Overview of the Unique Requirements and Challenges for ...
Transcript of Overview of the Unique Requirements and Challenges for ...
![Page 1: Overview of the Unique Requirements and Challenges for ...](https://reader034.fdocuments.in/reader034/viewer/2022052017/6286697f8d69b56d130e1a43/html5/thumbnails/1.jpg)
Advanced Components & Systems Division
Medium Voltage Power Electronic Components
Overview of the Unique Requirements and Challengesfor Power Electronics in Mining Equipment
Presented by: Dustin SelveyCaterpillar, Inc.
March 23rd, 2016
![Page 2: Overview of the Unique Requirements and Challenges for ...](https://reader034.fdocuments.in/reader034/viewer/2022052017/6286697f8d69b56d130e1a43/html5/thumbnails/2.jpg)
Advanced Components & Systems Division
Medium Voltage Power Electronic Components
Summary1. Environmental Requirements
a) Protection against extreme temperaturesb) Dirt, debris and falling rocksc) Sealing against moistured) Chemical resistancee) Explosive environmentsf) Vibration and shock
2. Voltage and Power Scalability3. Serviceability Expectations
a) Ease of serviceabilityb) Component level access
4. Modular Designsa) Caterpillar product lineb) Power electronic building blocks
2
![Page 3: Overview of the Unique Requirements and Challenges for ...](https://reader034.fdocuments.in/reader034/viewer/2022052017/6286697f8d69b56d130e1a43/html5/thumbnails/3.jpg)
Advanced Components & Systems Division
Medium Voltage Power Electronic Components
Protection Against Extreme Temperatures
• Extreme cold– -50C Ambient
– Engine must be pre-heated to start
– Equipment is left running between shifts to avoid this
• Extreme heat– Maximum Ambient: +65C
– Coolant (water): +75C
– Coolant (oil): +85C
– Locomotive in a tunnel: • +85C for 10 minutes
• +110C for 1 minute
• Maximum delta: 15C/second3
![Page 4: Overview of the Unique Requirements and Challenges for ...](https://reader034.fdocuments.in/reader034/viewer/2022052017/6286697f8d69b56d130e1a43/html5/thumbnails/4.jpg)
Advanced Components & Systems Division
Medium Voltage Power Electronic Components
Dirt, Debris, and Falling Rocks• Structural shielding
required for protection against falling debris and collisions
• Excessive dust and rock material can be ingested by an inverter cooling system
• Conductive dust (surface mines)
• Explosive dust (coal mines)4
![Page 5: Overview of the Unique Requirements and Challenges for ...](https://reader034.fdocuments.in/reader034/viewer/2022052017/6286697f8d69b56d130e1a43/html5/thumbnails/5.jpg)
Advanced Components & Systems Division
Medium Voltage Power Electronic Components
Chemical and Weathering Resistance• Power electronics enclosures must be resistant to many
common mine chemicals including but not limited to:– Engine and transmission oils and additives
– Gasoline, kerosene, diesel fuel, and Urea
– Degreasers, soaps, and detergents
– Battery acid, muriatic acid, paint strippers, and alkaline cleaner
– Magnesium chloride and calcium chloride
• Enclosures must also be resistant to ambient conditions including:– Salt water splash and salt fog
– Ozone
– UV radiation
5
![Page 6: Overview of the Unique Requirements and Challenges for ...](https://reader034.fdocuments.in/reader034/viewer/2022052017/6286697f8d69b56d130e1a43/html5/thumbnails/6.jpg)
Advanced Components & Systems Division
Medium Voltage Power Electronic Components
Sealing Against Moisture
Submersion requirements– Submersion up to 1 meter
(including in salt water)
High pressure wash requirements– High pressure wash in all
directions (sometimes continuously during operation)
Moisture/humidity– In underground mining applications
the humidity is almost always 100% with condensation, drip, and high pressure water spray (for dust control)
6
![Page 7: Overview of the Unique Requirements and Challenges for ...](https://reader034.fdocuments.in/reader034/viewer/2022052017/6286697f8d69b56d130e1a43/html5/thumbnails/7.jpg)
Advanced Components & Systems Division
Medium Voltage Power Electronic Components
Explosive EnvironmentsUnderground soft rock mining (typically for coal) presents the added challenge of introducing an explosive atmosphere• Enclosure must contain an explosion within and not allow ignition of the surrounding
