Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string...

17
SWELL ASSEMBLY & INSTALLATION INSTRUCTIONS TABLE OF CONTENTS pg. 2-5..........................................SWELL SINGLE pg. 6-9.........................SWELL STRING VERTICAL pg. 10-13................SWELL STRING HORIZONTAL pg. 14-17 ...............................SWELL CHANDELIER

Transcript of Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string...

Page 1: Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string pg. 8 screw cable nut onto socket as shown 2 5 connect lamps and extension cord

SWELLASSEMBLY & INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS

pg. 2-5..........................................SWELL SINGLEpg. 6-9.........................SWELL STRING VERTICALpg. 10-13................SWELL STRING HORIZONTALpg. 14-17...............................SWELL CHANDELIER

Page 2: Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string pg. 8 screw cable nut onto socket as shown 2 5 connect lamps and extension cord

pg. 2

SWELLSINGLE

120V ASSEMBLY & INSTALLATION INSTRUCTIONS

Page 3: Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string pg. 8 screw cable nut onto socket as shown 2 5 connect lamps and extension cord

CEILING MOUNT120V ASSEMBLY INSTRUCTIONS

SWELL SINGLELOOSEN STRAIN RELIEF CAP AND FEED CORD THROUGH ALL COMPONENTS

ATTACH MOUNTING PLATE TO JUNCTION BOX. CONNECT BUILDING WIRING TO FIXTURE WIRING. CONNECT FIXTURE GROUND WIRE AND BUILDING GROUND WIRE TO GREEN GROUND SCREW ON MOUNTING PLATE

IMPORTANT: WE RECOMMEND CEILING MOUNTING BE INSTALLED BY AN ELECTRICIAN

LOCK NUT

STRAIN RELIEF CAP

COVER

1 3

MOUNTING PLATE

TIGHTEN STRAIN RELIEF CAP AT DESIRED HEIGHT

pg. 3pg. 2

AND CUT CORD, LEAVING 6 INCHES FOR WIRING

6” (15.24 CM) RECOMMENDED FOR

CONNECTIONTO BUILDING WIRING

WHITE (N

)

G

REEN

(G)

BLAC

K (L)

Page 4: Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string pg. 8 screw cable nut onto socket as shown 2 5 connect lamps and extension cord

pg. 4

CEILING MOUNT120V ASSEMBLY INSTRUCTIONS

SWELL SINGLE

BULB TYPEPAR30SN-E26-14.5W-3000K-40°

CORD LENGTH10FT (305CM)

ELECTRONICLOW VOLTAGE DIMMERRECOMMENDED

CARE INSTRUCTIONSWIPE CLEAN WITH A SOFTDAMP CLOTH. AVOIDAMMONIA-BASED CLEANERS

SLIDE COVER UP TO CEILING, THEN SECURE COVER TO PLATE WITH THE LOCK NUT4

Page 5: Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string pg. 8 screw cable nut onto socket as shown 2 5 connect lamps and extension cord

pg. 5

[email protected] MARIN STREET

SAN FRANCISCO, CA94124

PABLODESIGNS.COM

SWELLSINGLE

Page 6: Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string pg. 8 screw cable nut onto socket as shown 2 5 connect lamps and extension cord

SWELLSTRING

120V VERTICAL CABLE ASSEMBLY & INSTALLATION INSTRUCTIONS

pg. 6

[email protected] MARIN STREET

SAN FRANCISCO, CA94124

PABLODESIGNS.COM

Page 7: Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string pg. 8 screw cable nut onto socket as shown 2 5 connect lamps and extension cord

SWELL STRING

pg. 7

1LINE GRID CIRCLE CURVE

NOTE: INSTALLATION REQUIRES WIRE CUTTERS AND A STANDARD PHILLIPS HEAD SCREW DRIVER

SUGGESTED HANGING CONFIGURATION

1. DETERMINE APPROPRIATE HEIGHT ABOVE SURFACE FOR LOWEST LAMP 2. SPACE EACH LAMP 22-28 INCHES (56-71CM) FROM THE CENTER OF PREVIOUS LAMP3. AFTER LAYOUT IS DETERMINED, MARK PLACEMENT ON CEILING

