PP60 Pellet Stove
Model(s):PP60
HOT SURFACES! Glass and other surfaces are hot during operation AND cool down.
Hot glass will cause burns.• Do not touch glass until it is cooled• NEVER allow children to touch glass• Keep children away• CAREFULLY SUPERVISE children in same room as
fireplace.• Alert children and adults to hazards of high temperatures• High temperatures may ignite clothing or other
flammablematerials.• Keepclothing, furniture,draperiesandotherflammable
materials away.
WARNING
If the information in these instruc-tionsisnotfollowedexactly,afiremay result causing property dam-age, personal injury, or death.
• Donotstoreorusegasolineorotherflam-mablevaporsandliquidsinthevicinityofthis or any other appliance.
• Donotoverfire-Ifheaterorchimneycon-nectorglows,youareoverfiring.Overfiringwill void your warranty.
• Complywithallminimumclearancestocombustiblesasspecified.Failuretocom-plymaycausehousefire.
Questions, problems, missing parts? Before returning to your retailer, call our
customer service department at 877-427-3316.
WARNING
SAFETY NOTICE: PLEASE READ THIS ENTIRE MANUALBEFORE INSTALLATIONANDUSEOFTHISPELLETFUEL-BURNINGROOMHEATER. FAILURETO FOLLOWTHESEINSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE,BODILYINJURYOREVENDEATH.CONTACTLOCALBUILD-INGOFFICIALSABOUTRESTRICTIONSANDINSTALLATIONINSPECTIONREQUIREMENTSINYOURAREA.
Owner’s ManualInstallation & Operation
INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference.
NOTICE: DO NOT DISCARD THIS MANUAL
NOTEToobtainaFrenchtranslationofthismanual,pleasecontactyour dealer or visit www.pelprostoves.com
Pourobtenirunetraductionfrançaisedecemanuel,s’ilvousplaît contacter votre revendeur ou visitez www.pelprostoves.com
![Page 2: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/2.jpg)
7083-171B • July 23, 2013 (877) 427- 33162 7077-195•June27,2013
QUICK START GUIDE
4. Checkallthreebafflesarehookedintoslots.
*Beforeyoupluginthisappliance,followtheseinstructions*
3. Verfiyfirepot’sorientationiscorrect.5. Plugpowercordintowallreceptacle.
*Greenlightwillstartflashingonetimepersecond*
NOTE:Ifthelightdoesnotchangetosolidgreen,turnthecontrolbacktooff,unplugtheapplianceandrepeatsteps5&6.
7. Stovewillfeedfortwominutes.*Greenlightwillstartblinkingcontinuously,toindicatestartupsequence*
NOTE:Allowtheunitfiveminutesforignitiontotakeplace.
8. Onceafirehasbeenestablishedintheunit,leavetheunitburningonMAXfor30minutestoallowthepainttocure.
NOTE:Odorsandvaporsreleasedduringinitialoperation.
•Curingofhightemperaturepaint.•Openwindowsforaircirculation.
*Odorsmaybeirritatingtosensitiveindividuals.
9. After30minuteshavepassed,turndialcontroltoOFF,andallowunittocoolcompletely.Onceunithascooled,opendoorandcleanfirepotaccordingtothecleaninginstructionsfoundontheinsideofthehopperlid,orintheownersmanual.
*Unitisnowreadytoresumenormaloperation*
6.Toprimethefeedtube,QUICKLYturnthedialcontrolfromOFFtoMAX,backtoOFF,thenbacktoMAX.
*Thelightshouldstopblinkingandlightupsolidgreen*
NOTE:Primingisonlyrequiredthefirsttimetheapplianceislit,orafterthehopperhasruncompletelyoutofpellets.
If ignition is missed, empty the fi repot and repeat step 4.
0-1
-2-3
-4
+1 +2+3
+4
AUTO
MAT
IC / AUTOMÁTICO / AUTOMATIQUE
OFF
MAX
MIN
ON
AUTO
ALARM
1. TurnDialControltoOFF.All material needs to be removed from the door
glass and fi rebox before operation (including door cling, EPA card, hardware
kit and desi-pack)
2. Addpelletstohopperandcloselid.
0-1
-2-3
-4
+1 +2+3
+4
AUTO
MAT
IC / AUTOMÁTICO / AUTOMATIQUEOFF
MAXMIN
ON
AUTO
ALARM
Back
HoleforIgniter
MAXIMUMPELLET LEVEL
Frontof
firepothasthelip CONFIDENTIAL PROPERTY OF HEARTH & HOME TECHNOLOGIES INC.
PART NAME:
DRAWN BY: SCALE: MATERIAL:
SHEET: PART NUMBER: REV:THIS PRINT IS CHECKED AND CONTROLLED BY THE ENGINEERING DEPARTMENTS OF HEARTH & HOME TECHNOLOGIES INC.ECO # DATE BYREV
UNLESS OTHERWISE SPECIFIED DIMS ARE INCHES[MM] & : TOLERANCES ARE: (2) PLACE DEC : ± 0.03 (3) PLACE DEC: ± 0.005 ANGLE: ± 2° FRACTION: ± 1/16OUTSIDE MATERIAL. NORMAL DIM & INSIDE MATERIAL. OUTSIDE APEX INSIDE APEX - DIMS ENCLOSED BY AN OVAL ARE CRITICAL DIMENSIONS
REVISIONS
ITEM PART NUMBER PART NAME QTY
02 RELEASE FOR TOOLING 72901 04/29/13 MCW
LABEL CONTROL PANELMCW 1:1 SEE NOTE
1 OF 1 7083-167 02
NOTE:1. MATERIAL: MYLAR2. ADHESIVE: 3M #468 PERMANENT ACRYLIC3. TEMPERATURE RATING: INK @ 325°F
TOOLING
3.75
2.81 4X R0.13
2
1
43
56
7
8
9
10LO
OFF HI
0-1-2
-3
-4+1 +2
+3+4
ON
AUTO
ALARM
CONFIDENTIAL PROPERTY OF HEARTH & HOME TECHNOLOGIES INC.
PART NAME:
DRAWN BY: SCALE: MATERIAL:
SHEET: PART NUMBER: REV:THIS PRINT IS CHECKED AND CONTROLLED BY THE ENGINEERING DEPARTMENTS OF HEARTH & HOME TECHNOLOGIES INC.ECO # DATE BYREV
UNLESS OTHERWISE SPECIFIED DIMS ARE INCHES[MM] & : TOLERANCES ARE: (2) PLACE DEC : ± 0.03 (3) PLACE DEC: ± 0.005 ANGLE: ± 2° FRACTION: ± 1/16OUTSIDE MATERIAL. NORMAL DIM & INSIDE MATERIAL. OUTSIDE APEX INSIDE APEX - DIMS ENCLOSED BY AN OVAL ARE CRITICAL DIMENSIONS
REVISIONS
ITEM PART NUMBER PART NAME QTY
A RELEASED 72906 06/20/13 MCW
LABEL OPERATION AND MAINTENANCEMCW NTS SEE NOTE
1 OF 1 7083-168 A
NOTE:1. MATERIAL: NON-ANODIZED ALUMINUM 0.020 THICK2. BACKGROUND: BLACK3. COPY: SILVER4. ADHESIVE: 3M #468 PERMANENT ACRYLIC5. TEMPERATURE RATING: -50°F TO 350°F
RELEASED - ---- ----- -
6.75
11.75 4X R0.13
2XBroken Exhaust Probe
Sonde d'échappement casséSonda de escape roto
1XEmpty Hopper
trémie videtolva vacía OFF
3XBroken Ambient Probe
Cassé la sonde ambianteSonda ambiente roto
4XFailed Ignition
allumage échouéde encendido no OFF
8XHigh Exhaust Temperature
Température d'échappement hauteAlta temperatura de escape
TroubleshootingDépannage / Solución de problemas
Reset From Error1. Determine error from above table.2. Correct error condition. (see Owner’s Manual for additional information.)3. Turn dial control to OFF position, wait 10 seconds.4. Follow STARTING instructions.
Réinitialisation des erreurs1. Déterminer l'erreur de tableau ci-dessus.2. Condition d'erreur correct. (voir le manuel du propriétaire pour plus
d'informations.)3. Tourner le cadran de commande en position OFF, attendez 10 secondes.4. Suivez les instructions de démarrage.
Restablecer de error1. Determinar el error de la tabla anterior.2. Condición de error correcto. (consulte el Manual del Propietario para
obtener información adicional.)3. Gire el dial de control en la posición OFF, espere 10 segundos.4. Siga las instrucciones de arranque.
Customer Service / Service Clients / Servicio al Cliente877-427-3316 www.pelprostoves.com
Daily / Quotidien / Todos los días 1 Bag / 1 Sac / 1 Bolsa
Empty Firepot / Creuset Vide / Brasero De Fuego Vacía Clean Firepot / Clean Creuset / Limpieza Brasero De Fuego
Weekly / Hebdomandair / Semanalmente 5 Bags / 5 Sacs / 5 Bolsas
Clean Holes / Nettoyer Les Trous / Limpie Los Ori�cios Remove Ash / Retirez Les Cendres / Quitar Las Cenizas
Monthly / Mensuel / Mensualmente 25 Bags / 25 Sacs / 25 Bolsas
1
23
Remove / Supprimer / Quitar Vacuum / Vide / Vacío
Maintenance / Entretien / Mantenimiento
7083-168
Operation / Opération / Operación
Automatic Mode *mode AutomatiqueModo Automático
Priming Fuelcarburant d'amorçage
cebado de combustible
Minimum / Maximum **minimale / maximale
mínimo / máximo
Starting1. Turn dial control to OFF position.2. Fill hopper with pellets.3. Turn dial control to desired setting.
Départ1. Tourner le cadran de commande en
position OFF.2. Remplir la trémie avec des granulés.3. Tourner le cadran de commande au réglage
désiré.A partir
1. Gire el dial de control en la posición OFF.2. Llene la tolva con perdigones.3. Gire el dial de control hasta la posición deseada.
Stopping1. Turn dial control to OFF position.2. Allow unit to cool before performing any maintenance.
Arrêt1. Tourner le cadran de commande en position OFF.2. Laissez refroidir avant d'e�ectuer toute opération de maintenance.
Parada1. Gire el dial de control en la posición OFF.2. Deje enfriar la unidad antes de realizar cualquier trabajo de mantenimiento.
* The appliance will automatically maintain the desired comfort level and shut down when level has been achieved.
L'appareil passera automatiquement maintenir le niveau de confort désiré et arrêter lorsque le niveau a été atteint.
El aparato mantendrá automáticamente el nivel de confort deseado y se cerrará cuando el nivel se ha logrado.
** The appliance will run continuously until switched to OFF or AUTOMATIC mode. L'appareil fonctionne de façon continue jusqu'à ce que passe en mode OFF ou AUTOMATIQUE. El aparato funciona continuamente hasta que cambia al modo OFF o AUTOMÁTICO.
2
1
43
56
7
8
9
10LO
OFF HI
CONFIDENTIAL PROPERTY OF HEARTH & HOME TECHNOLOGIES INC.
PART NAME:
DRAWN BY: SCALE: MATERIAL:
SHEET: PART NUMBER: REV:THIS PRINT IS CHECKED AND CONTROLLED BY THE ENGINEERING DEPARTMENTS OF HEARTH & HOME TECHNOLOGIES INC.ECO # DATE BYREV
UNLESS OTHERWISE SPECIFIED DIMS ARE INCHES[MM] & : TOLERANCES ARE: (2) PLACE DEC : ± 0.03 (3) PLACE DEC: ± 0.005 ANGLE: ± 2° FRACTION: ± 1/16OUTSIDE MATERIAL. NORMAL DIM & INSIDE MATERIAL. OUTSIDE APEX INSIDE APEX - DIMS ENCLOSED BY AN OVAL ARE CRITICAL DIMENSIONS
REVISIONS
ITEM PART NUMBER PART NAME QTY
02 RELEASE FOR TOOLING 72901 04/29/13 MCW
LABEL CONTROL PANELMCW 1:1 SEE NOTE
1 OF 1 7083-167 02
NOTE:1. MATERIAL: MYLAR2. ADHESIVE: 3M #468 PERMANENT ACRYLIC3. TEMPERATURE RATING: INK @ 325°F
TOOLING
3.75
2.81 4X R0.13
2
1
43
56
7
8
9
10LO
OFF HI
0-1
-2-3
-4
+1 +2+3
+4
ON
AUTO
ALARM
CONFIDENTIAL PROPERTY OF HEARTH & HOME TECHNOLOGIES INC.
PART NAME:
DRAWN BY: SCALE: MATERIAL:
SHEET: PART NUMBER: REV:THIS PRINT IS CHECKED AND CONTROLLED BY THE ENGINEERING DEPARTMENTS OF HEARTH & HOME TECHNOLOGIES INC.ECO # DATE BYREV
UNLESS OTHERWISE SPECIFIED DIMS ARE INCHES[MM] & : TOLERANCES ARE: (2) PLACE DEC : ± 0.03 (3) PLACE DEC: ± 0.005 ANGLE: ± 2° FRACTION: ± 1/16OUTSIDE MATERIAL. NORMAL DIM & INSIDE MATERIAL. OUTSIDE APEX INSIDE APEX - DIMS ENCLOSED BY AN OVAL ARE CRITICAL DIMENSIONS
REVISIONS
ITEM PART NUMBER PART NAME QTY
A RELEASED 72906 06/20/13 MCW
LABEL OPERATION AND MAINTENANCEMCW NTS SEE NOTE
1 OF 1 7083-168 A
NOTE:1. MATERIAL: NON-ANODIZED ALUMINUM 0.020 THICK2. BACKGROUND: BLACK3. COPY: SILVER4. ADHESIVE: 3M #468 PERMANENT ACRYLIC5. TEMPERATURE RATING: -50°F TO 350°F
RELEASED - ---- ----- -
6.75
11.75 4X R0.13
2XBroken Exhaust Probe
Sonde d'échappement casséSonda de escape roto
1XEmpty Hopper
trémie videtolva vacía OFF
3XBroken Ambient Probe
Cassé la sonde ambianteSonda ambiente roto
4XFailed Ignition
allumage échouéde encendido no OFF
8XHigh Exhaust Temperature
Température d'échappement hauteAlta temperatura de escape
TroubleshootingDépannage / Solución de problemas
Reset From Error1. Determine error from above table.2. Correct error condition. (see Owner’s Manual for additional information.)3. Turn dial control to OFF position, wait 10 seconds.4. Follow STARTING instructions.
Réinitialisation des erreurs1. Déterminer l'erreur de tableau ci-dessus.2. Condition d'erreur correct. (voir le manuel du propriétaire pour plus
d'informations.)3. Tourner le cadran de commande en position OFF, attendez 10 secondes.4. Suivez les instructions de démarrage.
Restablecer de error1. Determinar el error de la tabla anterior.2. Condición de error correcto. (consulte el Manual del Propietario para
obtener información adicional.)3. Gire el dial de control en la posición OFF, espere 10 segundos.4. Siga las instrucciones de arranque.
