Outdoor - LED Lighting, Controls and Daylighting Leader · CHE High Pressure Sodium Roadway...

47
Outdoor Roadway Lighting Family FileName Description RevisionDate Roadway CHE CHE-S Small, 35-150W HPS 12/30/2004 CHL CHL-M-S Low-wattage, 50-250W HPS, 175-250W MH 03/10/2008 CHLD CHLD-M-S Low-wattage, 50-250W HPS, 175-250W MH 02/29/2008 CHM CHM-M-S Medium-wattage, 200-400W HPS, 175-400W MH 03/10/2008 CHMD CHMD-M-S Low-wattage, power door, 200-400W HPS, 175-400W MH 02/29/2008 CHX CHX-M-S High-wattage, 310-1000W HPS, 1000W MH 02/29/2008 KDC KDC1-M-MV-S Low profile, 70-150W HPS, 175W MH and MV 11/02/2007 KDC KDC1-M-S Low profile, 70-150W HPS, 175W MH 08/14/2008 KDC2 KDC2-M-S Low profile, 200-400W HPS, 250-400W MH 02/29/2008 KML KML-L Flat polycarbonate, full cutoff, 55-180W LPS 09/20/2007 KP2 KP2-L 90-180W LPS 04/13/2005 KRP KRP-L Drop Lens Acrylic 90-180W LPS 04/13/2005 KRX KRX-L Die-cast aluminum 90-180 LPS 04/01/2006 KT1 KT1-L Cutoff 90 LPS 04/27/2006 TDR TDR-M-S Offset Direct, 200-400W HPS, 250-400W MH 02/29/2008 TDS2 TDS2-M-S 35-150W HPS, 70-175W MH 02/29/2008 TDS3 TDS3-M-S 200-400W HPS, 250-400W MH 02/29/2008 TDX TDX-S Roadway/Security Lighting 35-150W HPS 12/30/2004 TMM TMM-M-S Offset 200-400 HPS, 250-400 MH 02/29/2008 TSL TSL-M-MV-S Sign Lighting 70-400W HPS and MH, 100-400W MV 02/29/2008 TSL TSL-M-S Sign Lighting 70-400W HPS and MH 08/14/2008 TW5-TW6 TW5-M-S Underpass/Tunnel, 70-250W HPS and MH 02/29/2008 TW5-TW6 TW6-M-S Vandal resistant, 70-250W HPS and MH 02/29/2008

Transcript of Outdoor - LED Lighting, Controls and Daylighting Leader · CHE High Pressure Sodium Roadway...

OutdoorRoadway Lighting

Family FileName Description RevisionDate

RoadwayCHE CHE-S Small, 35-150W HPS 12/30/2004

CHL CHL-M-S Low-wattage, 50-250W HPS, 175-250W MH 03/10/2008

CHLD CHLD-M-S Low-wattage, 50-250W HPS, 175-250W MH 02/29/2008

CHM CHM-M-S Medium-wattage, 200-400W HPS, 175-400W MH 03/10/2008

CHMD CHMD-M-S Low-wattage, power door, 200-400W HPS, 175-400W MH 02/29/2008

CHX CHX-M-S High-wattage, 310-1000W HPS, 1000W MH 02/29/2008

KDC KDC1-M-MV-S Low profile, 70-150W HPS, 175W MH and MV 11/02/2007

KDC KDC1-M-S Low profile, 70-150W HPS, 175W MH 08/14/2008

KDC2 KDC2-M-S Low profile, 200-400W HPS, 250-400W MH 02/29/2008

KML KML-L Flat polycarbonate, full cutoff, 55-180W LPS 09/20/2007

KP2 KP2-L 90-180W LPS 04/13/2005

KRP KRP-L Drop Lens Acrylic 90-180W LPS 04/13/2005

KRX KRX-L Die-cast aluminum 90-180 LPS 04/01/2006

KT1 KT1-L Cutoff 90 LPS 04/27/2006

TDR TDR-M-S Offset Direct, 200-400W HPS, 250-400W MH 02/29/2008

TDS2 TDS2-M-S 35-150W HPS, 70-175W MH 02/29/2008

TDS3 TDS3-M-S 200-400W HPS, 250-400W MH 02/29/2008

TDX TDX-S Roadway/Security Lighting 35-150W HPS 12/30/2004

TMM TMM-M-S Offset 200-400 HPS, 250-400 MH 02/29/2008

TSL TSL-M-MV-S Sign Lighting 70-400W HPS and MH, 100-400W MV 02/29/2008

TSL TSL-M-S Sign Lighting 70-400W HPS and MH 08/14/2008

TW5-TW6 TW5-M-S Underpass/Tunnel, 70-250W HPS and MH 02/29/2008

TW5-TW6 TW6-M-S Vandal resistant, 70-250W HPS and MH 02/29/2008

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Example: CHE 100S R2 DLG 120 PER LPI

FEATURES & SPECIFICATIONSINTENDED USE

Ideal for lighting roadways, residential streets, storage areas, parking lotscampuses and parks.

CONSTRUCTION

Stainless Steel latch enables easy opening with one hand for relamping andservicing. Large surface area “breathing-seal” polyester gasketingprotects reflector and lens from contaminants; maintains maximum opticalefficiency. Gray polyester powder paint finish is electrostatically applied forsuperior corrosion resistance. Twist-lock photocontrol receptacle NOTincluded as standard ( To order specify PER option, SEE BELOW)

ELECTRICAL

Reactor, normal power factor ballast standard. High power factor available.(See options.) Two- or three-position (L1, L2, N) tunnel type compressionterminal block standard.

OPTICAL SYSTEMS

Ovate refractors in a variety of materials or flat tempered glass full cutofflens provides a choice of efficient light distributions for every application.Optics are computer designed for maximum performance.

INSTALLATION

Two bolt mast arm mount. Arm compatible for 1.25” - 2.0” (3.2cm - 5.1 cm)mast arm.

LISTING

IP32 rated housing and IP54 rated optical assembly is standard. IP65 ratingis available for optical assembly, see options. Standard product is NOT listedby UL, CSA or NOM.

Series

CHE

Distribution

R2R3

Outdoor

Catalog Number

Notes Type

Standard dimensions

(dimensions do not includemounting arm)

Flat Lens EPA: .61 ft2 (.057m2)Drop Lens EPA: .77 ft2 (.072 m2)

Length: 21” (53.3)Width: 12-7/8” (32.7)

Flat Lens Depth: 6-7/8” (12.5)Drop Lens Depth: 10-1/2” (26.7)

Weight: 12 lbs. (5.4 kg)

Wattage/LampSource

35S1

50S70S

100S150S

Lens

DLG Drop lens glass(standard)

DLA Drop lens acrylic2

DLP Drop lenspolycarbonate2

FL Flat temperedglass lens, fullcutoff

SLG Sag lens glass

Voltage

120L/E3

Ballast Options

(blank) Reactor normalpower factor(standard)

RHP Reactor highpower factor

Options

Shipped Installed in FixtureLPI Lamp included as standard

L/LP Less lampPER NEMA twist-lock receptacle

only (photocontrol notincluded).

PEU NEMA twist-lock PEDPL Distribution pattern labelT2P Terminal block- two position

wired L1 L2HSS Stainless steel external

hardware

Shipped Separately4

SC Shorting cap for PER option

Notes:1 Not available with RHP.2 Available with R2 distribution only.3 Shipped without ballast/electrical compo-

nents.4 May be ordered as an accessory.

CHE

All dimensions are inches (centimeters) unlessotherwise noted.

Roadway Lighting

CHE35-150W HIGH PRESSURE SODIUM

Sheet #: CHE-S RL-100

CHE High Pressure Sodium Roadway Lighting

Lithonia LightingAcuity Lighting Group, Inc.Outdoor LightingOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209In Canada: 160 avenue Labrosse, Pointe-Claire, P.Q. H9R 1A1www.lithonia.com ©2001 Acuity Lighting Group, Inc., Rev. 12/04Sheet #: CHE-S

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Example: CHL 150S R2 DLG 120 PER LPI

FEATURES & SPECIFICATIONSINTENDED USE

Ideal for lighting roadways, residential streets, storage areas, parking lots,campuses and parks.

CONSTRUCTION

Die-cast trigger latch located on lower housing , enables easy opening withone hand for relamping and servicing. Large surface area “breathing-seal”polyester gasketing protects reflector and lens from contaminants;maintains maximum optical efficiency. Die-cast low copper aluminum alloyfor light weight, strength and reliable service. Gray polyester powder paintfinish is electrostatically applied for superior corrosion resistance. Twist-lock photocontrol receptacle NOT included as standard (To order specifyPER option, SEE BELOW)

ELECTRICAL

Lag, high power factor (HPS) or constant wattage autotransformer (MH)standard. Two- or three-position (L1, L2, N) tunnel type compressionterminal block standard.

OPTICAL SYSTEMS

Ovate refractor or full cut-off flat lens styles provide a choice of efficientlight distributions for every application. Optics are computer designed formaximum performance. One-piece screw shell socket provides positiveretention of lamp under vibration.

INSTALLATION

Two-bolt mast-arm mount with integral stepped leveling system providessecure mounting and ease of leveling.

LISTING

IP64 rated optical assembly. IP65 rating is available, see options. Standardproduct is NOT listed by UL, CSA or NOM.

Series

CHL

Outdoor

Standard dimensions

(dimensions do not include mounting arm)

Flat Lens EPA: .74 ft2 (.07m2)Drop Lens EPA: .90 ft2 (.08 m2)

Length: 27” (66.6)Width: 13” (33.0)

Flat Lens Depth: 6-1/2” (16.5)Drop Lens Depth: 10-1/8” (25.7)

Weight: 29 lbs. (13.2 kg)

Wattage/lampsource

High pressuresodium

50S70S

100S150S250S

100/150S150/100S

Metal halide175M250M

NOTES:1 150S, 175M max.2 HPS only. 150-watt max with R3. 250-watt max with R2.3 Optional multi-tap ballast (120, 208, 240, 277V). TB

prewired to 277V. Others are: 1=120V; 2=208V; 3=240V.4 N/A with RNP or RHP.5 Consult factory.6 Shipped without ballast/electrical components.

CHL

All dimensions are inches (centimeters) unlessotherwise noted.

Roadway Lighting

CHL50-250W HIGH PRESSURE SODIUM

175-250W METAL HALIDE

Sheet #: CHL-M-S RL-110

7 Pulse start MH only8 HPS only9 120, 277V only. Not available in TB.10 208, 240, 480V only. Not available in TB.11 May be ordered as an accessory.

Distribution

R2R3

Lens

DLG Drop lens glass(standard)

DLA Drop lens acrylicDLP Drop lens

polycarbonate1

FL Flat temperedglass lens2

FLX Flat temperedglass lens, highperformance2

SLG Sag lens glass

Voltage

120208240277480

TB3,4

TB13,4

TB23,4

TB33,4

120/2405

240/1205

240/4805

480/2405

L/E6

Ballast

(blank) Standard ballast (seeabove)

RNP Reactor normal powerfactor

RHP Reactor high powerfactor

50HZ 50 hertz.MRB Mag Reg ballastCWI CWI ballast

CWA Constant wattageautotransformer

XHP High reactance (lag)high power factor8

XNP High reactance (lag)normal power factor8

NOTE: SCWA ballast must be selectedto comply with California Title 20metal halide regulations. SCWA alsomay be required to meet other states'regulations. Consult local authoritIes.SCWA SCWA pulse-start

Options

Shipped Installed in FixtureLPI Lamp included

L/LP Less lampPER NEMA twist-lock

receptacle only(photocontrol notincluded)

PEU NEMA twist-lock PECF Charcoal filter

BLV Bubble level4BM 4-bolt mounting

2EF External fitter (2-boltonly)

MA2 2-bolt internal 2”pipe setting

OPS Open plug-in starter8

ENP Encapsulated plug-in starter8

DPL Distribution patternlabel

T2P Terminal block-twoposition wired L1 L2

T3P Terminal block-threeposition wired L1, N,L2

UL UL Listed5

CSA CSA listed5

HSS Stainless steelexternal hardware

LSA Single lighteningsurge arrestor9

SF Single 5-amp fuse9

DF Double 5-amp fuse10

DDB Dark bronze finishDBL Black finish

Shipped Separately11

SC Shorting cap forPER option

Catalog Number

Notes Type

CHL High Pressure Sodium and Metal Halide Roadway Lighting

Sheet #: CHL-M-S ©2001 Acuity Brands Lighting, Inc., Rev. 2/29/08

Lithonia LightingOutdoorOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209www.lithonia.com

FEATURES & SPECIFICATIONSINTENDED USE

Ideal for lighting roadways, residential streets, storage areas, parking lots,shopping centers, apartment and condo complexes, campuses and parks.

