P1 vol4 目次 - kaise.com
Transcript of P1 vol4 目次 - kaise.com
Battery Checkers
Oscilloscope
Handy mΩ Tester
Low Current DC Clamp Meter
AC / DC Digital Clamp Meters
Automotive Digital Multimeters
Digital Multimeters (Probe Tester)
Digital Insulation Tester
Digital Tachometer
O2 Sensor Checker
AC / DC Digital Clamp Meters
AC Digital Clamp Meters
AC Leakage Clamp Meters
Analog Insulation Testers
Digital Insulation Testers
Handy-Type
Probe Tester
Bench-Top DMM
All-in-one DMM
Card-Type DMM
Analog Multitesters
Triaxial ELF Magnetic Field Meter
Digital Sound Level Meter
Digital Light Meter
Other Testers
Accessories
Mark Descriptions
Contents
Digital Multimeters
Analog Multitesters
Clamp Meters
Insulation Testers
Automotive Testers 3
4
5
7
8
9
9
10
11
12
13
13
14
14
15
15
19
19
19
20
20
20
20
21
21
22
22
22
23
23
23
24
24
24
25
25
29
29
30
30
30
31
31
32
32
32
33
33
34
34
34
35
35
36
37
38
SK-8550
SK-8535
SK-2500
SK-3800
SK-7830
SK-7661
SK-7682
SK-7718
SK-7720 / 7722
KT-2021
SK-6166
SK-6597
SK-6592
SK-3502
SK-8401
SK-8402
SK-7660
SK-7661
SK-7682
SK-7718
SK-7719
SK-7720
SK-7722
SK-7708
SK-7601
SK-7602
SK-7603
SK-7615
SK-7625
SK-7820
SK-7825
SK-3002
SK-3003
SK-3005
SK-3500
SK-3502
KU-2600
KU-2602
SK-6161
SK-6163
SK-6150
SK-6597
SK-6592
SK-4033
SK-4035
SK-6555
KU-1199
SK-6500
KF-32
KF-20
SK-8301
KG-70
KG-75
100-41 / 100-62 / 100-63100-57 / 100-72 / 100-74
792 / 793 / 795 / 944 / 948 / 940818-02 / 819 / 817-03 / 817-17817-19 / 817-25 / 660 / 800 / 851
2
Note the following WARNINGS and CAUTIONS when using Electric / Electronic Measuring Instruments.
Caution Symbol on the instrument indicates that the user should
read carefully the operating instructions in the manual.
High Voltage Warning Symbol on the instrument indicates that
a potential of 1000V or more high voltage may be present on the
Terminals. The user should use extreme care about safety practices.
Maximum Allowable Ground Voltage Symbol on the instrument
indicates that the maximum voltage between INPUT Terminals
and Earth Ground is 500V in this case. The user must not apply any
voltage that will exceed the maximum voltage.
Safety Symbols1
The ordinary multimeters, analog or digital, are provided with maximum range of
500V to 1000V AC and DC. But, most of them are designed to measure Low Power
Circuits such as TVs, Radios and home electrical apparatus.
Therefore, to measure High Power Circuits or High Power Line more than 220V, such
as Power Supplies for Factory Equipments and Facilities, etc., do NOT use any
ordinary multimeters. Use the instruments especially designed for High Power Line.
High Power Line sometimes includes Surge Voltage more than 10 times of the rated
voltage. So, the Surge Voltage will cause electric shock accidents when measuring
with the ordinary multimeters. Even if the circuit to be measured is of Low Power, if
the voltage is greater than 220V, use the instruments with great care observing
warnings and cautions written in the instruction manuals concerned.
Warnings for High Power Line andHigh Voltage Measurements
2
Traceability ChartTraceability to prove the compliance with national and international standards is an essential factor for measuring instruments used as test instruments associated with quality
assurance. Products of Kaise are calibrated by reference samples which is periodically checked for its compliance with national standards. A calibration certificate and test data
report are available on your request.
Comparative Standards
AC/DC Voltage Resistance Frequency Capacitance Temperature Humidity AC/DC Current
LCR Meter Digital thermohygrometer Current Shunt
National Standards
Calibration Standards
Applied Standards
Calibrated Parameters
National Institute of AdvancedIndustrial Science and Technology
AISTNational Institute of Informationand Communications Technology
NICTNational Institute of Standardsand Technology
NISTJapan Electric Meters InspectionCorporation
JEMIC
High-Accuracy Digital Multimeter
CE Mark
CE marking is a safety mark which can be attached only on a product meeting the safety requirements of the Directive of Council of the European Union (EC
Directive).
A product attached with the CE mark is designed so as to meet the requirements of the "Low Voltage Directive" and "EMC Directive" of the EC Directive. Low
Voltage Directive: This Directive covers products of power supply voltage of 50V-1000V(AC) and 75V-1500V(DC), and it defines electric safety requirements
against shocks, burns, etc. The applicable standard is EN61010 corresponding to IEC1010 give on the left. EMC Directive: This Directive stipulates conditions
so as not to give out strong electromagnetic waves from equipment to the outer environment and to protect equipment from the effect of electromagnetic waves
from the outside.
Higher-numbered categories correspond to electrical environments with greater momentary energy, so a measurement product designed for CAT Ⅲ environments can endure
greater momentary energy than one designed for CATⅡ. Using a measurement product in an environment designated with a higher-numbered category than that for which the
product is rated rated could result in a severe accident, and must be carefully avoided.
Never use a CATⅡmeasuring product in CATⅢ, or Ⅳ environments.
The measurement categories comply with the Overvoltage Categories of the IEC 60664 Standards.
For Safety
The International Safety Standard IEC61010To ensure safe operation of measurement products, IEC 61010 establishes safety
standards for various electrical environments, categorized as CATⅡto CAT Ⅳ, and
called measurement categories. These are defined as follows.
CAT.ⅡPrimary electrical circuits in equipment connected to an AC electrical outlet
by a power cord (portable tools, household appliances, etc)
CAT.ⅢPrimary electrical circuits of heavy equipment (fixed installations) connected directly
to the distribution panel, and feeders from the distribution panel to outlets.
CAT.ⅣThe circuit from the service drop to the service entrance, and to the power
meter and primary over current protection device (distribution panel).
Distribution board
CAT.Ⅳ
CAT.Ⅲ
CAT.Ⅱ
Indoor wiring
Power receptaclePower receptacle
Service entrance
Watthour meter
Service wire
Kaise conforms to IEC 61010-031 (safety standard for hand-held probes) by using test lead caps.Required standards : Exposed metal part must be 4mm or shorter for
CAT IV and III environments to prevent short-circuits from occurring.
Insulation Capfor Test Lead
Cap attachedNo Cap attached
For CAT Ⅱenvironment For CAT Ⅲ and Ⅳ environments
Measuring Instruments in R&D, Production, Inspection and Service Department
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
3
Battery Checkers
FEATURES●Can record frequently tested batteries as favorites list.●Can count and record the number of testing.●One-touch printing by Dierct-Print Key available on the instrument.●Detachable battery cable for easy replacement.● Editable header / footer function that can print favorite names or pictures (shop name, etc.) on the printer paper.
SPECIFICATIONSDisplayLanguage (display & print)
PrinterPower SupplyTestable Battery
Battery Standard
Measurement RangeCE MarkDimensions WeightAccessories
LCD (dot matrix display :128×64 dots) Japanese, English (Default setting : English)Bult-in Printerfrom Test Battery or USB connection12V Battery※24V battery : engine startability test and charging system test are available. JIS, EN / DIN, SAE / BCI※CCA input or Industrial battery selectable100 to 1400CCA, Industrial :1.0mΩ to 50.0mΩEN61326-1248(H) x 96(W) x 55(D) mm Approx. 670g800 Battery cable (attached), 934 USB Cable, Printer Paper (x 2, for testing sample, 1 roll is attached in the unit), 1032 Carrying Case
:::::
:
:::::
12VBattery Test
OPTIONAL ACCESSORIES851 Printer Paper800 Battery cable
12V & 24V Start Performance, Charging System Test
How to Test①Connect battery clips to +/- terminals.②Set the testing condition in SK-8550.③Start a Battery Test.④Start a Battery System Test.
Advantages of SK-8550
Header / Footer FunctionCan edit and print the favorite names or pictures (shop
name, etc.) on printer paper as header and footer, by
downloading the user application from Kaise website.
Favorite FunctionCan record up to 50 frequently tested battery codes as
favorite list. You can find the battery to be tested easily
by pressing “FAVORITES” Key. Record name is editable.
You can print out the testing result easi ly by just
pressing direct-print key available on the instrument.
Direct-Print Key
Battery cable tends to be damaged by everyday battery
testing.
For SK-8550, you can replace the battery cable by only
one screwdriver.
Detachable Battery Cable★FAVORITES ▲▼01/20-72(AC Delco)02/SL-6C(BOSCH)03/572-20(ATLAS)04/1050S(OPTIMA)
Can Record “CCA /mΩ” in Favorite listYou can record “CCA / mΩ” values in favorite list. This
can help easy testing without inputting these values for
every test.
(CCA values are edited into battery codes in the following
example.)
Number of Testing CounterCan count and record the number of testing. This
function helps to check your maintenance record.
View Test Count
Battery Test 52System Test 37 Press Hold : Reset
800 Battery Cable (for replacement)
New and Improved Battery Checker with Advanced Functions
SK-8550
Test Result : Good
Date and Time 2017/03/15 15:00(Aging Test Mode)
Battery Test Report
ABC MechanicalTel XXX-XXX-XXXFax XXX-XXX-XXXE-Mail [email protected]
Periodical test isrecommended.
SOC (State of Charge) : 100%
SOH (State of Health) : 100%
Battery TypeModel No.Measured CCABattery VoltageTemperatureTesting Mode
JISQ-85
615CCA12.780V
24℃
Charge controller / Idle Reduction
Header
Terminal
TerminalBATTERY
CHECKER
MAX 32V
FAVORITES
SK-8550
Clam
p Meters
Insulation Testers / Earth TesterD
igital M
ultim
etersA
nalo
g Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
4
Battery Checkers
FEATURES● For the automotive batteries with EN/DIN, SAE/BCI, and JIS standards.●Applicable to the vehicles with Charge Controller or Idle Reduction systems.●Auxiliary battery test for TOYOTA-Hybrids.●Attention (Caution) result added.●Double Dierential Pulse Test Method for more accurate testing.●Unused Battery Test Mode.●Carrying Case for Protection.●On-Site Printing with Built-in Printer.●Easy Database Upgrade through KAISE Website.
Advantages of SK-8535
Double Differential Pulse Test Method formore accurate testing
For the automotive batteries withEN/DIN SAE/BCI, and JIS standardsWhat tests available?①Battery Test・Battery Charging Level (SOC) ※SOC:State of Charge・Battery Condition (SOH) ※SOH:State of Health②Battery System Test・Engine Start Performance (Starting ability of the battery)・Charging System (Generating condition of alternator)
5-grade JudgementLED shows the test result by following 5-grade.“Attention” is useful to let the customer know thenecessity of battery replacement to prevent theunexpected battery-down.
SPECIFICATIONSDisplayLanguage (display & print)
PrinterPower SupplyTestable Battery
Battery Standard
Measurement RangeCE MarkDimensions WeightAccessories
LCD (dot matrix display :128×64 dots) Japanese, English, Chinese (Default setting : Japanese)Bult-in Printerfrom Test Battery or USB connection12V Battery※24V battery : engine startability test and charging system test are available. JIS, EN / DIN, SAE / BCI※CCA input or Industrial battery selectable100 to 1400CCA, Industrial :1.0mΩ to 50.0mΩEN61326-1248(H) x 96(W) x 50(D) mm Approx. 550g934 USB Cable, Printer Paper (x 2, for testing sample, 1 roll is attached in the unit), 1035 Carrying Case
:::::
:
:::::
Quick and Accurate Car Battery & System Test with Single Hand-Held Equipment
SK-853512VBattery Test
OPTIONAL ACCESSORIES851 Printer Paper
12V & 24V Start Performance, Charging System Test
Battery Test
System Test
Model No.WidthLength
: 851: Approx. 57mm: Approx. 5.8m
Please Purchase this printer paper for replacement.
Printer Paper ※Option (10 rolls per set)
Built-in PrinterQuick-and-easy printing of the test results from built-in printe.
Applicable to the vehicles with ChargeController or Idle Reduction systemsAccurate testing with the specific test program and standard numbers which are designed for their testing purpose.
Unused Battery Test ModeSpecial mode for testing unused (new) batteries which are stocked in car dealers or garages. This is effective to keep them in good condition preventing unexpected battery aging during storage.
Test Result Saving & PC ConnectionUp to 99 data can be saved to the internal memory.Onforwarding to PC in text data is possible.
Auxiliary battery test for TOYOTA-HybridsApplicable to auxiliary batteries models S34B20 / S46B24 S55D23 / S65D26 which are used for TOYOTA-Hybrid vehicles such as Prius, or Prius C.
Industrial Battery Testing
Carrying Case for ProtectionEnhanced portabi l i ty and dust protection for the instrument.
High-Intensity Polycarbonate Body
Easy Database Upgrade throughKAISE Website※PC and internet connection are required.
Display & Print Language SelectableEnglish / Chinese / Japanese are available.
Built-in PrinterCan print the test results easily and quickly. Language selectable from English / Chinese / Japanese.
Test Result : Good
Date and Time 2016/03/15 15:00(Aging Test Mode)
Battery Test Report
Periodical test isrecommended.
SOC (State of Charge) : 100%
SOH (State of Health) : 100%
Battery TypeModel No.Measured CCABattery VoltageTemperatureTesting Mode
JISQ-85
615CCA12.780V
24℃
Charge controller / Idle Reduction
Battery test result
Testing date and time
Battery charging level (SOC)
Battery aging level(SOH)
Comment fortest result
Battery test mode
Condition oftested battery
System Test ReportDate and Time 2016/03/15 15:00(12V System)
Test Result : Good
Test Result : Good
Periodical test isrecommended.
START PERFORMANCE TEST
CHARGING SYSTEM TEST
CrankingStart Performance
8.619V100%
Charging VoltageRipple Voltage
14.523V0.110V
Testing date and time
Engine start performancetest result
Charging system test result
12V / 24V System
Comment for test result
Battery conditions atengine starting
Battery conditions
CHARGE BADGOOD
Good
Good/Charge
Attention
Charge/Retest
Replace
light
lightlight
flash
light
light
LED lights up or flashby test results
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
5
Oscilloscope
SPECIFICATIONSDisplayFrequency bandwidthMax. Sampling RateNumber of ChannelsAcquisition MemoryOscilloscope FunctionInternal Power Supply
External Power SupplyCE MarkDimensions WeightAccessories
Dot matrix LCD (240×128 dots), Display Size : 53mm(H)× 92mm(W)DC to 200kHz2MS / sec. 2 channels4096 pointsGraphic waveform display for voltage measurement1.5V LR6 or R6P batteries 4 pcs.(NiMH rechargeable battery usable)USB mini-B connector (DC5V)EN61010-1 CAT II 300V class 2, EN61326-1162mm(H)×167mm(W)×35mm(D)570g (excluding batteries)Holster (attached to the main unit), 100-57 Test Leads,903 AC/DC Adapter (USB 5V output), 934 USB cable, 1035 Carrying Case, 1.5V R6P Batteries 4 pcs
:::::::
:::::
2ch Hand-held Oscilloscope Especially for Car Mechanics
SK-2500
Advantages of SK-2500
Car Maintenance List - The Auto SetFunction for Car Sensors and SignalsThe most complicated thing to get the observable waveform with oscilloscope is the settings of voltage axis, time axis, and trigger.SK-2500 makes it easier by providing “Car Maintenance List”. Just choosing the sensor or signal to be measured, the instrument automatically adjusts the waveform and shows it on the screen.
Auto Axes AdjustmentAuto Adjustment for voltage and time axes.
Backlight LCDEasy reading even in dark environment.
Data Logger Function andData Processing on PCYou can record the measuring data with Data Logger function and can send it to PC for using in spreadsheet software like making graphs. SK-2500 can store up to 99 CSV and PNG data.
Screen Capturing Saved as Image DataScreen capturing saved as PNG format is available just pressing CAPTURE Key. Captured data can be recalled from the menu list to view on the screen or to move to the PC.You can see the colored image data on PC screen.
AC/DC Adapter PoweringUSB 5V output AC/DC adapter for cont inuous measurement. ※standard accessory
2ch Waveform DisplayTemperature Measurement(with optional temperature probe)
Digital Multimeter Functionin DMM ModeAC/DC Voltages, Resistance, Continuity, Frequency, Pulse Width, Duty Cycle, and Temperature measurements.
Help Function to SupportYour MeasurementPress HELP Key when you have questions in the operation. Help lists with useful hints or tips are displayed on the screen.
Rubber Holster for Shock Protectionand Improved RuggednessStandard oscilloscopes tend to be slippery due to its plastic chassis, and careful handling is required.SK-2500 added rugged so lut ion for hand-he ld oscilloscope with slip-proof rubber holster. This also offers stable placing even in the engine compartment.
Easy-to-Use Hand-Held OscilloscopeWithout Special AccessoriesSK-2500 can use as your daily tool, with oscilloscope, digital multimeter, and data logger in one single hand-held unit. Test probes and accessories are common with our other test & measurement products for enhanced usability.Usable : 100-41 Test Lead Kit, 100-62 Test Lead Set
Large-Sized Luminous Key Switches with Simple OperationFeeling difficulties in complicated key operation for using oscilloscope? Key switches of SK-2500 offers intuitive operation with illumination function, pictorial indications, and guide icons on the screen.
