-FAN

Workorder: V19641

Meter Reading:Close Date:

In Date: 1,561.3012/09/200801/02/2009

E25 2 1/2 inch discharge & intake cap chains & connectors need to be repaired. thanks harold P.S. Happy holidays From the B-shift crew

Problem?

Parts QuantityTask performed:

Replaced (6) chains to truck & cap; test ok. j 8108-12FBEADED CHAIN W/CONN 12

Page 25: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V19917

Meter Reading:Close Date:

In Date: 57,435.9012/22/200801/15/2009

REPLACE 4 REAR TIRES, E-25Problem?

Parts QuantityTask performed:

NO PARTS USED

Vendor?: CALLAGHAN

Workorder: V20004

Meter Reading:Close Date:

In Date: 1,603.2012/29/200802/04/2009

rear step lights out E25Problem?

Parts QuantityTask performed:

1- Drive to station, check power at stw good follow wire to class one boald good bad wire going to lights.2- Drive to station, follow wires on frame found cut wire replaced wires test ok.

NO PARTS USED

Workorder: V20470

Meter Reading:Close Date:

In Date: 1,655.0001/20/200902/04/2009

medical compartment door light switch is 10/7 needs to be replaced thanks Harold E-25Problem?

Parts QuantityTask performed:

1- Drive to station, wareing bad rewire stw in door and replaced stw test ok.

152-624SWITCH DOOR

Workorder: V20933

Meter Reading:Close Date:

In Date: 58,713.7002/06/200902/23/2009

tic needs a retractable lanyard to clip on carribeaner E25Problem?

Parts QuantityTask performed:

replc lanyard; test ok. j NO PARTS USED

Page 26: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V21129

Meter Reading:Close Date:

In Date: 1,716.0002/16/200902/24/2009

needed oil for all sta.25 trucks. caught mike and he gave me a case of oil . please replace the case he gave me for sta.25 thanks harold.

Problem?

Parts QuantityTask performed:

drop off oil (1) case. j 1215W40QSYN OIL QT

Workorder: V18070

Meter Reading:Close Date:

In Date: 1,434.0010/01/200803/02/2009

engine 25 has an exhaust leak up by the exhaust manifoldProblem?

Parts QuantityTask performed:

NO PARTS USED

Workorder: V22042

Meter Reading:Close Date:

In Date: 1,791.3003/24/200904/08/2009

red marker light 10/7 on e-25 driver side rear. thanks haroldProblem?

Parts QuantityTask performed:

Drive to Stn; screws stripped out; tap & rewire marker lite; test ok. j

NO PARTS USED

Workorder: V22283

Meter Reading:Close Date:

In Date: 1,802.9004/02/200904/17/2009

E25 TIC CHARGER HAS A BROKEN CHARGING PIN FOR THE UNITS SPARE BATTERY. IT NEEDS TO BE FIXED IF POSSIBLE BECAUSE SPARE BATTERY WILL NOT CHARGE. THANKS HAROLD

Problem?

Parts QuantityTask performed:

Drive to Stn; replcd TIC charger; test ok. j NO PARTS USED

Page 27: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V22520

Meter Reading:Close Date:

In Date: 59,850.5004/13/200904/27/2009

B INSPECTION AND REPAIRS AS NEEDED E25Problem?

Parts QuantityTask performed:

B-Inspection2. Rem water filter hsng; replcd faulty cutoff valve.3. Svc coolant.4. Assisted w/trying to get the blue lift down.5. Rep faulty spotlight on roof of cab.6. Right side turn signal out; fnd & repcld faulty multi-function swtch.7. Replcd 9/11 decals on rear of body.8. Installed hose bed cover. 9. Rem trans retarder & rebuild; cln trans/retarder; reassemble.10. Fnd plug on side of trans leaking; drained fluid; clnd area/replcd plug.11. T-shoot horn inop;12. Coolant leaking filter head; replcd filter head.13. Lubed valves to ease opn; fnd linkage binding up; rep linkage.14. Final chk of rep & test drive to make sure rebuilt retarder functions properly; topped off trans fluid. j

12950782329546229 SEAL FILL TUBE 12953032829530328 PLUG OIL FILL TU 129535973ACCUM.KIT 23818885O-RING WATER SHUT OFF 13937367GASKET 4942874 139437384940575 HEAD CORROSION RESISTER 139437394940547 SHAFT SHUT-OFF VALVE 13943740SHAFT SHUT-OFF VALVE 139438574989614 SEAL O-RING SHUT-OFF VALVE 139444543977737 SCREW SHUTOFF VALVE 1620122SPOT LIGHT REMOTE 1680-10LAMERICAN FLAG W UV CLEAR LEFT 1680-10RAMERICAN FLAG W UV CLEAR RIGHT 16805450124SWITCH TURN SIGNAL 1A0631117000HORN HIGH NEW # 06-52125-039 1A0631117003HORN LOW NEW #06-52125-041 1FS1022FILTER FUEL WIX 33422 PS8689 FRAM 1H3-100WBP1210H3 BULB 1HPH6349AOIL FILTER 51748 1PR338324070 WIX FILTER WATER 1R90PFILTER FUEL 33231

Workorder: V22804

Meter Reading:Close Date:

In Date: 1,836.0004/26/200905/04/2009

air brakes have a bad leak. top guage reads 120 psi and drops to 110 psi after 2hrs. bottom guage reads 120 psi and drops to 50 psi after 2hrs E-25

Problem?

Parts QuantityTask performed:

1. Drive to Stn; replc (2) fitting on air tank; replcd fitting on retracter valve; replc fitting on foot valve; need kit for pump shift.2. Drive to Stn; rebuild air pump shift; test ok. j

1037-1341-50-0VPS SHIFT KIT 2 PIECE 312105QUICK DRAIN

Page 28: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V22805

Meter Reading:Close Date:

In Date: 1,836.0004/26/200905/04/2009

e25 turn signal switch not working properly. it does not return to the off position after making a left hand turn.Problem?

Parts QuantityTask performed:

Drive to Stn; installed turn signal swtch; test drive; ok. j

16805450124SWITCH TURN SIGNAL

Workorder: V22547

Meter Reading:Close Date:

In Date: 59,850.5004/14/200905/11/2009

repair hose bed cover e25 centralProblem?

Parts QuantityTask performed:

Repair hose bed cover E25 - Central Auto j NO PARTS USED

Vendor?: CENTRAL AUTO TRIM

Workorder: V22986

Meter Reading:Close Date:

In Date: 1,847.8005/02/200905/14/2009

E-25 primer is bad. Contacted on call mechanic who responded to station 25 and replaced unit. Primer is now working properly. Thanks Harold

Problem?

Parts QuantityTask performed:

Replace primer pump on eng. j 1501-3090-00PRIMER PUMP MOTOR

Workorder: V23660

Meter Reading:Close Date:

In Date: 1,886.4005/29/200906/02/2009

mobile radio on e25 is not working properlyProblem?

Parts QuantityTask performed:

contacted steven lee 6/1 NO PARTS USED

Page 29: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V23556

Meter Reading:Close Date:

In Date: 1,879.9005/26/200906/15/2009

E-25 has a front grill red warning light that is 10/7 possibly a bad bulb. Thanks HaroldProblem?

Parts QuantityTask performed:

Drive to Stn; replcd light; test ok. j 102036317300STROBE LINEAR REFLECTOR 6ELTUBE 1SPK122SPEAKER RESCUE BUMPER WING

Workorder: V23467

Meter Reading:Close Date:

In Date: 1,875.3005/21/200906/23/2009

electrical short in turn signals/4way flasher E-25Problem?

Parts QuantityTask performed:

Drive to Stn; trace wires - bad grand on turn signal; rep test ok. j

1372000030BATTERY ON DISPLAY 24482044820 FLASHER 16805450124SWITCH TURN SIGNAL 2EL12FLASHER ELECTRONIC

Workorder: V23557

Meter Reading:Close Date:

In Date: 1,879.9005/26/200906/23/2009

E-25 lower marker lights 10/7. Thanks HaroldProblem?

Parts QuantityTask performed:

Drive to Stn; replc (3) marker light; test ok. j 335200-RLIGHT MARKER LED RED

Workorder: V23802

Meter Reading:Close Date:

In Date: 1,895.1006/03/200906/23/2009

CONDENSOR FAN FOR AC IS MAKING NOISE. e25Problem?

Parts QuantityTask performed:

drive to Stn; replc both condensor fan; test ok. j 2RD-5-7123-0 18-2108 FIVE BLADE FAN 3382 2RD571290 01-2616 MOTOR 12V 73R-0542 3512

Page 30: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V24739

Meter Reading:Close Date:

In Date: 1,972.0007/13/200907/22/2009

E-25 has a small oil leak at one of the oil filters possibly a bad gasket. Thanks HaroldProblem?

Parts QuantityTask performed:

Drive to Stn; tighten filter; test ok. j NO PARTS USED

Workorder: V24740

Meter Reading:Close Date:

In Date: 1,972.0007/13/200907/22/2009

E-25 roof warning light bar has a bulb that is 10/7 needs to be replaced. Thanks HaroldProblem?

Parts QuantityTask performed:

drive to Stn; replcd bulbs; test ok. j 202034036200CLIGHT ASSY STROBE 27ELTUBE7ELTUBE LINEAR STROBE REF

Workorder: V25543

Meter Reading:Close Date:

In Date: 2,033.5008/15/200908/17/2009

E25 LIGHT BAR ON TOP OF CAB HAS WARNING LIGHT THAT IS BAD ON THE DRIVERS SIDE.Problem?

Parts QuantityTask performed:

Rep faulty strobelight. j NO PARTS USED

Workorder: V25544

Meter Reading:Close Date:

In Date: 2,033.5008/15/200908/20/2009

E25 YELLOW MARKER LIGHT ON DRIVERS SIDE BELOW DRIVERS COMPARTMENT IS 10/7Problem?

Parts QuantityTask performed:

Drive to Stn; replcd bulb; glue light back tog; test ok. j

2322502BULB PATIENT GH22 1STOPSN12BULB STOP/TAIL LIGHT

Page 31: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V25586

Meter Reading:Close Date:

In Date: 62,046.9008/17/200908/25/2009

e25 hose bed divider needs to adjusted to allow for blitz lineProblem?

Parts QuantityTask performed:

Go to Stn25; cannot take out of svc; rep on W/O 25625. j

NO PARTS USED

Workorder: V25625

Meter Reading:Close Date:

In Date: 2,038.4008/18/200908/25/2009

E25 hose bed divider needs to be moved over do to new 21/2 blitz line configuration. Divider can be moved at rear but needs new bolt holes drilled at front of hose bed. Check with crew on positioning. Thanks Harold

Problem?

Parts QuantityTask performed:

Drive to Stn25; adj divider; drill/tap frnt holes; help load hose. j

NO PARTS USED

Workorder: V25874

Meter Reading:Close Date:

In Date: 2,054.8008/28/200909/03/2009

Receicved three Quic-straps #UMVS-2544-11 from Lehan for E25 coil pack.Problem?

Parts QuantityTask performed:

drive to Stn; drop off straps. j 3UMVS254411STRAP 46 IN

Workorder: V26075

Meter Reading:Close Date:

In Date: 445.4009/05/200909/17/2009

TRUCK CAB LEAKING AFTER A HEAVY RAIN. BEHIND THE OFFICERS SEAT FROM ROOF e25Problem?

Parts QuantityTask performed:

Drive to Stn; seal roof w/sealant. j NO PARTS USED

Page 32: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V26116

Meter Reading:Close Date:

In Date: 2,085.1009/08/200909/17/2009

Yellow marker light is 10/7 at the drivers compartment. Thanks Harold E25Problem?

Parts QuantityTask performed:

drive to Stn; rewire & replcd marker light. j 135200-YLIGHT MARKER LEDAMBER

Workorder: V26317

Meter Reading:Close Date:

In Date: 62,713.5009/16/200909/25/2009

Air leak E25 on-callProblem?

Parts QuantityTask performed:

Svc call to Stn25; ck for air leak in cab; rem dash panels; fnd swtich leaking; R/R switch; ck for leak; ck ok; reinstalled panels; return home. j

1FSC17492134NC SW PARK BK SPADE TYPE CONNECTOR

Workorder: V26113

Meter Reading:Close Date:

In Date: 2,085.1009/08/200909/30/2009

Red warning light is 10/7 on the drivers side at the step to the pump panel e25Problem?

Parts QuantityTask performed:

Drive to stn; replc light; test ok. j 160R00FRR600 SERIES RED LED W/O FLANGE

Workorder: V27627

Meter Reading:Close Date:

In Date: 2,193.4011/13/200911/23/2009

POSSIBLE AIR LEAK, HAVE TO PUMP THE ACCELERATOR IN ORDER TO ACHIEVE PROPER AIR PRESSURE E25Problem?

Parts QuantityTask performed:

Went to St25; sprayed air lines etc; R/R fitting at air tank; rep leak at horn solenoid & air compressor; ran/ck for leaks; ck ok. j

NO PARTS USED

Page 33: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V27725

Meter Reading:Close Date:

In Date: 2,200.2011/17/200911/30/2009

Engine25 still has a bad air leak in the air brake system. Needs to be fixed. Thanks HaroldProblem?

Parts QuantityTask performed:

Aired up truck; fnd fittings at air tank leaking & need replcd rem air lines/fittings; replcd fittings; ran/ck for leaks; ck ok. j

NO PARTS USED

Workorder: V28036

Meter Reading:Close Date:

In Date: 2,226.8012/01/200912/17/2009

E-25 still has a bad air leak in the braking system. Thanks HaroldProblem?

Parts QuantityTask performed:

Travel to stn; chk for leaks; small leaks only; eng was called out shortly after I arrived; waited awhile & left to another stn. j

NO PARTS USED

Workorder: V28155

Meter Reading:Close Date:

In Date: 64,153.7012/07/200912/17/2009

right low beam headlight is out e25Problem?

Parts QuantityTask performed:

1. Drive to Stn25; replc R/F headlight.2. Chk truck for air leak; fnd pump to road valve leaking; senty truck to shop. j

1H6054USE CV TYPE SEALED BEAM

Workorder: V28170

Meter Reading:Close Date:

In Date: 12/07/200912/21/2009

Air leak E25Problem?

Parts QuantityTask performed:

1. Try to find air leak; rep air leaks; retest; rep air leak under cab on dash etc.; test drive.2. Rep loose & stuck btry hardware; replc bolts falling out. j

NO PARTS USED

Page 34: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V28569

Meter Reading:Close Date:

In Date: 2,258.4012/24/200901/06/2010

b25 siren o.o.sProblem?

Parts QuantityTask performed:

See W/O 28598 j NO PARTS USED

Workorder: V28631

Meter Reading:Close Date:

In Date: 2,258.4012/22/200901/06/2010

E-25 is still leaking air. It seems to loose more air pressure when the weather is cold. Thanks Harold.Problem?

Parts QuantityTask performed:

Chkd for leaks w/soapy water; cld not see or hear any air; leak rate is in acceptacle margin; will to wait til leak is greater. j

NO PARTS USED

Workorder: V28486

Meter Reading:Close Date:

In Date: 627.6012/19/200901/08/2010

Air brake air leak at the pump engage/disengage lever. Thanks Harold E25Problem?

Parts QuantityTask performed:

Replcd VPS o-ring hit on pump shift. j 15460370530VPS SHIFT KIT 546-0370-53-0

Workorder: V28812

Meter Reading:Close Date:

In Date: 64,678.2001/05/201001/26/2010

possible air leak in breaks E25Problem?

Parts QuantityTask performed:

1. Drive to stn24; C/O truck; fnd VPS valve leaking; chk air in shift valve in cab; rep at training at 1300 hr when out of svc.2. Went to training; replc VPS seals & tighten plug for VPS plug in console of truck. j

15460370530VPS SHIFT KIT 546-0370-53-0

Page 35: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V29479

Meter Reading:Close Date:

In Date: 2,300.8001/27/201002/11/2010

E-25 is losing radiator fluid at the fill cap. Possibly a bad cap. Needs to be checked. Thanks HaroldProblem?

Parts QuantityTask performed:

1. Went to Stn25; press tested cooling sys; cld not find any leak; ck cap; ck ok.2. R/R bulb for pump overheat gauge. j

11893BULB

Page 36: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V29003

Meter Reading:Close Date:

In Date: 64,779.8001/11/201002/16/2010

C inspection and repairs as needed E25Problem?

Parts QuantityTask performed:

Page 37: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

C-Service2. Replcd all (4) btrys; also replcd pos/neg jumper cables.3. Press tested cooling sys to chk for coolant leak; fnd leak at upper rad hose clamps; tightened clamps & retested.4. Replcd air brake compressor coolant tube/line (leaking/rusted).5. Replcd (2) brkn A/C vents in dash.6. Replcd wiper blades.7. Replcd rear A/C filter.8. Replcd T/S side marker lense-cracked.9. Painted fuel cap.10. Replcd right/left intake screens.11. Replcd both rear upper bullet marker light asys.12. Replcd flag stickers on body.13. Replcd eng air filter.14. Rem old fire rescue stkrs frm both frnt cab doors & replcd w/new.15. Peeled lettering off of cab doors & replcd w/new (peeling/faded).16. Svc T-case.17. Svc air dryer.18. Replcd belts.19. Built new RPM counter cable.20. Replcd easy loc clamp on tailboard.21. Rebuilt deck gun valve.22. Rebuilt tank fill/recirc valve.23. Rebuilt vac pump valve.24. Vac test sys after above repairs; test start: 22-1/2" test end: 21".25. T-shoot foam sys inop; traced problem to debris lodged in paddle wheel flow sensor.26. Replcd foam pump w/new styles; replcd hoses/fittings; also fab cvr to keep wtr off of pump.27. C/O master intake indicator lights inop; traced problem to faulty fuse inline of the harness; replcd fuse/cln fuse holder.28. Replcd door alarm swtch in left/rear lower compt door.29. Replcd (2) door weatherstrips-ripped/torn.30. Replcd (2) door trims-brkn. j

1048009000SPEEDCOUNTER PUMP PANEL 20769027STRAINER 2.5 IN 1107796DRYER KIT AD9 -NEW 1107800VALVE CHECK AD9 31141BULB 1120257100C2030-7110-30 CLEAR DOME STEP 2415W40BSYN OIL BULK QTS 12032-0000-30LENS CLEAR 2372000082CHROME MARKER LIGHT MOUNT 2372000083GASKET MOUNTING 2372000084MARKER LIGHT 2372000085HARNESS FOR MARKER LIGHT 13944496COMPRESSOR INLET TUBE 14300-505PUMP FLOJET 12V 14435HEADLIGHT 252-24WIPER BLADES ANCO 24 152-624SWITCH DOOR 1680-10LAMERICAN FLAG W UV CLEAR LEFT 1680-10RAMERICAN FLAG W UV CLEAR RIGHT 16806970098SEAL DOOR 16808300074VENT A/C LH 16808300174VENT A/C RH 178R536078R5360M 2PK FILTER AIR COND 1800405PURGE VALVE KIT 191368904 VALVE KIT 1 1/2 IN 191398907 VALVE KIT 3 IN AKRON 291513AMBER LENS 19440BELT 19480BELT 1A0631087000CABLE BATT. POS. 1A0631088000CABLE BATT. NEG. 2A1834388003MOLD R/H 4BATTERY EPA TAXBATTERY EPA TAX $1.50 PER BATTERY 1CA8193AIR FILTER 46744 WIX 4HP-31DBATTERY 950CCA HP-31D 1HPH6349AOIL FILTER 51748 1K080716BELT 2NI PLATEMARKER LIGHT MOUNTING PLATE 1PR338324070 WIX FILTER WATER 1PVG-KITORING KIT 2S1003-A3103015 SEAL 1S448GAUGE TIRE TREAD DEPTH 1S777COUPLING NIPPLE

Page 38: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V29358

Meter Reading:Close Date:

In Date: 64,779.8001/22/201002/25/2010

HOSE BED COVER E25 CENTRALProblem?

