Oxycon Pro™ - CareFusion · Oxycon Pro™ Cardiopulmonary Exercise Testing by JAEGER™ Highest...

2
Oxycon Pro™ Cardiopulmonary Exercise Testing by JAEGER™ Highest Quality with more than four decades of experience Top of the line professional equipment Breath by Breath or Mixing chamber Intrabreath including Flow- Volume Loop during exercise Integrated ECG Nutritional Assessment by Canopy or on ventilated patients Cardiac Output - CO 2 rebreathing High/Low FIO 2 / Respiratory Drive P0.1 during Exercise Complies with international regulations, MDD and FDA Outpatient Monitoring Sleep Diagnostics & Therapy Lung Function Diagnostics Point-of-Care Diagnostics Cardiorespiratory Diagnostics Ventilation CareFusion Respiratory Care Your partner: Intrabreath measurement at 50 watts Intrabreath measurement at 120 watts Intrabreath: Testing during Exercise Subjects whose Flow-Volume Loop is considerably reduced cannot exercise to a maximum. The Intrabreath pro- gram superimposes each exercise Flow-Volume Loop over the resting loop for easy evaluation of possible ventila- tory limitations. Intrabreath also reports both EELV and IC for each measurement. Standard Features Full-featured exercise test including Flow-Volume- Loop Breath-by-Breath measurement AT, AE, RCP determination according to different methods Intrabreath measurement for dynamic Flow-Volume Loop Automatic volume and gas calibration Ambient module for temperature and pressure Calculated nutritional assessment Calculated Cardiac Output (Wasserman) Off-line blood gases/lactate and AaDO 2 determination Training and nutrition reports Interpretation program IntelliSupport Automatic ergometer control Program to design own reports and screen layout Options: Options: Options: Options: Options: Mixing chamber measurement mode Measured Cardiac Output by CO 2 rebreathing Nutritional assessment using canopy or on ventilated patients High/Low FIO 2 / Respiratory Drive P0.1 during exercise Program „Lactate Express CPET“ for training recommendation Fully integrated 12-lead ECG Interface for GE-ECG CardioSoft, Custo ECG, AmedTec ECG, Medset ECG Dual Monitor Bicycle or treadmill ergometer Pulse Oximetry Network / GDT / HL7 connection Unlimited networking possibilities The JLAB database is fully networkable. Whether you intend to network a single system or multiple Oxycon and MasterScreen systems, only one central database on a single server is needed. Enter patient data only once, or import from the practice administration system using the GDT interface, or import from the Hospital Interface System using VLINK. Of course, data can also be exchanged vice versa. Choose between workstations that view and print reports only, or are also able to edit the data. Workstations using JINET Server only require an internet browser and Acrobat Reader. You can also create a report in PDF format and save it to any location in your network. Contact us for detailed information. Contact us for detailed information. Contact us for detailed information. Contact us for detailed information. Contact us for detailed information. carefusion.com Europe: CareFusion Germany 234 GmbH Leibnizstrasse 7 97204 Hoechberg +49 931 4972-0 tel +49 931 4972-423 fax USA: CareFusion Respiratory Care 22745 Savi Ranch Parkway Yorba Linda, CA 92887 +1 714 283 2228 tel +1 714 283 8493 fax © 2009 CareFusion or one of its affiliates. All rights reserved. JAEGER is a trademark or registered trademark of CareFusion Corporation or one of its affiliates. PN 791965

Transcript of Oxycon Pro™ - CareFusion · Oxycon Pro™ Cardiopulmonary Exercise Testing by JAEGER™ Highest...

Oxycon Pro™

Cardiopulmonary Exercise Testing by JAEGER™Highest Quality with more than four decades ofexperience

Top of the line professionalequipment

Breath by Breath or Mixingchamber

Intrabreath including Flow-Volume Loop during exercise

Integrated ECG

Nutritional Assessment byCanopy or on ventilatedpatients

Cardiac Output -CO2 rebreathing

High/Low FIO2 / RespiratoryDrive

P0.1 during Exercise

Complies with internationalregulations, MDD and FDA

Outpatient Monitoring

Sleep Diagnostics & Therapy

Lung Function Diagnostics

Point-of-Care Diagnostics

Cardiorespiratory Diagnostics

Ventilation

CareFusionRespiratory Care

Your partner:

Intrabreath measurement at 50 watts Intrabreath measurement at 120 watts

Intrabreath: Testing during ExerciseSubjects whose Flow-Volume Loop is considerably reduced cannot exercise to a maximum. The Intrabreath pro-gram superimposes each exercise Flow-Volume Loop over the resting loop for easy evaluation of possible ventila-tory limitations. Intrabreath also reports both EELV and IC for each measurement.