NOTE: SPACE FIRST LAMP UP TO 120 INCHES FROM POWER SOURCE UNLESS USING AN ADDITIONAL EXTENSION CORD

COMPONENT LIST

ABCDEFGHIJKLMNO

ANCHORFEMALE CABLE LOCK MOUNTCABLE LOCK SCREWMALE CABLE LOCK MOUNTPOWER FEED CORDCABLEFEMALE CONNECTORMALE CONNECTORCORD NUTCABLE NUTEND CAPSOCKETSHADECHECK RINGBULB

IMPORTANT: WE RECOMMEND FIXTURE BE INSTALLED BY AN ELECTRICIAN.

WARNING: MAXIMUM OF 34 INTERCONNECTED 14.5W LAMPS, DO NOT EXCEED 500 TOTAL WATTS

POTENTIAL HANGING ARRANGEMENTS

CABLE LOCK INSTALLATION

NOTE: TAP UNTHREADED TIP OF THE ANCHOR INTO THE CEILING, THEN USE PHILLIPS SCREW- DRIVER TO COMPLETE INSTALLATION

22-28”

MAX CABLE LENGTH 10 FEET

22-28”

A

CD

F

H

J

KL

B

E

G

I

N

O

M

INSTALL FEMALE CABLE LOCK MOUNT

PLACE CABLE IN SLOT AS SHOWN. THREAD MALE CABLE LOCK MOUNT HALF-WAY INTO FEMALE CABLE LOCK MOUNT.

DEPRESS NIPPLE ON CABLELOCK TO ADJUST CABLE TO DESIRED LENGTH AND SCREW MALE CABLE LOCK COMPLETELY IN TO FINISH INSTALLATION

NOTE: CUT EXCESSCABLE ONCEINSTALLATION ISCOMPLETE

INSTALL ANCHOR B C DA

Page 8: Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string pg. 8 screw cable nut onto socket as shown 2 5 connect lamps and extension cord

SWELL STRING

pg. 8

SCREW CABLE NUT ONTO SOCKETAS SHOWN

2

CONNECT LAMPS AND EXTENSION CORD5

THREAD CHECK RING ONTO SOCKETTO CAPTURE AND SECURE SHADE3 SCREW IN BULB4

NOTE: FOR NARROW SHADE, USE PROVIDED SOCKET EXTENDER TO INSTALL BULB

C INSERT MALE CONNECTORINTO FEMALE CONNECTOR ONPOWER FEED CORD, ENSURE PROPER ALIGNMENT, AND SCREW IN CORD NUT

B INSERT MALE CONNECTORINTO SOCKET, ENSURE PROPER ALIGNMENT, ANDSCREW IN CORD NUT

ENSURE END CAP IS ON THE LAST LAMP

A PINCH SIDES AND PULL TO REMOVE END CAP

Page 9: Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string pg. 8 screw cable nut onto socket as shown 2 5 connect lamps and extension cord

pg. 9

SWELL STRING

ZIP-TIE POWER CORD ON THE FIRSTLAMP TO CABLE AS SHOWN

7

POWER CONNECTION(OPTION ONE)

6

PLUG POWER CORDINTO OUTLET

LOOSEN STRAIN RELIEF CAP AND FEED CORD THROUGH ALL COMPONENTS

LOCK NUT

STRAIN RELIEF CAP

COVER

B

MOUNTING PLATE

CUT OFF OUTLET PLUGA

POWER CONNECTION(OPTION TWO)

6

BULB TYPE PAR30SN-E26-14.5W-3000K-40°

ELECTRONIC LOW VOLTAGE DIMMER RECOMMENDED

CARE INSTRUCTIONS WIPE CLEAN WITH A SOFT DAMP CLOTH. AVOID AMMONIA-BASED CLEANERS

D ATTACH MOUNTING PLATE TO JUNCTION BOX,CONNECT BUILDING WIRING TO FIXTURE WIRING. CONNECT FIXTURE GROUND WIRE TOAND BUILDING GROUND WIRE TO GREEN GROUND SCREW ON MOUNTING PLATE. SLIDECANOPY COVER UP TO CEILING, THEN SECURECOVER TO PLATE WITH THE LOCK NUT