CONSTRUCTION

All major electrical components mounted on removable power door for easeof field servicing and maintenance. Die-cast trigger latch located on lowerhousing, enables easy opening with one hand for relamping and servicing.Large surface area “breathing-seal” polyester gasketing protects reflectorand lens from contaminants; maintains maximum optical efficiency. Die-castlow copper aluminum alloy for light weight, strength and reliable service. Graypolyester powder paint finish is electrostatically applied for superiorcorrosion resistance. Twist-lock photocontrol receptacle NOT included asstandard (To order specify PER option, SEE BELOW)

ELECTRICAL

Lag, high power factor (HPS) or constant wattage autotransformer (MH)standard. Two- or three-position (L1, L2, N) tunnel type compressionterminal block standard.

OPTICAL SYSTEMS

Ovate refractor or full cut-off flat lens styles provide a choice of efficientlight distributions for every application. Optics are computer designed formaximum performance. One-piece screw shell socket provides positiveretention of lamp under vibration.

INSTALLATIONTwo-bolt mast-arm mount with integral stepped levelingsystem provides secure mounting and ease of leveling.

LISTING

IP64 rated optical assembly. IP65 rating is available, see options. Standardproduct is NOT listed by UL, CSA or NOM.

Outdoor

Standard dimensions

(dimensions do not includemounting arm)

Flat Lens EPA: .74 ft2 (.07m2)Drop Lens EPA: .90 ft2 (.08 m2)

Length: 27” (66.6)Width: 13” (33.0)

Flat Lens Depth: 6-1/2” (16.5)Drop Lens Depth: 10-1/8” (25.7)

Weight: 33 lbs. (15 kg)All dimensions are inches (centimeters) unless otherwise noted.

Roadway Lighting

CHLD50-250W HIGH PRESSURE SODIUM

175-250W METAL HALIDE

Sheet #: CHLD-M-S RL-120

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs and write it on the appropriate line.Order accessories as separate catalog number.

Example: CHLD 150S R2 DLG 120 PER LPI

Series

CHLD

Distribution

R2R3

Wattage/lampsource

High pressuresodium

50S70S

100S100/150S150/100S

150S250S

Metal halide175M250M

Lens

DLG Drop lens glass(standard)

DLA Drop lens acrylicDLP Drop lens

polycarbonate1

FL Flat temperedglass lens2

FLX Flat temperedglass lens, highperformance2

SLG Sag lens glass

Voltage

120208240277480

TB3,4

TB13,4

TB23,4

TB33,4

120/2405

240/1205

240/4805

480/2405

L/E6

Ballast

(blank) Standard ballast (seeabove)

RNP Reactor normal powerfactor

RHP Reactor high powerfactor

50HZ 50 hertz.MRB Mag Reg ballastCWI CWI ballast

CWA Constant wattageautotransformer

XHP High reactance (lag)high power factor8

XNP High reactance (lag)normal power factor8

NOTE: SCWA ballast must be selectedto comply with California Title 20metal halide regulations. SCWA alsomay be required to meet other states'regulations. Consult local authoritIes.SCWA SCWA pulse-start

NOTES:1 150S, 175M max.2 HPS only. 150 watt max with R3. 250 watt max with R2.3 Optional multi-tap ballast (120, 208, 240, 277V). TB

prewired to 277V. Others are: 1=120V; 2=208V; 3=240V.4 N/A with RNP or RHP.5 Consult factory.6 Shipped without ballast/electrical components.7 Pulse start MH only8 HPS only

CHLD

Options

9 120, 277V only. Not available in TB.10 208, 240, 480V only. Not available in TB.11 May be ordered as an accessory.

Shipped Installed in FixtureLPI Lamp included

L/LP Less lampPER NEMA twist-lock

receptacle only(photocontrol notincluded)

PEU NEMA twist-lock PECF Charcoal filter

BLV Bubble level4BM 4-bolt mounting

2EF External fitter (2-boltonly)

MA2 2-bolt internal 2”pipe setting

OPS Open plug-in starter8

ENP Encapsulated plug-in starter8

DPL Distribution patternlabel

Catalog Number

Notes Type

T2P Terminal block-twoposition wired L1 L2

T3P Terminal block-threeposition wired L1, N,L2

UL UL Listed5

CSA CSA listed5

HSS Stainless steelexternal hardware

LSA Single lighteningsurge arrestor9

SF Single 5-amp fuse9

DF Double 5-amp fuse10

DDB Dark bronze finishDBL Black finish

Shipped Separately11

SC Shorting cap forPER option

CHLD High Pressure Sodium and Metal Halide Roadway Lighting

Sheet #: CHLD-M-S ©2001 Acuity Brands Lighting, Inc., Rev. 2/29/08

Lithonia LightingOutdoorOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209www.lithonia.com

Catalog Number

Notes Type

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Example: CHM 400S R2 DLG 120 PER LPI

FEATURES & SPECIFICATIONSINTENDED USEIdeal for lighting roadways, residential streets, storage areas, parking lots,shopping centers, apartment and condo complexes, campuses and parks.CONSTRUCTIONDie-cast trigger latch located on lower housing , enables easy opening withone hand for relamping and servicing. Large surface area “breathing-seal”polyester gasketing protects reflector and lens from contaminants; main-tains maximum optical efficiency. Die-cast low copper aluminum alloy forlight weight, strength and reliable service. Gray polyester powder paintfinish is electrostatically applied for superior corrosion resistance. Twist-lock photocontrol receptacle NOT included as standard ( To order specifyPER option, SEE BELOW)ELECTRICALConstant wattage autotransformer standard. Two- or three-position (L1, L2, N)tunnel type compression terminal block standard.OPTICAL SYSTEMSOvate refractor or full cut-off flat lens styles provide a choice of efficient lightdistributions for every application. Optics are computer designed for maxi-mum performance. One-piece screw shell socket provides positive reten-tion of lamp under vibration.INSTALLATIONFour bolt mast arm mount for the most secure mounting in the industry.LISTINGIP64 rated optical assembly. IP65 rating is available, see options. Standardproduct is NOT listed by UL, CSA or NOM.

Series

CHM

Outdoor

NOTES:1 May be ordered with SCWA.2 Must be ordered with SCWA.3 250-watt max MH 400-watt maxHPS4 HPS only.5 Optional multi-tap ballast (120, 208, 240, 277V). TB

prewired to 277V. Others are: 1=120V; 2=208V; 3=240V.

CHM

Standard dimensions(dimensions do not include mounting arm)

Flat lens EPA: 1.14 ft2 (.11m2)Drop lens EPA: 1.3 ft2 (.12 m2)

Length: 31-1/2 (80.0)Width: 14-3/4 (37.5)

Flat lens depth: 7-1/2 (19.1)Drop lens depth: 14 (35.6)

Weight: 41 lbs. (18.6 kg)

Roadway Lighting

CHM200-400W HIGH PRESSURE SODIUM

175-400W METAL HALIDE

Sheet #: CHM-M-S RL-130

6 Shipped without ballast/electrical components.7 Consult factory.8 Available in 120 and 277 volt only.9 Available in 208, 240, 480 volt only.10 May be ordered as an accessory.

Wattage/lamp source

High pressure sodium200S250S310S

250/400S400S/250S

400SMetal halide

175M250M1

250/400M400/250M

320M2

350M2

400M1

Distribution

R2R3

Lens

DLG Drop lensglass(standard)

DLA Drop lensacrylic

DLP Drop lenspolycarbon-ate3

FL Flat temperedglass lens3

FLX Flat temperedglass lens,highperformance4

SLG Sag lens glass

Voltage

120208240277480TB5

TB15

TB25

TB35

L/E6

Options

Shipped installed in fixtureLPI Lamp included

L/LP Less lampPER NEMA twist-lock

receptacle only(photocontrol notincluded)

PEU NEMA twist-lock PECF Charcoal filter

BLV Bubble level2BM 2-bolt mountingOPS Open plug-in starter4

ENP Encapsulated plug-in starter4

DPL Distribution patternlabel

T2P Terminal block-twoposition wired L1 L2

T3P Terminal block-three position wiredL1, N, L2

UL UL Listed7

CSA CSA listed7

HSS Stainless steelexternal hardware

LSA Single lighteningsurge arrestor8

SF Single 5-amp fuse8

DF Double 5-amp fuse0

DDB Dark bronze finishDBL Black finish

Shipped Separately10

SC Shorting cap forPER option

Ballast

(blank) Constant wattageautotransformer

RNP Reactor normal powerfactor

RHP Reactor high powerfactor4

50HZ 50 hertz.MRB Mag Reg ballastCWI CWI ballastXHP High reactance (lag)

high power factorXNP High reactance (lag)

normal power factor

NOTE: SCWA ballst must be selectedto comply with California Title 20metal halide regulations. SCWA alsomay be required to meet other states'regulations. Consult local authoritIes.SCWA SCWA pulse-start

Lithonia LightingOutdoorOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209www.lithonia.com

CHM High Pressure Sodium and Metal Halide Roadway Lighting

Sheet #: CHM-M-S ©2001 Acuity Brands Lighting, Inc., Rev. 8/14/08

Catalog Number

Notes Type

FEATURES & SPECIFICATIONSINTENDED USE

Ideal for lighting roadways, residential streets, storage areas, parking lots,shopping centers, apartment and condo complexes, campuses and parks.

CONSTRUCTION

All major electrical components mounted on removable power door for easeof field servicing and maintenance. Die-cast trigger latch located on lowerhousing , enables easy opening with one hand for relamping and servicing.Large surface area “breathing-seal” polyester gasketing protects reflectorand lens from contaminants; maintains maximum optical efficiency. Die-castlow copper aluminum alloy for light weight, strength and reliable service. Graypolyester powder paint finish is electrostatically applied for superior corro-sion resistance. Twist-Lock photocontrol receptacle included as standard(less photocontrol receptacle option available).

ELECTRICAL

Constant wattage autotransformer standard. Two- or three-position (L1, L2, N)tunnel type compression terminal block standard.

OPTICAL SYSTEMS

Ovate refractor or full cut-off flat lens styles provide a choice of efficientlight distributions for every application. Optics are computer designed formaximum performance. One-piece screw shell socket provides positive re-tention of lamp under vibration.

INSTALLATION

Four bolt mast arm mount for the most secure mounting in the industry.

LISTING

IP64 rated optical assembly. IP65 rating is available, see options. Standardproduct is NOT listed by UL, CSA or NOM.

Outdoor

Standard dimensions

(dimensions do not includemounting arm)

Flat lens EPA: 1.14 ft2 (.11m2)Drop lens EPA: 1.3 ft2 (.12 m2)

Length: 31-1/2 (80.0)Width: 14-3/4 (37.5)

Flat lens depth: 7-1/2 (19.1)Drop lens depth: 14 (35.6)

Weight: 45 lbs. (20.4 kg)All dimensions are inches (centimeters) un-less otherwise noted.

Roadway Lighting

CHMD200-400W HIGH PRESSURE SODIUM

175-400W METAL HALIDE

Sheet #: CHMD-M-S RL-140

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Example: CHMD 400S R2 DLG 120 PER LPI

Series

CHMD

CHMD

Wattage/lamp source

High pressure sodium200S250S310S

250/400S400S/250S

400SMetal halide

175M250M1

250/400M400/250M

320M2

350M2

400M1

Distribution

R2R3

Lens

DLG Drop lensglass(standard)

DLA Drop lensacrylic

FL Flat temperedglass lens3

FLX Flat temperedglass lens,highperformance4

SLG Sag lens glass

Voltage

120208240277480TB5

TB15

TB25

TB35

L/E6

Options

Shipped installed in fixtureLPI Lamp included

L/LP Less lampPER NEMA twist-lock

receptacle only(photocontrol notincluded)

PEU NEMA twist-lock PECF Charcoal filter

BLV Bubble level2BM 2-bolt mountingOPS Open plug-in starter4

ENP Encapsulated plug-in starter4

DPL Distribution patternlabel

T2P Terminal block-twoposition wired L1 L2

T3P Terminal block-threeposition wired L1, N, L2

UL UL Listed7

CSA CSA listed7

HSS Stainless steelexternal hardware

LSA Single lighteningsurge arrestor8

SF Single 5-amp fuse8

DF Double 5-amp fuse9

DDB Dark bronze finishDBL Black finish

Shipped Separately10

SC Shorting cap forPER option

Ballast

(blank) Constant wattageautotransformer

RNP Reactor normal powerfactor4

RHP Reactor high powerfactor

50HZ 50 hertz.MRB Mag Reg ballastCWI CWI ballastXHP High reactance (lag)

high power factorXNP High reactance (lag)

normal power factor

NOTE: SCWA ballast must be selectedto comply with California Title 20metal halide regulations. SCWA alsomay be required to meet other states'regulations. Consult local authoritIes.SCWA SCWA pulse-start

NOTES:1 May be ordered with SCWA.2 Must be ordered with SCWA.3 250-watt max MH 400-watt maxHPS4 HPS only.5 Optional multi-tap ballast (120, 208, 240, 277V). TB

prewired to 277V. Others are: 1=120V; 2=208V; 3=240V.

