PA-1000/PA-2000Professional Stereo Power Amplifiers User and Installation Manual
www.factorelectronics.com [email protected]
SAFETY INSTRUCTIONS
RISK OF ELECTRIC SHOCK DO NOT OPEN
IMPORTANT SAFETY INSTRUCTIONS• Read and keep these instructions.• Heed all warnings and follow all instructions contained within this manual.• Do not use this unit near water.• Clean only with dry cloth.• Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.• Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.• Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.• Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.• Only use attachments/accessories specified by the manufacturer.• Unplug this apparatus during lightning storms or when unused for long periods of time.• Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as when the power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.• Operate the product only with the voltage specified on the unit. Fire and/or electric shock may result if a higher voltage is used.• Do not modify, kink, or cut the power cord. Do not place the power cord in close proximity to heaters and do not place heavy objects on the power cord and/or the product itself, doing so may result in fire or electrical shock.• Replace the protective cover over the speaker terminals after installation. Do not touch the speaker terminals as electric shock may result.• Ensure that the safety ground terminal is connected to a proper ground. Never connect the ground to a gas pipe, as a severe explosion and/or fire may result.• Be sure the installation of this product is stable, avoid slanted surfaces as the product may fall and cause injury, property damage, electrocution and/or fire.• Note when the unit is turned off it is not completely disconnected from the wall AC power outlet. Do not open the cover. REFER ALLSERVICE TO A QUALIFIED SERVICE TECHNICIAN
WARNING! TO REDUCE THE RISK OFFIRE OR ELECTRIC SHOCK, DO NOTEXPOSE THIS APPLIANCE TO RAINOR MOISTURE.
CAUTION! TO REDUCE THE RISK OFSHOCK, DO NOT REMOVE THE COVER,NO USER SERVICABLE PARTS INSIDE.REFER SERVICE TO A QUALIFIEDSERVICE TECHNICIAN.
2
2
www.factorelectronics.com [email protected]
PRODUCT OVERVIEW
Thank you for choosing the Factor Electronics PA-1000/2000 Professional Stereo Amplifier. The PA-1000/2000 amplifiers aredesigned to provide ultra high quality amplification for multiple professional applications. The PA-1000/2000 provide state of the art protection circuitry including thermal, short circuit, output DC offset and power ON/OFF muting to eliminate pops and thumps when powering your audio system. A switchable limiter is also provided which protects the amplifier and connected speakers from input overload conditions. The PA-1000/2000 amplifiers provide front panel LED status indicators for signal present, signal clip, protect mode, parallel mode, bridge mode and power ON mode. Please read this entire manual to get the most from your PA-1000/2000 professional power amplifier.
PA-1000/2000 AMPLIFIER FRONT PANEL
The PA-1000/2000 kit includes the following parts:1. 1 x PA-1000/2000 Amplifier2. 1 x Rack mounting ears3. 1 x 14awg 115V power cable and extra AC mains fuse 4. 1 x Installation Guide/Operation Manual
PROT, lights red upon powerON sequence (approx 5 sec)If the PROT lights constantly power the amplifier OFF
Channel 1/2 input level controls
CLIP LED's flash at -3dB before clippingIf the CLIP LED'slight solid reduce thechannel input level
Master power ON/OFF
SIG signal presentLED's light when aninput signal is active
The BRIDGE LED lights when the back panel BRI switch is ONCH-A input will be broadcast. Amps A & B will be combined (see speaker connections on the next page)
3
3
www.factorelectronics.com [email protected]
PA-1000/2000 AMPLIFIER REAR PANEL
AC input socket
Twist lock speaker connectorsChannel A/B. Use the Factor Electronics SPK-4P type connector here
0
Channel A/B speakeroutput terminals acceptdirect wire-in or speakerBanana JacksUse the Factor ElectronicsBanana-R or B connectors
Balanced XLR female line level audio input connectors channels A/BPin 1 – ground/shieldPin 2 - + positivePin 3 - - negative
Balanced/Unbalanced TRS female line level audio input connectors channels A/BTip - + positiveRing – negativeSleeve – ground/shieldNOTE: The TRS input jacks are paralleled to the XLR input jacks. Using the TRS as an input jackallows the XLR jack to be used as an output whichcan be connected to an additional amplifier input
Limiter ON/OFFON limits all inputlevels to max 0dB
MODE SWITCHPARALLEL: Input A will broadcast in outputs A & B STEREO: Input A will broadcast in output A Input B will broadcast in output BBRIDGE: Input A will broadcast in outputs + A & + B
Amplifier chassis ventsDo not block vents
4
4
www.factorelectronics.com [email protected]
PA-1000/2000 INSTALLATION INSTRUCTIONS
IMPORTANT: The PA-1000/2000 should be placed in a well ventilated location or position. Do not block the vents on the front/back of the chassis. Proper ventilation is required for normal operation. Do not expose the unit to excessive dust and do not allow dust to build up on the unit and block the vent holes in the chassis. Do not place the PA-1000/2000 directly above or below heat-generating components such as another audio amplifier. Be sure to leave at least 2 inches of space to the sides of the chassis with open air flow above and below the unit.INSTALLATION: 1. The PA-1000/2000 can be mounted in an equipment rack using the rack kit that is included with the unit.2. Always disconnect the AC power cord before making any connections.3. Use good quality 12-14awg 2 conductor stranded copper speaker wire for all speaker connections.4. Use good quality balanced input cables like the Factor Electronics PRO-XLR cables.