Customer Service / Service Clients / Servicio al Cliente877-427-3316 www.pelprostoves.com
Daily / Quotidien / Todos los días 1 Bag / 1 Sac / 1 Bolsa
Empty Firepot / Creuset Vide / Brasero De Fuego Vacía Clean Firepot / Clean Creuset / Limpieza Brasero De Fuego
Weekly / Hebdomandair / Semanalmente 5 Bags / 5 Sacs / 5 Bolsas
Clean Holes / Nettoyer Les Trous / Limpie Los Ori�cios Remove Ash / Retirez Les Cendres / Quitar Las Cenizas
Monthly / Mensuel / Mensualmente 25 Bags / 25 Sacs / 25 Bolsas
1
23
Remove / Supprimer / Quitar Vacuum / Vide / Vacío
Maintenance / Entretien / Mantenimiento
7083-168
Operation / Opération / Operación
Automatic Mode *mode AutomatiqueModo Automático
Priming Fuelcarburant d'amorçage
cebado de combustible
Minimum / Maximum **minimale / maximale
mínimo / máximo
Starting1. Turn dial control to OFF position.2. Fill hopper with pellets.3. Turn dial control to desired setting.
Départ1. Tourner le cadran de commande en
position OFF.2. Remplir la trémie avec des granulés.3. Tourner le cadran de commande au réglage
désiré.A partir
1. Gire el dial de control en la posición OFF.2. Llene la tolva con perdigones.3. Gire el dial de control hasta la posición deseada.
Stopping1. Turn dial control to OFF position.2. Allow unit to cool before performing any maintenance.
Arrêt1. Tourner le cadran de commande en position OFF.2. Laissez refroidir avant d'e�ectuer toute opération de maintenance.
Parada1. Gire el dial de control en la posición OFF.2. Deje enfriar la unidad antes de realizar cualquier trabajo de mantenimiento.
* The appliance will automatically maintain the desired comfort level and shut down when level has been achieved.
L'appareil passera automatiquement maintenir le niveau de confort désiré et arrêter lorsque le niveau a été atteint.
El aparato mantendrá automáticamente el nivel de confort deseado y se cerrará cuando el nivel se ha logrado.
** The appliance will run continuously until switched to OFF or AUTOMATIC mode. L'appareil fonctionne de façon continue jusqu'à ce que passe en mode OFF ou AUTOMATIQUE. El aparato funciona continuamente hasta que cambia al modo OFF o AUTOMÁTICO.
2
1
43
56
7
8
9
10LO
OFF HI
![Page 3: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/3.jpg)
www.pelprostoves.com 7083-171B•July23,2013 3
TABLE OF CONTENTS
Safety Alert Key:• DANGER! Indicatesahazardoussituationwhich,ifnotavoidedwillresultindeathorseriousinjury.• WARNING!Indicatesahazardoussituationwhich,ifnotavoidedcouldresultindeathorseriousinjury.• CAUTION! Indicatesahazardoussituationwhich,ifnotavoided,couldresultinminorormoderateinjury.• NOTICE:Indicatespracticeswhichmaycausedamagetotheapplianceortoproperty.
1 Listing and Code ApprovalsA.ApplianceCertification......................................................5B.MobileHomeApproved....................................................5C.GlassSpecifications.........................................................5D.ElectricalRating(OnHigh)...............................................5E.BTU&EfficiencySpecifications........................................5
2 General InformationA.FireSafety.........................................................................6B.Non-CombustibleMaterials..............................................6C.CombustibleMaterials.......................................................6D.FuelMaterialandFuelStorage........................................6E.BeforeYourFirstFire.......................................................6
3 General Operating InformationA.UserDialControl...............................................................7B.FillingtheHopper...............................................................7C.PrimingtheFeedTube......................................................7D.FirepotBurnDown.............................................................8E.Shutdown...........................................................................8F.StartingYourFirstFire........................................................8G.FireCharacteristics...........................................................8H.YourPelletAppliance-GeneralOperatingParts...............9I.LEDColorCodingChartandExplanation..........................10J.IgnitionCycles...................................................................11K.RunninginMinimumorMaximum.....................................11L.RunningintheComfortLevelMode..................................11M.ClearSpace......................................................................11N.TrimAdjustment.................................................................11
4 Maintaining & Servicing the ApplianceA.ProperShutdownProcedure.............................................12B.QuickReferenceMaintenanceChart.................................12C.GeneralMaintenance........................................................12D.HighAshFuelContentMaintenance.................................16E.FrequentlyAskedQuestions..............................................17
5 Replacement PartsA.ConvectionBlowerReplacement......................................18B.ExhaustBlowerReplacement............................................18C.SnapDiscReplacement...................................................19D.IgniterReplacement..........................................................19E.BaffleRemoval&Replacement........................................19F.GlassReplacement............................................................20G.ControlBoardReplacement..............................................20H.FuseReplacement............................................................20I.FeedMotorReplacement..................................................20J.FeedSpringReplacement.................................................20
6 Getting StartedA.Design,Installation&LocationConsiderations......................... 21B.Draft ..............................................................................21C.NegativePressure.............................................................21D.LocatingYourAppliance&Chimney.................................22E.InspectAppliance&Components......................................22F.ToolsAndSuppliesNeeded..............................................22
7 Dimensions and ClearancesA.ApplianceDimensions......................................................23B.ClearancestoCombustibles(ULandULC).......................23C.HearthPadRequirements(ULandULC)..........................24
8 Vent InformationA.ChimneyandExhaustConnection....................................25B.VentingTerminationRequirements....................................25C.PelletVentingCharts.........................................................26
9 Venting SystemsA.Vertical-Interior-TypicalInstallation................................27B.ThroughTheWall&Vertical-External-Horizontal..........27C.VerticalintoExistingClassAChimney..............................27D.Masonry.............................................................................28E.AlternateMasonry..............................................................28F.ThroughTheWall...............................................................29
10 Mobile HomeA.MobileHomeInstallation...................................................30
11 Appliance Set-UpA.OutsideAirKitInstructions................................................31B.PoweruptheUnit.............................................................31
12 Troubleshooting13 Reference Materials
A.ComponentFunction.........................................................35B.WiringDiagram..................................................................36C.ReplacementParts............................................................37D.Service&MaintenanceLog...............................................38E.Warranty............................................................................39
![Page 4: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/4.jpg)
7083-171B • July 23, 2013 (877) 427- 33164
CAUTIONAfter reading these instructions, if you have any doubtaboutyourability tocompleteyour installation inapro-fessionalmanner you should obtain the services of aninstallerversedinallaspectsastothecorrectandsafeinstallation. Do not use temporary makeshift compro-
misesduringinstallation.BEFORE INSTALLATION OF YOUR APPLIANCE
1.Checkwiththebuildinginspector’sofficeforcompliancewithlocalcodes;apermitmayberequired.2.Use3”or4”(76-102mm)diametertype“L”or“PL”ventingsystem.Itcanbeventedverticallyorhorizontally.Approvedadaptorscanbeusedtoconnectthe“L”or”PL”toapprovedwoodstoveventingsuchassinglewallordoublewallventingpreviouslyusedtoventawoodburningappliance.INSTALLVENTATCLEARANCESSPECIFIEDBYTHEVENTMANUFACTURE.3.AlwaysconnectthisunittoanapprovedchimneysystemandNEVERventtoanotherroomorinsideabuilding.4.DONOTINSTALLAFLUEDAMPERINTHEEXHAUSTVENTINGSYSTEMOFTHISUNIT.5.DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. 6.Theconnectorpipeandchimneyshouldbeinspectedperiodicallyandcleanedifnecessary.Reviewadditionalinformationlocatedinthemainte-nancesectionofthisOwner’sManual.7.Remembertheclearancedistanceswhenyouplacefurnitureorotherobjectswithinthearea.Thisincludesheatsensitivematerialssuchascandles,seasonaldecorationsordraperies.DONOTSTOREWOOD,FLAMMABLELIQUIDSOROTHERCOMBUSTIBLEMATERIALSTOOCLOSETOTHEUNIT.8.Beawareoftherequiredclearanceswhenlocat-ingtheunit.Refertothelabelontherearoftheunitforrequiredclearances.9.Contactyourlocalmunicipalorprovincialfireauthorityforinformationofhowtohandleachim-neyfire.Haveaclearunderstoodplantohandleachimneyfire.Intheeventofachimneyfire,CALL THE FIRE DEPARTMENT.10.Priortoburningtheunitforthefirsttimemakesurethehardwarekithasbeenremovedfromthefirebox.
IMPORTANTItishighlyrecommendedthatthepelletheaterandchimneybeinstalledbyaqualifiedinstaller.Aqualifiedinstallerisapersonorentitywhoregularlyinstallssolidburningfuelproductsandchimneysinthecourseoftheirordinarybusiness.
If the information in these instructions is not followed
exactly, a fire may result causing property damage, personal injury,
or death. • Donotstoreorusegasolineorotherflam-mablevaporsandliquidsinthevicinityofthisoranyotherappliance.
• Donotoverfire-Ifheaterorchimneycon-nectorglows,youareoverfiring.Overfiringwillvoidyourwarranty.
• Complywithallminimumclearancestocombustiblesasspecified.Failuretocomplymaycausehousefire.
WARNING
Hot glass will cause burns.• Donottouchglassuntilitiscooled• NEVERallowchildrentotouchglass• Keepchildrenaway• CAREFULLYSUPERVISEchildreninsameroomas
fireplace.• Alertchildrenandadultstohazardsofhigh
temperatures.High temperatures may ignite clothing or other flammable materials.• Keepclothing,furniture,draperiesandotherflammable
materialsaway.
HOT SURFACES!
GlassandothersurfacesarehotduringoperationANDcooldown.
WARNING
Fire Risk.
Testedandapprovedforwoodpellets.Burningofanyovertypeoffuelwillvoidyourwarranty.
WARNING
![Page 5: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/5.jpg)
www.pelprostoves.com 7083-171B•July23,2013 5
A. Appliance Certification
This appliance is equipped with 5mm ceramic glass.Replaceglassonlywith5mmceramicglass.PleasecontactPelproforreplacementglass.
B. Mobile Home Approved
NOTE: Thisinstallationmustconformwithlocalcodes.IntheabsenceoflocalcodesyoumustcomplywiththeASTM E1509-04, ULC S627-00, (UM) 84-HUD,
*BTUinputwillvary,dependingonthebrandoffuelyouuseinyourstove.**Heatingcapacitydependsonclimatezone,structurelayout,insulation,windows,etc.
MODEL: PP60Particulate Emissions Rating: 0.34grams/hr
*BTU Input: 11,000-35,000/hrEfficiency: 85%
**Heating Capacity: 750to1450sq.ft.dependingonclimatezone
Hopper Capacity: (Approx) 60lbsFuel: WoodPelletsShipping Weight: 205lbs
Series: PP60
Laboratory: IntertekReport No. 10072262PRT-001Type: SolidFuelRoomHeater/Pellet
FuelBurningTypeStandard: ASTME1509-04andULCS627-
00,RoomHeaterPelletFuelBurningtypeand(UM)84-HUD,MobileHomeApproved.
TheseheatersmeettheUSEvironmentalProtectionAgency’sEmissionlimitsforpelletheaters.UnderspecificconditionsthePP60stovehasshowntodeliverheatatratesrangingfrom9,550to25,080BTU/hr.
• This appliance is approved for mobile homeinstallationswhennotinstalledinasleepingroomandwhenanoutsidecombustionairinletisprovided.
• The structural integrity of the mobile home floor,ceiling,andwallsmustbemaintained.
• Theappliancemustbeproperlygroundedtotheframeofthemobilehomewith#8coppergroundwire,anduseonlylisteddouble-wallconnectorpipe.
• Outside Air Kit provided with each unit must beinstalledinamobilehomeinstallation.
WARNING! Risk of Fire! Pelprodisclaimsanyresponsibilityfor,andthewarrantyandagencylistingwillbevoidedbythebelowactions.DO NOT: • Installoroperatedamagedappliance • Modifyappliance • Installotherthanasinstructedbythemanufacturer. • Operatetheappliancewithoutfullyassemblingall
components • Overfire • Installanycomponentnotapprovedbythe manufacturer • InstallpartsorcomponentsnotListedorapproved • Disablesafetyswitches
Improper installation, adjustment, alteration, service ormaintenancecancauseinjuryorpropertydamage.Forassistanceoradditionalinformation,consultaqualifiedinstaller,serviceagencyoryourdealer.
PP60 Series: 115VAC,60Hz,Start2.6Amps,Run0.9Amps
C. Glass Specifications
D. Electrical Rating (On High)
E. BTU & Efficiency Specifications1 Listing and Code Approvals
![Page 6: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/6.jpg)
7083-171B • July 23, 2013 (877) 427- 33166
A. Fire SafetyToprovide reasonable fire safety, the following should begivenseriousconsideration:• Installat leastonesmokedetectoroneachfloorofyourhome.
• Installatleastonecarbonmonoxidedetectoroneachfloorofyourhome.
• Locatesmokedetectorawayfromtheheatingapplianceandclosetothesleepingareas.
• Followthesmokedetectormanufacturer’splacementandinstallationinstructionsandmaintainregularly.
• Followthecarbonmonoxidemanufacturer’splacementandinstallationinstructionsandmaintainregularly.
• ConvenientlylocateaClassAfireextinguishertocontendwithsmallfires.
• Intheeventofahopperfire: • Evacuatethehouseimmediately.
• Notifyfiredepartment.B. Non-Combustible MaterialsMaterialwhichwillnotigniteandburn,composedofanycombinationofthefollowing: -Steel -Plaster -Brick -Iron -Concrete -Tile -Glass -SlateMaterialsreportedaspassingASTM E 136, Standard Test Method for Behavior of Metals, in a Vertical Tube Furnace of 750° C.
C. Combustible MaterialsMaterialmadeof/orsurfacedwithanyofthefollowingmaterials: -Wood -CompressedPaper -PlantFibers -Plastic -Plywood/OSB -SheetRock(drywall)Anymaterialthatcanigniteandburn:flameproofedornot,plasteredorun-plastered.
D. Fuel Material and Fuel StoragePelletfuelqualitycangreatlyfluctuate.Werecommendthatyoubuyfuelinmulti-tonlotswheneverpossible.However,wedorecommendtryingvariousbrandsbeforepurchasingmulti-tonlotstoensureyoursatisfaction.FuelMaterial• Madefromsawdustorwoodby-products• Dependingonthesourcematerialitmayhaveahighorlowashcontent.HigherAshContentMaterial• Hardwoodswithahighmineralcontent• Fuelthatcontainsbark• Standardgradepelletsorhighashpellets
Fuel Material and Fuel Storage (Cont’d) LowerAshContentMaterial• Mostsoftwoods• Fuelswithlowmineralcontent•MostpremiumgradepelletsClinkersMineralsandothernon-combustiblematerialssuchassandwillturnintoahard,glass-likesubstancecalledaclinkerwhenheatedinthefirepot.Treesfromdifferentareaswillvaryinmineralcontent.Thatiswhysomefuelsproducemoreclinkersthanothers.MoistureAlwaysburndryfuel.Burningfuelwithhighmoisturecontenttakesheat from the fuel and tends to cool theappliance,robbingheatfromyourhome.Damppelletfuelcanclogthefeedsystem.Size• Pelletsareeither1/4inchor5/16inch(6-8mm)indiameter• Lengthshouldbenomorethat1-1/2inches(38mm)• Pellet lengths can vary from lot to lot from the same
manufacturer• Duetolengthvariations,thefeedratemayneedadjusting
occasionallyPerformance• Higherashcontentrequiresthefirepotandtheashdrawer
tobeemptiedmorefrequently• Hardwoodsrequiremoreairtoburnproperly• Premiumwoodpelletsproducethehighestheatoutput• Burningpelletslongerthan1-1/2inches(38mm)cancause
aninconsistentfuel feedrateand/ormissedignitionsoffeedjams.