6 Shipped without ballast/electrical components.7 Consult factory.8 Available in 120 and 277 volt only.8 Available in 208, 240, 480 volt only.10 May be ordered as an accessory.

Lithonia LightingOutdoorOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209www.lithonia.com

CHMD High Pressure Sodium and Metal Halide Roadway Lighting

Sheet #: CHMD-M-S ©2001 Acuity Brands Lighting, Inc., Rev. 8/14/08

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Example: CHX 400S R2 DLG 120 PER LPI

FEATURES & SPECIFICATIONSINTENDED USE

Ideal for lighting roadways, residential streets, storage areas, parkinglots,shopping centers, apartment and condo complexes, campuses andparks.

CONSTRUCTION

Die-cast trigger latch located on lower housing , enables easy opening withone hand for relamping and servicing. Large surface area “breathing-seal”polyester gasketing protects reflector and lens from contaminants; maintainsmaximum optical efficiency. Die-cast low copper aluminum alloy for light weight,strength and reliable service. Gray polyester powder paint finish is electro-statically applied for superior corrosion resistance. Twist-lock photocontrolreceptacle NOT included as standard (To order specify PER option, SEE BE-LOW)

ELECTRICAL

Constant wattage autotransformer standard. Two- or three-position (L1, L2,N) tunnel type compression terminal block standard.

OPTICAL SYSTEMS

Precision ovate refractor/reflector optics provide uniform distribution pat-tern, excellent luminaire to pole spacing. One-piece screw shell socket pro-vides positive retention of lamp under vibration.

INSTALLATION

Four bolt mast arm mount for the most secure mounting in the industry.

LISTING

Standard product is NOT listed by UL, CSA or NOM.

Series

CHX

Distribution

R21

R3

Outdoor

Standard dimensions

(dimensions do not includemounting arm)

EPA: 1.96 ft2 (.18m2)Length: 38-3/8” (97.5)

Width: 17-1/2” (44.5)Depth: 16-1/4” (41.3)

Weight: 76 lbs. (34.5 kg)

Wattage/lampsource

High pressuresodium

310S400S

1000SMetal halide

1000M`

Lens

DLG Drop lensglass(standard)

Voltage

120208240277480TB2

TB12

TB22

TB32

120/2403

240/4803

L/E4

Ballast

(blank) Standard CWACWI CWI ballast3

NOTE: SCWA ballast must beselected to comply withCalifornia Title 20 metal halideregulations. SCWA also may berequired to meet other states'regulations. Consult localauthoritIes.SCWA SCWA pulse-start5

NOTES:1 Not available in 1000 HPS2 Optional multi-tap ballast (120, 208, 240, 277V). TB prewired to 277V.

Others are: 1=120V; 2=208V; 3=240V.3 Consult factory4 Shipped without ballast/electrical components.5 Pulse-start MH only6 Available in 120 and 277 volt only.7 Available in 208, 240, 480 volt only.8 May be ordered as an accessory.

CHX

All dimensions are inches (centimeters) un-less otherwise noted.

Roadway Lighting

CHX310-1000W HIGH PRESSURE SODIUM

1000W METAL HALIDE

Sheet #: CHX-M-S RL-150

Options

Shipped Installed in FixtureLPI Lamp included as standard

L/LP Less lampPER NEMA twist-lock receptacle only

(photocontrol not included).PEU NEMA twist-lock PEBLV Bubble levelDPL Distribution pattern labelT2P Terminal block- two position wired

L1 L2T3P Terminal block- three position

wired L1, N, L2HSS Stainless steel external hardwareLSA Single lightning surge arrestor6

SF Single 5-amp fuse6

DF Double 5-amp fuse.7

DDB Dark bronze finishDBL Black finish

Shipped Separately8

SC Shorting cap for PER option

DLG

Catalog Number

Notes Type

CHX High Pressure Sodium and Metal Halide Roadway Lighting

Sheet #: CHX-M-S ©2001 Acuity Brands Lighting, Inc., Rev. 2/29/08

Lithonia LightingOutdoorOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209www.lithonia.com

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog numbers.

Example: KDC1 100S R2 DLG 120 RNP PER LPI

FEATURES & SPECIFICATIONSINTENDED USE

Architectural low profile ideal for lighting metropolitan roadways, residentialstreets, campus walkways, or for general area lighting in parking lots

CONSTRUCTION

Rugged die-cast aluminum housing and doorframe provide strength andcorrosion resistance. Standard doorframe can be easily opened with onehand without tools via die-cast latch. Large surface-area “breathing-seal”polyester gasketing protects reflector and lens from contaminants,maintaining maximum optical efficiency. Dark bronze polyester powderpaint finish is electrostatically applied for superior corrosion resistance.Available with or without twist-lock photocontrol receptacle.

ELECTRICAL

Constant wattage autotransformer ballasts are standard (other ballastsavailable). All electrical systems are 100% factory tested. Three-position (L1,L2, N) tunnel-type compression terminal block for supply connection isstandard.

OPTICAL SYSTEMS

Reflectors are high-efficiency hydroformed anodized aluminum deliveringprecise roadway distributions. A variety of lens/refractor media areavailable including flat tempered glass for full cutoff, drop glass prismaticrefractor, or drop prismatic refractor available in either acrylic orpolycarbonbate. Mogul-based screw shell socket is nickel plated brass andhas center-spring contact.

INSTALLATION

Two-bolt mast-arm mount with integral stepped leveling system providessecure mounting and ease of leveling.

LISTING

UL Listed. (Consult factory for CSA.)

Series

KDC1

Distribution

R2R3

Outdoor

Catalog Number

Notes Type

Standard dimensions(dimensions do not include mounting arm)

Flat lens EPA: 1.1 ft2 (.10m2)Drop lens EPA: 1.4 ft2 (.13m2)

Flat Lens Length: 23” (584)Flat Lens Width: 13.4” (340)Flat Lens Depth: 5.25” (128)

Weight: 26 lbs. (11.8 kg)

Wattage/lampsource

High pressuresodium

70S100S150S

Metal halide175M

Mercury vapor100MV175MV

Lens

DLG Drop lens glass(standard)

DLA Drop lensacrylic

DLP Drop lenspolycarbonate

FL Flat temperedglass lens, fullcutoff

Voltage

120208240277347480TB1

TB11

TB21

TB31

120/2402

240/1203

240/4803

480/2406

Ballast options

RNP Reactor normalpower factor4

RHP Reactor highpower factor4

XNP High reactance(lag) normalpower factor4

XHP High reactance(lag) high powerfactor4

50HZ 50 hertz; consultfactory

MRB Mag Reg ballastCWI CWI ballast

CWA Constantwattage auto-transformer

NOTES:1 Optional multi-tap ballast (120, 208, 240, 277V). TB

prewired to 277V. Others are: 1=120V; 2=208V; 3=240V.2 MV only, prewired to 120 volt.3 MV only, prewired to 240 volt.4 HPS only.5 Available in 208,240 and 480 volt only.6 MV only prewired to 480-volt

KDC1

All dimensions are inches (Millimeters) unlessotherwise noted.

Options

Shipped installed in fixture

LPI Lamp included as standardLPIC Coated lamp includedL/LP Less lampPER NEMA twist-lock receptacle only

(photocontrol not included).PEU NEMA twist-lock PE (277V)MA2 2-bolt internal 2” pipe settingOPS Open plug-in starterENP Encapsulated plug-in starterT2P Terminal block-two position wired L1 L2T3P Terminal block-three position wired L1, N, L2HSS Stainless steel external hardwareLSA Single lightning surge arrestor

SF Single 5-amp fuseDF Double 5-amp fuse5

MED Medium base socket(blank) Dark bronze finish (standard)

DBL Black finishDWH White finish

DGYG Gray finishShipped separately

SC Shorting cap for PER option

Roadway Lighting

KDC170-150W HIGH PRESSURE SODIUM

175W METAL HALIDE175W MERCURY VAPOR

Sheet #: KDC1-M-MV-S RL-160

23"(584)

13.4"(340)

8.25"(210)

FD

Mounting

(blank) Mast armSP12 12” direct

mountarm forsquarepole

KDC1 High Pressure Sodium, Metal Halide & Mercury Vapor Roadway Lighting

Lithonia LightingOutdoor LightingOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209www.lithonia.com ©2004 Acuity Brands Lighting, Inc. 11/2/07Sheet #: KDC1-M-MV-S

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

150W high pressure sodium lamp, rated 16000lumens. Footcandle values based on 20'mounting height.Classification: Type II, Medium, Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.51.5

1

0.5

0.25

TEST NO: LTL13161RKDC1 150S R2 DLA

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

150W high pressure sodium lamp, rated 16000lumens. Footcandle values based on 20'mounting height.Classification: Type III, Medium, Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

2.51.5

1

0.5

0.25

TEST NO: LTL13162RKDC1 150S R3 DLP

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

150W high pressure sodium lamp, rated 16000lumens. Footcandle values based on 20'mounting height.Classification: Type III, Medium, Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.51.5

10.5

0.25

TEST NO: LTL13163RKDC1 150S R3 FL

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

150W High pressure sodium lamp, rated 16000lumens. Footcandle values based on 20'mounting height.Classification: Type II, Medium, Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.51.5

10.5

0.25

TEST NO: LTL13164RKDC1 150S R2 FL

Catalog Number

Notes Type

Example: KDC1 100S R2 DLG 120 RNP PER LPI

FEATURES & SPECIFICATIONSINTENDED USEArchitectural low profile ideal for lighting metropolitan roadways, residen-tial streets, campus walkways, or for general area lighting in parking lotsCONSTRUCTIONRugged die-cast aluminum housing and doorframe provide strength andcorrosion resistance. Standard doorframe can be easily opened with onehand without tools via die-cast latch. Large surface-area “breathing-seal”polyester gasketing protects reflector and lens from contaminants, main-taining maximum optical efficiency. Dark bronze polyester powder paintfinish is electrostatically applied for superior corrosion resistance. Avail-able with or without twist-lock photocontrol receptacle.ELECTRICALConstant wattage autotransformer ballasts are standard (other ballasts avail-able). All electrical systems are 100% factory tested. Three-position (L1, L2, N)tunnel-type compression terminal block for supply connection is standard.OPTICAL SYSTEMSReflectors are high-efficiency hydroformed anodized aluminum deliveringprecise roadway distributions. A variety of lens/refractor media are avail-able including flat tempered glass for full cutoff, drop glass prismatic refrac-tor, or drop prismatic refractor available in either acrylic or polycarbonbate.Mogul-based screw shell socket is nickel plated brass and has center-spring contact.INSTALLATIONTwo-bolt mast-arm mount with integral stepped leveling system providessecure mounting and ease of leveling.LISTINGUL Listed. (Consult factory for CSA.)

Outdoor

Standard dimensions(dimensions do not include mounting arm)

Flat lens EPA: 1.1 ft2 (.10m2)Drop lens EPA: 1.4 ft2 (.13m2)

Flat lens length: 23 (584)Flat lens width: 13.4 (340)Flat lens depth: 5.25 (128)

Weight: 26 lbs. (11.8 kg)

All dimensions are inches (Millimeters) unless otherwise noted.

Roadway Lighting

KDC170-150W HIGH PRESSURE SODIUM

175W METAL HALIDE

Sheet #: KDC1-M-S RL-160

23(58.4)

13-3/8

8-1/4(21.0)

(34.0)

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs and write it on theappropriate line. Order accessories as separate catalog numbers (shipped separately).