V
DISPHOLD
DUTY
%HzΩ
Graph mode
DMM modeAC/DC
V APOPULSEWIDTH
DATAMEMO
OPTIONAL ACCESSORIES660 AC/DC Clamp Adapter100-57R Red Test Lead100-72 Oscilloscope Test Lead Set100-74 Ripple Voltage Test Lead100-41 Test Lead Kit100-62 Test Lead Set653 RPM Sensor (for Direct Ignition)
650 RPM Sensor (for High Tension Cord)940 Alligator Clips793 Coil-Type Contact Pin944 Test Pin946 Battery Clip818-02 Temperature Probe819 Temperature Probe Other
Resistance
Voltage
DC Voltage Range200.0mV2.000V20.00V200.0V1000V
Resolution100μV
1mV10mV
100mV1V
Max. Input
1000V DC
Accuracy
±1.0%rdg±8dgt
±1.0%rdg±5dgt
V / Div200mV / 2V / 20V
500mV / 5V / 50V / 200V1V / 10V / 100V / 500V
Max. Input
1000Vp-p
Accuracy±4dot±2dot±1dot
DMM mode
Graph mode
Range2.000kΩ20.00kΩ
Resolution1Ω10Ω
Open Circuit Voltage
≦3.3V
Accuracy
±1.0%rdg±8dgt
Continuity Test, Frequency, Pulse Width, Temperature
Range
2.000V
20.00V
200.0V
600V
Accuracy±2.0%rdg±8dgt(45Hz~1kHz)±2.5%rdg±8dgt(1kHz~10kHz)±4.0%rdg±8dgt(10kHz~20kHz)±6.0%rdg±8dgt(20kHz~30kHz)±2.0%rdg±8dgt(45Hz~1kHz)±2.5%rdg±8dgt(1kHz~10kHz)±4.0%rdg±8dgt(10kHz~20kHz)±2.0%rdg±5dgt(45Hz~1kHz)±2.5%rdg±5dgt(1kHz~10kHz)
Max. Input
600V AC(rms)
Resolution
1mV
10mV
100mV
1V
AC Voltage(AC V rms)
※Crest factor 1.5 or less
Clam
p Meters
Insulation Testers / Earth TesterD
igital M
ultim
etersA
nalo
g Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
Oscilloscope
6
※See maintenance manual when making the measurement.
Waveform observation of cam and crank sensors in graph mode
Graph mode
DMM mode
Measurement Example
①Insert the Input Plugs of Test Lead to Input Terminals. Turn on the instrument.②Contact the Test Pins to the terminal to be
measured. The below picture is getting the signal input from wire harness connector using 100-41 Test Lead Kit.
Optional Accessories
※Optional 660 AC/DC Clamp Adapter is required.
2ch test for battery voltage and alternator current
①Insert test lead plug to CH1 input terminal, and insert clamp adaptor plug to CH2 input terminal.②Turn on the instrument (SK-2500).※F o r D M M m o d e , e n t e r D C v o l t a g e
measurement mode by pressing Test Mode key.③Contact test pins to the battery terminals.
Red to plus, black to minus.※940 alligator clip is used in the picture below.
④Select 40A range with the clamp adapter.⑤Clamp-on the B-terminal of the alternator.
⑥For graph mode, adjust voltage / time axes. Set trigger hold at 10V to stop the waveform as voltage drop at engine cranking. (set trigger slope as falling edge trigger.)⑦Start the engine.⑧Move and adjust the waveform to be more
visible.⑨Check the result on the LCD.
③Choose the item from Car Maintenance List. Auto set works for voltage / time axes, trigger, and waveform position to display camshaft position sensor waveform in CH1.
④Adjust voltage axis and waveform position to make space for CH2 waveform.⑤Press CH2 Key. Crankshaft position sensor
waveform is displayed on the screen. Adjust the voltage axis to be the same as CH1 and adjust the waveform position.
Battery voltage measurement in DMM mode
①Insert the Input Plugs of Test Lead to Input Terminals. Turn on the instrument.②Press TEST MODE Key to go to DC Voltage
measurement in DMM mode.③Contact the test pins to battery terminals (red
pin to plus terminal, and black pin to minus terminal).
④Read the measurement result on the screen.⑤Start the engine to let the alternator power
generated. Check the measurement value on the LCD that should be increasing. Measuring this voltage is effective to check the generating condition of the alternator.※For charge control vehicles, alternator might
not generate the power.
100-72Oscilloscope Test Lead SetNarrow test pins that can insert wire harness.Included 2 sets of red test leads / test pins allows 2-channels measurement. Use black alligator clip for grounding.
100-74Ripple Voltage Test LeadCan view the Ripple Voltage waveform of the alternator by removing DC elements from the measuring voltage.
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
7
Handy mΩ Tester
Low resistance measurement for the motors. Ideal for the maintenance of Hybrid and Electric vehicles.
SK-3800
DISPHOLDCOMP
ΩLOW
SimpleDust Proof
SimpleWater Resistant
FEATURES●Autonotive mΩ Tester focusing on the testing of Hybrid and Electric vehicles.●Easy-to -use handheld unit useful for automotive mechanics.● 4-terminal method for accurate measurement
SPECIFICATIONSDisplaySampling RatePower SupplyFuseCE MarkDimensionsWeightAccessories
::::::::
4199 count LCD, Maximum reading 41992 times / sec 1.5V R6P or AA Batteries (x 8)F22 (0.5A / 600V) x 1EN61326-1140(H) x 130(W) x 70(D) mm600gHolster, 100-71 Test Leads (x 1 set),1035 Carrying Case, 1.5V R6P Batteries (x 8)
Car Measurement with SK-3800
Low resistance measurement ofthe hybrid vehicle motor
①Turn the power switch of the vehicle OFF. Remove the service plug grip.
④Set the measurement range of the SK-3800.
②Remove the inverter cover.
③ D i s c o n n e c t t h e three-phase alternating cu r ren t cab le o f t he hybrid vehicle motor from the inverter.
⑤Make the zero-adjustment for SK-3800.(Press “MEASURE” key with the test lead tips short-circuit. Then, press “0Ω ADJ ” key.)
Measurement Example (with TOYOTA Prius)※Observe the procedures in maintenance manual.
⑥Connect the test leads to the three-phase alternating current cable terminals of the hybrid vehicle motor.
⑦Read the resistance on LCD.
Advantages of SK-3800
Accurate testing with4-terminal measurementEffective for eliminating the impedance contribution of the wiring and contact resistances to ensure the accurate measurement.
Clip-on test lead tips
Large backlit LCD
Hands-free measurement without holding the test leads.
Covered with rubber holster for slip-proof and to prevent scratching on the vehicle body.
Rubber holster for shock protection
Color-coded input terminals and test plugsEasy plug-in to the input terminals by colors. Also helpful in preventing the wrong insertion.
Comparator FunctionHigh/Low judgement by LCD display and buzzer comparing with the preset reference value.
Ω
Range
40mΩ400mΩ4Ω40Ω400Ω4kΩ40kΩ
Accuracy
±0.3%rdg±3dgt
±0.3%rdg±2dgt
Resolution
10μΩ100μΩ1mΩ10mΩ100mΩ1Ω10Ω
Test Current
200mA
2mA
1mA20μA10μA
MaximumApplied Power1.7mW17mW17μW170μW420μW1.7μW4.2μW
Open CircuitVoltage
<5VLOW Ω / Ω
Low resistance measurement is required for hybrid vehicle motor and generator if the DTC code “P0A78 (Drive Motor "A" Inverter Performance) is detected.
In this testing, the resistance to be measured is very low around 100mΩ.
2-terminal measurement like normal Digital Multimeters is not suitable for this level of resistance due to the errors of impedance contribution of the wiring and contact resistances.
SK-3800 can eliminate such errors by 4-terminal measurement which assures the accurate testing.
Clam
p Meters
Insulation Testers / Earth TesterD
igital M
ultim
etersA
nalo
g Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
8
φ20mm
ConductorDiameter
Low Current DC Clamp Meter
Quick and Easy Dark Current Measurement Just Clamping-On
FEATURES●Automatic Zero-Adjustment function to adjust LCD
indications into 0±1 digit when powered on.●Stable LCD reading even in low current.●Shielded clamp core prevents external noise or effect
of external magnetic field.
SK-7830
DC
4000mADC
40A/200A DIFF AUTOZERO APODISP
HOLD
DCCurrent
Functions
Accuracyfrom 5mA0A to 100A101A to 200A
±1.5%rdg±5dgt
±3.0%rdg±5dgt
Range4000mA40A200ADifference, Power-on Initialize, Display Hold, Auto Power OFF
SPECIFICATIONSDisplaySampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:::::::::
4000 count LCD, Maximum reading 405064 times / sec (Display : 1 time / sec) Manual (4000mA), Auto (40A / 200A)φ20mm Max. 1.5V R6P or AA Batteries (x 2) CATⅢ300V and EMC203(H) x 61(W) x 30(D) mm230g 1011 Carrying Case (x 1)1.5V R6P Batteries (x 2)
Dark Current Measurement
Car Measurement with SK-7830
Dark Current : mA-level low current that is used after turning off the engine by such as car security system or audio settings back-up. Too much dark current causes battery runs out, but its measurement was difficult. SK-7830 solved this problem and make it quick and easy.
③Clamp-on a minus cable of car battery.
④Read the measurement value. If it is higher than the specified value, check ① once again.
Trigger
4000mA Range
Car Alternator's Charging Current Measurement
Car Alternator : Engine generator that outputs DC electricity. Measuring its charging current is effective to find the trouble that might cause battery runs out or battery damages.
①Set the switch to 40A/200A range without touching the trigger lever, not to open the clamp jaws.
②Clamp B-terminal cable from car alternator.③Start the engine.④Read the measurement value on LCD.※Alternator is judged normal if LCD shows 20A
to 40A after the engine started, then slowly turn down.If the current remain unchanged or high current remain displayed, the alternator might be damaged.
Trigger
40A/200A Range
①Leave the engine turned off for about 15 minutes. All electric components (headlights or lamps) must be turned off.②Set the switch to 4000mA range without
touching the trigger lever, not to open the clamp jaws.
Advantages of SK-7830
For Car Maintenance Wide range of DC current measurement is possible from 4000mA to 200A range.
Stable ReadingEven in low current measurement, SK-7830's LCD reading is always stable.Generally, low current measurement value is hard to read due to its instability. SK-7830 solved this problem by its own internal processing system to minimize reading-instability.
Small-Sized Clamp Head SK-7830's small clamp head assures easy clamping even for narrow conductors such as the cables around car engine.
Power-On InitializeAutomatic Zero-Adjustment function to adjust LCD indications into 0±1 digit when powered on.
Newly-Developed External-Noise-PreventableCore MechanismShielded clamp core prevents external noise or effect of external magnetic field.
DC4000mA
DC40A/200A
φ20mm Max
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
AC / DC Digital Clamp Meters
Car Measurement with SK-7661
Alternatorcharging currentClamp-on the B-terminal of the alternator.
MAXM I N
Handy-size Clamps with Efficient Functions
AC/DC
VAC/DC
400A DIFFDUTY
%HzΩfor DC Currentmeasurement
AUTOZERO APODISP
HOLD
φ27mm
ConductorDiameter
SPECIFICATIONSDisplay
Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:
::::::::
4000 count LCD, Maximum reading 40503 times / secAuto Rangingφ27mm Max. 1.5V R03 or AAA Batteries (x 2)CATⅢ 300V, CATⅡ 600V and EMC 170(H) x 58(W) x 27(D)mm 160g100-63 Test Leads (x 1 set)1015 Carrying Case (x 1)1.5V R03 Batteries (x 2)
Accuracy±1.5%rdg±3dgt40 to 200A201 to 300A301 to 400A±1.5%rdg±5dgt (50/60Hz)40 to 200A201 to 300A301 to 400A±0.2%rdg±2dgt±1.0%rdg±3dgt
±1.0%rdg±2dgt
±1.5%rdg±5dgt (40 to 400Hz)
±0.2%rdg±2dgt
±1.0%rdg±3dgt±1.5%rdg±5dgt±0.7%rdg±3dgt±1.2%rdg±5dgt±3.0%rdg±5dgt±1.5%rdg±5dgt±5.0%rdg±5dgt±1.5%rdg±5dgt
±5.0%rdg±5dgt
±1.5%rdg±5dgt±3.0%rdg±3dgt±4.0%rdg±3dgt
±2.0%rdg±3dgt (50/60Hz)±4.0%rdg±5dgt (50/60Hz)±5.0%rdg±5dgt (50/60Hz)
*Frequency Characteristic (40 to 400Hz) : 40A Range (0.5 to 9A) add 1.5% (10 to 40A) add 0.5% 400A Range add 1.0%
A / A Hz
V / VHz / %
Range40A
400A
40A
400A
5Hz to 1kHz400mV4V40V400V600V4V40V400V600V5Hz to 49.99kHz5% to 95%400Ω4kΩ40kΩ400kΩ4MΩ40MΩ400ΩBuzzer Sound : Approx. 50Ω or less0 to 1.5VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF(±5.0%rdg±10dgt)MAX / MIN Difference, Power-on Initialize (for DC Current measurement),Display Hold, Auto Power OFF
DCVoltage
ACVoltage
DCCurrent
ACCurrent*
Frequency
Frequency
Duty Cycle
Resistance
Continuity Test
Functions
Diode Test
Capacitance
9
Battery voltageContact test lead pins to the battery. Black to minus, red to plus.
OPTIONAL ACCESSORIES940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin
944 Test Pin946 Battery Clip
OthersCapacitor checkGenerating voltage checkResistance check
Water temperature sensorContinuity testDiode test
Car Measurement with SK-7682
Easy-to-grip handheldclampEasy-to-grip size with 196mm length and 180g weight. Can be used like an industrial tool.
Easy clamping even fornarrow conductorsEasy-to-clamp compact clamp jaws at φ19mm even for narrow conductors in car engine room.
Focused on High-Flexibility
φ19mm
ConductorDiameter
V / VHz / %
A / A Hz
Accuracy±1.5%rdg±3dgt40 to 200A201 to 400A±1.5%rdg±5dgt36 to 200A201 to 400A±0.2%rdg±2dgt±1.0%rdg±3dgt
±1.0%rdg±2dgt
±1.5%rdg±5dgt
±0.2%rdg±2dgt
±0.5%rdg±5dgt
±2.0%rdg±3dgt±4.0%rdg±3dgt
±2.0%rdg±5dgt±5.0%rdg±5dgt
Range40A
400A
40A
400A
5Hz to 1kHz400mV4V40V400V600V4V40V400V600V1Hz to 49.99kHz0% to 99.9%MAX / MIN, Peak Hold, Difference,Power-on Initialize (for DC Current measurement),Display Hold, Auto Power Off
MAXM I N
PEAKHOLD
AC/DC
VAC/DC
400ADISPHOLDDIFF
HzTRUERMSAPO
DUTY
%for Voltagemeasurement
for DC Currentmeasurement
AUTOZERO
FEATURES●Usable for Automotive Measurements.●Peak Current and Peak Voltage.●Max / Min and Difference Measurements.
DCVoltage
DCCurrent
ACCurrent
Frequency
Frequency
Duty Cycle
ACVoltage
Functions
SPECIFICATIONSDisplay
Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:
::::::::
4000 count LCD, Maximum reading 40503 times / sec Auto Rangingφ19mm Max. 1.5V R6P or AA Batteries (x 2) CATⅢ 300V and EMC196(H) x 59(W) x 30(D) mm180g100-57 Test Leads (x 1 set)940 Alligator Clips (x 1 set)1011 Carrying Case (x 1)1.5V R6P Batteries (x 2)
OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set948 Alligator Clips793 Coil-Type Contact Pin944 Test Pin946 Battery Clip φ19mm Max
Clam
p Meters
Insulation Testers / Earth TesterD
igital M
ultim
etersA
nalo
g Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
Versatile Clamp Meter, Compactly Designed
SK-7718
Resistance
Functions
±1.5%rdg±5dgt±3.0%rdg±5dgt
±1.5%rdg±3dgt±3.0%rdg±3dgt
A / A Hz
V / V Hz・%
APOMAXM I N
PEAKHOLD
AC/DC
VAC/DC
1000ADISPHOLDDIFF
ΩTRUERMS
DUTY
%Hz
for DC Currentmeasurement
AUTOZERO
φ35mm
ConductorDiameter
FEATURES●AC / DC 1000A Measurements● "Power-On Initialize" (auto zero adjustment) for DCA.●MAX / MIN, Difference, Peak Hold●Dust-proof case is used to protect the tester from dust damage.
DCVoltage
ACVoltage
DCCurrent
ACCurrent
Frequency
Frequency
Duty Cycle
SPECIFICATIONSDisplay
Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:
::::::::
4000 count LCD, Maximum reading 99993 times / secAuto Rangingφ35mm Max. 9V 6F22 Battery (x 1)CATⅢ 600V and EMC193(H) x 60(W) x 34.5(D) mm300g 100-57 Test Leads (x 1 set)1012 Carrying Case (x 1)9V 6F22 Battery (x 1)
OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips948 Alligator Clips
793 Coil-Type Contact Pin944 Test Pin946 Battery Clip
DustProof
Simple WaterResistant
AC / DC Digital Clamp Meters
Continuity Test
Diode Test
Capacitance
Range400A
1000A
400A
1000A
1Hz to 1kHz4V40V400V600V400mV4V40V400V600V1Hz to49.99kHz10% to 90%400Ω4kΩ40kΩ400kΩ4MΩ40MΩ400Ω (Buzzer Sound : Approx. 50Ω or less)0 to 1.5VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF(±5.0%rdg±10dgt)Peak Hold, MAX / MIN, Difference,Power-on Initialize (for DC Current measurement),Display Hold, Auto Power OFF
Accuracy±1.5%rdg±5dgt400 to 600A601 to 1000A±1.5%rdg±3dgt400 to 600A601 to 1000A±0.2%rdg±2dgt
±1.0%rdg±5dgt (40Hz to 400Hz)
±1.0%rdg±3dgt
±0.2%rdg±2dgt
±2.0%rdg±2dgt±1.5%rdg±5dgt
±1.0%rdg±3dgt
±4.0%rdg±5dgt±6.0%rdg±5dgt
±5.0%rdg±5dgt
10
Starter current measurement
①Set the selector switch to
DC-A range.
②Press and hold Peak key to
enter Peak Hold mode.
③Clamp-on the minus cable of the car battery.
④Start the car engine.
⑤Read the measurement value on LCD.
Advantages of SK-7718
Display HoldCan freeze the readings on LCD. Useful for reading the
unstable measurement values.
DifferenceDisplay the relative value during the measurement.
Auto Power OffThe unit turns off automatically after 12 minutes of last
operation. Effective to conserve the battery life (cancelable).
MAX/MINDisplay the maximum and minumum values during the
measurement.
Dust & Drip ProofCan protect the unit from dust and water-drip affects.
Suitable for the various electric components testsAlternator ChargingCurrent MeasurementStarter Current MeasurementBattery Voltage Measurement
Other application : Water temperature sensor test, Continuity test, Diode test,
Noise-prevention capacifor check, Resistance check
MAX 1000A MeasurementUp to 1000A measurement for DC/AC current.
Applicable for high displacement vehicles.
Peak HoldFor starter current measurement. Can display the peak
current in the certain period of time.
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
AC / DC Digital Clamp Meters
11
SK-7722
φ36mm
ConductorDiameter
Alternator Test - Charging Current & Generating Voltage
①Insert test lead plugs to the input terminals.
