P1 vol4 目次 - kaise.com

40
www.kaise.com V o l .4 GE N ER A L C A T A L OG Electrical Measuring Instruments

Transcript of P1 vol4 目次 - kaise.com

www.kaise.com

Vol.4GENERAL CATALOG

Electrical Measuring Instruments

Battery Checkers

Oscilloscope

Handy mΩ Tester

Low Current DC Clamp Meter

AC / DC Digital Clamp Meters

Automotive Digital Multimeters

Digital Multimeters (Probe Tester)

Digital Insulation Tester

Digital Tachometer

O2 Sensor Checker

AC / DC Digital Clamp Meters

AC Digital Clamp Meters

AC Leakage Clamp Meters

Analog Insulation Testers

Digital Insulation Testers

Handy-Type

Probe Tester

Bench-Top DMM

All-in-one DMM

Card-Type DMM

Analog Multitesters

Triaxial ELF Magnetic Field Meter

Digital Sound Level Meter

Digital Light Meter

Other Testers

Accessories

Mark Descriptions

Contents

Digital Multimeters

Analog Multitesters

Clamp Meters

Insulation Testers

Automotive Testers 3

4

5

7

8

9

9

10

11

12

13

13

14

14

15

15

19

19

19

20

20

20

20

21

21

22

22

22

23

23

23

24

24

24

25

25

29

29

30

30

30

31

31

32

32

32

33

33

34

34

34

35

35

36

37

38

SK-8550

SK-8535

SK-2500

SK-3800

SK-7830

SK-7661

SK-7682

SK-7718

SK-7720 / 7722

KT-2021

SK-6166

SK-6597

SK-6592

SK-3502

SK-8401

SK-8402

SK-7660

SK-7661

SK-7682

SK-7718

SK-7719

SK-7720

SK-7722

SK-7708

SK-7601

SK-7602

SK-7603

SK-7615

SK-7625

SK-7820

SK-7825

SK-3002

SK-3003

SK-3005

SK-3500

SK-3502

KU-2600

KU-2602

SK-6161

SK-6163

SK-6150

SK-6597

SK-6592

SK-4033

SK-4035

SK-6555

KU-1199

SK-6500

KF-32

KF-20

SK-8301

KG-70

KG-75

100-41 / 100-62 / 100-63100-57 / 100-72 / 100-74

792 / 793 / 795 / 944 / 948 / 940818-02 / 819 / 817-03 / 817-17817-19 / 817-25 / 660 / 800 / 851

Note the following WARNINGS and CAUTIONS when using Electric / Electronic Measuring Instruments.

Caution Symbol on the instrument indicates that the user should

read carefully the operating instructions in the manual.

High Voltage Warning Symbol on the instrument indicates that

a potential of 1000V or more high voltage may be present on the

Terminals. The user should use extreme care about safety practices.

Maximum Allowable Ground Voltage Symbol on the instrument

indicates that the maximum voltage between INPUT Terminals

and Earth Ground is 500V in this case. The user must not apply any

voltage that will exceed the maximum voltage.

Safety Symbols1

The ordinary multimeters, analog or digital, are provided with maximum range of

500V to 1000V AC and DC. But, most of them are designed to measure Low Power

Circuits such as TVs, Radios and home electrical apparatus.

Therefore, to measure High Power Circuits or High Power Line more than 220V, such

as Power Supplies for Factory Equipments and Facilities, etc., do NOT use any

ordinary multimeters. Use the instruments especially designed for High Power Line.

High Power Line sometimes includes Surge Voltage more than 10 times of the rated

voltage. So, the Surge Voltage will cause electric shock accidents when measuring

with the ordinary multimeters. Even if the circuit to be measured is of Low Power, if

the voltage is greater than 220V, use the instruments with great care observing

warnings and cautions written in the instruction manuals concerned.

Warnings for High Power Line andHigh Voltage Measurements

2

Traceability ChartTraceability to prove the compliance with national and international standards is an essential factor for measuring instruments used as test instruments associated with quality

assurance. Products of Kaise are calibrated by reference samples which is periodically checked for its compliance with national standards. A calibration certificate and test data

report are available on your request.

Comparative Standards

AC/DC Voltage Resistance Frequency Capacitance Temperature Humidity AC/DC Current

LCR Meter Digital thermohygrometer Current Shunt

National Standards

Calibration Standards

Applied Standards

Calibrated Parameters

National Institute of AdvancedIndustrial Science and Technology

AISTNational Institute of Informationand Communications Technology

NICTNational Institute of Standardsand Technology

NISTJapan Electric Meters InspectionCorporation

JEMIC

High-Accuracy Digital Multimeter

CE Mark

CE marking is a safety mark which can be attached only on a product meeting the safety requirements of the Directive of Council of the European Union (EC

Directive).

A product attached with the CE mark is designed so as to meet the requirements of the "Low Voltage Directive" and "EMC Directive" of the EC Directive. Low

Voltage Directive: This Directive covers products of power supply voltage of 50V-1000V(AC) and 75V-1500V(DC), and it defines electric safety requirements

against shocks, burns, etc. The applicable standard is EN61010 corresponding to IEC1010 give on the left. EMC Directive: This Directive stipulates conditions

so as not to give out strong electromagnetic waves from equipment to the outer environment and to protect equipment from the effect of electromagnetic waves

from the outside.

Higher-numbered categories correspond to electrical environments with greater momentary energy, so a measurement product designed for CAT Ⅲ environments can endure

greater momentary energy than one designed for CATⅡ. Using a measurement product in an environment designated with a higher-numbered category than that for which the

product is rated rated could result in a severe accident, and must be carefully avoided.

Never use a CATⅡmeasuring product in CATⅢ, or Ⅳ environments.

The measurement categories comply with the Overvoltage Categories of the IEC 60664 Standards.

For Safety

The International Safety Standard IEC61010To ensure safe operation of measurement products, IEC 61010 establishes safety

standards for various electrical environments, categorized as CATⅡto CAT Ⅳ, and

called measurement categories. These are defined as follows.

CAT.ⅡPrimary electrical circuits in equipment connected to an AC electrical outlet

by a power cord (portable tools, household appliances, etc)

CAT.ⅢPrimary electrical circuits of heavy equipment (fixed installations) connected directly

to the distribution panel, and feeders from the distribution panel to outlets.

CAT.ⅣThe circuit from the service drop to the service entrance, and to the power

meter and primary over current protection device (distribution panel).

Distribution board

CAT.Ⅳ

CAT.Ⅲ

CAT.Ⅱ

Indoor wiring

Power receptaclePower receptacle

Service entrance

Watthour meter

Service wire

Kaise conforms to IEC 61010-031 (safety standard for hand-held probes) by using test lead caps.Required standards : Exposed metal part must be 4mm or shorter for

CAT IV and III environments to prevent short-circuits from occurring.

Insulation Capfor Test Lead

Cap attachedNo Cap attached

For CAT Ⅱenvironment For CAT Ⅲ and Ⅳ environments

Measuring Instruments in R&D, Production, Inspection and Service Department

Cla

mp

Met

ers

Insu

latio

n Te

ster

s / E

arth

Test

erD

igit

al M

ult

imet

ers

An

alo

g M

ult

ites

ters

Au

tom

oti

ve T

este

rsO

ther

Tes

ters

Acc

esso

ries

Battery Checkers

FEATURES●Can record frequently tested batteries as favorites list.●Can count and record the number of testing.●One-touch printing by Dierct-Print Key available on the instrument.●Detachable battery cable for easy replacement.● Editable header / footer function that can print favorite names or pictures (shop name, etc.) on the printer paper.

SPECIFICATIONSDisplayLanguage (display & print)

PrinterPower SupplyTestable Battery

Battery Standard

Measurement RangeCE MarkDimensions WeightAccessories

LCD (dot matrix display :128×64 dots) Japanese, English (Default setting : English)Bult-in Printerfrom Test Battery or USB connection12V Battery※24V battery : engine startability test and charging system test are available. JIS, EN / DIN, SAE / BCI※CCA input or Industrial battery selectable100 to 1400CCA, Industrial :1.0mΩ to 50.0mΩEN61326-1248(H) x 96(W) x 55(D) mm Approx. 670g800 Battery cable (attached), 934 USB Cable, Printer Paper (x 2, for testing sample, 1 roll is attached in the unit), 1032 Carrying Case

:::::

:

:::::

12VBattery Test

OPTIONAL ACCESSORIES851 Printer Paper800 Battery cable

12V & 24V Start Performance, Charging System Test

How to Test①Connect battery clips to +/- terminals.②Set the testing condition in SK-8550.③Start a Battery Test.④Start a Battery System Test.

Advantages of SK-8550

Header / Footer FunctionCan edit and print the favorite names or pictures (shop

name, etc.) on printer paper as header and footer, by

downloading the user application from Kaise website.

Favorite FunctionCan record up to 50 frequently tested battery codes as

favorite list. You can find the battery to be tested easily

by pressing “FAVORITES” Key. Record name is editable.

You can print out the testing result easi ly by just

pressing direct-print key available on the instrument.

Direct-Print Key

Battery cable tends to be damaged by everyday battery

testing.

For SK-8550, you can replace the battery cable by only

one screwdriver.

Detachable Battery Cable★FAVORITES   ▲▼01/20-72(AC Delco)02/SL-6C(BOSCH)03/572-20(ATLAS)04/1050S(OPTIMA)

Can Record “CCA /mΩ” in Favorite listYou can record “CCA / mΩ” values in favorite list. This

can help easy testing without inputting these values for

every test.

(CCA values are edited into battery codes in the following

example.)

Number of Testing CounterCan count and record the number of testing. This

function helps to check your maintenance record.

View Test Count

Battery Test   52System Test    37  Press Hold : Reset

800 Battery Cable (for replacement)

New and Improved Battery Checker with Advanced Functions

SK-8550

Test Result : Good

Date and Time 2017/03/15 15:00(Aging Test Mode)

Battery Test Report

ABC MechanicalTel XXX-XXX-XXXFax XXX-XXX-XXXE-Mail [email protected]

Periodical test isrecommended.

SOC (State of Charge) : 100%

SOH (State of Health) : 100%

Battery TypeModel No.Measured CCABattery VoltageTemperatureTesting Mode

JISQ-85

615CCA12.780V

24℃

Charge controller / Idle Reduction

Header

Terminal

TerminalBATTERY

CHECKER

MAX 32V

PRINT

FAVORITES

SK-8550

Clam

p Meters

Insulation Testers / Earth TesterD

igital M

ultim

etersA

nalo

g Mu

ltitestersA

uto

mo

tive Testers

Oth

er Testers

Accesso

ries

Battery Checkers

FEATURES● For the automotive batteries with EN/DIN, SAE/BCI, and JIS standards.●Applicable to the vehicles with Charge Controller or Idle Reduction systems.●Auxiliary battery test for TOYOTA-Hybrids.●Attention (Caution) result added.●Double Dierential Pulse Test Method for more accurate testing.●Unused Battery Test Mode.●Carrying Case for Protection.●On-Site Printing with Built-in Printer.●Easy Database Upgrade through KAISE Website.

Advantages of SK-8535

Double Differential Pulse Test Method formore accurate testing

For the automotive batteries withEN/DIN SAE/BCI, and JIS standardsWhat tests available?①Battery Test・Battery Charging Level (SOC) ※SOC:State of Charge・Battery Condition (SOH) ※SOH:State of Health②Battery System Test・Engine Start Performance (Starting ability of the battery)・Charging System (Generating condition of alternator)

5-grade JudgementLED shows the test result by following 5-grade.“Attention” is useful to let the customer know thenecessity of battery replacement to prevent theunexpected battery-down.

SPECIFICATIONSDisplayLanguage (display & print)

PrinterPower SupplyTestable Battery

Battery Standard

Measurement RangeCE MarkDimensions WeightAccessories

LCD (dot matrix display :128×64 dots) Japanese, English, Chinese (Default setting : Japanese)Bult-in Printerfrom Test Battery or USB connection12V Battery※24V battery : engine startability test and charging system test are available. JIS, EN / DIN, SAE / BCI※CCA input or Industrial battery selectable100 to 1400CCA, Industrial :1.0mΩ to 50.0mΩEN61326-1248(H) x 96(W) x 50(D) mm Approx. 550g934 USB Cable, Printer Paper (x 2, for testing sample, 1 roll is attached in the unit), 1035 Carrying Case

:::::

:

:::::

Quick and Accurate Car Battery & System Test with Single Hand-Held Equipment

SK-853512VBattery Test

OPTIONAL ACCESSORIES851 Printer Paper

12V & 24V Start Performance, Charging System Test

Battery Test

System Test

Model No.WidthLength

: 851: Approx. 57mm: Approx. 5.8m

Please Purchase this printer paper for replacement.

Printer Paper ※Option (10 rolls per set)

Built-in PrinterQuick-and-easy printing of the test results from built-in printe.

Applicable to the vehicles with ChargeController or Idle Reduction systemsAccurate testing with the specific test program and standard numbers which are designed for their testing purpose.

Unused Battery Test ModeSpecial mode for testing unused (new) batteries which are stocked in car dealers or garages. This is effective to keep them in good condition preventing unexpected battery aging during storage.

Test Result Saving & PC ConnectionUp to 99 data can be saved to the internal memory.Onforwarding to PC in text data is possible.

Auxiliary battery test for TOYOTA-HybridsApplicable to auxiliary batteries models S34B20 / S46B24 S55D23 / S65D26 which are used for TOYOTA-Hybrid vehicles such as Prius, or Prius C.

Industrial Battery Testing

Carrying Case for ProtectionEnhanced portabi l i ty and dust protection for the instrument.

High-Intensity Polycarbonate Body

Easy Database Upgrade throughKAISE Website※PC and internet connection are required.

Display & Print Language SelectableEnglish / Chinese / Japanese are available.

Built-in PrinterCan print the test results easily and quickly. Language selectable from English / Chinese / Japanese.

Test Result : Good

Date and Time 2016/03/15 15:00(Aging Test Mode)

Battery Test Report

Periodical test isrecommended.

SOC (State of Charge) : 100%

SOH (State of Health) : 100%

Battery TypeModel No.Measured CCABattery VoltageTemperatureTesting Mode

JISQ-85

615CCA12.780V

24℃

Charge controller / Idle Reduction

Battery test result

Testing date and time

Battery charging level (SOC)

Battery aging level(SOH)

Comment fortest result

Battery test mode

Condition oftested battery

System Test ReportDate and Time 2016/03/15 15:00(12V System)

Test Result : Good

Test Result : Good

Periodical test isrecommended.

START PERFORMANCE TEST

CHARGING SYSTEM TEST

CrankingStart Performance

8.619V100%

Charging VoltageRipple Voltage

14.523V0.110V

Testing date and time

Engine start performancetest result

Charging system test result

12V / 24V System

Comment for test result

Battery conditions atengine starting

Battery conditions

CHARGE BADGOOD

Good

Good/Charge

Attention

Charge/Retest

Replace

light

lightlight

flash

light

light

LED lights up or flashby test results

Cla

mp

Met

ers

Insu

latio

n Te

ster

s / E

arth

Test

erD

igit

al M

ult

imet

ers

An

alo

g M

ult

ites

ters

Au

tom

oti

ve T

este

rsO

ther

Tes

ters

Acc

esso

ries

Oscilloscope

SPECIFICATIONSDisplayFrequency bandwidthMax. Sampling RateNumber of ChannelsAcquisition MemoryOscilloscope FunctionInternal Power Supply

External Power SupplyCE MarkDimensions WeightAccessories

Dot matrix LCD (240×128 dots), Display Size : 53mm(H)× 92mm(W)DC to 200kHz2MS / sec. 2 channels4096 pointsGraphic waveform display for voltage measurement1.5V LR6 or R6P batteries 4 pcs.(NiMH rechargeable battery usable)USB mini-B connector (DC5V)EN61010-1 CAT II 300V class 2, EN61326-1162mm(H)×167mm(W)×35mm(D)570g (excluding batteries)Holster (attached to the main unit), 100-57 Test Leads,903 AC/DC Adapter (USB 5V output), 934 USB cable, 1035 Carrying Case, 1.5V R6P Batteries 4 pcs

:::::::

:::::

2ch Hand-held Oscilloscope Especially for Car Mechanics

SK-2500

Advantages of SK-2500

Car Maintenance List - The Auto SetFunction for Car Sensors and SignalsThe most complicated thing to get the observable waveform with oscilloscope is the settings of voltage axis, time axis, and trigger.SK-2500 makes it easier by providing “Car Maintenance List”. Just choosing the sensor or signal to be measured, the instrument automatically adjusts the waveform and shows it on the screen.

Auto Axes AdjustmentAuto Adjustment for voltage and time axes.

Backlight LCDEasy reading even in dark environment.

Data Logger Function andData Processing on PCYou can record the measuring data with Data Logger function and can send it to PC for using in spreadsheet software like making graphs. SK-2500 can store up to 99 CSV and PNG data.

Screen Capturing Saved as Image DataScreen capturing saved as PNG format is available just pressing CAPTURE Key. Captured data can be recalled from the menu list to view on the screen or to move to the PC.You can see the colored image data on PC screen.

AC/DC Adapter PoweringUSB 5V output AC/DC adapter for cont inuous measurement. ※standard accessory

2ch Waveform DisplayTemperature Measurement(with optional temperature probe)

Digital Multimeter Functionin DMM ModeAC/DC Voltages, Resistance, Continuity, Frequency, Pulse Width, Duty Cycle, and Temperature measurements.

Help Function to SupportYour MeasurementPress HELP Key when you have questions in the operation. Help lists with useful hints or tips are displayed on the screen.

Rubber Holster for Shock Protectionand Improved RuggednessStandard oscilloscopes tend to be slippery due to its plastic chassis, and careful handling is required.SK-2500 added rugged so lut ion for hand-he ld oscilloscope with slip-proof rubber holster. This also offers stable placing even in the engine compartment.

Easy-to-Use Hand-Held OscilloscopeWithout Special AccessoriesSK-2500 can use as your daily tool, with oscilloscope, digital multimeter, and data logger in one single hand-held unit. Test probes and accessories are common with our other test & measurement products for enhanced usability.Usable : 100-41 Test Lead Kit, 100-62 Test Lead Set

Large-Sized Luminous Key Switches with Simple OperationFeeling difficulties in complicated key operation for using oscilloscope? Key switches of SK-2500 offers intuitive operation with illumination function, pictorial indications, and guide icons on the screen.