Parts QuantityTask performed:

Hose bed cover E25 - Central Auto j NO PARTS USED

Vendor?: CENTRAL AUTO

Workorder: V29767

Meter Reading:Close Date:

In Date: 65,063.4002/06/201003/03/2010

front driver side tire is worn down to the wear bars E25Problem?

Parts QuantityTask performed:

Ck tread depth on steer tires; ck ok. j NO PARTS USED

Workorder: V30437

Meter Reading:Close Date:

In Date: 65,721.5003/04/201003/25/2010

Door handle on interior broke while exiting truck in full PPE at training E25Problem?

Parts QuantityTask performed:

1. Fnd hose off of #1 crosslya; rem fitting; replc fitting & reattached hose; ck ok. 2. Fnd officers door handle brkn on inside door panel; R/R handle; tightened all other door handles; ck ok. j

NO PARTS USED

Workorder: V28548

Meter Reading:Close Date:

In Date: 2,258.4012/22/200904/14/2010

THERMAL IMAGING UNIT HAS A GHOST ON THE DISPLAY SCREEN NEEDS TO BE REPAIRED ASAP. THANKS HAROLD ASSET# FOR THE UNIT IS 10173227

Problem?

Parts QuantityTask performed:

Drove to Stn25; swapped out TIC charger. j NO PARTS USED

Page 39: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V30965

Meter Reading:Close Date:

In Date: 65,997.3003/23/201004/20/2010

primer hose leaking water. e25Problem?

Parts QuantityTask performed:

Went to Stn25; fnd hose leaking; tightened all fittings; ran/ck ok. j

NO PARTS USED

Workorder: V31306

Meter Reading:Close Date:

In Date: 66,431.4004/06/201004/28/2010

Air leak on a capped air line in the engine compartment at the fire wall drivers side. Thanks Harold E25Problem?

Parts QuantityTask performed:

Air leak under dash on eng; C/O; fnd air leak in eng compt; replc fitting. j

NO PARTS USED

Workorder: V32050

Meter Reading:Close Date:

In Date: 66,845.7005/06/201005/24/2010

E-25 rear tailboard step lights are all 10/7Problem?

Parts QuantityTask performed:

Went to Stn25; fnd all rear step lites out; ck switch in console; ck ok; rem panel in L-1 compts; ck & t-shoot sys; R/R relay; ck opn; ck ok. j

187401RY-30T RELAY 5 PIN 12V

Workorder: V32517

Meter Reading:Close Date:

In Date: 67,358.5005/30/201006/21/2010

Drivers side front tire is down to the tread bars and needs to be replaced ASAP. THANKS HAROLD E25Problem?

Parts QuantityTask performed:

Went to HQ; ck steer tires; needs tires; called shop. j NO PARTS USED

Page 40: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V32967

Meter Reading:Close Date:

In Date: 67,691.0006/17/201006/29/2010

recip saw has a broken handle an needs to be repaired or replaced. thanks HAROLD E25Problem?

Parts QuantityTask performed:

Has been swapped. j NO PARTS USED

Workorder: V33014

Meter Reading:Close Date:

In Date: 67,740.9006/20/201006/29/2010

Exhaust on E-25 is missing a U-bolt up closest to the exhaust manifold. Needs to be fixed. Thanks HaroldProblem?

Parts QuantityTask performed:

Went to 25; fnd lower support brkt u-bolts for exh msng; ret to 25; replc/mntd u-bolt; ck ok. j

135799FLAT CLAMP 4 IN

Workorder: V32571

Meter Reading:Close Date:

In Date: 67,358.5006/01/201006/30/2010

REPALCE FRONT TIRES E25 BOULEVARDProblem?

Parts QuantityTask performed:

Replace front tires E25 - Boulevard j NO PARTS USED

Vendor?: BOULEVARD TIRE

Workorder: V30240

Meter Reading:Close Date:

In Date: 65,532.7002/25/201007/14/2010

REPAIR AIR LEAKS E25Problem?

Parts QuantityTask performed:

Verified job. j 1800034VALVE PARKING BRK.

Page 41: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V33272

Meter Reading:Close Date:

In Date: 67,834.1007/01/201008/24/2010

E25 drivers door light is 10/7. needs a new bulb. This is the clear lens light in the lower corner of the drivers door. Thanks HaroldProblem?

Parts QuantityTask performed:

NO PARTS USED

Workorder: V34169

Meter Reading:Close Date:

In Date: 68,550.6008/10/201008/31/2010

Station 25 needs motor oil for all three units please send some if possible. Thanks HaroldProblem?

Parts QuantityTask performed:

Dropped off oil. ja NO PARTS USED

Workorder: V34284

Meter Reading:Close Date:

In Date: 68,566.0008/15/201009/03/2010

Compartment door (driver engineer compartmen)t not closing properly binding when closing no damage reported or observed E25Problem?

Parts QuantityTask performed:

went to 25; fnd linkage nut/bolts loose; tightened/lubed door; ck ok. js

NO PARTS USED

Workorder: V34394

Meter Reading:Close Date:

In Date: 68,566.0008/19/201009/03/2010

E25 pump panel throttle did not work when truck was put in gear on a fire. It took three attempts of taking the pump out of gear & moving the truck a few inchs. On the 3rd attempt the pump thottle did work. E25

Problem?

Parts QuantityTask performed:

Went to 25; ran truck in pump gear w/opr; NPF; ck UPS connections, etc; rem dash panels; fnd park brake switch wires loose; re/ck ok. js

NO PARTS USED

Page 42: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V34910

Meter Reading:Close Date:

In Date: 69,018.0009/13/201009/29/2010

replace rear tires e 25 boulevardProblem?

Parts QuantityTask performed:

Replc rear tires E25 - Boulevard j NO PARTS USED

Vendor?: BOULEVARD TIRE

Workorder: V34905

Meter Reading:Close Date:

In Date: 69,154.0009/13/201010/05/2010

B INSPECTION AND REPAIRS AS NEEDED E 25Problem?

Parts QuantityTask performed:

1. b inspection2. battery box and trash line wont slide, latches and rail full of dirt, clean out slides and latches, test ok.3. r&r wiper blades4. tailboard marker lights out, repaired5. right front handlight inop, inspected , found bad connector, repaired, test ok.6. r&r steering wheel and horn ring7. adjust rear brakes and slack adjusters8. reroute brake chamber suplly lines.9. adjust tire pressure10. check trans oil leak, inspect and found retarder facing downward, reposition valve 11. lube rear calipers12. check for air leaks,found leak in dash, install new dash valve.13. install battery charger with auto eject14. r&r d2 governor15. r&r pump shift valve

10913912CHARGER 2000 10915520120AUTO EJECT 20 AERO OTL3925 2415W40BSYN OIL BULK QTS 12863528635 CONNECTOR HOSE TEE 252-24WIPER BLADES ANCO 24 1538-0180-00SHIFT CONTROL VALVE PUMP ROAD 16804640001NEW# 3184640001 STEERING WHEEL 16814600340A14-15472-000 HORN BUTTON 1800034VALVE PARKING BRK. 1A1818557002HANDLE-WINDOW 15FREIGHTSHIPPING CHARGES 1FS1022FILTER FUEL WIX 33422 PS8689 FRAM 1HPH6349AOIL FILTER 51748 1LML-1350-0113AIR RIDE VALVE (CAB) 1PGL/22019CPIN TURN SIGNAL STEERING WHEEL 10R134AFREON LB 1R802462SLACK ADJ 1R802463SLACK ADJUSTER 1R90PFILTER FUEL 33231 1VHD18537USE 284358 AIR GOVERNOR D-2 KN18537

Page 43: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V35291

Meter Reading:Close Date:

In Date: 69,018.0009/30/201010/18/2010

replace tires at boulevard E 25Problem?

Parts QuantityTask performed:

Replc tires E25 - Boulevard j NO PARTS USED

Vendor?: BOULEVARD TIRE

Workorder: V36887

Meter Reading:Close Date:

In Date: 70,338.7012/05/201001/05/2011

Rear tail board ladder compartment door open switch is broken it needs a new switch installed. Thanks Harold E25Problem?

Parts QuantityTask performed:

Ladder compt door wiring brkn; rep wiring. j 152-624SWITCH DOOR

Workorder: V37474

Meter Reading:Close Date:

In Date: 70,526.2012/28/201001/10/2011

Grab handle inside of drivers door broken. (black plastic closing handle) e25Problem?

Parts QuantityTask performed:

(1) TRAVELED TO ST-25 TO REPAIR GRAB HANDLE IN E25. FOUND THE HANDLE BROKEN AND THE BOLTS THREADS MESSED UP. INSTALLED A NEW HANDLE AND REPAIRED STRIPPED BOLTS. J.W.

16807200575HANDLE DOOR

Workorder: V37418

Meter Reading:Close Date:

In Date: 70,526.2012/27/201001/11/2011

A LOT OF PLAY IN THE BRAKE PEDAL E25Problem?

Parts QuantityTask performed:

(1) TRAVELED TO ST-25 TO REPAIR EXCESSIVE PLAY IN THE BRAKE PEDAL ON E25. ADJUSTED BRAKE PEDAL FREEPLAY. OK. J.W.

NO PARTS USED

Page 44: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V37264

Meter Reading:Close Date:

In Date: 70,526.2012/19/201001/12/2011

Hydrolic line outer surface muffler burn, should be replaced.(not leaking) e25Problem?

Parts QuantityTask performed:

(1) TRAVELED TO ST-25. FOUND HURST HYDRALIC HOSE LINE BURN'T ON E25. REPLACED THE LINE.(2) RIGHT SIDE MIRROR IS LOOSE. TIGHTENED BRACKET AND ADJUSTED.

13530016HOSE HURST 16 ORANGE 1353R091USE 353R403 HURST HOSE 16 GREEN

Workorder: V38042

Meter Reading:Close Date:

In Date: 71,361.0001/25/201101/28/2011

20 foot hurst tool hose has three melted spots which I believe has jepordized the integrity of the hose. Will try to send into shop with the DC or EMS CAPT. Thanks Harold e25

Problem?

Parts QuantityTask performed:

(1) SEE WORK REQUEST, NO LABOR, PARTS ONLY. J.W.

13530016HOSE HURST 16 ORANGE

Workorder: V37874

Meter Reading:Close Date:

In Date: 71,149.5001/18/201102/04/2011

Water leaking from E25 tank estimate the leak is 1/2 gallon per hour inspected area could not locate area where leak originates from (drivers side rear)

Problem?

Parts QuantityTask performed:

Travel to stn; water leak - tank leaking; pinhole L/R lower area of tank. j 2/4/11

2. Rem hose bed dividers & hose bed.3. Rem hose bed; rem tank holddown strap; disconnect tank to pump flange; reconnect tank-to-pump; flushed pump; filled tank; ck for leaks.4. Assist install hose bed.5. put hose bed & dividers back on.6. Work w/vendor on water tank.7. Fill wtr tank & road test.8. A-Inspection. j 2/15/11)

NO PARTS USED

Page 45: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V38404

Meter Reading:Close Date:

In Date: 71,442.6002/09/201102/16/2011

STEP LIGHT OUT E 25Problem?

Parts QuantityTask performed:

Rep steplight. j NO PARTS USED

Workorder: V38524

Meter Reading:Close Date:

In Date: 71,526.0002/15/201102/25/2011

Aux 12 volt plug on officer side 10-7 e25Problem?

Parts QuantityTask performed:

Travel to stn; aux 12V power supply inop - loose connection; rep connection. j

NO PARTS USED

Workorder: V38533

Meter Reading:Close Date:

In Date: 71,616.0002/15/201102/25/2011

Spot light on top of cab not working all of the time possibly a bad bulb or connection problem. Thanks Harold E 25Problem?

Parts QuantityTask performed:

Travel to stn; spotlight inop - spring clip loose; rep search light. j

NO PARTS USED

Workorder: V38804

Meter Reading:Close Date:

In Date: 71,970.3002/27/201103/03/2011

E25 rear A/C not blowing very cold air needs to be checked. Thanks HaroldProblem?

Parts QuantityTask performed:

Clnd rear A/C condensors; pressures are not good; poss A/C compressor or H-block bad; will bring to shop for repair. j

NO PARTS USED

Page 46: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V38807

Meter Reading:Close Date:

In Date: 71,970.3002/27/201103/03/2011

Right side generator compartment door stop bracket is broken needs to be replaced with a new bracket. Thanks Harold E25Problem?

Parts QuantityTask performed:

Traveled to 25; Replc brkn hold open brkt. j NO PARTS USED

Workorder: V39000

Meter Reading:Close Date:

In Date: 72,150.0003/07/201103/17/2011

ON CALL WATER LEAK E 25Problem?

Parts QuantityTask performed:

Went to 25; fnd pump line to vac test port off; rem primer/regulator valves; reinstalled line; ran/ck for leaks; hooked up to hydrant - ck ok; return home. j

NO PARTS USED

Workorder: V38910

Meter Reading:Close Date:

In Date: 72,034.5003/02/201103/21/2011

E25 front dash A/C is not turning on at all tech was just out on 2/28 or 3/1 an recharged system also rear A/C is still blowing hot air. Thanks Harold

Problem?

Parts QuantityTask performed:

1. Travel to stn; fnd bad switch; replc switch temporarily to mk work; will replc w/proper switch.2. Travel to 25; inntall proper A/C switch. j

2ABPN8332229011-3050 SWITCH BLOWER

Workorder: V39206

Meter Reading:Close Date:

In Date: 72,380.3003/15/201103/22/2011

test hose under pump panel cut laeking water vacume gauge. E25Problem?

Parts QuantityTask performed:

Travel to 25; rep water line. j NO PARTS USED

Page 47: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V39999

Meter Reading:Close Date:

In Date: 73,052.5004/19/201104/21/2011

Hands free switch for siren not working on steering wheel. Thanks in advance for help, Sta.25.Problem?

Parts QuantityTask performed:

Travel to 25; cln connection for horn switch. j NO PARTS USED

Workorder: V40121

Meter Reading:Close Date:

In Date: 73,263.3004/25/201104/28/2011

need extra shelf for E-25 Med compartment. 37.5" X 9", sta 25.Problem?

Parts QuantityTask performed:

Install shelf & mov existing shelf. j NO PARTS USED

Workorder: V40237

Meter Reading:Close Date:

In Date: 73,327.4004/28/201105/03/2011

E-25 siren horn button on the steering wheel is broken needs to be repaired! Thanks HaroldProblem?

Parts QuantityTask performed:

Travel to Stn25; C/O steering wheel button; wire brkn on wiper on steering shaft; R/R wiper & rewired. j

NO PARTS USED

Workorder: V40238

Meter Reading:Close Date:

In Date: 73,327.4004/28/201105/03/2011

Officers side pump panel discharge has a light bulb that is burned out. Thanks Harold e25Problem?

Parts QuantityTask performed:

r/R P/P light on R/side L&R light; rep grnds on lights. j

NO PARTS USED

Page 48: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V40598

Meter Reading:Close Date:

In Date: 73,801.8005/13/201105/18/2011

high beam headlights not working possibly wires disconnected when previous work done on steering colume for the siren/horn button. Thanks Harold, Sta 25.

Problem?

Parts QuantityTask performed:

C/O - fnd wires loose in t-signal switch. j NO PARTS USED

Workorder: V40763

Meter Reading:Close Date:

In Date: 73,887.3005/20/201105/25/2011

Airhorn on E25, passenger side horn not operating at all.Problem?

Parts QuantityTask performed:

Adj air horns. j NO PARTS USED

Workorder: V40987

Meter Reading:Close Date:

In Date: 74,157.3005/31/201106/06/2011

Windshield washer sprayer hose tee splitter is broken unable to use to clean windshield. Thanks Harold E25Problem?

Parts QuantityTask performed:

Replc tee fittings for wiper washer. j 2SPR-W58-1TEE PLASTIC

Workorder: V41088

Meter Reading:Close Date:

In Date: 74,279.6006/03/201106/07/2011

E-25 Tractor ABS light is staying on and will not go out. Thanks Harold, Sta 25.Problem?

Parts QuantityTask performed:

Chk ABS; fnd (1) code; R/R sensor; went to chk sensor - brkn; rotor brkn. j

NO PARTS USED

Page 49: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V41131

Meter Reading:Close Date:

In Date: 74,279.6006/06/201106/08/2011

Won't start. Towed to shop.Problem?

Parts QuantityTask performed:

Wont start - towed to shop - Westway j NO PARTS USED

Vendor?: WESTWAY

Workorder: V41152

Meter Reading:Close Date:

In Date: 74,279.6006/06/201106/13/2011

Brake rotor broken.Problem?

Parts QuantityTask performed:

1. Rep rear brakes; replc rotor, grease seal & axle gskt right side; adj wheel bearing to specs; torque all fasteners to spec.2. Work on rear brakes.3. Rear brakes; replc R/wheel speed sensor; grease calipers & adj. j

13218K167ROTOR-BRAKE 1380003ASEAL 1401581GASKET AXLE FL80 R002435 1A13263M1157CALIPER ASSY ENGREAR L/H 1A23263M1157CALIPER ASSY ENG REAR R/H 1KIT15625PMAXEL SET 1S4410325140R955342 SENSOR REAR ABS 4410328140

Workorder: V41464

Meter Reading:Close Date:

In Date: 74,322.3006/20/201106/20/2011

foam system inop, abs light on. Sta 25.Problem?

Parts QuantityTask performed:

1. Travel to Stn25; fnd switch on distribution box in off position; turned switchon; foam sys ok.2. Tried to hookup laptop for ABS codes; wld not connect; erased codes mannually & test drove - ok; inspected sensors & wires (old). j

NO PARTS USED

Page 50: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V41196

Meter Reading:Close Date:

In Date: 74,295.0006/08/201106/27/2011

C INSPECTION AND REPAIRS E 25Problem?