②Set the selector switch to DCA + DCV range.
⑤Start the engine, and clamp-on the B-terminal of the alternator.
③Contact test lead pins to the battery. Black to minus, red to plus.
④LCD shows the battery voltage when stopping the engine.
⑥Run up the engine around 2000 rpm. Load the maximum electricity by turning on the electric components, such as headlights.
※For charge control vehicles, alternator might not generate the power.
Simple WaterResistant
SK-7720 /SK-7722
PULSEWIDTH
MAXM I N
PEAKHOLD
2 Channel Measurements on Dual Display LCD and Oscilloscope Connection
AC/DC
VAC/DC
1000ADISPHOLDDIFF
DUTY
%HzΩ
TRUERMS
OUTPUT
SK-7722
OPTIONAL ACCESSORIES818-02 Temperature Probe817-03 to 817-25 Temperature Probes922 DC Adapter Cable (SK-7722)930 Output Cord for Recorder(SK-7722)
100-41 Test Lead Kit
FEATURES●Two different elements can be measured at once and
read on a bigger Dual Display LCD.●Analog Output Terminal for an Oscilloscope or Recorder (SK-7722).●Dust-proof case is used to protect the tester from dust damage.
Resistance
TemperatureFunctions
Range
400A / 1000A
Range400V650V
400A / 1000A
10.0Hz to 4000Hz0.0% to 99.9%1.0mS to 999.9mS
400V / 650V
10.0Hz to 4000Hz0.0% to 99.9%1.0mS to 999.9mS4000Ω20kΩ-30℃ to 150℃Peak Hold, MAX / MIN, Difference, Display Hold, Output Terminal (SK-7722)
Accuracy400.0A400 to 600A601 to 1000AAccuracy±1.0%rdg±3dgt±1.0%rdg±1dgt
400.0A400 to 600A601 to 1000A±0.5%rdg±1dgt±3.0%rdg±3dgt±0.5%rdg±3dgt±1.0%rdg±3dgt (50Hz to 60Hz)±1.5%rdg±3dgt (40Hz to 400Hz)±0.5%rdg±1dgt±3.0%rdg±3dgt±0.5%rdg±3dgt±1.0%rdg±3dgt±1.0%rdg±1dgt±1.0%rdg±3dgt
Range40V250V
Accuracy±1.0%rdg±3dgt±1.0%rdg±1dgt
40V / 250V±1.0%rdg±3dgt (50Hz to 60Hz)±1.5%rdg±3dgt (40Hz to 400Hz)
±1.5%rdg±3dgt±1.5%rdg±1dgt±3.0%rdg±3dgt
50Hz to 60Hz±1.5%rdg±3dgt±1.5%rdg±1dgt±3.0%rdg±3dgt
40Hz to 400Hz±2.5%rdg±3dgt±2.5%rdg±1dgt±4.0%rdg±3dgt
A + V
A + Hz
V + Hz
SK-7720 SK-7722
DCVoltage
ACVoltage
DCCurrent
ACCurrent
FrequencyDuty CyclePulse Width
FrequencyDuty CyclePulse Width
SPECIFICATIONSDisplaySampling Rate
Range SelectionConductor DiameterPower SupplyDimensionsWeightAccessories
::
::::::
4000 count LCD, Maximum reading 999915 times / sec. (each channel), 3.75 times / sec. for A+V measurements in ordinary mode.Auto Rangingφ36mm Max. 9V 6F22 or NEDA 1604 Battery (x 1)200(H) x 64(W) x 33(D) mm310g100-57 Test Leads (x 1 set)1007 Carrying Case (x 1), 9V 6F22 Battery (x 1)
DustProof
100-62 Test Lead Set940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin944 Test Pin946 Battery Clip
Two different elements can be measured at once and read on a bigger Dual Display LCD
Temperare check of air conditioner outlet※818 -02 tempearture probe (option) required.
Starter current and battery voltage measurements
Alternator measurement : Charging current and generating voltage
Advantages of SK-7720 / 7722
Clam
p Meters
Insulation Testers / Earth TesterD
igital M
ultim
etersA
nalo
g Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
12
FEATURES● For various automotive measurements.
Battery voltage / RPM* / Injection pulse width /Charging current for alternator (with optional clamp adapter) /Temperature
*Except for rotary engine, diesel engine, and vehicle equipped with MSD or MDI systems.
● Large LCD with backlight and bar graph.●Display hold, Auto power off functions.●Error input warning.●Equipped with holster and hard carrying case.
::
:::
:
:::
SPECIFICATIONSDisplaySampling Rate
Range SelectionPower SupplyFuse
CE Mark
Dimensions WeightAccessories
6000 count LCD (Numerical) 5 times / sec(Bargraph) 40 times / secAuto / Manual Ranging1.5V R03 or AAA Batteries (x 2)F20 (0.63A/500V) x 1 F32 (6.3A/500V) x 1 V : CATⅡ 1000V, uA/mA/A : CATⅡ 450Vand EMC 161(H) x 80(W) x 50(D) mm 340gHolster, 100-66 Test Leads (x 1 set)653 RPM Sensor (for Direct Ignition)654 RPM Sensor (for High Tension Code)818-02 Temperature Probe943 Alligator Clip, 1024 Carrying Case1.5V R03 Batteries (Installed) x 2Spare Fuses F20 (0.63A/500V) &F32 (6.3A/500V) x 1 each
Extremely versatile Automotive Digital Multimeter
KT-2021
Automotive Digital Multimeters
Range Resolution
Resolution
Resolution
Accuracy
Accuracy
Accuracy
: DC/AC 40A/400A: DC/AC 100mA/mV(40A Range) DC/AC 1A/mV(400A Range): ±1.5% to 7.0%rdg±0.5mV: 1.5V R6P or AA Batteries (x2): φ19mm Max. : CAT Ⅱ 300V, CATⅠ600V, class 2 and EMC : 180(H) x 43(W)) x 31(D)mm: 210g: 145cm
RangeOutput
AccuracyPower SupplyConductor DiameterCE Mark
Dimensions WeightCable length
For engine speed measurement of direct ignition engine that is equipped for the most of gas-powered car recently.
RPM Sensor(Accessories)
For engine speed measurement by clamping on the high tension cord.
RPM Sensor(Accessories)
OPTIONAL ACCESSORIES660 AC / DC Clamp Adapter817-03 to 817-25 Temperature Probes100-41 Test Lead Kit100-62 Test Lead Set944 Test Pin946 Battery Clip793 Coil-Type Contact Pin
Velcro tape tofix the sensor
KT-2021
Automotive DMM
Spark Plug
MODEL 654
Equipped with anUseful Carrying Case
AC/DC
VAC/DC
ABARGRAPH
APODISPHOLD
RNGHOLDHzΩ DUTY
%PULSEWIDTH
DWELLANGLERPM Error input
warning
DCVoltage
ACVoltage
DCCurrent
ACCurrent
Resistance
Functions
Accessories, Optional Accessories
The charge current of alternator can be measured just clamping.
AC / DC Clamp Adapter(Optional Accessories)
MODEL 653
Direct Ignition Coil
KT-2021
Automotive DMM
Velcro tape
±0.4%rdg±3dgt±0.3%rdg±3dgt
±0.4%rdg±3dgt
±0.7%rdg±3dgt±2.0%rdg±5dgt(50Hz to 500Hz)
±2.0%rdg±5dgt(50Hz to 500Hz)
±2.2%rdg±5dgt(50Hz to 500Hz)
±0.7%rdg±3dgt±0.5%rdg±3dgt±0.7%rdg±3dgt±0.5%rdg±3dgt±0.7%rdg±3dgt±0.5%rdg±3dgt±2.2%rdg±5dgt±2.0%rdg±5dgt±2.2%rdg±5dgt±2.0%rdg±5dgt±2.2%rdg±5dgt±1.2%rdg±5dgt
±0.5%rdg±6dgt
±0.5%rdg±3dgt
±0.8%rdg±4dgt±1.0%rdg±5dgt±1.5%rdg±5dgt
60mV600mV6V60V600V1000V60mV600mV6V60V600V
1000V
600μA6000μA60mA600mA6A10A600μA6000μA60mA600mA6A10A
600Ω6kΩ60kΩ600kΩ6MΩ60MΩ
Bargraph, Range Hold, Display Hold, Auto Power Off, Backlight,Error input warning
Range
Range
0.01mV0.1mV1mV10mV100mV1V0.01mV0.1mV1mV10mV100mV
1V
0.1μA1μA0.01mA0.1mA1mA10mA0.1μA1μA0.01mA0.1mA1mA10mA
0.1Ω1Ω10Ω100Ω1kΩ10kΩ
≒10MΩ,50pF
≒10MΩ,50pF
Voltage Drop
0.25mV /μA
2.5mV / mA
0.03V / A
0.25mV /μA
2.5mV / mA
0.03V / A
Open Circuit Voltage
0.45V DC
Input Impedance RangeFunction Accuracy
Frequency ±0.1%rdg±3dgt
10Hz to 10kHz
10Hz to 50kHz
45Hz to 1kHz
6V60V600V1000V
0.5V rms5V rms50V rms500V rms
Input Sensitivity
RangeFunction
IP-RPM240 to 20000RPM120 to 10000RPM60 to 5000RPM
RPM4RPM2RPM2-M
±0.2%rdg±20dgt
Accuracy
AccuracyRange
Diode Test±1.0%rdg±3dgt1.000V
Open Circuit Voltage : <1.6V DC
Test Current0.50mA
ResolutionRange
Temperature1°C1°F
-50℃ to 1000℃-58°F to 1832°F
Accuracy±0.5%rdg±3dgt ±0.5%rdg±6dgt
ResolutionRange
Capacitance
0.001μF0.01μF0.1μF1μF
6.000μF60.00μF600.0μF2000μF
Accuracy±2.0%rdg±5dgt
±3.5%rdg±5dgt
±4.0%rdg±5dgt
AccuracyRange±1.2°/krpm±1dgt0° to 360° 1,2,3,4,5,6,8,10,12
Selectable Number of Cylinders
IG-RPM60 to 20000RPM30 to 10000RPM15 to 5000RPM
RPM4RPM2RPM2-M
±0.2%rdg±20dgt
Dwell Angle
Buzzer Sound : Approx. 10 to 200Ω or lessContinuity Test
±0.04%/krpm/cyl±2dgt 0% to 100% 1,2,3,4,5,6,8,10,12Duty CycleAccuracyRange
±0.05ms±1dgt0.05ms to250.0ms
Fuel InjectionPulse Width
±0.04%/krpm±2dgt0% to 100%Duty Cycle
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
13
Automotive Digital Multimeters
Motorcycle Multimeter
AC/DC
VAC/DC
ARNGHOLDΩ
SPECIFICATIONSDisplaySampling RateRange SelectionPower Supply FuseCE MarkDimensions WeightAccessories
:::::::::
2000 count LCD, Maximum Reading 1999 2 times / secAuto / Manual Ranging1.5V R6P or AA Batteries (x 2)F12 (0.3A / 250V) x 1, F18 (15A / 250V) x 1CATⅡ 300V and EMC160(H) x 75(W) x 34(D) mm 180g100-57 Test Leads (x 1 set) 650 RPM Sensor (x 1), 940 Alligator Clips (x 1 set) 995 Carrying Case (x 1), 1.5V R6P Batteries (x 2) Spare Fuses F12 (0.3A / 250V) &F18 (15A / 250V) x 1 each
DISPHOLD
OPTIONAL ACCESSORIES660 AC / DC Clamp Adapter100-41 Test Lead Kit100-62 Test Lead Set948 Alligator Clips
944 Test Pin946 Battery Clip793 Coil-Type Contact Pin
APSRPM
DCVoltage
ACVoltage
DCCurrent
ACCurrent
Functions
Resistance
Range Resolution Accuracy Input Impedance200mV2V20V200V300V
0.1mV1mV10mV100mV1V
±1.2%rdg±2dgt
≧100MΩ
≒11MΩ
≒10MΩ
RPM
Range Resolution Accuracy Sparks12000RPM6000RPM
10RPM ±2%rdg±10dgt1 spark / 1 revolution2 sparks / 1 revolution
2V20V200V300V
1mV10mV100mV1V
±2.3%rdg±7dgt≒11MΩ
≒10MΩ
Range Resolution Accuracy Voltage Drop20mA
20A
10μA
10mA
±1.0%rdg±4dgt0 to 10.00A±1.5%rdg±2dgt10.01 to 20A ±2.5%rdg±4dgtt
≦0.5V
<0.5V
20mA
20A
10μA
10mA
±2.0%rdg±8dgt0 to 10.00A±2.0%rdg±7dgt10.01 to 20A±3.0%rdg±10dgt
<0.5V
Range Resolution Accuracy Test Current
Range Resolution Test Current
200Ω2kΩ20kΩ200kΩ2MΩ20MΩOpen Circuit Voltage : approx. ≦0.43V
0.1Ω1Ω10Ω100Ω1kΩ10kΩ
±1.5%rdg±4dgt
±1.8%rdg±4dgt±5.0%rdg±4dgt
≦0.4mA≦0.2mA≦30μA≦3μA≦0.3μA≦0.03μA
Range Hold, Display Hold, Auto Power Save
Continuity Test 2kΩ (Buzzer Sound : Approx. 500Ω or less)
Diode Test 2VOpen Circuit Voltage : ≦1.7V
1mV ≦0.6mA
FEATURES●RPM, 20mA and 20A DC / AC, and Continuity Tests. (Non-usable for Harley-Davidson V-twin engine 45°angle)● 200A DC / AC measurements by optional 660 Clamp
Adapter.
OPTIONAL ACCESSORIES940 Alligator Clips948 Alligator Clips792R Straight Test Pin (Red)944 Test Pin
946 Battery Clip793 Coil-Type Contact Pin1026 Carrying Case
FEATURES●Current measurement up to AC / DC 400mA.●Penlight and backlight LCD.
SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyFuseCE MarkDimensions WeightAccessories
4000 count LCD 3 times / sec.Auto Ranging1.5V LR44 Battery (x 2)F22 (0.5A / 600V) x 1CATⅢ 600V and EMC 209(H) x 38(W) x 32(D) mm Approx. 110g (include battery)100-68 Test Lead (Black) (x 1)1.5V LR44 Batteries (x 2)780 Red Insulation Cap (x 1) 781 Test Lead Insulation Cap (Black) (x 1)
:::::::::
SK-6597
Improved probe tester with enhanced functions
SK-6597
AC/DC
VAC/DC
A APODISPHOLDHzΩ DUTY
%PEN
LIGHTMAXM I N DIFF
Digital Multimeters (Probe Tester)
Range400mV4V40V400V600V
4V40V400V600V1Hz to 100kHz0.0% to 99.9%Range40mA400mA40mA400mA10Hz to 100kHzRange400Ω4kΩ40kΩ400kΩ4MΩ40MΩOpen Circuit Voltage : ≒0.44V400Ω (Buzzer Sound : Approx. 50Ω or less)1VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF MAX / MIN, Display Hold, Difference, Auto Power Off,Penlight and Backlight
Resolution0.1mV1mV10mV100mV1V
1mV10mV100mV1V0.001 to 100Hz0.1%Resolution10μA100μA10μA100μA0.01 to 100HzResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Accuracy
50Hz to 500Hz
±1.5%rdg±5dgt
Accuracy
Accuracy
Input Impedance≧100MΩ≒11MΩ
≒10MΩ
≒11MΩ
≒10MΩ
Burden Voltage<0.1V<0.6V<0.1V<0.6V
Test Current≦0.2mA≦50μA≦5μA≦0.5μA
≦50nA
±0.5%rdg±3dgt
±1.0%rdg±3dgt
±1.0%rdg±2dgt
±1.5%rdg±7dgt
±0.2%rdg±2dgt
±0.2%rdg±2dgt±0.5%rdg±5dgt
±1.5%rdg±4dgt
±1.0%rdg±3dgt
±5.0%rdg±3dgt±7.0%rdg±3dgt
±5.0%rdg±3dgt
±5.0%rdg±10dgt
DCCurrent
AC Current40Hz to 500Hz
DCVoltage
ACVoltage
Resistance
Functions
Continuity Test
Capacitance
Diode Test
Frequency
Frequency
Duty Cycle
≦0.7mA
Advantages of SK-6597
Easy-to-usepen-type testerEasily to be tested in car engine room.
Penlight andbacklight LCDBrightly i l luminate test points and display even in the dark place.
Current measurementCan measure up to 400mA AC/DC.
Easy-to-read large LCD (compared to the existing model)
Clear buzzer soundEasy-to-hear buzzer sound even in noisy conditions.
Replaceable Test Pin and Test LeadEasy replacement without any tools.
・Screw-in type Test Pin ・Plug-in type Test Lead
Clam
p Meters
Insulation Testers / Earth TesterD
igital M
ultim
etersA
nalo
g Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
14
Resolution100μV1mV10mV100mV/1V1mV10mV/100mV1V0.001 to 100Hz0.1%Resolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Input Impedance≧100MΩ≒11MΩ
≒10MΩ
≒11MΩ
≒10MΩ
Test Current≦0.2mA≦50μA≦5μA≦0.5μA
≦50nA
≦0.7mA
OPTIONAL ACCESSORIES940 Alligator Clips948 Alligator Clips792R Red Straight Test Pin
944 Test Pin946 Battery Clip793 Coil-Type Contact Pin
FEATURES●Smart Design for Easy of Use.● Fully line-upped function for useful measurements.●MAX / MIN, and Difference Measurements are available.
