Page 1 1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications...

19
page 1 www.photek.co.uk 1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

Transcript of Page 1 1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications...

Page 1: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

page 1www.photek.co.uk1

The TORCH PMT:A close packing, multi-anode, long life MCP-PMT for Cherenkov applications

James Milnes

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

Page 2: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

www.photek.co.uk2

Photek MCP-PMTs

• Photek currently manufacture

the fastest PMTs in the world in

“analogue mode”:

– Whole pulse is captured by an

oscilloscope or digitiser

– Applications often “single-shot,

high intensity”, e.g. Fusion

Research

– We have several detectors on

the diagnostics at the National

Ignition Facility

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

Page 3: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

www.photek.co.uk3

Photek MCP-PMTs

• MCP-PMTs are also the leading detector for

time-resolved photon counting

• Jitter in photon arrival measurements ~ 30

ps FWHM

– Significantly better for multi-photon events

• Excellent fit for Cherenkov-based particle

detection

• Drawbacks:

– Detector Lifetime

– Most models are round, single anode and

not close-packing

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

Page 4: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

www.photek.co.uk4

The TORCH PMT

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

• In November 2012 Photek started the 3-year development of the

TORCH (Timing Of internally Reflected CHerenkov photons) PMT

• A collaboration with CERN and the Universities of Oxford and Bristol

for the LHCb upgrade

– See talk by Maarten Van Dijk, Thursday 14.50

• Technical aims:

– A lifetime of 5 C/cm2 of accumulated anode charge or better

– A multi-anode readout of 8 x 128 pixels

– Close packing on two apposing sides with a fill factor of 88% or better

• 53 mm working width within a 60 mm envelope

Page 5: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

www.photek.co.uk5

The TORCH PMT

• Three main aims:

1. Lifetime

2. High granularity multi-anode

3. Square

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

Page 6: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

www.photek.co.uk6

1. MCP-PMT Lifetime

• Standard MCP detectors suffer from sensitivity loss after prolonged

exposure:

– An MCP has a very large surface area

– Prolonged electron bombardment of this surface releases material that

is ionised

– These ions are drawn back to the photocathode and reduce sensitivity

• Previous solutions have involved barrier films to prevent the ions

reaching the photocathode

– Limited success

– Lowers MCP efficiency and overall sensitivity

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

Page 7: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

www.photek.co.uk7

1. MCP-PMT Lifetime• Recent technology of ALD (Atomic Layer Deposition) coating on MCP has significantly

reduced out-gassing

• Two PMT samples produced in 2011: Double-MCP 10 mm diameter working area

– One with coated MCPs, One control with standard MCPs

• Independently verified by Photek and others: Britting et al (PhotoDet 2012), Conneely et al (VCI 2013)

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

Page 8: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

www.photek.co.uk8

1. MCP-PMT Lifetime

300.0n 400.0n 500.0n 600.0n 700.0n 800.0n 900.0n0.0

10.0m

20.0m

30.0m

40.0m

50.0m

60.0m ALD Coated MCP-PMT Accumulated Anode Charge:

0 C/cm2

0.38 C/cm2

0.71 C/cm2

1.13 C/cm2

1.95 C/cm2

2.49 C/cm2

3.18 C/cm2

3.71 C/cm2

5.11 C/cm2

Pho

tocu

rren

t (A

/W)

Wavelength (m)300.0n 400.0n 500.0n 600.0n 700.0n 800.0n 900.0n

0.0

10.0m

20.0m

30.0m

40.0m

50.0m

60.0m Uncoated MCP-PMT Accumulated Anode Charge:

0 C/cm2

0.13 C/cm2

0.17 C/cm2

0.20 C/cm2

0.25 C/cm2

0.28 C/cm2

0.30 C/cm2

0.32 C/cm2

0.36 C/cm2

Pho

tocu

rren

t (A

/W)

Wavelength (m)

• ALD coating results in no detectable

sensitivity loss after > 5 C/cm2

• Some gain reduction

• 6 test devices produced, 2 successfully

life tested at Photek, 1 currently being

tested at CERN

-0.5 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0

105

106

Gai

n

Integrated Anode Charge (C/cm2)

B5130419Volts per MCP:

600 V 550 V 500 V

G2130614Volts per MCP:

650 V 600 V 550 V

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

Page 9: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

www.photek.co.uk9

1. MCP-PMT Lifetime• 1st year objective: produce 5

long-life MCP-PMTs

– 1st build cycle produced 6

double-MCP devices plus 1

control

– ALD also gives major gain

enhancement

– A 2nd build cycle will

attempt to produce a

photon counting device

with 1 MCP800 1000 1200 1400 1600 1800 2000

102

103

104

105

106

107

Ga

in

Voltage across MCP pair (V)

