Indoor Air Quality CASE Presentation by Traugott Kilgus, June 2012

Indoor Air Quality

byrecordum

MotivationMotivation

To use recordum´s expertise with the (outdoor) airpointer in the field of indoor monitoring

Qualified indoor monitoring needs a number of sensors usually coming from different manufacturers

Measurement data stored in diefferent devices, usually no common data handling and transmission and presentation.

Need of continous unattended many days operation, connected to the internet, remote controlled

To use recordum´s expertise with the (outdoor) airpointer in the field of indoor monitoring

Qualified indoor monitoring needs a number of sensors usually coming from different manufacturers

Measurement data stored in diefferent devices, usually no common data handling and transmission and presentation.

Need of continous unattended many days operation, connected to the internet, remote controlled

Page 3: Page  1 IAQ CASE a concept study, not a design study indoorAir Q logCASE ???

Page 3

IAQ CASEPrototype study

Let´s put all this in a bord CASE

Indoor airpointer CASE Indoor airpointer CASE Indoor airpointer CASE

Page 4: Page  1 IAQ CASE a concept study, not a design study indoorAir Q logCASE ???

Page 4

IAQ CASEThe anytical sensors

Basic sensors

• CO2, Temp, rH• VOC (IAQ)

• airpointer Module for Electrochemical Cells

• PID?

• Thermo pDR-1500 Mass concentration

• altenatively other manufacturers

Page 5: Page  1 IAQ CASE a concept study, not a design study indoorAir Q logCASE ???

Page 5

IAQ CASEThe anytical sensors

Other sensors

• Greywolf IQ 610

VOCs, CO2, CO, %RH, °C, and an extra electro-chemical; O3 or H2S, etc

• GrayWolf's PC-3016six size range particle counters

• What else?

Page 6: Page  1 IAQ CASE a concept study, not a design study indoorAir Q logCASE ???

Page 6

IAQ CASE

In the base part insideIn the base part inside

Power supply. Data logger components from

airQlog Space for cables

Power supply. Data logger components from

airQlog Space for cables

In the top part insideIn the top part inside

PM10 (PM2,5) Monitor pdr1500 Space for other sensor Space for recordum EC Module

PM10 (PM2,5) Monitor pdr1500 Space for other sensor Space for recordum EC Module

YOUR LOGO

In the top part outsideIn the top part outside

rH, Temp., Humidity Sensor rH, Temp., Humidity Sensor

Page 7: Page  1 IAQ CASE a concept study, not a design study indoorAir Q logCASE ???

Page 7

IAQ CASE

in a Hotel near Vienna, Public guest roomsin a Hotel near Vienna, Public guest rooms

A Bar A Coffee A Restaurant This data are gathered with

the kind allowance but also in the interrest of the owner.

We keep the name of the place strictly confidential

A Bar A Coffee A Restaurant This data are gathered with

the kind allowance but also in the interrest of the owner.

We keep the name of the place strictly confidential

Here are the results of the

IAQ monitoring

First test measurements

Page 8: Page  1 IAQ CASE a concept study, not a design study indoorAir Q logCASE ???

Page 8

IAQ CASEin a Bar

The PM10 Monitor kindly cuts the Cigarette smoke peaks at 95 µg/m³

Page 9: Page  1 IAQ CASE a concept study, not a design study indoorAir Q logCASE ???

Page 9

IAQ CASEin a Coffe Room

This 2nd room is next to the Bar, non smoking, but door (sometimes?) open

Page 10: Page  1 IAQ CASE a concept study, not a design study indoorAir Q logCASE ???

Page 10

IAQ CASEin a Restaurant

This 3rd room is next to the coffee room, non smoking, ?……….

Page 11: Page  1 IAQ CASE a concept study, not a design study indoorAir Q logCASE ???

Page 11

in a Hotel near Vienna, Public guest roomsall days

Humidity (blue) good, Temperature (red) o.k., CO2 good, means always good Oxygen Content in the room air, Particulate PM10 concentration depending mainly on Cigarette Smoke ?

Factory calibration, no site calibration, CO2 values ca.100ppm too low ! Needs calibration

RestaurantCoffee RoomBar

Page 12: Page  1 IAQ CASE a concept study, not a design study indoorAir Q logCASE ???

Page 12

Die Messgeräte befinden sich in einem Behältnis aus Karton um über eine Klappe zB Zigarettenrauch einblasen zu können. Eine einigermaßen gleichmäßige Verteilung der Rauches im Karton wird angenommen. Der Karton ist nicht ganz dicht sodass auch Umgebungsluft aufgenommen wird. Beide hier gezeigten Messgeräte haben eine eigene Ansaugpumpe. Der Messaufbau befindet sich unter einem Flugdach welche als Lager genutzt wird. Im Nachbargarten wurde an diesem trüben Tag gegrillt und Feuer gemacht.s

IAQ CASE vs. TEOM

Page 13: Page  1 IAQ CASE a concept study, not a design study indoorAir Q logCASE ???

Page 13

Basic School in Lower Austria

Page 14: Page  1 IAQ CASE a concept study, not a design study indoorAir Q logCASE ???

Page 14

Basic School in Lower Austriaone day !!??

Page 15: Page  1 IAQ CASE a concept study, not a design study indoorAir Q logCASE ???

Page 15

Protestant CHURCH in Lower Austria

Page 16: Page  1 IAQ CASE a concept study, not a design study indoorAir Q logCASE ???

Page 16

See CASE Study ALG Himberg Clinical test animals cages

Page 17: Page  1 IAQ CASE a concept study, not a design study indoorAir Q logCASE ???

Page 17

IAQ CASE

Do you like it?Comments please

Thank you for your attention

Page 18: Page  1 IAQ CASE a concept study, not a design study indoorAir Q logCASE ???

Page 18

IAQ CASE

Another way to present data measured at the same place

Page 19: Page  1 IAQ CASE a concept study, not a design study indoorAir Q logCASE ???

Page 19

IAQ CASE

This is a placeholder textThis is a placeholder text

This is a placeholder text. This text can be replaced with your own

text. All phrases can be replaced with your own text.

This is a placeholder text. This text can be replaced with your own

text. All phrases can be replaced with your own text.

This is a placeholder textThis is a placeholder text

This is a placeholder text. This text can be replaced with

your own text.

This is a placeholder text. This text can be replaced with

your own text.

Placeholderfor text

YOUR LOGO

Placeholder for your own sub headline