Parts QuantityTask performed:

Page 51: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

C-Inspection2. Svc btrys.3. Replc belts.4. P/S svc.5. Replc L1 door brkt; drill holes larger & grind bottom edge to fit properly; tighten holdopen linkage bolts.6. Dia problem with rear compt door latch; replc handle - cut handle actuator to size; drill out holes in handle larger for hole alignment; make gskt for handle; grind diamond plate for flush fit; lube.7. Tighten L-3 shelf bolts; tighten all door holdopen bolts & toot brkts.8. Svc gen.9. Cln rear A/C filter.10. Replc drivers door weatherstrip & rocker cvr bolts; vac dirt under rocker cvr.11. Perform dry vac test; fnd leak at test port; replc test port plug & wrapped plug w/teflon tape.12. Adj tire press.13. Replc wiper blades.14. Install msng intake strainer R/side & pos L/strainer correctly.15. Replcd btry-on & ign-on indicator lights.16. Replc bulb R/side fender marker light.17. Replc bulb rear hydrant wrench light.18. Replc L/side marker light asy; drill out fixture to accommodate large sheet metal screws.19. Replc R/rear side marker bolts stripped out; install larger sheet metal screws & drill out fixture for larger screws.20. Replc rear center tailboard marker light; rep bad grnd & replc bolts w/longer ones for grnd wire attachment.21. Replc light bar emergency swtich & compt light switch; no switches in parts dept; Ohm out - similar switches for poss replacement; search svc trks for correct switches; fnd (2) on airport truck; replc switches & test ok.22. Replcd switch labels for lighting; print label for wigwag blnk.23. Replc air filter & msng nuts/washers; replcd bolts, nuts & washers for fender skrt.24. Replc ladder heat sensors & inspect ladders.25. Chk eng, trans & ABX codes.26. Svc dryer & purge valve; protect air line & secure.27. T-case svc.28. Svc rear axle.29. Top off washer fluid/trans fluid.30. Press chk cooling sys; fnd bad rad cap; replc cap.31. Fill wtr tank.32. Tighten oil pan bolts, degrease motor.33. Rebuild L/in take valve; R/R drain valve for access.34. Cut plastic labels to size for #2 discharge & relief valves; print labels & apply to plackard.35. Recover, evac & charge rear A/C; leak test sys.

105-17223-000CAP RADIATOR 10 LB 10769027STRAINER 2.5 IN 1101305002DH0007-5 BRACKET RIGHT 1107796DRYER KIT AD9 -NEW 2715W40BSYN OIL BULK QTS 323-11345-710SCREW DASH 3330-3009COVER GASKET 235200-RLIGHT MARKER LED RED 135200-YLIGHT MARKER LEDAMBER 1372000030BATTERY ON DISPLAY 1372000031IGNITION ON DISPLAY 252-24WIPER BLADES ANCO 24 16806970098SEAL DOOR 179L-SSD RING LATCH 1800405PURGE VALVE KIT 191388906 VALVE KIT 2.5 IN AKRON 19440BELT 19480BELT 1A1834388003MOLD R/H 1BPR5ESSPARK PLUG 7734 1CA8193AIR FILTER 46744 WIX 1F6DZ-8100-A9C3Z8101B RADIATOR CAP 10238 STANT 1FS1022FILTER FUEL WIX 33422 PS8689 FRAM 1HPH6349AOIL FILTER 51748 1K080716BELT 1PR338324070 WIX FILTER WATER 1R90PFILTER FUEL 33231 1TRANSYNDALLISON TRANS FLUID GAL 1VML-S1414FILTER P/S 1VML-T1264GASKET P/S COVER

Page 52: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

36. Quality check.37. Replc R/rear door trim piece; R/R door panel; install larger diameter sheet metal screws where holes are stripped; replc bolt in handle.38. Dia pump panel lights going off; cut left, right & center wires & chk AMP draw - ok; rem R-1 compt shelf & class one panel cvr; rem brkr & chkd AMP draw - ok; replc weak brkr; heat shrink wire connections & reinstall cvr & shelf. j

Workorder: V27446

Meter Reading:Close Date:

In Date: 63,641.7001/01/190008/02/2011

2 1/2 float pump leaks and won't pull draft E25Problem?

Parts QuantityTask performed:

nothing found in file. 148-0014SILICONE SEALER 249-0025SEAL 149-0029GASKET 2EP2503GASKET

Workorder: V42622

Meter Reading:Close Date:

In Date: 75,140.0008/07/201108/17/2011

condensation vapor or freon vapor coming from bottom rt. of rear a/c unit E25Problem?

Parts QuantityTask performed:

Fnd fitting at expansion valve leaking on lo-side hose thru floor; rem rear ___; rep end of hose w/new crimp fitting; charged sys after vac test; passed - all ok. j

108-5063BFITTING A/C 4391 1160012-2012A EXPANSION VALVE 71R8301 174R258607-2613A RED DOT DRIER 7127

Workorder: V42856

Meter Reading:Close Date:

In Date: 75,277.9008/16/201108/19/2011

Spot light is stuck. Does not articulate. E 25Problem?

Parts QuantityTask performed:

checked light found loose screws in base plate causing gears not to mesh secured screws

NO PARTS USED

Page 53: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V42865

Meter Reading:Close Date:

In Date: 75,334.6008/17/201108/19/2011

Siren/horn switch on the steering wheel is not working all the time possibly a bad wire conection. Thanks Harold, Sta 25.Problem?

Parts QuantityTask performed:

travel to 25 repaired contact for horn 16804640043HORN CONTACT

Workorder: V44260

Meter Reading:Close Date:

In Date: 76,197.4010/10/201110/13/2011

MINOR WATER LEAK COMING FROM A COMPRESSION FITTING LOCATED BY THE TOP RADIATOR HOSE/ROUND MANFOLD E25

Problem?

Parts QuantityTask performed:

Travel to 25; rep wtr leak at eng cooler. j NO PARTS USED

Workorder: V45412

Meter Reading:Close Date:

In Date: 11/25/201111/30/2011

need hydralic fluid for hurst power unit. E25Problem?

Parts QuantityTask performed:

Travel to Station 25; Drop off Hurst oil. bp 1180R002HURST HYD. FLUID QT

Workorder: V45686

Meter Reading:Close Date:

In Date: 12/06/201112/07/2011

Rear red marker light & right side yellow marker light 10/7 e 25Problem?

Parts QuantityTask performed:

replaced dim led marker lights 135200-RLIGHT MARKER LED RED 135200-YLIGHT MARKER LEDAMBER

Page 54: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V46692

Meter Reading:Close Date:

In Date: 77,735.6001/19/201201/23/2012

Pigtail for shoreline did not disengage when responding. Lost enroute to call. E25Problem?

Parts QuantityTask performed:

TRAVEL TO 25 CHECKED AUTO EJECT WORKING FINE NO PROBLEM FOUND.

NO PARTS USED

Workorder: V46926

Meter Reading:Close Date:

In Date: 77,960.5001/30/201201/30/2012

Rear brakes getting hot and air guage going down.Problem?

Parts QuantityTask performed:

TRAVEL TO STA 25 - CHECK TEMP ON R. WHEEL 245 DEGREE. CHECK TEMP ON LEFT 103. CHECK AIR SYSTEM FOR LEAKS AND GAUGE CUT OFF AND ON (OK) REMOVE CALIPAR RELIEF RLUG AND CLEVIS PINS. ADJUST CALIPER ALL THE WAYOUT AND BACK IN. ADJUST R. CALIPER FOR PROPER ADJUST LUBRICATE CLEVIC PINS AND INSTALL. CHECK BRAKE ADJUST LEFT SIDE - FOUND ADJUST TOO LOOSE. ADJUST LEFT BRAKE. TEST DRIVE BRAKES. AIR GAUGE NORMAL DROPS AFTER BEING OFF ACCELERATOR PEDAL DUE TO RETARDER ON ACCELERATOR INSTEAD OF BRAKE. CHECK TEMPS AFTER RETURNING TO STATION (OK)

NO PARTS USED

Workorder: V47011

Meter Reading:Close Date:

In Date: 78,327.1002/01/201202/28/2012

Crosslay hose cover is missing a twistlock grommet and all of the rest are old and worn out both sides of the crosslays. They should all be replaced. The covers are coming loose every time the Engine goes on the road.

Problem?

Parts QuantityTask performed:

INSTALLED NEW TWIST LOCKS. NO PARTS USED

Page 55: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V47068

Meter Reading:Close Date:

In Date: 78,024.9002/03/201202/28/2012

right rear spot light burnt outProblem?

Parts QuantityTask performed:

FOUND SWITCH WIRE DISCONNECTED CORRECTED. 14007BULB NIGHT FIGHTER 14435HEADLIGHT

Workorder: V47486

Meter Reading:Close Date:

In Date: 78,327.1002/22/201202/29/2012

ON CALL BRAKES HANGING UP E 25Problem?

Parts QuantityTask performed:

TRAVEL TO ST 25. DRIVER SAID ROAD TECH ADJUSTED REAR BRAKES RECENTLY CHECKED BRAKE OPERATION DETERMINED BRAKE CHAMBER BAD R&R L/R BRAKE CHAMBER.

1MA15445NT3030 STD CHAMBER 30/30

Workorder: V47838

Meter Reading:Close Date:

In Date: 78,712.1003/09/201203/15/2012

18 volt Dewalt Drill Battery won't hold a charge. Replacement requested per D/C 2 Cooper, Sta 25Problem?

Parts QuantityTask performed:

TRAVEL TO ST 25 CHECK OUT BATTERY. DROP OFF NEW BATTERY.

NO PARTS USED

Workorder: V47750

Meter Reading:Close Date:

In Date: 78,601.5003/05/201203/19/2012

Right front head light is 10/7. Needs to be replaced. Thanks Harold E 25Problem?

Parts QuantityTask performed:

INSTALLED NEW HEAD LIGHT TRAVEL TO STATION. 1H6054USE CV TYPE SEALED BEAM

Page 56: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V47482

Meter Reading:Close Date:

In Date: 78,764.5002/22/201204/04/2012

Booster line switch for reel not working E 25Problem?

Parts QuantityTask performed:

DIAGNOSE HOSE REEL WORKING INTERMITTANTLY. REMOVE PANEL TO ACESS SWITCH. REMOVE WIRES AND CHECK SWITCH WITH OHM METER (OK) CLEAN WIRE TERMINALS, INSTALL SWITCH AND PANEL. REMOVE HOSE REEL PIPE CAP TO FACILITATE REMOVAL OF COMPARTMENT DIVIDER. SCREWS IN DIVIDER FROZEN IN BODY AIR CHIESLE HEADS OFF SCREWS. GRIND DOWN SCREW THREADS IN PANEL HOLES TO FACILITATE REMOVAL OF PANEL. REMOVE BLOCKING FROM COMPARTMENT AND REMOVE PANEL. REMOVE SCREWS FROM COVER COVERING RELAY AND BREAKER. FOUND BREAKER RUSTED OUT AND CABLES CORRODED. REPLACE BREAKER, MAKE UP NEW WIRE JUMPERS AND TERMINAL ENDS. HEAT SHRINK TERMINALS. REMOVE MOTOR GROUND, CLEAN GROUND SURFACE AND TERMINAL. INSTALL GROUND WITH DIELECTIVE GREASE AND TIGHTEN. CLEAN TERMINALS ON RELAY AND TIGHTEN. APPLY SILICONE DIELECTRIC GREASE TO RELAY TERMINALS. TEST HOSE REAL (OK). REINSTALL ALL COVERS AND VLOCKING. DRILL AND THREAD. NEW HOLES WERE NEEDED.

NO PARTS USED

Page 57: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V47961

Meter Reading:Close Date:

In Date: 78,764.5003/14/201204/10/2012

B INSPECTION E 25Problem?

Parts QuantityTask performed:

Page 58: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

B inspectionOil and filter changerelearn tpm sensorsreplace pinon seal and rear diff sealreplace brake light switchreplaced throttle body1. B-Inspection.2. B-Inspection.3. Diagnose pump water leak. Found leak at tank to pump valve handle. Drain water tank, remove drive shaft and valve linkage remove pump cover. Removed valve. Rebuild valve and reinstall everything. Fill water tank, run pump and check for leaks.4. Service batteries, load test, clean terminals and connections.5. Top off r f wheel grease.6. L rear brake chamber not set up correctly. Reset adjustments.7. Install l rear seat belt trim piece.8. A/C hose resting on exhaust and l and right wiring harnesses not bundled up. Secure harnesses with tie straps.9. Diagnose oil leaking from retarder accumulator exhaust hose. Found seals in accumulator bad. Remove air line electrical wires, transmission line and accumulator. Disassemble, clean and rebuild accumulator. Replace accumulator activation solenoid. Switch over fittings seal threads on all fittings. Install accumulator trans hose, air line and wires. Road test vehicle and check for operation and leaks. Install body access side plate.10. L R brake hoses laying on rear differential. Cage brake chamber, loosen clamp bolts and rotate center part of chamber upwards. Tighten bolts. Adjust position of fittings. Attach frame clamp on frame to hold hoses in position.11. Diagnose oil leak. Degrease motor. Run vehicle and inspect for leaks. Found leak rear of motor. Tighten oil pan bolts. Clean area and test drive vehicle and recheck for leaks ok.12. Adjust all tires to proper pressure.13. Diagnose no MIV indicator lights. Check terminal plug connection (OK)> Check for power and ground (No power). Trace wiring to fuse. Check fuse and holder (No good) Replace fuse and holder. Splice wiring and heat shrink connections. Install wire loom to protect wiring and tie strap to secure test lights open and midway working. Closed position light not working. Check bulb (no good). Replace blub and recheck ok.14. Rebuild primer valve. Elongate holes in pump panel and rethread valve housing. Tighten compression fittings test ok.15. Diagnose rear a/c only cool. Leak check system (OK) recover freon. Evacuate system and charge with

1042-0091-00SPRING PRIMER 12952271729552377 VALVE ASSY.ACCUM 129535973ACCUM.KIT 130055-50THERMAL BREAKER 50 AMP 1304092530409-25 FUSE 139008USE 39045 KIT 152-624SWITCH DOOR 291398907 VALVE KIT 3 IN AKRON 1FS1022FILTER FUEL WIX 33422 PS8689 FRAM 1HPH6349AOIL FILTER 51748 1MA15445NT3030 STD CHAMBER 30/30 1PVG-KITORING KIT 1R90PFILTER FUEL 33231 1TV426-026SAW GAURD

Page 59: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

correct amount of freon. Run vehicle and perform performance test ok.16. Diagnose rear compart. light not working from right hand door. Found bad wiring at rear switch plug. Removed switch, replaced wire terminal splice wires and heat shrink connections. Install wire loom to protect. Test OK. Shave down connector to fit through hole.17. Raise vehicle and place on jacks. Check wheel bearings and adjust. Check steering linkages and king pins. Check steering shaft u-joints. Lubricate U-joints.18. Check trans fluid low. Add 2 qts. trans fluid and test drive until vehicle is hot and recheck level. A little to high. Drain small amount and recheck ok.19. Diagnose fuel leak - found leak at line fitting on lift pump. Tighten line, clean area. Test run vehicle and check for leaks ok.20. Diagnose P/S leak - found loose fitting at gear box tighten fitting. Clean area. Test run vehicle and recheck.21. Hurst tool tray loose - tighten all fasteners.22. Check ABS system for codes - found one inactive code for R rear wheel speed sensor. Erase code, check resistance of sensor (OK). Test drive vehicle and check for a reoccurring code. Code came back. Push sensor in and erase code.23. Compt switch light in/op. no correct switch in parts dept. tryed to OHM out switch fromparts and place in vehicle. Will not work. Return to parts dept. and install old switch back in panel.SEE REPORT IN FILE FOR REST OF INSPECTION.

Workorder: V48225

Meter Reading:Close Date:

In Date: 78,764.5003/27/201204/10/2012

Engine surges when pumping. E 25Problem?

Parts QuantityTask performed:

RAN TRUCK A ND PUMP FOUND PUMP THROTTLE SURGING REPLACED THROTTLE CHECKED OK.

155790-1350000008 ELECTRONIC THROTTLE 100076 FELS

Workorder: V48500

Meter Reading:Close Date:

In Date: 79,074.2004/07/201204/24/2012

driver rear red strobe light has a blown bulbProblem?

Parts QuantityTask performed:

INSTALLED NEW FLASHER NO PARTS USED

Page 60: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V49485

Meter Reading:Close Date:

In Date: 79,901.8005/19/201205/31/2012

Generator on E-25 will not run unless choke is left on. Once choke is taken off the unit will sputter and sound like it is about to stall E25

Problem?

Parts QuantityTask performed:

TRAVEL TO 25 REBUILT CARB AND FUEL SHUT OFF VALVE TESTED RUNS GOOD.

NO PARTS USED

Workorder: V49928

Meter Reading:Close Date:

In Date: 80,358.9006/06/201206/07/2012

Power steering pump is leaking. E 25Problem?

Parts QuantityTask performed:

CHECKED FOR P.S. LEAK FOUND BACK PLATE OF STEERING GEAR LEAKING SWAP OUT AND SENT TO SHOP.

NO PARTS USED

Workorder: V49980

Meter Reading:Close Date:

In Date: 80,358.9006/08/201206/14/2012

STEERING BOX LEAKS E 25Problem?

Parts QuantityTask performed:

1. REPLACE GEAR BOX. BLEED SYSTEM OF AIR AND SET STOPS. TEST DRIVE (OK).2. REMOVE AND REPOSITION STEERING WHEEL.

1RGTTAS65052ASTEERING GEAR BOX FRTLNR. ENG.

Workorder: V50805

Meter Reading:Close Date:

In Date: 80,899.4007/12/201207/18/2012

E-25 cab is leaking water through the roof possibly at the welded seam. Thanks HaroldProblem?

Parts QuantityTask performed:

RESEALED ROOF LINE AND ANTENNAS NO PARTS USED

Page 61: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V50806

Meter Reading:Close Date:

In Date: 80,899.4007/12/201207/18/2012

F/F rear door thresh hold plastic plate is broken possibly could cause an injury when f/f enters or exits the cab. Thanks Harold E25Problem?

Parts QuantityTask performed:

TRAVEL TO 25 REPLACED THRESHOLDS IN REAR COMPARTMENT.

16806840018DOOR SILL L/H 16806840118DOOR SILL R/H

Workorder: V50877

Meter Reading:Close Date:

In Date: 80,935.2007/16/201207/19/2012

REAR TIRES AT THE WEAR BARS AND LEFT FRONT CLOSE TO WEAR BARS. e 25Problem?