V

DISPHOLD

DUTY

%HzΩ

Graph mode

DMM modeAC/DC

V APOPULSEWIDTH

DATAMEMO

OPTIONAL ACCESSORIES660 AC/DC Clamp Adapter100-57R Red Test Lead100-72 Oscilloscope Test Lead Set100-74 Ripple Voltage Test Lead100-41 Test Lead Kit100-62 Test Lead Set653 RPM Sensor (for Direct Ignition)

650 RPM Sensor (for High Tension Cord)940 Alligator Clips793 Coil-Type Contact Pin944 Test Pin946 Battery Clip818-02 Temperature Probe819 Temperature Probe Other

Resistance

Voltage

DC Voltage Range200.0mV2.000V20.00V200.0V1000V

Resolution100μV

1mV10mV

100mV1V

Max. Input

1000V DC

Accuracy

±1.0%rdg±8dgt

±1.0%rdg±5dgt

V / Div200mV / 2V / 20V

500mV / 5V / 50V / 200V1V / 10V / 100V / 500V

Max. Input

1000Vp-p

Accuracy±4dot±2dot±1dot

DMM mode

Graph mode

Range2.000kΩ20.00kΩ

Resolution1Ω10Ω

Open Circuit Voltage

≦3.3V

Accuracy

±1.0%rdg±8dgt

Continuity Test, Frequency, Pulse Width, Temperature

Range

2.000V

20.00V

200.0V

600V

Accuracy±2.0%rdg±8dgt(45Hz~1kHz)±2.5%rdg±8dgt(1kHz~10kHz)±4.0%rdg±8dgt(10kHz~20kHz)±6.0%rdg±8dgt(20kHz~30kHz)±2.0%rdg±8dgt(45Hz~1kHz)±2.5%rdg±8dgt(1kHz~10kHz)±4.0%rdg±8dgt(10kHz~20kHz)±2.0%rdg±5dgt(45Hz~1kHz)±2.5%rdg±5dgt(1kHz~10kHz)

Max. Input

600V AC(rms)

Resolution

1mV

10mV

100mV

1V

AC Voltage(AC V rms)

※Crest factor 1.5 or less

Clam

p Meters

Insulation Testers / Earth TesterD

igital M

ultim

etersA

nalo

g Mu

ltitestersA

uto

mo

tive Testers

Oth

er Testers

Accesso

ries

Oscilloscope

※See maintenance manual when making the measurement.

Waveform observation of cam and crank sensors in graph mode

Graph mode

DMM mode

Measurement Example

①Insert the Input Plugs of Test Lead to Input Terminals. Turn on the instrument.②Contact the Test Pins to the terminal to be

measured. The below picture is getting the signal input from wire harness connector using 100-41 Test Lead Kit.

Optional Accessories

※Optional 660 AC/DC Clamp Adapter is required.

2ch test for battery voltage and alternator current

①Insert test lead plug to CH1 input terminal, and insert clamp adaptor plug to CH2 input terminal.②Turn on the instrument (SK-2500).※F o r D M M m o d e , e n t e r D C v o l t a g e

measurement mode by pressing Test Mode key.③Contact test pins to the battery terminals.

Red to plus, black to minus.※940 alligator clip is used in the picture below.

④Select 40A range with the clamp adapter.⑤Clamp-on the B-terminal of the alternator.

⑥For graph mode, adjust voltage / time axes. Set trigger hold at 10V to stop the waveform as voltage drop at engine cranking. (set trigger slope as falling edge trigger.)⑦Start the engine.⑧Move and adjust the waveform to be more

visible.⑨Check the result on the LCD.

③Choose the item from Car Maintenance List. Auto set works for voltage / time axes, trigger, and waveform position to display camshaft position sensor waveform in CH1.

④Adjust voltage axis and waveform position to make space for CH2 waveform.⑤Press CH2 Key. Crankshaft position sensor

waveform is displayed on the screen. Adjust the voltage axis to be the same as CH1 and adjust the waveform position.

Battery voltage measurement in DMM mode

①Insert the Input Plugs of Test Lead to Input Terminals. Turn on the instrument.②Press TEST MODE Key to go to DC Voltage

measurement in DMM mode.③Contact the test pins to battery terminals (red

pin to plus terminal, and black pin to minus terminal).

④Read the measurement result on the screen.⑤Start the engine to let the alternator power

generated. Check the measurement value on the LCD that should be increasing. Measuring this voltage is effective to check the generating condition of the alternator.※For charge control vehicles, alternator might

not generate the power.

100-72Oscilloscope Test Lead SetNarrow test pins that can insert wire harness.Included 2 sets of red test leads / test pins allows 2-channels measurement. Use black alligator clip for grounding.

100-74Ripple Voltage Test LeadCan view the Ripple Voltage waveform of the alternator by removing DC elements from the measuring voltage.

Cla

mp

Met

ers

Insu

latio

n Te

ster

s / E

arth

Test

erD

igit

al M

ult

imet

ers

An

alo

g M

ult

ites

ters

Au

tom

oti

ve T

este

rsO

ther

Tes

ters

Acc

esso

ries

Handy mΩ Tester

Low resistance measurement for the motors. Ideal for the maintenance of Hybrid and Electric vehicles.

SK-3800

DISPHOLDCOMP

ΩLOW

SimpleDust Proof

SimpleWater Resistant

FEATURES●Autonotive mΩ Tester focusing on the testing of Hybrid and Electric vehicles.●Easy-to -use handheld unit useful for automotive mechanics.● 4-terminal method for accurate measurement

SPECIFICATIONSDisplaySampling RatePower SupplyFuseCE MarkDimensionsWeightAccessories

::::::::

4199 count LCD, Maximum reading 41992 times / sec 1.5V R6P or AA Batteries (x 8)F22 (0.5A / 600V) x 1EN61326-1140(H) x 130(W) x 70(D) mm600gHolster, 100-71 Test Leads (x 1 set),1035 Carrying Case, 1.5V R6P Batteries (x 8)

Car Measurement with SK-3800

Low resistance measurement ofthe hybrid vehicle motor

①Turn the power switch of the vehicle OFF. Remove the service plug grip.

④Set the measurement range of the SK-3800.

②Remove the inverter cover.

③ D i s c o n n e c t t h e three-phase alternating cu r ren t cab le o f t he hybrid vehicle motor from the inverter.

⑤Make the zero-adjustment for SK-3800.(Press “MEASURE” key with the test lead tips short-circuit. Then, press “0Ω ADJ ” key.)

Measurement Example (with TOYOTA Prius)※Observe the procedures in maintenance manual.

⑥Connect the test leads to the three-phase alternating current cable terminals of the hybrid vehicle motor.

⑦Read the resistance on LCD.

Advantages of SK-3800

Accurate testing with4-terminal measurementEffective for eliminating the impedance contribution of the wiring and contact resistances to ensure the accurate measurement.

Clip-on test lead tips

Large backlit LCD

Hands-free measurement without holding the test leads.

Covered with rubber holster for slip-proof and to prevent scratching on the vehicle body.

Rubber holster for shock protection

Color-coded input terminals and test plugsEasy plug-in to the input terminals by colors. Also helpful in preventing the wrong insertion.

Comparator FunctionHigh/Low judgement by LCD display and buzzer comparing with the preset reference value.

Ω

Range

40mΩ400mΩ4Ω40Ω400Ω4kΩ40kΩ

Accuracy

±0.3%rdg±3dgt

±0.3%rdg±2dgt

Resolution

10μΩ100μΩ1mΩ10mΩ100mΩ1Ω10Ω

Test Current

200mA

2mA

1mA20μA10μA

MaximumApplied Power1.7mW17mW17μW170μW420μW1.7μW4.2μW

Open CircuitVoltage

<5VLOW Ω / Ω

Low resistance measurement is required for hybrid vehicle motor and generator if the DTC code “P0A78 (Drive Motor "A" Inverter Performance) is detected.

In this testing, the resistance to be measured is very low around 100mΩ.

2-terminal measurement like normal Digital Multimeters is not suitable for this level of resistance due to the errors of impedance contribution of the wiring and contact resistances.

SK-3800 can eliminate such errors by 4-terminal measurement which assures the accurate testing.

Clam

p Meters

Insulation Testers / Earth TesterD

igital M

ultim

etersA

nalo

g Mu

ltitestersA

uto

mo

tive Testers

Oth

er Testers

Accesso

ries

φ20mm

ConductorDiameter

Low Current DC Clamp Meter

Quick and Easy Dark Current Measurement Just Clamping-On

FEATURES●Automatic Zero-Adjustment function to adjust LCD

indications into 0±1 digit when powered on.●Stable LCD reading even in low current.●Shielded clamp core prevents external noise or effect

of external magnetic field.

SK-7830

DC

4000mADC

40A/200A DIFF AUTOZERO APODISP

HOLD

DCCurrent

Functions

Accuracyfrom 5mA0A to 100A101A to 200A

±1.5%rdg±5dgt

±3.0%rdg±5dgt

Range4000mA40A200ADifference, Power-on Initialize, Display Hold, Auto Power OFF

SPECIFICATIONSDisplaySampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories

:::::::::

4000 count LCD, Maximum reading 405064 times / sec (Display : 1 time / sec) Manual (4000mA), Auto (40A / 200A)φ20mm Max. 1.5V R6P or AA Batteries (x 2) CATⅢ300V and EMC203(H) x 61(W) x 30(D) mm230g 1011 Carrying Case (x 1)1.5V R6P Batteries (x 2)

Dark Current Measurement

Car Measurement with SK-7830

Dark Current : mA-level low current that is used after turning off the engine by such as car security system or audio settings back-up. Too much dark current causes battery runs out, but its measurement was difficult. SK-7830 solved this problem and make it quick and easy.

③Clamp-on a minus cable of car battery.

④Read the measurement value. If it is higher than the specified value, check ① once again.

Trigger

4000mA Range

Car Alternator's Charging Current Measurement

Car Alternator : Engine generator that outputs DC electricity. Measuring its charging current is effective to find the trouble that might cause battery runs out or battery damages.

①Set the switch to 40A/200A range without touching the trigger lever, not to open the clamp jaws.

②Clamp B-terminal cable from car alternator.③Start the engine.④Read the measurement value on LCD.※Alternator is judged normal if LCD shows 20A

to 40A after the engine started, then slowly turn down.If the current remain unchanged or high current remain displayed, the alternator might be damaged.

Trigger

40A/200A Range

①Leave the engine turned off for about 15 minutes. All electric components (headlights or lamps) must be turned off.②Set the switch to 4000mA range without

touching the trigger lever, not to open the clamp jaws.

Advantages of SK-7830

For Car Maintenance Wide range of DC current measurement is possible from 4000mA to 200A range.

Stable ReadingEven in low current measurement, SK-7830's LCD reading is always stable.Generally, low current measurement value is hard to read due to its instability. SK-7830 solved this problem by its own internal processing system to minimize reading-instability.

Small-Sized Clamp Head SK-7830's small clamp head assures easy clamping even for narrow conductors such as the cables around car engine.

Power-On InitializeAutomatic Zero-Adjustment function to adjust LCD indications into 0±1 digit when powered on.

Newly-Developed External-Noise-PreventableCore MechanismShielded clamp core prevents external noise or effect of external magnetic field.

DC4000mA

DC40A/200A

φ20mm Max

Cla

mp

Met

ers

Insu

latio

n Te

ster

s / E

arth

Test

erD

igit

al M

ult

imet

ers

An

alo

g M

ult

ites

ters

Au

tom

oti

ve T

este

rsO

ther

Tes

ters

Acc

esso

ries

AC / DC Digital Clamp Meters

Car Measurement with SK-7661

Alternatorcharging currentClamp-on the B-terminal of the alternator.

MAXM I N

Handy-size Clamps with Efficient Functions

AC/DC

VAC/DC

400A DIFFDUTY

%HzΩfor DC Currentmeasurement

AUTOZERO APODISP

HOLD

φ27mm

ConductorDiameter

SPECIFICATIONSDisplay

Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories

:

::::::::

4000 count LCD, Maximum reading 40503 times / secAuto Rangingφ27mm Max. 1.5V R03 or AAA Batteries (x 2)CATⅢ 300V, CATⅡ 600V and EMC 170(H) x 58(W) x 27(D)mm 160g100-63 Test Leads (x 1 set)1015 Carrying Case (x 1)1.5V R03 Batteries (x 2)

Accuracy±1.5%rdg±3dgt40 to 200A201 to 300A301 to 400A±1.5%rdg±5dgt (50/60Hz)40 to 200A201 to 300A301 to 400A±0.2%rdg±2dgt±1.0%rdg±3dgt

±1.0%rdg±2dgt

±1.5%rdg±5dgt (40 to 400Hz)

±0.2%rdg±2dgt

±1.0%rdg±3dgt±1.5%rdg±5dgt±0.7%rdg±3dgt±1.2%rdg±5dgt±3.0%rdg±5dgt±1.5%rdg±5dgt±5.0%rdg±5dgt±1.5%rdg±5dgt

±5.0%rdg±5dgt

±1.5%rdg±5dgt±3.0%rdg±3dgt±4.0%rdg±3dgt

±2.0%rdg±3dgt (50/60Hz)±4.0%rdg±5dgt (50/60Hz)±5.0%rdg±5dgt (50/60Hz)

*Frequency Characteristic (40 to 400Hz) : 40A Range (0.5 to 9A) add 1.5% (10 to 40A) add 0.5% 400A Range add 1.0%

A / A Hz

V / VHz / %

Range40A

400A

40A

400A

5Hz to 1kHz400mV4V40V400V600V4V40V400V600V5Hz to 49.99kHz5% to 95%400Ω4kΩ40kΩ400kΩ4MΩ40MΩ400ΩBuzzer Sound : Approx. 50Ω or less0 to 1.5VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF(±5.0%rdg±10dgt)MAX / MIN Difference, Power-on Initialize (for DC Current measurement),Display Hold, Auto Power OFF

DCVoltage

ACVoltage

DCCurrent

ACCurrent*

Frequency

Frequency

Duty Cycle

Resistance

Continuity Test

Functions

Diode Test

Capacitance

Battery voltageContact test lead pins to the battery. Black to minus, red to plus.

OPTIONAL ACCESSORIES940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin

944 Test Pin946 Battery Clip

OthersCapacitor checkGenerating voltage checkResistance check

Water temperature sensorContinuity testDiode test

Car Measurement with SK-7682

Easy-to-grip handheldclampEasy-to-grip size with 196mm length and 180g weight. Can be used like an industrial tool.

Easy clamping even fornarrow conductorsEasy-to-clamp compact clamp jaws at φ19mm even for narrow conductors in car engine room.

Focused on High-Flexibility

φ19mm

ConductorDiameter

V / VHz / %

A / A Hz

Accuracy±1.5%rdg±3dgt40 to 200A201 to 400A±1.5%rdg±5dgt36 to 200A201 to 400A±0.2%rdg±2dgt±1.0%rdg±3dgt

±1.0%rdg±2dgt

±1.5%rdg±5dgt

±0.2%rdg±2dgt

±0.5%rdg±5dgt

±2.0%rdg±3dgt±4.0%rdg±3dgt

±2.0%rdg±5dgt±5.0%rdg±5dgt

Range40A

400A

40A

400A

5Hz to 1kHz400mV4V40V400V600V4V40V400V600V1Hz to 49.99kHz0% to 99.9%MAX / MIN, Peak Hold, Difference,Power-on Initialize (for DC Current measurement),Display Hold, Auto Power Off

MAXM I N

PEAKHOLD

AC/DC

VAC/DC

400ADISPHOLDDIFF

HzTRUERMSAPO

DUTY

%for Voltagemeasurement

for DC Currentmeasurement

AUTOZERO

FEATURES●Usable for Automotive Measurements.●Peak Current and Peak Voltage.●Max / Min and Difference Measurements.

DCVoltage

DCCurrent

ACCurrent

Frequency

Frequency

Duty Cycle

ACVoltage

Functions

SPECIFICATIONSDisplay

Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories

:

::::::::

4000 count LCD, Maximum reading 40503 times / sec Auto Rangingφ19mm Max. 1.5V R6P or AA Batteries (x 2) CATⅢ 300V and EMC196(H) x 59(W) x 30(D) mm180g100-57 Test Leads (x 1 set)940 Alligator Clips (x 1 set)1011 Carrying Case (x 1)1.5V R6P Batteries (x 2)

OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set948 Alligator Clips793 Coil-Type Contact Pin944 Test Pin946 Battery Clip φ19mm Max

Clam

p Meters

Insulation Testers / Earth TesterD

igital M

ultim

etersA

nalo

g Mu

ltitestersA

uto

mo

tive Testers

Oth

er Testers

Accesso

ries

Versatile Clamp Meter, Compactly Designed

SK-7718

Resistance

Functions

±1.5%rdg±5dgt±3.0%rdg±5dgt

±1.5%rdg±3dgt±3.0%rdg±3dgt

A / A Hz

V / V Hz・%

APOMAXM I N

PEAKHOLD

AC/DC

VAC/DC

1000ADISPHOLDDIFF

ΩTRUERMS

DUTY

%Hz

for DC Currentmeasurement

AUTOZERO

φ35mm

ConductorDiameter

FEATURES●AC / DC 1000A Measurements● "Power-On Initialize" (auto zero adjustment) for DCA.●MAX / MIN, Difference, Peak Hold●Dust-proof case is used to protect the tester from dust damage.

DCVoltage

ACVoltage

DCCurrent

ACCurrent

Frequency

Frequency

Duty Cycle

SPECIFICATIONSDisplay

Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories

:

::::::::

4000 count LCD, Maximum reading 99993 times / secAuto Rangingφ35mm Max. 9V 6F22 Battery (x 1)CATⅢ 600V and EMC193(H) x 60(W) x 34.5(D) mm300g 100-57 Test Leads (x 1 set)1012 Carrying Case (x 1)9V 6F22 Battery (x 1)

OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips948 Alligator Clips

793 Coil-Type Contact Pin944 Test Pin946 Battery Clip

DustProof

Simple WaterResistant

AC / DC Digital Clamp Meters

Continuity Test

Diode Test

Capacitance

Range400A

1000A

400A

1000A

1Hz to 1kHz4V40V400V600V400mV4V40V400V600V1Hz to49.99kHz10% to 90%400Ω4kΩ40kΩ400kΩ4MΩ40MΩ400Ω (Buzzer Sound : Approx. 50Ω or less)0 to 1.5VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF(±5.0%rdg±10dgt)Peak Hold, MAX / MIN, Difference,Power-on Initialize (for DC Current measurement),Display Hold, Auto Power OFF

Accuracy±1.5%rdg±5dgt400 to 600A601 to 1000A±1.5%rdg±3dgt400 to 600A601 to 1000A±0.2%rdg±2dgt

±1.0%rdg±5dgt (40Hz to 400Hz)

±1.0%rdg±3dgt

±0.2%rdg±2dgt

±2.0%rdg±2dgt±1.5%rdg±5dgt

±1.0%rdg±3dgt

±4.0%rdg±5dgt±6.0%rdg±5dgt

±5.0%rdg±5dgt

10

Starter current measurement

①Set the selector switch to

DC-A range.

②Press and hold Peak key to

enter Peak Hold mode.

③Clamp-on the minus cable of the car battery.

④Start the car engine.

⑤Read the measurement value on LCD.

Advantages of SK-7718

Display HoldCan freeze the readings on LCD. Useful for reading the

unstable measurement values.

DifferenceDisplay the relative value during the measurement.

Auto Power OffThe unit turns off automatically after 12 minutes of last

operation. Effective to conserve the battery life (cancelable).

MAX/MINDisplay the maximum and minumum values during the

measurement.

Dust & Drip ProofCan protect the unit from dust and water-drip affects.

Suitable for the various electric components testsAlternator ChargingCurrent MeasurementStarter Current MeasurementBattery Voltage Measurement

Other application : Water temperature sensor test, Continuity test, Diode test,

Noise-prevention capacifor check, Resistance check

MAX 1000A MeasurementUp to 1000A measurement for DC/AC current.

Applicable for high displacement vehicles.