G1130614 (modified scrub) G2130614 (modified scrub) G1130510 G2130510 B1130419 B4130419 (control) B5130419

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

Page 10: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

www.photek.co.uk10

1. MCP-PMT Lifetime• In other respects, coated MCPs behave

as normal

• Jitter measurement made with 40 ps

laser source

105 106 107 108

Voltages: 200 600 600 1000 200 650 650 1000 200 700 700 1000 200 750 750 1000

PMT225 G1130510PHD

Co

un

ts (

no

rma

lise

d)

Gain

0.0 2.0n 4.0n 6.0n 8.0n 10.0n

-0.7

-0.6

-0.5

-0.4

-0.3

-0.2

-0.1

0.0

PMT225 G1130510200 750 750 1000LPG-1 @ 10 KHz6 dB AttenuatorAveraged 16 times

Vo

ltag

e (

V)

Time (s)

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

Page 11: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

www.photek.co.uk11

1. MCP-PMT Lifetime• At the RICH conference in Japan 2013 Albert Lehmann observed

substantial gain non-uniformity with ALD coated MCPs

• We tried to repeat this observation but could not detect anything

significant

This region is due to an artefact in our scanning software

This region shows the gain suppression after the life test

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

Page 12: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

www.photek.co.uk12

2. High granularity multi-anode• Traditional multi-anode manufacturing uses multiple

pins brazed through a solid ceramic

• Prone to leaking, also unrealistic for a 128 x 8 array!

• Our aim is to use multilayer

ceramic with filled vias

• Much smaller pad size allows

for finer pitch

• The pads on this design are

0.75 mm wide on a 0.88 mm

pitch

Vacuum side Air side

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

Page 13: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

www.photek.co.uk13

2. High granularity multi-anode

• Contact made to anodes by

Anisotropic Conductive Film

(ACF)

– ACF are filled with conductive

particles which provides electrical

interconnection between pads

through the film thickness (z-

direction)

– The conductive particles are

distributed far apart thus not

electrically conductive in the

plane direction (x & y) of the film

– PCB could contain front-end

electronics and/or connectors

Detector

ACF

PCB

x

yz

ACF is insulating in x and y but conducting in z

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

Page 14: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

www.photek.co.uk14

2. High granularity multi-anode - readout• NINO ASIC

• 32 channel differential amplifier

/discriminator developed at CERN

• 10 ps RMS jitter on the leading

edge

• >>10 MHz maximum rate

• The time-over-threshold technique

uses the discriminator output pulse

width to determine the event

charge

• High Performance Time-to-Digital

Convertor (HPTDC)

• A programmable TDC developed for

ALICE time-of-flight RPCs at the LHC

• Two modes of 100 ps LSB resolution

with 32 channels, or 24.4 ps LSB

resolution with 8 channels

• Default maximum rate is 2.5 MHz per

channel, can be increased beyond 10

MHz using higher logic clock

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

Page 15: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

www.photek.co.uk15

2. High granularity multi-anode• Using a method of charge

sharing between pads, we can

reduce the channel count and

the required granularity of the

multi-anode structure

• The plot shows the simulated

position resolution of a parallel

readout, charge sharing

detector (using the NINO and

HPTDC as readout electronics)

in the fine direction of the

required 8 × 64 pad layout but

aiming for 8 × 128 resolution

• The position resolution strongly

depends on the NINO threshold

and detector gain, with this plot

showing a gain of 1 × 106 or

greater being required to

achieve the desired resolution

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

Page 16: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

www.photek.co.uk16

3. Square Tube Development

• Square tube manufacturing is new to Photek

• Currently developing methods of

– Square body brazing

– Square MCP locating

– Square photocathode sealing

– Square anode sealing

• Current status:

– Producing leak-tight square test cells

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

Page 17: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

www.photek.co.uk17

3. Square Tube Development – Anode Seal

• Traditional method of sealing

anode – welding – is unusable

due to close packing

requirements

• We are experimenting with

– Indium seal

– Brazing

– Fritting

2 inch square body with solid ceramic anode indium sealed

Indium seal

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

Page 18: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

www.photek.co.uk18

Summary

• TORCH PMT in development at Photek

• 3 year development aims to finish in November 2015

• 1st year task complete: To produce long-life demonstrators

• 2nd year task on-going: To produce high-granularity multi-anode

demonstrator

• Final year task: Fully functioning detector

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014

Page 19: Page 1  1 The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications James Milnes Workshop on picosecond.

www.photek.co.uk19

Thank you for listening

Workshop on picosecond photon sensors for physics and medical applications, Clermont Ferrand 12th March 2014