Parts QuantityTask performed:

TRAVEL TO 25 CHECKED TIRES OK. NO PARTS USED

Workorder: V51020

Meter Reading:Close Date:

In Date: 80,935.2007/20/201208/01/2012

repalce 5 tiresProblem?

Parts QuantityTask performed:

REPLACE 5 TIRES. NO PARTS USED

Vendor?: BOULEVARD TIRE CENTE

Workorder: V51162

Meter Reading:Close Date:

In Date: 81,221.8007/27/201208/01/2012

E25 trash line compartment door latch is broken door is still held closed with 2nd latch on opposite side of door. Thanks HaroldProblem?

Parts QuantityTask performed:

TRAVEL TO 25 REPLACED BROKEN DOOR LATCH. 1101291015434 LATCH TRIGGER S/O

Page 62: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V51374

Meter Reading:Close Date:

In Date: 81,324.5008/05/201208/13/2012

E-25 portable generator not working properly will not run all the time and leaking fuel at carborator. Thanks HaroldProblem?

Parts QuantityTask performed:

SWAPPED OUT GENERATOR WITH SPARE UNIT. NO PARTS USED

Workorder: V52070

Meter Reading:Close Date:

In Date: 81,907.5008/31/201209/06/2012

a/c blower inopProblem?

Parts QuantityTask performed:

1.TTRAVEL TO 25 REPLACED BLOWER SWITCH 1ABPN8332229011-3050 SWITCH BLOWER

Workorder: V51375

Meter Reading:Close Date:

In Date: 08/05/201209/14/2012

E-25 TAILBOARD MARKER LIGHT IS 10/7 THANKS HAROLDProblem?

Parts QuantityTask performed:

1. REPLACED MARKER LIGHT AND LFT HEADLIGHT. 135200-RLIGHT MARKER LED RED 1H6054USE CV TYPE SEALED BEAM

Workorder: V51853

Meter Reading:Close Date:

In Date: 08/23/201209/17/2012

Shop mech. was at station working on R-25. When I asked him to check the front head light on E-25 which he had just replaced a shift or two ago it was now full of water. He replaced it with a new bulb. Thanks Harold

Problem?

Parts QuantityTask performed:

REPLACED LFT HEADLIGHT. 1H6054USE CV TYPE SEALED BEAM

Page 63: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V52231

Meter Reading:Close Date:

In Date: 09/07/201209/19/2012

Marker light on top of cab is 10/7 it is the light in the middle of the cab. Thanks Harold... E25Problem?

Parts QuantityTask performed:

R&RMARKER LIGHT BULB. NO PARTS USED

Workorder: V52281

Meter Reading:Close Date:

In Date: 09/10/201209/19/2012

Light bar on top of cab wig-wag has a white light bulb that is 10/7. thanks Harold. E25Problem?

Parts QuantityTask performed:

1. TRVL TO 25 PIERCER LIGHT SHORTED OUT WILL GET NEW ONE AT SHOP TO REPLACE.2. TRVL TO 25 REPLACED PIERCER LIGHTS IN LIGHT BAR.

102038247700OBSOLETE OCSILLATER PIERCER ALERT

Workorder: V52852

Meter Reading:Close Date:

In Date: 10/04/201210/12/2012

Pump panel discharge white light on driver side is 10/7. Thanks Harold E-25Problem?

Parts QuantityTask performed:

REPLACED PUMP PANAL LIGHTS. NO PARTS USED

Workorder: V52853

Meter Reading:Close Date:

In Date: 10/04/201210/12/2012

Red marker light at rear on driver side next to red warning light is 10/7 mounting base is broken and some LED elements are burned out. Thanks Harold

Problem?

Parts QuantityTask performed:

TRVL TO 25 REPLACED MARKER LIGHT AND HOUSING.

1372000082CHROME MARKER LIGHT MOUNT 1372000083GASKET MOUNTING 1372000084MARKER LIGHT 1372000085HARNESS FOR MARKER LIGHT 1S777COUPLING NIPPLE

Page 64: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V53193

Meter Reading:Close Date:

In Date: 82,854.6010/19/201210/26/2012

step light on rear of e25Problem?

Parts QuantityTask performed:

TRAVEL TO ST 25 CHECK OUT STEP LIGHTS R&R BULB IN ONE REPAIR GROUNDS ON THE OTHERS.

NO PARTS USED

Workorder: V49069

Meter Reading:Close Date:

In Date: 79,576.8011/20/201211/20/2012

E25 pump test full capacity test failedProblem?

Parts QuantityTask performed:

CORRECTED PROBLEM RETESTED PASSED. 15462270020VALVE KIT SS 546-2270-02-0 15462280020VALVE KIT 2 IN SS VALVE 546-2280-02-0 15462290020VALVE KIT SS VALVE 2 1/2 546-2290-02-0 15462300020VALVE KIT SS VALVE 3 IN

Workorder: V54141

Meter Reading:Close Date:

In Date: 12/03/201212/05/2012

handle on 2 1/2" playpipe nozzle boke during fire cal, needs replaced E25Problem?

Parts QuantityTask performed:

TRAVEL TO 25 NOZZLE ALREADY AT H.Q. 1215W40QSYN OIL QT

Page 65: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V54427

Meter Reading:Close Date:

In Date: 84,078.6012/13/201201/09/2013

C INSPECTION E25Problem?

Parts QuantityTask performed:

Page 66: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

1. C INSP2. C INSP3. CHARGED TRANS CODER.4. SERVICED TRANS.5. REBUILT AIR BRAKE DRYER.6. TORQUED U-BOLTS.7. R&R AIR BRAKE COMPRESSOR COOLANT LINES TO REPLACE SEALS.8. REPLACED UPPER RADIATOR HOSES AND CLAMPS FILLED CODING SYSTEM PRESSURE TESTED (NO LEAKS FOUND). STARTED TRUCK TOPPED OFF TRANS AND COOLING SYSTEM.9. PULLED DASH APART REMOVED A/C CONTROL LUBED, ADJUSTED LINKAGE TO DEFROSTER AND LUBED (FROZEN/BINDING) BENT BRACKET BACK IN PLACE FOR CABLE HOLD DOWN. ALSO REROUTED CABLE FOR SMOOTH OPERATION.10. REPLACED WIPER BLADES.11. LUBED TIGHTENED AND ADJUSTED ALL BODY DOOR HINGES, LATCHES AND HOLDOPENS.12. ADJUSTED PUMP PANEL ACCESS DOOR SO RELEASE BUTTON WOULD NOT HANG UP ON OPENING AND LUBED.13. REPLACED DOOR OPEN SWITCH FOR LADDER COMPARTMENT DOOR. (BROKEN).14. REPLACED 3 DOOR WEATHERSTRIP 3 DOOR TRIMS 3 OUTTER DOOR HANDLE/LATCHES AND LUBBED ALL WINDOW MECHS.15. PAINTED FUEL CAP.16. REPLACED OUTSIDE DOOR HANDLE/LATCH ASSEMBLY REPLACED DOOR TRIM DOOR WEATHERSTRIP. LUBBED WINDOW REGULATOR, HINGES AND DOOR CHECK.17. REMOVED WATER CONTAMINATED GEAR OIL FROM LEFT FRONT WHEEL HUB REMOVED WHEEL HUB CAP CALIPER ASSEMBLY BRAKE PADS HUB AND WHEEL SEAL CLEAND ALL PARTS AND REASSEMBLED WITH NEW SEAL FILLED WITH FLUID.18. UNFREEZE, CLEANED AND LUBED BATTERY TRAY PULLOUT DRAWER AND TRASHLINE PULLOUT DRAWER (FROZED/SIEZED).19. SECURED TIRE VALVE EXTENSION HOSES ON REAR TIRES (LOOSE).20. REPLACED 3 FROZED EASY LOCKS ON REAR OF TRUCK.21. CHECKED OUT CITY HORNS INOP. TRACED PROPERLY TO FAULTY SET OF HORNS. REPLACCED CITY HORNS.22. ROAD TESTED TRUCK CHECKED FOR COOLANT LEAKS AND TOPPED OFF COOLANT RESEVOIR.23. DURING ROAD TEST IT WAS NOTICED THAT FRT A/C FAN WAS NOT WORKING. TRACED PROBLEM TO RELAY FALLING OUT OF TECH PANEL. SECURED

205-16423-000HOSE LOWER RADIATOR 1107796DRYER KIT AD9 -NEW 1107800VALVE CHECK AD9 114022-1-5COOLER 14032 118-29935-001RH DOOR LATCH NEW 129526898 29548988 TRANS FILTER ALLISON 4330-3024HUB COVER GASKET 1370001ASEAL 35066 252-24WIPER BLADES ANCO 24 152-624SWITCH DOOR 26806970098SEAL DOOR 26807600070HANDLE DOOR EXT L/H 26807600170HANDLE DOOR EXT. R/H 1800405PURGE VALVE KIT 1980-412173 MIRROR 8 IN 1A0631117000HORN HIGH NEW # 06-52125-039 1A0631117003HORN LOW NEW #06-52125-041 2A1834388002MOLD L/H 2A1834388003MOLD R/H 2CA8193AIR FILTER 46744 WIX 1FS1022FILTER FUEL WIX 33422 PS8689 FRAM 1HPH6349AOIL FILTER 51748 2PR338324070 WIX FILTER WATER 1R90PFILTER FUEL 33231 4S1003-A3103015 SEAL

Page 67: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

RELAY A/C IS NOW WORKING PROPERLY.24. REPLACED DRIVER'S SIDE SPOT MIRROR (CRACKED).25. Q.A INSPECTION-CHK OK.

Workorder: V54959

Meter Reading:Close Date:

In Date: 84,165.0001/09/201301/10/2013

WONT START E 25Problem?

Parts QuantityTask performed:

1. REPACED FAULTY STARTER.2. ASSIST IN STARTER REPLACEMENT.

1104610896386 NEW STARTER 37MT 1993928

Workorder: V55679

Meter Reading:Close Date:

In Date: 84,983.9002/10/201302/12/2013

E25 needs full assortment of sawsall blades for milwaukee electric sawsall Thanks HaroldProblem?

Parts QuantityTask performed:

TOLD CAPT. TO CHECK WITH BATT H.Q. FOR BLADES.

NO PARTS USED

Workorder: V56354

Meter Reading:Close Date:

In Date: 85,582.7003/12/201303/14/2013

Marker light is 10/7 on top of cab on the driver side. Thanks HaroldProblem?

Parts QuantityTask performed:

TRAVEL TO 25 REPAIRED MARKER LIGHT. NO PARTS USED

Workorder: V56639

Meter Reading:Close Date:

In Date: 85,967.3003/25/201303/26/2013

Install step and strap for new 5" hoseProblem?

Parts QuantityTask performed:

INSTALL STEP AND TIE DOWN STRAP FOR 5" HOSE. 1SAHSVS2510STRAP

Page 68: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V56827

Meter Reading:Close Date:

In Date: 86,217.1004/04/201304/09/2013

Low voltage alarm E-25Problem?

Parts QuantityTask performed:

TRAVEL TO 25 CHECKED SYSTEM ALTERNATOR NOT CHARGING. R&R ALTERNATOR.

14867JB320 UPGRADE ALTERNATOR

Workorder: V56072

Meter Reading:Close Date:

In Date: 85,291.7002/28/201304/16/2013

remove hood for E-25Problem?

Parts QuantityTask performed:

1. CHARGE AND JUMP START VEHICLE. REMOVE STROBE LIGHTS AND LENSES. REMOVE CABLE TIES AND ELECTRICAL CLAMPS. REMOVED AIR HORN AIRLINES. REMOVED HOOD FROM PARTS TRUCK 10132040.2. ASSIST WITH ALL ABOVE REPAIRS.3. WAX HOOD.4. REMOVE HOOD FROM E-25 AND INSTALL PARTS TRUCK HOOD 10132040 ON E-25. SWITCH OVER GRILL AND SECURE WIRING. CONNECT STROBES AND AIR HORN LINE. TEST LIGHTS AND STROBES AND AIR HORN OK.5. INSTALL HOOD WITH BYRUM.

NO PARTS USED

Workorder: V55678

Meter Reading:Close Date:

In Date: 02/10/201304/18/2013

E-25 hood hinge on the driver side is seperating from the fiber glass mounting area tearing the fiber glass every time the hood is opened and could be harmful to person opening hood if it detatches totally Thanks Harold

Problem?

Parts QuantityTask performed:

NO PARTS USED

Page 69: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V57830

Meter Reading:Close Date:

In Date: 05/19/201305/29/2013

Rear AC not working properly.Problem?

Parts QuantityTask performed:

TRAVEL TO ST 25 CHECK OUT SYSTEM ADD FREON AND CHECK FOR LEAKS CHK OK.

NO PARTS USED

Workorder: V58675

Meter Reading:Close Date:

In Date: 87,908.0006/25/201306/28/2013

officer side front tire is down to the tread bars needs to be replaced Thanks HaroldProblem?

Parts QuantityTask performed:

OFFICER SIDE FRONT TIRE IS DOWN TO THE TREAD BARS NEEDS TO BE REPLACED THANKS HAROLD.

115886311R22-5 R260 B STONE

Vendor?: BOULEVARD TIRE CENTE

Workorder: V59028

Meter Reading:Close Date:

In Date: 88,104.0007/12/201307/19/2013

Right front turn signal outProblem?

Parts QuantityTask performed:

CHECKED LIGHTS ALL OK. NO PARTS USED

Workorder: V59135

Meter Reading:Close Date:

In Date: 88,205.4007/16/201307/19/2013

Air filter warning light in cab is intermittantly going on and off. Do not know if the filter is bad or if the sending unit has a problem. Thanks Harold

Problem?

Parts QuantityTask performed:

TRAVEL TO 25 REPLACED SENSOR FOR AIR CLEANER.

1136578-07825AIR RESTRICION SENSOR 122-51374-000SENSOR AIR RESTRICTION

Page 70: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V59156

Meter Reading:Close Date:

In Date: 88,205.4007/17/201307/19/2013

Left side flood lights not working. (left side pump panel)Problem?

Parts QuantityTask performed:

CHECKED SCENE LIGHTS FOUND PLUG GOING TO LIGHT MELTED REWIRED PLUG OK.

NO PARTS USED

Workorder: V59426

Meter Reading:Close Date:

In Date: 88,348.0007/29/201307/31/2013

CHECK UNIT SLOWW CRANKING BATTERIES 3 YRS OLD E 25Problem?

Parts QuantityTask performed:

TRAVEL TO 25 REPLACED ENGINE BATTERIES. 4BATTERY EPA TAXBATTERY EPA TAX $1.50 PER BATTERY 4HP-31DBATTERY 950CCA HP-31D

Workorder: V59631

Meter Reading:Close Date:

In Date: 88,474.0008/06/201308/07/2013

A/C inopProblem?

Parts QuantityTask performed:

1. A/C COMPRESSOR LOCKED UP - RECOVER - FREON, REMOVE COMPRESSOR. CHECK AMOUNT OF AOIL. CHECK OIL AMOUNT IN NEW COMPRESSOR AND ADD PROPER AMOUNT. INSTALL COMPRESSOR AND VACUUM SYSTEM. REPLACE BELT. SPLICE WIRE CONNECTION AND HEAT SHRINK CONNECTION. VACUUM LEAK CHECK. CHARGE SYSTEM AND PERFORMANCE CHECK SYSTEM OK. R&R AIR CLEANER AND FENDER SKIRT FOR ACCESS.2. REPLACE L/FRONT HEADLIGHT.

1576403-3470 COMPRESSOR A/C 5720 19440BELT 1A2245482000 12-0615A VALVE EXPANSION FTRLNR 1606 1H6054USE CV TYPE SEALED BEAM

Page 71: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V59598

Meter Reading:Close Date:

In Date: 88,474.0008/05/201308/09/2013

a/c in back of cab not working.Problem?

Parts QuantityTask performed:

CHECKED A/C NO PROBLEM FOUND. NO PARTS USED

Workorder: V59599

Meter Reading:Close Date:

In Date: 88,474.0008/05/201308/09/2013

compartment door open buzzer not signaling in cab when doors on right side of apparatus are open.Problem?

Parts QuantityTask performed:

TRAVEL TO 25 REPLACED SHORTED RELAY FOR DOOR AJAR CIRCUIT.

NO PARTS USED

Workorder: V59606

Meter Reading:Close Date:

In Date: 88,474.0008/05/201308/09/2013

replace headlightProblem?

Parts QuantityTask performed:

CHECKED LIGHTS ALL OK. 1H6054USE CV TYPE SEALED BEAM

Workorder: V59879

Meter Reading:Close Date:

In Date: 88,776.1008/18/201308/20/2013

Head light on officers side is 10/7 possibly needs to be replaced. Thanks Harold E25Problem?

Parts QuantityTask performed:

TRAVEL TO 25 R&R HEADLIGHT. 2H6054USE CV TYPE SEALED BEAM

Page 72: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V60181

Meter Reading:Close Date:

In Date: 88,945.6008/30/201309/05/2013

Booster reel rewind is 10/7 possibly the motor is froze up. Thanks HaroldProblem?

Parts QuantityTask performed:

TRAVEL TO 25 TWICE TO CATCH AT STATION. BOOSTER REEL INOP POWER AND GROUND GOOD REPLACED BOOSTER REAL MOTOR AND GEAR. WHILE WINDING UP HOSE SOLENOID WENT BAD NO POWER THROUGH SOLENOID. REPLACED SOLENOID AND TESTED ROLLED UP HOSE OK.

19910-1119GEAR CHAIN DRIVE HANNA 1P56AN227MOTOR HOSE REEL 1SS598STARTER SOLENOID FORD TYPE

Workorder: V61437

Meter Reading:Close Date:

In Date: 89,449.0010/22/201311/19/2013

B inspection old E25 - will become spareProblem?

Parts QuantityTask performed:

1. B INSP.2. REMOVE EXHAUST BRACKET FROM SPARE ENGINE INSTALL ON E-25.3. REMOVE R/F WHEEL COVER AND REPOSITION TO GET TO VALVE.4. TROUBLE SHOOT BOTH REAR WORK LIGHTS INOP FOUND BAD GROUND, REQUIRED AND CLEAN GROUNDS.5. CHECK CONSOLE GUAGES, DO NOT HAVE LIGHTS.6. CHECK A/C CONTROL NOT HAVE LIGHTS.7. CHECK DRIVERS SEAT BELT, NO PROBLEM FOUND, LUBED.8. TIGHTEN ALL SCBA BRACKETS.9. ADJUST PUMP PANEL ACCESS DOORS, LOOSE.10. TROUBLE SHHOT FOAM AND OK TO PUMP LIGHTS INOP FOUND BAD CIRCUIT BOARD AND RELAY INSTALL NEW RELAY.11. AFTER REPLACING CIRCUT BOARD AND RELAY O.K TO PUMP AND FOAM WORKING INTERMITTENT.12. TROUBLESHOOT OK TO PUMP INTERMITTENT FOUND BAD CONNECTION ON FOAM OUMP SOLENOID.