Peak HoldFor starter current measurement. Can display the peak

current in the certain period of time.

Cla

mp

Met

ers

Insu

latio

n Te

ster

s / E

arth

Test

erD

igit

al M

ult

imet

ers

An

alo

g M

ult

ites

ters

Au

tom

oti

ve T

este

rsO

ther

Tes

ters

Acc

esso

ries

AC / DC Digital Clamp Meters

11

SK-7722

φ36mm

ConductorDiameter

Alternator Test - Charging Current & Generating Voltage

①Insert test lead plugs to the input terminals.

②Set the selector switch to DCA + DCV range.

⑤Start the engine, and clamp-on the B-terminal of the alternator.

③Contact test lead pins to the battery. Black to minus, red to plus.

④LCD shows the battery voltage when stopping the engine.

⑥Run up the engine around 2000 rpm. Load the maximum electricity by turning on the electric components, such as headlights.

※For charge control vehicles, alternator might not generate the power.

Simple WaterResistant

SK-7720 /SK-7722

PULSEWIDTH

MAXM I N

PEAKHOLD

2 Channel Measurements on Dual Display LCD and Oscilloscope Connection

AC/DC

VAC/DC

1000ADISPHOLDDIFF

DUTY

%HzΩ

TRUERMS

OUTPUT

SK-7722

OPTIONAL ACCESSORIES818-02 Temperature Probe817-03 to 817-25 Temperature Probes922 DC Adapter Cable (SK-7722)930 Output Cord for Recorder(SK-7722)

100-41 Test Lead Kit

FEATURES●Two different elements can be measured at once and

read on a bigger Dual Display LCD.●Analog Output Terminal for an Oscilloscope or Recorder (SK-7722).●Dust-proof case is used to protect the tester from dust damage.

Resistance

TemperatureFunctions

Range

400A / 1000A

Range400V650V

400A / 1000A

10.0Hz to 4000Hz0.0% to 99.9%1.0mS to 999.9mS

400V / 650V

10.0Hz to 4000Hz0.0% to 99.9%1.0mS to 999.9mS4000Ω20kΩ-30℃ to 150℃Peak Hold, MAX / MIN, Difference, Display Hold, Output Terminal (SK-7722)

Accuracy400.0A400 to 600A601 to 1000AAccuracy±1.0%rdg±3dgt±1.0%rdg±1dgt

400.0A400 to 600A601 to 1000A±0.5%rdg±1dgt±3.0%rdg±3dgt±0.5%rdg±3dgt±1.0%rdg±3dgt (50Hz to 60Hz)±1.5%rdg±3dgt (40Hz to 400Hz)±0.5%rdg±1dgt±3.0%rdg±3dgt±0.5%rdg±3dgt±1.0%rdg±3dgt±1.0%rdg±1dgt±1.0%rdg±3dgt

Range40V250V

Accuracy±1.0%rdg±3dgt±1.0%rdg±1dgt

40V / 250V±1.0%rdg±3dgt (50Hz to 60Hz)±1.5%rdg±3dgt (40Hz to 400Hz)

±1.5%rdg±3dgt±1.5%rdg±1dgt±3.0%rdg±3dgt

50Hz to 60Hz±1.5%rdg±3dgt±1.5%rdg±1dgt±3.0%rdg±3dgt

40Hz to 400Hz±2.5%rdg±3dgt±2.5%rdg±1dgt±4.0%rdg±3dgt

A + V

A + Hz

V + Hz

SK-7720 SK-7722

DCVoltage

ACVoltage

DCCurrent

ACCurrent

FrequencyDuty CyclePulse Width

FrequencyDuty CyclePulse Width

SPECIFICATIONSDisplaySampling Rate

Range SelectionConductor DiameterPower SupplyDimensionsWeightAccessories

::

::::::

4000 count LCD, Maximum reading 999915 times / sec. (each channel), 3.75 times / sec. for A+V measurements in ordinary mode.Auto Rangingφ36mm Max. 9V 6F22 or NEDA 1604 Battery (x 1)200(H) x 64(W) x 33(D) mm310g100-57 Test Leads (x 1 set)1007 Carrying Case (x 1), 9V 6F22 Battery (x 1)

DustProof

100-62 Test Lead Set940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin944 Test Pin946 Battery Clip

Two different elements can be measured at once and read on a bigger Dual Display LCD

Temperare check of air conditioner outlet※818 -02 tempearture probe (option) required.

Starter current and battery voltage measurements

Alternator measurement : Charging current and generating voltage

Advantages of SK-7720 / 7722

Clam

p Meters

Insulation Testers / Earth TesterD

igital M

ultim

etersA

nalo

g Mu

ltitestersA

uto

mo

tive Testers

Oth

er Testers

Accesso

ries

12

FEATURES● For various automotive measurements.

Battery voltage / RPM* / Injection pulse width /Charging current for alternator (with optional clamp adapter) /Temperature

*Except for rotary engine, diesel engine, and vehicle equipped with MSD or MDI systems.

● Large LCD with backlight and bar graph.●Display hold, Auto power off functions.●Error input warning.●Equipped with holster and hard carrying case.

::

:::

:

:::

SPECIFICATIONSDisplaySampling Rate

Range SelectionPower SupplyFuse

CE Mark

Dimensions WeightAccessories

6000 count LCD (Numerical) 5 times / sec(Bargraph) 40 times / secAuto / Manual Ranging1.5V R03 or AAA Batteries (x 2)F20 (0.63A/500V) x 1 F32 (6.3A/500V) x 1 V : CATⅡ 1000V, uA/mA/A : CATⅡ 450Vand EMC 161(H) x 80(W) x 50(D) mm 340gHolster, 100-66 Test Leads (x 1 set)653 RPM Sensor (for Direct Ignition)654 RPM Sensor (for High Tension Code)818-02 Temperature Probe943 Alligator Clip, 1024 Carrying Case1.5V R03 Batteries (Installed) x 2Spare Fuses F20 (0.63A/500V) &F32 (6.3A/500V) x 1 each

Extremely versatile Automotive Digital Multimeter

KT-2021

Automotive Digital Multimeters

Range Resolution

Resolution

Resolution

Accuracy

Accuracy

Accuracy

: DC/AC 40A/400A: DC/AC 100mA/mV(40A Range) DC/AC 1A/mV(400A Range): ±1.5% to 7.0%rdg±0.5mV: 1.5V R6P or AA Batteries (x2): φ19mm Max. : CAT Ⅱ 300V, CATⅠ600V, class 2 and EMC : 180(H) x 43(W)) x 31(D)mm: 210g: 145cm

RangeOutput

AccuracyPower SupplyConductor DiameterCE Mark

Dimensions WeightCable length

For engine speed measurement of direct ignition engine that is equipped for the most of gas-powered car recently.

RPM Sensor(Accessories)

For engine speed measurement by clamping on the high tension cord.

RPM Sensor(Accessories)

OPTIONAL ACCESSORIES660 AC / DC Clamp Adapter817-03 to 817-25 Temperature Probes100-41 Test Lead Kit100-62 Test Lead Set944 Test Pin946 Battery Clip793 Coil-Type Contact Pin

Velcro tape tofix the sensor

KT-2021

Automotive DMM

Spark Plug

MODEL 654

Equipped with anUseful Carrying Case

AC/DC

VAC/DC

ABARGRAPH

APODISPHOLD

RNGHOLDHzΩ DUTY

%PULSEWIDTH

DWELLANGLERPM Error input

warning

DCVoltage

ACVoltage

DCCurrent

ACCurrent

Resistance

Functions

Accessories, Optional Accessories

The charge current of alternator can be measured just clamping.

AC / DC Clamp Adapter(Optional Accessories)

MODEL 653

Direct Ignition Coil

KT-2021

Automotive DMM

Velcro tape

±0.4%rdg±3dgt±0.3%rdg±3dgt

±0.4%rdg±3dgt

±0.7%rdg±3dgt±2.0%rdg±5dgt(50Hz to 500Hz)

±2.0%rdg±5dgt(50Hz to 500Hz)

±2.2%rdg±5dgt(50Hz to 500Hz)

±0.7%rdg±3dgt±0.5%rdg±3dgt±0.7%rdg±3dgt±0.5%rdg±3dgt±0.7%rdg±3dgt±0.5%rdg±3dgt±2.2%rdg±5dgt±2.0%rdg±5dgt±2.2%rdg±5dgt±2.0%rdg±5dgt±2.2%rdg±5dgt±1.2%rdg±5dgt

±0.5%rdg±6dgt

±0.5%rdg±3dgt

±0.8%rdg±4dgt±1.0%rdg±5dgt±1.5%rdg±5dgt

60mV600mV6V60V600V1000V60mV600mV6V60V600V

1000V

600μA6000μA60mA600mA6A10A600μA6000μA60mA600mA6A10A

600Ω6kΩ60kΩ600kΩ6MΩ60MΩ

Bargraph, Range Hold, Display Hold, Auto Power Off, Backlight,Error input warning

Range

Range

0.01mV0.1mV1mV10mV100mV1V0.01mV0.1mV1mV10mV100mV

1V

0.1μA1μA0.01mA0.1mA1mA10mA0.1μA1μA0.01mA0.1mA1mA10mA

0.1Ω1Ω10Ω100Ω1kΩ10kΩ

≒10MΩ,50pF

≒10MΩ,50pF

Voltage Drop

0.25mV /μA

2.5mV / mA

0.03V / A

0.25mV /μA

2.5mV / mA

0.03V / A

Open Circuit Voltage

0.45V DC

Input Impedance RangeFunction Accuracy

Frequency ±0.1%rdg±3dgt

10Hz to 10kHz

10Hz to 50kHz

45Hz to 1kHz

6V60V600V1000V

0.5V rms5V rms50V rms500V rms

Input Sensitivity

RangeFunction

IP-RPM240 to 20000RPM120 to 10000RPM60 to 5000RPM

RPM4RPM2RPM2-M

±0.2%rdg±20dgt

Accuracy

AccuracyRange

Diode Test±1.0%rdg±3dgt1.000V

Open Circuit Voltage : <1.6V DC

Test Current0.50mA

ResolutionRange

Temperature1°C1°F

-50℃ to 1000℃-58°F to 1832°F

Accuracy±0.5%rdg±3dgt ±0.5%rdg±6dgt

ResolutionRange

Capacitance

0.001μF0.01μF0.1μF1μF

6.000μF60.00μF600.0μF2000μF

Accuracy±2.0%rdg±5dgt

±3.5%rdg±5dgt

±4.0%rdg±5dgt

AccuracyRange±1.2°/krpm±1dgt0° to 360° 1,2,3,4,5,6,8,10,12

Selectable Number of Cylinders

IG-RPM60 to 20000RPM30 to 10000RPM15 to 5000RPM

RPM4RPM2RPM2-M

±0.2%rdg±20dgt

Dwell Angle

Buzzer Sound : Approx. 10 to 200Ω or lessContinuity Test

±0.04%/krpm/cyl±2dgt 0% to 100% 1,2,3,4,5,6,8,10,12Duty CycleAccuracyRange

±0.05ms±1dgt0.05ms to250.0ms

Fuel InjectionPulse Width

±0.04%/krpm±2dgt0% to 100%Duty Cycle

Cla

mp

Met

ers

Insu

latio

n Te

ster

s / E

arth

Test

erD

igit

al M

ult

imet

ers

An

alo

g M

ult

ites

ters

Au

tom

oti

ve T

este

rsO

ther

Tes

ters

Acc

esso

ries

13

Automotive Digital Multimeters

Motorcycle Multimeter

AC/DC

VAC/DC

ARNGHOLDΩ

SPECIFICATIONSDisplaySampling RateRange SelectionPower Supply FuseCE MarkDimensions WeightAccessories

:::::::::

2000 count LCD, Maximum Reading 1999 2 times / secAuto / Manual Ranging1.5V R6P or AA Batteries (x 2)F12 (0.3A / 250V) x 1, F18 (15A / 250V) x 1CATⅡ 300V and EMC160(H) x 75(W) x 34(D) mm 180g100-57 Test Leads (x 1 set) 650 RPM Sensor (x 1), 940 Alligator Clips (x 1 set) 995 Carrying Case (x 1), 1.5V R6P Batteries (x 2) Spare Fuses F12 (0.3A / 250V) &F18 (15A / 250V) x 1 each

DISPHOLD

OPTIONAL ACCESSORIES660 AC / DC Clamp Adapter100-41 Test Lead Kit100-62 Test Lead Set948 Alligator Clips

944 Test Pin946 Battery Clip793 Coil-Type Contact Pin

APSRPM

DCVoltage

ACVoltage

DCCurrent

ACCurrent

Functions

Resistance

Range Resolution Accuracy Input Impedance200mV2V20V200V300V

0.1mV1mV10mV100mV1V

±1.2%rdg±2dgt

≧100MΩ

≒11MΩ

≒10MΩ

RPM

Range Resolution Accuracy Sparks12000RPM6000RPM

10RPM ±2%rdg±10dgt1 spark / 1 revolution2 sparks / 1 revolution

2V20V200V300V

1mV10mV100mV1V

±2.3%rdg±7dgt≒11MΩ

≒10MΩ

Range Resolution Accuracy Voltage Drop20mA

20A

10μA

10mA

±1.0%rdg±4dgt0 to 10.00A±1.5%rdg±2dgt10.01 to 20A ±2.5%rdg±4dgtt

≦0.5V

<0.5V

20mA

20A

10μA

10mA

±2.0%rdg±8dgt0 to 10.00A±2.0%rdg±7dgt10.01 to 20A±3.0%rdg±10dgt

<0.5V

Range Resolution Accuracy Test Current

Range Resolution Test Current

200Ω2kΩ20kΩ200kΩ2MΩ20MΩOpen Circuit Voltage : approx. ≦0.43V

0.1Ω1Ω10Ω100Ω1kΩ10kΩ

±1.5%rdg±4dgt

±1.8%rdg±4dgt±5.0%rdg±4dgt

≦0.4mA≦0.2mA≦30μA≦3μA≦0.3μA≦0.03μA

Range Hold, Display Hold, Auto Power Save

Continuity Test 2kΩ (Buzzer Sound : Approx. 500Ω or less)

Diode Test 2VOpen Circuit Voltage : ≦1.7V

1mV ≦0.6mA

FEATURES●RPM, 20mA and 20A DC / AC, and Continuity Tests. (Non-usable for Harley-Davidson V-twin engine 45°angle)● 200A DC / AC measurements by optional 660 Clamp

Adapter.

OPTIONAL ACCESSORIES940 Alligator Clips948 Alligator Clips792R Straight Test Pin (Red)944 Test Pin

946 Battery Clip793 Coil-Type Contact Pin1026 Carrying Case

FEATURES●Current measurement up to AC / DC 400mA.●Penlight and backlight LCD.

SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyFuseCE MarkDimensions WeightAccessories

4000 count LCD 3 times / sec.Auto Ranging1.5V LR44 Battery (x 2)F22 (0.5A / 600V) x 1CATⅢ 600V and EMC 209(H) x 38(W) x 32(D) mm Approx. 110g (include battery)100-68 Test Lead (Black) (x 1)1.5V LR44 Batteries (x 2)780 Red Insulation Cap (x 1) 781 Test Lead Insulation Cap (Black) (x 1)

:::::::::

SK-6597

Improved probe tester with enhanced functions

SK-6597

AC/DC

VAC/DC

A APODISPHOLDHzΩ DUTY

%PEN

LIGHTMAXM I N DIFF

Digital Multimeters (Probe Tester)

Range400mV4V40V400V600V

4V40V400V600V1Hz to 100kHz0.0% to 99.9%Range40mA400mA40mA400mA10Hz to 100kHzRange400Ω4kΩ40kΩ400kΩ4MΩ40MΩOpen Circuit Voltage : ≒0.44V400Ω (Buzzer Sound : Approx. 50Ω or less)1VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF MAX / MIN, Display Hold, Difference, Auto Power Off,Penlight and Backlight

Resolution0.1mV1mV10mV100mV1V

1mV10mV100mV1V0.001 to 100Hz0.1%Resolution10μA100μA10μA100μA0.01 to 100HzResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ

Accuracy

50Hz to 500Hz

±1.5%rdg±5dgt

Accuracy

Accuracy

Input Impedance≧100MΩ≒11MΩ

≒10MΩ

≒11MΩ

≒10MΩ

Burden Voltage<0.1V<0.6V<0.1V<0.6V

Test Current≦0.2mA≦50μA≦5μA≦0.5μA

≦50nA

±0.5%rdg±3dgt

±1.0%rdg±3dgt

±1.0%rdg±2dgt

±1.5%rdg±7dgt

±0.2%rdg±2dgt

±0.2%rdg±2dgt±0.5%rdg±5dgt

±1.5%rdg±4dgt

±1.0%rdg±3dgt

±5.0%rdg±3dgt±7.0%rdg±3dgt

±5.0%rdg±3dgt

±5.0%rdg±10dgt

DCCurrent

AC Current40Hz to 500Hz

DCVoltage

ACVoltage

Resistance

Functions

Continuity Test

Capacitance

Diode Test

Frequency

Frequency

Duty Cycle

≦0.7mA

Advantages of SK-6597

Easy-to-usepen-type testerEasily to be tested in car engine room.

Penlight andbacklight LCDBrightly i l luminate test points and display even in the dark place.

Current measurementCan measure up to 400mA AC/DC.

Easy-to-read large LCD (compared to the existing model)

Clear buzzer soundEasy-to-hear buzzer sound even in noisy conditions.

Replaceable Test Pin and Test LeadEasy replacement without any tools.

・Screw-in type Test Pin ・Plug-in type Test Lead

Clam

p Meters

Insulation Testers / Earth TesterD

igital M

ultim

etersA

nalo

g Mu

ltitestersA

uto

mo

tive Testers

Oth

er Testers

Accesso

ries

14

Resolution100μV1mV10mV100mV/1V1mV10mV/100mV1V0.001 to 100Hz0.1%Resolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ

Input Impedance≧100MΩ≒11MΩ

≒10MΩ

≒11MΩ

≒10MΩ

Test Current≦0.2mA≦50μA≦5μA≦0.5μA

≦50nA

≦0.7mA

OPTIONAL ACCESSORIES940 Alligator Clips948 Alligator Clips792R Red Straight Test Pin

944 Test Pin946 Battery Clip793 Coil-Type Contact Pin

FEATURES●Smart Design for Easy of Use.● Fully line-upped function for useful measurements.●MAX / MIN, and Difference Measurements are available.

