Oscillographs
The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.A minor deflection of the mirror is routed through magnifying lens on photosensitive rolled paper for recording sensitive readings.
![Page 2: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/2.jpg)
Oscilloscope
![Page 3: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/3.jpg)
Cathode-ray-Tube
1. Three Electron guns (for red, green, and blue phosphor dots)2. Electron beams3. Focusing coils4. Deflection coils5. Anode connection
6. Mask for separating beams for red, green, and blue part of displayed image7. Phosphor layer with red, green, and blue zones8. Close-up of the phosphor-
coated inner side of the screen
![Page 4: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/4.jpg)
Electronic Gun
![Page 5: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/5.jpg)
Cathode Ray Tube
Cathode rays are so named because they are emitted by the negative electrode, or cathode, in a tube. To release electrons into the tube, they first must be detached from the atoms of the cathode. In early vacuum tubes (Crookes tubes) this was done solely by the high electrical potential between the anode and the cathode. In modern tubes this is assisted by making the cathode a thin wire filament and passing an electric current through it. The current heats the filament red hot. The increased random heat motion of the filament atoms assists in knocking electrons out of the atoms at the surface of the filament, into the evacuated space of the tube. This process is called thermionic emission and can reduce the anode to cathode voltage needed to obtain effective currents.
![Page 6: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/6.jpg)
Working of CRT
It works on the following principles :
(i)thermionic emission
(ii)deflection of the electron beam by the electric and magnetic field
(iii)fluorescence produced by the electron beam on a fluorescent screen
![Page 7: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/7.jpg)
CRT
![Page 8: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/8.jpg)
Electrodynamics
ay =eVd
md
yv
vx
vy
L
d
Ed
Vd
; vy = ayt = eVdL
mvxd
; = tan-1vy
vx
![Page 9: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/9.jpg)
Oscilloscopes
The signal travels directly to the vertical deflection plates of the cathode ray tube (CRT). Voltage applied to these deflection plates causes a glowing dot to move. (An electron beam hitting phosphor inside the CRT creates the glowing dot.) A positive voltage causes the dot to move up while a negative voltage causes the dot to move down.
![Page 10: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/10.jpg)
Oscilloscopes The signal also travels to the
trigger system to start or trigger a "horizontal sweep." Horizontal sweep is a term referring to the action of the horizontal system causing the glowing dot to move across the screen. Triggering the horizontal system causes the horizontal time base to move the glowing dot across the screen from left to right within a specific time interval. Many sweeps in rapid sequence cause the movement of the glowing dot to blend into a solid line. At higher speeds, the dot may sweep across the screen up to 500,000 times each second.
![Page 11: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/11.jpg)
Oscilloscopes
Together, the horizontal sweeping action and the vertical deflection action traces a graph of the signal on the screen. The trigger is necessary to stabilize a repeating signal. It ensures that the sweep begins at the same point of a repeating signal, resulting in a clear picture as shown in following figure.
![Page 12: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/12.jpg)
Oscilloscopes
Block Diagram
![Page 13: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/13.jpg)
Tutorial The force exerted on electrons beam by an electric field :
F = q.E
Where F is force in Newton. N
q is charge on electron in Coulomb,C
E is electric filed intensity in volt/meterWhen an anode voltage Va is applied to the accelerating
anode, the potential energy associated with an electron
having charge q is: PE = q.Va while
K.E.=½mv2
so the velocity of electron 52
5.93 10aa
qVv x V
m= =
![Page 14: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/14.jpg)
Tutorial
When such an electron enters a deflecting plate, the
velocity of electron motion in x-direction remains the same
through the deflecting plates, but in Y-direction: dy
VE
d=
Therefore the force in y- direction is and other variables are:
2 2
..
1 1
2 2
dy y
y
y dy
dy
qVF q E
dma
qE qVa
m mdqV
y a t tmd
= =
=
= =
= =
![Page 15: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/15.jpg)
Instrument Tape Recorder
![Page 16: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/16.jpg)
![Page 17: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/17.jpg)
Functional layout of tape recorder
![Page 18: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/18.jpg)
Applications
Tape speed Bandwidth Studio recording
38 cm/s (15 ips) 20 Hz–20 kHz High-quality home recording
19 cm/s (7½ ips) 30 Hz–15 kHz
40 Hz–13 kHz
General domestic music and speech
9.5 cm/s (3¾ ips) 30 Hz–15 kHz Recording speech (dictation)
![Page 19: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/19.jpg)
Industrial Tape Recorder
![Page 20: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/20.jpg)
Industrial Tape Recorder….
Tape recorders rely on magnetic tape to store data. Typically used for the recording and playback of voices or music, tape recorders have also been used for recording and storing computer information. Floppy and hard disks rely on the same principles of magnetic recording to store data as regular tape recorders use. Though this technology has been surpassed in recent years by laser-based recording processes, magnetic tape recording is still an affordable and widespread means of storing information.
![Page 21: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/21.jpg)
How it works
The recording process itself relies on the principles of magnetism. The tape recorder uses electromagnets (the heads) to apply a magnetic flux to the ferric oxide on the tape. Each electromagnet is made of an iron core wrapped with wire. There is a small gap in the electromagnet head which actually allows the recording to take place. When you press record on the machine, the audio data flows through the wire, creating a magnetic field around the iron core. Magnetic flux flows in to bridge the gap in the head of the electromagnet. The flux creates a particular pattern, and it magnetizes the ferric oxide in the tape as it rolls across the head. The ferric oxide instantly stores the sound by recording the pattern created by the flux.
![Page 22: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/22.jpg)
How it works …… Stereo tape recorders have two heads that in
combination span about half of the tape's width. Each records one channel, the end result being two channels recorded on half the tape. This enables you to turn the cassette over and to record another two separate channels on the other half of the tape's width. Due to this placement of the heads, most tape recorders enable you to record on side A and side B of a cassette without sound overlapping.
![Page 23: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/23.jpg)
Hyperlink
http://www.magnet.fsu.edu/education/tutorials/java/taperecorder/index.html
![Page 24: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/24.jpg)
Tape Recording Process
![Page 25: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/25.jpg)
Erase Head
Before passing over the record head, a tape in a recorder passes over the erase head which applies a high amplitude, high frequency AC magnetic field to the tape to erase any previously recorded signal and to thoroughly randomize the magnetization of the magnetic emulsion. Typically, the tape passes over the erase head immediately before passing over the record head. The gap in the erase head is wider than those in the record head; the tape stays in the field of the head longer to thoroughly erase any previously recorded signal.
![Page 26: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/26.jpg)
Tape Playback
When a magnetized tape passes under the playback head of a tape recorder, the ferromagnetic material in the tape head, magnetic field penetrates a coil of wire which is wrapped around it. Any change in magnetic field induces a voltage in the coil according to Faraday's law. This induced voltage forms an electrical image of the signal which is recorded on the tape.
![Page 27: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/27.jpg)
Problem The magnetization of the magnetic emulsion is
proportional to the recorded signal while the induced voltage in the coil is proportional to the rate at which the magnetization in the coil changes. This means that for a signal with twice the frequency, the output signal is twice as great for the same degree of magnetization of the tape. It is therefore necessary to compensate for this increase in signal to keep high frequencies from being boosted by a factor of two for each octave increase in pitch. This compensation process is called equalization.
![Page 28: Oscillographs The devices is used to measure very small quantities; i.e. microamperes. The deflection of moving coil is corded holding a small mirror.](https://reader036.fdocuments.in/reader036/viewer/2022062515/56649d1f5503460f949f3d44/html5/thumbnails/28.jpg)
Multi-channel Tape Head