1100467BOARD ELECTRICAL 1FS1022FILTER FUEL WIX 33422 PS8689 FRAM 1HPH6349AOIL FILTER 51748 1R90PFILTER FUEL 33231

Page 73: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V62359

Meter Reading:Close Date:

In Date: 11/30/201312/11/2013

1- request NY hook to be located on passenger side running board. 2- safety net needed for both preconnects. E22Problem?

Parts QuantityTask performed:

1. DRIVER COMPLAINT NY HOOK NEEDS TO BE MOUNTED, MOUNTED HOOK UNDER STEP.2. DRIVER COMPLAINT NO HOSE NETS ON CROSSLAY INSTALL CROSS LAY NETS.

25269LPVM-5 SM MOUNT

Workorder: V62490

Meter Reading:Close Date:

In Date: 12/04/201312/11/2013

new windshield wipers E22Problem?

Parts QuantityTask performed:

DRIVER COMPLAINT WIPERS BAD R&R WIPERS. 252-24WIPER BLADES ANCO 24

Workorder: V62366

Meter Reading:Close Date:

In Date: 12/01/201312/12/2013

need new lock and key for medical compartment E22Problem?

Parts QuantityTask performed:

1. TRAVEL TO 22 LATCH I HAVE NOT CORRECTED WILL RETURN PROPER LATCH.2. DRIVER COMPLAINT MED COMPARTMENT LATCH 10-7 REPLACED PULL LATCH.

124010-02DOOR HANDLE TRIMARK 1279LSS1250D-RING HANDLE W/LOCK 101280008

Workorder: V62728

Meter Reading:Close Date:

In Date: 12/15/201301/02/2014

air leaking only when appying pressure to brake pedal. E22Problem?

Parts QuantityTask performed:

TRAVEL TO 22 DRIVER COMPLAINT OF AIR LEAK REPLACED SWITCH IN DASH AND TESTER OK.

1FSC17491907NO SWITCH LOW AIR PRESSURE

Page 74: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V63190

Meter Reading:Close Date:

In Date: 90,173.9001/07/201401/07/2014

ON CALL CHECK ENG. LT ON RUNS POORLYProblem?

Parts QuantityTask performed:

WENT TO KEYLIME AND MANDRIN- FOUND ENG MISS AND SMOKING- FOUND 0277FUEL DIST SOLENOID AND OILL ECM CODES- FOLLOWED TO ST-22 WENT TO ST 21 FOR SPARE BATT ENG.

NO PARTS USED

Workorder: V63401

Meter Reading:Close Date:

In Date: 90,173.9001/15/201401/27/2014

Repair vent fanProblem?

Parts QuantityTask performed:

REMOVE MOTOR MOUNT FROM FRAME, STRAIGHTEN IN PRESS, WELD IN GUSET REPAINT REINSTALL IN FRAM INSTALLED ALL NEW MOTOR MOUNTS, CLEAN MOTOR TO REINSTALL IN FRAME, REPAIR BOTH WHEELS FALLING OFF RESHIN BOTH WHEELS REINSTALLED, TUNE UP MOTOR NO ROOM CHANGES OIL 1 QT RESTART AND RUN OK.

4FZ-K190-1MOTOR MOUNT RAM FAN GF165

Workorder: V63370

Meter Reading:Close Date:

In Date: 01/14/201401/31/2014

passenger side extenda light middle light bulb is out. e22Problem?

Parts QuantityTask performed:

DRIVER COMPLAINT LIGHT OUT REPLACED CONNECTION TO LIGHT.

NO PARTS USED

Workorder: V63792

Meter Reading:Close Date:

In Date: 01/28/201401/31/2014

base of the ground monitor safety trip switch is not locking open. appeared to be broken, will not reset. cannot use the ground monitor until its fixed. E22

Problem?

Parts QuantityTask performed:

CHECKED MONITOR WILL TRY TO FIND ONE AT SHOP TO REPLACE.

NO PARTS USED

Page 75: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V63160

Meter Reading:Close Date:

In Date: 90,173.9001/06/201402/04/2014

repair ecmProblem?

Parts QuantityTask performed:

REPAIR ECM. NO PARTS USED

Vendor?: CUMMINS

Workorder: V64006

Meter Reading:Close Date:

In Date: 02/05/201402/13/2014

we would like to get mount for the base of the deck gun in rear compartment and a mount for the axe on the D/O door...thanksProblem?

Parts QuantityTask performed:

TRAVEL TO 22 DELIVERED NEW MONITOR. NO PARTS USED

Workorder: V63609

Meter Reading:Close Date:

In Date: 01/22/201402/19/2014

2 lights not working. 1- rear tailboard spotlight on officer side 1- three lights over pump pannel, it the center spot light on officer side. e22

Problem?

Parts QuantityTask performed:

TRAVEL TO 22 DRIVER COMPLAINT LIGHTS OUT REPLACED BULBS IN BOTH LIGHTS FOUND SWITCH GOING BAD OK.

24007BULB NIGHT FIGHTER 2U-7421SWITCH - ROCKER FOR UNITY LIGHT

Workorder: V64247

Meter Reading:Close Date:

In Date: 02/15/201402/20/2014

Master intake value is not working and stuck in the closed position E22Problem?

Parts QuantityTask performed:

AIR LEAKS OARK BRAKE VALVE, REPLACED PARKING BRAKE VALVE.

NO PARTS USED

Page 76: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V64058

Meter Reading:Close Date:

In Date: 02/07/201402/21/2014

miv very difficult to open and close.Problem?

Parts QuantityTask performed:

MASTER INTAKE DIFFICULT TO OPEN WORKED AND LUBED MASTER INTAKE.

101893BULB 10194BULB

Workorder: V63127

Meter Reading:Close Date:

In Date: 01/04/201402/26/2014

front intake bleeder valve inoperable E22Problem?

Parts QuantityTask performed:

1. ALREADY REPAIRED.2. R&R WINDOW WONT ROLL UP, CAME OFF TRACK. REPAIRED R&R WINDOW TRACK.

134BVVALVE DRAIN CLASS1

Workorder: V63490

Meter Reading:Close Date:

In Date: 01/17/201402/26/2014

Mount for new york hook fell of needs to be fixed.Problem?

Parts QuantityTask performed:

NEW YORK HOOK MOUNT LOOSE, SCREWS MISSING. REPAIRED MOUNTING.

NO PARTS USED

Workorder: V64615

Meter Reading:Close Date:

In Date: 03/02/201403/05/2014

slide step tray, below drivers side door that holds batterys is sliding out while in motion. Lock mechanism is not operating appropriately. E22

Problem?

Parts QuantityTask performed:

PATIENT SLIDE OUT WONT LATCH MECHANISM FULL OF SAND CLEARED AND LUBED SLIDE OUT TRAY.

NO PARTS USED

Page 77: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V62631

Meter Reading:Close Date:

In Date: 12/10/201303/10/2014

Pressure relief valve not working properly. When pressure relef valve activates, pressure drops approximately 40 psi below desired pressure and remains at that pressure until handle is rotated several times. E22

Problem?

Parts QuantityTask performed:

1. DRIVER COMPLAINT PRESSURE RELIEF SLOW REPLACED RELIEF VALVE AND FILTER SYSTEM IS BETTER BUT NOT RIGHT.

1538-0201-02-0QG RELIEF VALVE COMPLETE 1538-1410-00VALVE SENSING SV HALE 1546126000TPM/QG HALE REPAIR KIT

Workorder: V64004

Meter Reading:Close Date:

In Date: 02/05/201403/10/2014

air leak on E22Problem?

Parts QuantityTask performed:

REPAIRED ON ANOTHER WO. 1800034VALVE PARKING BRK.

Workorder: V64263

Meter Reading:Close Date:

In Date: 02/16/201403/10/2014

E22 loses about 50% of its air in 12 hrs.found 2 air leaks under hood. E22 is still in use just takes a few mins for air tanks to fill.Problem?

Parts QuantityTask performed:

REPAIRED ON ANOTHER WO. NO PARTS USED

Workorder: V64343

Meter Reading:Close Date:

In Date: 02/19/201403/10/2014

Put this in last shift air leaking found 2 leaks causing a slower response to calls takes almost a minute to stop the low air alarm.Problem?

Parts QuantityTask performed:

AIR LEAKS, FITINGS IN DASH. REPLACED FITTINGS IN DASH.

NO PARTS USED

Page 78: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V64785

Meter Reading:Close Date:

In Date: 03/08/201403/12/2014

Tailboard upper left compartment (backboards) sensor head is sheared off. The sensor cannot activate to show the compartment door is closed, buzzing alarm constantly. Need a replacement for the door sensor. Thanks E22

Problem?

Parts QuantityTask performed:

L/R COMPARTMENT, SENSOR REPLACED DOOR SENSOR.

252-624SWITCH DOOR

Workorder: V64921

Meter Reading:Close Date:

In Date: 03/13/201403/17/2014

MIV red indicator light bulb missing, driver side step lights working intermitently, TIC not charging when placed in the mount.Problem?

Parts QuantityTask performed:

DRIVE FROM STA 30 TO STA 22 REPLACE LIGHT IN PUMP PANEL, REPAIR ALL ON LIST ABOVE.

NO PARTS USED

Workorder: V62976

Meter Reading:Close Date:

In Date: 12/27/201303/19/2014

SHORELINE PLUG FOR ENGINE CRUSHED. NEEDS TO BE REPLACED.Problem?

Parts QuantityTask performed:

forwareded to build maint NO PARTS USED

Workorder: V66389

Meter Reading:Close Date:

In Date: 05/11/201405/15/2014

generator crankcase is full of fuel. oil and gas mixed. E22Problem?

Parts QuantityTask performed:

TRAVEL TO 22 DRIVER COMPLAINT GENERATOR OIL CONTAMINATED. SERVICED GENERATOR.

NO PARTS USED

Page 79: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V66546

Meter Reading:Close Date:

In Date: 05/16/201405/21/2014

E22 needs all four new window frames secondary to rusting out. Water is coming into the cab of the truck. The truck sits outside with no cover over it.

Problem?

Parts QuantityTask performed:

TRAVEL TO 22 DRIVER COMPLAINT WATER COMING IN HEADLINER SCRAPPED OFF RUSTY WELD ON ROOF RESEALED WITH 5200 SEALANT.

16807200253GUIDE METAL 26807200353GUIDE METAL 36809870055SEAL CAB WINDOW

Workorder: V66248

Meter Reading:Close Date:

In Date: 05/05/201406/11/2014

ALL FOUR DOORS NEED WINDOW SURROUND REPLACED, RUSTED.Problem?

Parts QuantityTask performed:

Driver complaint window tracks rusted replaced 3 of 4 tracks and tested ok.

102036273300 TURBO94 CORNERLINEAR REFLECTOR

Workorder: V66585

Meter Reading:Close Date:

In Date: 05/19/201406/11/2014

FF window will not roll up or down.Problem?

Parts QuantityTask performed:

Driver complaint window inop R and R handle 123-12982-712COVER SCREW 1A1818557002HANDLE-WINDOW

Workorder: V66811

Meter Reading:Close Date:

In Date: 05/28/201406/11/2014

Spot light on top of cab will not turn. Top right front clearance lamp, rear work lamps(x 2), and top right rear flood lamp inop.Problem?

Parts QuantityTask performed:

Respond on ticket V66888. NO PARTS USED

Page 80: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V66888

Meter Reading:Close Date:

In Date: 05/31/201406/11/2014

spot light works, but bounces around inside bulb no movement control. E22Problem?

Parts QuantityTask performed:

Travel to 22. Driver complaint spot light broken replaced spot light and tested.

1620122SPOT LIGHT REMOTE

Workorder: V67309

Meter Reading:Close Date:

In Date: 06/18/201406/23/2014

Top Red driver side emergency light cover broken & the following emergency lights are not working: (Driver panel,Passenger side)(Rear,Driver side upper white light under step)(Rear,Passenger lower white light under step)

Problem?

Parts QuantityTask performed:

REPLACED LENS ON LEFT REAR UPPER ROTATOR REPLACED SWITCH AND REPAIRED MOUNT ON RIGHT REAR UPPER WORK LIGHT. CLEANED CONNECTIONS ON LEFT REAR UPPER WORK REPLACED BULB IN REAR STEP LIGHT.

11156BULB 2180R002HURST HYD. FLUID QT 1RB6DRPRB6PRP RED ROTATING BEACON 1U-7421SWITCH - ROCKER FOR UNITY LIGHT

Workorder: V67514

Meter Reading:Close Date:

In Date: 06/27/201407/02/2014

Front intake metal screen is missing.Problem?

Parts QuantityTask performed:

DRIVE COMPLAINT INTAKE SCREW MISSING R&R INTAKE SCREW.

1WAT61401STRAINER 4 IN

Workorder: V67959

Meter Reading:Close Date:

In Date: 07/16/201407/17/2014

CAB A/C ISN'T WORKING OR BLOWING ANY AIR AT ALL.Problem?

Parts QuantityTask performed:

Travel to staion 22, Driver complaint A/C inop. in cab. Replaced shorted A/C blow switch.

1ABPN8332229011-3050 SWITCH BLOWER

Page 81: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V68151

Meter Reading:Close Date:

In Date: 07/24/201407/31/2014

The power cord will not self eject when turning on the engineProblem?

Parts QuantityTask performed:

Driver complaint auto eject inop. Replaced auto eject. NO PARTS USED

Workorder: V68152

Meter Reading:Close Date:

In Date: 07/24/201407/31/2014

Pressure relief valve will not shut off once its activated and pressure drops approx 40 -50 psiProblem?

Parts QuantityTask performed:

Driver complaint relief valve slow. Ran pump and excercised relief valve after a few minutes, it worked great.

NO PARTS USED

Workorder: V68198

Meter Reading:Close Date:

In Date: 07/26/201407/31/2014

SERIAL NUMBER A66E612370626. MILUAKUEE SAW OUT OF SERVICE DUE TO BLADE BECOMING LOOSE AND DISLODGING WHILE OPERATION E22

Problem?

Parts QuantityTask performed:

Travel to 22. Told captain to send in saw with his d.c. for replacement.

NO PARTS USED

Workorder: V68545

Meter Reading:Close Date:

In Date: 08/09/201408/15/2014

intake gauge has a crack across it and is leaking oil. E22Problem?

Parts QuantityTask performed:

replaced intake pressure gauge. 191583956GAUGE 0-600 PSI 5 IN BLACK COMP

Page 82: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V68899

Meter Reading:Close Date:

In Date: 93,326.0008/24/201409/05/2014

air horn on e22 passemger side leaking air and weak sound. vent fan is working but the low oil cut off sensor is broken needs replaced.

Problem?

Parts QuantityTask performed:

1. Travel to 22 driver complaint air horn inoperable. Adjusted air horn.2. Driver coplaint ram fan switch bad. Ordered parts.

NO PARTS USED

Workorder: V69247

Meter Reading:Close Date:

In Date: 93,455.0009/09/201409/16/2014

miv valve is hard to turn.Problem?

Parts QuantityTask performed:

Miv gear box 10-7 will order parts. NO PARTS USED

Workorder: V69239

Meter Reading:Close Date:

In Date: 93,455.0009/08/201409/18/2014

front suction intake bleeder valve is missing handle.Problem?

Parts QuantityTask performed:

1. Travel to 22 , needs new valve going to shop for parts.2. Replaced bleeder valve.

134BVVALVE DRAIN CLASS1

Workorder: V68845

Meter Reading:Close Date:

In Date: 93,326.0008/21/201410/15/2014

B inspection E22 by OCSProblem?

Parts QuantityTask performed:

B inspection 1FS1022FILTER FUEL WIX 33422 PS8689 FRAM 1HPH6349AOIL FILTER 51748 1R90PFILTER FUEL 33231

Vendor?: OCS

Page 83: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V70211

Meter Reading:Close Date:

In Date: 10/16/201410/17/2014

E22 main radio knobs are falling off.Problem?

Parts QuantityTask performed:

forwareded to radio shop NO PARTS USED

Workorder: V69350

Meter Reading:Close Date:

In Date: 93,613.3009/13/201410/29/2014

The pressure relief valve not working properly. Once engaged it drops 40-60 psi and will not shut off... E22Problem?

Parts QuantityTask performed:

Replaced relief valve filters. 20100080010STRAINER

Workorder: V69668

Meter Reading:Close Date:

In Date: 93,945.4009/24/201410/29/2014

Master intake valve not openingProblem?

Parts QuantityTask performed:

Opened master intake and lubricated opens easier put still hard.

NO PARTS USED

Workorder: V69535

Meter Reading:Close Date:

In Date: 09/20/201411/03/2014

AIR LEAK E22Problem?

Parts QuantityTask performed:

Traced and repaired air leaks on engine. NO PARTS USED

Page 84: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V70708

Meter Reading:Close Date:

In Date: 94,478.0011/04/201411/07/2014

replaced RF tireProblem?

Parts QuantityTask performed:

WORK REPAIRS REQUESTED. NO PARTS USED

Vendor?: BLVD TIRE CENTER

Workorder: V70940

Meter Reading:Close Date:

In Date: 94,478.0011/14/201411/18/2014

cab a/c blower inopProblem?

Parts QuantityTask performed:

Diagnose blower inop-removed dash-found burnt wire as blower switch. Cut away melted terminal block and replaced wire terminal block and replaced wire terminal. Clean fan switch terminal, assemble fan switch plug and dash, test ok.

NO PARTS USED

Workorder: V71135

Meter Reading:Close Date:

In Date: 11/23/201412/02/2014

chain saw wont start... E22Problem?

Parts QuantityTask performed:

Travel to 22-checked saw found fuel line off and installed, ok.

NO PARTS USED

Workorder: V68992

Meter Reading:Close Date:

In Date: 08/27/201412/18/2014

sledgehammer handle cracked ,out of service need a new one.Problem?

Parts QuantityTask performed:

Goes through dis. chief-close ticket NO PARTS USED

Page 85: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V71844

Meter Reading:Close Date:

In Date: 12/24/201401/21/2015

light on the light bar is out. Unknown if work order has been placed already for this issue. ThanksProblem?

Parts QuantityTask performed:

Travel to ST 22. Replaced 2 strobes in light bar. NO PARTS USED

Workorder: V71209

Meter Reading:Close Date:

In Date: 11/26/201402/05/2015

1. main drain is leaking and was caped, also main drain valve unable to turn . 2. right intake valve is also leaking . E22Problem?

Parts QuantityTask performed:

1. Flushed intake relief valve to stop leak.2. Lubricated main pump drain.3. Rebuilt intake valve.

191388906 VALVE KIT 2.5 IN AKRON

Workorder: V71313

Meter Reading:Close Date:

In Date: 12/02/201402/10/2015

master intake is locked up unable to turnProblem?