DCVoltage

ACVoltage

Resistance

Functions

SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyCE MarkDimensions WeightAccessories

::::::::

4000 count LCD 3 times / sec.Auto Ranging3V CR2032 Battery (x 1)CATⅢ 600V and EMC 179(H) x 28(W) x 20(D) mm 60g100-52 Test Leads (x 1), 1006 Carrying Case (x 1)3V CR2032 Battery (x 1)

Multi-Functional and Versatile Probe Tester

AC/DC

V APODISPHOLD

MAXM I N DIFF

DUTY

%HzΩ

Digital Multimeters (Probe Tester)

FrequencyDuty Cycle

Continuity Test

Diode Test

Capacitance

Range400mV4.0V40V400V/600V4.0V40V/400V600V1Hz to 100kHz0 to 99.9%Range400Ω4.0kΩ40kΩ400kΩ4.0MΩ40MΩOpen Circuit Voltage : ≒0.44V

400Ω (Buzzer Sound : Approx. 60Ω or less)

1VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF (±5.0%rdg±10dgt)MAX / MIN, Difference, Display Hold, Auto Power Off

Accuracy

±0.5%rdg±3dgt

±1.0%rdg±3dgt

±1.5%rdg±5dgt

±0.2%rdg±2dgt±0.5%rdg±5dgtAccuracy±1.5%rdg±4dgt

±1.0%rdg±3dgt

±5.0%rdg±3dgt±7.0%rdg±3dgt

±5.0%rdg±3dgt

For Hybrid and Electric vehicles maintenances

SK-3502AC/DC

VDISPHOLD

DATAMEMO APSCOMP

125V200MΩ

250V2000MΩ

500V2000MΩ

1000V2000MΩ Ω

LOW

Digital Insulation Tester

SPECIFICATIONSDisplaySampling RatePower SupplyFuseCE MarkDimensionsWeightAccessories

::::::::

4000 count LCD, Maximum reading 40002 times / sec 1.5V R6P or AA Batteries (x 8)F22 (0.5A / 600V) x 1CATⅣ 600V CLASSⅡand EMC120(H) x 130(W) x 70(D) mm600g100-61 Test Leads (x 1 set), 945B Black Alligator Clip (x 1)1016 Carrying Case (x 1), 1.5V RW6P Batteries (x 8)Spare Fuse F22 (0.5A / 600V) x 1 (built-in)

SimpleDust Proof

SimpleWater Resistant

OPTIONAL ACCESSORIES766B Black Test Prod (with 767B Black Test Pin)940R Red Alligator Clip948R Red Alligator Clip

125V 250V 500V 1000V200MΩ

5MΩ0.200 to 10 MΩ

0 to 0.199 MΩ, 10.01 to 200.0 MΩ

2000MΩ50MΩ

0.200 to 100 MΩ

0 to 0.199 MΩ, 100.1 to 2000 MΩ

±3%rdg±4dgt

±5%rdg±5dgt

Comparator, Data memory, Timer, Live wire warning, Safety lock, High voltage warning, Automatic discharge,Zero-ohm adjustment, Backlight, Display hold, Auto power save

20.00Ω

200mA or more

DCV / ACV fixed (0V to 600V)

±3%rdg±5dgt

6V or more

±3%rdg±5dgtApprox. 660kΩ

400.0Ω

Approx. 10mA

AUTO (10V to 600V)

Rated Test Voltage (DC)Max. Effective ReadingCenter Reading1st effective rangeAccuracy2nd effective range

AccuracyDisplay Range (Auto-ranging)Accuracy (After 0Ω Adjustment)Measurement CurrentOpen Circuit VoltageRangeAccuracyInput Resistance

InsulationResistance

LowResistance

AC / DCVoltage

Functions

Car Measurement with SK-3502

Insulation Resistance Testfor Hybrid VehibleWhy measuring this?Checking insulated condition of motor or cable is essential for hybrid vehicles to prevent electric shock accident caused by leakage of high-voltage circuit.

① Insert test leads and alligator clips to the input tereminals.②Set function switch to

500V.

⑤Clip the metal part of the vehicle with the black alligator clip to get the grounding.

③Detach service plug.④Remove inverter cover,

and detach motor cable and generator cable from the inverter.

⑥Press Measure key with contacting the test pin on the terminal.

⑦Read the measurement value on LCD.

Cla

mp

Met

ers

Insu

latio

n Te

ster

s / E

arth

Test

erD

igit

al M

ult

imet

ers

An

alo

g M

ult

ites

ters

Au

tom

oti

ve T

este

rsO

ther

Tes

ters

Acc

esso

ries

15

Focusing on Easy of Use Digital Tachometer

SK-8401 DIGITAL TACHOMETERFEATURES●Quick and Easy Measurement.●Measurable with Various Types of Engines. (except for rotary engine, diesel engine, and vehicle

equipped with MSD or MDI systems.)

SPECIFICATIONSDisplayPower Supply CE MarkDimensions WeightAccessories

::::::

Maximum Reading 9999 1.5V R6P or AA Batteries (x 2)EMC test passed148(H) x 83(W) x 33(D) mm 180g653 RPM Sensor (x 1)995 Carrying Case (x 1)1.5V R6P (AA) batteries x 2

RPM

OPTIONAL ACCESSORIES650 RPM Sensor (for High Tension Cord)

rpmRange100 to 9999 rpmDisplay Hold, Auto Power Off

Resolution1 rpm

Accuracy±0.2%rdg±10rpm

Maximum. Input10000 rpm

DISPHOLD APO

Digital Tachometer

Functions

Quick and Easy Measurement

Measurement of Direct Ignition Engine

Use 653 RPM Sensor (provided)

Sensor head is fixable by using velcro tape attached.

Measurement of High Tension CodeType Engine

Use 650 RPM Sensor (option)

MODEL 653

Direct ignition coil

Velcro tape

SHIFT DH

SK-8401

DISPLAYHOLD POWER

1 2 HI(1Sec<)

DIGITALTACHOMETER

Spark Plug

MODEL 650

SHIFT DH

SK-8401

DISPLAYHOLD POWER

1 2 HI(1Sec<)

DIGITALTACHOMETER

O2 Sensor Checker

Deterioration level of O2 sensor can be checked easily by bar-graph

FEATURES●Deterioration level of O2 sensor can be checked easily

by bar-graph●Rich, Lean, Average voltages and Cycle are displayed

respectively.●Simulated sensor signal output is available.

SK-8402 O2 SENSOR CHECKER

APODISPHOLD

DCVoltage

Functions

Resolution

1mV

10mV

Accuracy0 to 200mV:±1.5%rdg±10dgt 201 to 999mV:±1.5%rdg±5dgt ±1.5%rdg±5dgt

Range

999mV

6.00VDisplay mode changing, Simulation Test, Display Hold, Auto Power Off

Connection image

Bar-Graph Display

mV

RICH

TEST Z

APO

GOOD CHECK BAD

CHECKreplacement

recommended( )

mV

RICH

TEST Z

APO

GOOD CHECK BAD

BADreplacement

required( )GOOD

(No problem)

mV

RICH

TEST Z

GOOD CHECK BAD

APO

SK-8402

ECU in vehicle sideO2sensor

Test lead

Check harness

Connecting couplerfor O2 sensor side

Connecting couplerfor ECU side

POWER(1Sec<)

S (1Sec<)

(Test)

O2 SENSOR CHECKER

DHT5T1Z

RICH LEANDISPLAYTEST

SK-8402

TEST SEL

C

mV

AUTO DH

RICH

TEST Z T1 T5 S

AVGLEAN

APO

GOOD CHECK BAD

Yello

w

Yello

w

Blac

kBl

ack

Red

Red

Black Red

DC

V

SPECIFICATIONSDisplay

Sampling Rate

Range SelectionPower SupplyCE Mark Dimensions WeightAccessories

:

:

::::::

(Numerical) 999 count LCD,(Bargraph) 13 segments500 times/second(LCD : 1 time/second in stand-by mode)Auto Ranging1.5V R6P or AA Batteries (x 2)EMC test passed148(H) x 83(W) x 33(D) mm 220g100-65 Test Lead (x 1 set) 911Check Harness (x 1)947B Black Alligator Clip (x 1)795 Test Pins: Red & Black (x 1 set)1030 Carrying case (x 1)1.5V R6P Batteries (x 2)

SK-8402 is the O2 Sensor Checker for the O2 sensor of Zirconia, Titania 1V/5V. SK-8402 can not check deterioration judgment of A/F (air-fuel ratio) Sensor or Rear O2 Sensor.

Deterioration level of O2 sensor can be checked easily by bar-graph.

Clam

p Meters

Insulation Testers / Earth TesterD

igital M

ultim

etersA

nalo

g Mu

ltitestersA

uto

mo

tive Testers

Oth

er Testers

Accesso

ries

16

Clamp Meters Index

Model

Display Counts

Conductor Diameter

DC Current

AC Current

DC Voltage

AC Voltage

Resistance

Frequency

Duty Cycle

Pulse Width

Continuity Test

Diode Test

Capacitance

Temperature

True RMS

Auto Ranging

Manual Ranging

MAX / MIN

Average

Peak Hold

Range Hold

Difference

Display Hold

Power-On Initialize

Comparator

Low Pass Filter

Output Terminal

External Power Supply

Dust Proof & Simple Water Resistant

Auto Power Save (Off)

4000

φ27mm

40A

400A

-40A

400A

--

400mV

4V

40V

400V

600V

4V

40V

400V

600V

400Ω4kΩ

40kΩ400kΩ4MΩ

40MΩ●●-●●●-●●---●-●● ●*1

-----●

4000

φ27mm

40A

400A

-40A

400A

--

400mV

4V

40V

400V

600V

4V

40V

400V

600V

400Ω4kΩ

40kΩ400kΩ4MΩ

40MΩ●●-●●●--●-●---●● ●*1

-----●

4000

φ19mm

40A

400A

-40A

400A

--

400mV

4V

40V

400V

600V

4V

40V

400V

600V

------●●-----●●-●-●-●● ●*1

-----●

AC / DC Digital Clamp Meters

*1 : for DC Current measurement

4000

φ35mm

400A

1000A

-400A

1000A

--

400mV

4V

40V

400V

600V

4V

40V

400V

600V

400Ω4kΩ40kΩ

400kΩ4MΩ40MΩ●●-●●●-●●-●-●-●● ●*1

----●●

SK-7718

4000

φ35mm

400A

1000A

-400A

1000A

--

400mV

4V

40V

400V

600V

4V

40V

400V

600V

400Ω4kΩ40kΩ

400kΩ4MΩ40MΩ●●-●●●--●-●--●●●●*1

----●●

Cla

mp

Met

ers

Insu

latio

n Te

ster

s / E

arth

Test

erD

igit

al M

ult

imet

ers

An

alo

g M

ult

ites

ters

Au

tom

oti

ve T

este

rsO

ther

Tes

ters

Acc

esso

ries

17

Clamp Meters Index

Model

Display Counts

Conductor Diameter

DC Current

AC Current

DC Voltage

AC Voltage

Resistance

Frequency

Duty Cycle

Pulse Width

Continuity Test

Diode Test

Capacitance

Temperature

True RMS

Auto Ranging

Manual Ranging

MAX / MIN

Average

Peak Hold

Range Hold

Difference

Display Hold

Power-On Initialize

Comparator

Low Pass Filter

Output Terminal

External Power Supply

Dust Proof & Simple Water Resistant

Auto Power Save (Off)

AC / DC Digital Clamp Meters AC Digital Clamp Meters

4000

φ36mm

400A

1000A

-400A

1000A

--

400V

650V

---

400V

650V

--

4000Ω20kΩ----●●●---●●●-●-●-●●-----●-

SK-7720

4000

φ36mm

400A

1000A

-400A

1000A

--

40V

250V

---

40V

250V

--

4000Ω20kΩ----●●●---●●●-●-●-●●---●●●-

SK-7722

4000

φ27mm

---

40A

300A

-------------------------●------●------●

4000

φ27mm

---

40A

400A

--

400mV

4V

40V

400V

600V

4V

40V

400V

600V

400Ω4kΩ40kΩ

400kΩ4MΩ40MΩ●●-●●●-●●-●---●●------●

4000

φ55mm

400A

2000A

-400A

2000A

--

400mV

4V

40V

400V

600V

4V

40V

400V

600V

400Ω4kΩ40kΩ

400kΩ4MΩ40MΩ●●-●●●-●●●●-●●●● ●*1

----●●

SK-7708

*1 : for DC Current measurement

Clam

p Meters

Insulation Testers / Earth TesterD

igital M

ultim

etersA

nalo

g Mu

ltitestersA

uto

mo

tive Testers

Oth

er Testers

Accesso

ries

18

Clamp Meters Index

Model

Display Counts

Conductor Diameter

DC Current

AC Current

DC Voltage

AC Voltage

Resistance

Frequency

Duty Cycle

Pulse Width

Continuity Test

Diode Test

Capacitance

Temperature

True RMS

Auto Ranging

Manual Ranging

MAX / MIN

Average

Peak Hold

Range Hold

Difference

Display Hold

Power-On Initialize

Comparator

Low Pass Filter

Output Terminal

External Power Supply

Dust Proof & Simple Water Resistant

Auto Power Save (Off)

2000

φ26mm

---2A

20A

200A

400A

200mV

2V

20V

200V

600V

2V

20V

200V

600V

200Ω2kΩ

20kΩ200kΩ2MΩ

20MΩ---●●--- ●*2

------●------●

AC Digital Clamp Meters

*2 : Two-ranges auto for ACA. *3 : mA / A : switch selection

2000

φ42mm

---2A

20A

200A

600A

200mV

2V

20V

200V

600V

2V

20V

200V

600V

200Ω2kΩ20kΩ

200kΩ2MΩ20MΩ---●●--- ●*2

------●------●

AC Leakage Clamp Meters

4000

φ24mm

---

40mA

400mA

40A

100A

-----

400V

600V

---------------- ●*3

------●-

●(with Vibration)

●---●

SK-7820

4000

φ40mm

---

40mA

400mA

40A

100A

-----

400V

600V

---------------- ●*3

------●-

●(with Vibration)

●---●

SK-7825

4000

φ27mm

---

40A

400A

--

400mV

4V

40V

400V

600V

4V

40V

400V

600V

400Ω4kΩ

40kΩ400kΩ4MΩ

40MΩ●●-●●●--●-●---●●------●

Cla

mp

Met

ers

Insu

latio

n Te

ster

s / E

arth

Test

erD

igit

al M

ult

imet

ers

An

alo

g M

ult

ites

ters

Au

tom

oti

ve T

este

rsO

ther

Tes

ters

Acc

esso

ries

19

SK-7660

MAXM I N

PEAKHOLD

Handy-size Clamps with Efficient Functions

AC/DC

VAC/DC

400A

DIFF

DUTY

%HzΩ

FEATURES● 15 measurement functions in one small package.● "Power-On Initialize" (auto zero adjustment) in DCA.●Rubber-molded rotary switch and trigger.●Easy-to-clamp compact & beaked clamp head even for

narrow conductors.●True RMS and peak hold (SK-7660), MAX/MIN (SK-7661)

Accuracy±1.5%rdg±3dgt40 to 200A201 to 300A301 to 400A±1.5%rdg±5dgt (50/60Hz)40 to 200A201 to 300A301 to 400A±0.2%rdg±2dgt±1.0%rdg±3dgt

±1.0%rdg±2dgt

±1.5%rdg±5dgt (40 to 400Hz)

±0.2%rdg±2dgt

±1.0%rdg±3dgt±1.5%rdg±5dgt±0.7%rdg±3dgt±1.2%rdg±5dgt±3.0%rdg±5dgt±1.5%rdg±5dgt±5.0%rdg±5dgt±1.5%rdg±5dgt

±5.0%rdg±5dgt

±1.5%rdg±5dgt±3.0%rdg±3dgt±4.0%rdg±3dgt

±2.0%rdg±3dgt (50/60Hz)±4.0%rdg±5dgt (50/60Hz)±5.0%rdg±5dgt (50/60Hz)

*Frequency Characteristic (40 to 400Hz) : 40A Range (0.5 to 9A) add 1.5% (10 to 40A) add 0.5% 400A Range add 1.0%

SK-7660 SK-7661

OPTIONAL ACCESSORIES940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin

A / A Hz

V / VHz / %

V / VHz / %

A / A Hz

Range40A

400A

40A

400A

5Hz to 1kHz400mV4V40V400V600V4V40V400V600V5Hz to 49.99kHz5% to 95%400Ω4kΩ40kΩ400kΩ4MΩ40MΩ400ΩBuzzer Sound : Approx. 50Ω or less0 to 1.5VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF(±5.0%rdg±10dgt)Peak Hold (SK-7660), MAX / MIN (SK-7661), Difference, Power-on Initialize (for DC Current measurement),Display Hold, Auto Power OFF

for DC Currentmeasurement

AUTOZERO APODISP

HOLD

SK-7660

TRUERMS

Accuracy±1.5%rdg±3dgt40 to 200A201 to 400A±1.5%rdg±5dgt36 to 200A201 to 400A±0.2%rdg±2dgt±1.0%rdg±3dgt

±1.0%rdg±2dgt

±1.5%rdg±5dgt

±0.2%rdg±2dgt

±0.5%rdg±5dgt

±2.0%rdg±3dgt±4.0%rdg±3dgt

±2.0%rdg±5dgt±5.0%rdg±5dgt

Range40A

400A

40A

400A

5Hz to 1kHz400mV4V40V400V600V4V40V400V600V1Hz to 49.99kHz0% to 99.9%MAX / MIN, Peak Hold, Difference,Power-on Initialize (for DC Current measurement),Display Hold, Auto Power Off

MAXM I N

PEAKHOLD

Focused on High-Flexibility

AC/DC

VAC/DC

400ADISPHOLDDIFF

HzTRUERMSAPO

DUTY

%for Voltagemeasurement

φ27mm

ConductorDiameter

φ19mm

ConductorDiameter

for DC Currentmeasurement

AUTOZERO

FEATURES●Usable for Automotive Measurements.●Peak Current and Peak Voltage.●Max / Min and Difference Measurements.