Parallel configuration using four 8ohm speakers. Set the MODE switch to PAR – PARALLEL. Input source A will broadcast to both amplifier outputs. Use this configuration when all speakers must be driven from the same source.
5
5
Mono Out
Stereo configuration using four 8ohm speakers. Set the MODE switch to STEREO. Each channel of the amplifier can broadcast independent sources from input A or B or be used as a high power stereo amplifier.
Stereo Left Right
www.factorelectronics.com [email protected]
PA-1000/2000 INSTALLATION INSTRUCTIONS
BRIDGE MONO operation. Set the MODE switch to BRI – BRIDGE. The two independent internal amplifiers will be combined to create a single high power amplifier. This is useful when powering a professional sub woofer. In bridge mode input channel A is used as the source (channel B controls are disabled). NOTE: Minimum speaker impedance is 4ohms in bridge mode. Speaker wires must be connected to the + CH-A (positive) and + CH-B (negative)
Dual Amplifier BRIDGE MONO operation. Set the MODE switch to BRI – BRIDGE. The two independent internal amplifiers will be combinedto create a single high power amplifier. This is useful when powering a professional sub woofer. In bridge mode input channel A is used as the source (channel B controls are disabled). Connect the TRS input toCH-A on amp 1 and connect an XLR cable to CH-A on amp 2.NOTE: Minimum speaker impedance is 4ohms. Speaker wires mustbe connected to the + CH-A (positive) and + CH-B (negative)
6
6
Mono Output
Bridge Bridge
Bridge
www.factorelectronics.com [email protected]
PA-1000/2000 CONSTANT VOLTAGE SYSTEMS
IMPORTANT: The PA-1000/2000 amplifiers are capable of driving constant voltage high impedance speaker systems in BRIDGE MONOMode (PA-1000) or in STEREO MODE using the PA-2000 where each channel is capable of 1000 watts output per channel. Constant voltage systems are more commonly referred to as 25 volt or 70 volt systems or commercial sound systems. With this type of system all speakers must be connected to a 25 volt or 70 volt transformer which reflects a higher impedance back to the amplifier. This allows multiple speakers to be connected in parallel to the amplifier without exceeding the minimum impedance rating of the amplifier. The PA-1000/2000 amplifiers are capable of driving a minimum of 4 ohm speaker loads in bridge mono mode. Never connect a combination of 8ohm (no transformer) speakers and 25/70 volt speakers to the same amplifier. Never connect the Left & right channels of the amplifier together. Never combine the – negative channels of the amplifier together. Improper speaker installation can damage the amplifiers and void the warranty. If you are unsure how to connect speakers to the PA-1000/2000 always contact a qualified Factor Electronics technician before connecting speakers to the amplifiers. INSTALLATION: Connecting 25/70 volt speakers to the PA-1000/2000 in BRIDGE MONO MODEUse good quality 14-18awg stranded copper speaker wire. Never run speaker wires parallel to AC wires. If you must cross AC wires always cross at a 90 degree angle. Trim approx 1/4” of insulation from the speaker wire and twist the copper ends. We recommend usingthe Factor Electronics SPK-4P twist lock speaker wire connectors to avoid shorts in the speaker wire. 1. Set the MODE switch to BRI (BRIDGE)2. Connect the source to input CH-A.3. Connect the speaker wires to the SPK-4P connector as follows: positive + to 1+/ negative – to 2+. Now insert and twist the connector.4. Use parallel wiring to connect the transformer coupled speakers.5. Each 70 volt speaker reflects an impedance of 5000ohms @ 1 watt, 500ohms @10 watts, 250ohms @ 20 watts & 166ohms @30 watts6. Divide the number of speakers in the system by the impedance to calculate the minimum impedance of the entire load.