Standard Features Full-featured exercise test including Flow-Volume-

Loop Breath-by-Breath measurement AT, AE, RCP determination according to different

methods Intrabreath measurement for dynamic

Flow-Volume Loop Automatic volume and gas calibration Ambient module for temperature and pressure Calculated nutritional assessment Calculated Cardiac Output (Wasserman) Off-line blood gases/lactate and AaDO2

determination Training and nutrition reports Interpretation program IntelliSupport Automatic ergometer control Program to design own reports and screen layout

Options:Options:Options:Options:Options: Mixing chamber measurement mode Measured Cardiac Output by CO2 rebreathing Nutritional assessment using canopy or on

ventilated patients High/Low FIO2 / Respiratory Drive P0.1 during exercise Program „Lactate Express CPET“ for training

recommendation Fully integrated 12-lead ECG Interface for GE-ECG CardioSoft, Custo ECG,

AmedTec ECG, Medset ECG Dual Monitor Bicycle or treadmill ergometer Pulse Oximetry Network / GDT / HL7 connection

Unlimited networking possibilitiesThe JLAB database is fully networkable. Whetheryou intend to network a single system ormultiple Oxycon and MasterScreen systems,only one central database on a single serveris needed. Enter patient data only once, orimport from the practice administrationsystem using the GDT interface, or importfrom the Hospital Interface System usingVLINK. Of course, data can also beexchanged vice versa. Choose betweenworkstations that view and print reportsonly, or are also able to edit the data.Workstations using JINET Server only requirean internet browser and Acrobat Reader. You canalso create a report in PDF format and save it to anylocation in your network.Contact us for detailed information.Contact us for detailed information.Contact us for detailed information.Contact us for detailed information.Contact us for detailed information.

carefusion.com

Europe:CareFusion Germany 234 GmbHLeibnizstrasse 797204 Hoechberg+49 931 4972-0 tel+49 931 4972-423 fax

USA:CareFusion Respiratory Care22745 Savi Ranch ParkwayYorba Linda, CA 92887+1 714 283 2228 tel+1 714 283 8493 fax

© 2009 CareFusion or one of its affiliates.All rights reserved.JAEGER is a trademark or registered trademarkof CareFusion Corporation or one of its affiliates.PN 791965

Evaluation of Anaerobic Threshold

Highly-precisedigital TripleV Sensor

Trolley with moderndesign and adjustabledesk; computer, printerand isolationtransformer included.

Option:12-lead-ECGwith KISS suction unitand 3-dimensionalswivel arm(Suction system notavailable in US)

Option: High Quality treadmill LE 200 CE with running surface 150 x 50 cm(other sizes up to 300 x 125 cm available)Alternate treadmill options for some countries

Integrated 12-lead-ECGOxycon Pro can be combined with a 12-lead-ECG forexercise and resting ECG. Make your choice - either theJaeger ECG which is fully integrated in the JLAB database, orthe high-end ECG CardioSoft from GE. With both, you caneasily perform a single exercise or resting ECG - also withoutdoing a complete cardiopulmonary exercise test. Furtheroptions like dual monitor or suction unit will provide morecomfortable testing. Simple pulse measurements are possiblewith the optional Polar belt or pulse oximeter.

Operation: Easy and quickly to comprehend

High-end gas analyzerOxycon Pro

Option: Swivel-mountedlateral desk

Volume and gas analzyer calibrations aredone automatically. A manual calibrationpump is not required.

Oxycon is cost effectiveOxycon Pro is a paradigm of cost effectiveness.The system is featured by gas analyzers with along economic lifetime and minimum gas con-sumption during calibration (50 mL).

With the optional “Online Service Agreement”you can make use of cost-saving and quicksupport without requiring a service technician totravel to your site.

CompetenceExercise testing is a very complex issue. At theroots of the concept of Oxycon Pro stands aninternational team of experts. They will be happyto answer any questions you may have.Furthermore, we offer theoretical and practicalCPET seminars as well as interpretation courses.

The TThe TThe TThe TThe TestestestestestDon’t leave anything to chance. The program provides you with variousbreath-by-breath displays, each configurable. Just click to jump to differentdisplays:

Breath-by-Breath andIntrabreath

The nine-panel graph byWasserman can alreadybe displayed during thetest. Automatic self-adjust-ing axis scaling ensuresoptimal display.