DCVoltage

ACVoltage

DCCurrent

ACCurrent*

Frequency

Frequency

Duty Cycle

Resistance

Continuity Test

Functions

DCVoltage

DCCurrent

ACCurrent

Frequency

Frequency

Duty Cycle

ACVoltage

Functions

AC / DC Digital Clamp Meters

SPECIFICATIONSDisplay

Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories

:

::::::::

4000 count LCD, Maximum reading 40503 times / secAuto Rangingφ27mm Max. 1.5V R03 or AAA Batteries (x 2)CATⅢ 300V, CATⅡ 600V and EMC 170(H) x 58(W) x 27(D)mm 160g100-63 Test Leads (x 1 set)1015 Carrying Case (x 1)1.5V R03 Batteries (x 2)

SPECIFICATIONSDisplay

Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories

:

::::::::

4000 count LCD, Maximum reading 40503 times / sec Auto Rangingφ19mm Max. 1.5V R6P or AA Batteries (x 2) CATⅢ 300V and EMC196(H) x 59(W) x 30(D) mm180g100-57 Test Leads (x 1 set)940 Alligator Clips (x 1 set)1011 Carrying Case (x 1)1.5V R6P Batteries (x 2)

OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set948 Alligator Clips793 Coil-Type Contact Pin

Diode Test

Capacitance

Clam

p Meters

Insulation Testers / Earth TesterD

igital M

ultim

etersA

nalo

g Mu

ltitestersA

uto

mo

tive Testers

Oth

er Testers

Accesso

ries

20

SK-7720

φ36mm

ConductorDiameter

Simple WaterResistant

AC / DC Digital Clamp Meters

SK-7720 /SK-7722

PULSEWIDTH

MAXM I N

PEAKHOLD

2 Channel Measurements on Dual Display LCD and Oscilloscope Connection

AC/DC

VAC/DC

1000ADISPHOLDDIFF

DUTY

%HzΩTRUERMS

OUTPUT

SK-7722

Resistance

TemperatureFunctions

Range

400A / 1000A

Range400V650V

400A / 1000A

10.0Hz to 4000Hz0.0% to 99.9%1.0mS to 999.9mS

400V / 650V

10.0Hz to 4000Hz0.0% to 99.9%1.0mS to 999.9mS4000Ω20kΩ-30℃ to 150℃Peak Hold, MAX / MIN, Difference, Display Hold, Output Terminal (SK-7722)

Accuracy400.0A400 to 600A601 to 1000AAccuracy±1.0%rdg±3dgt±1.0%rdg±1dgt

400.0A400 to 600A601 to 1000A±0.5%rdg±1dgt±3.0%rdg±3dgt±0.5%rdg±3dgt±1.0%rdg±3dgt (50Hz to 60Hz)±1.5%rdg±3dgt (40Hz to 400Hz)±0.5%rdg±1dgt±3.0%rdg±3dgt±0.5%rdg±3dgt±1.0%rdg±3dgt±1.0%rdg±1dgt±1.0%rdg±3dgt

Range40V250V

Accuracy±1.0%rdg±3dgt±1.0%rdg±1dgt

40V / 250V±1.0%rdg±3dgt (50Hz to 60Hz)±1.5%rdg±3dgt (40Hz to 400Hz)

±1.5%rdg±3dgt±1.5%rdg±1dgt±3.0%rdg±3dgt

50Hz to 60Hz±1.5%rdg±3dgt±1.5%rdg±1dgt±3.0%rdg±3dgt

40Hz to 400Hz±2.5%rdg±3dgt±2.5%rdg±1dgt±4.0%rdg±3dgt

A + V

A + Hz

V + Hz

SK-7720 SK-7722

OPTIONAL ACCESSORIES818-02 Temperature Probe817-03 to 817-25 Temperature Probes922 DC Adapter Cable (SK-7722)

930 Output Cord for Recorder(SK-7722)

100-41 Test Lead Kit

FEATURES●Two different elements can be measured at once and

read on a bigger Dual Display LCD.●Analog Output Terminal for an Oscilloscope or Recorder (SK-7722).●Dust-proof case is used to protect the tester from dust damage.

DCVoltage

ACVoltage

DCCurrent

ACCurrent

FrequencyDuty CyclePulse Width

FrequencyDuty CyclePulse Width

SPECIFICATIONSDisplaySampling Rate

Range SelectionConductor DiameterPower SupplyDimensionsWeightAccessories

::

::::::

4000 count LCD, Maximum reading 999915 times / sec. (each channel), 3.75 times / sec. for A+V measurements in ordinary mode.Auto Rangingφ36mm Max. 9V 6F22 or NEDA 1604 Battery (x 1)200(H) x 64(W) x 33(D) mm310g100-57 Test Leads (x 1 set)1007 Carrying Case (x 1), 9V 6F22 Battery (x 1)

DustProof

100-62 Test Lead Set940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin

Versatile Clamp Meter, Compactly Designed

SK-7718

APOMAXM I N

PEAKHOLD

AC/DC

VAC/DC

1000ADISPHOLDDIFF

Ω

TRUERMS

DUTY

%Hz

SK-7718 SK-7719 SK-7718

RNGHOLD

for DC Currentmeasurement

AUTOZERO

φ35mm

ConductorDiameter

FEATURES●AC / DC 1000A Measurements● "Power-On Initialize" (auto zero adjustment) for DCA.●MAX / MIN, Difference, Peak Hold (SK-7718), and Range

Hold (SK-7719)●Dust-proof case is used to protect the tester from dust damage.

Functions

Continuity Test

Diode Test

Capacitance

Resistance

Accuracy±1.5%rdg±5dgt400 to 600A601 to 1000A±1.5%rdg±3dgt400 to 600A601 to 1000A±0.2%rdg±2dgt

±1.0%rdg±5dgt (40Hz to 400Hz)

±1.0%rdg±3dgt

±0.2%rdg±2dgt

±2.0%rdg±2dgt±1.5%rdg±5dgt

±1.0%rdg±3dgt

±4.0%rdg±5dgt±6.0%rdg±5dgt

±5.0%rdg±5dgt

±1.5%rdg±5dgt±3.0%rdg±5dgt

±1.5%rdg±3dgt±3.0%rdg±3dgt

Range400A

1000A

400A

1000A

1Hz to 1kHz4V40V400V600V400mV4V40V400V600V1Hz to49.99kHz10% to 90%400Ω4kΩ40kΩ400kΩ4MΩ40MΩ400Ω (Buzzer Sound : Approx. 50Ω or less)0 to 1.5VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF(±5.0%rdg±10dgt)Peak Hold (SK-7718), MAX / MIN, Difference,Power-on Initialize (for DC Current measurement),Range Hold (SK-7719), Display Hold,Auto Power OFF

A / A Hz

V / V Hz・% DC

Voltage

ACVoltage

DCCurrent

ACCurrent

Frequency

Frequency

Duty Cycle

SPECIFICATIONSDisplay

Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories

:

::::::::

4000 count LCD, Maximum reading 99993 times / secAuto Rangingφ35mm Max. 9V 6F22 Battery (x 1)CATⅢ 600V and EMC193(H) x 60(W) x 34.5(D) mm300g 100-57 Test Leads (x 1 set)1012 Carrying Case (x 1)9V 6F22 Battery (x 1)

OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips

948 Alligator Clips793 Coil-Type Contact Pin

DustProof

Simple WaterResistant

SK-7718

Cla

mp

Met

ers

Insu

latio

n Te

ster

s / E

arth

Test

erD

igit

al M

ult

imet

ers

An

alo

g M

ult

ites

ters

Au

tom

oti

ve T

este

rsO

ther

Tes

ters

Acc

esso

ries

21

RNGHOLD

MAXM I N

PEAKHOLD

Powerful for Every Measurement

AC/DC

VAC/DC

2000ADISPHOLDDIFF

DUTY

%HzΩ

SK-7708FEATURES● "Power-On Initialize" (auto zero adjustment) for DCA.●Peak Hold, MAX / MIN measurements.●Dust-proof case is used to protect the tester from dust damage.

TRUERMSAPS

A / A Hz

V / V Hz・%

Range

400A

2000A

400A2000A1Hz to 4.999kHz

4V / 40V / 400V / 600V400mV / 4V / 40V / 400V / 600V1Hz to 100kHz0.1% to 99.9%400Ω4kΩ / 40kΩ / 400kΩ4MΩ40MΩ400ΩBuzzer Sound : Approx. 50Ω or less0 to 1.5VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μFMAX / MIN, Peak Hold, Difference, Power-on Initialize (for DC Current measurement), Range Hold, Display Hold, Auto Power Save

Accuracy

0 to 1000A1001A or more

±1.5%rdg±5dgt

±0.2%rdg±2dgt40Hz to 400Hz±1.5%rdg±5dgt ±1.2%rdg±3dgt ±0.2%rdg±2dgt±2.0%rdg±2dgt±1.5%rdg±5dgt±1.0%rdg±3dgt±3.0%rdg±4dgt±5.0%rdg±7dgt±1.5%rdg±5dgt

±5.0%rdg±5dgt

±5.0%rdg±10dgt

401Hz to 1KHz±3.0%rdg±5dgt

50Hz to 60Hz±1.5%rdg±5dgt ±1.5%rdg±5dgt ±3.0%rdg±5dgt

40Hz to 1kHz±3.0%rdg±5dgt ±3.0%rdg±5dgt

for DC Currentmeasurement

AUTOZERO

φ55mm

ConductorDiameter

Resistance

Functions

DC Voltage

ACVoltage

DCCurrent

ACCurrent

FrequencyDuty Cycle

Frequency

AC / DC Digital Clamp Meters

DustProof

SPECIFICATIONSDisplay

Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories

:

::::::::

4000 count LCD, Maximum reading 51203 times / secAuto / Manual Rangingφ55mm Max. 9V 6F22 Battery (x 1)CATⅢ 600V and EMC250(H) x 92(W) x 39(D) mm500g 100-57 Test Leads (x 1 set)1007 Carrying Case (x 1)9V 6F22 Battery (x 1)

OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin

Simple WaterResistant

Continuity Test

Diode Test

Capacitance

Pocket-sized Clamp Meter

AC

300A APODISPHOLD

FEATURES●Simple operation.●Strong and beaked Clamp Head against twists.●AUTO POWER OFF : turns off automatically after

12 minutes. ● Full Auto Ranging up to 300A AC.●DISPLAY HOLD Function.●With Carrying Case.

Accuracy

±1.8%rdg±5dgt

Range40A300A

Display Hold, Auto Power OFF

φ27mm

ConductorDiameter

ACCurrent

Functions

AC Digital Clamp Meters

SPECIFICATIONSDisplay

Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories

:

::::::::

4000 count LCD, Maximum reading 40002.5 times / secAuto Rangingφ27mm Max. 3V CR2032 Battery (x 1)CATⅢ 300V and EMC 150(H) x 52(W) x 24(D)mm 110g1004 Carrying Case (x 1)3V CR2032 Battery (x 1)

Clam

p Meters

Insulation Testers / Earth TesterD

igital M

ultim

etersA

nalo

g Mu

ltitestersA

uto

mo

tive Testers

Oth

er Testers

Accesso

ries

22

AC Digital Clamp Meters

OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin

SK-7602

MAXM I N

Multi-functional Handy Clamp with Long Battery Life

AC/DC

VAC

400A

APODISPHOLDDIFF

DUTY

%HzΩ

FEATURES●290-hours long time measurement (SK-7603, with alkaline

cells) ● 13 measurement functions in one small package.●Rubber-molded rotary switch and trigger.●Easy-to-clamp compact & beaked clamp head even for

narrow conductors.● True RMS (SK-7660), MAX/MIN and Difference measurement.

Accuracy±1.5%rdg±5dgt (50Hz/60Hz)±3.0%rdg±5dgt (40Hz to 400Hz)±0.2%rdg±2dgt±1.0%rdg±3dgt

±1.0%rdg±2dgt

±1.5%rdg±5dgt (40Hz to 400Hz)

±0.2%rdg±2dgt

±2.0%rdg±3dgt±1.5%rdg±5dgt

±0.7%rdg±3dgt

±1.2%rdg±5dgt±3.0%rdg±5dgt

SK-7602

TRUERMS

A / Hz

V / VHz / %

Range40A400A5Hz to 1kHz400mV4V40V400V600V4V40V400V600V5Hz to49.99kHz5% to 95%400Ω4kΩ40kΩ400kΩ4MΩ40MΩ

Continuity Test, Diode Test, Capacitance

MAX / MIN, Difference, Display Hold,Auto Power OFF

OPTIONAL ACCESSORIES940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin

φ27mm

ConductorDiameter

SPECIFICATIONSDisplaySampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories

:::::::::

4000 count LCD, Maximum reading 40503 times / secAuto Rangingφ27mm Max. 1.5V R03 or AAA Batteries (x 2)CATⅢ 300V, CATⅡ 600V and EMC 171(H) x 58(W) x 27(D)mm 140g100-63 Test Leads (x 1 set)1015 Carrying Case (x 1)1.5V R03 Batteries (x 2)

DCVoltage

ACVoltage

ACCurrent

Frequency

Frequency

Duty Cycle

Resistance

Functions

OtherMeasurements

Easy & Useful

Easy - to - ClampSK-7602 / 7603's compact and beaked clamp heads assure easy clamping even for narrow conductors.

Avoid YourFingers SlipsSK-7602 / 7603 are always fit on your hand. Double-Molding Rubbers on a Function Switch and a Trigger avoid your fingers slips during operation.

Test LeadHolderFixable Test Lead on the side of SK-7602 / 7603 by inserting its hook into the holder socket. Useful for Voltage, Resistance, Capacitance Measurements, Continuity and Diode Tests.

φ27mm MAX

High Quality Clamp Meter that contains DMM functions

AC/DC

VAC

400A

APODISPHOLD

Ω

FEATURES●Round Clamp Head opens two ways at slant position

assures accuracy and easy use.●Easy Operation with Rotary Switch.●Wide Measurement Ranges.

2A20A200A400A

Accuracy±5.0%rdg±10dgt±2.0%rdg±7dgt

±1.5%rdg±7dgt

Accuracy

±1.0%rdg±5dgt

±0.5%rdg±2dgt±0.8%rdg±2dgt±1.0%rdg±2dgt±1.5%rdg±5dgt±3.0%rdg±5dgt±5.0%rdg±5dgt

Range

2A/20A

200A/400A

Range

2V/20V/200V/600V

200mV2V/20V/200V600V200Ω/2kΩ/20kΩ/200kΩ2MΩ20MΩ

Continuity Test, Diode Test

Display Hold, Auto Power OFF

φ26mm

ConductorDiameter

SPECIFICATIONSDisplaySampling RateRange SelectionConductor DiameterPower SupplyDimensionsWeightAccessories

::::::::

2000 count LCD, Maximum reading 19993 times / secAuto Ranging(two-ranges auto for ACA)φ26mm Max. 1.5V LR-44 Batteries (x 2) 171(H) x 72(W) x 35(D) mm180g 100-57 Test Leads (x 1 set)983 Carrying Case (x 1)1.5V LR-44 Batteries (x 2)

DCVoltage

ACVoltage

ACCurrent

Resistance

Functions

OtherMeasurements

Cla

mp

Met

ers

Insu

latio

n Te

ster

s / E

arth

Test

erD

igit

al M

ult

imet

ers

An

alo

g M

ult

ites

ters

Au

tom

oti

ve T

este

rsO

ther

Tes

ters

Acc

esso

ries

23

Advantages of SK-7820 / 7825

FEATURES●Wide range from 40mA to 100A AC.●Vibration and buzzer comparator convenient in noisy

surroundings. ● Low pass filter (cutoff 150Hz or more)● 100-hours continuous measurement (with alkaline cells)●Rubber-molded rotaty switch and trigger neatly fit in

your hand.

OPTIONAL ACCESSORIES940 Alligator Clips948 Alligator Clips

793 Coil-Type Contact Pin

SPECIFICATIONSDisplaySampling RateRange SelectionConductor DiameterPower SupplyCE Mark Dimensions

WeightAccessories

:::::::

::

4000 count LCD, Maximum reading 40502 times / sec Auto Ranging (mA / A : switch selection)SK-7820:φ24mm Max., SK-7825:φ40mm Max.1.5V (L) R03 or AAA Batteries (x 2) CATⅢ 300V, CATⅡ 600V and EMCSK-7820:168(H) x 58(W) x 27(D) mmSK-7825:184(H) x 58(W) x 27(D) mmSK-7820:170g, SK-7825:180g 100-63 Test Leads (x 1 set)1020 Carrying Case (x 1), 1.5V LR03 Batteries (x 2)

SK-7825

The World's First Vibration Alert Comparator Installed

AC

VAPODISP

HOLD

SK-7820/SK-7825

LPFCOMP

ACCurrent

Functions

ACVoltage

Accuracy (50/60Hz)0.10mA to 1.00mA1.01mA or more0.10A to 1.00A1.01A or more40.1A to 80.0A80.1A to 100.0A5.0V to 10.0V10.1V or more

Filter ON (50/60Hz)

add ±1.0%rdg±3dgt

add ±1.0%rdg±3dgt

Frequency Characteristic (40 to 400Hz)

add ±1.0%rdg±3dgt

add ±1.0%rdg±3dgt

±1.0%rdg±7dgt±1.0%rdg±5dgt±2.0%rdg±7dgt±2.0%rdg±5dgt±2.0%rdg±5dgt±4.0%rdg±5dgt ±2.0%rdg±7dgt±2.0%rdg±5dgt

Range

40mA / 400mA

40A

100A

400V / 600V

Vibration alert comparator, Low pass filter, Display Hold, Auto Power OFF

AC

100A

φ40mm

ConductorDiameter

SK-7825

φ24mm

ConductorDiameter

SK-7820

Vibration Alert ComparatorSK-7820 / 7825 incorporate Comparator Function in ~mA range. Buzzer sounds and vibrates if measuring value exceeds the setting value. Even in noisy surroundings, that can drown out the buzzer sound, vibration helps your comparator measurement. (Vibration alert is cancelable.)

Two-types-of Clamp HeadSK-7820's small clamp head assures easy clamping even for narrow conductors. SK-7825's large clamp head is suitable for thick conductors' measurement like 3-phase 3-wire system.

SK-7820

φ24mm Max φ40mm Max

SK-7820 SK-7825

AC Digital Clamp Meters

High Quality Clamp Meter that contains DMM functions

AC/DC

VAC

600A

APODISPHOLD

Ω

2A20A200A600A

Accuracy±5.0%rdg±10dgt ±2.0%rdg±7dgt

±1.5%rdg±7dgt

Accuracy

±1.0%rdg±5dgt

±0.5%rdg±2dgt±0.8%rdg±2dgt±1.0%rdg±2dgt±1.5%rdg±5dgt±3.0%rdg±5dgt±5.0%rdg±5dgt

Range

2A/20A

200A/600A

Range

2V/20V/200V/600V

200mV2V/20V/200V600V200Ω/2kΩ/20kΩ/200kΩ2MΩ20MΩ

Continuity Test, Diode Test

Display Hold, Auto Power OFF

φ42mm

ConductorDiameter

FEATURES●Round Clamp Head opens two ways at slant position

assures accuracy and easy use.●Easy Operation with Rotary Switch.●Wide Measurement Ranges.

SPECIFICATIONSDisplaySampling RateRange SelectionConductor DiameterPower SupplyDimensionsWeightAccessories

::::::::

2000 count LCD, Maximum reading 19993 times / secAuto Ranging (two-ranges auto for ACA)φ42mm Max. 1.5V LR-44 Batteries (x 2) 183(H) x 78(W) x 35(D) mm210g 100-57 Test Leads (x 1 set)983 Carrying Case (x 1)1.5V LR-44 Batteries (x 2)

DCVoltage

ACVoltage

ACCurrent

Resistance

OtherMeasurementsFunctions

OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin

AC Leakage Clamp Meters

Clam

p Meters

Insulation Testers / Earth TesterD

igital M

ultim

etersA

nalo

g Mu

ltitestersA

uto

mo

tive Testers

Oth

er Testers

Accesso

ries

24

Insulation Testers Index

Model

Digital / Analog

Measurement Ranges

Insulation Resistance

Low Resistance

DC Voltage

AC Voltage

Continuity Test

Comparator

Data Memory

Timer

Live wire warning

Safety lock

High voltage warning

Automatic discharge

Display hold

Zero-ohm adjustment

Auto power save

Digital

4-Ranges

50V

125V

250V

500V

●●●-●●●●●●●●●●

SK-3500

Digital

4-Ranges

125V

250V

500V

1000V

●●●-●●●●●●●●●●

SK-3502

Analog

2-Ranges

250V

500V

----●---●-------

SK-3002

Analog

2-Ranges

500V

1000V

----●---●-------

SK-3003

Multi-Functional Insulation Testers

SK-3002/SK-3003/SK-3005

AC

V250V

50MΩ

SK-3002

500V100MΩ

SK-3002 / 3005

500V1000MΩ

SK-3003

1000V2000MΩ

SK-3003 / 3005

250V 500V 500V 1000VSK-3002 SK-3003

50MΩ0.05 to 50MΩ

1MΩ

100MΩ0.1 to 100MΩ

2MΩ

1000MΩ1 to 1000MΩ

20MΩ

2000MΩ2 to 2000MΩ

50MΩ

500V 1000VSK-3005

100MΩ0.1 to 100MΩ

2MΩ

2000MΩ1 to 2000MΩ

40MΩInfinite Scale : ±10% of Rated Voltage Center Scale : Over 90% of Rated Voltage

First effective range : ±5% of reading valueSecond effective range : ±10% of reading value

Zero and Infinite : ±0.7% of scale length0 to 600V

±3% of full scale valueApprox. 3 minutes

by Battery Scale on BATT. CHECK position

Rated Test Voltage (DC)Max. Effective ReadingEffective rangeCenter ScaleTerminal VoltageAccuracy

RangeAccuracy

Load

Power SourceL side E side

OFF

How to measure Volume Resistance Insulation Resistance Measurements

SK-3003

Analog Insulation Testers

SPECIFICATIONSPower SupplyDimensionsWeightAccessories

::::

1.5V R6P or AA Batteries (x 8)165(H) x 100(W) x 45(D) mm540g100-34 Test Leads (x 1 set), 939 Test Pin (x 1)978 Carrying Case (x 1), 1.5V R6P Batteries (x 8)

InsulationResistance

ACVoltage

TimerBattery Check

CoreConductor

Insulator

LeadCoating

Before measurement, make sure that the line (circuit) or object under test is not live.