Storage• Woodpelletsshouldbeleftintheiroriginalsealedbaguntilusingtopreventmoistureabsorption
• Donotstoreanypelletfuelwithintheclearancerequirementsor in an area that would hinder routine cleaning andmaintenance
E. Before Your First Fire1. First,make sure your appliance has been properly
installedandthatallsafetyrequirementshavebeenmet.Payparticularattentiontothefireprotectionandventing.
2. Doublecheckthatthefireboxisemptyandthefirepotisinplace!
3. Closeandlatchthedoor.
2 General Information
![Page 7: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/7.jpg)
www.pelprostoves.com 7083-171B•July23,2013 7
A. User Dial ControlTheappliancehasonedialcontrollocatedonthesideoftheunitusedfordailyoperation.Therearefourprimarysettingsonthisdial.
1) OFF:When thedial indicator is in the off positiontheunitwillgointoashutdownandremainoffuntilthedialisturnedtooneoftheotherthreesettings.TheLEDwillflashgreenoncepersecondwhenintheoffposition.
2)LO:WhenthedialindicatorisdirectedtotheLOsetting(smallflameonthelabel)theunitwillburnonlowuntilthehopperrunsoutofpelletsorthedialcon-trolisturnedtoadifferentsetting.WheninthissettingtheLEDwillbeamberincolorandcontinuouslyon.Whenburninginthismode,theunitshouldbeturnedoffatleastoncedailyforcleaning.Iflowerqualityfuelsareused,additionaldailyshutdownsmayberequiredforcleaning.
3)HI:SimilartotheLOmode,theunitwillruncontinu-ouslyatthehighburnrateuntiltheunithasrunoutoffuelorthedialisturnedtoadifferentsetting.Tooper-ateinthismode,turnthedialclockwiseuntilitstops.Thedialindicatorwillpointtothelargeflame.WheninthissettingtheLEDwillbeamberincolorandcontinu-ouslyon.Followthedailycleaningrecommendationswhenoperatinginthismode.Iflowerqualityfuelsareused,additionaldailyshutdownsmayberequiredforcleaning.
4)COMFORTLEVEL:ToburnintheComfortLevelmode,turnthedialcontrolclockwisetothedesiredcomfortlevel.Whenoperatingintheautomaticmode,theunitchangestheburnsettingbasedonthediffer-encebetweentheroomtemperatureandthedesiredsetpoint.Inotherwords,theunitwillburnonHighifthedifferencebetweenthedesiredandroomtemperatureisgreaterthan8degreesFahrenheit.Astheroomheatsupandthegapcloses,theunitwillautomaticallyreducetheburnrate.Whentheroomtemperatureisclosetothesetpointthelightwillstopflashingstaysolidgreen.atthistimethestovewillbeburningonthelowestburnrate.Whenthedesiredtemperatureisachievedtheunitwillshutdown.Astheroomcools,theunitwillrestartautomatically.WhenburninginthismodetheLEDwillbeblinkinggreen.Thenumberofgreenflashescorre-spondstothecurrentsetting.
B. Filling the HopperSlowlyopenthehopperlidbyliftingthehandle.Themediumandlargeunitshavealockinglatchthatwillengagewhenthehopperlidisfullyopened.Thehopperlidforthecabinetwillopenpastninetydegreesandstayopenautomatically.Fillthehopperwithfuel.FOR USE WITH ONLY WOOD PELLET FUEL.Slowlyclosethehopperlid.Seefigurebelowforreleasingthelatch.NOTE:Theunitwillnotfeedwiththehopperlidopen.Ifleftopen,thefirewillgoout.
Push Bottom of Latch Inward to Release
C. Priming the Feed TubeOnlyifthehopperisbeingfilledforthefirsttimeortheunithadpreviouslyrunoutofpellets,thefeedtubemayneedtobeprimed.Todothis,turnthedialcontrolfromtheOFFpositiontotheHIpositiontwotimes.Thiswillrunthefeedmotorcontinuouslyfortwominuteswithoutturningtheigniteron.Whentheaugerisrunningcontinuously,theLEDwillbeacontinuousgreencolor.Thesystemwillruntheaugerfor2minutes.Whenpelletsstarttodropintothefirepot,thefeedtubeisprimed;turnthedialcontroltothedesiredpositionandthestovewillbeginitsignitionsequence(ThegreenLEDwillflashrapidly).
CONFIDENTIAL PROPERTY OF HEARTH & HOME TECHNOLOGIES INC.
PART NAME:
DRAWN BY: SCALE: MATERIAL:
SHEET: PART NUMBER: REV:THIS PRINT IS CHECKED AND CONTROLLED BY THE ENGINEERING DEPARTMENTS OF HEARTH & HOME TECHNOLOGIES INC.ECO # DATE BYREV
UNLESS OTHERWISE SPECIFIED DIMS ARE INCHES[MM] & : TOLERANCES ARE: (2) PLACE DEC : ± 0.03 (3) PLACE DEC: ± 0.005 ANGLE: ± 2° FRACTION: ± 1/16OUTSIDE MATERIAL. NORMAL DIM & INSIDE MATERIAL. OUTSIDE APEX INSIDE APEX - DIMS ENCLOSED BY AN OVAL ARE CRITICAL DIMENSIONS
REVISIONS
ITEM PART NUMBER PART NAME QTY
02 RELEASE FOR TOOLING 72901 04/29/13 MCW
LABEL CONTROL PANELMCW 1:1 SEE NOTE
1 OF 1 7083-167 02
NOTE:1. MATERIAL: MYLAR2. ADHESIVE: 3M #468 PERMANENT ACRYLIC3. TEMPERATURE RATING: INK @ 325°F
TOOLING
3.75
2.81 4X R0.13
2
1
43
56
7
8
9
10LO
OFF HI
0-1
-2-3
-4
+1 +2+3
+4
ON
AUTO
ALARM
CONFIDENTIAL PROPERTY OF HEARTH & HOME TECHNOLOGIES INC.
PART NAME:
DRAWN BY: SCALE: MATERIAL:
SHEET: PART NUMBER: REV:THIS PRINT IS CHECKED AND CONTROLLED BY THE ENGINEERING DEPARTMENTS OF HEARTH & HOME TECHNOLOGIES INC.ECO # DATE BYREV
UNLESS OTHERWISE SPECIFIED DIMS ARE INCHES[MM] & : TOLERANCES ARE: (2) PLACE DEC : ± 0.03 (3) PLACE DEC: ± 0.005 ANGLE: ± 2° FRACTION: ± 1/16OUTSIDE MATERIAL. NORMAL DIM & INSIDE MATERIAL. OUTSIDE APEX INSIDE APEX - DIMS ENCLOSED BY AN OVAL ARE CRITICAL DIMENSIONS
REVISIONS
ITEM PART NUMBER PART NAME QTY
A RELEASED 72906 06/20/13 MCW
LABEL OPERATION AND MAINTENANCEMCW NTS SEE NOTE
1 OF 1 7083-168 A
NOTE:1. MATERIAL: NON-ANODIZED ALUMINUM 0.020 THICK2. BACKGROUND: BLACK3. COPY: SILVER4. ADHESIVE: 3M #468 PERMANENT ACRYLIC5. TEMPERATURE RATING: -50°F TO 350°F
RELEASED - ---- ----- -
6.75
11.75 4X R0.13
2XBroken Exhaust Probe
Sonde d'échappement casséSonda de escape roto
1XEmpty Hopper
trémie videtolva vacía OFF
3XBroken Ambient Probe
Cassé la sonde ambianteSonda ambiente roto
4XFailed Ignition
allumage échouéde encendido no OFF
8XHigh Exhaust Temperature
Température d'échappement hauteAlta temperatura de escape
TroubleshootingDépannage / Solución de problemas
Reset From Error1. Determine error from above table.2. Correct error condition. (see Owner’s Manual for additional information.)3. Turn dial control to OFF position, wait 10 seconds.4. Follow STARTING instructions.
Réinitialisation des erreurs1. Déterminer l'erreur de tableau ci-dessus.2. Condition d'erreur correct. (voir le manuel du propriétaire pour plus
d'informations.)3. Tourner le cadran de commande en position OFF, attendez 10 secondes.4. Suivez les instructions de démarrage.
Restablecer de error1. Determinar el error de la tabla anterior.2. Condición de error correcto. (consulte el Manual del Propietario para
obtener información adicional.)3. Gire el dial de control en la posición OFF, espere 10 segundos.4. Siga las instrucciones de arranque.
Customer Service / Service Clients / Servicio al Cliente877-427-3316 www.pelprostoves.com
Daily / Quotidien / Todos los días 1 Bag / 1 Sac / 1 Bolsa
Empty Firepot / Creuset Vide / Brasero De Fuego Vacía Clean Firepot / Clean Creuset / Limpieza Brasero De Fuego
Weekly / Hebdomandair / Semanalmente 5 Bags / 5 Sacs / 5 Bolsas
Clean Holes / Nettoyer Les Trous / Limpie Los Ori�cios Remove Ash / Retirez Les Cendres / Quitar Las Cenizas
Monthly / Mensuel / Mensualmente 25 Bags / 25 Sacs / 25 Bolsas
1
23
Remove / Supprimer / Quitar Vacuum / Vide / Vacío
Maintenance / Entretien / Mantenimiento
7083-168
Operation / Opération / Operación
Automatic Mode *mode AutomatiqueModo Automático
Priming Fuelcarburant d'amorçage
cebado de combustible
Minimum / Maximum **minimale / maximale
mínimo / máximo
Starting1. Turn dial control to OFF position.2. Fill hopper with pellets.3. Turn dial control to desired setting.
Départ1. Tourner le cadran de commande en
position OFF.2. Remplir la trémie avec des granulés.3. Tourner le cadran de commande au réglage
désiré.A partir
1. Gire el dial de control en la posición OFF.2. Llene la tolva con perdigones.3. Gire el dial de control hasta la posición deseada.
Stopping1. Turn dial control to OFF position.2. Allow unit to cool before performing any maintenance.
Arrêt1. Tourner le cadran de commande en position OFF.2. Laissez refroidir avant d'e�ectuer toute opération de maintenance.
Parada1. Gire el dial de control en la posición OFF.2. Deje enfriar la unidad antes de realizar cualquier trabajo de mantenimiento.
* The appliance will automatically maintain the desired comfort level and shut down when level has been achieved.
L'appareil passera automatiquement maintenir le niveau de confort désiré et arrêter lorsque le niveau a été atteint.
El aparato mantendrá automáticamente el nivel de confort deseado y se cerrará cuando el nivel se ha logrado.
** The appliance will run continuously until switched to OFF or AUTOMATIC mode. L'appareil fonctionne de façon continue jusqu'à ce que passe en mode OFF ou AUTOMATIQUE. El aparato funciona continuamente hasta que cambia al modo OFF o AUTOMÁTICO.
2
1
43
56
7
8
9
10LO
OFF HI
About65•F About82•F
3 General Operating Information
![Page 8: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/8.jpg)
7083-171B • July 23, 2013 (877) 427- 33168
D. Firepot Burn DownAfeatureofthesepelletstovesisthefirepotburndowncycle.Thefrequencyofthecycleisonceeveryhourtheunitisburning.Duringthisevent,thefeedisreducedtothelowestsettingandtheexhaustblowerrampsuptothehighestsetting.Thepurposeoftheburndowncycleistohelpremovedebrisfromthefirepotandhelptheunitburnasefficientaspossible.Thecyclelasts99seconds.Pleasebeawarethattheburndowndoesnotreplacedailycleaningactivitiesbutmakesthemeasier.
E. ShutdownToshuttheappliancedown,turnthedialcontrolcounterclockwisetotheOFFposition.Duringtheshutdownpro-cess,theLEDwillflashgreenrapidlyjustliketheignitionsequence.Thefirepotburndowncyclewillbeginbutwith-outthefeedmotorrunning.Thefeedwillbeterminatedduringthisshutdownprocess.Theexhaustandconvectionblowerswillremainonduringtheshutdownprocessuntiltheexhausthascooled.Ifmaintenanceordailycleaningisgoingtobeconductedimmediatelyfollowingashutdown,pleaseusecautionascomponentsespeciallythoseinsidethefireboxmaystillbehot.Please note that if the dial control is turned to the off position and back on even if by mistake, the unit will go through the shutdown sequence.
F. Starting Your First Fire
1) Turn the dial control to “OFF”.2) Make sure the firepot is clean, inplace, and free of debris. 3) Plug the unit into the wall and fill the hopper with wood pellets. Shut the hopper lid. 4) Turn the dial control to the desired burn setting.
Theunitwillgointotheignitionsequencefollowedbystartup(ThegreenLEDwillflashrapidly).Theigni-tionsequenceinvolvestheexhaustblowerturningon,theigniterturningon,andthefeedmotorrunningintwostages.Thefirststageinvolvesthefeedmotorrunningcontinuouslyforaboutaminutetopreloadpelletsintothefirepot.Followingthepreloadandadelay,thefeedmotorwillbegincyclingonandoff.Whenthepelletsarewarmingupandonthevergeofigniting,itisnotuncommonforthefireboxtofillwithsmoke.Onceignitionactuallyhappens,thesmokeshouldevacuatequickly.Duringthisstageaswellasanypartduringtheburnprocess,thefrontdoorshouldnotbeopened.Thiscyclecontinuesuntiltheunitsensesignitionbyariseintheexhausttemperatureortheunittimesout.Followingtheignitioncycletheunitbeginstofeedadditionalpelletsgraduallyforafewminutestobuildupthefire.Thisisimportanttohaveacontrolledstartuptokeeptheunitinbalance.
G. Fire CharacteristicsTheoverallheightoftheflamewillvarythroughouttheburnforacoupleofreasons.Firstisthattheflamewillvarybasedontypeoffuelorevenbatchoffuel.Secondly,theunitadjuststheburnrateaccordingtothehowfarawaytheroomtemperatureisfromthesettemperature.Thisshouldnotcausealarm.Thethirdcharacteristicthataffectsthefirerelatestogeneralmaintenanceandclean-ing.Infrequentorpoorgeneralmaintenancewillresultispoorerperformance.Indicatorsoftheneedforadditionalmaintenanceactivitiesincludealazyflame,blacksootedglass,pelletsnotigniting,orpelletsfallingtothesideofthefirepot.Seethemaintenancesectionforadditionalinfor-mation.
Odorsandvaporsreleasedduringinitialoperation.• Curingofhightemperaturepaint.• Openwindowsforaircirculation.
Odorsmaybeirritatingtosensitiveindividuals.
CAUTION
C. Priming the Feed Tube (Cont’d)AFIREPOTTHATISMORETHANHALFFULLISOVER-FILLED.DONOTOVERFILLFIREPOTFORIGNITION.Ifthereareexcessivepelletsinthefirepotthestartswillbeextremelysmokeyandcauseanunstableignitionthatincludesbutnotlimitedtorumblingandwhistling.
MAXIMUMPELLET LEVEL
![Page 9: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/9.jpg)
www.pelprostoves.com 7083-171B•July23,2013 9
H. Your Pellet Appliance - General Operating Parts
WARNING
Hot glass will cause burns.• DO NOTtouchglassuntilitiscooled• NEVERallowchildrentotouchglass• Keepchildrenaway• CAREFULLYSUPERVISEchildreninsameroomasappliance.• Alertchildrenandadultstohazardsofhightemperatures.High temperatures may ignite clothing or other flammable materials.• Keepclothing,furniture,draperiesandotherflammablematerialsaway.
HOT SURFACES!GlassandothersurfacesarehotduringoperationANDcooldown.