Parts QuantityTask performed:

Travel to ST 22. Rebuild master intake. 10073250000GEARBOX ADAPTER 1037211000SHAFT MIV VLV 10401159000QUAD RING 20409160000O-RING 10410520000TRUNION MIV 1505-0230-00-0DICS 1512-0070-00-0MIV HANDLE 1531016000GEAR BOX MIV VALVE 1546-1620-02MASTER INTAKE KIT

Page 86: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V72368

Meter Reading:Close Date:

In Date: 01/15/201502/10/2015

air leak on e22, strobelight on light bar, intake on passenger side leaking.Problem?

Parts QuantityTask performed:

1. Repaired air leaks.2. Lights and intake repaired on previous tickets.

27ELTUBE7ELTUBE LINEAR STROBE REF

Workorder: V72967

Meter Reading:Close Date:

In Date: 02/08/201502/27/2015

E22 needs bar/chain oil for chainsaw.Problem?

Parts QuantityTask performed:

PARTS ONLY - Told crew to order from County shop. NO PARTS USED

Workorder: V73306

Meter Reading:Close Date:

In Date: 02/21/201502/27/2015

driver side low beam head light outProblem?

Parts QuantityTask performed:

1. Replaced headlight.2. Replaced switch for ft suction leaking air.

1H6054BLH6054CVC1 HEADLIGHT EXTRA BRIGHT 1MJTV5 VALVE AIR CONTROL

Workorder: V73347

Meter Reading:Close Date:

In Date: 02/23/201502/27/2015

One headlight is out on both our units Engine and Rescue. We have no spares to replace them. E22Problem?

Parts QuantityTask performed:

All repaired. NO PARTS USED

Page 87: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V73599

Meter Reading:Close Date:

In Date: 03/03/201504/01/2015

generator oil contaminated with gasoline.Problem?

Parts QuantityTask performed:

1. Seviced generator. NO PARTS USED

Workorder: V73600

Meter Reading:Close Date:

In Date: 03/03/201504/01/2015

Ram fan oil contaminated with gasoline.Problem?

Parts QuantityTask performed:

1. Travel to 22, replaced ram fan with space unit. NO PARTS USED

Workorder: V73631

Meter Reading:Close Date:

In Date: 03/04/201504/01/2015

vent fan out of service making noise. need a replacement E22Problem?

Parts QuantityTask performed:

1. Repalced fan with spare unit. NO PARTS USED

Workorder: V73632

Meter Reading:Close Date:

In Date: 03/04/201504/01/2015

hurst pump not running smooth pulses high and low. E22Problem?

Parts QuantityTask performed:

1. Cleaned carberator floot bowl. NO PARTS USED

Page 88: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V73369

Meter Reading:Close Date:

In Date: 02/23/201504/07/2015

fuel gauge on pump panel is broken, the front face has cracked off needs replaced.Problem?

Parts QuantityTask performed:

1. Replaced fule gauge. 1301-502301-104 FUEL GAUGE

Workorder: V73410

Meter Reading:Close Date:

In Date: 02/25/201504/07/2015

Bar handle on MIV broke off(captains side)Problem?

Parts QuantityTask performed:

1. Replaced master in take valve (MIT) handle. 1512-0070-00-0MIV HANDLE

Workorder: V73598

Meter Reading:Close Date:

In Date: 03/03/201504/07/2015

engine leaking coolant.Problem?

Parts QuantityTask performed:

1. Checked for coolant leak, none found. NO PARTS USED

Workorder: V73601

Meter Reading:Close Date:

In Date: 03/03/201504/07/2015

pump panel fuel gauge broken and fell behind pump panel.Problem?

Parts QuantityTask performed:

1. Travel to 22 Replaced pump panel fuole gauge. NO PARTS USED

Page 89: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V72557

Meter Reading:Close Date:

In Date: 01/23/201504/08/2015

2 Issues to report. 1st) The bar oil leaks right out of the chainsaw. 2nd) The Low oil kill switch sensor on the side of the crank case snapped off the vent fan.

Problem?

Parts QuantityTask performed:

1. Repaired small engines. NO PARTS USED

Workorder: V74681

Meter Reading:Close Date:

In Date: 04/15/201504/15/2015

shore line not working on engine . it keeps kicking breaker.Problem?

Parts QuantityTask performed:

CLOSED NEW WORK ORDER OPENED IN ASSET WORKS

NO PARTS USED

Page 90: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V73979

Meter Reading:Close Date:

In Date: 96,156.7003/18/201504/16/2015

C-inspectionProblem?

Parts QuantityTask performed:

Page 91: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

1. Began C inspection2. Replaced batteries [failed load test]3. Cleaned and lubricated battery box slides and latch assembly4. Replaced engine air filter5. Continued C inspection6. Continued C inspection7. Began repairing pipe fitting in tank for tank to pump valve. Had to remove a lot of parts to access. 8. Continued repairing water leak @ tank to pump valve. Had to remove left side air tank. Found numerous faulty air fittings. also found large wiring harness chaffed on frame rail bracket behind air tank9. Continued/ completed tank to pump fitting reseal. had to trim down pipes to facilitate tank to pump hose reinstall.Adjusted tank to pump linkage.10. Replaced all air hose fittings while tank was out. sanded and painted rusty spots on tank. Installed new primed pump and motor assembly.11. Installed ABS harness12. Reinstalled air tank. Connected all air lines and hoses. installed pet cock style drain valves in all tanks.13. Replaced both u-joints in rear shaft and installed.14. Serviced T-case15. Rebuilt air dryer. also protected discharge hose from rubbing leaf spring.16. Trans was overfull. Drained excess fluid.17. Trouble shot master intake valve indicator lights. Replaced all 3 indicator light assemblies. Removed valve assembly and split cases open. cleaned and lubed switches. Adjusted shaft stops and bench tested. Reinstalled ok18. Replaced gaskets on left and right steamer caps.19. Painted fuel cap. 20. Replaced wiper blades and cleaned debris from windshield squirters. Filled washer reservoir.21. Replaced left frount turn signal side marker light bulb22. Replaced step light bulbs in several locations. One step light lens and one light assembly23. Replaced rocker switch in cab for upper work light. Shorted out.24. Replaced rear a/c filter25. Made and installed max height sticker26. Replaced tri lock on tailboard27. Trouble shot right side pump panal lights. Inop. Traced problem to broken supply wire inside pump panal.28. Replaced broken reflectors on tailboard29. Replaced left rear lower marker light30. Replaced hold down straps on tailboard31. Replaced both cross ley nets worn out. 32. Fabricated new handle for deck gun33. Serviced power steering34. Trouble shot siren speaker inop. found corroded connection, speaker still inop. Replaced speaker and

20769027STRAINER 2.5 IN 3103385NDRAIN COCK 1107796DRYER KIT AD9 -NEW 1107800VALVE CHECK AD9 4108-12FBEADED CHAIN W/CONN 12 31141BULB 1120257100C2030-7110-30 CLEAR DOME STEP 1194BULB 12032-0000-30LENS CLEAR 135200-RLIGHT MARKER LED RED 1499583HOSE AND FITTING 1499679HOSE AND FITTNG 15-280XU-JOINT 15-675XU JOINT 1501-3090-00PRIMER PUMP MOTOR 252-24WIPER BLADES ANCO 24 152-624SWITCH DOOR 1546-00011-000HALE GREEN INDICATOR 1546-00011-001HALE RED INDICATOR LED 1546-2210-02-0LIGHT KIT HALE 26805450005RELAY NEW # POT-BFMA-15F41 178R536078R5360M 2PK FILTER AIR COND 1800405PURGE VALVE KIT 298032R 41032-3 RED REFLECTOR OVAL REFLECTOR 1A1512KNOB TFT REPLACEMENT 4BATTERY EPA TAXBATTERY EPA TAX $1.50 PER BATTERY 1CA8193AIR FILTER 46744 WIX 1FS1022FILTER FUEL WIX 33422 PS8689 FRAM 4HP-31DBATTERY 950CCA HP-31D 1HPH6349AOIL FILTER 51748 2MSA150-A18MANSAVER COVER 1R90PFILTER FUEL 33231 2REDG6S14023 GASKET 6 IN 1SD-210RSIREN DRIVER 1U-7421SWITCH - ROCKER FOR UNITY LIGHT 2UMVS111611STRAP 1UMVS162511STRAP 1UMVS254411STRAP 46 IN 1VML-S1414FILTER P/S 1VML-T1264GASKET P/S COVER 1VML-T1279WASHER P/S

Page 92: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

connections ok35. Replaced both small intake screens.36. Replaced man saver pads Removed old pads. Removed old glue. installed new pads. 37. Trouble shot door open alarm inop on right side of body. Traced problem to faulty relay in class one panel. Replaced relay ok38. Replaced door ajar switch on left rear door 39. Found and repaired numerous air leaks40. Repaired or replaced all discharge cap chains41. Repaired cab access cover behind drivers door. Drilled and tapped mounting holes and replaced screws42. Continued air leak repairs. repaired leaks under cab.43. Road tested truck and checked all repairs . Filled with water and checked for leaks. Also vacume tested truck.44. QA ok

Workorder: V74697

Meter Reading:Close Date:

In Date: 04/16/201504/16/2015

ticket in AW The hale foam system on the engine doesn't work, there is no power to the module on the pump panel.Problem?

Parts QuantityTask performed:

NO PARTS USED

Workorder: V74698

Meter Reading:Close Date:

In Date: 04/16/201504/17/2015

All 4 rear tires on the engine are worn down into the wear bars.Problem?

Parts QuantityTask performed:

tires not needed at this time NO PARTS USED

Page 93: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V73976

Meter Reading:Close Date:

In Date: 96,156.7003/18/201504/23/2015

BrakesProblem?

Parts QuantityTask performed:

1. Began replacing brakes, tors, caliper and seals on rear axle (broken rotor). Brakes, rotors on steer axle.2. Continued front and rear axle brake down. Removed broken and cracked rotors from hubs. Also replaced steer axle brake pads and hub caps (leaking). 3. Continued brake repairs, completed tear down. Cleaned all parts and began reassembly.4. Continued reassembly of brakes: reassembled hubs and rotors, brake calipers, cleaned and serviced slack adjusters Mounted hubs/rotors. Installed new ABS sensors. Installed calipers, installed axles.5. Continued/completed all brake repairs. Reinstalled brake chambers, sercured ABS sensors wires. Adjusted brakes. Have to wait for tire repairs before reinstalling wheels and tires.6. Trouble shoot cloolant leak on front of engine. Traced leak to faulty water pump. Replaced water pump. Filled with new coolant (had to change coolant drum in oil room).7. Replaced belts.8. Reinstalled all wheels and tires after tire guy. Repaired flat. Also reinstalled all hub caps.

105-17223-000CAP RADIATOR 10 LB 215016KIT15016 PIN KIT 23218K167ROTOR-BRAKE 2380003ASEAL 2401581GASKET AXLE FL80 R002435 140896474309418 PUMP-WATER ISC REBUILT 19440BELT 19480BELT 1A13263M1157CALIPER ASSY ENGREAR L/H 1A23263M1157CALIPER ASSY ENG REAR R/H 2CHR1612340-4024 HUB COVER - FRONT AXLE 2004 RESC 1K080716BELT 1KIT15625PMAXEL SET 1KIT195020PAD KIT FRONT FL80 PUMPER 1PR338324070 WIX FILTER WATER 2S4410325140R955342 SENSOR REAR ABS 4410328140

Workorder: V73938

Meter Reading:Close Date:

In Date: 96,156.7003/17/201504/27/2015

R/REAR FLAT TIRE & BRAKE DAMAGEProblem?

Parts QuantityTask performed:

Westway to tow to central shop from station.1. Drive to station, check unit, needs rear brakes and right rear inner tire.

NO PARTS USED

Vendor?: BOULEVARD

Page 94: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

12/17/2018

Palm Beach County Fire RescueFleet Maintenance Asset History

10142417* FIRE DEPARTMENT PUMPER NFPA COMPLIANT

Workorder: V73487

Meter Reading:Close Date:

In Date: 02/27/201504/29/2015

k12 vent saw gas cap is cracked and leaking fuel needs replaced.Problem?

Parts QuantityTask performed:

1. Had cab delivered to 22. 1506255903FUEL CAP K960 VENT SAW

Workorder: V73594

Meter Reading:Close Date:

In Date: 03/03/201506/30/2015

10187248 k12 oos fuel leaking out of fuel capProblem?

Parts QuantityTask performed:

NO PARTS USED

Page 95: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Palm Beach County Fire RescueFleet Maintenance Asset History

Asset: (10142417) 2001 - FERRARA FL80 1250 Gpm Pumper

10142417

CSHOP-2015-1056SPARE ENGINE AT 22 HOSEBED COVER IS TORN AND ROTTED FALLING APART.Comments:

97,1036-8-2015Date Finished: Meter 1 Reading:Date Opened 6-8-2015

TASKS PERFORMED Q PARTS

2 STRAINER; STRAINER 2.5 IN2 WIPER; WIPER BLADES ANCO 241 LIGHT; LIGHT ASSY. TURN SIGNAL

FIRE PUMPFIRE APPARATUSWIPER BLADESWIPERS-WASHERTURN SIGNAL LIGHTSAIR CONDITIONING

CSHOP-2015-1311K12 SHUTS OFF ON ITS OWN AND WHEN THROTTLE IS PUSHED / SPARK PUG CLEANED AND AIR FILTER APPEARS CLEAN

Comments:

97,1036-22-2015Date Finished: Meter 1 Reading:Date Opened 6-22-2015

TASKS PERFORMED NO PARTS USED

TRAVEL TO BE CHARGED TO WORK ORDERFIRE FIGHTING EQUIPMENT

CSHOP-2015-1519REAR ROTATING LT 10-7 E22 SPARE K12 SAW BOGS AND STALLS OUTComments:

97,1037-7-2015Date Finished: Meter 1 Reading:Date Opened 7-2-2015

TASKS PERFORMED NO PARTS USED

WAIT TIME TO BE CHARGED TO WORK ORDERTRAVEL TO BE CHARGED TO WORK ORDERFIRE FIGHTING EQUIPMENTLIGHTING SYSTEM

CSHOP-2015-1538AIR HORN BRACKET BROKEN E 22Comments:

97,1037-7-2015Date Finished: Meter 1 Reading:Date Opened 7-6-2015

TASKS PERFORMED Q PARTS

2 BRACKET; 244770R1 HORN SUPPORT BRKTTRAVEL TO BE CHARGED TO WORK ORDERAIR HORN

Page 96: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2015-1555E22 FOAM SYSTEM IS NOT WORKING, WON`T TURN ON WATER LEAK FROM PRIMER AREA PUMP PANEL LIGHTS DO NOT WORK

Comments:

98,93110-28-2015Date Finished: Meter 1 Reading:Date Opened 7-6-2015

TASKS PERFORMED Q PARTS

1 VALVE; CHECK VALVE 1/2 FOAMPRO1 CABLE; 4 PIN CABLE FLOW SENSOR HALE FOAM SYS.1 CABLE; CABLE 6 PIN HALE FOAM SYSTEM1 ASSEMBLY; HALE CAFTEC TRANSORB ASSY. FOAM SYS1 SOLENOID; SOLENOID INS CONT DUTY1 PUMP; PUMP HALE FOR FOAMMASTER1 VALVE; CHECK VALVE INJECTOR HALE FOAM SYS.1 SENSOR; SENSOR HALE HPF FOAM FLOW-1 VALVE; CHECK VALVE INJECTOR HALE FOAM SYS.1 CONTROL; FM CONTROL UNIT RETROFIT KIT1 PUMP; DISTRIBUTION BOX1 MOTOR; 108494-00 MOTOR ELECT HALE FOAM PUMP1 MOTOR; 108494-00 MOTOR ELECT HALE FOAM PUMP1 SOLENOID; 2000072100 SOLENOID HALE PRIMER

WAIT TIME TO BE CHARGED TO WORK ORDERTRAVEL TO BE CHARGED TO WORK ORDERFOAM SYSTEMPRIMING PUMP FIRE PUMP

CSHOP-2015-2978E22 AIR RIDE SYSTEM LEAKINGComments:

98,71010-15-2015Date Finished: Meter 1 Reading:Date Opened 9-18-2015

TASKS PERFORMED Q PARTS

2 FREIGHTLINER; CAB AIR BAG IS4007WAIT TIME TO BE CHARGED TO WORK ORDERTRAVEL TO BE CHARGED TO WORK ORDERCAB

Service Requests:

09/18/2015 AIR RIDE / 18: LEAKING / EXCHANGE - NEWAIR SYSTEM LEAKING . FAST LEAK.

CSHOP-2015-3076 98,70010-7-2015Date Finished: Meter 1 Reading:Date Opened 9-24-2015

TASKS PERFORMED Q PARTS

1 SWIVEL; BD55015-1616-01 SWIVELTRAVEL TO BE CHARGED TO WORK ORDERHOSE REEL

Service Requests:

09/24/2015 SERVICE REQUEST / 18: LEAKING / EXCHANGE - NEWHOSE REEL ELBOW LEAKING

Page 97: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2015-3237RT REAR DISCHARGE LEAKS E 22Comments:

98,71010-7-2015Date Finished: Meter 1 Reading:Date Opened 10-5-2015

TASKS PERFORMED NO PARTS USED

FIRE PUMP

Service Requests:

10/03/2015 SERVICE REQUEST / 18: LEAKING / ADJUSTRIGHT REAR DISCHARGE LEAKING.

CSHOP-2015-3594E22Comments:

98,93111-3-2015Date Finished: Meter 1 Reading:Date Opened 10-26-2015

TASKS PERFORMED NO PARTS USED

HEADLIGHTS LOW BEAM

Service Requests:

10/26/2015 LIGHTS / 12: BROKEN / EXCHANGE - REBUILTPASSENGER SIDE HEAD LIGHT OUT

10/26/2015 LIGHTS / 12: BROKEN / EXCHANGE - NEWPASSENGER SIDE REAR STROBE ON LIGHT BAR NOT WORKING

10/26/2015 LIGHTS / 12: BROKEN / EXCHANGE - NEWRIGHT SIDE PUMP PANEL LIGHT NOT WORKING

CSHOP-2015-3718B940 WILL NOT STARTComments:

98,93111-3-2015Date Finished: Meter 1 Reading:Date Opened 11-2-2015

TASKS PERFORMED NO PARTS USED

TRAVEL TO BE CHARGED TO WORK ORDERFOAM SYSTEM

Service Requests:

10/31/2015 SERVICE REQUEST / 12: BROKEN / INSPECTON BOARD HALE FOAM SYSTEM STOPPED OPERATING DURING AN INCIDENT. AT APPROX 40 % OF FOAM LEFT, THE

ELECTRONIC PANEL READ AND FLASHED "FLUSH". AT THIS POINT FOAM SYSTEM WAS INOPERABLE. APPROX 10

MINUTES LATER, OPERATIONS WERE CONTINUED AND THE ON BOARD FOAM SYSTEM WAS FUNCTIONING

CORRECTLY WITHOUT INCIDENT. ON BOARD FOAM SYSTEM HAD JUST BEEN FIXED AND BECAME OPERABLE LAST

SHIFT. PLEASE COME AND CHECK FOR ANY POTENTIAL ISSUE.