C TIGHTEN STRAIN RELIEF CAP AT DESIRED HEIGHT, ADDING 2-3 INCHES FOR CORD DRAPE. CUT CORD, LEAVING 6 INCHES ABOVE THE RELIEF CAP FOR WIRING

6” (15.24 CM) RECOMMENDED FOR

CONNECTIONTO BUILDING WIRING

WHITE (N

)

G

REEN

(G)

BLAC

K (L)

Page 10: Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string pg. 8 screw cable nut onto socket as shown 2 5 connect lamps and extension cord

SWELLSTRING

120V HORIZONTAL CABLE ASSEMBLY & INSTALLATION INSTRUCTIONS

pg. 10

[email protected] MARIN STREET

SAN FRANCISCO, CA94124

PABLODESIGNS.COM

Page 11: Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string pg. 8 screw cable nut onto socket as shown 2 5 connect lamps and extension cord

SWELL STRING

pg. 11

LINE

GRID

NOTE: INSTALLATION REQUIRES WIRE CUTTERS, ADJUSTABLE WRENCH, DRILL, 1/16” DRILL BIT, AND A STANDARD PHILLIPS HEAD SCREW DRIVER

POWER FEED CORDFEMALE CONNECTORMALE CONNECTORCORD NUTCABLE NUTTURNBUCKLECABLEEND CAPSOCKETSHADECHECK RINGBULB

IMPORTANT: WE RECOMMEND FIXTURE BE INSTALLED BY AN ELECTRICIAN.

WARNING: MAXIMUM OF 34 INTERCONNECTED 14.5W LAMPS, DO NOT EXCEED 500 TOTAL WATTS

WARNING: TURNBUCKLE MUST BE INSTALLED ON A STUD

POTENTIAL HANGING

ARRANGEMENTS

1 TURNBUCKLE INSTALLATION

C

A

E

HI

B

D

K

L

J

F G

SUGGESTED HANGING CONFIGURATION

1. DETERMINE APPROPRIATE HEIGHT ABOVE SURFACE FOR LOWEST LAMP2. SPACE EACH LAMP 22-28 INCHES (56-71CM) FROM THE CENTER OF PREVIOUS LAMP3. SPACE FIRST LAMP UP TO 120 INCHES FROM POWER SOURCE UNLESS USING AN ADDITIONAL EXTENSION CORD

NOTE: WE RECOMMEND INSTALLING ONE VERTICAL CABLE MOUNT FOR EVERY THREE LAMPS HUNGON HORIZONTAL CABLE FOR MINIMAL CABLE SAG. REFERENCE SWELL STRING VERTICAL CABLE ASSEMBLY INSTRUCTIONS FOR INSTALLATION.

NOTE: MAXIMUM OF 12 LAMPS CAN BE HUNG ON 30’ LENGTH OF CABLE

COMPONENT LIST

ABCDEFGHIJKL

MAX CABLE LENGTH 30 FEET

22-28”