NOTICE:Ifyouexpectthatchildrenmaycomeintocontactwiththisappliance,werecom-mendabarriersuchasadecorativescreen.Seeyourretailerforsuggestions.
2
1
43
56
7
8
9
10LO
OFF HI
0-1
-2-3
-4
+1 +2+3
+4
ON
AUTO
AL
ARM
Baffles (3)
Firepot
Drop Tube
Hopper Lid Switch Dial Control
![Page 10: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/10.jpg)
7083-171B • July 23, 2013 (877) 427- 331610
LED Color
Number of Flashes between
pauses
Description Notes
Green SteadyONwhileprimingfeedtube(maxtime2min-
utes)
FeedMotorisrunningcontinuously.(Thisprimesthefeedtube).
Whenprimingthefeedsystemandfillingthefirepot,DO NOT OVERFILL FIREPOT FOR IGNITION.Theunitwillautomaticallygointostartupfollowingtheprimefunction.
Green SteadyONwhileburning
Roomtemperatureisclosetosetpointandburningonlowestburntrate.
Green 1x Unitisoffandready. Tostartappliance,followstartupsequence.
Green 3x Applianceisinthestartup/ignitionsequenceorinshutdown.
Duringshutdown,theblowerswillshutoffwhentheexhausttemperaturehascooled.
Green Varies Whenintheautomaticmode,thenumberofflashesbetweenpausesindicatestheburnrate(1forlowupto5forhigh).
Adjustthedialcontroltochangethedesiredroomtemperature.
Amber SteadyON Applianceissetandrunningateithertheminimumormaximumpowerlevels.
Theunitwillshutoffonlywhenthehopperrunsoutoffuel,theuserchangesthedialcontroltoadifferentstate,ortheunitsensesanerror.
Red 1x EmptyHopperAlarm Thisalarmiscausedbythefiregoingoutfromlackoffuel.Seetroubleshootingsec-tionformoreinformation.
Red 2x ExhaustProbeAlarm Failedcomponenterror.Seetroubleshoot-ingsectionformoreinformation.
Red 3x AmbientProbeAlarm Failedcomponenterror.Seetroubleshoot-ingsectionformoreinformation.
Red 4x MissedIgnition Thereareatotalof2triesperignitionsequence.Ifafter2triesthereisnoriseinexhausttemperaturethiserrorwilloccur.Seethetroubleshootingsectionforaddi-tionalinformationandcorrection.
Red 8x ExhaustGasOverTemperatureAlarm Theexhausttemperatureexceedtheallow-ablelimit.Seethetroubleshootingsectionformoreinformationandcorrection.
I. LED Color Coding Chart and Explanation
WARNINGFireRiskDoNOToperateappliance:• Withappliancedooropen.• Firepotflooropen.
DoNOTstorefuel:• Closerthanrequiredclearancestocom-
bustiblestoappliance• Withinspacerequiredforloadingorash
removal.
![Page 11: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/11.jpg)
www.pelprostoves.com 7083-171B•July23,2013 11
N. Trim Adjustment
NOTE:Therightsidepanelmustberemovedtomaketrimadjustmentswiththedialcontrol
Toseeavisual,gotopage18&referencesidepanelreplacementpart
Thesmalldiallocatedbelowthemaindialcontrolisusedtoadjusttheamountofcombustionairforthefire.Youmayneedtoadjustthecombustionairtothefirefor: Elevation Venting/InstallationConfigurations FuelQualityIfyourfireistoolarge,lazy,orproducingblacksoot,youneedMOREair.Toincreasetheamountofcombus-tionair,rotatecounterclockwiseonelevelatatimeandallow15minutesforstabilizationpriortomakinganotheradjustment.Ifyourfireistoosmallandsometimesgoesoutwhentherearepelletsinthehopper,youmayhavetoomuchair(toolean).Todecreasetheamountofcombustionair,rotateclockwiseonelevelatatimeandallow15minutesforstabilizationpriortomakinganotheradjustment.
J. Ignition Cycles
1. Atthebeginningofeachignitioncycle,itisnormaltoseesomesmokeinthefirebox.Thesmokewillstoponcethefirestarts.
2. The convectionblowerwill automatically turn onafteryourappliancehasbeenburningforapproximately10minutes.Thisblowertransfersheatfromyourapplianceintotheroom,andwillcontinue to runevenafter theunithasshutdown.Itwillturnoffaftertheexhausttemperaturehascooled.
3. Occasionallytheappliancemayrunoutoffuelandshutitselfdown.Whenthishappenstheemptyhopperalarmwillbetriggered.
WARNING! RISK OF FIRE! Keepcombustiblematerials,gasolineandotherflammablevaporsandliquidsclearofappliance.• DoNOTstoreflammablematerialsintheappliance’s
vicinity.• DoNOTusegasoline, lanternfuel,kerosene,charcoal
lighterfluidorsimilarliquidstostartor“freshenup”afireinthisheater.
Keepallsuchliquidswellawayfromtheheaterwhileitisinuseascombustiblematerialsmayignite.
M. Clear SpaceWARNING! RISK OF FIRE! DoNOTplacecombustibleobjectsinfrontortothesidesoftheappliance.Hightem-peraturesmayigniteclothing,furnitureordraperies.
NOTICE: Clearancesmayonlybereducedbymeansap-provedbytheregulatoryauthorityhavingjurisdiction.
Mantel: Avoid placing candles and other heat-sensitiveobjects on mantel or hearth. Heat may damage theseobjects.
K. Running in Minimum or Maximum
WhenthedialcontrolissettorunontheLOorHIsetting,theappliancewillcontinuetorunwithoutregardtotheactualtemperatureintheroom.Theappliancewillshutoffonlyifthedialcontrolissettoadifferentsettingorthereisanerrorsuchasanemptyhopper.
WhenrunningonLOorHIitisimportanttofollowthedailycleaningactivitiesespeciallycleaningthefirepot.Failuretodosowillreducetheperformanceoftheappliance.
L. Running in the Comfort Level Mode
Whenthedialcontrolissettorunintheautomaticmodetheunitwilladjusttheactualburnratebasedonthedifferencebetweentheroomtemperatureassensedbytheprobelocatedintherearoftheunitandthedesiredcomfortlevelassetonthedialcontrol.
Thecomfortlevelrangeisfrom65degreesFahrenheitto82degreesFahrenheit.
Oncethedesiredcomfortlevelisachievedtheappliancewillautomaticallyshutdownandturnoff.Whenthetemperatureintheroomdrops3degreesbelowthedesiredcomfortlevel,theappliancewillautomaticallyrestart.
CONFIDENTIAL PROPERTY OF HEARTH & HOME TECHNOLOGIES INC.
PART NAME:
DRAWN BY: SCALE: MATERIAL:
SHEET: PART NUMBER: REV:THIS PRINT IS CHECKED AND CONTROLLED BY THE ENGINEERING DEPARTMENTS OF HEARTH & HOME TECHNOLOGIES INC.ECO # DATE BYREV
UNLESS OTHERWISE SPECIFIED DIMS ARE INCHES[MM] & : TOLERANCES ARE: (2) PLACE DEC : ± 0.03 (3) PLACE DEC: ± 0.005 ANGLE: ± 2° FRACTION: ± 1/16OUTSIDE MATERIAL. NORMAL DIM & INSIDE MATERIAL. OUTSIDE APEX INSIDE APEX - DIMS ENCLOSED BY AN OVAL ARE CRITICAL DIMENSIONS
REVISIONS
ITEM PART NUMBER PART NAME QTY
A RELEASED 72906 06/20/13 MCW
LABEL OPERATION AND MAINTENANCEMCW NTS SEE NOTE
1 OF 1 7083-168 A
NOTE:1. MATERIAL: NON-ANODIZED ALUMINUM 0.020 THICK2. BACKGROUND: BLACK3. COPY: SILVER4. ADHESIVE: 3M #468 PERMANENT ACRYLIC5. TEMPERATURE RATING: -50°F TO 350°F
RELEASED - ---- ----- -
6.75
11.75 4X R0.13
2XBroken Exhaust Probe
Sonde d'échappement casséSonda de escape roto
1XEmpty Hopper
trémie videtolva vacía OFF
3XBroken Ambient Probe
Cassé la sonde ambianteSonda ambiente roto
4XFailed Ignition
allumage échouéde encendido no OFF
8XHigh Exhaust Temperature
Température d'échappement hauteAlta temperatura de escape
TroubleshootingDépannage / Solución de problemas
Reset From Error1. Determine error from above table.2. Correct error condition. (see Owner’s Manual for additional information.)3. Turn dial control to OFF position, wait 10 seconds.4. Follow STARTING instructions.
Réinitialisation des erreurs1. Déterminer l'erreur de tableau ci-dessus.2. Condition d'erreur correct. (voir le manuel du propriétaire pour plus
d'informations.)3. Tourner le cadran de commande en position OFF, attendez 10 secondes.4. Suivez les instructions de démarrage.
Restablecer de error1. Determinar el error de la tabla anterior.2. Condición de error correcto. (consulte el Manual del Propietario para
obtener información adicional.)3. Gire el dial de control en la posición OFF, espere 10 segundos.4. Siga las instrucciones de arranque.
Customer Service / Service Clients / Servicio al Cliente877-427-3316 www.pelprostoves.com
Daily / Quotidien / Todos los días 1 Bag / 1 Sac / 1 Bolsa
Empty Firepot / Creuset Vide / Brasero De Fuego Vacía Clean Firepot / Clean Creuset / Limpieza Brasero De Fuego
Weekly / Hebdomandair / Semanalmente 5 Bags / 5 Sacs / 5 Bolsas
Clean Holes / Nettoyer Les Trous / Limpie Los Ori�cios Remove Ash / Retirez Les Cendres / Quitar Las Cenizas
Monthly / Mensuel / Mensualmente 25 Bags / 25 Sacs / 25 Bolsas
1
23
Remove / Supprimer / Quitar Vacuum / Vide / Vacío
Maintenance / Entretien / Mantenimiento
7083-168
Operation / Opération / Operación
Automatic Mode *mode AutomatiqueModo Automático
Priming Fuelcarburant d'amorçage
cebado de combustible
Minimum / Maximum **minimale / maximale
mínimo / máximo
Starting1. Turn dial control to OFF position.2. Fill hopper with pellets.3. Turn dial control to desired setting.
Départ1. Tourner le cadran de commande en
position OFF.2. Remplir la trémie avec des granulés.3. Tourner le cadran de commande au réglage
désiré.A partir
1. Gire el dial de control en la posición OFF.2. Llene la tolva con perdigones.3. Gire el dial de control hasta la posición deseada.
Stopping1. Turn dial control to OFF position.2. Allow unit to cool before performing any maintenance.
Arrêt1. Tourner le cadran de commande en position OFF.2. Laissez refroidir avant d'e�ectuer toute opération de maintenance.
Parada1. Gire el dial de control en la posición OFF.2. Deje enfriar la unidad antes de realizar cualquier trabajo de mantenimiento.
* The appliance will automatically maintain the desired comfort level and shut down when level has been achieved.
L'appareil passera automatiquement maintenir le niveau de confort désiré et arrêter lorsque le niveau a été atteint.
El aparato mantendrá automáticamente el nivel de confort deseado y se cerrará cuando el nivel se ha logrado.
** The appliance will run continuously until switched to OFF or AUTOMATIC mode. L'appareil fonctionne de façon continue jusqu'à ce que passe en mode OFF ou AUTOMATIQUE. El aparato funciona continuamente hasta que cambia al modo OFF o AUTOMÁTICO.
2
1
43
56
7
8
9
10LO
OFF HI
![Page 12: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/12.jpg)
7083-171B • July 23, 2013 (877) 427- 331612
1. Types of Fuel
Thetypeoffuelyouareburningwilldictatehowoftenyouhavetocleanyourfirepot.Ifthefuelyouareburninghasahighdirtorashcontent,itmaybenecessarytocleanthefirepotmorethanonceaday.Poorqualityfuelwillcauseclinkerstoforminthefirepot.Aclinkerisformedwhendirt,ashoranon-burnablesubstanceisheatedto2000°F(1093°C)andbecomesglass-like.SeesectionDfollowingformoredetailsonfuelswithhighashcontent.
Shock and Smoke Hazard• TurndialcontroltoOFF,letappliancecomplete-lycoolandexhaustblowermustbeoff.Nowyoucanunplugappliancebeforeservicing.
• Smokespillageintoroomcanoccurifapplianceisnotcoolbeforeunplugging.
• Riskofshockifappliancenotunpluggedbeforeservicingappliance.
CAUTION
Cleaning or Inspection Frequency Daily Weekly Monthly YearlyFirepot Every3bagsoffuel OR XAshRemovalfromFirebox Every5bagsoffuelormore
frequentlydependingonashbuild-up
OR X
Glass Whenclearviewoffirepotbecomesobscure OR X
Hopper Every25bagsoffuel OR XExhaustPath,DropTubeandBehindBaffles
Every25bagsormorefre-quentlydependingonashbuild-up
OR X
DoorHandle&GasketInspection Priortoheatingseason OR XBlower,Convection Every25bagsormorefre-
quentlydependingonoperat-ingenvironment.
OR X
Blower,Exhaust Morefrequentlydependingonthefueltype OR X
Firebox-PrepareforNon-BurnSeason Atendofheatingseason OR XVentingSystem Every3tonsormorefre-
quentlydependingonthefueltype
OR X
B. Quick Reference Maintenance Chart
Follow the detailed instructions found in this section for each step listed as referenced in the chart below.
NOTICE: Thesearerecommendations.Cleanmorefrequentlyifyouencounterheavybuild-upofashattherecommendedintervaloryouseesootcomingfromthevent.Not properly cleaning your appliance on a regular basis will void your warranty.
A. Proper Shutdown Procedure C. General Maintenance
4 Maintaining & Servicing the Appliance
![Page 13: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/13.jpg)
www.pelprostoves.com 7083-171B•July23,2013 13
2. Cleaning Firepot with the Firepot Clean-Out Tool;• Frequency:Dailyormoreoftenasneeded• By:Homeowner
3. Ash Removal from Firebox• Frequency:Weeklyormorefrequentlydependingon
ashbuild-up.• By:Homeowner
a.Theappliancemustbeincompleteshutdownandcoolandtheexhaustbloweroff.Ifyouarejustcleaningthefirepot,thereisnoneedtounplugtheappliance.
b.Open the frontdoorof theapplianceand liftout thefirepot. Use the firepot cleaning tool to break updepositsinsidethefirepotanddisposeinanapprovedcontainer.Dependingonthequalityoffuelused,thefrontofthefirepotmayneedtoberemovedforbetteraccessforcleaning.
c.Usethenarrowendofthefirepotcleaningtooltocleantheholes.
d.Withthefirepotoutcleantheareabelowthefirepot.e.Reassemblethefirepotandplacebackinsidethefirepot
riser.Makesurethefirepotisinthecorrectdirectionwith theslanted lip in therear. Failure to install thefirepotcorrectlymayresultinmissedignitions.
a.Theremustnotbeanyhotashesinthefireboxduringcleaningsoallowtheappliancetocompletelycool.Thefireboxashshouldberemovedeverytimetheexhaustpathiscleaned.Frequentcleaningoftheashinthefireboxwillhelpslowdownthebuild-upofashintheexhaustblowerandventsystem.
b.Vacuumoutthefireboxthoroughlyonbothsidesofthefireboxandthefloorandceiling.Remembertoplacetheashanddebris into ametal or non-combustiblecontainer.See Disposal of Ashes.