Page 98: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2015-4074E22 PPV FAN WONT STAY RUNNING...Comments:

99,56612-16-2015Date Finished: Meter 1 Reading:Date Opened 11-20-2015

TASKS PERFORMED NO PARTS USED

TRAVEL TO BE CHARGED TO WORK ORDERFIRE FIGHTING EQUIPMENTAIR SYSTEM

Service Requests:

11/23/2015 AIR RIDE / 18: LEAKING / REPLACED LEAKING FITTINGAIR SYSTEM LEAK. LEAKS DOWN FAST. WHEN UNIT IS OFF.

11/19/2015 SERVICE REQUEST / 43: WEAK / INSPECTTHE K12 ON ENGINE 22 WILL NOT IDLE AND BOGS DOWN WHEN YOU SQUEEZE THE THROTTLE.

CSHOP-2015-435P.O. NUMBER 042315-15436Comments:

97,0025-4-2015Date Finished: Meter 1 Reading:Date Opened 5-4-2015

TASKS PERFORMED NO PARTS USED

REAR TIRES

VENDOR? EARL COLVARD BOULEVARD TIRE

CSHOP-2015-4429E22Comments:

99,56612-16-2015Date Finished: Meter 1 Reading:Date Opened 12-11-2015

TASKS PERFORMED Q PARTS

1 BELT; SEAT BELT OLD IMMF118481 GAUGE; TRANS TEMP GAUGE1 FILTER; AIR FILTER CUTTERS EDGE

WINDOW CHANNELSEAT BELTSINSTRUMENTS-GAUGES-WARNING &

Service Requests:

12/10/2015 HAZARD / 44: WORN / REPLACED BOTH REAR SEAT BELTSBOTH REAR SEATBELT NOT RETRACTING FULLY.

12/10/2015 BODY / 44: WORN / INSPECTED WINDOWSALL THE WINDOW SEAL LEAK VERY BAD WHEN IT RAINS

12/10/2015 TEMPERATURE / 12: BROKEN / REPLACED BROKEN TRANS TEMP GAUGEGAUGE FELL THROUGH ON PUMP PANEL

CSHOP-2015-62B14Comments:

97,0024-30-2015Date Finished: Meter 1 Reading:Date Opened 4-15-2015

TASKS PERFORMED NO PARTS USED

TRAVEL TO BE CHARGED TO WORK ORDERELECTRICALTIRES & WHEELS

Page 99: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2015-664E22 STALLED AND WON`T RESTARTComments:

97,0025-19-2015Date Finished: Meter 1 Reading:Date Opened 5-15-2015

TASKS PERFORMED NO PARTS USED

TRAVEL TO BE CHARGED TO WORK ORDERENGINE AND ACCESSORIES

CSHOP-2015-77HALE FOAM SYSTEM INOPComments:

97,0024-16-2015Date Finished: Meter 1 Reading:Date Opened 4-16-2015

TASKS PERFORMED NO PARTS USED

DIAGNOSE ELECTRICAL

CSHOP-2016-1018C INSPECTION E22Comments:

101,0863-4-2016Date Finished: Meter 1 Reading:Date Opened 3-3-2016

TASKS PERFORMED Q PARTS

24 FLUID; SYN OIL BULK QTS1 FILTER; OIL FILTER 517481 FILTER; FILTER FUEL WIX 33422 PS8689 FRAM1 FILTER; FILTER FUEL 33231

PM SERVICE C

Page 100: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2016-1053E22 REPAIRS FROM PMComments:

101,0943-23-2016Date Finished: Meter 1 Reading:Date Opened 3-7-2016

TASKS PERFORMED Q PARTS

1 NEWPART; HOSE & FITTING1 VALVE; 8907 VALVE KIT 3 IN AKRON1 FLAP; FLAPPER KIT1 FLANGE; FLANGE4 GASKET; GASKET2 SWITCH; SWITCH COVER1 CHAIN; BEADED CHAIN W/CONN 121 STEP; 2030-7110-30 CLEAR DOME STEP1 COVER; MANSAVER COVER1 LATCH; DRAWER LATCH ASSY RIGHT18 DECAL; LADDER OUT OF SERVICE STICKER2 WIPER; WIPER BLADES ANCO 242 CLAMP; CLAMP 4"" 339691 NEWPART; CLAMP1 SWITCH; 55014 SWITCH1 PIPE; EXH PIPE1 HOSE; 3286499 HOSE OIL RETURN1 GASKET; DRAIN GASKET 39377062 STRAINER; STRAINER 2.5 IN1 LIGHT; LIGHT MARKER LED RED1 LIGHT; LIGHT MARKER LEDAMBER1 LIGHT; LIGHT MARKER LEDAMBER2 BULB; BULB3 BULB; BULB1 BULB; BULB 12 VOLT2 BELT; SEAT BELTS1 VALVE; VALVE CORE1 STUD; STUD1 MERITOR; GREASE ROCKWELL A-1779-W-2831 SEAL; SEAL1 GASKET; GASKET AXLE FL80 R0024351 BRAKE; ROTOR-BRAKE1 VALVE; VALVE CHECK AD91 DRYER; DRYER KIT AD9 -NEW1 VALVE; PURGE VALVE KIT1 LIGHT; MAP LIGHT LED 18 IN1 SEAL; SEAL DOOR1 FILTER; 78R5360M 2PK FILTER AIR COND1 FILTER; 24070 WIX FILTER WATER

FOAM SYSTEMTANK SUCTION VALVE FIRE PUMPPUMP PANELGEAR BOX FIRE PUMPEQUIPMENT MOUNTING BRACKETSUNDERBODY COMPARTMENT BODYLADDER RACK BODYHINGED DOOR BODYWIPER BLADESEXHAUST PIPECOOLING SYSTEMOIL FILTER HOUSINGSPOT LIGHTSPARK-CLEARANCE LIGHTSLIGHTING SYSTEMSWITCH-ELECTRICALREAR TIRESROTORS REARAIR DRIERAIR SYSTEMSTROBE LIGHTSSAFTEY-EMERGENCY EQUIPMENTDOOR WEATHER MOLDINGSEAT BELTSA/C FILTER SCREENSAIR CONDITIONING

Page 101: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2016-1392QUALITY CHECKComments:

101,0863-24-2016Date Finished: Meter 1 Reading:Date Opened 3-23-2016

TASKS PERFORMED Q PARTS

1 PUMP; PISTON1 ORING; ORING KIT1 SPRING; SPRING PRIMER1 GASKET; FUEL SENDER GASKET M21 FREIGHTLINER; FUEL SENDING UNIT

PRIMING PUMP FIRE PUMPFUEL TANKQUALITY CHECK-REPAIRS

CSHOP-2016-1441 101,1284-5-2016Date Finished: Meter 1 Reading:Date Opened 3-28-2016

TASKS PERFORMED NO PARTS USED

TRAVEL TO BE CHARGED TO WORK ORDERFIRE FIGHTING EQUIPMENTREAR TIRES

Service Requests:

03/23/2016 SERVICE REQUEST / 12: BROKEN / INSPECTTHE K12 SAW ON E22 NEEDS WORK. SAW WILL NOT IDLE AND THROTTLE STICKS AT FULL RPM. ONLY WAY TO BRING

SAW BACK DOWN TO IDLE IS TO ACTIVATE THE KILL SWITCH.

CSHOP-2016-1638INSTALL LED HEADLIGHTSComments:

101,1284-7-2016Date Finished: Meter 1 Reading:Date Opened 4-6-2016

TASKS PERFORMED Q PARTS

2 NEWPART; 5 X 7 LED HEADLIGHTTRAVEL TO BE CHARGED TO WORK ORDERHEADLIGHTS LOW BEAM

CSHOP-2016-1680 101,1284-11-2016Date Finished: Meter 1 Reading:Date Opened 4-11-2016

TASKS PERFORMED NO PARTS USED

TRAVEL TO BE CHARGED TO WORK ORDERFIRE FIGHTING EQUIPMENT

Service Requests:

04/09/2016 FUEL / 15: FOREIGN MATERIAL / EXCHANGE - NEWFUEL IN THE OIL . IN THE GENERATOR ON E22

Page 102: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2016-1762E22Comments:

101,1284-15-2016Date Finished: Meter 1 Reading:Date Opened 4-14-2016

TASKS PERFORMED Q PARTS

1 INSERT; LARGE PLACARD INSERT CARDTRAVEL TO BE CHARGED TO WORK ORDERREPAIR FROM PM - DECALS/CLEANLINESS

Service Requests:

04/14/2016 DECALS / 41: TORN/PUNCTURED / EXCHANGE - NEWSTICKER ON THE PLACARD WITH STATION NUMBER ON OFFICERS SIDE HAS PEELED OFF AND NEEDS TO BE

REPLACED.

CSHOP-2016-2077E22Comments:

101,4785-3-2016Date Finished: Meter 1 Reading:Date Opened 5-2-2016

TASKS PERFORMED Q PARTS

1 BELT; SEAT BELT P/STRAVEL TO BE CHARGED TO WORK ORDERDOORSEAT BELTS

Service Requests:

04/29/2016 OTHER / 12: BROKEN / EXCHANGE - NEWTHE SEATBELT BUCKLE HOUSING IS BROKEN NEAR THE RED EJECT BUTTON ON THE FRONT PASSENGER SIDE.

04/29/2016 ELECTRICAL / 21: MISADJUSTED / ADJUSTTHE "OPEN DOOR" BUZZER GOES OFF INTERMITTENTLY FOR NO REASON AND WILL STAY ON FOR SEVERAL

MINUTES

CSHOP-2016-2093ON CALL E22 PRIMERComments:

101,5485-4-2016Date Finished: Meter 1 Reading:Date Opened 5-2-2016

TASKS PERFORMED Q PARTS

1 PUMP; PRIMER PUMP MOTORPRIMING PUMP FIRE PUMP

CSHOP-2016-2539E22Comments:

101,9115-26-2016Date Finished: Meter 1 Reading:Date Opened 5-26-2016

TASKS PERFORMED NO PARTS USED

TRAVEL TO BE CHARGED TO WORK ORDERFIRE PUMP

Service Requests:

05/26/2016 SERVICE REQUEST / 12: BROKEN / REPAIRPRIMER NOT WORKING

Page 103: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2016-2661E22Comments:

101,9116-6-2016Date Finished: Meter 1 Reading:Date Opened 6-3-2016

TASKS PERFORMED NO PARTS USED

TRAVEL TO BE CHARGED TO WORK ORDERFIRE FIGHTING EQUIPMENT

Service Requests:

06/02/2016 OTHER / 15: FOREIGN MATERIAL / REPAIRK12 VENT SAW ONLY RUNS ON CHOKE IF TAKEN OFF CHOKE ENGINE RUNS OUT OF CONTROL TO AN EXTREMELY

HIGH RPM .

CSHOP-2016-2847E22Comments:

102,4127-12-2016Date Finished: Meter 1 Reading:Date Opened 6-14-2016

TASKS PERFORMED Q PARTS

1 VALVE; PMD CONTROL VALVETRAVEL TO BE CHARGED TO WORK ORDERRELIEF VALVE FIRE PUMPSPOT LIGHTS

Service Requests:

06/14/2016 LIGHTS / 12: BROKEN / REPAIRTELE LIGHT ON PASSENGER SIDE NOT WORKING NO POWER TO ALL 3 LIGHTS.

06/19/2016 SERVICE REQUEST / 15: FOREIGN MATERIAL / REPAIRPRESSURE RELIEF VALVE IS NOT OPERATING PROPERLY. FOR EXAMPLE: RELIEF VALVE SET FOR 150PSI, INSTEAD

OF MAINTAINING PRESSURE AT 150 PRESSURE WILL DROP TO 90, AND TAKES APPROXIMATELY 60-90 SECONDS TO

RELEASE WHEN ADJUSTMENTS ARE MADE. FOUND BAD SCREEN IN PUMP BLOCKING WATER FLO TO ALL VALUES

CLEAN AND REPAIR RECHECK SYSTEM RESPONDING AT THIS TIME LIGHT GOING ON AND OFF WITH RE CERT

VALUE.

CSHOP-2016-340E-22 AIR LEAK BOTH TANKS EMPTY WITH IN 6 HOURSComments:

100,9163-2-2016Date Finished: Meter 1 Reading:Date Opened 1-25-2016

TASKS PERFORMED NO PARTS USED

WAIT TIME TO BE CHARGED TO WORK ORDERTRAVEL TO BE CHARGED TO WORK ORDERAIR CONDITIONING

Service Requests:

01/24/2016 AIR RIDE / 18: LEAKING / AIR LEAKRAPID AIR LEAK, BOTH AIR TANKS EMPTY WITHIN 6 HOURS

Page 104: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2016-3709E22 MDC POWERComments:

102,8818-6-2016Date Finished: Meter 1 Reading:Date Opened 8-1-2016

TASKS PERFORMED NO PARTS USED

DIAGNOSE ELECTRICAL

Service Requests:

08/01/2016 SERVICE REQUEST / 19: LOOSE / REPAIRE22 MDC KEEPS LOSING POWER. HAPPENED OVER THE WEEKEND, THEY JIGGLED WIRES AND IT CAME BACK ON.

HAPPENED AGAIN TODAY. SEEMS TO BE A PERSISTENT ISSUE. PLEASE TAKE A LOOK. THANKS IN ADVANCE AND

HAPPY MONDAY!

CSHOP-2016-3976E22Comments:

103,6829-28-2016Date Finished: Meter 1 Reading:Date Opened 8-12-2016

TASKS PERFORMED NO PARTS USED

TRAVEL TO BE CHARGED TO WORK ORDERSPOT LIGHTSFRONT TIRESAIR SYSTEM

Service Requests:

08/11/2016 LIGHTS / 12: BROKEN / LIGHT PLUG MELTEDTELESCOPE LIGHT ON E22 ON CAPT SIDE QUIT WORKING. THE POWER WENT OFF TO ALL 3 LIGHTS WHEN

LOWERING LIGHT .THE LIGHT IS THE 3 SEPARATE ROUND HALOGEN BULBS.

08/18/2016 SERVICE REQUEST / 18: LEAKING / REPLACED AIR FITTINGS ON FRONT TANKMAJOR AIR LEAK TELESCOPIC LIGHT ON CAPTAINS SIDE NOT WORKING

CSHOP-2016-4952 104,06710-18-2016Date Finished: Meter 1 Reading:Date Opened 10-17-2016

TASKS PERFORMED NO PARTS USED

TRAVEL TO BE CHARGED TO WORK ORDERFIRE FIGHTING EQUIPMENT

Service Requests:

10/17/2016 SERVICE REQUEST / 12: BROKEN / EXCHANGE - NEWSERVICE REQUEST ATTEMPTED START OF K-12. ONLY TURNED OVER 3 TIMES FOR APPROX 2 SEC EACH TIME. AFTER

TRYING TO ADJUST THE CHOKE, IT STILL WOULD NOT START. LET IT SIT IN CASE IT WAS FLOODED, STILL NO START

OR TURNOVER.

Page 105: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2016-5112 104,48011-10-2016Date Finished: Meter 1 Reading:Date Opened 10-27-2016

TASKS PERFORMED Q PARTS

1 GROMMET; HONDA FUEL GROMET1 PLUG; SPARK PLUG 7734

FIRE FIGHTING EQUIPMENT

Service Requests:

10/26/2016 SERVICE REQUEST / 15: FOREIGN MATERIAL / REPAIRSERVICE REQUEST, GAS FAN NOT RUNNING RIGHT STALLS OUT ONCE STARTED .

10/27/2016 HAZARD / 12: BROKEN / REPAIRFOAM SYSTEM NOT WORKING FLASHING FLUSH.

CSHOP-2016-5566 105,2971-3-2017Date Finished: Meter 1 Reading:Date Opened 11-29-2016

TASKS PERFORMED Q PARTS

1 9IP; 9IP1 9IP; 9IP

TRAVEL TO BE CHARGED TO WORK ORDERFIRE FIGHTING EQUIPMENTAIR SYSTEMHOOD

Service Requests:

11/26/2016 OTHER / 32: POROSITY / REPAIRK12 NOT IDLING , AND RUNNING ROUGH.

CSHOP-2016-5654 104,87712-19-2016Date Finished: Meter 1 Reading:Date Opened 12-5-2016

TASKS PERFORMED Q PARTS

1 CUMMINS; 4940575 HEAD CORROSION RESISTER1 FILTER; 24070 WIX FILTER WATER1 VALVE; SHAFT SHUT-OFF VALVE1 VALVE; SHAFT SHUT-OFF VALVE1 VALVE; 4940547 SHAFT SHUT-OFF VALVE1 VALVE; 4940547 SHAFT SHUT-OFF VALVE1 VALVE; SCREW SHUTOFF VALVE1 VALVE; SCREW SHUTOFF VALVE2 ORING; O-RING WATER SHUT OFF2 ORING; O-RING WATER SHUT OFF2 VALVE; O-RING SHUT-OFF VALVE2 VALVE; O-RING SHUT-OFF VALVE1 GASKET; GASKET 49428741 GASKET; GASKET 494287412 FLUID; SYN OIL QT6 FLUID; 50-50 EXTENDED LIFE COOLANT GAL

WAIT TIME TO BE CHARGED TO WORK ORDERTRAVEL TO BE CHARGED TO WORK ORDERFOAM SYSTEMCOOLING SYSTEMLIGHTING SYSTEMFLUID

Service Requests:

12/03/2016 SERVICE REQUEST / 12: BROKEN / EXCHANGE - USED

Page 106: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2016-651INSTALL NEW COUPLINGS FOR HURST UNITComments:

100,6262-9-2016Date Finished: Meter 1 Reading:Date Opened 2-9-2016

TASKS PERFORMED Q PARTS

2 FLUID; HURST HYD. FLUID QT2 HOSE; HURST HOSE W/O SWIVEL

FIRE FIGHTING EQUIPMENT

CSHOP-2016-738B22Comments:

100,9162-16-2016Date Finished: Meter 1 Reading:Date Opened 2-16-2016

TASKS PERFORMED NO PARTS USED

TRAVEL TO BE CHARGED TO WORK ORDERPRIMING PUMP FIRE PUMP

Service Requests:

02/13/2016 SERVICE REQUEST / 15: FOREIGN MATERIAL / FLUSHED PRIMER RUNS FINE.PRIMER IS NOT OPERATING PROPERLY

CSHOP-2016-92E22 HAND LIGHT CHARGING BASE IS BROKENComments:

100,2141-12-2016Date Finished: Meter 1 Reading:Date Opened 1-7-2016

TASKS PERFORMED NO PARTS USED

TRAVEL TO BE CHARGED TO WORK ORDERSPOT LIGHTS

Service Requests:

01/07/2016 LIGHTS / 12: BROKEN / REPLACED HAND LIGHT BASEHAND LIGHT CHARGING BASE IS BROKEN ON THE SIDE OF FIREFIGHTER SEAT.