OPTIONAL ACCESSORIES940R Red Alligator Clip

Cla

mp

Met

ers

Insu

latio

n Te

ster

s / E

arth

Test

erD

igit

al M

ult

imet

ers

An

alo

g M

ult

ites

ters

Au

tom

oti

ve T

este

rsO

ther

Tes

ters

Acc

esso

ries

25

SK-3502

50V 125V 250V 500V 125V 250V 500V 1000V

Compact, But Powerfull. Versatile 4-Range Insulation Tester

SK-3500/SK-3502FEATURES●Wide Range of Insulation Measurement with Enhanced Safety.●Comparator Function.●Data Memory Function. (up to 100 data)

AC/DC

VDISPHOLD

DATAMEMO APSCOMP

50V200MΩ

SK-3500

125V200MΩ

250V2000MΩ

500V2000MΩ

1000V2000MΩ

SK-3502

ΩLOW

SK-3500 SK-3502

200MΩ5MΩ

0.200 to 10 MΩ

0 to 0.199 MΩ, 10.01 to 200.0 MΩ

2000MΩ50MΩ

0.200 to 100 MΩ

0 to 0.199 MΩ100.1 to 2000 MΩ

200MΩ5MΩ

0.200 to 10 MΩ

0 to 0.199 MΩ, 10.01 to 200.0 MΩ

2000MΩ50MΩ

0.200 to 100 MΩ

0 to 0.199 MΩ, 100.1 to 2000 MΩ

±3%rdg±4dgt

±5%rdg±5dgt

±3%rdg±4dgt

±5%rdg±5dgt

Comparator, Data memory, Timer, Live wire warning, Safety lock, High voltage warning, Automatic discharge, Zero-ohm adjustment, Backlight, Display hold, Auto power save

Common to SK-3500 / SK-350220.00Ω

200mA or more

DCV / ACV fixed (0V to 600V)

±3%rdg±5dgt

6V or more

±3%rdg±5dgtApprox. 660kΩ

400.0Ω

Approx. 10mA

AUTO (10V to 600V)

Digital Insulation Testers

SPECIFICATIONSDisplaySampling RatePower SupplyFuseCE MarkDimensionsWeightAccessories

::::::::

4000 count LCD, Maximum reading 40002 times / sec 1.5V R6P or AA Batteries (x 8)F22 (0.5A / 600V) x 1CATⅣ 600V CLASSⅡand EMC120(H) x 130(W) x 70(D) mm600g100-61 Test Leads (x 1 set), 945B Black Alligator Clip (x 1)1016 Carrying Case (x 1), 1.5V RW6P Batteries (x 8)Spare Fuse F22 (0.5A / 600V) x 1 (built-in)

SimpleDust Proof

SimpleWater Resistant

OPTIONAL ACCESSORIES766B Black Test Prod (with 767B Black Test Pin)940R Red Alligator Clip948R Red Alligator Clip

Rated Test Voltage (DC)Max. Effective ReadingCenter Reading1st effective rangeAccuracy2nd effective range

Accuracy

Display Range (Auto-ranging)Accuracy (After 0Ω Adjustment)Measurement CurrentOpen Circuit VoltageRangeAccuracyInput Resistance

InsulationResistance

LowResistance

AC / DCVoltage

Functions

Advantages of SK-3500 / 3502

Wide Digital DisplayBargraph LCD (with backlight)Wide bargraph scale that can confirm measurement values on sight like an analog meter. Backlight is helpful for easy reading even in dark areas.

Data Memory FunctionUp to 100 data can be saved in internal memory together with their measured date and time. (for Insulation Resistance and Low Resistance)

Comparator FunctionBuzzer sounds and "HIGH" or "LOW" light up if measuring value exceeds or falls below the threshold. (for Insulation Resistance and Low Resistance)

Example) Memorize 100MΩ measured under 1000V.

Selectable by SELECT Key

MeasuredTime

MeasuredDate

MeasuredYear

Example) When setting a buzzer on 10MΩ or lower.

Set a buzzer on10MΩ or lower.

Measure 4MΩ

Measure 40MΩ

V

flashesand buzzer sounds.

lights up

26

Digital Multimeters Index

Model

Display Counts

Bargraph

DC Voltage

AC Voltage

DC Current

AC Current

Resistance

Frequency

Duty Cycle

Continuity Test

Diode Test

Capacitance

Temperature

True RMS

Auto Ranging

Manual Ranging

MAX / MIN

Range Hold

Difference

Display Hold

Comparator

Current by Clamp Adapter

Dust Proof & Simple Water Resistant

Backlight

Penlight

Auto Power Save (Off)

4000

400mV

4V

40V

400V

1000V

4V

40V

400V

750V

40mA

400mA

4A

20A

40mA

400mA

4A

20A

400Ω

4kΩ

40kΩ

400kΩ

4MΩ

40MΩ

●-

4000

400mV

4V

40V

400V

1000V

4V

40V

400V

750V

400μA

4000μA

40mA

400mA

4A

20A

400μA

4000μA

40mA

400mA

4A

20A

400Ω

4kΩ

40kΩ

400kΩ

4MΩ

40MΩ

●-

4000

400mV

4V

40V

400V

600V

400mV

4V

40V

400V

600V

400μA

4000μA

40mA

400mA

4A

10A

400μA

4000μA

40mA

400mA

4A

10A

400Ω

4kΩ

40kΩ

400kΩ

4MΩ

40MΩ

4000

400mV

4V

40V

400V

600V

400mV

4V

40V

400V

600V

40mA

400mA

10A

40mA

400mA

10A

400Ω

4kΩ

40kΩ

400kΩ

4MΩ

40MΩ

Clam

p Meters

Insulation Testers / Earth TesterD

igital M

ultim

etersA

nalo

g Mu

ltitestersA

uto

mo

tive Testers

Oth

er Testers

Accesso

ries

Cla

mp

Met

ers

Insu

latio

n Te

ster

s / E

arth

Test

erD

igit

al M

ult

imet

ers

An

alo

g M

ult

ites

ters

Au

tom

oti

ve T

este

rsO

ther

Tes

ters

Acc

esso

ries

27

Digital Multimeters Index

Model

Display Counts

Bargraph

DC Voltage

AC Voltage

DC Current

AC Current

Resistance

Frequency

Duty Cycle

Continuity Test

Diode Test

Capacitance

Temperature

True RMS

Auto Ranging

Manual Ranging

MAX / MIN

Range Hold

Difference

Display Hold

Comparator

Current by Clamp Adapter

Dust Proof & Simple Water Resistant

Backlight

Penlight

Auto Power Save (Off)

4000

-400mV

4V

40V

400V

600V

-4V

40V

400V

600V

--

40mA

400mA

----

40mA

400mA

----

400Ω4kΩ

40kΩ400kΩ4MΩ

40MΩ●●●●●--●-●-●●---●●●

4000

●400mV

4V

40V

400V

1000V

-400mV

4V

40V

400V

750V

-40mA

400mA

4A

20A

--

40mA

400mA

4A

20A

--

400Ω4kΩ

40kΩ400kΩ4MΩ

40MΩ●-●●---●●●●●●-●●--●

4000

400mV

4V

40V

400V

600V

400mV

4V

40V

400V

600V

400μA

4000μA

40mA

400mA

10A

400μA

4000μA

40mA

400mA

10A

400Ω

4kΩ

40kΩ

400kΩ

4MΩ

40MΩ

SK-4033SK-6597

4000

-400mV

4.0V

40V

400V

600V

-4.0V

40V

400V

600V

-------

-----

400Ω4.0kΩ40kΩ

400kΩ4.0MΩ40MΩ●●●●●--●-●-●●-----●

4000

400mV

4V

40V

400V

600V

400mV

4V

40V

400V

600V

400μA

4000μA

40mA

400mA

10A

400μA

4000μA

40mA

400mA

10A

400Ω

4kΩ

40kΩ

400kΩ

4MΩ

40MΩ

SK-4035

Clam

p Meters

Insulation Testers / Earth TesterD

igital M

ultim

etersA

nalo

g Mu

ltitestersA

uto

mo

tive Testers

Oth

er Testers

Accesso

ries

28

Digital Multimeters Index

Model

Display Counts

Bargraph

DC Voltage

AC Voltage

DC Current

AC Current

Resistance

Frequency

Duty Cycle

Continuity Test

Diode Test

Capacitance

Temperature

True RMS

Auto Ranging

Manual Ranging

MAX / MIN

Range Hold

Difference

Display Hold

Comparator

Current by Clamp Adapter

Dust Proof & Simple Water Resistant

Backlight

Penlight

Auto Power Save (Off)

4000

-400mV

4.0V

40V

400V

600V

-4.0V

40V

400V

600V

-------

-----

400Ω4.0kΩ40kΩ

400kΩ4.0MΩ40MΩ●●●●●--●●●●●●-----●

2000

-200mV

2V

20V

200V

600V

-2V

20V

200V

600V

-------

-----

200Ω2kΩ20kΩ

200kΩ2MΩ20MΩ--●●---●----●-----●

4000

-400mV

4V

40V

400V

500V

-400mV

4V

40V

400V

500V

------

-----

400Ω4kΩ40kΩ

400kΩ4MΩ40MΩ--●●---●----------●

KU-1199

Cla

mp

Met

ers

Insu

latio

n Te

ster

s / E

arth

Test

erD

igit

al M

ult

imet

ers

An

alo

g M

ult

ites

ters

Au

tom

oti

ve T

este

rsO

ther

Tes

ters

Acc

esso

ries

Digital Multimeters (Handy Type)

High Cost Performance, Temperature Measurement (KU-2602)

AC/DC

VAC/DC

AAPODISP

HOLDRNGHOLDDIFF

DUTY

%HzΩ

FEATURES● Temperature Measurement. (Temperature Probe is provided) (KU-2602)● Tilt Stand and Test Lead Holder on rear side.●Display Hold, Range Hold functions.●Auto Power Off, Reset functions.

OPTIONAL ACCESSORIES660 AC / DC Clamp Adapter817-03 to 817-25 Temperature Probes (KU-2602)100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin995 Carrying Case

SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyFuse

CE MarkDimensions WeightAccessories

:::::

::::

4000 count LCD2 times / secAuto / Manual Ranging1.5V R6P or AA Batteries (x 2)F14 (0.5A / 250V) x 1F17 (10A / 250V) x 1CATⅡ600V, CATⅢ 300V compliant155(H) x 75(W) x 29(D) mm 180gHolster, 100-50 Test Leads (x 1 set)818-02 Temperature Probe (x 1)(KU-2602)1.5V R6P Batteries (x2 & spare)Spare Fuses F14 (0.5A/250V) & F17 (10A/250V) x 1 each

DCVoltage

ACVoltage

DCCurrent

ACCurrent

Resistance

Temperature

Functions

KU-2600/KU-2602

Input Impedance≧100MΩ

≒10MΩ

≒10MΩ

Voltage Drop200mV2.2V MAX200mV200mV2.2V MAX200mV

KU-2600

KU-2602

KU-2602

DCVoltage

ACVoltage

DCCurrent

ACCurrent

Resistance

Frequency

Continuity Test

Duty Cycle

Diode Test

Capacitance

Frequency

Continuity Test

Duty Cycle

Diode Test

Capacitance

Functions

Standard hand-heldDigital MultimeterEasy to carry around to any measuring field.

Color-codedRange SwitchHelps your range selecting with color-coding switches.

Example:Press SELECT key (colored yellow) to select AC or DC in mA or A measuring ranges.

Test-Lead-FixableRubber HolsterNo need to f ind the place to set the Digital Multimeter in measuring field.KU-2600/2602 al lows quick measurement holding the unit in hand.

29

Features of KU-2600/KU-2602

Range400mV4V/40V400V/600V400mV4V/40V400V600VRange40mA400mA10A40mA400mA10A400Ω/4kΩ40kΩ/400kΩ4MΩ/40MΩOpen Circuit Voltage : Approx. 0.44V9.999Hz to9.999MHz0% to99.9%

400Ω (Buzzer Sound : Approx. 50Ω or less)

4VOpen Circuit Voltage : ≦1.5V0.1nF to 40nF / 40nF to 40μF / 40μF to 200μF (±3.0%rdg±5dgt)Difference, Range Hold, Display Hold, Auto Power Off, Reset

Resolution100μV1mV/10mV100mV/1V0.1mV1mV/10mV100mV1VResolution10μA100μA10mA10μA100μA10mA0.1Ω/1Ω10Ω/100Ω1kΩ/10kΩ

0.01Hz to1.0kHz

0.1%

Accuracy

±0.5%rdg±4dgt

±1.0%rdg±4dgt±4.0%rdg±8dgt

±1.2%rdg±5dgt

±1.5%rdg±5dgtAccuracy

±2.0%rdg±4dgt

±2.5%rdg±4dgt±2.5%rdg±5dgt

±3.0%rdg±5dgt

±1.0%rdg±3dgt

±1.8%rdg±3dgt

±0.2%rdg±1dgt

±0.2%rdg±2dgt

±5.0%rdg±3dgt

Range400mV4V40V400V600V400mV4V40V400V600VRange400μA/4000μA40mA/400mA4A/10A400μA/4000μA40mA/400mA4A/10ARange400Ω4kΩ40kΩ400kΩ4MΩ40MΩOpen Circuit Voltage : Approx. 0.44VRange0℃ to 40℃-20℃ to 200℃200℃ to 500℃9.999Hz to9.999MHz0.1% to99.9%

400Ω (Buzzer Sound : Approx. 60Ω or less)

4VOpen Circuit Voltage : ≦1.5V4 / 40 / 400nF / 4 / 40 / 200μF (±2.0%rdg±5dgt)Difference, Range Hold, Display Hold, Auto Power Off, Reset

Resolution0.1mV1mV10mV100mV1V0.1mV1mV10mV100mV1VResolution0.1μA/1μA10μA/100μA1mA/10mA0.1μA/1μA10μA/100μA1mA/10mAResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ

Resolution

1℃

0.01Hz to1.0kHz

0.1%

Accuracy

±0.5%rdg±5dgt

±0.8%rdg±5dgt±1.2%rdg±5dgt

±0.8%rdg±5dgt

±1.2%rdg±5dgtAccuracy

±1.5%rdg±5dgt

±2.0%rdg±5dgt

±2.0%rdg±5dgt

±2.5%rdg±5dgtAccuracy

±1.0%rdg±5dgt

±2.0%rdg±5dgt

Accuracy±3℃±0.75%rdg±3℃±1.5%rdg±3℃

±0.02%rdg±5dgt

±2%rdg±5dgt

±5.0%rdg±3dgt

Input Impedance>100MΩ≒11MΩ

≒10MΩ

≒11MΩ

≒10MΩ

Voltage Drop40mV/400mV70mV/700mV500mV/1.4V40mV/400mV70mV/700mV500mV/1.4VTest Current≦0.3mA≦40μA≦4μA≦0.4μA

≦40nA

SensorBuilt-in

External

Clam

p Meters

Insulation Testers / Earth TesterD

igital M

ultim

etersA

nalo

g Mu

ltitestersA

uto

mo

tive Testers

Oth

er Testers

Accesso

ries

Frequency

Digital Multimeters (Handy Type)

DCVoltage

ACVoltage

DCCurrent

Frequency

ACCurrent

Resistance

Functions

Range400mV4V40V400V1000V400mV4V40V400V750VRange40mA /400mA

4A / 20A

40mA /400mA

4A / 20A

Range400Ω4kΩ40kΩ400kΩ4MΩ40MΩOpen Circuit Voltage : ≦0.4V99.99Hz to999.9kHz400Ω (Buzzer Sound : Approx. 40Ω or less)2VOpen Circuit Voltage : ≦3.3VMAX / MIN, Difference, Range Hold, Display Hold, Auto Power Save

Resolution100μV1mV10mV100mV1V100μV1mV10mV100mV1VResolution

100μA

10mA

100μA

10mA

Resolution100mΩ1Ω10Ω100Ω1kΩ10kΩ

0.01Hz to100Hz

1mV

Accuracy

±0.5%rdg±2dgt

±0.8%rdg±1dgt

±2.0%rdg±7dgt

±1.5%rdg±5dgt

Accuracy

±1.2%rdg±2dgt

0 to 10.00A±2.0%rdg±2dgt10.01 to 20A ±2.5%rdg±4dgt

±2.5%rdg±5dgt

0 to 10.00A±2.5%rdg±5dgt10.01 to 20A±3.0%rdg±10dgtAccuracy±1.0%rdg±2dgt

±0.7%rdg±2dgt

±1.0%rdg±2dgt±2.0%rdg±2dgt

±0.3%rdg±3dgt(999.9Hz / 9.999kHz Range)

Input Impedance≧100MΩ≒11MΩ

≒10MΩ

≧100MΩ≒11MΩ

≒10MΩ

Voltage Drop40mV(40mA)400mV(400mA)

130mV(4A)350mV(10A)

40mV(40mA)400mV(400mA)

130mV(4A)350mV(10A)

Test Current≦0.5mA≦0.2mA≦40μA≦4μA≦0.4μA≦40nA

4000 Count DMM with Bargraph

AC/DC

VAC/DC

ARNGHOLD

ΩFEATURES● Large LCD with Bargraph.●Tough designed case with Dust-proof and

Water-resistant structure.