DisposalofAshes
WARNING
• Ashesshouldbeplacedinmetalcontainerwithtightfittinglid.
• Ashesshouldberetainedinclosedcontaineruntilallcindershavethoroughlycooled.
4. Disposal of Ashes• Frequency:Asneeded• By:Homeowner
Ashes should be placed in ametal containerwith atight-fitting lid. Theclosedcontainerofashesshouldbeplacedonanon-combustiblefloororontheground,wellawayfromallcombustiblematerials,pendingfinaldisposal.Iftheashesaredisposedofbyburialinsoilorotherwiselocally dispersed, they should be retained in theclosedcontaineruntilallcindershavebeenthoroughlycooled.
![Page 14: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/14.jpg)
7083-171B • July 23, 2013 (877) 427- 331614
8. Cleaning the Exhaust Path, Baffles & Drop Tube• Frequency:Monthlyorevery25bagsormorefre-
quentlydependingonashbuild-up.• By:Homeowner a.Appliancemustbecompletelycool. b. Openthedoorandremovethecenterbafflefirstand
thentherightandleftbaffles.Thoroughlyvacuumtheexhaustpathanddroptubeandcontinuethroughouttherestof thefirebox. Alsovacuumthe frontandbackofthebaffles.
c. Using a small brush, brush the innerwalls of theexhaustoutletfromtheaccessholeinsidethefirebox.Theaccessholewillbevisiblefollowingtheremovaloftheleftsidebaffle.Afterlooseningupdebrisontheinnerwallsoftheoutlet,vacuumout.This is important as the exhaust temperature probe is attached to the right side of the outlet. If this is not maintained on a regular basis, the appliance will experience nuisance shut downs and/or missed ignitions.
d. Replacetherightandleftbafflesandthenthecenterbaffleandcloseandlatchthedoor.
7. Cleaning the Hopper• Frequency:Monthlyorafterburning25bagsoffuel• By:Homeowner
After burning approximately 25 bags of fuel you willneedtocleanthehoppertopreventsawdustbuild-up.A combination of sawdust and pellets on the bottomendoftheaugerreducestheamountoffuelsupplytothefirepot.Thiscanresultinnuisanceshutdownsandmis-starts.
a. The appliance must be in complete shutdown.Allowtheappliancetocompletelyrunoutofpelletsandcooldown.
b. Emptythehopperofanyremainingpellets. c. Vacuumthehopperandfeedtube.Toaccessthefeedtuberemovethefourscrewsfromtheaugercoverlocatedinsideofthehopper.
6. Cleaning the Glass
• Frequency:Whenclearviewofthefirepotbecomesobscure
• By:Homeowner a.Appliancemustbecompletelycoolbeforecleaning
glass. b. Vacuumflyashfromglassanddoorrope. c.Useadamppapertoweloranynon-abrasiveglass
cleaner.Wipeoffwithdrytowel.
Handleglassassemblywithcare.
When cleaning glass:• Avoidstriking,scratchingor
slammingglass.• DoNOTcleanglasswhenhot.
CAUTION
• DoNOTuseabrasivecleaners.• Refertomaintenanceinstructions.• DoNOToperatewithglasscracked,brokenorscratched.
9. Door Handle Inspection• Frequency:Monthlyorpriortoheatingseason• By:HomeownerThe gasketing between the glass and firebox should beinspectedperiodicallytomakesurethereisagoodseal.
NOTE: Pelpro recommends using a heavy duty vacuum cleaner specifically designed for solid fuel appli-ance cleaning.
1
23
![Page 15: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/15.jpg)
www.pelprostoves.com 7083-171B•July23,2013 15
13. Soot and Fly Ash: Formation & Need for Removal in Exhaust Venting System.
• Frequency:Yearlyormorefrequentlydependingonashbuild-up.
• By:QualifiedServiceTechnician/Homeowner
Besuretheapplianceisallowedtocool,hasbeenunpluggedandtheexhaustblowerisoff.Theproductsofcombustionwillcontainsmallparticlesofflyash.Theflyashwillcollectintheexhaustventingsystemandrestricttheflowofthefluegases.Atstart-upifthereisincompletecombustion,orifthereisashutdownorincorrectoperationoftheapplianceitwillleadtosomesootformation.Thiswillcollectintheexhaustvent-ingsystem.Theventing(chimney)systemmayneedtobecleanedatleastonceayearormoreoftendependinguponthequal-ityofyourfuelorifthereareanyhorizontalpipesections.Ashwillbuildupmorequicklyinthehorizontalsectionsandelbows.
11. Cleaning Exhaust Blower - Requires No Lubrication
• Frequency:Yearlyormorefrequentlydependingonashbuild-up
• By:HomeownerorQualifiedServiceTechnician
10. Cleaning Convection Blower - Requires No Lubrication
• Frequency:MonthlydependingonDust/Dirtbuild-up• By:HomeownerorQualifiedServiceTechnician
12. Preparing Firebox for Non-Burn Season• Frequency:Yearly• By:Homeowner
a.Besuretheapplianceisallowedtocool,hasbeenunpluggedandtheexhaustblowerisoff.
b.Removeallashfromthefireboxandvacuumthoroughly. c. Paintallexposedsteel,includingcast-iron.
• Purchasehightemperaturepaintfromyourlocalretailer.
• Mustuseahigh-temperaturepaintmadespecifi-callyforheatingappliances.
a.Besure theappliance isallowed tocool,hasbeenunpluggedandtheexhaustblowerisoff.
b.Removetheleftsidepanel. c.Remove thesixscrewsholding theexhaustblower
motortothehousingandremovethemotor.Usingcautionastonotdamagethegasketwhenremovingtheblower. Ifdamageoccurs, installanewgasketavailableasareplacementpart.
d.Vacuumtheblower’simpellers.Usecarenottobendordamagetheblowerfins.
e.Usingabrushorvacuumattachment,cleantheinsideoftheexhaustoutlet.
f.Reattachthemotor.Makesurethewiresareattachedtotheterminalsontheblower.
a.Besuretheapplianceisallowedtocoolandhasbeenunplugged.
b.Removetherightsidepanel. c.Sweeporvacuumoutanybuild-upontheimpellers.
Useabrushorcompressedairtoloosendirtifneeded.Avoiddamagingtheimpellers.
![Page 16: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/16.jpg)
7083-171B • July 23, 2013 (877) 427- 331616
D. High Ash Fuel Content Maintenance• Frequency:Asneeded• By:Homeowner
Poorqualitypelletfuel,lackofmaintenance,orifthesmalldialcontrolissettoalessthanoptimumsetting,poorcom-bustionconditionsthatmakethefirepotfillquicklywithashesandclinkers.Thisconditionmakestheappliancesusceptibletooverfillingthefirepotwithpelletswhichmay result insmoking,soot-ingandpossiblehopperfires.Thefigurebelowshowsanexamplewherethefirepotoverfills,pelletsbackupintothefeedtubeandashhasaccumulatedinthefirebox.Aninefficientandnon-economicalmethodofburningoffuelcausedbypoorqualitypelletfuelisshownbelow. If the ash buildup exceeds the half way point in the firepotIMMEDIATE ATTENTION AND CLEANING IS REQUIRED.
Incorrect Flame HeightTall, Lazy Flame Orange in Color
Pellets Back-up in Feed Tube
Ash build-up in Firebox
Firepot Overfills
![Page 17: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/17.jpg)
www.pelprostoves.com 7083-171B•July23,2013 17
E. Frequently Asked Questions
What causes my glass to become dirty?Iftheglasshaswhiteashbuildupitisnormalandtheglassshouldbecleaned.Ifitisablacksootbuildupairflowthrutheunitmayberestricted.Themostoftencauseisoverduemaintenanceandcleaning.See“MaintainingandServicingAppliance”intheowner’smanualand/ormakeadjustmentstothetrimcontrol.
How can I get more heat out of the appliance?Themostoftencauseofdiminishedheatoutputisoverduemaintenanceandcleaning.See“MaintainingandServicingAppliance”intheowner’smanual.
What should I do if I smell smoke or there is ash/soot coming from the appliance? Whiletherewillalwaysbesomesmokesmellfromwoodburningappliances(includingpellet)youshouldinvestigateallventingtomakesureitissealedprop-erly.Mostventingrequiressiliconetosealtheseams.Inadditionmosthomesarebuiltverytighttodayandwithexhaustsystemscancreatenegativepressureinthehome.See“NegativePressure”under“GettingStarted”intheowner’smanualifyouhavecheckedtheventingbutstillhavesmokecomingfromtheappli-ance.Forashorsootchecktheaboveandtheexhaustblowerhousingandseals. Why would my appliance run fine last winter but not start this fall? ItispossiblethatthestovewasnotproperlypreparedfortheNon-burnseason.See“Troubleshooting”intheowner’smanual.
Why would the metal on the inside of the appliance begin to flake? Therearesomepelletmillsthatgettheirrawmaterialsfromlumbermillsthatpurchaselogsthataretrans-portedinseawater.Thesepelletscanhaveahighersaltcontentandcausethemetalsintheunittocorrodeprematurelyanddeteriorate.Ifyouareseeinganycomponentsinsidethefireboxdeteriorateitisrecom-mendedtochangepelletbrandsimmediately.
Is there a place to lubricate the blowers to quiet them down? Themostoftencauseofnoisyblowersisfromtheimpellersbecomingdirtyovertime.See“GeneralMain-tenance&Cleaning”under“Maintaining&ServicingAppliance”intheowner’smanual.Noformoflubrica-tionshouldeverneedappliedtotheblowers.
What is the metal object with the bend in it for that came inside the plastic bag? Itisaclean-outtoolusedtohelpcleanthefirepotandremoveanyjamsintherareeventtheyoccurinthefeedtube.
Why is there a black residue building up on the outside of my home?Windcancausethistohappen.Iftheapplianceisoperatingcorrectlyverylittlesootshouldeverexittheterminationcap.Alsochecktobesuretheventingisinstalledpertheowner’smanualandlocalcodes.
Do I need an outside air kit? Outsideairisrequiredformobilehomeinstallsandinsomejurisdictions.Referto“Listing&CodeApprov-als”,“MobileHomeInstallation”and“ApplianceSet-up”owner’smanual.Alsorefertolocalbuildingcodes.
I am seeing sparks coming out of my pipe (termina-tion cap) outside is this safe? Thisisnormal.Aslongasclearancestocombustibleswerefollowedthisissafe. I have no power to anything. Does this unit have a circuit breaker or fuse or a reset button?Thisunithasoneserviceablefuseonthecontrolboardandaresetablesnapswitchmountedtothefeedtube.
Can I burn corn in my unit?NO,cornisnotanapprovedfuel.
Where is the serial # of my unit is located?Theserial#islocatedonthebackofthestove.
![Page 18: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/18.jpg)
7083-171B • July 23, 2013 (877) 427- 331618
A. Convection Blower Replacement 1. Turnthedialcontroltotheoffposition.Unplugthepower
totheunit.2. Theconvectionblowerislocatedintherearoftheunit.3. Using#2Phillips screwdriver, loosen the bolts on the
rearoftheunitholdingonthesidepanels.Youdonotneed to remove the screws. Remove side panels byliftingupandout.
4. Unplugthewiresfromtheconvectionblowermotorfromtherightsideoftheunit.
5. Removethetwoscrewsholdingtheconvectionblowerhousing to the sheet metal plenum. Using a slighttwistingmotion,rotatetheblowerbackanditwillrelease.
B. Exhaust Blower Replacement1. Turnthedialcontroltotheoffposition.Unplugthepower
totheunit.2. Removetheleftsidepanelbylooseningthetwoorthree
boltsintherearoftheunit.3. Disconnect2whitewiresfromthewhiteandbluewiresof
theexhaustblower.4. Removetheblowermotorattachedtoaremovableplate
on the exhaust blower. Depending on themodel, usea1/4 inchsocket,or1/4 inchNutDriveror#2PhillipsHeadscrewdrivertoloosenthe6screwsinthekeyholeshapedholesandrotatetheplate.Itisonlynecessarytoloosenscrews.
5. Removetheexhaustblowerandgasket.6. Check for degradation on the gasket and replace if
necessaryusingthegasketincludedinthekit.7. Re-installinreverseorder.
Loosen Screws, Do Not Remove
5 Replacement Parts
![Page 19: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/19.jpg)
www.pelprostoves.com 7083-171B•July23,2013 19
C. Snap Disc Replacement Power - Manual Reset1. Turnthedialcontroltotheoffposition.Unplugthepower
totheunit.2.Using#2Phillipsscrewdriver,loosentheboltsontherear
oftheunitholdingontheleftsidepanel.Youdonotneedtoremovethescrews.Removesidepanelsbyliftingupandout.
3.Locate the snap disk on the top side of the feed tubewhere itmeets thehopper. Disconnect thewire leadsfromthesnapdisk.
4.Usinga#1Phillipsscrewdriver,removetwo6-32fasten-ersretainingthesnapdiskontothesideofthefeedtube.
5.Using the same fasteners, attach the new snap disk.Attachthewireleads.
6.Restorepower.
D. Igniter Replacement 1. Turnthedialcontroltotheoffposition.Unplugthe
powertotheunit. 2. Unplugthewireleadstotheigniter. 3. Removethescrewinthesideoftheigniterchamber.
Pinchtheendsofthebrackettogetherandpulltheigniterstraightoutoftheigniterchamber.
4. Ifthereisdifficultyinremovingtheigniterfromthechamber,thechambercanberemovedfromtherearofthefireboxbyremovingthe1/4-20bolt.
5. Re-installthenewigniterintothechamberusingthebracket.
6. Inspect the igniter from the front of the unit byremoving the firepot and looking into the end ofthe chamber. MAKE SURE THE IGNITER ISCENTEREDINTHECHAMBER.
E. Baffle Removal & Replacement 1. Turnthedialcontroltotheoffposition.Makesurethe
unitiscool.2. Remove thecenterbafflefirstbyusing thehandleat
thetopofthebaffleandpullupandthentowardsyou.Thehooksonthebafflewillslideoutoftheslotsinthebracket.
3. Removetheleftbaffleandthentherightbafflebypullingupandthentowardsyou.Theleftandrightbaffleshavesimilarhooksandslots.
![Page 20: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/20.jpg)
7083-171B • July 23, 2013 (877) 427- 331620
• Glassis5mmthickhightemperatureheat-resistantceramicglass.
• DONOTREPLACEwithanyothermaterial.
• Alternatematerialmayshatterandcauseinjury.
WARNING
F. Glass Replacement1. Openthedoorfromtheappliancebyliftingdooroffofhinge
pinsandlayonaflatsurfacefacedown.2. UsingaPhillipsHeadscrewdriver,removethe3brackets
andsetaside.3. Removeoldglassandreplacewiththenewglass.4. Re-installthebracketsusingthesamescrews.
G. Control Board Replacement1. Turnthedialcontroltotheoffposition.Unplugthepower
totheunit.2. Unplugthewiresfromthecontrolboard.Theconnectors
are lockingconnectors. Pinchthereleasetaboneachconnectorandgentlytugandrockloose.
3. Pinchthe4plasticpinsfromtherearoftheunittoreleasethecontrolboardconnectors.
4. Installnewboardfollowingthestepsinreverse.
H. Fuse Replacement1. Turnthedialcontroltotheoffposition.Unplugthepower
totheunit.2. Pulltheplasticfuseholdercoveroffthecontrolboard.3. Replacefusewith5AMP120VACfuseonly.4. Replacethecoveronthefuseholderandrestartunit.