DCVoltage
ACVoltage
Resistance
Functions
SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyCE MarkDimensions WeightAccessories
::::::::
4000 count LCD 3 times / sec.Auto Ranging3V CR2032 Battery (x 1)CATⅢ 600V and EMC 179(H) x 28(W) x 20(D) mm 60g100-52 Test Leads (x 1), 1006 Carrying Case (x 1)3V CR2032 Battery (x 1)
Multi-Functional and Versatile Probe Tester
AC/DC
V APODISPHOLD
MAXM I N DIFF
DUTY
%HzΩ
Digital Multimeters (Probe Tester)
FrequencyDuty Cycle
Continuity Test
Diode Test
Capacitance
Range400mV4.0V40V400V/600V4.0V40V/400V600V1Hz to 100kHz0 to 99.9%Range400Ω4.0kΩ40kΩ400kΩ4.0MΩ40MΩOpen Circuit Voltage : ≒0.44V
400Ω (Buzzer Sound : Approx. 60Ω or less)
1VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF (±5.0%rdg±10dgt)MAX / MIN, Difference, Display Hold, Auto Power Off
Accuracy
±0.5%rdg±3dgt
±1.0%rdg±3dgt
±1.5%rdg±5dgt
±0.2%rdg±2dgt±0.5%rdg±5dgtAccuracy±1.5%rdg±4dgt
±1.0%rdg±3dgt
±5.0%rdg±3dgt±7.0%rdg±3dgt
±5.0%rdg±3dgt
For Hybrid and Electric vehicles maintenances
SK-3502AC/DC
VDISPHOLD
DATAMEMO APSCOMP
125V200MΩ
250V2000MΩ
500V2000MΩ
1000V2000MΩ Ω
LOW
Digital Insulation Tester
SPECIFICATIONSDisplaySampling RatePower SupplyFuseCE MarkDimensionsWeightAccessories
::::::::
4000 count LCD, Maximum reading 40002 times / sec 1.5V R6P or AA Batteries (x 8)F22 (0.5A / 600V) x 1CATⅣ 600V CLASSⅡand EMC120(H) x 130(W) x 70(D) mm600g100-61 Test Leads (x 1 set), 945B Black Alligator Clip (x 1)1016 Carrying Case (x 1), 1.5V RW6P Batteries (x 8)Spare Fuse F22 (0.5A / 600V) x 1 (built-in)
SimpleDust Proof
SimpleWater Resistant
OPTIONAL ACCESSORIES766B Black Test Prod (with 767B Black Test Pin)940R Red Alligator Clip948R Red Alligator Clip
125V 250V 500V 1000V200MΩ
5MΩ0.200 to 10 MΩ
0 to 0.199 MΩ, 10.01 to 200.0 MΩ
2000MΩ50MΩ
0.200 to 100 MΩ
0 to 0.199 MΩ, 100.1 to 2000 MΩ
±3%rdg±4dgt
±5%rdg±5dgt
Comparator, Data memory, Timer, Live wire warning, Safety lock, High voltage warning, Automatic discharge,Zero-ohm adjustment, Backlight, Display hold, Auto power save
20.00Ω
200mA or more
DCV / ACV fixed (0V to 600V)
±3%rdg±5dgt
6V or more
±3%rdg±5dgtApprox. 660kΩ
400.0Ω
Approx. 10mA
AUTO (10V to 600V)
Rated Test Voltage (DC)Max. Effective ReadingCenter Reading1st effective rangeAccuracy2nd effective range
AccuracyDisplay Range (Auto-ranging)Accuracy (After 0Ω Adjustment)Measurement CurrentOpen Circuit VoltageRangeAccuracyInput Resistance
InsulationResistance
LowResistance
AC / DCVoltage
Functions
Car Measurement with SK-3502
Insulation Resistance Testfor Hybrid VehibleWhy measuring this?Checking insulated condition of motor or cable is essential for hybrid vehicles to prevent electric shock accident caused by leakage of high-voltage circuit.
① Insert test leads and alligator clips to the input tereminals.②Set function switch to
500V.
⑤Clip the metal part of the vehicle with the black alligator clip to get the grounding.
③Detach service plug.④Remove inverter cover,
and detach motor cable and generator cable from the inverter.
⑥Press Measure key with contacting the test pin on the terminal.
⑦Read the measurement value on LCD.
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
15
Focusing on Easy of Use Digital Tachometer
SK-8401 DIGITAL TACHOMETERFEATURES●Quick and Easy Measurement.●Measurable with Various Types of Engines. (except for rotary engine, diesel engine, and vehicle
equipped with MSD or MDI systems.)
SPECIFICATIONSDisplayPower Supply CE MarkDimensions WeightAccessories
::::::
Maximum Reading 9999 1.5V R6P or AA Batteries (x 2)EMC test passed148(H) x 83(W) x 33(D) mm 180g653 RPM Sensor (x 1)995 Carrying Case (x 1)1.5V R6P (AA) batteries x 2
RPM
OPTIONAL ACCESSORIES650 RPM Sensor (for High Tension Cord)
rpmRange100 to 9999 rpmDisplay Hold, Auto Power Off
Resolution1 rpm
Accuracy±0.2%rdg±10rpm
Maximum. Input10000 rpm
DISPHOLD APO
Digital Tachometer
Functions
Quick and Easy Measurement
Measurement of Direct Ignition Engine
Use 653 RPM Sensor (provided)
Sensor head is fixable by using velcro tape attached.
Measurement of High Tension CodeType Engine
Use 650 RPM Sensor (option)
MODEL 653
Direct ignition coil
Velcro tape
SHIFT DH
SK-8401
DISPLAYHOLD POWER
1 2 HI(1Sec<)
DIGITALTACHOMETER
Spark Plug
MODEL 650
SHIFT DH
SK-8401
DISPLAYHOLD POWER
1 2 HI(1Sec<)
DIGITALTACHOMETER
O2 Sensor Checker
Deterioration level of O2 sensor can be checked easily by bar-graph
FEATURES●Deterioration level of O2 sensor can be checked easily
by bar-graph●Rich, Lean, Average voltages and Cycle are displayed
respectively.●Simulated sensor signal output is available.
SK-8402 O2 SENSOR CHECKER
APODISPHOLD
DCVoltage
Functions
Resolution
1mV
10mV
Accuracy0 to 200mV:±1.5%rdg±10dgt 201 to 999mV:±1.5%rdg±5dgt ±1.5%rdg±5dgt
Range
999mV
6.00VDisplay mode changing, Simulation Test, Display Hold, Auto Power Off
Connection image
Bar-Graph Display
mV
RICH
TEST Z
APO
GOOD CHECK BAD
CHECKreplacement
recommended( )
mV
RICH
TEST Z
APO
GOOD CHECK BAD
BADreplacement
required( )GOOD
(No problem)
mV
RICH
TEST Z
GOOD CHECK BAD
APO
SK-8402
ECU in vehicle sideO2sensor
Test lead
Check harness
Connecting couplerfor O2 sensor side
Connecting couplerfor ECU side
POWER(1Sec<)
S (1Sec<)
(Test)
O2 SENSOR CHECKER
DHT5T1Z
RICH LEANDISPLAYTEST
SK-8402
TEST SEL
C
mV
AUTO DH
RICH
TEST Z T1 T5 S
AVGLEAN
APO
GOOD CHECK BAD
Yello
w
Yello
w
Blac
kBl
ack
Red
Red
Black Red
DC
V
SPECIFICATIONSDisplay
Sampling Rate
Range SelectionPower SupplyCE Mark Dimensions WeightAccessories
:
:
::::::
(Numerical) 999 count LCD,(Bargraph) 13 segments500 times/second(LCD : 1 time/second in stand-by mode)Auto Ranging1.5V R6P or AA Batteries (x 2)EMC test passed148(H) x 83(W) x 33(D) mm 220g100-65 Test Lead (x 1 set) 911Check Harness (x 1)947B Black Alligator Clip (x 1)795 Test Pins: Red & Black (x 1 set)1030 Carrying case (x 1)1.5V R6P Batteries (x 2)
SK-8402 is the O2 Sensor Checker for the O2 sensor of Zirconia, Titania 1V/5V. SK-8402 can not check deterioration judgment of A/F (air-fuel ratio) Sensor or Rear O2 Sensor.
Deterioration level of O2 sensor can be checked easily by bar-graph.
Clam
p Meters
Insulation Testers / Earth TesterD
igital M
ultim
etersA
nalo
g Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
16
Clamp Meters Index
Model
Display Counts
Conductor Diameter
DC Current
AC Current
DC Voltage
AC Voltage
Resistance
Frequency
Duty Cycle
Pulse Width
Continuity Test
Diode Test
Capacitance
Temperature
True RMS
Auto Ranging
Manual Ranging
MAX / MIN
Average
Peak Hold
Range Hold
Difference
Display Hold
Power-On Initialize
Comparator
Low Pass Filter
Output Terminal
External Power Supply
Dust Proof & Simple Water Resistant
Auto Power Save (Off)
4000
φ27mm
40A
400A
-40A
400A
--
400mV
4V
40V
400V
600V
4V
40V
400V
600V
400Ω4kΩ
40kΩ400kΩ4MΩ
40MΩ●●-●●●-●●---●-●● ●*1
-----●
4000
φ27mm
40A
400A
-40A
400A
--
400mV
4V
40V
400V
600V
4V
40V
400V
600V
400Ω4kΩ
40kΩ400kΩ4MΩ
40MΩ●●-●●●--●-●---●● ●*1
-----●
4000
φ19mm
40A
400A
-40A
400A
--
400mV
4V
40V
400V
600V
4V
40V
400V
600V
------●●-----●●-●-●-●● ●*1
-----●
AC / DC Digital Clamp Meters
*1 : for DC Current measurement
4000
φ35mm
400A
1000A
-400A
1000A
--
400mV
4V
40V
400V
600V
4V
40V
400V
600V
400Ω4kΩ40kΩ
400kΩ4MΩ40MΩ●●-●●●-●●-●-●-●● ●*1
----●●
SK-7718
4000
φ35mm
400A
1000A
-400A
1000A
--
400mV
4V
40V
400V
600V
4V
40V
400V
600V
400Ω4kΩ40kΩ
400kΩ4MΩ40MΩ●●-●●●--●-●--●●●●*1
----●●
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
17
Clamp Meters Index
Model
Display Counts
Conductor Diameter
DC Current
AC Current
DC Voltage
AC Voltage
Resistance
Frequency
Duty Cycle
Pulse Width
Continuity Test
Diode Test
Capacitance
Temperature
True RMS
Auto Ranging
Manual Ranging
MAX / MIN
Average
Peak Hold
Range Hold
Difference
Display Hold
Power-On Initialize
Comparator
Low Pass Filter
Output Terminal
External Power Supply
Dust Proof & Simple Water Resistant
Auto Power Save (Off)
AC / DC Digital Clamp Meters AC Digital Clamp Meters
4000
φ36mm
400A
1000A
-400A
1000A
--
400V
650V
---
400V
650V
--
4000Ω20kΩ----●●●---●●●-●-●-●●-----●-
SK-7720
4000
φ36mm
400A
1000A
-400A
1000A
--
40V
250V
---
40V
250V
--
4000Ω20kΩ----●●●---●●●-●-●-●●---●●●-
SK-7722
4000
φ27mm
---
40A
300A
-------------------------●------●------●
4000
φ27mm
---
40A
400A
--
400mV
4V
40V
400V
600V
4V
40V
400V
600V
400Ω4kΩ40kΩ
400kΩ4MΩ40MΩ●●-●●●-●●-●---●●------●
4000
φ55mm
400A
2000A
-400A
2000A
--
400mV
4V
40V
400V
600V
4V
40V
400V
600V
400Ω4kΩ40kΩ
400kΩ4MΩ40MΩ●●-●●●-●●●●-●●●● ●*1
----●●
SK-7708
*1 : for DC Current measurement
Clam
p Meters
Insulation Testers / Earth TesterD
igital M
ultim
etersA
nalo
g Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
18
Clamp Meters Index
Model
Display Counts
Conductor Diameter
DC Current
AC Current
DC Voltage
AC Voltage
Resistance
Frequency
Duty Cycle
Pulse Width
Continuity Test
Diode Test
Capacitance
Temperature
True RMS
Auto Ranging
Manual Ranging
MAX / MIN
Average
Peak Hold
Range Hold
Difference
Display Hold
Power-On Initialize
Comparator
Low Pass Filter
Output Terminal
External Power Supply
Dust Proof & Simple Water Resistant
Auto Power Save (Off)
2000
φ26mm
---2A
20A
200A
400A
200mV
2V
20V
200V
600V
2V
20V
200V
600V
200Ω2kΩ
20kΩ200kΩ2MΩ
20MΩ---●●--- ●*2
------●------●
AC Digital Clamp Meters
*2 : Two-ranges auto for ACA. *3 : mA / A : switch selection
2000
φ42mm
---2A
20A
200A
600A
200mV
2V
20V
200V
600V
2V
20V
200V
600V
200Ω2kΩ20kΩ
200kΩ2MΩ20MΩ---●●--- ●*2
------●------●
AC Leakage Clamp Meters
4000
φ24mm
---
40mA
400mA
40A
100A
-----
400V
600V
---------------- ●*3
------●-
●(with Vibration)
●---●
SK-7820
4000
φ40mm
---
40mA
400mA
40A
100A
-----
400V
600V
---------------- ●*3
------●-
●(with Vibration)
●---●
SK-7825
4000
φ27mm
---
40A
400A
--
400mV
4V
40V
400V
600V
4V
40V
400V
600V
400Ω4kΩ
40kΩ400kΩ4MΩ
40MΩ●●-●●●--●-●---●●------●
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
19
SK-7660
MAXM I N
PEAKHOLD
Handy-size Clamps with Efficient Functions
AC/DC
VAC/DC
400A
DIFF
DUTY
%HzΩ
FEATURES● 15 measurement functions in one small package.● "Power-On Initialize" (auto zero adjustment) in DCA.●Rubber-molded rotary switch and trigger.●Easy-to-clamp compact & beaked clamp head even for
narrow conductors.●True RMS and peak hold (SK-7660), MAX/MIN (SK-7661)
Accuracy±1.5%rdg±3dgt40 to 200A201 to 300A301 to 400A±1.5%rdg±5dgt (50/60Hz)40 to 200A201 to 300A301 to 400A±0.2%rdg±2dgt±1.0%rdg±3dgt
±1.0%rdg±2dgt
±1.5%rdg±5dgt (40 to 400Hz)
±0.2%rdg±2dgt
±1.0%rdg±3dgt±1.5%rdg±5dgt±0.7%rdg±3dgt±1.2%rdg±5dgt±3.0%rdg±5dgt±1.5%rdg±5dgt±5.0%rdg±5dgt±1.5%rdg±5dgt
±5.0%rdg±5dgt
±1.5%rdg±5dgt±3.0%rdg±3dgt±4.0%rdg±3dgt
±2.0%rdg±3dgt (50/60Hz)±4.0%rdg±5dgt (50/60Hz)±5.0%rdg±5dgt (50/60Hz)
*Frequency Characteristic (40 to 400Hz) : 40A Range (0.5 to 9A) add 1.5% (10 to 40A) add 0.5% 400A Range add 1.0%
SK-7660 SK-7661
OPTIONAL ACCESSORIES940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin
A / A Hz
V / VHz / %
V / VHz / %
A / A Hz
Range40A
400A
40A
400A
5Hz to 1kHz400mV4V40V400V600V4V40V400V600V5Hz to 49.99kHz5% to 95%400Ω4kΩ40kΩ400kΩ4MΩ40MΩ400ΩBuzzer Sound : Approx. 50Ω or less0 to 1.5VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF(±5.0%rdg±10dgt)Peak Hold (SK-7660), MAX / MIN (SK-7661), Difference, Power-on Initialize (for DC Current measurement),Display Hold, Auto Power OFF
for DC Currentmeasurement
AUTOZERO APODISP
HOLD
SK-7660
TRUERMS
Accuracy±1.5%rdg±3dgt40 to 200A201 to 400A±1.5%rdg±5dgt36 to 200A201 to 400A±0.2%rdg±2dgt±1.0%rdg±3dgt
±1.0%rdg±2dgt
±1.5%rdg±5dgt
±0.2%rdg±2dgt
±0.5%rdg±5dgt
±2.0%rdg±3dgt±4.0%rdg±3dgt
±2.0%rdg±5dgt±5.0%rdg±5dgt
Range40A
400A
40A
400A
5Hz to 1kHz400mV4V40V400V600V4V40V400V600V1Hz to 49.99kHz0% to 99.9%MAX / MIN, Peak Hold, Difference,Power-on Initialize (for DC Current measurement),Display Hold, Auto Power Off
MAXM I N
PEAKHOLD
Focused on High-Flexibility
AC/DC
VAC/DC
400ADISPHOLDDIFF
HzTRUERMSAPO
DUTY
%for Voltagemeasurement
φ27mm
ConductorDiameter
φ19mm
ConductorDiameter
for DC Currentmeasurement
AUTOZERO
FEATURES●Usable for Automotive Measurements.●Peak Current and Peak Voltage.●Max / Min and Difference Measurements.
DCVoltage
ACVoltage
DCCurrent
ACCurrent*
Frequency
Frequency
Duty Cycle
Resistance
Continuity Test
Functions
DCVoltage
DCCurrent
ACCurrent
Frequency
Frequency
Duty Cycle
ACVoltage
Functions
AC / DC Digital Clamp Meters
SPECIFICATIONSDisplay
Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:
::::::::
4000 count LCD, Maximum reading 40503 times / secAuto Rangingφ27mm Max. 1.5V R03 or AAA Batteries (x 2)CATⅢ 300V, CATⅡ 600V and EMC 170(H) x 58(W) x 27(D)mm 160g100-63 Test Leads (x 1 set)1015 Carrying Case (x 1)1.5V R03 Batteries (x 2)
SPECIFICATIONSDisplay
Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:
::::::::
4000 count LCD, Maximum reading 40503 times / sec Auto Rangingφ19mm Max. 1.5V R6P or AA Batteries (x 2) CATⅢ 300V and EMC196(H) x 59(W) x 30(D) mm180g100-57 Test Leads (x 1 set)940 Alligator Clips (x 1 set)1011 Carrying Case (x 1)1.5V R6P Batteries (x 2)
OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set948 Alligator Clips793 Coil-Type Contact Pin
Diode Test
Capacitance
Clam
p Meters
Insulation Testers / Earth TesterD
igital M
ultim
etersA
nalo
g Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
20
SK-7720
φ36mm
ConductorDiameter
Simple WaterResistant
AC / DC Digital Clamp Meters
SK-7720 /SK-7722
PULSEWIDTH
MAXM I N
PEAKHOLD
2 Channel Measurements on Dual Display LCD and Oscilloscope Connection
AC/DC
VAC/DC
1000ADISPHOLDDIFF
DUTY
%HzΩTRUERMS
OUTPUT
SK-7722
Resistance
TemperatureFunctions
Range
400A / 1000A
Range400V650V
400A / 1000A
10.0Hz to 4000Hz0.0% to 99.9%1.0mS to 999.9mS
400V / 650V
10.0Hz to 4000Hz0.0% to 99.9%1.0mS to 999.9mS4000Ω20kΩ-30℃ to 150℃Peak Hold, MAX / MIN, Difference, Display Hold, Output Terminal (SK-7722)
Accuracy400.0A400 to 600A601 to 1000AAccuracy±1.0%rdg±3dgt±1.0%rdg±1dgt
400.0A400 to 600A601 to 1000A±0.5%rdg±1dgt±3.0%rdg±3dgt±0.5%rdg±3dgt±1.0%rdg±3dgt (50Hz to 60Hz)±1.5%rdg±3dgt (40Hz to 400Hz)±0.5%rdg±1dgt±3.0%rdg±3dgt±0.5%rdg±3dgt±1.0%rdg±3dgt±1.0%rdg±1dgt±1.0%rdg±3dgt
Range40V250V
Accuracy±1.0%rdg±3dgt±1.0%rdg±1dgt
40V / 250V±1.0%rdg±3dgt (50Hz to 60Hz)±1.5%rdg±3dgt (40Hz to 400Hz)
±1.5%rdg±3dgt±1.5%rdg±1dgt±3.0%rdg±3dgt
50Hz to 60Hz±1.5%rdg±3dgt±1.5%rdg±1dgt±3.0%rdg±3dgt
40Hz to 400Hz±2.5%rdg±3dgt±2.5%rdg±1dgt±4.0%rdg±3dgt
A + V
A + Hz
V + Hz
SK-7720 SK-7722
OPTIONAL ACCESSORIES818-02 Temperature Probe817-03 to 817-25 Temperature Probes922 DC Adapter Cable (SK-7722)
930 Output Cord for Recorder(SK-7722)
100-41 Test Lead Kit
FEATURES●Two different elements can be measured at once and
read on a bigger Dual Display LCD.●Analog Output Terminal for an Oscilloscope or Recorder (SK-7722).●Dust-proof case is used to protect the tester from dust damage.