Series

KDC1

KDC1

Wattage/lampsource

High pressuresodium

70S100S150S

Metal halide175M

Distribution

R2R3

Lens

DLG Drop lens glass(standard)

DLA Drop lensacrylic

DLP Drop lenspolycarbonate

FL Flat temperedglass lens, fullcutoff

Options

Shipped installed in fixtureLPI Lamp included as standard

LPIC Coated lamp includedL/LP Less lampPER NEMA twist-lock receptacle only

(photocontrol not included)PEU NEMA twist-lock PE (277V)MA2 2-bolt interanal 2” pipe settingOPS Open plug-in starterENP Encapsulated plug-in starterT2P Terminal block-two position

wired L1, L2T3P Terminal block-three position

wired L1, N, L2HSS Stainless steel external hardwareLSA Single lightning surge arrestor

SF Single 5-amp fuseDF Double 5-amp fuse3

MED Medium base socket(blank) Dark bronze finish (standard)

DBL Black finishDWH White finish

DGYG Gray finishShipped separately

SC Shorting cap for PER option

Ballast

(blank) Constant wattageautotransformer

RNP Reactor normalpower factor2

RHP Reactor high powerfactor2

XNP High reactancenormal power factor2

XHP High rectance (lag)high power factor2

50HZ 50 hertz. Consultfactory.

MRB Mag Reg ballastCWI CWI ballast

NOTE: SCWA ballast must beselected to comply with CaliforniaTitle 20 metal halide regulations.SCWA also may be required to meetother states' regulations. Consultlocal authoritIes.

SCWA SCWA pulse-start

Mounting

(blank) Mast armSP12 12” direct-

mountarm forsquarepole

Voltage

120208240277347480TB1

TB11

TB21

TB31

NOTES:1 Optional multi-tap ballast (120, 208, 240, 277V). TB

prewired to 277V. Others are: 1=120V; 2=208V; 3=240V.2 HPS only.3 Available in 208,240 and 480 volt only.

Lithonia LightingOutdoorOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209www.lithonia.com

KDC1 High Pressure Sodium and Metal Halide Roadway Lighting

©2004 Acuity Brands Lighting, Inc., Rev. 8/14/08Sheet #: KDC1-M-S

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

150W high pressure sodium lamp, rated 16000lumens. Footcandle values based on 20'mounting height.Classification: Type II, Medium, Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.51.5

1

0.5

0.25

TEST NO: LTL13161RKDC1 150S R2 DLA

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

150W high pressure sodium lamp, rated 16000lumens. Footcandle values based on 20'mounting height.Classification: Type III, Medium, Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

2.51.5

1

0.5

0.25

TEST NO: LTL13162RKDC1 150S R3 DLP

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

150W high pressure sodium lamp, rated 16000lumens. Footcandle values based on 20'mounting height.Classification: Type III, Medium, Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.51.5

10.5

0.25

TEST NO: LTL13163RKDC1 150S R3 FL

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

150W High pressure sodium lamp, rated 16000lumens. Footcandle values based on 20'mounting height.Classification: Type II, Medium, Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.51.5

10.5

0.25

TEST NO: LTL13164RKDC1 150S R2 FL

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Example: KDC2 200S R2 DLG 120 RNP PER LPI

FEATURES & SPECIFICATIONSINTENDED USEArchitectural low profile ideal for lighting metropolitan roadways, residentialstreets, campus walkways, or for general area lighting in parking lotsCONSTRUCTION

Rugged die-cast aluminum housing and doorframe provide strength andcorrosion resistance. Standard doorframe can be easily opened with onehand without tools via die-cast latch. Large surface-area “breathing-seal”polyester gasketing protects reflector and lens from contaminants,maintaining maximum optical efficiency. Dark bronze polyester powderpaint finish is electrostatically applied for superior corrosion resistance.Available with or without twist-lock photocontrol receptacle.ELECTRICALConstant wattage autotransformer ballasts are standard (other ballastsavailable). All electrical systems are 100% factory tested. Three-position (L1,L2, N) tunnel-type compression terminal block for supply connection isstandard.OPTICAL SYSTEMS

Reflectors are high-efficiency hydroformed anodized aluminum deliveringprecise roadway distributions. A variety of lens/refractor media areavailable including flat tempered glass for full cutoff, drop glass prismaticrefractor, or drop prismatic refractor available in either acrylic orpolycarbonbate. Mogul-based screw shell socket is nickel plated brass andhas center-spring contact.INSTALLATION

Two-bolt mast-arm mount with integral stepped leveling system providessecure mounting and ease of leveling.LISTING

UL listed. (Consult factory for CSA)

Outdoor

Standard dimensions(dimensions do not include mounting arm)

Flat Lens EPA: 1.8 ft2 (.17m2)Drop Lens EPA: 2.1 ft2 (.20m2)

Length: 27.1” (689)Width: 17” (450)

Flat Lens Depth: 8.25” (201)Weight: 45 lbs. (20.4 kg)

NOTES:1 400M requires reduced-envelope ED28 lamp.2 Optional multi-tap ballast (120, 208, 240, 277V). TB

prewired to 277V. Others are: 1=120V; 2=208V; 3=240V.3 HPS only4 Available in 208, 240, 480 volt only.

All dimensions are inches (millimeters) unless otherwise noted.

Roadway Lighting

KDC2200-400W HIGH PRESSURE SODIUM

250-400W METAL HALIDE

Sheet #: KDC2-M-S RL-170

27.1"(689)

17"(432)

8.2"(209)

FD

Catalog Number

Notes Type

Series

KDC2

KDC2

Wattage/lampsource

High pressuresodium

200S250S310S

250/400S400/250S

400SMetal halide

250M320M350M400M

Distribution

R2R3

Lens

DLG Drop lens glass(standard)

DLA Drop lens acrylicDLP Drop lens

polycarbonateFL Flat tempered

glass lens, fullcutoff1

Voltage

120208240277347480TB2

TB12

TB22

TB32

Options

Shipped Installed in FixtureLPI Lamp included

LPIC Coated lampincluded

L/LP Less lampPER NEMA twist-lock

receptacle only(photocontrol notincluded)

PEU NEMA twist-lock PEMA2 2-bolt interanal 2”

pipe settingOPS Open plug-in

starterENP Encapsulated

plug-in starterT2P Terminal block-two

position wired L1 L2

T3P Terminal block-three positionwired L1, N, L2

HSS Stainless steelexternal hardware

LSA Single lighteningsurge arrestor

SF Single 5-amp fuseDF Double 5-amp

fuse4

(blank) Dark bronze finish(standard)

DBL Black finishDWH White finish

DGYG Gray finishShipped Separately

SC Shorting cap forPER option

Ballast

(blank) Standard ballast (seeabove)

RNP Reactor normal powerfactor3

RHP Reactor high powerfactor3

XNP High reactance (lag)normal power factor3

XHP High reactance (lag)high power factor3

50HZ 50 hertz, consult factoryMRB Mag Reg ballastCWI CWI ballast

CWA Constant wattageautotransformer

NOTE: SCWA ballast must be selectedto comply with California Title 20metal halide regulations. SCWA alsomay be required to meet other states'regulations. Consult local authoritIes.SCWA SCWA pulse-start

KDC2 High Pressure Sodium and Metal HalideRoadway Lighting

Sheet #: KDC2-M-S

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

400W high pressure sodium lamp, rated 50000lumens. Footcandle values based on 20'mounting height.Classification: Type III, Medium, Noncutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.51.5

10.5

TEST NO: LTL13153RKDC2 400S R3 DLP

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

400W high pressure sodium lamp, rated 50000lumens. Footcandle values based on 20'mounting height.Classification: Type III, Medium, Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.51.5

1

0.5

0.25

TEST NO: LTL13157RKDC2 400S R3 FL

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

400W high pressure sodium lamp, rated 50000lumens. Footcandle values based on 30'mounting height.Classification: Type III, Medium, Noncutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.5

1.51

0.50.25

TEST NO: LTL13151RKDC2 400S R3 DLA

©2004 Acuity Brands Lighting, Inc., Rev. 2/29/08

Lithonia LightingOutdoorOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209www.lithonia.com

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Example: KML 90L R1 120 LPI PER

Series

KML

Distribution

R1

Outdoor

Catalog Number

Notes Type

Wattage/lampsource

55L90L

135L180L

Lens

(blank) Flat polycar-bonate , fullcutoff

Voltage

120208240277347480

120/2401

208/2772

Ballast options

(blank) Standard ballast(see above)

RHP Reactor highpower factor3

Options

Shipped installed in fixture

LPI Lamp included as standardPER NEMA twist-lock recep-

tacle only (photocontrolnot included).

PE1 NEMA twist-lock PE (120,208, 240V)

PE4 NEMA twist-lock PE (480V)PE7 NEMA twist-lock PE (277V)

(blank) Dark bronze (standard)DBL Black finish

DWH White finishDGYG Gray finish

Notes:1 Wired 120V.2 Wired 208V, 90L only3 480V only

KML

Area/Roadway Lighting

KML55-180W LOW PRESSURE SODIUM

Sheet #: KML-L AL-415

R1

FEATURES & SPECIFICATIONSINTENDED USE

Designed for maximum energy savings with efficient light distribution forgeneral roadway and area lighting where classic architectural appear-ance is desired

CONSTRUCTION

Housing and doorframe are durable formed and welded aluminum, powdercoated for maximum durability.

ELECTRICAL

Standard ballast is high reactance (lag), high power factor. Reactor highpower factor ballast is available (90W only)

OPTICAL SYSTEMS

Flat polycarbonate refractor provides maximum control of light distributionand increased vandal resistance. Large surface area “breathing seal”gasket seals the optical chamber to prevent intrusion by insects andenvironmental contaminants. Heat-resistant gasket material remainseffective over the life of the fixture.

INSTALLATION

Mast arm mount provides easy, secure installation and adjustability for armsfrom 1-1/4” to 2” (32mm to 51mm) mast arms.

LISTING

Standard product is listed by UL, CSA, or NOM. For listing availability, consultfactory. Complies with ANSI: C136.2, C136.10, C136.15

Standard dimensions(dimensions do not include mounting arm)

55-90W 135W 180W

EPA: 2.83 ft2 3.78 ft2 5.00 ft2

Length: 30” 40” 53-1/2”Width: 14-3/8” 14-3/8” 14-3/8”Depth: 8” 8” 8”

Weight: 45 lbs. (20.4kg) 45 lbs. (20.4kg) 45 lbs. (20.4kg)

KML Low Pressure Sodium Area/Roadway Lighting

Lithonia LightingOutdoor LightingOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209www.lithonia.com ©2004 Acuity Brands Lighting, Inc. 9/20/07Sheet #: KML-L

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

90W low pressure sodium lamp, rated 13500lumens. Footcandle values based on 20'mounting height.Classification: Unclassified (Type II, Very Short), Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.51.5

1

0.5

0.25

TEST NO: LTL13215RKML 90L R2 FL

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

135W low pressure sodium lamp, rated 21500lumens. Footcandle values based on 20'mounting height.Classification: Unclassified (Type II, Very Short), Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.51.5

1

0.5

0.25

TEST NO: LTL13216RKML 135L R2 FL

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

180W low pressure sodium lamp, rated 33000lumens. Footcandle values based on 20'mounting height.Classification: Unclassified (Type II, Very Short), Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.51.5

1

0.5

0.25

TEST NO: LTL13217RKML 180L R2 FL

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Example: KP2 135L R4 DLA 120 PER LPI

FEATURES & SPECIFICATIONSINTENDED USE

Designed for maximum energy savings with efficient light distribution forgeneral roadway and area lighting. Ideal for coastal areas or anywherecorrosion is a concern.

CONSTRUCTION

Outer housing is constructed of non-corrosive ABS composite plastic withUV-inhibiting coating for long life in demanding environments.

ELECTRICAL

Standard ballast is high reactance (lag), high power factor. Reactor highpower factor ballast is available (90W only).

OPTICAL SYSTEMS

Drop prismatic acrylic refractor allows for maximum control of lightdistribution. Optional prismatic polycarbonate refractor available forincreased vandal resistance. Large surface area “breathing seal” gasketseals the optical chamber to prevent intrusion by insects and environmen-tal contaminants. Heat-resistant gasket material remains effective over thelife of the fixture.

INSTALLATION

Mast-arm mount provides easy, secure installation and adjustability forarms from 1-1/4” to 2” (32mm to 51mm) mast arms.

LISTING

Standard product is NOT listed by UL, CSA or NOM. For listing availability,consult factory. Complies with ANSI: C136.2, C136.10, C136.15

Series

KP2

Distribution

R4

Outdoor

Catalog Number

Notes Type

Standard dimensions(dimensions do not include mounting arm)

KP2 EPA: 1.45 ft2 (.13m2)Length: 63 7/16” (1611)Weight: 37 lbs. (16.8kg)

Wattage/LampSource

90L135L180L

Lens

DLA Drop lensacrylic

DLP Drop lenspolycarbonate

Voltage

120208240277347480

208/2772

277/2081

Ballast Options

(blank) Standard ballast(see above)

RHP Reactor highpower factor3

Shipped Installed in FixtureLPI Lamp included as

standardPER NEMA twist-lock

receptacle only(photocontrol notincluded).