SPECIFICATIONSDisplay

Sampling Rate

Range SelectionPower SupplyFuseCE MarkDimensions WeightAccessories

:

:

:::::::

(Numerical) 4000 count LCD,Maximum Reading 9999(Bargraph) 40 segments(1 segment / 100 digits)(Numerical) 3 times / sec(Bargraph) 30 times / secAuto / Manual Ranging1.5V R6P or AA Batteries (x 2)F33 (15A / 1000V) x 1, F34 (2A / 1000V) x 1CAT Ⅱ 600V and EMC180(H) x 86(W) x 35(D) mm 320g100-57 Test Leads (x 1 set)1.5V R6P Batteries (x 2)

DISPHOLD

OPTIONAL ACCESSORIES660 AC / DC Clamp Adapter100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips

948 Alligator Clips793 Coil-Type Contact Pin995 Carrying Case

BARGRAPH

APSMAXM I N DIFF

Hz

DustProof

Simple WaterResistant

30

SK-6161

::

:::

:::

SPECIFICATIONSDisplaySampling Rate

Range SelectionPower SupplyFuse

Dimensions WeightAccessories

4000 count LCD 2.5 times / sec(except frequency duty cycle, capacitance measurements)Auto / Manual Ranging1.5V R6P or AA Batteries (x 2)F14 (0.5A / 250V) x 1 F16 (15A / 250V) x 1160(H) x 75(W) x 34(D) mm, 180g100-57 Test Leads (x 1 set)1020 Carrying Case1.5V R6P Batteries (x 2)Spare Fuses F14 (0.5A / 250V) &F16 (15A / 250V) x 1 each

Advantages of SK-6161/ 6163

Easy-to-readlarge LCD

Colored range switchfor easy operation

Range400mV4V40/400/1000V4V40/400/750V5Hz to 20kHz10 to 90%Range400μ/4000μA*40m/400mA4A

20A

400μ/4000μA*40m/400mA4A

20A

5Hz to 1kHzRange400Ω4kΩ40kΩ400kΩ4MΩ40MΩOpen Circuit Voltage : Approx. 0.44V

400Ω (Buzzer Sound : Approx. 60Ω or less)

1VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF (±5.0%rdg±10dgt)Difference (SK-6163), Range Hold, Display Hold (SK-6163), Auto Power Save

Resolution0.1mV1mV10m/100m/1V1mV10m/100m/1V0.01 to 10Hz0.1%Resolution0.1μ/1μA0.01m/0.1mA1mA

10mA

0.1μ/1μA0.01m/0.1mA1mA

10mA

0.01 to 1HzResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ

Accuracy±0.5%rdg±2dgt

±0.5%rdg±1dgt

±1%rdg±5dgt

±0.2%rdg±2dgt±2%rdg±2dgtAccuracy±1%rdg±1dgt±1%rdg±1dgt±1.5%rdg±2dgt0~10.00A ±1.5%rdg±2dgt10.01~20.00A ±2.5%rdg±4dgt±1.5%rdg±5dgt±1.5%rdg±5dgt±2%rdg±7dgt0~10.00A ±2%rdg±7dgt10.01~20.00A ±3%rdg±7dgt±0.2%rdg±2dgtAccuracy±0.8%rdg±3dgt

±0.8%rdg±2dgt

±2%rdg±3dgt±3%rdg±3dgt

±5.0%rdg±3dgt

Input Impedance>100MΩ≒11MΩ≒10MΩ≒11MΩ≒10MΩ

Voltage Drop0.11mV/μA2mV/mA30mV/A

30mV/A

0.11mV/μA2mV/mA30mV/A

30mV/A

Test Current≦0.3mA≦40μA≦4μA≦0.4μA

≦40nA

Easy-to-read Large LCD with 20mm high numerals

AC/DC

VAC/DC

A Ω

FEATURES●Easy-to-read Large LCD with 20mm high numerals.● 300 hours continuous operation with only two 1.5V Batteries.● 20A AC / DC Measurements.

SK-6163SK-6163 SK-6163

* 400μA / 4000μA range is SK-6163 only.

SK-6163

APSDISPHOLD

RNGHOLDDIFF

DUTY

%Hz

940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin

OPTIONAL ACCESSORIES660 AC / DC Clamp Adapter100-41 Test Lead Kit100-62 Test Lead Set

DCVoltage

ACVoltage

DCCurrent

ACCurrent

Functions

Resistance

Frequency

Continuity Test

Duty Cycle

Diode Test

Capacitance

Continuity Test

Diode Test

Cla

mp

Met

ers

Insu

latio

n Te

ster

s / E

arth

Test

erD

igit

al M

ult

imet

ers

An

alo

g M

ult

ites

ters

Au

tom

oti

ve T

este

rsO

ther

Tes

ters

Acc

esso

ries

Resolution100μV1mV10mV100mV/1V1mV10mV/100mV1V0.001 to 100Hz0.1%Resolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ

Input Impedance≧100MΩ≒11MΩ

≒10MΩ

≒11MΩ

≒10MΩ

Test Current≦0.2mA≦50μA≦5μA≦0.5μA

≦50nA

≦0.7mA

OPTIONAL ACCESSORIES940 Alligator Clips948 Alligator Clips

792R Red Straight Test Pin793 Coil-Type Contact Pin

FEATURES●Smart Design for Easy of Use.● Fully line-upped function for useful measurements.●MAX / MIN, and Difference Measurements are available.

DCVoltage

ACVoltage

Resistance

Functions

SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyCE MarkDimensions WeightAccessories

::::::::

4000 count LCD 3 times / sec.Auto Ranging3V CR2032 Battery (x 1)CATⅢ 600V and EMC 179(H) x 28(W) x 20(D) mm 60g100-52 Test Leads (x 1), 1006 Carrying Case (x 1)3V CR2032 Battery (x 1)

31

Multi-Functional and Versatile Probe Tester

AC/DC

VAPODISP

HOLDMAXM I N DIFF

DUTY

%HzΩ

FrequencyDuty Cycle

Continuity Test

Diode Test

Capacitance

Range400mV4.0V40V400V/600V4.0V40V/400V600V1Hz to 100kHz0 to 99.9%Range400Ω4.0kΩ40kΩ400kΩ4.0MΩ40MΩOpen Circuit Voltage : ≒0.44V

400Ω (Buzzer Sound : Approx. 60Ω or less)

1VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF (±5.0%rdg±10dgt)MAX / MIN, Difference, Display Hold, Auto Power Off

Accuracy

±0.5%rdg±3dgt

±1.0%rdg±3dgt

±1.5%rdg±5dgt

±0.2%rdg±2dgt±0.5%rdg±5dgtAccuracy±1.5%rdg±4dgt

±1.0%rdg±3dgt

±5.0%rdg±3dgt±7.0%rdg±3dgt

±5.0%rdg±3dgt

OPTIONAL ACCESSORIES940 Alligator Clips948 Alligator Clips792R Straight Test Pin (Red)793 Coil-Type Contact Pin1026 Carrying Case

FEATURES●Current measurement up to AC / DC 400mA.●Penlight and backlight LCD.

SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyFuseCE MarkDimensions WeightAccessories

4000 count LCD 3 times / sec.Auto Ranging1.5V LR44 Battery (x 2)F22 (0.5A / 600V) x 1CATⅢ 600V and EMC 209(H) x 38(W) x 32(D) mm Approx. 110g (include battery)100-68 Test Lead (Black) (x 1)1.5V LR44 Batteries (x 2)780 Red Insulation Cap (x 1) 781 Test Lead Insulation Cap (Black) (x 1)

:::::::::

Improved probe tester with enhanced functions

SK-6597

AC/DC

VAC/DC

AAPODISP

HOLD

HzΩ DUTY

%PEN

LIGHTMAXM I N DIFF

Digital Multimeters (Probe Tester)

Range400mV4V40V400V600V

4V40V400V600V1Hz to 100kHz0.0% to 99.9%Range40mA400mA40mA400mA10Hz to 100kHzRange400Ω4kΩ40kΩ400kΩ4MΩ40MΩOpen Circuit Voltage : ≒0.44V400Ω (Buzzer Sound : Approx. 50Ω or less)1VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF MAX / MIN, Display Hold, Difference, Auto Power Off,Penlight and Backlight

Resolution0.1mV1mV10mV100mV1V

1mV10mV100mV1V0.001 to 100Hz0.1%Resolution10μA100μA10μA100μA0.01 to 100HzResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ

Accuracy

50Hz to 500Hz

±1.5%rdg±5dgt

Accuracy

Accuracy

Input Impedance≧100MΩ≒11MΩ

≒10MΩ

≒11MΩ

≒10MΩ

Burden Voltage<0.1V<0.6V<0.1V<0.6V

Test Current≦0.2mA≦50μA≦5μA≦0.5μA

≦50nA

±0.5%rdg±3dgt

±1.0%rdg±3dgt

±1.0%rdg±2dgt

±1.5%rdg±7dgt

±0.2%rdg±2dgt

±0.2%rdg±2dgt±0.5%rdg±5dgt

±1.5%rdg±4dgt

±1.0%rdg±3dgt

±5.0%rdg±3dgt±7.0%rdg±3dgt

±5.0%rdg±3dgt

±5.0%rdg±10dgt

DCCurrent

AC Current40Hz to 500Hz

DCVoltage

ACVoltage

Resistance

Functions

Continuity Test

Capacitance

Diode Test

Frequency

Frequency

Duty Cycle

≦0.7mA

Advantages of SK-6597

Penlight andbacklight LCDBrightly i l luminate test points and display even in the dark place.

Current measurementCan measure up to 400mA AC/DC.

Easy-to-use pen-type testerHandheld tester like an industrial tool.

Easy-to-read large LCD (compared to the existing model)

Clear buzzer soundEasy-to-hear buzzer sound even in noisy conditions.

Easy-to-use large Test Lead

Gold-plated Test Pin and Test Lead Tip

Replaceable Test Pin and Test LeadEasy replacement without any tools.

・Screw-in type Test Pin ・Plug-in type Test Lead

Clam

p Meters

Insulation Testers / Earth TesterD

igital M

ultim

etersA

nalo

g Mu

ltitestersA

uto

mo

tive Testers

Oth

er Testers

Accesso

ries

32

Digital Multimeters (All-in-one DMM)

Range400mV4.0V40V400V/600V4.0V40V/400V600V1Hz to 100kHz0 to 99.9%Range400Ω4.0kΩ40kΩ400kΩ4.0MΩ40MΩOpen Circuit Voltage : ≒0.44V

400Ω (Buzzer Sound : Approx. 60Ω or less)

1VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF (±5.0%rdg±10dgt)MAX / MIN, Difference, Range Hold, Display Hold,Auto Power Save

Resolution100μV1mV10mV100mV/1V1mV10mV/100mV1V0.001 to 100Hz0.1%Resolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ

Accuracy

±0.5%rdg±3dgt

±1.0%rdg±3dgt

±1.5%rdg±5dgt

±0.2%rdg±2dgt±0.5%rdg±5dgtAccuracy±1.5%rdg±4dgt

±1.0%rdg±3dgt

±3.0%rdg±3dgt±7.0%rdg±3dgt

±5.0%rdg±3dgt

Input Impedance≧100MΩ≒11MΩ

≒10MΩ

≒11MΩ

≒10MΩ

Test Current≦0.2mA≦50μA≦5μA≦0.5μA

≦50nA

≦0.7mA

DCVoltage

ACVoltage

Resistance

Functions

OPTIONAL ACCESSORY940 Alligator Clips948 Alligator Clips

793 Coil-Type Contact Pin

SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyCE MarkDimensions WeightAccessories

::::::::

4000 count LCD 3 times / secAuto / Manual Ranging3V CR2032 Battery (x 1)CATⅢ 300V and EMC118(H) x 78(W) x 16(D) mm 110g3V CR2032 Battery (x 1)

High-Precision DMM

AC/DC

V

APSDISPHOLD

MAXM I N

RNGHOLDDIFF

DUTY

%HzΩ

FEATURES●Multi-functional Card Type DMM comparable to Large

Multi meter.●Very Useful for Any Measurement Conditions.

Output Terminals

SK-4035

Digital Multimeters (Bench-Top DMM)

OPTIONAL ACCESSORIES660 AC/DC Clamp Adapter100-41 Test Lead Kit100-62 Test Lead Set

940 Alligator Clip948 Alligator Clip793 Coil-Type Contact Pin

Bench-Type DMM with Output Terminals

FEATURES●Output terminals to connect and control the external

inspection equipments.●SK-4035 assures the accurate measurementby True RMS.●Comparator function useful for the quality check in the

production line.●Easy-to-use simple lay out keys Easy-to-read large display.

AC/DC

VAC/DC

ATRUERMS

RNGHOLDΩ COMP

Range400mV4V40/400/600V400mV4V40/400/600VRange400μA/4000μA40mA400mA10A400μA/4000μA40mA400mA10ARange400Ω4kΩ40kΩ400kΩ4MΩ40MΩComparator, Range Hold

Resolution0.1mV1mV10mV/100mV/1V0.1mV1mV10mV/100mV/1VResolution0.1μA/1μA10μA100μA10mA0.1μA/1μA10μA100μA10mAResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ

Accuracy

±0.3%rdg±2dgt

±1.0%rdg±5dgt(50Hz~500Hz)

Accuracy

±0.75%rdg±2dgt

±1.5%rdg±2dgt

±1.5%rdg±6dgt(50Hz~500Hz)

Accuracy±0.3%rdg±3dgt

±0.3%rdg±2dgt

±1%rdg±2dgt±3%rdg±4dgt

Input Impedance>100MΩ≒11MΩ≒10MΩ>100MΩ≒11MΩ≒10MΩVoltage Drop<0.05V / <0.25V<0.1V<0.6V<0.5V<0.05V / <0.25V<0.1V<0.6V<0.5VTest Current≦1.1mA≦110μA≦12.0μA≦1.2μA≦0.12μA≦0.12μA

SK-4033/SK-4035SK-4035

Open Circuit Voltage2.4V

1.2V

:::::

:::

SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyFuse

Dimensions WeightAccessories

4000 count LCD 10 times / secAuto / Manual RangingAC adapterF29 (3A/600V ) x 1, F30 (10A/600V ) x 1F31 (0.5A/250V) x 295(H) x 200(W) x 260(D) mm, 1,140g100-57 Test Leads (x 1 set), AC AdapterSpare Fuse F31 (0.5A / 250V) x 1

DCVoltage

ACVoltage

DCCurrent

ACCurrent

Resistance

Functions

SK-4033/4035

Waster

Suitable for theinspection automation

OutputTerminals

FrequencyDuty Cycle

Continuity Test

Diode Test

Capacitance

Cla

mp

Met

ers

Insu

latio

n Te

ster

s / E

arth

Test

erD

igit

al M

ult

imet

ers

An

alo

g M

ult

ites

ters

Au

tom

oti

ve T

este

rsO

ther

Tes

ters

Acc

esso

ries

33

Range400mV4V40V400V500V400mV4V40V400V500VRange400Ω4kΩ40kΩ400kΩ4MΩ40MΩOpen Circuit Voltage : ≦0.25V

400Ω (Buzzer Sound : 12Ω to 70Ω)

2VOpen Circuit Voltage : ≦2.9VAuto Power Off

Resolution100μV1mV10mV100mV1V100μV1mV10mV100mV1VResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ

Accuracy

±0.5%rdg±3dgt

±0.8%rdg±3dgt±1.0%rdg±8dgt (100mV~)

±0.8%rdg±3dgt

±1.2%rdg±3dgtAccuracy±1.0%rdg±5dgt

±1.0%rdg±3dgt

±2.0%rdg±3dgt

±5.0%rdg±3dgt

Input Impedance

≒5MΩ

≒5MΩ

1±0.6mA

DCVoltage

ACVoltage

Resistance

Functions

OPTIONAL ACCESSORY940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin

FEATURES

●Auto-SCAN Measurement. No need for selecting

DC/AC Voltages and Resistance ranges.●Only 11mm thick and 72g in Weight.●Easy-to-read largeLCD.●Equipped with carrying case.●Gold-plated Test Lead Pins.

SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyCE MarkDimensions WeightAccessories

::::::::

4000 count LCD 3 times / secAuto Ranging1.5V LR44 Batteries (x 2)CATⅡ500V and EMC112(H) x 56(W) x 11(D) mm Approx. 72g1.5V LR44 Batteries (Installed) (x 2)1005 Carrying Case

Auto Measurement for DC / AC Voltage & Resistance

AC/DC

V APOΩ

Digital Multimeters (Card-Type DMM)

Continuity Test

Diode Test

Range200mV2V20V200V600V2V20V200V600VRange200Ω2kΩ20kΩ200kΩ2MΩ20MΩOpen Circuit Voltage : ≦0.45V

200Ω (Buzzer Sound : Approx. 50Ω or less)

2VOpen Circuit Voltage : ≦1.7VDisplay Hold, Auto Power Off

Resolution100μV1mV10mV100mV1V1mV10mV100mV1VResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ

Accuracy±1.3%rdg±5dgt

±1.3%rdg±3dgt

±2.0%rdg±8dgt

Accuracy

±2.0%rdg±4dgt

±5.0%rdg±4dgt

±5.0%rdg±4dgt

Input Impedance≧100MΩ≒12MΩ

≒10MΩ

≒12MΩ

≒10MΩ

Test Current≦1mA≦0.3mA≦40μA≦4μA≦0.4μA≦0.04μA

≦0.7mA

DCVoltage

ACVoltage

Resistance

Functions

OPTIONAL ACCESSORY940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin

SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyCE MarkDimensions WeightAccessories

::::::::

2000 count LCD 3 times / secAuto Ranging3V CR2032 Battery (x 1)CATⅡ600V, CATⅢ 300V and EMC109(H) x 55(W) x 9(D) mm Approx. 60g3V CR2032 Battery (x 1)Notebook type Carrying Case

FEATURES●Compact & Light Weight.●Wide Measurement Ranges.●Gold-plated Test Lead Pins.● Large Rotary Switch.●Useful Functions.

Simple & Easy

AC/DC

V APODISPHOLDΩ

Advantages of SK-6500

Notebook typeCarrying CasePocketab le tes te r fo r easy to carry around.

UltraslimCard-type DMMObviously slim and light weight. Only 9mm thick and 60g weight.

Auto-SCAN Measurement

Continuity Test

Diode Test

DC VoltageExample : Battery

AC VoltageExample : Wall outlet

ResistanceExample : 5Ω resistor

KU-1199

Turn on the instrument with Rotary Switch. “SCAN” is displayed.Connect Black Test Prod to the - (earth) side of the circuit to be measured and Red Test Prod to the + (positive) side.The instrument automatically detects the items to be measured (DCV, ACV or Ω) and start the measurement. Read the test result on LCD.

1.

2.

3.

Clam

p Meters

Insulation Testers / Earth TesterD

igital M

ultim

etersA

nalo

g Mu

ltitestersA

uto

mo

tive Testers

Oth

er Testers

Accesso

ries

34

Analog Multitesters

KF-20

Tough-designed Holster with Test Lead Holder

ΩDC

AAC/DC

V

Range

0.3 / 3 / 12 / 30 / 120 / 300 / 1200V

12 / 30 / 120 / 300 / 1200V

60μ/ 3m / 30m / 300mA

5k / 500k / 5MΩ

1.5V (R20P / R14P / R6P)1.5V 250mA (Hi Range)1.5V 50mA (Low Range)

InternalResistance

20kΩ/V

10kΩ/V

Tolerance

±3% f.s.

±4% f.s.

±3% f.s.