external gasses• Explosion tests are performed with varying amounts of methane gas and ignition
points• Static pressure tests are performed at 150 psi or 1.5 times the maximum recorded
pressure during the explosion testing
7
![Page 8: Overview of the Unique Requirements and Challenges for ...](https://reader034.fdocuments.in/reader034/viewer/2022052017/6286697f8d69b56d130e1a43/html5/thumbnails/8.jpg)
Advanced Components & Systems Division
Medium Voltage Power Electronic Components
Vibration and Shock
Examples of applications with vibration up to 10Grms:• Tracked equipment moving on hard rock or
cement• Driving on rough roads• Chain conveyors• Hard rock drills and cutting blades
Examples of applications with shock up to 100Grms”• Material loading and handling• Rail car coupling• Frequent collisions with the tunnel
wall
Typical verification testing includes:• Capability testing (to failure)• Response characterization• Combined Environmental Testing
8
![Page 9: Overview of the Unique Requirements and Challenges for ...](https://reader034.fdocuments.in/reader034/viewer/2022052017/6286697f8d69b56d130e1a43/html5/thumbnails/9.jpg)
Advanced Components & Systems Division
Medium Voltage Power Electronic Components
Voltage and Power Scalability
9
AP1055E Track Asphalt Paver70kW, 440Vac
8750 Dragline~33MW, up to 32kVac
Inverter component
794F AC Large Mining Truck2.5MW, 2200Vac
Motor control centerInverter cabinet
Voltage and power requirements vary greatly across the product line• There is a need for products that can be easily scaled
![Page 10: Overview of the Unique Requirements and Challenges for ...](https://reader034.fdocuments.in/reader034/viewer/2022052017/6286697f8d69b56d130e1a43/html5/thumbnails/10.jpg)
Advanced Components & Systems Division
Medium Voltage Power Electronic Components
Serviceability Expectations• To avoid significant downtime, the electronics must be serviceable in the
event of failure• Each service component must be available to ship to anywhere in the
world in less than 48 hours• Each component must be able to be removed, re-installed, and checked-
out in the field (often times in dark, damp, and dirty environments)
• Example: 795F AC Large Mining Truck inverter
• 220+ serviceable parts
• IGBTs, gate driver boards, capacitor, and heatsink are combined into one easily serviceable component (phase module)
10
![Page 11: Overview of the Unique Requirements and Challenges for ...](https://reader034.fdocuments.in/reader034/viewer/2022052017/6286697f8d69b56d130e1a43/html5/thumbnails/11.jpg)
Advanced Components & Systems Division
Medium Voltage Power Electronic Components
Modular Designs• The Caterpillar equipment product line consists of more than
300 different machines– Many include several different models and options
– Volume ranges from several thousand to less than one per year
11
![Page 12: Overview of the Unique Requirements and Challenges for ...](https://reader034.fdocuments.in/reader034/viewer/2022052017/6286697f8d69b56d130e1a43/html5/thumbnails/12.jpg)
Advanced Components & Systems Division
Medium Voltage Power Electronic Components
Modular Designs
• In order to reduce development costs, the power electronics must leverage multiple machines and be modular to fit new applications
• The component requirements end up taking on the worst-case from each targeted application
Phase Module• Modular building block
Highvibration
Highpower
Electric Rope Shovel
Hydraulic Mine ShovelLocomotive
Large Mining Truck
12
![Page 13: Overview of the Unique Requirements and Challenges for ...](https://reader034.fdocuments.in/reader034/viewer/2022052017/6286697f8d69b56d130e1a43/html5/thumbnails/13.jpg)
Advanced Components & Systems Division
Medium Voltage Power Electronic Components
Summary• Mining applications have unique and challenging requirements for power
electronics components
• Easy scalability for power and voltage is needed
• Quick and efficient field serviceability at a component level is expected
• Modular designs are highly desirable
13
![Page 14: Overview of the Unique Requirements and Challenges for ...](https://reader034.fdocuments.in/reader034/viewer/2022052017/6286697f8d69b56d130e1a43/html5/thumbnails/14.jpg)
Advanced Components & Systems Division
Medium Voltage Power Electronic Components
Thank you