PEU NEMA twist-lock PE(blank) Gray finish DGYG

(standard)

Notes:1 Wired 277V.2 Wired 208V, 90L only3 90L only with 480V.

KP2

All dimensions are inches (millimeters) unlessotherwise noted.

Options

Roadway Lighting

KP290-180W LOW PRESSURE SODIUM

Sheet #: KP2-L RL-180

R4

6-3/4" (171)

L"

Accepts1-1/2" to 2" OD

Mounting

ARMS

7"(179)

10"(254)

KP2 Low Pressure Sodium Roadway Lighting

Lithonia LightingAcuity Lighting Group, Inc.Outdoor LightingOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209In Canada: 160 avenue Labrosse, Pointe-Claire, P.Q., H9R 1A1www.lithonia.com ©2004 Acuity Lighting Group, Inc. 04/05Sheet #: KP2-L

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

135W low pressure sodium lamp, rated 22500lumens. Footcandle values based on 20'mounting height.Classification: Type IV, Medium, Noncutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

2.51.5

1

0.5

0.25

TEST NO: LTL13218RKP2 135L R4 DLA

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

90W low pressure sodium lamp, rated 13500lumens. Footcandle values based on 20'mounting height.Classification: Type IV, Medium, Semicutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

2.5

1.51

0.5

0.25

TEST NO: LTL13219RKP2 90L R4 DLA

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Example: KRP 90L R4 DLA 120 PER LPI

FEATURES & SPECIFICATIONSINTENDED USE

Designed for maximum energy savings with efficient light distribution forgeneral roadway and area lighting. Ideal for coastal areas or anywherecorrosion is a concern.

CONSTRUCTION

Outer housing is constructed of non-corrosive ABS composite plastic withUV-inhibiting coating for long life in demanding environments.

ELECTRICAL

Standard ballast is high reactance (lag), high power factor. Reactor highpower factor ballast is available (90W only).

OPTICAL SYSTEMS

Drop prismatic acrylic refractor and adjustable socket allows for maximumcontrol of light distribution. Optional prismatic polycarbonate refractoravailable for increased vandal resistance. Large surface area “breathingseal” gasket seals the optical chamber to prevent intrusion by insects andenvironmental contaminants. Heat-resistant gasket material remainseffective over the life of the fixture.

INSTALLATION

Mast-arm mount provides easy, secure installation and adjustability forarms from 1-1/4” to 2” (32mm to 51mm) mast arms.

LISTING

Standard product is NOT listed by UL, CSA or NOM. For listing availability,consult factory. Complies with ANSI: C136.2, C136.10, C136.15

Series

KRP

Distribution

R4

Outdoor

Catalog Number

Notes Type

Standard dimensions(dimensions do not include mounting arm)

KRP EPA: 1.86ft2 (.17m2)Length: 65” (1651)Weight: 45 lbs. (20.4 kg)

Wattage/LampSource

90L135L180L

Lens

DLA Drop lensacrylic

Voltage

120208240277347480

208/2772

277/2081

Ballast Options

(blank) Standard ballast(see above)

RHP Reactor highpower factor3

Shipped Installed in FixtureLPI Lamp included as

standardL/LPPER NEMA twist-lock

receptacle only(photocontrol notincluded).

PEU NEMA twist-lock PESF Single 5-amp fuseDF Double 5-amp fuse

(blank) Gray finish DGYG(standard)

Notes:1 Wired 277V.2 Wired 208V, 90L only3 90L only with 480V.

KRP

All dimensions are inches (millimeters)unless otherwise noted.

Options

Roadway Lighting

KRP90-180W LOW PRESSURE SODIUM

Sheet #: KRP-L RL-190

DLA R4

6-3/4" (171)

L"

Accepts1-1/2" to 2" OD

Mounting

ARMS

7"(179)

10"(254)

KRP Low Pressure Sodium Roadway Lighting

Lithonia LightingAcuity Lighting Group, Inc.Outdoor LightingOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209In Canada: 160 avenue Labrosse, Pointe-Claire, P.Q., H9R 1A1www.lithonia.com ©2004 Acuity Lighting Group, Inc. 04/05Sheet #: KRP-L

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

135W low pressure sodium lamp, rated 22500lumens. Footcandle values based on 20'mounting height.Classification: Type IV, Medium, Semicutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.51.5

1

0.5

0.25

0.25

TEST NO: LTL13220RKRP 135L R4 DLA

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

90W low pressure sodium lamp, rated 13500lumens. Footcandle values based on 20'mounting height.Classification: Type IV, Medium, Semicutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

2.51.5

1

0.5

0.25

TEST NO: LTL13222RKRP 90L R4 DLA

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

180W low pressure sodium lamp, rated 33000lumens. Footcandle values based on 20'mounting height.Classification: Type IV, Medium, Noncutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.51.5

1

0.5

0.25

TEST NO: LTL13223R KRP 180L R4 DLA

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs and write it on theappropriate line. Order accessories as separate catalog number.

Example: KRX 90L R4 DLA 120 PER LPI

FEATURES & SPECIFICATIONSINTENDED USEDesigned for maximum energy savings with efficient light distribution forgeneral roadway and area lighting.CONSTRUCTIONUpper housing is rugged die-cast aluminum. Refractor is available inprismatic polycarbonate for increased vandal resistance.ELECTRICALStandard ballast is high reactance (lag), high power factor. Reactor highpower factor ballast is available (90W only).OPTICAL SYSTEMSDrop prismatic polycarbonate refractor available for increased vandalresistance. Large surface area “breathing seal” gasket seals the opticalchamber to prevent intrusion by insects and environmental contaminants.Heat-resistant gasket material remains effective over the life of the fixture.INSTALLATIONMast-arm mount provides easy, secure installation and adjustability forarms from 1-1/4” to 2” (32mm to 51mm) mast arms.LISTINGStandard product is NOT listed by UL, CSA or NOM. For listing availability,consult factory. Complies with ANSI: C136.2, C136.10, C136.15

Series

KRX

Distribution

R4

Outdoor

Catalog Number

Notes Type

Standard dimensions

(dimensions do not include mounting arm)

KRX EPA: .74 ft2 (.07m2)Weight: 20 lbs. (9.0 kg)

Wattage/Lamp Source

35L55L90L

Lens

DLP Drop lenspolycarbonate

Voltage

120208240277347480

120/2401

240/1204

208/2772

277/2085

Ballast Options

(blank) Standard ballast(see above)

RHP Reactor highpower factor3

Options

Shipped Installed in Fixture(blank) Natural aluminum

(standard)LPI Lamp included as

standardL/LP Less lampPER NEMA twist-lock

receptacle only(photocontrol notincluded).

PEU NEMA twist-lock PESF Single 5-amp fuseDF Double 5-amp fuse

NOTES:1 Wired 120V.2 Wired 208V, 90L only3 90L only with 480V.4 Wired 240V5 Wired 277V

KRX

All dimensions are inches unless otherwise noted.

Roadway Lighting

KRX

90-180W LOW PRESSURE SODIUM

Sheet #: KRX-L RL-200

R4

Mounting end of tenonmust have a 4-1/2"

straight section (min.)

Accepts1-5/8" to 2-3/8"

OD tenon

27"(686)

4-1/2"(114)

7-1/2"(191)

9"(229)

4"(102)

DLP

KRX Low Pressure Sodium Roadway Lighting

Lithonia LightingOutdoor LightingOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209www.lithonia.com ©2004 Acuity Lighting Group, Inc., Rev 04/06Sheet #: KRX-L

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

55W low pressure sodium lamp, rated 8000lumens. Footcandle values based on 20'mounting height.Classification: Type IV, Short, Noncutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

1.51

0.50.25

TEST NO: LTL13221RKRX 55L R3 DLA

Options

All dimensions are inches(centimeters) unlessotherwise specified.

Arm-Mounted Rectilinear Cutoff Lighting

KT1LOW PRESSURE SODIUM

90W20' to 30' Mounting

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Series

KT1 90LKT1 2/90L

Arm Length

D

Voltage

120

2081

2401

277

347

4801,2

Mounting7

SP04 Square poleRPO4 Round pole

WWO4 Wood pole or wallWB04 Wall bracket

Optional Pole Mounting(shipped separately)

DA12P Degree arm (pole)DA12WB Degree arm (wall)

SP063 Square poleRP063 Round pole

WW063 Wood pole or wallWB06 Wall bracket

KMA Mast arm adapterKTMB Twin mounting bar

Accessories: Tenon Mounting Slipfitter4

Number of fixtures

Tenon O.D. One Two@180° Three@120°2-3/8" (6) T20-190 T20-280 T20-3202-7/8" (7.3) T25-190 T25-280 T25-3204" (10.2) T35-190 T35-280 T35-320

Standard DimensionsEPA: 2.3 ft2 (.21m2)(includes arm)Length: 29-3/4 (75.6)Width: 15-3/4 (40.0)Depth: 8-1/4 (21.0)Arm length: 4 (10.1)Weight: 42 lbs (19 kg)

Mounting Option Drilling Template

SPxx, RPxx 5WBxx 6WWxx 7

Architectural colors (powderfinish)6

Standard colorsDDB Dark bronze (standard)

DWH WhiteDBL Black

Classic colorsDMB Medium bronzeDNA Natural aluminumDSS SandstoneDGC Charcoal grayDTG Tennis greenDBR Bright redDSB Steel blue

Shipped installed in fixtureSF Single fuse (120, 277, 347V)DF Double fuse (208, 240, 480V)

PER NEMA twist-lockreceptacle only (nophotocontrol)

CR Corrosion resistant finishEC Emergency circuit

CSA Listed and labeled tocomply with CanadianStandards.

Shipped separately5

PE1 NEMA twist-lock PE (120, 208,240V)

PE3 NEMA twist-lock PE (347V)PE4 NEMA twist-lock PE (480V)PE7 NEMA twist-lock PE (277V)

SC Shorting cap for PER option

Example: KT1 2/90L 120 SP04 SF DDB

NOTES:1 Consult factory for availability in Canada.2 Reactor ballast.3 The SP06, RP06 or WW06 must be used when two or

more luminaries are orientated on a 90° drillingpattern.

4 Order as separate line item. An RP04 mounting armmust be ordered on the fixture.

5 May be ordered as accessory.6 Other architectural colors available;

please see paint brochure.7 For arm mounting, refer to technical data section in

the Monarch binder for drilling template.

OUTDOOR

Catalog Number

Notes Type

Sheet#: KT1-L AL-410

FEATURES & SPECIFICATIONSINTENDED USEIdeal for parking lots, walkways and entrances.CONSTRUCTIONRugged, heavy-gauge, lightweight aluminum housing. Rectilinear shape,continuously seam-welded for weather-tight integrity.Naturally anodized, extruded, aluminum doorframe with mitered cor-ners is retained with (two) .188" diameter hinge pins and secured with(one) quarter-turn, quick release fastener.Weather-proof seal between housing and door frame is accomplishedwith an integrally designed, extruded, silicone gasket that snaps intodoor frame.Lens is .125" thick, impact-resistant, tempered glass with thermally-ap-plied, silk screened power door shield.FINISHStandard finish is dark bronze (DDB), polyester powder with optionalarchitectural colors available.OPTICAL SYSTEMHigh reflectance, white reflector, IES cutoff distribution.ELECTRICAL SYSTEMHigh reactance autotransformer is copper wound and 100% factorytested. Double contact bayonet socket.INSTALLATIONExtruded, 4" aluminum arm for pole or wall mounting.LISTINGUL 1572 listed for wet locations. Listed and labeled to comply with Cana-dian Standards (see Options).

Coefficient of UtilizationInitial Footcandles

KT1 Arm-Mounted Rectilinear Cutoff Lighting

Mounting Height Correction Factor(Multiply the fc level by the correction factor)15 ft.= 2.7818 ft.= 1.9320 ft.= 1.5630 ft.= 0.69

52.5

1.5

.25

KT1 Test No. 1190022803

COEFFICIENT OF UTILIZATION

.0 .1 .2 .3 .4 .5 .6

DIS

TAN

CE

INU

NIT

SO

FM

OU

NT

ING

HE

IGH

T

0 1 2 3 4 5 6

2

1

0

1

2

3

4

2/90LW Low Pressure Sodium lamp, 13500 ratedlumens. Footcandle values based on 25'mounting height, Distribution , cutoff.

NOTES:1. For electrical characteristics, consult technical data tab.2 Tested to current IES and NEMA standards under stabilized

laboratory conditions. Various operating factors can causedifferences between laboratory and actual field measurements. Dimensions and specifications are based on themost current available data and are subject to change.