FULLY EXTEND TURNBUCKLECOMPONENTS SO THAT 1/4”OF THREADS ARE ENGAGED

NOTE: TOP BARREL IS REVERSETHREADED

A

INSTALL SECOND TURNBUCKLEE

FASTEN TURNBUCKLE TO WALL

NOTE: TURNBUCKLE MUST BEINSTALLED ON A STUD

NOTE: ENSURE TURNBUCKLE IS FULLYEXTENDED TO MAXIMIZE ADJUSTABILITY

B

WHILE HOLDING TOP BARREL,TWIST CENTRAL BARREL BY HANDTO TENSION THE CABLE

F

INSERT CABLE INTO FIRST TURN-BUCKLE THEN FULLY TIGHTEN BOTH SET SCREWS WITH 2MM HEX KEY

C

WHEN CABLE IS FULLYTENSIONED, TIGHTEN NUTS AS SHOWN TOLOCK CENTRAL BARREL IN PLACE

G

MARK PLACEMENT FOR BASEPLATE AND DRILL 1/16” PILOT HOLES

FASTEN TO WALL USING PROVIDED WOOD SCREWS

REPEAT STEPS A AND BWITH SECOND TURNBUCKLE

CUT CABLE TO LENGTH, LEAVINGAPPROX 1” EXTRA FOR ADJUSTMENT

REPEAT STEP C AFTER CABLEIS CUT TO LENGTH

HOLD TOP BARRELWHILE TENSIONING CABLE

Page 12: Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string pg. 8 screw cable nut onto socket as shown 2 5 connect lamps and extension cord

SWELL STRING

pg. 12

SCREW CABLE NUT ONTO SOCKETAS SHOWN

2

CONNECT LAMPS AND EXTENSION CORD5

THREAD CHECK RING ONTO SOCKETTO CAPTURE AND SECURE SHADE3 SCREW IN BULB4

A INSERT MALE CONNECTORINTO FEMALE CONNECTOR ONPOWER FEED CORD, ENSURE PROPER ALIGNMENT, AND SCREW IN CORD NUT

ENSURE END CAP IS ON THE LAST LAMP

B INSERT MALE CONNECTORINTO SOCKET, ENSURE PROPER ALIGNMENT, ANDSCREW IN CORD NUT

A PINCH SIDES AND PULLTO REMOVE END CAP

NOTE: FOR NARROW SHADE, USE PROVIDED SOCKET EXTENDER TO INSTALL BULB

Page 13: Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string pg. 8 screw cable nut onto socket as shown 2 5 connect lamps and extension cord

pg. 13

SWELL STRING

ZIP-TIE POWER CORD ON THE FIRST LAMP TO CABLE AS SHOWN7

POWER CONNECTION(OPTION ONE)

6LOOSEN STRAIN RELIEF CAP AND FEED CORD THROUGH ALL COMPONENTS

LOCK NUT

STRAIN RELIEF CAP

COVER

B

MOUNTING PLATE

CUT OFF OUTLET PLUGA

POWER CONNECTION(OPTION TWO)

6

BULB TYPE

ELECTRONIC LOW VOLTAGE DIMMER RECOMMENDED

CARE INSTRUCTIONS WIPE CLEAN WITH A SOFTDAMP CLOTH. AVOID AMMONIA-BASED CLEANERS

PLUG POWER CORDINTO OUTLET

E SLIDE COVER UP TO CEILING, THEN SECURE COVER TO PLATE WITH THE LOCK NUT

PAR30SN-E26-14.5W-3000K-40°

C TIGHTEN STRAIN RELIEF CAP AT DESIRED HEIGHT, ADDING 2-3 INCHES FOR CORD DRAPE. CUT CORD, LEAVING 6 INCHES ABOVE STRAIN RELIEF CAP FOR WIRING

D ATTACH MOUNTING PLATE TO JUNCTION BOX,CONNECT BUILDING WIRING TO FIXTURE WIRING. CONNECT FIXTURE GROUND WIRE TOAND BUILDING GROUND WIRE TO GREEN GROUND SCREW ON MOUNTING PLATE

6” (15.24 CM) RECOMMENDED FOR

CONNECTIONTO BUILDING WIRING

WHITE (N

)

G

REEN

(G)

BLAC

K (L)

Page 14: Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string pg. 8 screw cable nut onto socket as shown 2 5 connect lamps and extension cord

SWELLCHANDELIER

120V ASSEMBLY & INSTALLATION INSTRUCTIONS

pg. 14

[email protected] MARIN STREET

SAN FRANCISCO, CA94124

PABLODESIGNS.COM

Page 15: Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string pg. 8 screw cable nut onto socket as shown 2 5 connect lamps and extension cord