±3% f.s. length

948 Alligator Clips793 Coil-Type Contact Pin

SPECIFICATIONSPower SupplyFuseDimensions WeightAccessories

:::::

1.5V R6P or AA Battery (x 1)F12 (0.3A / 250V) x 1136(H) x 90(W) x 30(D) mm 215gHolster100-51 Test Leads (x 1 set)1.5V R6P Battery (built-in & spare) x 1 eachSpare Fuse F12 (0.3A / 250V) x 1

OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips

948 Alligator Clips793 Coil-Type Contact Pin

SPECIFICATIONSPower SupplyFuseDimensions WeightAccessories

:::::

1.5V R6P or AA Battery (x 1)F15 (0.75A / 250V) x 1136(H) x 90(W) x 30(D) mm 215g100-64 Test Leads (x 1 set)1020 Carrying Case, 1.5V R6P Battery (x 1)Spare Fuse F15 (0.75A / 250V) x 1 (built-in)

DC 12A measurement

DCVoltage

ACVoltage

DCCurrent

Resistance

BatteryTest

BATT.TEST

Range

0.3 / 3 / 12 / 30 / 120 / 300 / 1200V

12 / 30 / 120 / 300 / 1200V

60μ / 3m / 30m / 600m / 12A

5k / 500k / 5MΩ(×1 / ×100 / ×1k)

Buzzer sounds less than approx. 30Ω

InternalResistance

20kΩ/V10kΩ/V

Tolerance

±3% f.s.

±4% f.s.

±3% f.s.

±3% f.s. length

KF-32FEATURES●DC 12A measurement.

AC/DC

V ΩDC

A

OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips

*Continuous measurement in 12A DC range is restricted up to 1 minute. More than 1 minute interval is necessary for the next measurement.

DC Voltage

AC Voltage

DC Current

Resistance

Continuity Tests

Advantages of KF-32

Easy-to-read large characterDC12A RangesBig current can be measured in DC 12A range.

Scale plate with mirrorThe mirror to help the correct reading avoiding the reading error.

Test Leads with gold plated pins

Advantages of SK-8301

Triaxial ELF Magnetic Field Meter

True RMS! High Performance!

APOMAXM I N

AVERAGE

FEATURES●Accurate Measurement by Triaxial Sensor.●True RMS.

SK-8301 TRIAXIAL ELF MAGNETIC FIELD METER

Range20.00μT200.0μT200.0mG2000mGMAX/MIN, Average, Display Hold, Auto Power Off

Resolution0.01μT0.1μT0.1mG1mG

Accuracy±2%rdg±5dgt (50/60Hz)±5%rdg±5dgt (40Hz to 1kHz)±2%rdg±5dgt (50/60Hz)±5%rdg±5dgt (40Hz to 1kHz)

Maximum. Input

200.0μT

2000mG

::::::::::

SPECIFICATIONSDisplayOperating PrincipleSampling RateRange SelectionRectificationPower SupplyCE MarkDimensions WeightAccessories

2000 count LCD, Maximum Reading 2000 Triaxial True RMS (X, Y, Z)2 times / secondAuto RangingTrue RMS1.5V R6P or AA Batteries (x 2)EMC test passed148(H) x 83(W) x 33(D) mm, 220g1015 Carrying Case1.5V R6P Batteries (x 2)

μTmeasurement

mGmeasurementFunctions

DISPHOLDμT mG

Electromagnetic comes from mixed directions if multiple sources are existing. Even in such field., SK-8301 can measure correct magnetic flux density by its triaxial (X, Y, Z) sensor.

X:Right and leftY:Back and forthZ:Up and Down

Y

X

Z

SK-8301

TRIAXIAL ELFMAGNETIC FIELD METER

Y

X

Z

REC DH

DISPLAYHOLD POWERMAX / MIN

AVG

In the field of multipleelectromagnetic sources

Accurate Measurement by Triaxial Sensor

True RMSDue to large distortion contained in electromagnetic wave, measurement result by average rectification meter should be incorrect. SK-8301 measures in True RMS and the measurement result is always accurate.

Cla

mp

Met

ers

Insu

latio

n Te

ster

s / E

arth

Test

erD

igit

al M

ult

imet

ers

An

alo

g M

ult

ites

ters

Au

tom

oti

ve T

este

rsO

ther

Tes

ters

Acc

esso

ries

35

Digital Sound Level Meter

For Sound Level Check of Living Environment

FEATURES●Select frequency weighting (A/C).●Select time weighting (FAST/SLOW).●Rubber Grip.●MAX/MIN measurement.●Display Hold.●Auto Power Off.

SPECIFICATIONSDisplayMeasuring RangeAccuracySampling RateTime WeightingPower Supply Dimensions WeightAccessories

:::::::::

11mm high 30dB to 125dB (A Weighting / C Weighting) ±5dB2 times/second125ms (FAST mode) or 1s (SLOW mode)9V 6F22 x 1193(H) x 67(W) x 44(D) mm 184gWind Screen, 9V 6F22 Battery x 1(Installed),

OPTIONAL ACCESSORIES1026 Carrying Case

Sound Level

120dB

110dB

100dB

90dB

80dB

70dB

60dB

50dB

40dB

30dB

20dB

Sound Example

Airplane take off at 300m

Car horn at 2m

Chain saw

Noisy factory

Subway inside (open-window), Piano

Vacuum cleaner, Noisy office

Normal conversation, TV sound

Quiet office

Library

Whispering voice

Leaves rustling

KG-70

APOLUX MAXM I N

DISPHOLD

Sound levels in everyday lifeNoisy sound such as from factory, airplane, or automobile sometimes disturbs our comfortable life.Generally, quiet sound level in everyday life is less than 45dB, Comfortable sound level will be around 40dB to 60dB.

APOdBSOUND MAX

M I NDISPHOLD

Verypainful

Verynoisy

Loud

Moderate

Quiet

Measurement Procedures①Press POWER Key and turn the power on.②Remove the sensor cap.③Hold out the sensor to the object to be measured.④Read the measurement value on LCD.

Digital Light Meter

For Illuminance Testing for Indoor Facilities

FEATURES● Lux and Fc (foot-candle) are selectable.●Backlight LCD.●Rubber Grip.●MAX/MIN measurement.●Display Hold.●Auto Power Off.

SPECIFICATIONSDisplaySensorMeasuring RangeSampling RateRange SelectionPower Supply Dimensions WeightAccessories

:::::::::

11mm high Silicon photodiode and filter0 to 99990Lux, 0 to 9999Fc 2.5 times/secondAuto Ranging9V 6F22 x 1192(H) x 67(W) x 44(D) mm 198g9V 6F22 Battery x 1(Installed),

OPTIONAL ACCESSORIES1026 Carrying Case

KG-75

LCD shows ×10 sign whenmeasurement value exceeds9999Lux. Example : 56180Lux

Measurement units1Lux : Equal to one lumen per square meter.1Fc : Equal to one lumen per square feet.1Lux ≒ 0.09290Fc  1Fc ≒ 10.764Lux

"x10" lights up

Accuracy

0 to 300Lux:±6%±3dgt301 to 4000Lux:±6%4001 to 99990Lux:±10%

Backlight, MAX / MIN, Display Hold, Auto Power Off

Resolution0.01Lux0.1Lux1Lux10Lux

Range0.00 to 19.99Lux20.00 to 199.9Lux200 to 9999Lux1000 x 10 to 9999 x 10LuxFunctions

Advantages of SK-8530

Backlight LCDEasy reading even in the dark places.

MAX/MIN measurementDisplay should change as following by pressing MAX/MIN Key.

Display HoldFreeze the readings by pressing HOLD Key.

Auto Power OffPower turns off automatically after approx. 5 minutes of last operation.

Rubber GripSide rubber assures good grip neatly fit in your hand.

Clam

p Meters

Insulation Testers / Earth TesterD

igital M

ultim

etersA

nalo

g Mu

ltitestersA

uto

mo

tive Testers

Oth

er Testers

Accesso

ries

100-40Lead Wires

(Red x 2, Black x 1)

795Test Pins

(Red x 2, Black x 1)

942BAlligator Clip

(Black x 1)

100-72 Oscilloscope Test Lead Set

Narrow test pins that can insert wire harness.Included 2 sets of red test leads / test pins allows 2-channels measurement. Use black alligator clip for grounding.

Changeable

100-74 Ripple Voltage Test Lead

Major test lead for our products. Gold-plated pins assures long-lastingcontact.

Gold platedpins

100-57 Test Leads

Applicable ModelsSK-7682 / 7718 / 7719 / 7720 / 7722 / 7708

7615 / 7625 / 6161 / 6163 / 6150 / 40334035 / 6166

36

Test Leads

100-41 Test Lead Kit

Connect Test Plugs and Test Pipes of 100-40 Lead Wire, and connect 3 kinds of Test Pin or 2 kinds of Test Hook.

Test Plug of100-40 Lead Wires

767 / 769 / 792 Test Pin790 / 791 Test Hook766 Test Pipes

Applicable ModelsSK-2500 / 7682 / 7718 / 7719 / 7720 / 7722 / 7708 / 7615 / 7625 / 6161 / 6163 / 6150 / 4033

4035 / 6166KU-2600 / 2602 KF-32 / 20 KT-2021

Newly-developed test lead for our mini-clamp meter series.+ / - integrated connector that can hardly pulled out during measurement.

Test Leads

Applicable ModelsSK-7660 / 7661 / 7602 / 7603 / 7820 / 7825

Connector

Test PipesMax. Voltage : 1000VMax. Current : 10A

Alligator ClipsMax. Voltage : 1000VMax. Current : 20AJaw Opening : 20mm

Test Pin

100-40Lead WiresWire Length : 1.6mMax. Voltage : 1000VMax. Current : 10A

1002Carrying case

Straight Test PinTest HookL Type Test Pin

15mm

100-40Lead Wire

766RRed Test Pipe

942BBlack

Alligator Clips

792RRed Straight

Test Pin

Test Lead SetLead WiresRed Test PipeRed Straight Test PinBlack Alligator Clip

Models100-40766R792R942B

Applicable ModelsSame models 100-41

Test Lead SetCombination of useful components from 100-41.

*Red and black parts are contained except for 790 and 791.

Test Lead KitLead WiresTest PipesTest PinsL Type Test PinsTest Hook for Dark CurrentTest Hook for Dark CurrentStraight Test PinsAlligator Clips

Models100-40766767769790791792942

ModelsLength of PinInside DiameterTip DiameterMax. VoltageMax. Current

76719mm-

φ2mm1000V10A

79225mm-

φ0.5mm100V1A

76915mm-

φ0.9mm1000V1A

79068mmφ10mmφ0.9mm100V1A

79174mmφ16mmφ0.9mm100V1A

Applicable ModelsSK-2500

Applicable ModelsSK-2500

Can view the Ripple Voltage waveform of the alternator by removing DC elements from the measuring voltage.

Battery

alternator

B Terminal100-74 Test Lead (Red)

100-57 Test Lead (Black)(Supplied with SK-2500)

HANDY OSCILLOSCOPE

Cla

mp

Met

ers

Insu

latio

n Te

ster

s / E

arth

Test

erD

igit

al M

ult

imet

ers

An

alo

g M

ult

ites

ters

Au

tom

oti

ve T

este

rsO

ther

Tes

ters

Acc

esso

ries

37

Temperature Probe Clamp Adapter

Applied for the testers that have temperature measurement function.

818-02 Temperature Probe

Measurement-50℃ to 100℃

Applicable ModelsSK-2500 / 7720 / 7722KU-2602KT-2021

AC / DC Clamp Adapter660 can measure up to 400A AC / DC by using in combination with Digital Multimeters that can measure 400mV AC / DC.

MeasurementAC 0 to 400ADC 0 to 400A

Applicable ModelsKU-2600 / 2602SK-6161 / 6163 / 6150 / 4033 4035 / 6166KT-2021

Battery Cable

Replaceab le bat tery cab le by onescrewdriver.

Applicable ModelsSK-8550

Alligator Clips

Applicable ModelsSK-7660 / 7661 / 7682 / 7718 / 7719 / 7720 / 7722 / 7708

7602 / 7603 / 7615 / 7625 / 7820 / 7825 / 3500* / 3502*6161 / 6163 / 6150 / 6597 / 6592 / 4033 / 4035 / 65556500 / 6166

KU-2600 / 2602 / 1199 KF-32 / 20

*Only red clip is available for SK-3500 / 3502.

Applicable ModelsSK-7660 / 7661 / 7718 / 7719 / 7720 / 7722 / 7708 / 7602

7603 / 7615 / 7625 / 7820 / 7825 / 3500* / 3502* / 61616163 / 6150 / 6597 / 6592 / 4033 / 4035 / 6555 / 6500

KU-2600 / 2602 / 1199 KF-32 / 20*Only red clip is available for SK-3500 / 3502.

Alligator Clips

CE Mark : CAT Ⅱ 300V class 2 and EMC

*Can not use for SK-8530 / SK-8535.

819 Temperature Probe

Measurement-50℃ to 700℃

Applicable ModelsSK-2500 / 7720 / 7722KU-2602KT-2021

Test Pins

Clips

Coil-Type Contact Pin

Extra fine test pin. It takes care not to scratch the object by spring structure.

Applicable ModelsSK-7660 / 7661 / 7682 / 7718 / 7719 / 7720

7722 / 7708 / 7602 / 7603 / 7615 / 76257820 / 7825 / 6161 / 6163 / 6150 / 65976592 / 4033 / 4035 / 6555 / 6500 / 6166

KU-2600 / 2602 / 1199 KF-32 / 20 KT-2021

φ0.4mm

This test pin is suitable for narrow point measurement. That can measure with inserting the pin to the backside of insulation coupler of the car.

Test Pin

Applicable ModelsSK-2500 / 7661 / 7682 / 7718 / 7720 / 7722

6166 / 6597 / 6594 KT-2021

φ0.4mm

Max. Current : 1A Max. Voltage : 50V

Straight Test Pin

φ0.5mm

Extra fine and elastic test pin only 0.5mm diameter, that is very suitable for narrow point measurement. Insulation coated bottom to prevent incorrect measurement.

Applicable ModelsSK-6592 / 6597 / 100-41

*Only red pin is available for SK-6592 / 6597 / 6598.

Max. Current : 1A Max. Voltage : 50V

Extra fine test pin only 0.5mm diameter. It is very suitable for narrow point measurement. Use it with connecting to 100-40 test plug.※Difference from 792 straight test pin : 795 can connect to 100-40 directly without  766 test pipes.

Test Pin

Applicable ModelsSK-8402 / 100-40 / 100-72

Max. Current : 1A Max. Voltage : 50V

φ0.5mm

817-03 / 17 / 19 / 25 Temperature Probe [TYPE K (CA)]

MODEL Tip Form Dimensions

φ14

98

φ1.6 SUS316

150

φ3.2 SUS316

150

φ14

98

φ3.2 SUS316

150

φ14

98

500 125

φ15φ5.0817-03

817-17

817-19

817-25

2~3 5

Unit : mm

Liquid Temp.

Internal Temp.

Internal Temp.

Air Temp.

Measurement817-03 : -50℃ to 1150℃817-17 : -50℃ to 600℃

Applicable ModelsSK-7720 / 7722KU-2602 / KT-2021

817-19 : -50℃ to 750℃817-25 : 0 to 200℃

800 Battery Cable

Printer Paper

Optional printer paper for SK-8530 / 8535 / 8550 Battery Checkers.

Applicable ModelsSK-8530 / 8535 / 8550

QuantityWidthLength

10 rolls / set Approx. 57mmApprox. 5.8m

851 Printer Paper

Mark Descriptions

38

CapacitanceCapacity of electronic capacitor (electrostatic capacity) is measurable in F (farad) unit.

Diode Test Diode test is possible measuring its forward and reverse side.

TemperatureTemperature is measurable using the temperature probes.

AC CurrentAC Current measurement is possible.

AC

A

DC CurrentDC Current measurement is possible.

DC

A

FrequencyFrequency measurement is possible.Hz

Decibel (low-frequency output)Low frequency output like audio amplifier is measurable in dB (decibel) unit.

dB

Pulse WidthWaveform pulse width for logic or switching controls are measurable in ms (milli-second) unit.

PULSEWIDTH

Dwell AngleElectricity time for automobile engine is measurable converting into an angle.

DWELLANGLE

Revolutions Per MinuteRPM of automobile engine is measurable.

RPM

AC VoltageAC Voltage measurement is possible.

AC

V

Duty CycleThe duty cycle of repeating waveform is measurable and indicated in a percentage basis(%).

DUTY

%DC VoltageDC Voltage measurement is possible.

DC

V

ResistanceResistance measurement is possible.Ω

Continuity TestThe buzzer sounds when the measuring object is electrically conducting.

Low ResistanceLow Resistance measurement is possible.Ω

LOW

Sound LevelNoise level measurement is possible.

IlluminanceIlluminance measurement is possible.

TRUERMS

True RMS (True root-mean-square value)True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.

APOAuto Power OffPower is automatically turned off when a certain period of time has elapsed after the power on. Some models are enabled to cancel this function.

APSAuto Power SaveDisplay is automatically turned off and into power save condition when a certain period of time has elapsed after the power on. Some models are enabled to cancel this function.

Simple WaterResistant

Simple Water ResistantWater-Resistant case is used to protect the tester from water damage.

DATAMEMO

Data MemoryMeasurement data can be saved in internal memory.

AUTOZERO

Power-On InitializeAutomatic Zero-Adjustment function to adjust LCD indications into 0±1 digit when powered on.

DropProof

Drop ProofAnti-shock structure enables to protect the tester from the strong shock by the 1-meter-dropping-off.

OUTPUT

Output TerminalAn output terminal connectable to the Oscilloscopes or Recorder is available.

DustProof

Fireproof

Dust ProofDust-proof case is used to protect the tester from dust damage.

LPFLow Pass FilterFrequency signals higher than the specified cutting-off frequency are intercepted.

Backlight LCDUseful for easy reading even in dark areas.

DISPHOLD

Display HoldEnables to hold the indicating values on LCD. Useful to note down the measurement values.

MAXM I N

MAX / MINThe minimum and maximum of the measurement values are measurable and indicates on LCD.

AVERAGE

AverageThe average of the measurements value for a certain period of time is measurable.

PEAKHOLD

Peak HoldThe Peak current value in a certain period of time is measurable and indicates on LCD.

DIFFDifferenceA certain measurement value is stored and converted into zero. The difference between measuring value and stored value is indicated with proceeding measurements.

RNGHOLD

Range HoldEnables to hold the ranges when the Current or Voltage values are unstable and difficult to read.

Measurement Items

Measurement Functions

Battery TestBattery voltage and its condition are tested applying a certain current to the tester.

BATT.TEST

Fireproof CaseThe fireproof case protects the instrument inside from fire.

Magnetic FieldMagnetic Field measurement is possible.

μT mG

BARGRAPH

BargraphBar Graph is available on LCD. Zoom-up function is available for some models.

COMPComparator (Comparing function)Buzzer sounds when the input value is beyond the specified high and low limits.

PENLIGHT

PenlightBrightly illuminate test points with LED light. Useful for testing in dark place.

Error inputwarning

Error input warning Safety function to prevent incorrect test lead connection.

LUX

dBSOUND

www.kaise.com

DISTRIBUTOR

70-0201-0000-7 1703

422 Hayashinogo, Ueda City, Nagano Pref., 386-0156 Japan

Telephone : +81-268-35-1601 Fax : +81-268-35-1603

E-mail : [email protected]