I. Feed Motor Replacement 1. Turnthedialcontroltotheoffpositionandunplugtheunit.
Removetherightsidepanelandfeedmotorcoverplateintherearoftheunit.
2. Unplugtheconnectorfromthefeedmotor.3. Usingpliers,removethecotterpin.4. Removethefeedmotorfromthefeedshaft.5. Reinstall thenew feedmotorbyaligning theclearance
holeinthefeedmotorshaftwiththeaugerspringshaft.6. Plugthefeedmotorleadsbackinandrestorepower.
J. Feed Spring Replacement 1.Emptythehopperofallpellets.thenfollowthestepsto
removethefeedmotorabove.2. Removethefourscrewsholdingthefeedmotorbracket
on.3. Slidetheaugerassemblyoutfromthebottomintherear
oftheunit.4. Inspectthebronzebearings,replaceifneeded.5. Install new spring assembly following reverse steps
includingreattachingthefeedmotor.
![Page 21: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/21.jpg)
www.pelprostoves.com 7083-171B•July23,2013 21
A. Design, Installation & Location Considerations
NOTICE: Checkbuildingcodespriortoinstallation.• InstallationMUSTcomplywithlocal,regional,stateand
nationalcodesandregulations.• Consult insurance carrier, local building inspector, fire
officialsorauthoritieshavingjurisdictionoverrestrictions,installationinspectionandpermits.
Sincepelletexhaustcancontainash,sootorsparks,youmustconsiderthelocationof:• Windows• AirIntakes• AirConditioner• Overhang,soffits,porchroofs,adjacentwalls• Landscaping,vegetationWhenlocatingventandventingtermination,ventaboverooflinewhenpossible.NOTICE: Locatingtheapplianceinalocationofconsiderableairmovement can cause intermittent smoke spillage fromappliance.Donotlocateappliancenear:• Frequentlyopendoors• Centralheatoutletsorreturns
B. DraftDraft isthepressuredifferenceneededtoventappliancessuccessfully.Whenanapplianceisdraftingsuccessfully,allcombustionbyproductsareexiting thehome through thechimney.
Considerationsforsuccessfuldraftinclude:• Preventingnegativepressure• LocationofapplianceandchimneyTomeasurethedraftornegativepressureonyourapplianceuseamagnahelic or a digital pressure gauge capable ofreading0-.25inchesofwatercolumn(W.C.).The appliance should be running on high for at least 15minutesforthetest.Withthestoverunningonhighyoushouldhaveanegativepressureequal toorgreater thanthenumbergiven in thechart. If you have a lower reading than you find on thechart,yourstovedoesnothaveadequatedrafttoburnthefuelproperly.
C. Negative PressureWARNING! Risk of Asphyxiation! Negativepressurecancausespillageofcombustionfumesandsoot.
Negativepressureresultsfromtheimbalanceofairavail-ablefortheappliancetooperateproperly.Itcanbestron-gestinlowerlevelsofthehouse.
Causesinclude:
• Exhaustfans(kitchen,bath,etc.)• Rangehoods• Combustionairrequirementsforfurnaces,waterheaters
andothercombustionappliances• Clothesdryers• Locationofreturn-airventstofurnaceorairconditioning• ImbalancesoftheHVACairhandlingsystem• Upperlevelairleakssuchas: - Recessedlighting - Attichatchoropenwindows - DuctleaksTominimizetheeffectsofnegativeairpressure:
• Installtheoutsideairkitwiththeintakefacingprevailingwindsduringtheheatingseason
• Ensureadequateoutdoorairforallcombustionappliancesandexhaustequipment
• Ensurefurnaceandairconditioningreturnventsarenotlocatedintheimmediatevicinityoftheappliance
• Avoid installing theapplianceneardoors,walkwaysorsmallisolatedspaces
• Recessedlightingshouldbea“sealedcan”design• Attichatchesweatherstrippedorsealed• Atticmountedductworkandairhandlerjointsandseams
tapedorsealed
NOTICE: Pelpro assumes no responsibility for theimproperperformanceofthechimneysystemcausedby:• Inadequatedraftduetoenvironmentalconditions• Downdrafts• Tightsealingconstructionofthestructure• Mechanicalexhaustingdevices
MODEL Minimum Vacuum Requirements
PP60 0.17inchesW.C.
B. Draft (Cont’d)Correctlowdraftorlowvacuumproblemsbydoingoneofthefollowing:• Thoroughlycleantheexhaustpathandventing.See
MaintenanceSection.• Inspectforwornorbrokengaskets.Repairanygaskets
suspectedofleaking,oradjustthetrim.
6 Getting Started
![Page 22: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/22.jpg)
7083-171B • July 23, 2013 (877) 427- 331622
Marginal Location:• Below peak
Location NOT recommended:• Not the highest point of the roof• Wind loading possible
Multi-level Roofs
Windward
Leeward
Recommended:Outside Air Intakeon windward side
NOT recommended:Outside Air Intakeon leeward side
Recommended Location:• Above peak
Recommended:• Insulated exterior chase
in cooler climates
Recommended Location:• Above peak• Inside heated space
Location NOT recommended:• Too close to tree• Below adjacent structure• Lower roof line• Avoid outside wall
Marginal Location:• Wind loading possible
D. Locating Your Appliance & Chimney Locationoftheapplianceandchimneywillaffectperformance.• Installthroughthewarmairspaceenclosedbythebuilding
envelope.Thishelps toproducemoredraft,especiallyduringlightinganddie-downofthefire.
• Penetratethehighestpartoftheroof.Thisminimizestheaffectsofwindloading.
• Locate termination cap away from trees, adjacentstructures,unevenrooflinesandotherobstructions.
• Minimizetheuseofchimneyoffsets.• Considertheappliancelocationrelativetofloorandceiling
andatticjoists.• Takeintoconsiderationtheterminationrequirements.
E. Inspect Appliance & Components• Removeapplianceandcomponentsfrompackaging
andinspectfordamage.• Reporttoyourdealeranypartsdamagedinshipment.• Read all the instructions before starting the installa-
tion. Follow these instructions carefully during the installation to ensure maximum safety and benefit.
ReciprocatingSawChannelLocksHammerPhillipsScrewdriverTapeMeasurePlumbLineLevelFramingMaterialNon-combustibleSealantMaterial
GlovesSafetyGlassesFramingSquareElectricDrill&Bits(1/4”)1/4”Self-TappingScrews
Mayalsoneed:VentSupportStrapsVentingPaint
Tools and building supplies normally required for installation, unless installing into an existing masonry fireplace:
F. Tools And Supplies Needed
Inspectapplianceandcomponentsfordamage.Damagedpartsmayimpairsafeoperation.
WARNING
• DoNOTinstalldamagedcomponents.• DoNOTinstallincompletecomponents.• DoNOTinstallsubstitutecomponents.
Reportdamagedpartstodealer.
![Page 23: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/23.jpg)
www.pelprostoves.com 7083-171B•July23,2013 23
Vertical Installations (Interior Flue)Straight Back Against Wall Inches MillimetersA BackWalltoAppliance 10 254B SideWalltoAppliance 13 330
Corner Installation Inches MillimetersC WallstoAppliance 3 76
B. Clearances to Combustibles (UL and ULC)
CAUTION• DONOTCONNECTTHISUNITTOACHIMNEYFLUE
SERVICINGANOTHERAPPLIANCE.
• DONOTCONNECTTOANYAIRDISTRIBUTIONDUCTORSYSTEM.
WARNING
Hot glass will cause burns.• Donottouchglassuntilitiscooled• NEVERallowchildrentotouchglass• Keepchildrenaway• CAREFULLYSUPERVISEchildreninsameroomas
fireplace.• Alertchildrenandadultstohazardsofhigh
temperatures.High temperatures may ignite clothing or other flammable materials.• Keepclothing,furniture,draperiesandotherflammable
materialsaway.
HOT SURFACES!
GlassandothersurfacesarehotduringoperationANDcooldown.
C
C
A
B
Horizontal Flue InstallationsStraight Back Against Wall Inches MillimetersA BackWalltoAppliance 2 51B SideWalltoAppliance 13 330
Turntopages25,26and27forsideviewsandmoredetailedimagesofclearancesandinstallationtypes.
A. Appliance Dimensions
3-1/2[89]
21-3/4 [552]
21-15/16[558]
MODEL: PP60
33[838]
21-3/4 [552]
12[305]
33[838]
4-1/8[104]
19-7/8 [504]
7 Dimensions and Clearances
![Page 24: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/24.jpg)
7083-171B • July 23, 2013 (877) 427- 331624
*C: Exception for Horizontal Installations:CANADA INSTALLATIONS:Anoncombustiblefloorpro-tectionsextendingbeneath thefluepipe isrequiredwithhorizontalventingorunderthetopventadapterwithverti-calinstallation.USA INSTALLATIONS:Anon-combustiblefloorprotectionextendingbeneaththefluepipeisrecommendedwithhori-zontalventingorunder the topventadapterwithverticalinstallation. A non combustible floor protector is required.
C. Hearth Pad Requirements (UL and ULC)Useanon-combustiblefloorprotector,extendingbeneathappliance and to the front, sides and rear as indicated.Measure frontdistance “M” from thesurfaceof theglassdoor.
Hearth Pad Requirements Inches
K Sides 2
L* Back 2
M Front 6
Hearth Pad Requirements Millimeters
K Sides 203
L* Back 51
M Front 152
USA Hearth Pad Requirements
Canada Hearth Pad Requirements
WARNING
If the information in these instruc-tions is not followed exactly, a fire may result causing property damage, personal injury, or death.
• Donotstoreorusegasolineorotherflam-mablevaporsandliquidsinthevicinityofthisoranyotherappliance.
• Donotoverfire-Ifheaterorchimneyconnectorglows,youareoverfiring.Overfiringwillvoidyourwarranty.
• Complywithallminimumclearancestocombustiblesasspecified.Failuretocomplymaycausehousefire.
Must extend 2 inches (51mm) beyond each side of pipe (shaded area)
L*
K
M
K
![Page 25: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/25.jpg)
www.pelprostoves.com 7083-171B•July23,2013 25
Do not terminate ventinanyenclosedorsemi-enclosedareasuchasacarport,garage,attic,crawlspace,underasundeckorporch,narrowwalkwayorcloselyfencedarea,oranylocationthatcanbuildupaconcentrationoffumessuchasastairwell,coveredbreezeway,etc.
CAUTIONA. Chimney and Exhaust Connection
1. Chimney & Connector: Use3or4 inch (76-102mm)diametertype"L"or"PL"ventingsystem.Itcanbeventedverticallyorhorizontally.
2. Mobile Home: ApprovedforallListedpelletvent.Ifusingthe3inch(76mm)verticalTopVentAdapterKitorthe3to6inch(76-152mm)TopVentOffsetAdapter,useListeddoublewallflueconnector.AnauthorizedOutsideAirKitmustbeusedwithmanufacturedhomeinstallations.
3. Residential: The3inch(76mm)verticalTopVentAdapterKitandthe3to6inch(76-152mm)TopVentOffsetAdapteraretestedtouse24gaugesinglewallflueconnectororListeddoublewallflueconnectortoClassAListedmetalchimneys, ormasonry chimneysmeeting InternationalConferenceofBuildingOfficials(ICBO)standardsforsolidfuelappliances.
4. INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
5. Secure exhaust venting system to the appliancewithat least3screwsor rivetsper thepipemanufacturer’sinstructions.Alsosecureallconnectorpipejointswithatleast3screwsthrougheachjoint.
6. DONOTINSTALLAFLUEDAMPERINTHEEXHAUSTVENTINGSYSTEMOFTHISUNIT.
7. DONOTCONNECTTHISUNITTOACHIMNEYFLUESERVINGANOTHERAPPLIANCE.
NOTE: All pipe must be welded seam pipe whenever pos-sible. Seal pipe joints with high temperature silicone (500°F [260°C] minimum rated only). Do not put silicone inside of pipe.
B. Venting Termination Requirements
1. Terminationmustexhaustaboveairinletelevation.It is strongly recommended that at least 60 inches (1.5m) of vertical pipe be installed when appliance is vented directly through a wall.Thiswillcreateanaturaldraft,whichwillhelppreventthepossibilityofsmokeorodorventing into thehomeduringapoweroutage. Itwillalsokeepexhaustfromcausinganuisanceorhazardbyexposingpeopleorshrubstohightemperatures.Thesafestandpreferredventingmethodistoextendtheventverticallythroughtheroof.
2. Distancefrom doorsandopeningwindows,orgravityorventilationairinletsintobuilding:a. Notlessthan48inches(1.2m)below;b. Notlessthan48inches(1.2m)horizontallyfrom;c. Notlessthan12inches(305mm)above.
3. Distancefrompermanentlyclosedwindows;a.Notlessthan12inches(305mm)below;horizontally
fromorabove.4. Distancebetween bottomofterminationandgradeshould
be12 inches (305mm)minimum. This is conditionaluponplants in thearea,andnatureofgradesurface.Thegradesurfacemustbeanon-combustiblematerial(i.e.,rock,dirt).Thegradesurfacemustnotbelawn.Distance between bottom of termination and publicwalkwayshouldbe7feet(2.13m)minimum.
5. Distance to combustible materialsmust be24 inches(610mm)minimum. This includesadjacentbuildings,fences,protrudingpartsofthestructure,roofoverhang,plantsandshrubs,etc.
6. TerminationCapLocation(HomeElectricalService)• Side-to-sideclearanceistobethesameasminimum
clearancetovinylinsidecorners.• Clearanceofaterminationcapbelowelectricalservice
shallbethesameasminimumclearancetovinylsoffits.• Clearanceofaterminationcapaboveelectricalservice
willbe12inches(305mm)minimum.• Locationoftheventterminationmustnotobstructor
interferewithaccesstotheelectricalservice.
VentsurfacesgetHOT,cancauseburnsiftouched.Non-combustibleshieldingorguardsmayberequired.
WARNING
WARNING
ONLYuseconnector:• Withintheroom,betweenapplianceandceilingorwall.ConnectorshallNOTpassthrough:• Atticorroofspace• Closetorsimilarconcealedspace• FloororceilingMaintainminimumclearancestocombustibles
Fire Risk.FollowChimneyConnectorManufacturer’sInstructionsforProperInstallation.
8 Vent Information
![Page 26: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/26.jpg)
7083-171B • July 23, 2013 (877) 427- 331626
C. Pellet Venting Charts
FireRisk.• Only LISTEDventing componentsmaybeused.
• NOOTHERventcomponentsmaybeused.Substituteordamagedventcomponentsmayimpairsafeoperation.
WARNINGThemaximumhorizontalventingallowedwithnoverticalvent-ingattached is48 inches (1219mm) includingone90°elbowortwo45°elbows.Thisisourrecommendedhorizontalvent-ing installation. Additionofanyhorizontalventingbeyond48inches(1219mm)requiresaminimum60inches(1524mm)ofadditionalverticalvent.Horizontalsectionsofventpipeshouldhavea1/4inch(6.35mm)riseperfoot.
Pelpro recommends any installation requiringmore than two90°elbows,ormorethan15feet(4.5m)ofventingtouse4inch(102mm)vent. NOTICE: Theseareguidelinesforsuccessfulventing
ofyourpelletappliance.Themoreverticalriseyoucanobtaininyoursystem,thebetteritwillperform.Horizontalventrunscanaccumulateashandwillneedtobecleanedmoreoften.Trytokeepthemasshortaspossible.