KT1-L ©2001 Lithonia Lighting, Rev. 04/06

Lithonia LightingOutdoor LightingOne Lithonia Way, Conyers, GA 30012-3957Phone: 770-922-9000 Fax: 770-918-1209www.lithonia.com

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Example: TDR 200S R3 SLG 120 PER LPI

FEATURES & SPECIFICATIONSINTENDED USE

Unique optical design allows set-back of mounting poles away from traficareas while still delivering exceptional spacing to mounting-heightperformance.

CONSTRUCTION

Rugged die-cast aluminum housing and doorframe provide strength andcorrosion resistance. Single-latch too-less access doorframe available.Large surface-area “breathing seal” polyester gasketing protects reflectorand lens from contaminants, maintaining maximum optical efficiency.Munsell grey polysester powder paint finish is electrostatically applied forsuperior corrosion resistance. Available with or without twist-lockphotocontrol receptacle.

ELECTRICAL

Constant wattage autotransformer ballasts are standard (other ballastsavailable). All electrical systems are 100% factory tested. Three position (L1, L2,N) tunnel-type compression terminal block for supply connection is standard.

OPTICAL SYSTEMS

Reflectors are high-efficiency hydroformed anodized aluminum deliveringprecise roadway type lll distribution. Lens is available in flat tempered glassor sag glass for maximum spacings. Mogul-based screw shell socket isnickel plated brass and has center-spring contact.

INSTALLATION

Standard product mounts to 2-3/8” tenon and offers adjustable aimingangle. Yoke-mount allowing 360o rotation available.

LISTING

UL listed. CSA listing available

Series

TDR

Distribution

R3

Outdoor

Standard dimensions(dimensions do not include mounting arm)

TDR EPA: .74 ft2 (.07m2)Weight: 37 lbs. (16.8 kg)

Lens

FL Flat temperedglass lens, fullcutoff

SLG Sag lens glass

Voltage

120208240277347480TB1

TB11

TB21

TB31

Ballast Options

(blank) Constant wattageautotransformer

RNP Reactor normal powerfactor2

RHP Reactor high powerfactor2

XNP High reactance(lag)normal pwerfactor2

XHP High rectance (lag)high power factor2

50HZ 50 hertz. Consultfactory.

MRB Mag Reg ballastCWI CWI ballast

NOTE: SCWA option must be selectedto comply with California Title 20regulations. SCWA also may berequired to meet other states'regulations. Consult local authoritIes.SCWA SCWA pulse-start

Shipped Installed in FixtureLPI Lamp included as

standardLPIC Coated lamp

includedL/LP Less lampPER NEMA twist-lock

receptacle only(photocontrol notincluded).

PEU NEMA twist-lock PEOPS Open plug-in starterENP Encapsulated plug-

in starterDPL Distribution pattern

labelT2P Terminal block-two

position wired L1 L2T3P Terminal block-

three position wiredL1, N, L2

HSS Stainless steelexternal hardwareNOTES:

1 Optional multi-tap ballast (120, 208, 240, 277V). TBprewired to 277V. Others are: 1=120V; 2=208V; 3=240V.

2 HPS only.3 Available in 208, 240, 480V only.

TDR

All dimensions are inches unless otherwise noted.

LSA1 Single lightningsurge arrestor

LSA2 Dual lightning surgearrestor3

SF Single 5-amp fuseDF Double 5-amp fuse

(blank) Gray finish(standard)

DDB Dark bronze finishDBL Black finish

DWH White finishShipped Separately

SC Shorting cap forPER option

Options

Roadway Lighting – Offset Direct

TDR200-400W HIGH PRESSURE SODIUM

250-400W METAL HALIDE

Sheet #: TDR-M-S RL-210

R3

3 ”

7 ” 17.75”

21.1”

19.5”

Catalog Number

Notes Type

Wattage/LampSource

High pressuresodium

200S250S310S

250/400S400S

400/250SMetal halide

250M320M400M

TDR High Pressure Sodium, Metal Halide Roadway Lighting

Sheet #: TDR-M-S

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

400W high pressure sodium lamp, rated 50000lumens. Footcandle values based on 20'mounting height.Classification: Type III, Medium, Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.51.5

1

0.5

0.25

TEST NO: LTL13167RTDR 400S R3 SLG

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

400W metal halide lamp, rated 34000lumens. Footcandle values based on 20'mounting height.Classification: Type III, Short, Full Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

52.51.5

1

0.5

0.25

TEST NO: LTL13168RTDR 400M R2 SLG

©2004 Acuity Brands Lighting, Inc., Rev. 8/14/08

Lithonia LightingOutdoorOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209www.lithonia.com

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Example: TDS2 150S R2 SLG 120 PER LPI

FEATURES & SPECIFICATIONSINTENDED USERoadways where high-performance lighting is required along with ease ofmaintenance. Also ideal for roadways and area lighting in coastal areas oranywhere corrosion is a concern.CONSTRUCTIONComposite fixture housing resists impact, is non conductive, and resistsweather and corrosive environments. High temperature UV stabilizedmaterial ensures long-term reliability under harsh sunlight and humidity.ELECTRICALStandard ballast varies by wattage and source and can be specified.Reactor (normal and high power factor), high reactance lag (normal andhigh power factor), constant wattage transformer, isolated coil, and pulse-start ballasts are available (consult factory). Three-position (L1, L2, N)tunnel-type compression terminal block for supply connection is standard.OPTICAL SYSTEMSHigh-reflectance metalized reflectors deliver optimum lighting performanceand efficiency. Large surface area “breathing seal” gasket seals theoptical chamber to prevent intrusion by insects and environmentalcontaminants. Heat-resistant gasket material remains effective over the lifeof the fixture.INSTALLATIONDocking system provides modular installation and interchangeability foreasy maintenance. Rugged die-cast, powder-coated docking stationmounts securely to mast-arm to ensure secure wiring and long lastingstability. Durable lightweight lighting fixture positively docks by plugging inwith a 20o locking twist. Die-cast trigger latch on door frame enables easyand secure one-hand opening for re-lamping and maintenance.LISTINGStandard product is NOT listed by UL, CSA or NOM. For listing availability,consult factory. Complies with ANSI: C136.2, C136.10, C136.15.

Series

TDS2

Distribution

R2R3

Outdoor

Standard dimensions(dimensions do not include mounting arm)

Flat Lens EPA: .56 ft2 (.05m2)Drop Lens EPA: .70 ft2 (.07 m2)

Flat Lens Length: 26 1/2” (673)Flat Lens Width: 12 1/2” (318)Flat Lens Depth: 9” (228)

Weight: 14 lbs. (6.4 kg)

Wattage/lamp source

High pressure sodium35S50S70S100S150S

Metal halide70M

100M175M

Lens

SLA Sag lens acrylicSLP Sag lens

polycarbonateSLG Sag lens glass

FL Flat temperedglass lens, fullcutoff

Voltage

120208240277347480TB1

TB11

TB21

TB31

NOTES:1 Optional multi-tap ballast (120, 208, 240, 277V). TB

prewired to 277V. Others are: 1=120V; 2=208V; 3=240V.2 HPS only3 120,277 only. N/A with TB.

TDS2

All dimensions are inches (millimeters) unless otherwise noted.

Roadway Lighting

TDS235-150W HIGH PRESSURE SODIUM

70-175W METAL HALIDE

Sheet #: TDS2-M-S RL-220

9.2"(234)

26.5"(673)

12.5"(318)

Catalog Number

Notes Type

Ballast

RNP Reactor normal powerfactor2

RHP Reactor high powerfactor2

XNP High reactance(lag)normal pwerfactor2

XHP High rectance (lag)high power factor2

50HZ 50 hertz. Consultfactory.

MRB Mag Reg ballastCWI CWI ballast

CWA Constant wattageauto-transformer

NOTE: SCWA ballast must be selectedto comply with California Title 20metal halide regulations. SCWA alsomay be required to meet other states'regulations. Consult local authoritIes.SCWA SCWA pulse-start

Options

Shipped Installed in FixtureLPI Lamp included as standard

LPIC Coated lamp includedL/LP Less lampPER NEMA twist-lock receptacle only

(photocontrol not included).PEU NEMA twist-lock PEMA2 2-bolt internal 2” pipe settingOPS Open plug-in starterENP Encapsulated plug-in starter

UL UL listedCSA CSA listedHSS Stainless steel external

hardwareLSA Single lightning surge arrestor

SF Single 5-amp fuseDF Double 5-amp fuse3

(blank) Gray finish (standard)Shipped Separately

SC Shorting cap for PER option

TDS2 High Pressure Sodium and Metal Halide Roadway Lighting

Sheet #: TDS2-M-S

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

150W high pressure sodium lamp, rated 16000lumens. Footcandle values based on 20'mounting height.Classification: Type II, Medium, Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.51.5

10.5

0.25

TEST NO: LTL13195RTDS2 150S R2 SLP

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

150W high pressure sodium lamp, rated 16000lumens. Footcandle values based on 20'mounting height.Classification: Type II, Medium, Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.51.5

10.5

0.25

TEST NO: LTL13196RTDS2 150S R2 FL

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

150W high pressure sodium lamp, rated 16000lumens. Footcandle values based on 20'mounting height.Classification: Type III, Medium, Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.51.5

10.5

0.25

TEST NO: LTL13199RTDS2 150S R3 FL

©2004 Acuity Brands Lighting, Inc., Rev. 2/29/08

Lithonia LightingOutdoorOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209www.lithonia.com

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Example: TDS3 200S R2 SLG 120 PER LPI

FEATURES & SPECIFICATIONSINTENDED USE

Roadways where high-performance lighting is required along with ease ofmaintenance. also ideal for roadways and area lighting in coastal areas oranywhere corrosion is a concern.

CONSTRUCTION

Composite fixture housing resists impact, is non conductive, and resistsweather and corrosive environments. High temperature UV stabilizedmaterial ensures long-term reliability under harsh sunlight, heat andhumidity.

ELECTRICAL

Constant wattage autotransformer ballasts are standard (other ballastsavailable). All electrical systems are 100% factory tested. Three-position (L1,L2, N) tunnel-type compression terminal block for supply connectionstandard.

OPTICAL SYSTEMS

High-reflectance metalized reflectors deliver optimum lighting performanceand efficiency. Large surface area “breathing seal” gasket seals theoptical chamber to prevent intrusion by insects and environmentalcontaminants. Heat-resistant gasket material remains effective over the lifeof the fixture.

INSTALLATION

Docking system provides modular installation and interchangeability foreasy maintenance. Rugged die-cast, powder-coated docking stationmounts securely to mast-arm to ensure secure wiring and long lastingstability. Durable lightweight lighting fixture positively docks by plugging inwith a 20o locking twist. Die-cast trigger latch on door frame enables easyand secure one-hand opening for re-lamping and maintenance.

LISTING

Standard product is NOT listed by UL, CSA or NOM. For listing availability,consult factory. Complies with ANSI: C136.2, C136.10, C136.15.

Series

TDS3

Distribution

R2R3

Outdoor

Catalog Number

Notes Type

Standard dimensions(dimensions do not include mounting arm)

Flat Lens EPA: 1.24 ft2 (.12m2)Drop Lens EPA: 1.43 ft2 (.13 m2)

Flat Lens Length: 36 1/4” (921)Flat Lens Width: 17 1/2” (445)Flat Lens Depth: 10” (254)

Weight: 35 lbs. (15.9 kg)

Wattage/lampsource

High pressuresodium

200S250S310S

250/400S400S

400/250SMetal halide

250M320M400M

250/400M400/250M

Lens

FL Flattemperedglass lens,full cutoff

SLG Sag lensglass

Voltage

120208240277347480TB1

TB11

TB21

TB31

Ballast

(blank) Constant wattageautotransformer

RNP Reactor normalpower factor2

RHP Reactor highpower factor2

XNP High reactance(lag) normalpower factor2

XHP High reactance(lag) high powerfactor2

50HZ 50 hertz. Consultfactory.

MRB Mag Reg ballastCWI CWI ballast

NOT E: SCWA ballas t must beselected to comply wi thCal ifornia Ti t le 20 metalhal ide regulat ions . S CWAalso may be required to meetother s t a tes' regulat ions .Consul t local author i t ies .SCWA SCWA pulse-start

NOTES:1 Optional multi-tap ballast (120, 208, 240, 277V). TB prewired to 277V. Others are: 1=120V;

2=208V; 3=240V.2 HPS only.3 Available in 208, 240, 480V only.

TDS3

All dimensions are inches (millimeters) unlessotherwise noted.

Options

Shipped Installed in FixtureLPI Lamp included as standard

LPIC Coated lamp includedL/LP Less lampPER NEMA twist-lock receptacle

only (photocontrol notincluded).