DCVoltage
ACVoltage
DCCurrent
ACCurrent
FrequencyDuty CyclePulse Width
FrequencyDuty CyclePulse Width
SPECIFICATIONSDisplaySampling Rate
Range SelectionConductor DiameterPower SupplyDimensionsWeightAccessories
::
::::::
4000 count LCD, Maximum reading 999915 times / sec. (each channel), 3.75 times / sec. for A+V measurements in ordinary mode.Auto Rangingφ36mm Max. 9V 6F22 or NEDA 1604 Battery (x 1)200(H) x 64(W) x 33(D) mm310g100-57 Test Leads (x 1 set)1007 Carrying Case (x 1), 9V 6F22 Battery (x 1)
DustProof
100-62 Test Lead Set940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin
Versatile Clamp Meter, Compactly Designed
SK-7718
APOMAXM I N
PEAKHOLD
AC/DC
VAC/DC
1000ADISPHOLDDIFF
Ω
TRUERMS
DUTY
%Hz
SK-7718 SK-7719 SK-7718
RNGHOLD
for DC Currentmeasurement
AUTOZERO
φ35mm
ConductorDiameter
FEATURES●AC / DC 1000A Measurements● "Power-On Initialize" (auto zero adjustment) for DCA.●MAX / MIN, Difference, Peak Hold (SK-7718), and Range
Hold (SK-7719)●Dust-proof case is used to protect the tester from dust damage.
Functions
Continuity Test
Diode Test
Capacitance
Resistance
Accuracy±1.5%rdg±5dgt400 to 600A601 to 1000A±1.5%rdg±3dgt400 to 600A601 to 1000A±0.2%rdg±2dgt
±1.0%rdg±5dgt (40Hz to 400Hz)
±1.0%rdg±3dgt
±0.2%rdg±2dgt
±2.0%rdg±2dgt±1.5%rdg±5dgt
±1.0%rdg±3dgt
±4.0%rdg±5dgt±6.0%rdg±5dgt
±5.0%rdg±5dgt
±1.5%rdg±5dgt±3.0%rdg±5dgt
±1.5%rdg±3dgt±3.0%rdg±3dgt
Range400A
1000A
400A
1000A
1Hz to 1kHz4V40V400V600V400mV4V40V400V600V1Hz to49.99kHz10% to 90%400Ω4kΩ40kΩ400kΩ4MΩ40MΩ400Ω (Buzzer Sound : Approx. 50Ω or less)0 to 1.5VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF(±5.0%rdg±10dgt)Peak Hold (SK-7718), MAX / MIN, Difference,Power-on Initialize (for DC Current measurement),Range Hold (SK-7719), Display Hold,Auto Power OFF
A / A Hz
V / V Hz・% DC
Voltage
ACVoltage
DCCurrent
ACCurrent
Frequency
Frequency
Duty Cycle
SPECIFICATIONSDisplay
Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:
::::::::
4000 count LCD, Maximum reading 99993 times / secAuto Rangingφ35mm Max. 9V 6F22 Battery (x 1)CATⅢ 600V and EMC193(H) x 60(W) x 34.5(D) mm300g 100-57 Test Leads (x 1 set)1012 Carrying Case (x 1)9V 6F22 Battery (x 1)
OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips
948 Alligator Clips793 Coil-Type Contact Pin
DustProof
Simple WaterResistant
SK-7718
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
21
RNGHOLD
MAXM I N
PEAKHOLD
Powerful for Every Measurement
AC/DC
VAC/DC
2000ADISPHOLDDIFF
DUTY
%HzΩ
SK-7708FEATURES● "Power-On Initialize" (auto zero adjustment) for DCA.●Peak Hold, MAX / MIN measurements.●Dust-proof case is used to protect the tester from dust damage.
TRUERMSAPS
A / A Hz
V / V Hz・%
Range
400A
2000A
400A2000A1Hz to 4.999kHz
4V / 40V / 400V / 600V400mV / 4V / 40V / 400V / 600V1Hz to 100kHz0.1% to 99.9%400Ω4kΩ / 40kΩ / 400kΩ4MΩ40MΩ400ΩBuzzer Sound : Approx. 50Ω or less0 to 1.5VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μFMAX / MIN, Peak Hold, Difference, Power-on Initialize (for DC Current measurement), Range Hold, Display Hold, Auto Power Save
Accuracy
0 to 1000A1001A or more
±1.5%rdg±5dgt
±0.2%rdg±2dgt40Hz to 400Hz±1.5%rdg±5dgt ±1.2%rdg±3dgt ±0.2%rdg±2dgt±2.0%rdg±2dgt±1.5%rdg±5dgt±1.0%rdg±3dgt±3.0%rdg±4dgt±5.0%rdg±7dgt±1.5%rdg±5dgt
±5.0%rdg±5dgt
±5.0%rdg±10dgt
401Hz to 1KHz±3.0%rdg±5dgt
50Hz to 60Hz±1.5%rdg±5dgt ±1.5%rdg±5dgt ±3.0%rdg±5dgt
40Hz to 1kHz±3.0%rdg±5dgt ±3.0%rdg±5dgt
for DC Currentmeasurement
AUTOZERO
φ55mm
ConductorDiameter
Resistance
Functions
DC Voltage
ACVoltage
DCCurrent
ACCurrent
FrequencyDuty Cycle
Frequency
AC / DC Digital Clamp Meters
DustProof
SPECIFICATIONSDisplay
Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:
::::::::
4000 count LCD, Maximum reading 51203 times / secAuto / Manual Rangingφ55mm Max. 9V 6F22 Battery (x 1)CATⅢ 600V and EMC250(H) x 92(W) x 39(D) mm500g 100-57 Test Leads (x 1 set)1007 Carrying Case (x 1)9V 6F22 Battery (x 1)
OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin
Simple WaterResistant
Continuity Test
Diode Test
Capacitance
Pocket-sized Clamp Meter
AC
300A APODISPHOLD
FEATURES●Simple operation.●Strong and beaked Clamp Head against twists.●AUTO POWER OFF : turns off automatically after
12 minutes. ● Full Auto Ranging up to 300A AC.●DISPLAY HOLD Function.●With Carrying Case.
Accuracy
±1.8%rdg±5dgt
Range40A300A
Display Hold, Auto Power OFF
φ27mm
ConductorDiameter
ACCurrent
Functions
AC Digital Clamp Meters
SPECIFICATIONSDisplay
Sampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:
::::::::
4000 count LCD, Maximum reading 40002.5 times / secAuto Rangingφ27mm Max. 3V CR2032 Battery (x 1)CATⅢ 300V and EMC 150(H) x 52(W) x 24(D)mm 110g1004 Carrying Case (x 1)3V CR2032 Battery (x 1)
Clam
p Meters
Insulation Testers / Earth TesterD
igital M
ultim
etersA
nalo
g Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
22
AC Digital Clamp Meters
OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin
SK-7602
MAXM I N
Multi-functional Handy Clamp with Long Battery Life
AC/DC
VAC
400A
APODISPHOLDDIFF
DUTY
%HzΩ
FEATURES●290-hours long time measurement (SK-7603, with alkaline
cells) ● 13 measurement functions in one small package.●Rubber-molded rotary switch and trigger.●Easy-to-clamp compact & beaked clamp head even for
narrow conductors.● True RMS (SK-7660), MAX/MIN and Difference measurement.
Accuracy±1.5%rdg±5dgt (50Hz/60Hz)±3.0%rdg±5dgt (40Hz to 400Hz)±0.2%rdg±2dgt±1.0%rdg±3dgt
±1.0%rdg±2dgt
±1.5%rdg±5dgt (40Hz to 400Hz)
±0.2%rdg±2dgt
±2.0%rdg±3dgt±1.5%rdg±5dgt
±0.7%rdg±3dgt
±1.2%rdg±5dgt±3.0%rdg±5dgt
SK-7602
TRUERMS
A / Hz
V / VHz / %
Range40A400A5Hz to 1kHz400mV4V40V400V600V4V40V400V600V5Hz to49.99kHz5% to 95%400Ω4kΩ40kΩ400kΩ4MΩ40MΩ
Continuity Test, Diode Test, Capacitance
MAX / MIN, Difference, Display Hold,Auto Power OFF
OPTIONAL ACCESSORIES940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin
φ27mm
ConductorDiameter
SPECIFICATIONSDisplaySampling RateRange SelectionConductor DiameterPower SupplyCE Mark DimensionsWeightAccessories
:::::::::
4000 count LCD, Maximum reading 40503 times / secAuto Rangingφ27mm Max. 1.5V R03 or AAA Batteries (x 2)CATⅢ 300V, CATⅡ 600V and EMC 171(H) x 58(W) x 27(D)mm 140g100-63 Test Leads (x 1 set)1015 Carrying Case (x 1)1.5V R03 Batteries (x 2)
DCVoltage
ACVoltage
ACCurrent
Frequency
Frequency
Duty Cycle
Resistance
Functions
OtherMeasurements
Easy & Useful
Easy - to - ClampSK-7602 / 7603's compact and beaked clamp heads assure easy clamping even for narrow conductors.
Avoid YourFingers SlipsSK-7602 / 7603 are always fit on your hand. Double-Molding Rubbers on a Function Switch and a Trigger avoid your fingers slips during operation.
Test LeadHolderFixable Test Lead on the side of SK-7602 / 7603 by inserting its hook into the holder socket. Useful for Voltage, Resistance, Capacitance Measurements, Continuity and Diode Tests.
φ27mm MAX
High Quality Clamp Meter that contains DMM functions
AC/DC
VAC
400A
APODISPHOLD
Ω
FEATURES●Round Clamp Head opens two ways at slant position
assures accuracy and easy use.●Easy Operation with Rotary Switch.●Wide Measurement Ranges.
2A20A200A400A
Accuracy±5.0%rdg±10dgt±2.0%rdg±7dgt
±1.5%rdg±7dgt
Accuracy
±1.0%rdg±5dgt
±0.5%rdg±2dgt±0.8%rdg±2dgt±1.0%rdg±2dgt±1.5%rdg±5dgt±3.0%rdg±5dgt±5.0%rdg±5dgt
Range
2A/20A
200A/400A
Range
2V/20V/200V/600V
200mV2V/20V/200V600V200Ω/2kΩ/20kΩ/200kΩ2MΩ20MΩ
Continuity Test, Diode Test
Display Hold, Auto Power OFF
φ26mm
ConductorDiameter
SPECIFICATIONSDisplaySampling RateRange SelectionConductor DiameterPower SupplyDimensionsWeightAccessories
::::::::
2000 count LCD, Maximum reading 19993 times / secAuto Ranging(two-ranges auto for ACA)φ26mm Max. 1.5V LR-44 Batteries (x 2) 171(H) x 72(W) x 35(D) mm180g 100-57 Test Leads (x 1 set)983 Carrying Case (x 1)1.5V LR-44 Batteries (x 2)
DCVoltage
ACVoltage
ACCurrent
Resistance
Functions
OtherMeasurements
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
23
Advantages of SK-7820 / 7825
FEATURES●Wide range from 40mA to 100A AC.●Vibration and buzzer comparator convenient in noisy
surroundings. ● Low pass filter (cutoff 150Hz or more)● 100-hours continuous measurement (with alkaline cells)●Rubber-molded rotaty switch and trigger neatly fit in
your hand.
OPTIONAL ACCESSORIES940 Alligator Clips948 Alligator Clips
793 Coil-Type Contact Pin
SPECIFICATIONSDisplaySampling RateRange SelectionConductor DiameterPower SupplyCE Mark Dimensions
WeightAccessories
:::::::
::
4000 count LCD, Maximum reading 40502 times / sec Auto Ranging (mA / A : switch selection)SK-7820:φ24mm Max., SK-7825:φ40mm Max.1.5V (L) R03 or AAA Batteries (x 2) CATⅢ 300V, CATⅡ 600V and EMCSK-7820:168(H) x 58(W) x 27(D) mmSK-7825:184(H) x 58(W) x 27(D) mmSK-7820:170g, SK-7825:180g 100-63 Test Leads (x 1 set)1020 Carrying Case (x 1), 1.5V LR03 Batteries (x 2)
SK-7825
The World's First Vibration Alert Comparator Installed
AC
VAPODISP
HOLD
SK-7820/SK-7825
LPFCOMP
ACCurrent
Functions
ACVoltage
Accuracy (50/60Hz)0.10mA to 1.00mA1.01mA or more0.10A to 1.00A1.01A or more40.1A to 80.0A80.1A to 100.0A5.0V to 10.0V10.1V or more
Filter ON (50/60Hz)
add ±1.0%rdg±3dgt
add ±1.0%rdg±3dgt
Frequency Characteristic (40 to 400Hz)
add ±1.0%rdg±3dgt
add ±1.0%rdg±3dgt
±1.0%rdg±7dgt±1.0%rdg±5dgt±2.0%rdg±7dgt±2.0%rdg±5dgt±2.0%rdg±5dgt±4.0%rdg±5dgt ±2.0%rdg±7dgt±2.0%rdg±5dgt
Range
40mA / 400mA
40A
100A
400V / 600V
Vibration alert comparator, Low pass filter, Display Hold, Auto Power OFF
AC
100A
φ40mm
ConductorDiameter
SK-7825
φ24mm
ConductorDiameter
SK-7820
Vibration Alert ComparatorSK-7820 / 7825 incorporate Comparator Function in ~mA range. Buzzer sounds and vibrates if measuring value exceeds the setting value. Even in noisy surroundings, that can drown out the buzzer sound, vibration helps your comparator measurement. (Vibration alert is cancelable.)
Two-types-of Clamp HeadSK-7820's small clamp head assures easy clamping even for narrow conductors. SK-7825's large clamp head is suitable for thick conductors' measurement like 3-phase 3-wire system.
SK-7820
φ24mm Max φ40mm Max
SK-7820 SK-7825
AC Digital Clamp Meters
High Quality Clamp Meter that contains DMM functions
AC/DC
VAC
600A
APODISPHOLD
Ω
2A20A200A600A
Accuracy±5.0%rdg±10dgt ±2.0%rdg±7dgt
±1.5%rdg±7dgt
Accuracy
±1.0%rdg±5dgt
±0.5%rdg±2dgt±0.8%rdg±2dgt±1.0%rdg±2dgt±1.5%rdg±5dgt±3.0%rdg±5dgt±5.0%rdg±5dgt
Range
2A/20A
200A/600A
Range
2V/20V/200V/600V
200mV2V/20V/200V600V200Ω/2kΩ/20kΩ/200kΩ2MΩ20MΩ
Continuity Test, Diode Test
Display Hold, Auto Power OFF
φ42mm
ConductorDiameter
FEATURES●Round Clamp Head opens two ways at slant position
assures accuracy and easy use.●Easy Operation with Rotary Switch.●Wide Measurement Ranges.
SPECIFICATIONSDisplaySampling RateRange SelectionConductor DiameterPower SupplyDimensionsWeightAccessories
::::::::
2000 count LCD, Maximum reading 19993 times / secAuto Ranging (two-ranges auto for ACA)φ42mm Max. 1.5V LR-44 Batteries (x 2) 183(H) x 78(W) x 35(D) mm210g 100-57 Test Leads (x 1 set)983 Carrying Case (x 1)1.5V LR-44 Batteries (x 2)
DCVoltage
ACVoltage
ACCurrent
Resistance
OtherMeasurementsFunctions
OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin
AC Leakage Clamp Meters
Clam
p Meters
Insulation Testers / Earth TesterD
igital M
ultim
etersA
nalo
g Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
24
Insulation Testers Index
Model
Digital / Analog
Measurement Ranges
Insulation Resistance
Low Resistance
DC Voltage
AC Voltage
Continuity Test
Comparator
Data Memory
Timer
Live wire warning
Safety lock
High voltage warning
Automatic discharge
Display hold
Zero-ohm adjustment
Auto power save
Digital
4-Ranges
50V
125V
250V
500V
●●●-●●●●●●●●●●
SK-3500
Digital
4-Ranges
125V
250V
500V
1000V
●●●-●●●●●●●●●●
SK-3502
Analog
2-Ranges
250V
500V
----●---●-------
SK-3002
Analog
2-Ranges
500V
1000V
----●---●-------
SK-3003
Multi-Functional Insulation Testers
SK-3002/SK-3003/SK-3005
AC
V250V
50MΩ
SK-3002
500V100MΩ
SK-3002 / 3005
500V1000MΩ
SK-3003
1000V2000MΩ
SK-3003 / 3005
250V 500V 500V 1000VSK-3002 SK-3003
50MΩ0.05 to 50MΩ
1MΩ
100MΩ0.1 to 100MΩ
2MΩ
1000MΩ1 to 1000MΩ
20MΩ
2000MΩ2 to 2000MΩ
50MΩ
500V 1000VSK-3005
100MΩ0.1 to 100MΩ
2MΩ
2000MΩ1 to 2000MΩ
40MΩInfinite Scale : ±10% of Rated Voltage Center Scale : Over 90% of Rated Voltage
First effective range : ±5% of reading valueSecond effective range : ±10% of reading value
Zero and Infinite : ±0.7% of scale length0 to 600V
±3% of full scale valueApprox. 3 minutes
by Battery Scale on BATT. CHECK position
Rated Test Voltage (DC)Max. Effective ReadingEffective rangeCenter ScaleTerminal VoltageAccuracy
RangeAccuracy
Load
Power SourceL side E side
OFF
How to measure Volume Resistance Insulation Resistance Measurements
SK-3003
Analog Insulation Testers
SPECIFICATIONSPower SupplyDimensionsWeightAccessories
::::
1.5V R6P or AA Batteries (x 8)165(H) x 100(W) x 45(D) mm540g100-34 Test Leads (x 1 set), 939 Test Pin (x 1)978 Carrying Case (x 1), 1.5V R6P Batteries (x 8)
InsulationResistance
ACVoltage
TimerBattery Check
CoreConductor
Insulator
LeadCoating
Before measurement, make sure that the line (circuit) or object under test is not live.