70 Volt transformer coupled speakers tapped @ 10 watts / 60 speakers max = 8.33ohms 70 Volt transformer coupled speakers tapped @ 20 watts / 30 speakers max = 8.33ohms
7
7
www.factorelectronics.com [email protected]
PA-1000/2000 SPECIFICATIONS & WARRANTY
In an effort to constantly provide our valued customerswith the latest advancements in technology, Factor Electronics specifications are subject to change from time to time without notice.
Contact Information: Factor Electronics4159 McConnell Drive Burnaby B.C. Canada V5A-3J7PH: 778-800-1918E-Mail: [email protected]: www.factorelectronics.comWarrantyFactor Electronics amplifiers are warranted to be free from defects in workmanship and materials for a period of three (3) years fromthe date of purchase without charge for partsor labour. This warranty applies only to the original owner. The owners responsibilities are to provide proof of purchase from an authorized Factor Electronics dealer/distributor and transportation to the dealer/distributor the unit was purchased from or Factor Electronics. This warranty does not apply to units that have been subject to misuse, abuse, neglect or improper installation, and does not apply to repairs or alterations made by unauthorized Personnel. This warranty specifically excludes responsibility for consequential damage. Retention of your original bill of sale is required to obtain service under the terms of this warranty.
©2016 Factor Electronics. All rights reserved.All trademarks are the property of their respective owners. Specifications are subject to change without notice. Factor Electronics is not responsible for typographical errors or omissions.
PA-1000 PA-2000
8OHMS (continuous) STEREO 350 WATTS RMS 700 WATTS RMS
4OHMS (continuous) STEREO 540 WATTS RMS 1200 WATTS RMS
2OHMS (peak) STEREO 1500 WATTS EIA 2800 WATTS EIA
8OHMS (continuous) BRIDGE 1090 WATTS 2800 WATTS
4OHMS (continuous) BRIDGE 1600 WATTS 5000 WATTS
INPUT SENSITIVITY 0.9-1.1V (+0/-1dBV) 0.9-1.1V (+0/-1dBV)
INPUT IMPEDANCE 20K OHMS BALANCED10K OHMS UNBALANCED
20K OHMS BALANCED10K OHMS UNBALANCED
FREQUENCY RESPONSE 20Hz-20kHz +/- 0.1dB 20Hz-20kHz +/- 1dB
VOLTAGE GAIN 33 +/-0.5dB 37 +/- 0.5dB
THD + N <0.1% <0.1%
S/N RATIO >105dB >105dB
CROSSTALK <0.05% @ rated power <0.05% @ rated power
DAMPING FACTOR >500 >500
AMPLIFIER CURCUIT SMPS CLASS A/B SMPS CLASS 2H
PROTECTION CIRCUITRY SHORT CIRCUIT,OPEN CIRCUIT, THERMAL, ULTRASONIC, CROWBARRF, REACTIVE MISMATCHED LOADSON/OFF MUTING
SHORT CIRCUIT,OPEN CIRCUIT, THERMAL, ULTRASONIC, CROWBARRF, REACTIVE MISMATCHED LOADSON/OFF MUTING
WARRANTY 3 YEARS 3 YEARS
DIMENSIONS W X H X D 19” 438mm 18.1” 460mm 3.49” 88.8mm 19” 438mm 18.1” 460mm 3.49” 88.8mm
RACKING HEIGHT 2U 2U
SHIPPING WEIGHT 38.8LB - 17.6 KG 47.03LBS – 21.33 KG
8
8