PEU NEMA twist-lock PEMA2 2-bolt internal 2” pipe settingOPS Open plug-in starter3

ENP Encapsulated plug-in starterHSS Stainless steel external

hardwareLSA Single lightning surge

arrestorSF Single 5-amp fuseDF Double 5-amp fuse3

DBL Black finishDWH White finish

DGYG Gray finishShipped Separately

SC Shorting cap for PER option

Roadway Lighting

TDS3200-400W HIGH PRESSURE SODIUM

250-400W METAL HALIDE

Sheet #: TDS3-M-S RL-230

36 - 1/4 (921)

17-1/2"(445)

11"(279)

TDS3 High Pressure Sodium and Metal Halide Roadway Lighting

Lithonia LightingOutdoor LightingOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209www.lithonia.com ©2004 Acuity Brands Lighting, Inc. 8/14/08Sheet #: TDS3-M-S

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

250W high pressure sodium lamp, rated 27500lumens. Footcandle values based on 20'mounting height.Classification: Type II, Medium, Full Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.5

1.5

1

0.5

0.25

0.25

TEST NO: LTL13208RTDS3 250S R2 FL

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

250W high pressure sodium lamp, rated 27500lumens. Footcandle values based on 20'mounting height.Classification: Type III, Medium, Full Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.5

1.5

1

0.5

0.25

0.25

TEST NO: LTL13209RTDS3 250S R3 FL

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

400W high pressure sodium lamp, rated 50000lumens. Footcandle values based on 20'mounting height.Classification: Type III, Medium, Full Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.5

1.51

0.5

0.5

0.25

TEST NO: LTL13210RTDS3 400S R3 FL

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

400W metal halide lamp, rated 34000lumens. Footcandle values based on 30'mounting height.Classification: Type II, Medium, Full Cutoff

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.51.5

1

0.5

0.25

TEST NO: LTL13212RTDS3 400M R2 FL

_

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Example: TDX 150S R2 SLG 120 PER LPI

FEATURES & SPECIFICATIONSINTENDED USE

Residential and commercial roadways where economical solutions arerequired.

CONSTRUCTION

Die-cast aluminum ballast chamber for cool operation. Anodized aluminumoptical chamber resists corrosion.

ELECTRICAL

Standard ballast is constant wattage autotransformer (optional high powerfactor available). Three-position (L1, L2, N) tunnel-type compressionterminal block for suply connection is standard.

OPTICAL SYSTEMS

High efficiency anodized aluminum reflector delivers effective roadwaydistribution with sag acrylic lens.

INSTALLATION

Mounts to standard 1-3/4” pipe or david arm.

LISTING

Standard product is NOT listed by UL, CSA or NOM. For listing availability,consult factory. Complies with ANSI: C136.2, C136.10, C136.15.

Series

TDX

Distribution

R1R2R5

Outdoor

Catalog Number

Notes Type

Standard dimensions(dimensions do not include mounting arm)

TDX EPA: .74 ft2 (.07m2)Weight: 12 lbs. (5.4 kg)

Wattage/LampSource

35S50S70S

100S150S

Lens

FL Flat temperedglass lens, fullcutoff1

SLG Sag lens glass

Voltage

120

Ballast Options

(blank) Constant wattageautotransformer

RHP Reactor highpower factor

50HZ 50 hertz. Consultfactory.

Shipped Installed in Fixture

LPI Lamp included asstandard

LPIC Coated lamp includedPER NEMA twist-lock

receptacle only(photocontrol notincluded).

PEU NEMA twist-lock PEHSS Stainless steel external

hardware

TDX

All dimensions are inches unless otherwisenoted.

Options

Roadway/Security Lighting

TDX35-150W HIGH PRESSURE SODIUM

Sheet #: TDX-S RL-240

23-1/16"(585 mm)

7-27/32"(199 mm)

12-3/32"(307 mm)

TDX High Pressure Sodium Roadway/Security Lighting

Lithonia LightingAcuity Lighting Group, Inc.Outdoor LightingOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209In Canada: 160 avenue Labrosse, Pointe-Claire, P.Q. H9R 1A1www.lithonia.com ©2004 Acuity Lighting Group, Inc.8/14/08Sheet #: TDX-S

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Example: TMM 200S R3 DLA 120 PER LPI

FEATURES & SPECIFICATIONSINTENDED USE

Unique optical design allows set-back of mounting poles away from trafficareas while still delivering exceptional spacing to mounting-height andarchitectural aesthetics.

CONSTRUCTION

Rugged die-cast aluminum housing and doorframe provide strength andcorrosion resistance. Standard doorframe can be easily opened with onehand without tools via dies-cast latch. Large surface area “breathing-seal”polyester gasketing protects reflector and lens from contaminants,maintaining maximum optical efficiency. Dark bronze polyester powderpaint finish is electrostatically applied for superior corrosion resistance.Available with or without twist-lock photocontrol receptacle.

ELECTRICAL

Constant wattage autotransformer ballasts are standard (other ballastsavailable). All electrical systems are 100% factory tested. Three-position (L1,L2, N) tunnel type compression terminal block standard.

OPTICAL SYSTEMS

Reflectors are high-efficiency hydroformed anodized aluminum deliveringprecise roadway type III distribution. Refractor is prismatic acrylic. Mogul-based screw shell socket is nickel plated brass and has center-springcontact.

INSTALLATION

Standard product mounts to 2-3/8” tenon and offers adjustable aiming angle.

LISTING

UL listed. (Consult factory for CSA)

Series

TMM

Distribution

R3

Outdoor

Standard dimensions

(dimensions do not include mounting arm)

TMM EPA: 2.1 ft2 (.20m2)Weight: 42 lbs. (19.1 kg)

Wattage/lampsource

High pressuresodium

200S250S310S

250/400S400S

400/200SMetal halide

250M320M400M

Lens

DLA Drop lens acrylic

Voltage

120208240277480TB1

TB11

TB21

TB31

Options

Shipped Installed in FixtureLPI Lamp included as standard

LPIC Coated lamp includedL/LP Less lampPER NEMA twist-lock receptacle

only (photocontrol notincluded).

PEU NEMA twist-lock PEOPS Open plug-in starterENP Encapsulated plug-in starterT2P Terminal block-two position

wired L1 L2T3P Terminal block-three position

wired L1, N, L2HSS Stainless steel external

hardwareLSA Single lightning surge

arrestorSF Single 5-amp fuseDF Double 5-amp fuse3

(blank) Dark bronze finish (standard)DBL Black finish

DWH White finishDGYG Gray finishNOTES:

1 Optional multi-tap ballast (120, 208, 240, 277V). TBprewired to 277V. Others are: 1=120V; 2=208V; 3=240V.

2 HPS only.3 Available in 208, 240, 480V only.

TMM

All dimensions are inches unless otherwise noted.

Roadway Lighting-Offset

TMM200-400W HIGH PRESSURE SODIUM

250-400W METAL HALIDE

Sheet #: TMM-M-S RL-250

R3

17"(432)

27-1/4"(692)

11-1/4"(286)

5-1/4"(133)

3"(76)

Catalog Number

Notes Type

Ballast

RNP Reactor normal power factor2

RHP Reactor high power factor2

XNP High reactance (lag)normalpwer factor2

XHP High rectance (lag) highpower factor2

50HZ 50 hertz. Consult factory.MRB Mag Reg ballastCWI CWI ballast

CWA Constant wattage auto-transformer

NOTE: SCWA ballast must be selected tocomply with California Title 20 metal halideregulations. SCWA also may be required tomeet other states' regulations. Consult localauthorities.SCWA SCWA pulse-start

TMM High Pressure Sodium and Metal Halide Roadway Lighting

Sheet #: TMM-M-S ©2004 Acuity Brands Lighting, Inc., Rev. 2/29/08

Lithonia LightingOutdoorOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209www.lithonia.com

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Example: TSL 200S RM FL 120 LPI

FEATURES & SPECIFICATIONSINTENDED USE

Interstate highway signage, outdoor advertising, trafic flow signs, buildingfacades.

CONSTRUCTION

Die-cast low copper content aluminum housing offers superior durabilityand corrosion resistance. Hinged door easily removable for quickmaintenance. Single fastener makes re-lamping easy (optional tool-lessentry is available).

ELECTRICAL

Standard ballast varies by wattage and source and can be specified. 250Wand above standard Constant wattage Autotransformer. Reactor (normaland high power factor), high reactance lag (normal and high power factor),isolated coil, magnetic regulator, and pulse-start ballasts are available(consult factory).

OPTICAL SYSTEMS

Anodized aluminum reflector provides uniform lighting distribution withchoice of flat tempered glass or sag tempered glass lens.

INSTALLATION

Standard product mounts to 2-3/8” tenon. Other mounting options areavailable (consult factory).

LISTING

Standard product is listed by UL for wet locations. Complies with ANSI:C136.2, C136.10, C136.15

Series

TSL

Distribution

RM (5Hx6V)RB (6Hx6V)

Outdoor

Catalog Number

Notes Type

Standard dimensions(dimensions do not include mounting arm)

TSL Lens EPA: 1.75 ft2 (.16m2)Weight: 37 lbs. (16.8 kg)

Wattage/lampsource

High pressuresodium

70S100S150S200S250S400S

Metal halide70M175M250M400M

Lens

FL Flattemperedglass lens,full cutoff

SLG Sag lensglass

Voltage

120208240277347480TB1

TB11

TB21

TB31

Ballast

(blank) Standard ballast(see above)

RNP Reactor normalpower factor

RHP Reactor highpower factor

XNP High reactance(lag) normal powerfactor

XHP High reactance(lag) high powerfactor

MRB Mag Reg ballastCWI CWI ballast

CWA Constant wattageauto-transformer

NOTE: SCWA ballast must beselected to comply with CaliforniaTitle 20 metal halide regulations.SCWA also may be required to meetother states' regulations. Consultlocal authorities.

SCWA SCWA pulse-start

NOTES:1 Quad-tap ballast (120/208/240/277V wired to 277V.

Factory wiring to other voltages is available.2 120&277V.3 208, 240, 480V.

TSL

All dimensions are inches (millimeters) unlessotherwise noted.

Options

Shipped Installed in FixtureLPI Lamp included

L/LP Less lampPER NEMA twist-lock receptacle only

(photocontrol not included).PEU NEMA twist-lock PEOPS Open plug-in starterENP Encapsulated plug-in starterENX External encapsulated plug-in

starterT2P Terminal block-two position wired

L1 L2T3P Terminal block-three position wired

L1, N, L2HSS Stainless steel external hardwareLSA Single lightning surge arrestor2

SF Single 5-amp fuse2

DF Double 5-amp fuse3

CSA CSA listed(blank) Gray finish (standard)

DDB Dark bronze finishDBL Black finish

DWH White finish

Sign Lighting

TSL70-400W HIGH PRESSURE SODIUM

70-400W METAL HALIDE

Sheet #: TSL-M-S RL-260

TSL High Pressure Sodium and Metal Halide and Sign Lighting

Lithonia LightingOutdoor LightingOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209www.lithonia.com ©2004 Acuity Brands Lighting, Inc. 02/29/08Sheet #: TSL-M-S

Nema Type:Maximum Candlepower:Horizontal Beam Angle (50%):Vertical Beam Angle (50%):Horizontal Field Angle (10%):Vertical Field Angle (10%):Beam Lumens:Beam Efficiency:Field Lumens:Field Efficiency:Total Efficiency:

5 H x 6 V16591 at 12˚ H, 0˚ V69.116.298.0107.7370526.5882263.073.6

Cartesian Plot

Angle (Deg)

-90˚ -60˚ -30˚ 0˚ 30˚ 60˚ 90˚0

4200

8400

12600

16800

21000

25200

29400

33600

37800

42000

VerticalVerticalVerticalVerticalVerticalVerticalVerticalVerticalVerticalHorizontal

Inte

nsity

Nema Type:Maximum Candlepower:Horizontal Beam Angle (50%):Vertical Beam Angle (50%):Horizontal Field Angle (10%):Vertical Field Angle (10%):Beam Lumens:Beam Efficiency:Field Lumens:Field Efficiency:Total Efficiency:

7 H x 6 V26015 at 25˚ H, 0˚ V109.246.7131.8126.72237744.83812276.279.5

Cartesian Plot

Angle (Deg)

-90˚ -60˚ -30˚ 0˚ 30˚ 60˚ 90˚0

4200

8400

12600

16800

21000

25200

29400

33600

37800

42000

VerticalVerticalVerticalVerticalVerticalVerticalVerticalVerticalVerticalHorizontal

Inte

nsity

Nema Type:Maximum Candlepower:Horizontal Beam Angle (50%):Vertical Beam Angle (50%):Horizontal Field Angle (10%):Vertical Field Angle (10%):Beam Lumens:Beam Efficiency:Field Lumens:Field Efficiency:Total Efficiency:

6 H x 6 V25366 at 25˚ H, 0˚ V100.225.4126.7120.2912226.82573375.779.1

Cartesian Plot

Angle (Deg)

-90˚ -60˚ -30˚ 0˚ 30˚ 60˚ 90˚0

4200

8400

12600

16800

21000

25200

29400

33600

37800

42000

VerticalVerticalVerticalVerticalVerticalVerticalVerticalVerticalVerticalHorizontal

Inte

nsity

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Example: TSL 200S RM FL 120 LPI

FEATURES & SPECIFICATIONSINTENDED USE

Interstate highway signage, outdoor advertising, trafic flow signs, buildingfacades.