OPTIONAL ACCESSORIES940R Red Alligator Clip
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
25
SK-3502
50V 125V 250V 500V 125V 250V 500V 1000V
Compact, But Powerfull. Versatile 4-Range Insulation Tester
SK-3500/SK-3502FEATURES●Wide Range of Insulation Measurement with Enhanced Safety.●Comparator Function.●Data Memory Function. (up to 100 data)
AC/DC
VDISPHOLD
DATAMEMO APSCOMP
50V200MΩ
SK-3500
125V200MΩ
250V2000MΩ
500V2000MΩ
1000V2000MΩ
SK-3502
ΩLOW
SK-3500 SK-3502
200MΩ5MΩ
0.200 to 10 MΩ
0 to 0.199 MΩ, 10.01 to 200.0 MΩ
2000MΩ50MΩ
0.200 to 100 MΩ
0 to 0.199 MΩ100.1 to 2000 MΩ
200MΩ5MΩ
0.200 to 10 MΩ
0 to 0.199 MΩ, 10.01 to 200.0 MΩ
2000MΩ50MΩ
0.200 to 100 MΩ
0 to 0.199 MΩ, 100.1 to 2000 MΩ
±3%rdg±4dgt
±5%rdg±5dgt
±3%rdg±4dgt
±5%rdg±5dgt
Comparator, Data memory, Timer, Live wire warning, Safety lock, High voltage warning, Automatic discharge, Zero-ohm adjustment, Backlight, Display hold, Auto power save
Common to SK-3500 / SK-350220.00Ω
200mA or more
DCV / ACV fixed (0V to 600V)
±3%rdg±5dgt
6V or more
±3%rdg±5dgtApprox. 660kΩ
400.0Ω
Approx. 10mA
AUTO (10V to 600V)
Digital Insulation Testers
SPECIFICATIONSDisplaySampling RatePower SupplyFuseCE MarkDimensionsWeightAccessories
::::::::
4000 count LCD, Maximum reading 40002 times / sec 1.5V R6P or AA Batteries (x 8)F22 (0.5A / 600V) x 1CATⅣ 600V CLASSⅡand EMC120(H) x 130(W) x 70(D) mm600g100-61 Test Leads (x 1 set), 945B Black Alligator Clip (x 1)1016 Carrying Case (x 1), 1.5V RW6P Batteries (x 8)Spare Fuse F22 (0.5A / 600V) x 1 (built-in)
SimpleDust Proof
SimpleWater Resistant
OPTIONAL ACCESSORIES766B Black Test Prod (with 767B Black Test Pin)940R Red Alligator Clip948R Red Alligator Clip
Rated Test Voltage (DC)Max. Effective ReadingCenter Reading1st effective rangeAccuracy2nd effective range
Accuracy
Display Range (Auto-ranging)Accuracy (After 0Ω Adjustment)Measurement CurrentOpen Circuit VoltageRangeAccuracyInput Resistance
InsulationResistance
LowResistance
AC / DCVoltage
Functions
Advantages of SK-3500 / 3502
Wide Digital DisplayBargraph LCD (with backlight)Wide bargraph scale that can confirm measurement values on sight like an analog meter. Backlight is helpful for easy reading even in dark areas.
Data Memory FunctionUp to 100 data can be saved in internal memory together with their measured date and time. (for Insulation Resistance and Low Resistance)
Comparator FunctionBuzzer sounds and "HIGH" or "LOW" light up if measuring value exceeds or falls below the threshold. (for Insulation Resistance and Low Resistance)
Example) Memorize 100MΩ measured under 1000V.
Selectable by SELECT Key
MeasuredTime
MeasuredDate
MeasuredYear
Example) When setting a buzzer on 10MΩ or lower.
Set a buzzer on10MΩ or lower.
Measure 4MΩ
Measure 40MΩ
V
flashesand buzzer sounds.
lights up
26
Digital Multimeters Index
Model
Display Counts
Bargraph
DC Voltage
AC Voltage
DC Current
AC Current
Resistance
Frequency
Duty Cycle
Continuity Test
Diode Test
Capacitance
Temperature
True RMS
Auto Ranging
Manual Ranging
MAX / MIN
Range Hold
Difference
Display Hold
Comparator
Current by Clamp Adapter
Dust Proof & Simple Water Resistant
Backlight
Penlight
Auto Power Save (Off)
4000
-
400mV
4V
40V
400V
1000V
-
4V
40V
400V
750V
-
-
40mA
400mA
4A
20A
-
-
40mA
400mA
4A
20A
-
-
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
●
●
●
●
-
-
-
●
●
-
●
-
-
-
●-
-
-
●
4000
-
400mV
4V
40V
400V
1000V
-
4V
40V
400V
750V
-
-
400μA
4000μA
40mA
400mA
4A
20A
400μA
4000μA
40mA
400mA
4A
20A
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
●
●
●
●
●
-
-
●
●
-
●
●
●
-
●-
-
-
●
4000
-
400mV
4V
40V
400V
600V
-
400mV
4V
40V
400V
600V
-
400μA
4000μA
40mA
400mA
4A
10A
400μA
4000μA
40mA
400mA
4A
10A
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
●
●
●
●
●
●
-
●
●
-
●
●
●
-
●
-
-
-
●
4000
-
400mV
4V
40V
400V
600V
-
400mV
4V
40V
400V
600V
-
40mA
400mA
10A
-
-
-
40mA
400mA
10A
-
-
-
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
●
●
●
●
●
-
-
●
●
-
●
●
●
-
●
-
-
-
●
Clam
p Meters
Insulation Testers / Earth TesterD
igital M
ultim
etersA
nalo
g Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
27
Digital Multimeters Index
Model
Display Counts
Bargraph
DC Voltage
AC Voltage
DC Current
AC Current
Resistance
Frequency
Duty Cycle
Continuity Test
Diode Test
Capacitance
Temperature
True RMS
Auto Ranging
Manual Ranging
MAX / MIN
Range Hold
Difference
Display Hold
Comparator
Current by Clamp Adapter
Dust Proof & Simple Water Resistant
Backlight
Penlight
Auto Power Save (Off)
4000
-400mV
4V
40V
400V
600V
-4V
40V
400V
600V
--
40mA
400mA
----
40mA
400mA
----
400Ω4kΩ
40kΩ400kΩ4MΩ
40MΩ●●●●●--●-●-●●---●●●
4000
●400mV
4V
40V
400V
1000V
-400mV
4V
40V
400V
750V
-40mA
400mA
4A
20A
--
40mA
400mA
4A
20A
--
400Ω4kΩ
40kΩ400kΩ4MΩ
40MΩ●-●●---●●●●●●-●●--●
4000
-
400mV
4V
40V
400V
600V
-
400mV
4V
40V
400V
600V
-
400μA
4000μA
40mA
400mA
10A
-
400μA
4000μA
40mA
400mA
10A
-
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
-
-
-
-
-
-
-
●
●
-
●
-
-
●
●
-
-
-
-
SK-4033SK-6597
4000
-400mV
4.0V
40V
400V
600V
-4.0V
40V
400V
600V
-------
-----
400Ω4.0kΩ40kΩ
400kΩ4.0MΩ40MΩ●●●●●--●-●-●●-----●
4000
-
400mV
4V
40V
400V
600V
-
400mV
4V
40V
400V
600V
-
400μA
4000μA
40mA
400mA
10A
-
400μA
4000μA
40mA
400mA
10A
-
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
-
-
-
-
-
-
●
●
●
-
●
-
-
●
●
-
-
-
-
SK-4035
Clam
p Meters
Insulation Testers / Earth TesterD
igital M
ultim
etersA
nalo
g Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
28
Digital Multimeters Index
Model
Display Counts
Bargraph
DC Voltage
AC Voltage
DC Current
AC Current
Resistance
Frequency
Duty Cycle
Continuity Test
Diode Test
Capacitance
Temperature
True RMS
Auto Ranging
Manual Ranging
MAX / MIN
Range Hold
Difference
Display Hold
Comparator
Current by Clamp Adapter
Dust Proof & Simple Water Resistant
Backlight
Penlight
Auto Power Save (Off)
4000
-400mV
4.0V
40V
400V
600V
-4.0V
40V
400V
600V
-------
-----
400Ω4.0kΩ40kΩ
400kΩ4.0MΩ40MΩ●●●●●--●●●●●●-----●
2000
-200mV
2V
20V
200V
600V
-2V
20V
200V
600V
-------
-----
200Ω2kΩ20kΩ
200kΩ2MΩ20MΩ--●●---●----●-----●
4000
-400mV
4V
40V
400V
500V
-400mV
4V
40V
400V
500V
------
-----
400Ω4kΩ40kΩ
400kΩ4MΩ40MΩ--●●---●----------●
KU-1199
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
Digital Multimeters (Handy Type)
High Cost Performance, Temperature Measurement (KU-2602)
AC/DC
VAC/DC
AAPODISP
HOLDRNGHOLDDIFF
DUTY
%HzΩ
FEATURES● Temperature Measurement. (Temperature Probe is provided) (KU-2602)● Tilt Stand and Test Lead Holder on rear side.●Display Hold, Range Hold functions.●Auto Power Off, Reset functions.
OPTIONAL ACCESSORIES660 AC / DC Clamp Adapter817-03 to 817-25 Temperature Probes (KU-2602)100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin995 Carrying Case
SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyFuse
CE MarkDimensions WeightAccessories
:::::
::::
4000 count LCD2 times / secAuto / Manual Ranging1.5V R6P or AA Batteries (x 2)F14 (0.5A / 250V) x 1F17 (10A / 250V) x 1CATⅡ600V, CATⅢ 300V compliant155(H) x 75(W) x 29(D) mm 180gHolster, 100-50 Test Leads (x 1 set)818-02 Temperature Probe (x 1)(KU-2602)1.5V R6P Batteries (x2 & spare)Spare Fuses F14 (0.5A/250V) & F17 (10A/250V) x 1 each
DCVoltage
ACVoltage
DCCurrent
ACCurrent
Resistance
Temperature
Functions
KU-2600/KU-2602
Input Impedance≧100MΩ
≒10MΩ
≒10MΩ
Voltage Drop200mV2.2V MAX200mV200mV2.2V MAX200mV
KU-2600
KU-2602
KU-2602
DCVoltage
ACVoltage
DCCurrent
ACCurrent
Resistance
Frequency
Continuity Test
Duty Cycle
Diode Test
Capacitance
Frequency
Continuity Test
Duty Cycle
Diode Test
Capacitance
Functions
Standard hand-heldDigital MultimeterEasy to carry around to any measuring field.
Color-codedRange SwitchHelps your range selecting with color-coding switches.
Example:Press SELECT key (colored yellow) to select AC or DC in mA or A measuring ranges.
Test-Lead-FixableRubber HolsterNo need to f ind the place to set the Digital Multimeter in measuring field.KU-2600/2602 al lows quick measurement holding the unit in hand.
29
Features of KU-2600/KU-2602
Range400mV4V/40V400V/600V400mV4V/40V400V600VRange40mA400mA10A40mA400mA10A400Ω/4kΩ40kΩ/400kΩ4MΩ/40MΩOpen Circuit Voltage : Approx. 0.44V9.999Hz to9.999MHz0% to99.9%
400Ω (Buzzer Sound : Approx. 50Ω or less)
4VOpen Circuit Voltage : ≦1.5V0.1nF to 40nF / 40nF to 40μF / 40μF to 200μF (±3.0%rdg±5dgt)Difference, Range Hold, Display Hold, Auto Power Off, Reset
Resolution100μV1mV/10mV100mV/1V0.1mV1mV/10mV100mV1VResolution10μA100μA10mA10μA100μA10mA0.1Ω/1Ω10Ω/100Ω1kΩ/10kΩ
0.01Hz to1.0kHz
0.1%
Accuracy
±0.5%rdg±4dgt
±1.0%rdg±4dgt±4.0%rdg±8dgt
±1.2%rdg±5dgt
±1.5%rdg±5dgtAccuracy
±2.0%rdg±4dgt
±2.5%rdg±4dgt±2.5%rdg±5dgt
±3.0%rdg±5dgt
±1.0%rdg±3dgt
±1.8%rdg±3dgt
±0.2%rdg±1dgt
±0.2%rdg±2dgt
±5.0%rdg±3dgt
Range400mV4V40V400V600V400mV4V40V400V600VRange400μA/4000μA40mA/400mA4A/10A400μA/4000μA40mA/400mA4A/10ARange400Ω4kΩ40kΩ400kΩ4MΩ40MΩOpen Circuit Voltage : Approx. 0.44VRange0℃ to 40℃-20℃ to 200℃200℃ to 500℃9.999Hz to9.999MHz0.1% to99.9%
400Ω (Buzzer Sound : Approx. 60Ω or less)
4VOpen Circuit Voltage : ≦1.5V4 / 40 / 400nF / 4 / 40 / 200μF (±2.0%rdg±5dgt)Difference, Range Hold, Display Hold, Auto Power Off, Reset
Resolution0.1mV1mV10mV100mV1V0.1mV1mV10mV100mV1VResolution0.1μA/1μA10μA/100μA1mA/10mA0.1μA/1μA10μA/100μA1mA/10mAResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Resolution
1℃
0.01Hz to1.0kHz
0.1%
Accuracy
±0.5%rdg±5dgt
±0.8%rdg±5dgt±1.2%rdg±5dgt
±0.8%rdg±5dgt
±1.2%rdg±5dgtAccuracy
±1.5%rdg±5dgt
±2.0%rdg±5dgt
±2.0%rdg±5dgt
±2.5%rdg±5dgtAccuracy
±1.0%rdg±5dgt
±2.0%rdg±5dgt
Accuracy±3℃±0.75%rdg±3℃±1.5%rdg±3℃
±0.02%rdg±5dgt
±2%rdg±5dgt
±5.0%rdg±3dgt
Input Impedance>100MΩ≒11MΩ
≒10MΩ
≒11MΩ
≒10MΩ
Voltage Drop40mV/400mV70mV/700mV500mV/1.4V40mV/400mV70mV/700mV500mV/1.4VTest Current≦0.3mA≦40μA≦4μA≦0.4μA
≦40nA
SensorBuilt-in
External
Clam
p Meters
Insulation Testers / Earth TesterD
igital M
ultim
etersA
nalo
g Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
Frequency
Digital Multimeters (Handy Type)
DCVoltage
ACVoltage
DCCurrent
Frequency
ACCurrent
Resistance
Functions
Range400mV4V40V400V1000V400mV4V40V400V750VRange40mA /400mA
4A / 20A
40mA /400mA
4A / 20A
Range400Ω4kΩ40kΩ400kΩ4MΩ40MΩOpen Circuit Voltage : ≦0.4V99.99Hz to999.9kHz400Ω (Buzzer Sound : Approx. 40Ω or less)2VOpen Circuit Voltage : ≦3.3VMAX / MIN, Difference, Range Hold, Display Hold, Auto Power Save
Resolution100μV1mV10mV100mV1V100μV1mV10mV100mV1VResolution
100μA
10mA
100μA
10mA
Resolution100mΩ1Ω10Ω100Ω1kΩ10kΩ
0.01Hz to100Hz
1mV
Accuracy
±0.5%rdg±2dgt
±0.8%rdg±1dgt
±2.0%rdg±7dgt
±1.5%rdg±5dgt
Accuracy
±1.2%rdg±2dgt
0 to 10.00A±2.0%rdg±2dgt10.01 to 20A ±2.5%rdg±4dgt
±2.5%rdg±5dgt
0 to 10.00A±2.5%rdg±5dgt10.01 to 20A±3.0%rdg±10dgtAccuracy±1.0%rdg±2dgt
±0.7%rdg±2dgt
±1.0%rdg±2dgt±2.0%rdg±2dgt
±0.3%rdg±3dgt(999.9Hz / 9.999kHz Range)
Input Impedance≧100MΩ≒11MΩ
≒10MΩ
≧100MΩ≒11MΩ
≒10MΩ
Voltage Drop40mV(40mA)400mV(400mA)
130mV(4A)350mV(10A)
40mV(40mA)400mV(400mA)
130mV(4A)350mV(10A)
Test Current≦0.5mA≦0.2mA≦40μA≦4μA≦0.4μA≦40nA
4000 Count DMM with Bargraph
AC/DC
VAC/DC
ARNGHOLD
ΩFEATURES● Large LCD with Bargraph.●Tough designed case with Dust-proof and
Water-resistant structure.