CSHOP-2017-1435E22Comments:

106,4033-29-2017Date Finished: Meter 1 Reading:Date Opened 3-8-2017

TASKS PERFORMED Q PARTS

2 9IP; LG MOUNTTRAVEL TO BE CHARGED TO WORK ORDEREQUIPMENT MOUNTING BRACKETSDOOR

Service Requests:

03/08/2017 ALARMS / 49: CAN NOT DUPLICATE CONCERN / INSPECTALARM SIGNALS, BUZZER FOR DOOR ALARM IS GOING OFF RANDOMLY.

Page 107: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2017-2154 106,8474-13-2017Date Finished: Meter 1 Reading:Date Opened 4-13-2017

TASKS PERFORMED NO PARTS USED

RELIEF VALVE

Service Requests:

04/13/2017 SHOP / 11: BINDS/STICKS / LUBRICATETHE PRESSURE RELIEF VALVE IS HARD TO TURN.

CSHOP-2017-2871 107,2845-18-2017Date Finished: Meter 1 Reading:Date Opened 5-15-2017

TASKS PERFORMED Q PARTS

1 MBI; PRESSURE PROTECT VLVTRAVEL TO BE CHARGED TO WORK ORDERAIR HORN

CSHOP-2017-2968 107,5285-31-2017Date Finished: Meter 1 Reading:Date Opened 5-19-2017

TASKS PERFORMED Q PARTS

2 NGK; SPARK PLUGTRAVEL TO BE CHARGED TO WORK ORDERFIRE FIGHTING EQUIPMENTCAB

Service Requests:

05/18/2017 BODY / 35: RUSTED/CORRODED / INSPECTBODY ISSUE, WATER LEAKING INSIDE THE CAB OF THE TRUCK.

05/20/2017 SERVICE REQUEST / 12: BROKEN / REPAIRSERVICE REQUEST K-12 SAW HIGH IDLE POST CHOKE AND LOW IDLE AND SHUT OFF POST THROTTLE PULL.

CSHOP-2017-299SPARE ENGINE AT 22 LIGHTS NOT WORKING AND NOZZLE HARD TO WORKComments:

105,5481-20-2017Date Finished: Meter 1 Reading:Date Opened 1-13-2017

TASKS PERFORMED Q PARTS

1 9IP; 9IPTRAVEL TO BE CHARGED TO WORK ORDERFIRE FIGHTING EQUIPMENTLIGHTING SYSTEM

Service Requests:

01/13/2017 LIGHTS / 12: BROKEN / EXCHANGE - NEWVEHICLE LIGHTS NOT WORKING- THE DRIVER REAR LIGHT ( NOT THE BRAKE LIGHT - CIRCULAR WHITE LIGHT ) DOES

NOT ILLUMINATE. THE "OK TO PUMP " LIGHT ON THE PUMP PANEL DOES NOT ILLUMINATE. ( THE " OK TO PUMP IN THE

TRUCK IS WORKING )

01/13/2017 SERVICE REQUEST / 49: CAN NOT DUPLICATE CONCERN / INSPECTORANGE NOZZLE IS DIFFICULT TO OPERATE- NEED A REPLACEMENT PLEASE. NO ASSET ON NOZZLE- THE NUMBER

IS TFTH-358840

Page 108: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2017-3266 107,5286-5-2017Date Finished: Meter 1 Reading:Date Opened 6-5-2017

TASKS PERFORMED NO PARTS USED

TRAVEL TO BE CHARGED TO WORK ORDERFIRE APPARATUSOIL

Service Requests:

06/04/2017 SERVICE REQUEST / 20: LUBE/OIL SOAKED / INSPECTSERVICE REQUEST ENGINE OIL IS ABOVE THE MAX INDICATOR LINE.

CSHOP-2017-3345 107,6816-7-2017Date Finished: Meter 1 Reading:Date Opened 6-6-2017

TASKS PERFORMED NO PARTS USED

LIGHTING SYSTEM

Service Requests:

06/06/2017 SERVICE REQUEST / 49: CAN NOT DUPLICATE CONCERN / INSPECTSERVICE REQUEST -CHARGER FOR LIGHT BOX INOP OFFICER SIDE REAR

CSHOP-2017-3426 107,6816-12-2017Date Finished: Meter 1 Reading:Date Opened 6-9-2017

TASKS PERFORMED NO PARTS USED

TRAVEL TO BE CHARGED TO WORK ORDERHANDLIGHT

Service Requests:

06/09/2017 SERVICE REQUEST / 49: CAN NOT DUPLICATE CONCERN / INSPECTCHARGER ON E22 REAR OFFICER SIDE BROKEN

CSHOP-2017-3478 107,8436-21-2017Date Finished: Meter 1 Reading:Date Opened 6-12-2017

TASKS PERFORMED NO PARTS USED

TRAVEL TO BE CHARGED TO WORK ORDERAIR SYSTEM

Service Requests:

06/12/2017 BRAKES / 49: CAN NOT DUPLICATE CONCERN / INSPECTAIR PRESSURE IN THE TRUCK IS GOING DOWN TO ABOUT 100PSI EVERYTIME THE BRAKES ARE PUSHED. WHILE

DRIVING THE AIR PRESSURE BUILDS TO JUST UNDER THE LINE. THE LOW AIR PRESSURE ALARM IS GOING OFF

CONTINUOUSLY.

Page 109: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2017-4222LOW VOLTAGE LIGHT AND ALARMComments:

107,9267-26-2017Date Finished: Meter 1 Reading:Date Opened 7-19-2017

CHECKED ALTERNATOR

TASKS PERFORMED Q PARTS

1 5GI; BATTERY POST FEMALE-4 1AD; BATTERY 31 SERIES4 1AD; BATTERY 31 SERIES4 1AD; BATTERY 31 SERIES1 ECH; MAS DISCONNECT SWITCH-1 ECH; MAS DISCONNECT SWITCH1 9AP; HAND SOAP PUMICIZED1 9IP; 320 UPGRADE ALTERNATOR

ECU-ECMBATTERYCRANKING SYSTEMALTERNATOR-GENERATOR

CSHOP-2017-4570 107,9468-9-2017Date Finished: Meter 1 Reading:Date Opened 8-7-2017

WON`T PUMP

TASKS PERFORMED Q PARTS

1 9IP; BREAKER 30 AMPFIRE PUMP

CSHOP-2017-473ENGINE AT 22 LOUD AIR LEAK AND BRAKE PEDAL WHEN APPLYING BRAKESComments:

105,7241-26-2017Date Finished: Meter 1 Reading:Date Opened 1-23-2017

TASKS PERFORMED Q PARTS

1 2FL; NORM CLSD 2 WIRE PRES SWAIR SYSTEM

Service Requests:

01/22/2017 BRAKES / 18: LEAKING / EXCHANGE - NEWLOUD AIR LEAK AT THE BRAKE PEDAL WHEN YOU APPLY THE BRAKES

CSHOP-2017-5028PRE-TRIP INSPECTIONComments:

107,9468-31-2017Date Finished: Meter 1 Reading:Date Opened 8-26-2017

TASKS PERFORMED NO PARTS USED

SMALL ENGINE REPAIRPRE TRIP INSPECTION

Page 110: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2017-555 105,7242-1-2017Date Finished: Meter 1 Reading:Date Opened 1-25-2017

TASKS PERFORMED NO PARTS USED

TRAVEL TO BE CHARGED TO WORK ORDERFIRE FIGHTING EQUIPMENT

Service Requests:

01/13/2017 SERVICE REQUEST / 15: FOREIGN MATERIAL / EXCHANGE - USEDSERVICE REQUEST FOR K-12 ON E22. THE SAW STALLS INTERMITTENTLY.

CSHOP-2017-6143 107,95210-28-2017Date Finished: Meter 1 Reading:Date Opened 10-24-2017

TASKS PERFORMED Q PARTS

1 FIL; FUEL WATER SEPARATOR1 FIL; NAPAGOLD OIL FILTER1 FIL; NAPAGOLD FUEL FILTER

PM SERVICE B

CSHOP-2017-6213PM FOLLOW UPS SEE "RELATED FILES"Comments:

107,96511-3-2017Date Finished: Meter 1 Reading:Date Opened 10-28-2017

TASKS PERFORMED Q PARTS

1 9HY; HOSE MADE1 9IP; 546-3240-00-0 FOAM PUMP SENSOR KIT1 TWD; BENDIX3 9XX; AC FREON 101746762 1AN; WIPER BLADE 24 IN

FREON REORDERFOAM SYSTEMFIRE PUMPWIPER BLADESLIGHTING SYSTEMREPAIR FROM PM - BRAKESAIR HORNDOORHOSES-LINES & FITTINGS

CSHOP-2017-6516 108,35712-7-2017Date Finished: Meter 1 Reading:Date Opened 11-13-2017

TASKS PERFORMED NO PARTS USED

TIRE

Service Requests:

11/10/2017 TIRES / 18: LEAKING / EXCHANGE - NEWBAD TIRES, LARGE BOLT IN THE INNER, PASSENGER SIDE REAR TIRE, TIRE IS FLAT...

Page 111: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2017-6548 108,14211-13-2017Date Finished: Meter 1 Reading:Date Opened 11-13-2017

TASKS PERFORMED NO PARTS USED

TIRE

VENDOR? DAN CALLAGHAN ENTERPRISES

CSHOP-2017-6620 108,50512-18-2017Date Finished: Meter 1 Reading:Date Opened 11-16-2017

TASKS PERFORMED Q PARTS

1 9AP; LIGHT2 9IP; BULB1 5SC; LED PUMP PANEL LIGHT1 LMP; BULB1 2FL; NORM CLSD 2 WIRE PRES SW1 GRO; CONVEX MIRROR

QUALITY CHECK-REPAIRSFOAM SYSTEMRELIEF VALVE FIRE PUMPOIL PAN-GASKETSPOT LIGHTSBRAKESAIR SYSTEMGLASS

Service Requests:

11/15/2017 ENGINE / 18: LEAKING / CORRECTED ON PREVIOUS LINE

11/15/2017 OIL / 20: LUBE/OIL SOAKED / LEAK CAUSED BY CRANK CASE BLOW BYIT IS NOT LOW SORRY ABOUT THE PREVIOUS ENTRY BUT THERE IS A MINOR LEAK FROM THE SEAL TO THE OIL PAN

11/15/2017 SERVICE REQUEST / 18: LEAKING / EXCHANGE - NEWSERVICE REQUEST- AIR LEAK BEHIND THE DASH/ STEERING WHEEL POSSIBLY ASSOCIATED WITH PARKING BRAKE.

WHEN THE BRAKE IS ENGAGED YOU DO NOT HEAR IT AND WHEN YOU DISENGAGE THE BREAK IN ORDER TO DRIVE

YOU CAN HEAR IT. AS IF A BLOW VALVE MAYBE HAVE BEEN ACTIVATED.

11/17/2017 SERVICE REQUEST / 18: LEAKING / COMPLAIN OF AIR LEAK UNABLE TO DUPLICATE COMPLAINMASSIVE AIR LEAK COMING FROM DASH

11/19/2017 SERVICE REQUEST / 49: CAN NOT DUPLICATE CONCERN / OPERATE UNITSERVICE REQUEST- PRESSURE RELIEF IS STICKING AND CAUSING IT TO LEAK. EXERCISED IT SEVERAL TIMES

DURING THE AM CHECKS AND POST FIRE LAST NIGHT

CSHOP-2017-732 105,7672-7-2017Date Finished: Meter 1 Reading:Date Opened 2-3-2017

TASKS PERFORMED Q PARTS

24 9OC; SYN 15W401 9IP; 9IP1 9IP; 9IP1 FIL; NAPAGOLD OIL FILTER1 PLUG; WASHER DRAIN PLUG1 9IP; 9IP

PM SERVICE C

Page 112: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2017-760 105,8172-27-2017Date Finished: Meter 1 Reading:Date Opened 2-6-2017

TASKS PERFORMED Q PARTS

1 STRAINER; STRAINER 2.5 IN1 9IP; BULB1 9IP; 2030-7110-30 CLEAR DOME STEP1 PUMP; TPM/QG HALE REPAIR KIT1 ANODE; 529-0080-10-0 1 1/4 ANODE KIT1 VALVE; VALVE DRAIN CLASS12 WIPER; WIPER BLADES1 9IP; BULB1 BULB; BULB 12 VOLT1 9IP; BULB4 1AD; BATTERY 31 SERIES1 DISPLAY; IGNITION ON DISPLAY1 HORN; ELECTRIC HORN HI1 RELAY; RY48 RELAY24 9OC; BULK TRANS SYN1 2IH; MUFFLER PIPE1 9IP; 29548988 TRANS FILTER ALLISON2 9IP; KIT-AIR HORN-GROVER1 FILTER; 78R5360M 2PK FILTER AIR COND2 9IP; H27W12V BULB

INTAKE VALVEGROUND LIGHT BODYFOAM SYSTEMRELIEF VALVE FIRE PUMPFIRE PUMPEQUIPMENT MOUNTING BRACKETSHOSE BED BODYWIPER BLADESEXHAUST PIPECOOLING SYSTEMINSTRUMENT PANEL LIGHTSDOME LIGHTSLICENSE PLATE LIGHTSTURN SIGNAL LIGHTSBATTERY TRAYBATTERYINDICATOR LIGHTELECTRICALTRANSMISSIONREPAIR FROM PM - BELTSAIR HORNDOOR HINGE-PINS-BUSHINGSFUEL GAUGEA/C FILTER SCREENSQUALITY CHECK-REPAIRS

CSHOP-2018-2280 109,0635-1-2018Date Finished: Meter 1 Reading:Date Opened 4-25-2018

TASKS PERFORMED Q PARTS

2 5TN; TFT ROTATION LOCK INSERT2 1AN; 22`` WIPER BLADE

CONTROL VALVERADIOPANELWIPER BLADESBUMPER FRONTFENDER

Page 113: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2018-3728SPARE ENGINE AT 52Comments:

109,6088-21-2018Date Finished: Meter 1 Reading:Date Opened 7-3-2018

TASKS PERFORMED Q PARTS

3 5AB; 25BALLKITCOMPOSITE2 5TN; TFT ROTATION LOCK INSERT1 5SC; GAUGE1 5TN; GAUGE 356 5TN; GAUGE352 1AN; 22 WIPER BLADE2 2TK; FILTER1 FIL; NAPAGOLD AIR FILTER2 9IP; ALLISON TRANS FLUID GAL-2 9OC; BULK TRANS SYN2 9OC; BULK TRANS SYN1 FIL; NAPA TRANS FILTER1 TWD; AD9KIT MINOR2 2FL; NORMCLSD2WIREPRESSW1 TWD; AD9KIT

FIRE APPARATUSWIPERS-WASHERTRANSFER CASEFILTERREPAIR FROM PM - TRANSMISSIONAIR SYSTEM

Service Requests:

07/01/2018 SERVICE REQUEST / 12: BROKEN / EXCHANGE - NEWDISCHARGE GAUGE #4 ON PUMP PANEL NEEDS REPLACEMENT. GAUGE READS LOWER AND IS OVER 30MMHG

DIFFERENCE FROM MASTER DISCHARGE GAUGE ON THE PUMP PANEL.

CSHOP-2018-3862SPARE ENGINE AT 52Comments:

109,6087-12-2018Date Finished: Meter 1 Reading:Date Opened 7-9-2018

TASKS PERFORMED NO PARTS USED

DIAGNOSE ELECTRICAL

Service Requests:

07/07/2018 SERVICE REQUEST / 18: LEAKING / REPAIRENGINE SHOWS NO INDICATION OF BATTERY CHARGING WHILE PLUGGED IN. ENGINE BATTERY MAY NOT BE

CHARGING WHILE PLUGGED IN.

CSHOP-2018-4429 109,6088-21-2018Date Finished: Meter 1 Reading:Date Opened 8-8-2018

TASKS PERFORMED Q PARTS

1 FIL; FUEL WATER SEPARATOR22 FLUID; SYN OIL BULK QTS1 FIL; NAPAGOLD OIL FILTER1 FIL; NAPAGOLD FUEL FILTER-22 9OC; 15W40 OIL VAL DRUM S SHOP22 9OC; 15W40 OIL VAL DRUM S SHOP

PM SERVICE C

Page 114: Palm Beach County Fire Rescuediscover.pbcgov.org/ofmb/thriftstore/Lists/... · 12/17/2018 Palm Beach County Fire Rescue Fleet Maintenance Asset History 10142417 * FIRE DEPARTMENT

Asset Work Order History 10142417

CSHOP-2018-6182SEE RELATED FILES FOR INSPECTION REPORTComments:

109,82611-5-2018Date Finished: Meter 1 Reading:Date Opened 10-30-2018

TASKS PERFORMED Q PARTS

1 5EF; FOAM TANK LEVEL SENSOR1 5TN; TPMQG HALE REPAIR KIT-1 5TN; SWITCH1 5TN; SWITCH1 9IP; HALE RELIEF VALVE W VULCANIZED SEAT

FOAM SYSTEMRELIEF VALVE FIRE PUMPPRE TRIP INSPECTION

CSHOP-2018-6452 109,82611-14-2018Date Finished: Meter 1 Reading:Date Opened 11-13-2018

TASKS PERFORMED NO PARTS USED

SURPLUS PREP

RADIO-2018-1157 011-2-2018Date Finished: Meter 1 Reading:Date Opened 11-2-2018

TASKS PERFORMED NO PARTS USED

SURPLUS PREP

Service Requests:

11/02/2018 RADIO / / REMOVED RADIO AND EQUIPMENT. TRUCK GOING TO SURPLUS. APX8500 10205859 S/N: 681CTP0432. RADIO NOT IN

ASSET WORKS YET.

RADIO-2018-189REMOVE 10141469 & INSTALL 10205859 INTO SE15 10142417Comments:

03-20-2018Date Finished: Meter 1 Reading:Date Opened 3-20-2018

TASKS PERFORMED NO PARTS USED

MOBILE RELATED

Service Requests:

03/20/2018 RADIO / / REMOVE & INSTALL MOTOROLA MOBILE RADIO INTO SPARE ENGINE 15