CONSTRUCTION

Die-cast low copper content aluminum housing offers superior durabilityand corrosion resistance. Hinged door easily removable for quickmaintenance. Single fastener makes re-lamping easy (optional tool-lessentry is available).

ELECTRICAL

Standard ballast is constant wattage autotransformer. Reactor (normal andhigh power factor), high reactance lag (normal and high power factor),isolated coil, magnetic regulator, and pulse-start ballasts are available(consult factory).

OPTICAL SYSTEMS

Anodized aluminum reflector provides uniform lighting distribution withchoice of flat tempered glass or sag tempered glass lens.

INSTALLATION

Standard product mounts to 2-3/8” tenon. Other mounting options areavailable (consult factory).

LISTING

Standard product is listed by UL for wet locations. Complies with ANSI:C136.2, C136.10, C136.15

Series

TSL

Distribution

RM (5Hx6V)RB (6Hx6V)

Outdoor

Catalog Number

Notes Type

Standard dimensions(dimensions do not include mounting arm)

TSL Lens EPA: 1.75 ft2 (.16m2)Weight: 37 lbs. (16.8 kg)

Wattage/lampsource

High pressuresodium

70S100S150S200S250S400S

Metal halide70M

175M250M400M

Lens

FL Flattemperedglass lens,full cutoff

SLG Sag lensglass

Voltage

120208240277347480TB1

TB11

TB21

TB31

Ballast

(blank) Constant wattageautotransformer

RNP Reactor normalpower factor

RHP Reactor highpower factor

XNP High reactance(lag) normalpower factor

XHP High reactance(lag) high powerfactor

MRB Mag Reg ballastCWI CWI ballast

NOTE: SCWA ballast must beselected to comply withCalifornia Title 20 metal halideregulations. SCWA also may berequired to meet other states'regulations. Consult localauthoritIes.SCWA SCWA pulse-start

Shipped Installed in FixtureLPI Lamp included

L/LP Less lampPER NEMA twist-lock receptacle

only (photocontrol not included).PEU NEMA twist-lock PEOPS Open plug-in starterENP Encapsulated plug-in starterENX External encapsulated plug-in

starterT2P Terminal block-two position

wired L1 L2T3P Terminal block-three position

wired L1, N, L2HSS Stainless steel external

hardwareLSA Single lightning surge arrestor2

SF Single 5-amp fuse2

DF Double 5-amp fuse3

CSA CSA listed(blank) Gray finish (standard)

DDB Dark bronze finishDBL Black finish

DWH White finish

Notes:1 Quad-tap ballast (120/208/240/277V) wired to 277V.

Factory wiring to other voltages is available.2 120&277V.3 208, 240, 480V.

TSL

All dimensions are inches (millimeters) unlessotherwise noted.

Options

Sign Lighting

TSL70-400W HIGH PRESSURE SODIUM

70-400W METAL HALIDE

Sheet #: TSL-M-S RL-260

TSL High Pressure Sodium and Metal Halide Sign Lighting

Lithonia LightingAcuity Lighting Group, Inc.Outdoor LightingOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209In Canada: 160 avenue Labrosse, Pointe-Claire, P.Q., H9R 1A1www.lithonia.com ©2004 Acuity Lighting Group, Inc. 08/14/08Sheet #: TSL-M-S

Nema Type:Maximum Candlepower:Horizontal Beam Angle (50%):Vertical Beam Angle (50%):Horizontal Field Angle (10%):Vertical Field Angle (10%):Beam Lumens:Beam Efficiency:Field Lumens:Field Efficiency:Total Efficiency:

5 H x 6 V16591 at 12˚ H, 0˚ V69.116.298.0107.7370526.5882263.073.6

Cartesian Plot

Angle (Deg)

-90˚ -60˚ -30˚ 0˚ 30˚ 60˚ 90˚0

4200

8400

12600

16800

21000

25200

29400

33600

37800

42000

VerticalVerticalVerticalVerticalVerticalVerticalVerticalVerticalVerticalHorizontal

Inte

nsity

Nema Type:Maximum Candlepower:Horizontal Beam Angle (50%):Vertical Beam Angle (50%):Horizontal Field Angle (10%):Vertical Field Angle (10%):Beam Lumens:Beam Efficiency:Field Lumens:Field Efficiency:Total Efficiency:

7 H x 6 V26015 at 25˚ H, 0˚ V109.246.7131.8126.72237744.83812276.279.5

Cartesian Plot

Angle (Deg)

-90˚ -60˚ -30˚ 0˚ 30˚ 60˚ 90˚0

4200

8400

12600

16800

21000

25200

29400

33600

37800

42000

VerticalVerticalVerticalVerticalVerticalVerticalVerticalVerticalVerticalHorizontal

Inte

nsity

Nema Type:Maximum Candlepower:Horizontal Beam Angle (50%):Vertical Beam Angle (50%):Horizontal Field Angle (10%):Vertical Field Angle (10%):Beam Lumens:Beam Efficiency:Field Lumens:Field Efficiency:Total Efficiency:

6 H x 6 V25366 at 25˚ H, 0˚ V100.225.4126.7120.2912226.82573375.779.1

Cartesian Plot

Angle (Deg)

-90˚ -60˚ -30˚ 0˚ 30˚ 60˚ 90˚0

4200

8400

12600

16800

21000

25200

29400

33600

37800

42000

VerticalVerticalVerticalVerticalVerticalVerticalVerticalVerticalVerticalHorizontal

Inte

nsity

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Example: TW5 200S 120 PE LPI

FEATURES & SPECIFICATIONSINTENDED USE

Low profile design and efficient light distribution is ideal for underpass andtunnel lighting.

CONSTRUCTION

Backplate and front housing are rugged die-cast aluminum polyesterpowder coated for corrosion resistance. Lens is thermal-shock resistantborosilicate glass.

ELECTRICAL

Standard ballast varies by wattage and source and can be specified.Reactor (normal and high power factor), high reactance lag (normal andhigh power factor), isolated coil, magnetic regulator, and pulse-startballasts are available (consult factory).

OPTICAL SYSTEMS

Prismatic borosilicate glass refractor and internal reflector optimizeefficiency and light distribution.

INSTALLATION

Mount on any flat, non-combustible surface. Rear wiring entry for mountingover standard j-box. Multiple surface conduit entry hubs also provided.

LISTING

UL listed for wet locations (standard).

Series

TW5

Outdoor

Catalog Number

Notes Type

Wattage/lamp source

High pressure sodium70S

100S150S200S250S

Metal halide175M250M

Voltage

120208240277347480TB1

TB11

TB21

TB31

Ballast

(blank) Standard ballast (see above)RNP Reactor normal power factorRHP Reactor high power factorXNP High reactance (lag) normal

power factorXHP High reactance (lag) high

power factorCWI CWI ballast

CWA Constant wattage auto-transformer

NOTE: SCWA ballast must be selectedto comply with California Title 20 metalhalide regulations. SCWA also may berequired to meet other states'regulations. Consult local authorities.SCWA SCWA pulse-start

NOTES:1 Quad-tap ballast (120/208/240/277V. TB prewired to 277V.

Others over 1=120V, 2=208V, 3=240V2 Not available with 480V.3 Not available with multi-tap ballast.

TW5

Options

Shipped installed in fixtureLPI Lamp included as standard

L/LP Less lampPE Photoelectric cell, button type2,3

HSS Stainless steel external hardwareSF Single 5-amp fuseDF Double 5-amp fuse

WG WireguardVG Vandal guard

Architectural colors(blank) Dark bronze finish (standard)

DBL Black finishDWH White finish

DGYG Gray finish

Roadway LightingWall -Mounted Underpass and Tunnel

TW570-250W HIGH PRESSURE SODIUM

70-250W METAL HALIDE

Sheet #: TW5-M-S RL-270

14-7/8"(378)

14-7/8"(378)

7" (179)

16-5/8"(424)

8-9/16"(251)

TW5 High Pressure Sodium and Metal Halide Roadway Lighting

Lithonia LightingOutdoor LightingOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209www.lithonia.com ©2004 Acuity Brands Lighting, Inc. 2/29/08Sheet #: TW5-M-S

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

150W high pressure sodium lamp, horizontal lamp orientation

Footcandle values based on 12'

mounting height, 16000 rated lumens.

-2

-1

0

1

2

3

40 1 2 3 4 5

5

2.5

1.5

1

0.5

0.25

TEST NO: LTL13192RTW5 150S

Luminaire Efficiency: 74.1%

DIS

TA

NC

EIN

UN

ITS

OF

MO

UN

TIN

GH

EIG

HT

ISOILLUMINANCE PLOT (Footcandle)

175W mercury vapor lamp, horizontal lamp orientationFootcandle values based on 12'

mounting height, 14000 rated lumens.

-2

-1

0

1

2

3

40 1 2 3 4 5

5 2.5

1.5 1

0.5

0.25

TEST NO: LTL13193RTW5 175MV

Luminaire Efficiency: 95.9%

ORDERING INFORMATIONChoose the boldface catalog nomenclature that best suits your needs andwrite it on the appropriate line. Order accessories as separate catalog number.

Example: TW6 200S 120 PE LPI

FEATURES & SPECIFICATIONSINTENDED USE

Low profile design and efficient light distribution is ideal for underpass andtunnel lighting. Ideal for areas requiring increased vandal resistance.

CONSTRUCTION

Back housing is rugged die-cast aluminum polyester powder coated forcorrosion resistance. Front housing is one-piece UV stabilized polycarbon-ate for vandal resistance.

ELECTRICAL

Standard ballast varies by wattage and source and can be specified.Reactor (normal and high power factor), high reactance lag (normal andhigh power factor), isolated coil, magnetic regulator, and pulse-startballasts are available (consult factory).

OPTICAL SYSTEMS

Prismatic polycarbonate refractor and internal reflector optimize efficiencyand light distribution.

INSTALLATION

Mount on any flat, non-combustible surface. Rear wiring entry for mountingover standard j-box. Multiple surface conduit entry hubs also provided.

LISTING

UL listed for wet locations (standard).

Series

TW6

Outdoor

Catalog Number

Notes Type

Wattage/lamp source

High pressure sodium70S

100S150S200S250S

Metal halide175M250M

Voltage

120208240277347480TB1

TB11

TB21

TB31

Ballast

(blank) Standard ballast (see above)RNP Reactor normal power

factorRHP Reactor high power factorXNP High reactance (lag) normal

power factorXHP High reactance (lag) high

power factorCWI CWI ballast

CWA CWA ballast

NOTE: SCWA ballast must be selectedto comply with California Title 20 metalhalide regulations. SCWA also may berequired to meet other states'regulations. Consult local authorities.SCWA SCWA pulse-start

Shipped installed in fixture

LPI Lamp included as standardPE Photoelectric cell, button type2,3

HSS Stainless steel externalhardware

SF Single 5-amp fuseDF Double 5-amp fuse

WG WireguardVG Vandal guard

Architectural colors(blank) Dark bronze finish (standard)

DBL Black finishDWH White finish

DGYG Gray finish

NOTES:1 Quad-tap ballast (120/208/240/277V wired to 277V. Factory wiring to other voltages is

available.2 Not available with 480V.3 Not available with multi-tap ballast.

TW6

Options

Roadway LightingWall -Mounted Underpass and Tunnel

TW670-250W HIGH PRESSURE SODIUM

70-250W METAL HALIDE

Sheet #: TW6-M-S RL-280

14-7/8"(378)

14-7/8"(378)

7" (179)

16-5/8"(424)

8-9/16"(251)

TW6 High Pressure Sodium and Metal Halide Roadway Lighting

Lithonia LightingOutdoor LightingOne Lithonia Way, Conyers, GA 30012Phone: 770-922-9000 Fax: 770-918-1209www.lithonia.com ©2004 Acuity Brands Lighting, Inc. 2/29/08Sheet #: TW6-M-S