SPECIFICATIONSDisplay
Sampling Rate
Range SelectionPower SupplyFuseCE MarkDimensions WeightAccessories
:
:
:::::::
(Numerical) 4000 count LCD,Maximum Reading 9999(Bargraph) 40 segments(1 segment / 100 digits)(Numerical) 3 times / sec(Bargraph) 30 times / secAuto / Manual Ranging1.5V R6P or AA Batteries (x 2)F33 (15A / 1000V) x 1, F34 (2A / 1000V) x 1CAT Ⅱ 600V and EMC180(H) x 86(W) x 35(D) mm 320g100-57 Test Leads (x 1 set)1.5V R6P Batteries (x 2)
DISPHOLD
OPTIONAL ACCESSORIES660 AC / DC Clamp Adapter100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips
948 Alligator Clips793 Coil-Type Contact Pin995 Carrying Case
BARGRAPH
APSMAXM I N DIFF
Hz
DustProof
Simple WaterResistant
30
SK-6161
::
:::
:::
SPECIFICATIONSDisplaySampling Rate
Range SelectionPower SupplyFuse
Dimensions WeightAccessories
4000 count LCD 2.5 times / sec(except frequency duty cycle, capacitance measurements)Auto / Manual Ranging1.5V R6P or AA Batteries (x 2)F14 (0.5A / 250V) x 1 F16 (15A / 250V) x 1160(H) x 75(W) x 34(D) mm, 180g100-57 Test Leads (x 1 set)1020 Carrying Case1.5V R6P Batteries (x 2)Spare Fuses F14 (0.5A / 250V) &F16 (15A / 250V) x 1 each
Advantages of SK-6161/ 6163
Easy-to-readlarge LCD
Colored range switchfor easy operation
Range400mV4V40/400/1000V4V40/400/750V5Hz to 20kHz10 to 90%Range400μ/4000μA*40m/400mA4A
20A
400μ/4000μA*40m/400mA4A
20A
5Hz to 1kHzRange400Ω4kΩ40kΩ400kΩ4MΩ40MΩOpen Circuit Voltage : Approx. 0.44V
400Ω (Buzzer Sound : Approx. 60Ω or less)
1VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF (±5.0%rdg±10dgt)Difference (SK-6163), Range Hold, Display Hold (SK-6163), Auto Power Save
Resolution0.1mV1mV10m/100m/1V1mV10m/100m/1V0.01 to 10Hz0.1%Resolution0.1μ/1μA0.01m/0.1mA1mA
10mA
0.1μ/1μA0.01m/0.1mA1mA
10mA
0.01 to 1HzResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Accuracy±0.5%rdg±2dgt
±0.5%rdg±1dgt
±1%rdg±5dgt
±0.2%rdg±2dgt±2%rdg±2dgtAccuracy±1%rdg±1dgt±1%rdg±1dgt±1.5%rdg±2dgt0~10.00A ±1.5%rdg±2dgt10.01~20.00A ±2.5%rdg±4dgt±1.5%rdg±5dgt±1.5%rdg±5dgt±2%rdg±7dgt0~10.00A ±2%rdg±7dgt10.01~20.00A ±3%rdg±7dgt±0.2%rdg±2dgtAccuracy±0.8%rdg±3dgt
±0.8%rdg±2dgt
±2%rdg±3dgt±3%rdg±3dgt
±5.0%rdg±3dgt
Input Impedance>100MΩ≒11MΩ≒10MΩ≒11MΩ≒10MΩ
Voltage Drop0.11mV/μA2mV/mA30mV/A
30mV/A
0.11mV/μA2mV/mA30mV/A
30mV/A
Test Current≦0.3mA≦40μA≦4μA≦0.4μA
≦40nA
Easy-to-read Large LCD with 20mm high numerals
AC/DC
VAC/DC
A Ω
FEATURES●Easy-to-read Large LCD with 20mm high numerals.● 300 hours continuous operation with only two 1.5V Batteries.● 20A AC / DC Measurements.
SK-6163SK-6163 SK-6163
* 400μA / 4000μA range is SK-6163 only.
SK-6163
APSDISPHOLD
RNGHOLDDIFF
DUTY
%Hz
940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin
OPTIONAL ACCESSORIES660 AC / DC Clamp Adapter100-41 Test Lead Kit100-62 Test Lead Set
DCVoltage
ACVoltage
DCCurrent
ACCurrent
Functions
Resistance
Frequency
Continuity Test
Duty Cycle
Diode Test
Capacitance
Continuity Test
Diode Test
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
Resolution100μV1mV10mV100mV/1V1mV10mV/100mV1V0.001 to 100Hz0.1%Resolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Input Impedance≧100MΩ≒11MΩ
≒10MΩ
≒11MΩ
≒10MΩ
Test Current≦0.2mA≦50μA≦5μA≦0.5μA
≦50nA
≦0.7mA
OPTIONAL ACCESSORIES940 Alligator Clips948 Alligator Clips
792R Red Straight Test Pin793 Coil-Type Contact Pin
FEATURES●Smart Design for Easy of Use.● Fully line-upped function for useful measurements.●MAX / MIN, and Difference Measurements are available.
DCVoltage
ACVoltage
Resistance
Functions
SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyCE MarkDimensions WeightAccessories
::::::::
4000 count LCD 3 times / sec.Auto Ranging3V CR2032 Battery (x 1)CATⅢ 600V and EMC 179(H) x 28(W) x 20(D) mm 60g100-52 Test Leads (x 1), 1006 Carrying Case (x 1)3V CR2032 Battery (x 1)
31
Multi-Functional and Versatile Probe Tester
AC/DC
VAPODISP
HOLDMAXM I N DIFF
DUTY
%HzΩ
FrequencyDuty Cycle
Continuity Test
Diode Test
Capacitance
Range400mV4.0V40V400V/600V4.0V40V/400V600V1Hz to 100kHz0 to 99.9%Range400Ω4.0kΩ40kΩ400kΩ4.0MΩ40MΩOpen Circuit Voltage : ≒0.44V
400Ω (Buzzer Sound : Approx. 60Ω or less)
1VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF (±5.0%rdg±10dgt)MAX / MIN, Difference, Display Hold, Auto Power Off
Accuracy
±0.5%rdg±3dgt
±1.0%rdg±3dgt
±1.5%rdg±5dgt
±0.2%rdg±2dgt±0.5%rdg±5dgtAccuracy±1.5%rdg±4dgt
±1.0%rdg±3dgt
±5.0%rdg±3dgt±7.0%rdg±3dgt
±5.0%rdg±3dgt
OPTIONAL ACCESSORIES940 Alligator Clips948 Alligator Clips792R Straight Test Pin (Red)793 Coil-Type Contact Pin1026 Carrying Case
FEATURES●Current measurement up to AC / DC 400mA.●Penlight and backlight LCD.
SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyFuseCE MarkDimensions WeightAccessories
4000 count LCD 3 times / sec.Auto Ranging1.5V LR44 Battery (x 2)F22 (0.5A / 600V) x 1CATⅢ 600V and EMC 209(H) x 38(W) x 32(D) mm Approx. 110g (include battery)100-68 Test Lead (Black) (x 1)1.5V LR44 Batteries (x 2)780 Red Insulation Cap (x 1) 781 Test Lead Insulation Cap (Black) (x 1)
:::::::::
Improved probe tester with enhanced functions
SK-6597
AC/DC
VAC/DC
AAPODISP
HOLD
HzΩ DUTY
%PEN
LIGHTMAXM I N DIFF
Digital Multimeters (Probe Tester)
Range400mV4V40V400V600V
4V40V400V600V1Hz to 100kHz0.0% to 99.9%Range40mA400mA40mA400mA10Hz to 100kHzRange400Ω4kΩ40kΩ400kΩ4MΩ40MΩOpen Circuit Voltage : ≒0.44V400Ω (Buzzer Sound : Approx. 50Ω or less)1VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF MAX / MIN, Display Hold, Difference, Auto Power Off,Penlight and Backlight
Resolution0.1mV1mV10mV100mV1V
1mV10mV100mV1V0.001 to 100Hz0.1%Resolution10μA100μA10μA100μA0.01 to 100HzResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Accuracy
50Hz to 500Hz
±1.5%rdg±5dgt
Accuracy
Accuracy
Input Impedance≧100MΩ≒11MΩ
≒10MΩ
≒11MΩ
≒10MΩ
Burden Voltage<0.1V<0.6V<0.1V<0.6V
Test Current≦0.2mA≦50μA≦5μA≦0.5μA
≦50nA
±0.5%rdg±3dgt
±1.0%rdg±3dgt
±1.0%rdg±2dgt
±1.5%rdg±7dgt
±0.2%rdg±2dgt
±0.2%rdg±2dgt±0.5%rdg±5dgt
±1.5%rdg±4dgt
±1.0%rdg±3dgt
±5.0%rdg±3dgt±7.0%rdg±3dgt
±5.0%rdg±3dgt
±5.0%rdg±10dgt
DCCurrent
AC Current40Hz to 500Hz
DCVoltage
ACVoltage
Resistance
Functions
Continuity Test
Capacitance
Diode Test
Frequency
Frequency
Duty Cycle
≦0.7mA
Advantages of SK-6597
Penlight andbacklight LCDBrightly i l luminate test points and display even in the dark place.
Current measurementCan measure up to 400mA AC/DC.
Easy-to-use pen-type testerHandheld tester like an industrial tool.
Easy-to-read large LCD (compared to the existing model)
Clear buzzer soundEasy-to-hear buzzer sound even in noisy conditions.
Easy-to-use large Test Lead
Gold-plated Test Pin and Test Lead Tip
Replaceable Test Pin and Test LeadEasy replacement without any tools.
・Screw-in type Test Pin ・Plug-in type Test Lead
Clam
p Meters
Insulation Testers / Earth TesterD
igital M
ultim
etersA
nalo
g Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
32
Digital Multimeters (All-in-one DMM)
Range400mV4.0V40V400V/600V4.0V40V/400V600V1Hz to 100kHz0 to 99.9%Range400Ω4.0kΩ40kΩ400kΩ4.0MΩ40MΩOpen Circuit Voltage : ≒0.44V
400Ω (Buzzer Sound : Approx. 60Ω or less)
1VOpen Circuit Voltage : ≦1.7V50 / 500nF / 5 / 50 / 100μF (±5.0%rdg±10dgt)MAX / MIN, Difference, Range Hold, Display Hold,Auto Power Save
Resolution100μV1mV10mV100mV/1V1mV10mV/100mV1V0.001 to 100Hz0.1%Resolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Accuracy
±0.5%rdg±3dgt
±1.0%rdg±3dgt
±1.5%rdg±5dgt
±0.2%rdg±2dgt±0.5%rdg±5dgtAccuracy±1.5%rdg±4dgt
±1.0%rdg±3dgt
±3.0%rdg±3dgt±7.0%rdg±3dgt
±5.0%rdg±3dgt
Input Impedance≧100MΩ≒11MΩ
≒10MΩ
≒11MΩ
≒10MΩ
Test Current≦0.2mA≦50μA≦5μA≦0.5μA
≦50nA
≦0.7mA
DCVoltage
ACVoltage
Resistance
Functions
OPTIONAL ACCESSORY940 Alligator Clips948 Alligator Clips
793 Coil-Type Contact Pin
SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyCE MarkDimensions WeightAccessories
::::::::
4000 count LCD 3 times / secAuto / Manual Ranging3V CR2032 Battery (x 1)CATⅢ 300V and EMC118(H) x 78(W) x 16(D) mm 110g3V CR2032 Battery (x 1)
High-Precision DMM
AC/DC
V
APSDISPHOLD
MAXM I N
RNGHOLDDIFF
DUTY
%HzΩ
FEATURES●Multi-functional Card Type DMM comparable to Large
Multi meter.●Very Useful for Any Measurement Conditions.
Output Terminals
SK-4035
Digital Multimeters (Bench-Top DMM)
OPTIONAL ACCESSORIES660 AC/DC Clamp Adapter100-41 Test Lead Kit100-62 Test Lead Set
940 Alligator Clip948 Alligator Clip793 Coil-Type Contact Pin
Bench-Type DMM with Output Terminals
FEATURES●Output terminals to connect and control the external
inspection equipments.●SK-4035 assures the accurate measurementby True RMS.●Comparator function useful for the quality check in the
production line.●Easy-to-use simple lay out keys Easy-to-read large display.
AC/DC
VAC/DC
ATRUERMS
RNGHOLDΩ COMP
Range400mV4V40/400/600V400mV4V40/400/600VRange400μA/4000μA40mA400mA10A400μA/4000μA40mA400mA10ARange400Ω4kΩ40kΩ400kΩ4MΩ40MΩComparator, Range Hold
Resolution0.1mV1mV10mV/100mV/1V0.1mV1mV10mV/100mV/1VResolution0.1μA/1μA10μA100μA10mA0.1μA/1μA10μA100μA10mAResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Accuracy
±0.3%rdg±2dgt
±1.0%rdg±5dgt(50Hz~500Hz)
Accuracy
±0.75%rdg±2dgt
±1.5%rdg±2dgt
±1.5%rdg±6dgt(50Hz~500Hz)
Accuracy±0.3%rdg±3dgt
±0.3%rdg±2dgt
±1%rdg±2dgt±3%rdg±4dgt
Input Impedance>100MΩ≒11MΩ≒10MΩ>100MΩ≒11MΩ≒10MΩVoltage Drop<0.05V / <0.25V<0.1V<0.6V<0.5V<0.05V / <0.25V<0.1V<0.6V<0.5VTest Current≦1.1mA≦110μA≦12.0μA≦1.2μA≦0.12μA≦0.12μA
SK-4033/SK-4035SK-4035
Open Circuit Voltage2.4V
1.2V
:::::
:::
SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyFuse
Dimensions WeightAccessories
4000 count LCD 10 times / secAuto / Manual RangingAC adapterF29 (3A/600V ) x 1, F30 (10A/600V ) x 1F31 (0.5A/250V) x 295(H) x 200(W) x 260(D) mm, 1,140g100-57 Test Leads (x 1 set), AC AdapterSpare Fuse F31 (0.5A / 250V) x 1
DCVoltage
ACVoltage
DCCurrent
ACCurrent
Resistance
Functions
SK-4033/4035
Waster
Suitable for theinspection automation
OutputTerminals
FrequencyDuty Cycle
Continuity Test
Diode Test
Capacitance
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
33
Range400mV4V40V400V500V400mV4V40V400V500VRange400Ω4kΩ40kΩ400kΩ4MΩ40MΩOpen Circuit Voltage : ≦0.25V
400Ω (Buzzer Sound : 12Ω to 70Ω)
2VOpen Circuit Voltage : ≦2.9VAuto Power Off
Resolution100μV1mV10mV100mV1V100μV1mV10mV100mV1VResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Accuracy
±0.5%rdg±3dgt
±0.8%rdg±3dgt±1.0%rdg±8dgt (100mV~)
±0.8%rdg±3dgt
±1.2%rdg±3dgtAccuracy±1.0%rdg±5dgt
±1.0%rdg±3dgt
±2.0%rdg±3dgt
±5.0%rdg±3dgt
Input Impedance
≒5MΩ
≒5MΩ
1±0.6mA
DCVoltage
ACVoltage
Resistance
Functions
OPTIONAL ACCESSORY940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin
FEATURES
●Auto-SCAN Measurement. No need for selecting
DC/AC Voltages and Resistance ranges.●Only 11mm thick and 72g in Weight.●Easy-to-read largeLCD.●Equipped with carrying case.●Gold-plated Test Lead Pins.
SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyCE MarkDimensions WeightAccessories
::::::::
4000 count LCD 3 times / secAuto Ranging1.5V LR44 Batteries (x 2)CATⅡ500V and EMC112(H) x 56(W) x 11(D) mm Approx. 72g1.5V LR44 Batteries (Installed) (x 2)1005 Carrying Case
Auto Measurement for DC / AC Voltage & Resistance
AC/DC
V APOΩ
Digital Multimeters (Card-Type DMM)
Continuity Test
Diode Test
Range200mV2V20V200V600V2V20V200V600VRange200Ω2kΩ20kΩ200kΩ2MΩ20MΩOpen Circuit Voltage : ≦0.45V
200Ω (Buzzer Sound : Approx. 50Ω or less)
2VOpen Circuit Voltage : ≦1.7VDisplay Hold, Auto Power Off
Resolution100μV1mV10mV100mV1V1mV10mV100mV1VResolution0.1Ω1Ω10Ω100Ω1kΩ10kΩ
Accuracy±1.3%rdg±5dgt
±1.3%rdg±3dgt
±2.0%rdg±8dgt
Accuracy
±2.0%rdg±4dgt
±5.0%rdg±4dgt
±5.0%rdg±4dgt
Input Impedance≧100MΩ≒12MΩ
≒10MΩ
≒12MΩ
≒10MΩ
Test Current≦1mA≦0.3mA≦40μA≦4μA≦0.4μA≦0.04μA
≦0.7mA
DCVoltage
ACVoltage
Resistance
Functions
OPTIONAL ACCESSORY940 Alligator Clips948 Alligator Clips793 Coil-Type Contact Pin
SPECIFICATIONSDisplaySampling RateRange SelectionPower SupplyCE MarkDimensions WeightAccessories
::::::::
2000 count LCD 3 times / secAuto Ranging3V CR2032 Battery (x 1)CATⅡ600V, CATⅢ 300V and EMC109(H) x 55(W) x 9(D) mm Approx. 60g3V CR2032 Battery (x 1)Notebook type Carrying Case
FEATURES●Compact & Light Weight.●Wide Measurement Ranges.●Gold-plated Test Lead Pins.● Large Rotary Switch.●Useful Functions.
Simple & Easy
AC/DC
V APODISPHOLDΩ
Advantages of SK-6500
Notebook typeCarrying CasePocketab le tes te r fo r easy to carry around.
UltraslimCard-type DMMObviously slim and light weight. Only 9mm thick and 60g weight.
Auto-SCAN Measurement
Continuity Test
Diode Test
DC VoltageExample : Battery
AC VoltageExample : Wall outlet
ResistanceExample : 5Ω resistor
KU-1199
Turn on the instrument with Rotary Switch. “SCAN” is displayed.Connect Black Test Prod to the - (earth) side of the circuit to be measured and Red Test Prod to the + (positive) side.The instrument automatically detects the items to be measured (DCV, ACV or Ω) and start the measurement. Read the test result on LCD.
1.
2.
3.
Clam
p Meters
Insulation Testers / Earth TesterD
igital M
ultim
etersA
nalo
g Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
34
Analog Multitesters
KF-20
Tough-designed Holster with Test Lead Holder
ΩDC
AAC/DC
V
Range
0.3 / 3 / 12 / 30 / 120 / 300 / 1200V
12 / 30 / 120 / 300 / 1200V
60μ/ 3m / 30m / 300mA
5k / 500k / 5MΩ
1.5V (R20P / R14P / R6P)1.5V 250mA (Hi Range)1.5V 50mA (Low Range)
InternalResistance
20kΩ/V
10kΩ/V
Tolerance
±3% f.s.
±4% f.s.
±3% f.s.
±3% f.s. length
948 Alligator Clips793 Coil-Type Contact Pin
SPECIFICATIONSPower SupplyFuseDimensions WeightAccessories
:::::
1.5V R6P or AA Battery (x 1)F12 (0.3A / 250V) x 1136(H) x 90(W) x 30(D) mm 215gHolster100-51 Test Leads (x 1 set)1.5V R6P Battery (built-in & spare) x 1 eachSpare Fuse F12 (0.3A / 250V) x 1
OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips
948 Alligator Clips793 Coil-Type Contact Pin
SPECIFICATIONSPower SupplyFuseDimensions WeightAccessories
:::::
1.5V R6P or AA Battery (x 1)F15 (0.75A / 250V) x 1136(H) x 90(W) x 30(D) mm 215g100-64 Test Leads (x 1 set)1020 Carrying Case, 1.5V R6P Battery (x 1)Spare Fuse F15 (0.75A / 250V) x 1 (built-in)
DC 12A measurement
DCVoltage
ACVoltage
DCCurrent
Resistance
BatteryTest
BATT.TEST
Range
0.3 / 3 / 12 / 30 / 120 / 300 / 1200V
12 / 30 / 120 / 300 / 1200V
60μ / 3m / 30m / 600m / 12A
5k / 500k / 5MΩ(×1 / ×100 / ×1k)
Buzzer sounds less than approx. 30Ω
InternalResistance
20kΩ/V10kΩ/V
Tolerance
±3% f.s.
