Access Control | Readykey™ Controller Retrofit Kits
retrofitkit
READYKEY™
Simplifies a hardware upgrade from
Readykey K2100 and K2200 door controllers
to the current generation PAC 512-series
Ideal for maintenance replacement and out
of warranty panels
Offers a cost effective, direct swap out for
K2000-series (K1100, K1200, K2100 and
K2200) to PAC 500-series controllers.
Upgrade and extend the life of a Readykey™
system without the disruption of physically
removing and replacing the entire
installation, using the existing cabling,
readers and without the need to re-enroll
cards or key fobs
Overview
Like any capital equipment evaluation, security managers face tough choices in retaining andmaintaining their Access Control system, compared with a full overhaul and transition to newequipment. If the system is still performing, meeting the business requirements, a full replacement islow on the capital planning schedule.
Beyond upgrading or replacing the system, there are certainly additional capital and transition costsinvolved in a system overhaul. A full replacement requires the replacement of existing controllers,proximity readers, credentials, power supplies, enclosures, most of the cabling and connections. Further,a full replacement may draw vital capital resources away from other and perhaps more criticalupgrades to Burg, Fire or CCTV systems.
Path to Retrofit
The alternative to a full system replacement is a phased-in, upgrade strategy and deployment of next-generation of door controllers, with a specially engineered Retrofit Kit. This one-of-a-kind accesscontrol solution provides an easy way to migrate existing Readykey K2000-series door controllers,extending functionality without having to rewire or reprogram cardholders. The existing door controllerchassis is simply removed from the enclosure and the new Retrofit Chassis put in its place. For anexperienced technician, most installations can be completed in 30 minutes or less with a minimumnumber of steps.
Making the most of your assets makes perfect sense. It is also good for the environment to continue tore-use serviceable elements of your installation. These cost-effective upgrades to the key component ofyour system can reveal hidden potential, giving you state-of-the-art performance as well as a future-proof system.
Whether you are replacing a defective K2000-Series Controller or installing a complete system-wideRetrofit, these Kits are a fast and easy way to upgrade your access control system with zero impact toproductivity, delivering modern controller technology and preserving existing investments in cabling,reader and lock wiring, enclosures and readers.
Features
Remove power and disconnectall terminal blocks from theK2000 Series Controller
Remove the existing Chassis Plate (with power supply and controller)
Transfer the existing powersupply to the new Retrofit Chassis and place
back into the enclosure
Connect the power adaptor and reconnectthe readers, locks and controllers
© Copyright 2015, Stanley Security Solutions, Inc. All Rights Reserved. The information contained herein is subject to change without notice. Stanley shall not be liable for technical or editorial errors or omissions contained herein.Stanley, PAC, Stanley PAC, One-Touch are registered trademarks of Stanley Security Solutions, Inc. Readykey is a registered trademark of Stanley Security Solutions, Inc in the European Union, UK and Australia and of Bosch Security Inc. in the USA. All other trademarks are the property of their owners. Rev. AJM6/15
Visit us at...
RETROFIT KIT CHASSIS
7S-K2RETRO Readykey Retrofit Kit- Steel Chassis Plate with mounting studs and screws for 2x PAC 512 controllers- 10A inline fuse for use with the battery- Power adaptor to connect the existing power supply. Screw terminals power the new controllers and battery backup(Controllers must be ordered seperately)
RETROFIT KIT CHASSIS WITH PREMOUNTED CONTROLLERS
7S-RK512IP Readykey IP Retrofit Kit with Premounted Controllers- Chassis Plate with Adapters and premounted with 1x 7S-512IP and 1x PAC 512-Series Controllers for four doors
7S-RK512 Readykey Retrofit Kit with Premounted Controllers- Chassis Plate with Adapters and premounted with 2x PAC 512-Series Controllers for four doors
ACCESSORIES
7S-512 Stanley PAC 512 - Two Door Access Controller (DIN-Rail Mount)
7S-512IP Stanley PAC 512IP - Two Door Access Controller (DIN-Rail Mount)
7S-K2207 Readykey™ K2100/K2200 8-Amp Power Supply UNIT
7S-20886 Line Driver for PAC 512 Controllers
-+ -+ -+ -+
4-DOOR CONTROLLER
kitfitoretr
rK2000Series C rontrolle rK2000Series C rontrolle
K2200 MASTER4-DOOR CONTROLLER
VEAAVK2100 SL
}erobef{:
-+ -+ -+ -+
RETROFIT KIT
Y)
OL
NERR
OL
OLL
TRR(C
ON
OC;
0.1
8A28
.0VD
- 1
0.5
:TU
INP
-2332RRS-23
V0
RD
T XT
SCT
XR
LY)
ON
ERRLEOO
LN
TRR(C
OOC;
0.1
8A28
.0VD
-2 1
0.5
T:U
INP
32RRS-2
V0
RD
T XT
SCT
XR
Y)
OL
NEER
LO
LLLTTR
(CN
(CO
NC;
0.1
8A28
.0VD
- 1
0.5
:TU
INP
32RS-2
V0
RD
T XT
SCT
XR
LY)
ON
EERER O
LO
LLN
TN
TR(C(C
OC;
0.1
8A28
.0VD
-28
10.
5:
1T
UIN
P
32RS-2
V0
RD
T XT
SCT
XR
RK5121 X RETROFIT KIT
7S-RK5121 X
}reaft{:
DMIN KITOFFICE
TTERYBA TTERYBA
TTERYBA TTERYBA
ADMIN KITOFFICE
TTERYBA
TTERYBA TTERYBA TTERYBA
ADMIN KIT
C SOFTWARAPANLEY T(SHOST PC
RE)
ENROLLMENT READER
R E
C SOFTWARE)APANLEY T(SHOST PC
ENROLLMENT READER