„Custom displays can becreated individually “

Nine-panel graph

Full-screen display

If you want to view a spe-cific curve simply double-click on the desired graphand a full-screen graphwill be displayed. This isStandard Windows tech-nology!

Combined graph:Oxycon Pro and ECG„ECG including automaticST measurement“

EvaluationEvaluationEvaluationEvaluationEvaluationThe data can be evaluated directly after collection orif desired, be evaluated later as Oxycon Pro allowsyou to read previously stored tests. Evaluation is fo-cused on the determination of the Anaerobic Thresh-old (AT). Different methods such as V-Slope, Breath-ing Equivalent, RQ=1 and Lactate are available. Themeasured values will be displayed at AT to perform aplausibility check. Further thresholds like AE (Aerobicthreshold) or RCP (Respiratory Compensaton point)can be set.

Interpretation programIntelliSupportIntelliSupportIntelliSupportIntelliSupportIntelliSupport, a graphics-based expert system,supports the busy physician in data analysis. Basedon the accepted guidelines and predicted valuesdescribed by the world-renowned Professor KarlmanWasserman, IntelliSupport uses decision trees toguide the clinician through the data accumulatedduring a test to arrive at a suitable interpretation.

Oxycon Pro and JaegerECG in single monitor use

Cardiac OutputCardiac output can either be measured by CO2rebreathing and/or dynamically calculated accordingto Wasserman‘s criteria. For assessment of cardiacinsufficiency and risk special slopes, parameters suchas VE/VCO2 are calculated.

Cardiac Output measurement with CO2 rebreathing

Oxycon Pro™: Expert system for routine andextended applicationsWe have taken careful note of the clinician’s requirements to createa top-of-the-line system which offers the full spectrum of cardiopul-monary measurements. Oxycon Pro not only allows you to run acomplete exercise test quickly and easily, but also offers many ad-vanced features, such as 12-lead stress ECG, mixing chambermode, measured cardiac output, high/low FIO2, P0.1 during exer-cise and various possibilities for nutritional assessment.

Volume Sensor: Precise and lightweightOur patented digital TripleV-Volume Sensor complies with ATS crite-ria, performs without drift and is completely insensitive to moisture.This is highly sophisticated technology you can truly rely upon. Ascompared to a turbine, the flat fan system has no starting or hunt-ing problems due to its small inertia. Thanks to its compact andlightweight design (45 g only), the sensor adds minimal resistanceto airflow and has a dead space of only 30 mL. Patients and ath-letes will highly appreciate the fact that it is extremely comfortableto wear with both mask and mouthpiece.The TripleV-Volume Sensor can be used for all groups of patientsfrom children to adults and critically ill patients to athletes.

IntelliSupport interpretation program

Automatic calibration

Automatic volume calibration

Automatic gas analyzer calibration

Every system is as good as its operator. Oxycon’s easy-to-use oper-ation ensures that you can quickly master the system, and not viceversa.

Automated program sequences, controlled by a singlekey, letting you concentrate on your patient ratherthan on computer monitors. Is there anything easier?

Option: Dual Monitor,ECG and exercise data onseparate TFT screens

Exercise testing and dy-namic Flow-Volume Loopduring exercise

40 Years of Experience in Exercise Testing

Dilution Canopy

Nutritional AssessmentOxycon Pro supports different methods to determineREE (Respiratory Energy Expenditure) including a dif-ferentiation between carbohydrates, fats and proteins.During the standard exercise test these parameterswill be calculated automatically. As an option, thegold standard canopy method with dilution techniquefor REE studies is available. Furthermore, ventilatedpatients can also be measured.

High/Low FIO2 and P0.1 during exerciseFor special studies with an increased level of oxygen theoption „High/Low FIO2“ is available. Studies with up to90% O2 are possible withthe special Eschenbachertransformation.A further special applicationis the measurement of therespiratory drive. By addingCO2 to the inspiration, thereaction of the breathingsystem can be determinedand controlled.Last but not least, the Oxycon Pro even allowsdetermining the respiratory muscle strength via the P0.1measurement during exercise.

Option: GE ECG CardioSoft CAM USB

ExportThe measured data can be easily exported into Excel®

for further investigation or into the special program„Lactate Express CPET“ for creating lactate thresholds,training ranges and individual training plans.