45° elbow is equivalent to 1 foot of straight pipe
90° elbow is equivalent to 3 feet of straight pipe
Minimum Vertical Vent for One Elbow
0
5
10
15
20
0 5 10 15 20
Horizontal Run, (ft)
Min
imum
Ver
tical
Ris
e (ft
)
Horizontal Run (FT)
Minimum Vertical Vent for One Elbow
Minimum Vertical Vent for Three Elbows
0
5
10
15
20
25
0 2 4 6 8 10 12
Length of Horizontal Sections (ft)
Min
imum
Ver
tical
Ris
e (ft
)
Minimum Vertical Vent for Three Elbows
Length of Horizontal Sections (FT)
Minimum Vertical Vent for Two Elbows
0
5
10
15
20
0 5 10 15
Length of Horizontal Sections, (ft)
Min
imum
Ver
tical
R
ise,
(ft)
Minimum Vertical Vent for Two Elbows
Length of Horizontal Sections (FT)
ONE 90° ELBOWTotal
HorizontalMinimumVertical
VentDiameter
4 0 35 5 36 6 37 7 38 8 49 9 4
10 10 411 11 412 12 413 13 414 14 415 15 416 16 417 17 418 18 419 19 4
TWO 90° ELBOWSTotal
HorizontalMinimumVertical
VentDiameter
2 5 33 6 34 7 35 8 36 9 37 10 48 11 49 12 4
10 13 411 14 412 15 413 16 414 17 415 18 4
THREE 90° ELBOWSTotal
HorizontalMinimumVertical
VentDiameter
2 11 43 12 44 13 45 14 46 15 47 16 48 17 49 18 4
10 19 411 20 4
![Page 27: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/27.jpg)
www.pelprostoves.com 7083-171B•July23,2013 27
We strongly recommend a minimum of 60 inches (1.5m) vertical, however above the eave is pre-ferred.
Both installationsare approved formobile home instal-lations.Mustuse3or4inch(76to102mm)“L”or“PL”ListedpelletventingorListeddoublewallpipeandautho-rizedOutsideAirKitinmobilehomes.Singlewallpipeisapprovedforresidentialinstallationsonly.
Air Clearance to Pipe:Thisappliancewastestedwithstandard3 inch(76mm)Listedpelletvent.PelletpipemanufacturersListedreducedclearancepipemaybeuseforreduceclearancefrom3inch(76mm)airclearancetonolessthan1inch(25mm)airclearancetocombustiblesforapprovedListedpelletpipe.Follow pipe manufactures listed air clearances to com-bustibles and installation instructions for all reduced air clearances installations.
C. Vertical into Existing Class A ChimneyA. Vertical - Interior - Typical Installation
PREFERRED METHOD #1
B. Through The Wall & Vertical - External - Horizontal
PREFERRED METHOD #2
Non-combustible Hearth Pad
Clean-out Cover
Tee
Wall Thimble
Support Bracket
Every 60 in. (1.5 m)
12 in. (305mm) Minimum
Rain Cap
Flashing
2 in. (50.8 mm) Minimum
6 in. (152 mm)Minimum
Firestop
Flashing
Rain Cap
Non-combustible Hearth Pad
Follow vent manufacturer’s clearances for reduced clearances
12 in. (305mm) Minimum
Ceiling Support
6 in. (152mm) Flue Connector
6 in. (152mm) Class A Chimney Connector Adapter
6 in. (152mm)
Min.10 in. (254mm) Min.
Clean-out T
6 in. (152mm)
Min.
10 in. (254mm) Min.
Clean-out T
Firestop
Flashing
Rain Cap
Non-combustible Hearth Pad
12 in. (305mm) Minimum
Ceiling Support
9 Venting Systems
![Page 28: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/28.jpg)
7083-171B • July 23, 2013 (877) 427- 331628
FireRiskInspectionofChimney:• Masonrychimneymustbeingoodcondition.• MeetsminimumstandardofNFPA211• Factory-builtchimneymustbeminimum6inch
(152mm)UL103HT.
WARNING
E. Alternate Masonry
D. Masonry
Improperinstallation,adjustment,alteration,serviceormaintenancecancauseinjuryorpropertydamage.Refertotheowner’sinformationmanualprovidedwiththisappli-ance.Forassistanceoradditionalinformationconsultaqualifiedinstaller,serviceagencyoryourdealer.
WARNING
Non-combustible Hearth Pad
Airtight Clean-out Door
Sheathing
2 in. (50.8mm) Minimum
Flashing
1 in. (25mm) Clearance1 in. (25mm) Clearance with Firestop
6 in. (152mm) Minimum
Fireclay Flue Linerwith AirspaceConcrete
Cap
AirtightClean-Out Door
Clean-Out
Sheathing
3 in. (76mm) Minimum
1 in. (25mm) Clearance
Flashing
Fireclay flueLiner with AirspaceConcrete Cap
1 in. (25mm) Clearancewith Firestop
6 in. (152mm) Minimum
Non-combustible Hearth Pad
![Page 29: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/29.jpg)
www.pelprostoves.com 7083-171B•July23,2013 29
F. Through The WallHorizontalterminationcapmustbeaminimumof6inches.(152mm)fromthewall. Approvedformobilehomeinstal-lations.Mustuse3or4inch(76-102mm)“L”or“PL”listedpelletventingorListeddoublewallpipeandanauthorizedOutsideAirKitinmobilehomes.
InCanada,wherepassagethroughawallorparti-tion of combustible construction is desired, theinstallationshallconformtoCAN/CSA-B365
NOTICE:
Pleasenote thatwhile theminimumclearance for theterminationcap is6 inches(152mm) there is thepos-siblyofsootbuild-uparoundtheterminationarea.Ifthisoccurswesuggesttomovetheterminationfurtherawayfromthehousetopreventit.Thesuggestedminimumis12inches.
Straight Out
45 Degree
DONOTDOWNWARDVENT. Thefollowingwilloccur: • Theappliancewillnotventproperly • Smokespillageinthehouse • Excessivesooting
CAUTION
WallThimble
Illustration shows venting going in both directions.Choose which one is best for your installation.
3 in. (76mm)Minimum
3 in.(76mm)
Minimum
6 in (152mm) Minimum
6 in (152mm) Minimum
6 in. (152mm) Minimum
Non-combustible Hearth Pad
Wall Thimble
Horizontal Termination Cap
10 in. (254mm) Minimum
6 in. (152mm) Minimum
From Glass
![Page 30: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/30.jpg)
7083-171B • July 23, 2013 (877) 427- 331630
1. Anoutsideairinletmustbeprovidedforthecombustionairandmustremainclearofleaves,debris,iceand/orsnow.Itmustbeunrestrictedwhiletheapplianceisinusetopreventroomairstarvationwhichcausessmokespillage.Smokespillagecanalsosetoffsmokealarms.
2. Thecombustionairductsystemmustbemadeofmetal.Itmustpermitzeroclearancetocombustibleconstruc-tionandpreventmaterialfromdroppingintotheinletorintotheareabeneaththedwellingandcontainarodentscreen.
3. Theappliancemust be secured to themobile homestructurebyboltingittothefloor(usinglagbolts)withtwoattachmentpoints.Usethesameholesthatsecuredtheappliancetotheshippingpallet.
4. Theappliancemustbegroundedwith#8solidcoppergroundingwireorequivalent,terminatedateachendwithanNECapprovedgroundingdevice.
5. Refer toClearances toCombustibles and floor pro-tection requirements for listings to combustiblesandappropriatechimneysystems.
6. Usesiliconetocreateaneffectivevaporbarrieratthelocationwherethechimneyorothercomponentpen-etratestotheexteriorofthestructure.
7. Followthechimneymanufacturer’sinstructionswheninstallingtheventsystemforuseinamobilehome.
8. InstallationshallbeinaccordancewiththeManufactur-ersHome&SafetyStandard(HUD)CFR3280,Part24.
InstallationmustcomplywithManufacturedHomeandSafetyStandard(HUD),CFR3280,Part24.
WARNING
You must use an authorized Outside Air Kit for installation in a mobile home.
A. Mobile Home Installation
Spark Arrestor Cap
Roof Flashing
Storm Collar
Joist Shield/Firestop Approved Class “L” or “PL” Pellet Vent
CAUTIONNeverdrawoutsidecombustionairfrom:• Wall,floororceilingcavity• Enclosedspacesuchasanattic,garageor
crawlspace.
CAUTIONTHESTRUCTURALINTEGRITYOFTHEMOBILEHOMEFLOOR,WALLANDCEILING/ROOFMUSTBEMAIN-TAINEDDoNOTcutthrough:• Floorjoist,wall,studsorceilingtrusses.• Anysupportingmaterialthatwouldaffectthestructural
integrity.
NEVERINSTALLINASLEEPINGROOM.Consumesoxygenintheroom.
WARNINGAsphyxiation Risk.
10 Mobile Home
![Page 31: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/31.jpg)
www.pelprostoves.com 7083-171B•July23,2013 31
CAUTIONNeverdrawoutsidecombustionairfrom:• Wall,floororceilingcavity• “Enclosedspacesuchasanattic,garageor
crawlspace.
A. Outside Air Kit Instructions
Anoutsideairkithasbeenprovidestandardwiththeappli-ance.Itishighlyrecommendedtousetheoutsideairkitformaximumperformanceandtoreduceeffectsfromnegativepressureinthehome.
Forattachment to thisplatform,knockout the rectangularplateintherearoftheunitandslidethetubeintherearoftheunit.Usingthehoseclamp,attachtheflexpipetothe2”tubeweldedtotherearofthefireboxasshowninthephoto.
Shockhazard.• DoNOTremovegroundingprongfromplug.• Plugdirectlyintoproperlygrounded3prong
receptacle.• Routecordawayfromappliance.• DoNOTroutecordunderorinfrontofappli-
ance.
CAUTION
B. Power up the Unit
Plugtheunitinto120VACpower.
WARNING
DISCONNECTSUPPLYBEFORESERVICING.
11 Appliance Set-Up
![Page 32: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/32.jpg)
7083-171B • July 23, 2013 (877) 427- 331632
Symptom Possible Cause Corrective ActionPluginappliance-Noresponse.
NoPowertooutlet.5ampfusedefectiveorblownSnapdisctrippedordefective.
Checkcircuitbreakeratservicepanel.Replacefuse.Resetorreplacesnapdisc.
UnitWillNotLight NoFuelOutoffuel.Vacuumswitchnotclosing,novacuum.
Hopperlidopen.Defectivehopperswitch.FeedSystemisJammedFeedmotornotpluggedin
NoIgniterIgniternotpluggedinIgniternotcentered
Igniterdefective
FirepotPluggedFirepotdirty
FirepotinbackwardsToomuchdebrisinthebottomofthefirepot
Checkhopper.Fillwithfuel.Checkexhaustblowerispluggedinandoperating.CheckvacuumswitchispluggedinCheckvacuumhoseisingoodconditionclearandconnectedatbothendsMakesureventingsystemiscleanMakesurefrontdoorisclosedCheckvacuumswitchfittingonsideoffeedtubeforblockageCloseHopperLidCheckhopperswitchoperationInspectandunjamthefeedassemblyReconnectfeedmotor
PlugtheigniterinCentertheigniterIgniterseatedinchambercompletelyReplaceigniter
CleanfirepotCleanbelowthefirepotPutthefirepotinthecorrectdirectionCleanfirepot
Firestartsbutgoesout Firepotisdirty
Exhaustpathand/orventingisplugged
ExhaustsensorcannotreadcorrecttemperatureExhaustpathisdirty
Exhaustprobeisnotattachedtooutlet
ExhaustprobeisnotpluggedintotheboardExhaustprobeisdefective(errorcodemayresult)
Cleanfirepot.Checkflueventforobstruction
Inspectandcleanexhaustpathandventingcleanfireboxincludingbehindthebaffles
Inspectandcleantheexhaustoutletespeciallytherightsidewall.RemovetherightsidepanelandinspecttoseeiftheexhaustprobeisattachedandtightagainsttheexhaustoutletPlugtheprobeintotheboardReplacetheexhaustprobe
Unitstartandstopsfrequentlywhenoperatingintheautomaticmode
Areaweretheunitisinstalledheatsandcoolsquicklydependingoninstallationconfiguation.Tightspacesalsomayhaveaneffectontheon/offcyclingoftheunit.
AmbientprobeProbetouchingheatedsurface
Checktheproximitytodoorsandwindowsand/orinsulationfactorofthestructure.IfheatlossisquicktheunitmayneedtorunonHIorLO.
Inspecttheprobeandmakesureitisnottouchingasurfacethatheatsandcoolsquickly.Theambientprobehasadditionalwireinsiderearcavitywhichcanbeusedtoincreasethedistancefromtheunit.
12 Troubleshooting
![Page 33: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/33.jpg)
www.pelprostoves.com 7083-171B•July23,2013 33
Symptom Possible Cause Corrective ActionSloworsmokystart-upand/orlazyflame
Dirtyexhaustand/orventingsystem.
Notenoughcombustionair
MisalignedigniterWetfuel/poorqualityfuel
Checkforashbuildupinunit,includingbehindrearpanels,firebox,exhaustblowerandventing.Adjustthetrim
CentertheigniterinthechamberReplacefuel
Convectionblowerfailstostart.
ConvectionBlowerJammedNotpluggedin
ExhaustprobeNotsensingcorrecttemperature
Controlboxisdefective.
Inspect,clean,andun-jamtheblower.PlugtheblowerinReplaceblower
Cleantheexhaustoutletespeciallytherightside.
Replacecontrolbox.Exhaustblowerfailstostart
ExhaustBlowerJammedNotpluggedin
Controlboardisdefective.
Inspect,clean,andun-jamtheblower.PlugtheblowerinReplaceblower
Replacecontrolboard.ConvectionBlowerDoesNotTurnOff
Convectionblowershortcircuit.Thefusewillbeblownanduponreplacementofthefuse,theblowerwillruncontinuously.
Inspectwires,blowers,andpowercordtofindcauseofshortcircuit.Replaceboardandfailedcomponent.
ConvectionBlowermakesnoise
Screwsattachingconvectionblowertoappliancehavebecomeloose.
Convectionblowerisdirty
Tightenscrews
CleanblowerimpellersExhaustBlowerDoesNotTurnOff
Exhaustblowershortcircuit.Thefusewillbeblownanduponreplacementofthefuse,theblowerwillruncontinuously.
Inspectwires,blowers,andpowercordtofindcauseofshortcircuit.Replaceboardandfailedcomponent.
Igniterdoesnotturnoff Ignitershortcircuit.Thefusewillbeblownanduponreplacementofthefuse,theigniterwillremainonwhenunithaspower.
Inspectwires,blowers,andpowercordtofindcauseofshortcircuit.Replaceboardandfailedcomponent.
Feedmotordoesnotshutoff
Feedmotorshortcircuit.Thefusewillbeblownanduponreplacementofthefuse,thefeedmotorwillremainonwhenunithaspower.
Openhoppertostopthefeedmotor.Inspectwiresfeedmotor,controlboard,andpowercordtofindsourceofshortcircuit.Replacecontrolboardandfailedcomponent.
Unitfailstoshutoff. Unitrunninginmaximumorminimum TurndialcontroltoAutomaticorOffposition.SeeAlso,“FeedMotorDoesNotShutOff”.Theunitshouldgointoashutdown.
Large,lazyflame,orangecolor.Blackashonglass.
Dirtyappliance.Poorfuelquality,highashcontent.
Incorrectair-fueladjustment
Excessivefeeding/FeedMotorlockedon
Cleanunit,includingfirepotandventingsystem.Cleanexhaustpath.Tryadifferentbrandofpellets.