SWELL CHANDELIER

pg. 15

ANCHOR PLATE INTO CEILING STUDSWITH PROVIDED WOOD SCREWS IF POSSIBLE. IF NOT, USE PROVIDED CEILING ANCHORS AND WOOD SCREWSTO SECURE PLATE TO CEILING

3

ATTACH PLATE TO JUNCTION BOX WITHPROVIDED JUNCTION BOX MACHINESCREWS

2

ROUTE BUILDING WIRINGTHROUGH MOUNTING PLATE1

NOTE: INSTALLATION REQUIRES STANDARD PHILLIPS HEAD SCREW DRIVER AND #2 FLAT HEAD SCREW DRIVER

SUGGESTED HANGING CONFIGURATIONS

1. DETERMINE APPROPRIATE HEIGHT ABOVE SURFACE FOR LOWEST LAMP 2. SPACE EACH LAMP 3.5 INCHES (9CM) ABOVE THE PREVIOUS LAMP3. MOVE UPWARDS IN A SPIRAL PATTERN

10-14 IN(25.4-35.5CM)

120 IN(305CM)

MAX

IMPORTANT: WE RECOMMEND FIXTURE BE INSTALLED BY AN ELECTRICIAN. SWELL CHANDELIER MUST BE SECURELY ANCHORED TO 150LBS RATED JUNCTION BOX OR MOUNTED TO CEILING STUDS.

2

3

SWELL CHANDELIER 3

SWELLCHANDELIER 6

SWELLCHANDELIER 3

SWELLCHANDELIER 6

38 IN(96.5CM)

60-70 IN(152-178CM)

Page 16: Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string pg. 8 screw cable nut onto socket as shown 2 5 connect lamps and extension cord

SWELL CHANDELIER

pg. 16

ALIGN HOLES ON MOUNTING PLATEWITH CORRESPONDING HOLES ON CANOPY COVER

4

ATTACH CABLE HOOKS TO CABLE MOUNTS ON CANOPY COVER TO SUPPORT CANOPY COVER DURING INSTALLATION. CABLE HOOKS MUST REMAIN ATTACHED TO CANOPY COVER TO ENSURE SAFE INSTALLATION

5

PULL PENDANTS TO DESIRED HEIGHT REFERENCINGSUGGESTED HANGING CONFIGURATIONS. USE #2 FLAT HEAD SCREW DRIVER TO SET STRAIN RELIEFS

USING THE SUGGESTED HANGING CONFIGURATION AS A GUIDE, FEED PENDANT CORDS THROUGH ASSIGNED HOLES IN CANOPY COVER AND STRAIN RELIEFS

6

PRESS RUBBER PLUGS INTO UNUSED HOLES FROM INSIDE OF CANOPY COVER8

NOTE: INSTALLATION SHOWN IS FOR SWELL CHANDELIER 3. FOR SWELL CHANDELIER 6, FOLLOW THE SAME WIRING PROCESS USING THE HOLE PLACEMENT OUTLINED IN SUGGESTED HANGING CONFIGURATIONS

7

Page 17: Pablo Assembly Swell all webpablodesigns.com/uploads/pablo_assembly_swell_all_web_r2.pdfswell string pg. 8 screw cable nut onto socket as shown 2 5 connect lamps and extension cord

pg. 17

SWELL CHANDELIER

CONNECT BUILDING WIRING TO LEAD WIREUSING PROVIDED WIRE NUTS10

ENSURE ALL CABLES AND CORDS ARE TUCKED WITHIN CANOPY COVER.LIFT CANOPY COVER UP TO CEILING AND SECURE TO MOUNTING PLATE WITH PROVIDED CANOPY COVER MACHINE SCREWS

11

CUT CORDS TO REACH 12-PORT TERMINALBLOCKS, ALLOWING FOR 3” OF EXTRA CORDPAST TERMINAL BLOCKS. STRIP CORDS SO LEAD WIRES ARE EXPOSED, THEN WIRE CORDS TO TERMINAL BLOCKS AS SHOWN AND SECURE WITH #2 FLAT HEAD SCREW DRIVER

9

9