±4% f.s.
±3% f.s.
±3% f.s. length
KF-32FEATURES●DC 12A measurement.
AC/DC
V ΩDC
A
OPTIONAL ACCESSORIES100-41 Test Lead Kit100-62 Test Lead Set940 Alligator Clips
*Continuous measurement in 12A DC range is restricted up to 1 minute. More than 1 minute interval is necessary for the next measurement.
DC Voltage
AC Voltage
DC Current
Resistance
Continuity Tests
Advantages of KF-32
Easy-to-read large characterDC12A RangesBig current can be measured in DC 12A range.
Scale plate with mirrorThe mirror to help the correct reading avoiding the reading error.
Test Leads with gold plated pins
Advantages of SK-8301
Triaxial ELF Magnetic Field Meter
True RMS! High Performance!
APOMAXM I N
AVERAGE
FEATURES●Accurate Measurement by Triaxial Sensor.●True RMS.
SK-8301 TRIAXIAL ELF MAGNETIC FIELD METER
Range20.00μT200.0μT200.0mG2000mGMAX/MIN, Average, Display Hold, Auto Power Off
Resolution0.01μT0.1μT0.1mG1mG
Accuracy±2%rdg±5dgt (50/60Hz)±5%rdg±5dgt (40Hz to 1kHz)±2%rdg±5dgt (50/60Hz)±5%rdg±5dgt (40Hz to 1kHz)
Maximum. Input
200.0μT
2000mG
::::::::::
SPECIFICATIONSDisplayOperating PrincipleSampling RateRange SelectionRectificationPower SupplyCE MarkDimensions WeightAccessories
2000 count LCD, Maximum Reading 2000 Triaxial True RMS (X, Y, Z)2 times / secondAuto RangingTrue RMS1.5V R6P or AA Batteries (x 2)EMC test passed148(H) x 83(W) x 33(D) mm, 220g1015 Carrying Case1.5V R6P Batteries (x 2)
μTmeasurement
mGmeasurementFunctions
DISPHOLDμT mG
Electromagnetic comes from mixed directions if multiple sources are existing. Even in such field., SK-8301 can measure correct magnetic flux density by its triaxial (X, Y, Z) sensor.
X:Right and leftY:Back and forthZ:Up and Down
Y
X
Z
SK-8301
TRIAXIAL ELFMAGNETIC FIELD METER
Y
X
Z
REC DH
DISPLAYHOLD POWERMAX / MIN
AVG
In the field of multipleelectromagnetic sources
Accurate Measurement by Triaxial Sensor
True RMSDue to large distortion contained in electromagnetic wave, measurement result by average rectification meter should be incorrect. SK-8301 measures in True RMS and the measurement result is always accurate.
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
35
Digital Sound Level Meter
For Sound Level Check of Living Environment
FEATURES●Select frequency weighting (A/C).●Select time weighting (FAST/SLOW).●Rubber Grip.●MAX/MIN measurement.●Display Hold.●Auto Power Off.
SPECIFICATIONSDisplayMeasuring RangeAccuracySampling RateTime WeightingPower Supply Dimensions WeightAccessories
:::::::::
11mm high 30dB to 125dB (A Weighting / C Weighting) ±5dB2 times/second125ms (FAST mode) or 1s (SLOW mode)9V 6F22 x 1193(H) x 67(W) x 44(D) mm 184gWind Screen, 9V 6F22 Battery x 1(Installed),
OPTIONAL ACCESSORIES1026 Carrying Case
Sound Level
120dB
110dB
100dB
90dB
80dB
70dB
60dB
50dB
40dB
30dB
20dB
Sound Example
Airplane take off at 300m
Car horn at 2m
Chain saw
Noisy factory
Subway inside (open-window), Piano
Vacuum cleaner, Noisy office
Normal conversation, TV sound
Quiet office
Library
Whispering voice
Leaves rustling
KG-70
APOLUX MAXM I N
DISPHOLD
Sound levels in everyday lifeNoisy sound such as from factory, airplane, or automobile sometimes disturbs our comfortable life.Generally, quiet sound level in everyday life is less than 45dB, Comfortable sound level will be around 40dB to 60dB.
APOdBSOUND MAX
M I NDISPHOLD
Verypainful
Verynoisy
Loud
Moderate
Quiet
Measurement Procedures①Press POWER Key and turn the power on.②Remove the sensor cap.③Hold out the sensor to the object to be measured.④Read the measurement value on LCD.
Digital Light Meter
For Illuminance Testing for Indoor Facilities
FEATURES● Lux and Fc (foot-candle) are selectable.●Backlight LCD.●Rubber Grip.●MAX/MIN measurement.●Display Hold.●Auto Power Off.
SPECIFICATIONSDisplaySensorMeasuring RangeSampling RateRange SelectionPower Supply Dimensions WeightAccessories
:::::::::
11mm high Silicon photodiode and filter0 to 99990Lux, 0 to 9999Fc 2.5 times/secondAuto Ranging9V 6F22 x 1192(H) x 67(W) x 44(D) mm 198g9V 6F22 Battery x 1(Installed),
OPTIONAL ACCESSORIES1026 Carrying Case
KG-75
LCD shows ×10 sign whenmeasurement value exceeds9999Lux. Example : 56180Lux
Measurement units1Lux : Equal to one lumen per square meter.1Fc : Equal to one lumen per square feet.1Lux ≒ 0.09290Fc 1Fc ≒ 10.764Lux
"x10" lights up
Accuracy
0 to 300Lux:±6%±3dgt301 to 4000Lux:±6%4001 to 99990Lux:±10%
Backlight, MAX / MIN, Display Hold, Auto Power Off
Resolution0.01Lux0.1Lux1Lux10Lux
Range0.00 to 19.99Lux20.00 to 199.9Lux200 to 9999Lux1000 x 10 to 9999 x 10LuxFunctions
Advantages of SK-8530
Backlight LCDEasy reading even in the dark places.
MAX/MIN measurementDisplay should change as following by pressing MAX/MIN Key.
Display HoldFreeze the readings by pressing HOLD Key.
Auto Power OffPower turns off automatically after approx. 5 minutes of last operation.
Rubber GripSide rubber assures good grip neatly fit in your hand.
Clam
p Meters
Insulation Testers / Earth TesterD
igital M
ultim
etersA
nalo
g Mu
ltitestersA
uto
mo
tive Testers
Oth
er Testers
Accesso
ries
100-40Lead Wires
(Red x 2, Black x 1)
795Test Pins
(Red x 2, Black x 1)
942BAlligator Clip
(Black x 1)
100-72 Oscilloscope Test Lead Set
Narrow test pins that can insert wire harness.Included 2 sets of red test leads / test pins allows 2-channels measurement. Use black alligator clip for grounding.
Changeable
100-74 Ripple Voltage Test Lead
Major test lead for our products. Gold-plated pins assures long-lastingcontact.
Gold platedpins
100-57 Test Leads
Applicable ModelsSK-7682 / 7718 / 7719 / 7720 / 7722 / 7708
7615 / 7625 / 6161 / 6163 / 6150 / 40334035 / 6166
36
Test Leads
100-41 Test Lead Kit
Connect Test Plugs and Test Pipes of 100-40 Lead Wire, and connect 3 kinds of Test Pin or 2 kinds of Test Hook.
Test Plug of100-40 Lead Wires
767 / 769 / 792 Test Pin790 / 791 Test Hook766 Test Pipes
Applicable ModelsSK-2500 / 7682 / 7718 / 7719 / 7720 / 7722 / 7708 / 7615 / 7625 / 6161 / 6163 / 6150 / 4033
4035 / 6166KU-2600 / 2602 KF-32 / 20 KT-2021
Newly-developed test lead for our mini-clamp meter series.+ / - integrated connector that can hardly pulled out during measurement.
Test Leads
Applicable ModelsSK-7660 / 7661 / 7602 / 7603 / 7820 / 7825
Connector
Test PipesMax. Voltage : 1000VMax. Current : 10A
Alligator ClipsMax. Voltage : 1000VMax. Current : 20AJaw Opening : 20mm
Test Pin
100-40Lead WiresWire Length : 1.6mMax. Voltage : 1000VMax. Current : 10A
1002Carrying case
Straight Test PinTest HookL Type Test Pin
15mm
100-40Lead Wire
766RRed Test Pipe
942BBlack
Alligator Clips
792RRed Straight
Test Pin
Test Lead SetLead WiresRed Test PipeRed Straight Test PinBlack Alligator Clip
Models100-40766R792R942B
Applicable ModelsSame models 100-41
Test Lead SetCombination of useful components from 100-41.
*Red and black parts are contained except for 790 and 791.
Test Lead KitLead WiresTest PipesTest PinsL Type Test PinsTest Hook for Dark CurrentTest Hook for Dark CurrentStraight Test PinsAlligator Clips
Models100-40766767769790791792942
ModelsLength of PinInside DiameterTip DiameterMax. VoltageMax. Current
76719mm-
φ2mm1000V10A
79225mm-
φ0.5mm100V1A
76915mm-
φ0.9mm1000V1A
79068mmφ10mmφ0.9mm100V1A
79174mmφ16mmφ0.9mm100V1A
Applicable ModelsSK-2500
Applicable ModelsSK-2500
Can view the Ripple Voltage waveform of the alternator by removing DC elements from the measuring voltage.
Battery
alternator
B Terminal100-74 Test Lead (Red)
100-57 Test Lead (Black)(Supplied with SK-2500)
HANDY OSCILLOSCOPE
Cla
mp
Met
ers
Insu
latio
n Te
ster
s / E
arth
Test
erD
igit
al M
ult
imet
ers
An
alo
g M
ult
ites
ters
Au
tom
oti
ve T
este
rsO
ther
Tes
ters
Acc
esso
ries
37
Temperature Probe Clamp Adapter
Applied for the testers that have temperature measurement function.
818-02 Temperature Probe
Measurement-50℃ to 100℃
Applicable ModelsSK-2500 / 7720 / 7722KU-2602KT-2021
AC / DC Clamp Adapter660 can measure up to 400A AC / DC by using in combination with Digital Multimeters that can measure 400mV AC / DC.
MeasurementAC 0 to 400ADC 0 to 400A
Applicable ModelsKU-2600 / 2602SK-6161 / 6163 / 6150 / 4033 4035 / 6166KT-2021
Battery Cable
Replaceab le bat tery cab le by onescrewdriver.
Applicable ModelsSK-8550
Alligator Clips
Applicable ModelsSK-7660 / 7661 / 7682 / 7718 / 7719 / 7720 / 7722 / 7708
7602 / 7603 / 7615 / 7625 / 7820 / 7825 / 3500* / 3502*6161 / 6163 / 6150 / 6597 / 6592 / 4033 / 4035 / 65556500 / 6166
KU-2600 / 2602 / 1199 KF-32 / 20
*Only red clip is available for SK-3500 / 3502.
Applicable ModelsSK-7660 / 7661 / 7718 / 7719 / 7720 / 7722 / 7708 / 7602
7603 / 7615 / 7625 / 7820 / 7825 / 3500* / 3502* / 61616163 / 6150 / 6597 / 6592 / 4033 / 4035 / 6555 / 6500
KU-2600 / 2602 / 1199 KF-32 / 20*Only red clip is available for SK-3500 / 3502.
Alligator Clips
CE Mark : CAT Ⅱ 300V class 2 and EMC
*Can not use for SK-8530 / SK-8535.
819 Temperature Probe
Measurement-50℃ to 700℃
Applicable ModelsSK-2500 / 7720 / 7722KU-2602KT-2021
Test Pins
Clips
Coil-Type Contact Pin
Extra fine test pin. It takes care not to scratch the object by spring structure.
Applicable ModelsSK-7660 / 7661 / 7682 / 7718 / 7719 / 7720
7722 / 7708 / 7602 / 7603 / 7615 / 76257820 / 7825 / 6161 / 6163 / 6150 / 65976592 / 4033 / 4035 / 6555 / 6500 / 6166
KU-2600 / 2602 / 1199 KF-32 / 20 KT-2021
φ0.4mm
This test pin is suitable for narrow point measurement. That can measure with inserting the pin to the backside of insulation coupler of the car.
Test Pin
Applicable ModelsSK-2500 / 7661 / 7682 / 7718 / 7720 / 7722
6166 / 6597 / 6594 KT-2021
φ0.4mm
Max. Current : 1A Max. Voltage : 50V
Straight Test Pin
φ0.5mm
Extra fine and elastic test pin only 0.5mm diameter, that is very suitable for narrow point measurement. Insulation coated bottom to prevent incorrect measurement.
Applicable ModelsSK-6592 / 6597 / 100-41
*Only red pin is available for SK-6592 / 6597 / 6598.
Max. Current : 1A Max. Voltage : 50V
Extra fine test pin only 0.5mm diameter. It is very suitable for narrow point measurement. Use it with connecting to 100-40 test plug.※Difference from 792 straight test pin : 795 can connect to 100-40 directly without 766 test pipes.
Test Pin
Applicable ModelsSK-8402 / 100-40 / 100-72
Max. Current : 1A Max. Voltage : 50V
φ0.5mm
817-03 / 17 / 19 / 25 Temperature Probe [TYPE K (CA)]
MODEL Tip Form Dimensions
φ14
98
φ1.6 SUS316
150
φ3.2 SUS316
150
φ14
98
φ3.2 SUS316
150
φ14
98
500 125
φ15φ5.0817-03
817-17
817-19
817-25
2~3 5
Unit : mm
Liquid Temp.
Internal Temp.
Internal Temp.
Air Temp.
Measurement817-03 : -50℃ to 1150℃817-17 : -50℃ to 600℃
Applicable ModelsSK-7720 / 7722KU-2602 / KT-2021
817-19 : -50℃ to 750℃817-25 : 0 to 200℃
800 Battery Cable
Printer Paper
Optional printer paper for SK-8530 / 8535 / 8550 Battery Checkers.
Applicable ModelsSK-8530 / 8535 / 8550
QuantityWidthLength
10 rolls / set Approx. 57mmApprox. 5.8m
851 Printer Paper
Mark Descriptions
38
CapacitanceCapacity of electronic capacitor (electrostatic capacity) is measurable in F (farad) unit.
Diode Test Diode test is possible measuring its forward and reverse side.
TemperatureTemperature is measurable using the temperature probes.
AC CurrentAC Current measurement is possible.
AC
A
DC CurrentDC Current measurement is possible.
DC
A
FrequencyFrequency measurement is possible.Hz
Decibel (low-frequency output)Low frequency output like audio amplifier is measurable in dB (decibel) unit.
dB
Pulse WidthWaveform pulse width for logic or switching controls are measurable in ms (milli-second) unit.
PULSEWIDTH
Dwell AngleElectricity time for automobile engine is measurable converting into an angle.
DWELLANGLE
Revolutions Per MinuteRPM of automobile engine is measurable.
RPM
AC VoltageAC Voltage measurement is possible.
AC
V
Duty CycleThe duty cycle of repeating waveform is measurable and indicated in a percentage basis(%).
DUTY
%DC VoltageDC Voltage measurement is possible.
DC
V
ResistanceResistance measurement is possible.Ω
Continuity TestThe buzzer sounds when the measuring object is electrically conducting.
Low ResistanceLow Resistance measurement is possible.Ω
LOW
Sound LevelNoise level measurement is possible.
IlluminanceIlluminance measurement is possible.
TRUERMS
True RMS (True root-mean-square value)True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
APOAuto Power OffPower is automatically turned off when a certain period of time has elapsed after the power on. Some models are enabled to cancel this function.
APSAuto Power SaveDisplay is automatically turned off and into power save condition when a certain period of time has elapsed after the power on. Some models are enabled to cancel this function.
Simple WaterResistant
Simple Water ResistantWater-Resistant case is used to protect the tester from water damage.
DATAMEMO
Data MemoryMeasurement data can be saved in internal memory.
AUTOZERO
Power-On InitializeAutomatic Zero-Adjustment function to adjust LCD indications into 0±1 digit when powered on.
DropProof
Drop ProofAnti-shock structure enables to protect the tester from the strong shock by the 1-meter-dropping-off.
OUTPUT
Output TerminalAn output terminal connectable to the Oscilloscopes or Recorder is available.
DustProof
Fireproof
Dust ProofDust-proof case is used to protect the tester from dust damage.
LPFLow Pass FilterFrequency signals higher than the specified cutting-off frequency are intercepted.
Backlight LCDUseful for easy reading even in dark areas.
DISPHOLD
Display HoldEnables to hold the indicating values on LCD. Useful to note down the measurement values.
MAXM I N
MAX / MINThe minimum and maximum of the measurement values are measurable and indicates on LCD.
AVERAGE
AverageThe average of the measurements value for a certain period of time is measurable.
PEAKHOLD
Peak HoldThe Peak current value in a certain period of time is measurable and indicates on LCD.
DIFFDifferenceA certain measurement value is stored and converted into zero. The difference between measuring value and stored value is indicated with proceeding measurements.
RNGHOLD
Range HoldEnables to hold the ranges when the Current or Voltage values are unstable and difficult to read.
Measurement Items
Measurement Functions
Battery TestBattery voltage and its condition are tested applying a certain current to the tester.
BATT.TEST
Fireproof CaseThe fireproof case protects the instrument inside from fire.
Magnetic FieldMagnetic Field measurement is possible.
μT mG
BARGRAPH
BargraphBar Graph is available on LCD. Zoom-up function is available for some models.
COMPComparator (Comparing function)Buzzer sounds when the input value is beyond the specified high and low limits.
PENLIGHT
PenlightBrightly illuminate test points with LED light. Useful for testing in dark place.
Error inputwarning
Error input warning Safety function to prevent incorrect test lead connection.
LUX
dBSOUND
www.kaise.com
DISTRIBUTOR
70-0201-0000-7 1703
422 Hayashinogo, Ueda City, Nagano Pref., 386-0156 Japan
Telephone : +81-268-35-1601 Fax : +81-268-35-1603
E-mail : [email protected]