TurnfueladjustmenttrimdialtoLEFTtoincreasecombustionairspeed.Followcorrectiveactionforfeedmotordoesnotturnoffsymptom.
Excessivefuelspillingoverthefirepotintotheashwellsand/orexces-siveflame
Excessivefeeding/FeedMotorlockedon Followcorrectiveactionforfeedmotordoesnotturnoff.
Blacksootonthesideofthehouse
Exhaustpathisdirty.Excessivefeeding/FeedMotorlockedon
Incorrectair-fuelratio
CleanExhaustpathFollowcorrectiveactionforfeedmotordoesnotturnoffsymptom.TurnfueladjustmenttrimdialtotheLEFTtoincreasecombustionairspeedSee“TrimAdjustment”sectiononPage9.
![Page 34: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/34.jpg)
7083-171B • July 23, 2013 (877) 427- 331634
Alarm (LED Flashing RED)
Possible Cause Corrective Action
1 Flash: Empty Hopper NofuelisdeliveredtothefirepottosustainflameHopperempty(mostlikely)AugerJam(nextlikely)NovacuumHopperlidopen
FlameisevidentbuttheexhaustprobeisnotabletorecognizethehotexhausttemperatureExhaustprobenotattachedtooutletExhaustpathisdirty
Fillthehopper,inspectthefeedtubeforjams,inspecttheventingandfireboxforobstructionsandcleanifnecessary,inspecttheexhaustblowertomakesureitruns,orclosethehopperlid.
Inspectandcleantheexhaustoutlet,firebox,firepot,andbehindthebaffles.Inspecttheexhaustprobetoseeifitissecurelyattachedtothesideoftheexhaustoutlet.
2 Flashes: Exhaust Probe Fail
Theexhaustprobesensesatemperatureoflessthannegative20degreesCelsiusorabove300degreesCelsius.
Theexhausttemperatureisaboveorbelowtheacceptablerange.
ExhaustProbeFailureNotpluggedinFailedcomponent
PlugtheprobeintotheboardReplacethecomponent
3 Flashes: Ambient Probe Alarm
Theambientprobesensesatemperatureoflessthannegative20degreesCelsiusorabove70degreesCelsius.
Theambienttemperatureisaboveorbelowtheacceptablerange.
AmbientProbeFailureNotpluggedinFailedcomponent
PlugtheprobeintotheboardReplacethecomponent
4 Flashes: Missed Igni-tion
Duringtheignitionsequencetheloaddoesnotignite.Theunitwillautomaticallyretryoncefromthefirstfailedattempt.
FuelNofuelHopperEmptyFeedJamFeeddoesn’tturnFeedmotordisconnectedorfailed
FirepotFirepotDirtysofuelisnotnearignitionholeinthefirepot
IgniterNopowerDebrisintheendoftheigniterchamber
FillthehopperInspectandclearjaminthefeedtubeInspectthefeedmotorcircuit(hopperlidmustbeclosed,vacuumswitchmustbeclosed(ieexhaustbloweron),andfeedmotormustbepluggedin.
Cleanthefirepot
Checkleadsandiftheigniterworks.Cleantheendoftheigniterchamberfrominsidethefirebox(removalofthefirepotrequiredforthisstep).
8 Flashes: Exhaust Over Temperature
Theexhausttemperaturehasexceededtheallow-abletemperature.
FuelFeedMotorLockedOn
Non-approvedfuelused
ConvectionblowerDirtyFailed
InstallationInstallationconfigurationistightallowingforlimitedaircirculationaroundtheunit.
Reviewthefeedmotorandfeedrates.Normalfeedmotoroperationisonbetween1*and4*secondsoutofevery7seconds.(*dependingonmodelandburnratesetting)Ifthefeedmotordoesnotturnoff,replacethecontrolboard.Reviewthefuelbeingused.
CleanReplace
Reviewtheinstallationandmoveifnecessary.
Following correction of any Alarm, turn the dial control to the OFF position, wait 10 seconds andturn back to desired setting OR unplug the unit, wait 10 seconds then restore power.
![Page 35: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/35.jpg)
www.pelprostoves.com 7083-171B•July23,2013 35
13. Snap Disc (Back Burn Protector) 200°FSnapdiscismountedonthebackoftheaugertubeinthecenteroftheapplianceandhasaresetbutton.Therearetwogreywiresconnectedtoit.Toaccessitremovetherightsidepanel.Ifthefiretriestoburnbackintothefeedsystemorpushexhaustupthefeedtube,thissnapdiscwillshuttheentiresystemoff.Unplugthestovepriortoresetting.14. Vacuum SwitchThevacuumswitchislocatedonthelowerrightsideoftheappliancebehindrightsidepanel.Therearetworedwiresattached to it.This switch turns the feed systemonwhenvacuumispresentinthefirebox.Thevacuumswitchisasafetydevicetoshutoff thefeedmotor if theexhaustortheheatexchangersystemisdirtyorpluggedorifthefireboxdoorisopenorexhaustblowerfailure.15. Outside air inletTheoutsideairtubecanbeattachedtothe2”ODinlettubemountedtotherearofthefirebox.Toextendthehoseoutsidetheunitthereisaknockoutplatethatmustberemoved.
When describing the location of a component, it is always AS YOU FACE THE FRONT OF THE APPLIANCE.
1. Control BoardThecontrolboardislocatedontherightsideoftheappliancebehindthelowerrightsidepanel.2. Convection BlowerTheconvectionblowerismountedintherearoftheunit.Itpushesairuptherearofthefirebox,acrossthetopandoutthefront.Astheairmovespastthefireboxitisheated.3. Exhaust BlowerThe exhaust blower ismounted on the left side of theappliance.Theexhaustblowerisdesignedtopulltheexhaustfromtheapplianceandpushitoutthroughtheventingsystem.4. Feed SystemThefeedsystemcanbeaccessedintwoareas.Toaccesstheaugerspring,removethecoverinthehopper.Toremovethefeedmotor,removethesidepanelandmotorcoverplateintherearoftheunit.5. FirepotThefirepotismadeofacombinationofstainlesssteelandheavydutycoldrolledsteel.Itisremovabletoaidincleaning.6. FuseThefuseislocatedonthecontrolboard.Thefusewillblowshouldashortoccurandshutoffpowertotheappliance.7. Dial ControlThedialcontrolisattachedtotherightsideoftheappliance.The largedialcontrols theheatoutputwhereasthesmalldialbelowthelargedialisthetrimfeature.TheLEDblinksaccordingtothestateoftheappliance.8. Hopper SwitchThehopperswitchislocatedintheupperrighthandcornerofthehopper.Thisswitchisdesignedtoshutdownthefeedmotorwheneverthehopperlidisopened.9. IgniterTheigniterismountedinthechamberintherearofthefireboxbelowtheconvectionblower.Combustionairtravelsovertheredhotignitercreatingsuperheatedairthatignitesthepellets.10. Power SupplyThepowercordconnectorintherearoftheunit.Checkthewallreceptaclefor120volt,60Hz(standardcurrent).Makesuretheoutletisgroundedandhasthecorrectpolarity.Agoodsurgeprotectorisrecommended.11. Exhaust ProbeTheexhaust probe ismounted to the sideof theexhaustoutletintherearoftheunit.Itsensesthetemperatureoftheexhaustandallowsthecontrolsystemtomakedecisions.12. Ambient ProbeTheambientprobeislocatedinthebackpanel.Ithasextrawiretoincreasedistancefromapplianceifneeded.
A. Component Function E13 Reference Materials
![Page 36: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/36.jpg)
7083-171B • July 23, 2013 (877) 427- 331636
M
M
M
110 VLINE
NEUTRAL
IGNITER
FEED MOTOR
EXHAUST BLOWER
CONVECTION BLOWER
VACUUMSWITCH
HOPPERSWITCH
AMBIENTTEMPERATURE
EXHAUSTTEMPERATURE
SERIAL PORT(SERVICE ONLY)
BLAC
KW
HITE
PURP
LEPU
RPLE
BLUE
BLUE
RED
RED
BLAC
KBL
ACK
POT SET TEMP VCCPOT SET TEMP GNDPOT SET TEMP SIG
POT FEED ADJUST VCCPOT FEED ADJUST GNDPOT FEED ADJUTS SIG
LED REDLED AMBERLED GREEN
FUSE
SNAPDISC
B. Wiring Diagram
![Page 37: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/37.jpg)
www.pelprostoves.com 7083-171B•July23,2013 37
C. Replacement Parts 1
2
5
49 78
1110
3
14
1213
1516
15.1
15.2
3.4
3.2 3.1
3.3
6
3.5
ITEM DESCRIPTION COMMENTS PARTNUMBER STOCKEDatDEPOT
1 HOPPERLIDASSEMBLY SRV7083-019
2 SIDECURTAINLEFTHAND SRV7083-154
3 DOORASSEMBLY SRV7083-021
3.1 GLASSASSEMBLY SRV7081-173
3.2 ROPE,DOOR,3/4”X84” 832-1680 Y
3.3 HINGE PIN QTY: 2 433-1590/2
3.4 THREADEDHINDLEASSEMBLYKIT KS-5140-1448
3.5 HANDLEBLACKPHENOLICKIT KS-5140-1442
4 BAFFLEKIT SRV7079-006
5 FIREPOT SRV7077-003
6 CONTROLBOARD SRV7079-050
7 CONVECTIONBLOWER SRV7000-659
8 IGNITERKIT SRV7000-660
9 IGNITERCHAMBERKIT SRV7077-110
10 EXHAUSTCOMBUSTIONBLOWER 812-4400 Y
11 SNAPDISCMANUALRESET SRV230-0080 Y
12 VACUUMSWITCH SRV7000-531 Y
VACUUMHOSE,5/32ID QTY:3FEET SRV240-0450 Y
13 SIDECURTAINRIGHTHAND SRV7083-153
14 DIALCONTROLKIT INCLUDESWIREHARNESS SRV7038-036
15 HOPPERSIWTCH SRV7000-612 Y
16 FEEDASSEMBLYKIT SRV7077-014
16.1 FEEDSHAFTBUSHING QTY: 2 7000-600/2
16.2 FEEDMOTOR SRV7000-670
AMBIENTPROBE SRV7000-668
EXHAUSTPROBE SRV7000-669
WIREHARNESS SRV7077-184
WIRECLIP QTY: 10 7000-400/10 Y
*WHEN ORDERING REPLACEMENT PARTS, SPECIFY MODEL TO GET THE CORRECT PARTS.
![Page 38: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/38.jpg)
7083-171B • July 23, 2013 (877) 427- 331638
Date of Service Performed By Description of Service
D. Service & Maintenance Log
![Page 39: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/39.jpg)
www.pelprostoves.com 7083-171B•July23,2013 39
PelPro Appliances ComponentsCovered
Warranty Period
Parts Labor Pellet
1 Year No Coverage
X Electrical
5 Years No Coverage
X Steel Parts (excluding burn grate)
90 Days No Coverage
X All replacement parts beyond warranty period
WARRANTY EXCLUSIONS:The warranty does not cover damage or breakage due to misuse, improper handling or modifications. There specifically is no warranty on the paint, glass, burn grate, fire brick and all gaskets or against damage caused from corrosion. There is no written or implied performance warranty on PelPro SERIES stoves as the manufacturer has no control over the installation, operations, cleaning, maintenance or the type of fuel burned.
This Warranty is Void If:-Stove has not been installed, operated, cleaned and maintained in strict accordance with the manufacturer's instructions.-Burning other than quality wood pellets may void the warranty.
WARRANTY EXCLUSIONS:Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitations of implied warran-ties, so the limitations or exclusions set forth in this limited warranty may not apply to you. This limited warranty gives you specific legal rights and you may have other rights, which vary from state to state.
NEITHER THE MANUFACTURER, NOR THE SUPPLIERS TO THE PURCHASER, ACCEPTS RESPONSIBILITY, LEGAL OR OTHERWISE, FOR THE INCIDENTAL OR CONSEQUENTIAL DAMAGE TO THE PROPERTY OR PERSONS RESULTING FROM THE USE OF THIS PRODUCT. ANY WARRAN-TY IMPLIED BY LAW, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS, SHALL BE LIMITED TO ONE (1) YEAR FROM THE DATE OF ORIGI-NAL PURCHASE. WHETHER A CLAIM IS MADE AGAINST THE MANUFACTURER BASED ON THE BREACH OF THIS WARRANTY OR ANY OTHER TYPE OF WARRANTY EXPRESSED OR IMPLIED BY LAW, MANUFACTURER SHALL IN NO EVENT BE LIABLE FOR ANY SPECIAL, INDIRECT, CONSEQUENTIAL OR OTHER DAMAGES OF ANY NATURE WHAT-SOEVER IN EXCESS OF THE ORIGINAL PURCHASE PRICE OF THIS PRODUCT. ALL WARRANTIES BY MANUFAC-TURER ARE SET FORTH HEREIN AND NO CLAIM SHALL BE MADE AGAINST MANUFACTURER ON ANY ORAL WAR-RANTY OR REPRESENTATION.
Your purchase must be registered with HEARTH & HOME TECHNOLOGIES. This can be done online at www.pelprostoves.com.
PARTS, SERVICE, AND RETURNS:It is Hearth & Home Technologies policy, that NO pellet appliance be returned to any dealer without prior authorization from Hearth & Home Technologies Consumer Care Department. We strongly suggest that if you do need to order any parts or options or require service, that you first deal with your local dealer. Many dealers do stock parts and options. The majority of the parts names can be found within this manual.
If for any reason you do not have a local dealer, Hearth & Home Technologies is proud to offer the best technical and sales support in the industry. Call TOLL FREE 1-877-427-3316.
Hearth & Home Technologies, Inc.PELPRO LIMITED WARRANTY
Hearth & Home Technologies Inc., on behalf of its hearth brands (“HHT”), extends the following warranty for PELPRO wood and pellet hearth appliances that are purchased from an HHT authorized dealer.
WARRANTY COVERAGE:If an inspection by the dealer indicates that a limited warranty claim is justified, and all conditions of this limited warranty have been met, the manufacturer's total responsibilities and liabilities shall be to repair or replace, at the manufacturer's option, the defective part(s).
WARRANTY PERIOD:All claims under this limited warranty must be made through the dealer where your stove was purchased. All costs of removal, shipment to and from the dealer or manufacturer, any losses during shipment and reinstallation, and any other losses due to your stove being removed, shall be covered by the owner of the stove. The warranty period for parts and labor for cov-ered components is produced in the following table.
E. Warranty
![Page 40: Owner s Manual - Northern Toola released 72906 06/20/13 mcw label operation and maintenance mcw nts see note 1 of 1 7083-168 a note: 1. material: non-anodized aluminum 0.020 thick](https://reader034.fdocuments.in/reader034/viewer/2022042309/5ed6716a6ff22a66535f4e84/html5/thumbnails/40.jpg)
7083-171B • July 23, 2013 (877) 427- 331640
We recommend that you record the following pertinent information for your heating appliance.
Date purchased/installed:
Serial Number: Location on appliance:
Store purchased from: Store Location:
Notes:
Please contact the Hearth & Home Technical Group withany questions or concerns.
www.pelprostoves.comFor Customer Service 1-877-447-3316
Prior to calling, please have the model, serial number, and sales receipt of the unit you are calling about. This information can be found at the rear of the unit.
CONTACT INFORMATION:1445 North HighwayColville, WA 99114
Hearth & Home Technologies1445 North Highway
Colville, WA 99114Division of HNI INDUSTRIES