ORVAL HYDRAULIC - CATALOGUE.pdf
-
Upload
tatiana-hernandez -
Category
Documents
-
view
123 -
download
11
Transcript of ORVAL HYDRAULIC - CATALOGUE.pdf
-
5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf
1/18
-
5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf
2/18
-
5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf
3/18
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-M40 1P
1
40 lt./min.
320
25
Max 30 micron
2,162
STANDART
P A-B T
3/8"
1/2"
3/8"
1/2"
3/8
1/2"
Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-M45 1P
1
45 lt./min.
320
25
Max 30 micron
3,15
STANDART
P A-B T
3/8"
1/2"
3/8"
1/2"
1/2"
1/2"
Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action / Carry-over
ORV-M40 1P
ORV-M45 1P
2
230
57
186
46
40
70
91,5
B
A
TP
TP
A
B
275
62
103
73
64
76
194
-
5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf
4/18
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-M45 2P
2
40 lt./min.
320
25
Max 30 micron
4,90
STANDART
P A-B T
3/8"
1/2"
3/8"
1/2"
1/2
1/2"
Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-M45 3P
3
45 lt./dk.
320
25
Max 30 micron
6,65
STANDART
P A-B T
3/8"
1/2"
3/8"
1/2"
1/2"
1/2"
Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over
ORV-M45 2P
ORV-M45 3P
3
275
62
P
B B
A A
T64
76
109
139
194
36
64
194
76 TP
BBB
AAA
175
145
36 36275
62
-
5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf
5/18
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-M45 4P
4
45 lt./min.
320
25
Max 30 micron
8,40
STANDART
P A-B T
3/8"
1/2"
3/8"
1/2"
1/2
1/2"
Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-M45 5P
5
45 lt./min.
320
25
Max 30 micron
10,15
STANDART
P A-B T
3/8"
1/2"
3/8"
1/2"
1/2"
1/2"
Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over
ORV-M45 4P
ORV-M45 5P
4
36 36 36
181
211
76
64
194
P
A A A A
T
B B B B
275
62
36 36 36 36
194
217
247
64
76 P T
B B B B B
A A A A A
275
62
-
5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf
6/18
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-M45 6P
6
45 lt./min.
320
25
Max 30 micron
11,9
STANDART
P A-B T
3/8"
1/2"
3/8"
1/2"
1/2
1/2"
Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-M80 1P
1
80 lt./min.
320
25
Max 30 micron
4,79
STANDART
P A-B T
1/2
3/4
1/2
3/4
3/4
3/4
Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over
ORV-M45 6P
ORV-M80 1P
5
194
36 36 36 36 36
64
76
253
283
P T
B B B B B B
A A A A A A
275
62
275
76 84
130
217
85
69P T
A
B
-
5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf
7/18
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-M80 2P
2
80 lt./min.
320
25
Max 30 micron
7,24
STANDART
P A-B T
1/2
3/4
1/2
3/4
3/4
3/4
Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-M80 3P
3
80 lt./min.
320
25
Max 30 micron
9,69
STANDART
P A-B T
1/2
3/4
1/2
3/4
3/4
3/4
Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over
ORV-M80 2P
ORV-M80 3P
6
275
76
217
45
175
129
69
85P T
B B
A A
275
76
217
45 45
69
85
174
220
P T
A A A
B B B
-
5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf
8/18
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-M80 4P
4
80 lt./min.
320
25
Max 30 micron
12,14
STANDART
P A-B T
1/2
3/4
1/2
3/4
3/4
3/4
Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-M80 5P
5
80 lt./min.
320
25
Max 30 micron
14,59
STANDART
P A-B T
1/2
3/4
1/2
3/4
3/4
3/4
Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over
ORV-M80 4P
ORV-M80 5P
7
275
76
217
69
85
45 45 45
219
265
P T
A A A A
B B B B
275
76
217
45 45 45 45
69
85
264
310
P T
B B B B B
A A A A A
-
5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf
9/18
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-M80 6P
6
80 lt./min.
320
25
Max 30 micron
17,04
STANDART
P A-B T
1/2
3/4
1/2
3/4
3/4
3/4
Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-PD80 1P
1
80 lt./min.
320
25
Max 30 micron
7,07
STANDART
P A-B T
1/2
3/4
1/2
3/4
3/4
3/4
Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over
ORV-M80 6P
ORV-PD80 1P
8
275
76
217
45 45 45 45 45
69
85
355
309
P T
B B B B B B
A A A A A A
284
95
240
63
88
133
P T
B
A
-
5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf
10/18
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-PD80 2P
2
80 lt./min.
320
25
Max 30 micron
10,17
STANDART
P A-B T
1/2
3/4
1/2
3/4
3/4
3/4
Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-PD80 3P
3
80 lt./min.
320
25
Max 30 micron
13,27
STANDART
P A-B T
1/2
3/4
1/2
3/4
3/4
3/4
Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over
ORV-PD80 2P
ORV-PD80 3P
9
284
95
240
63
44
177
132
P T
B B
A A
284
95
240
44 44
63
176
221
P T
B B B
A A A
-
5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf
11/18
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-PD80 4P
4
80 lt./min.
320
25
Max 30 micron
16,37
STANDART
P A-B T
1/2
3/4
1/2
3/4
3/4
3/4
Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-PD80 5P
5
80 lt./min.
320
25
Max 30 micron
19,47
STANDART
P A-B T
1/2
3/4
1/2
3/4
3/4
3/4
Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over
ORV-PD80 4P
ORV-PD80 5P
10
284
240
44 44 44
63
220
265
P T
B B B B
A A A A
95
284
95
63
240
44 44 44 44
264
309
P T
B B B B B
A A A A A
-
5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf
12/18
-
5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf
13/18
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-PD80 8P
8
80 lt./min.
320
25
Max 30 micron
28,77
STANDART
P A-B T
1/2
3/4
1/2
3/4
3/4
3/4
Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over
ORV-PD80 8P
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-PD150 1P
1
150 lt./min.
320
25
Max 30 micron
13,37
STANDART
P A-B T
3/4
1
3/4
1
1
1
Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over
ORV-PD150 1P
12
284
95
240
44 44 44 44 44 44 44
396
441
63P T
B B B B B B B B
A A A A A A A A
290
120
278
83P T
B
A
105
160
-
5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf
14/18
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-PD150 2P
2
150 lt./min.
320
25
Max 30 micron
19,41
STANDART
P A-B T
3/4
1
3/4
1
1
1
Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over
ORV-PD150 2P
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-PD150 3P
3
150 lt./min.
320
25
Max 30 micron
25,81
STANDART
P A-B T
3/4
1
3/4
1
1
1
Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over
ORV-PD150 3P
13
290
120
278
52.5
83P
B B
A A
T
157,5
212,5
290
120
278
52,5 52,5
83
210
P T
B B B
AA A
265
-
5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf
15/18
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-PD150 4P
4
150 lt./min.
320
25
Max 30 micron
32,21
STANDART
P A-B T
3/4
1
3/4
1
1
1
Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over
ORV-PD150 4P
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-PD150 5P
5
150 lt./min.
320
25
Max 30 micron
38,61
STANDART
P A-B T
3/4
1
3/4
1
1
1
Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over
ORV-PD150 5P
14
290
120
278
52,5 52,5 52,5
83
262,5
P T
B B B B
A A A A
317,5
290
120
278
52,5 52,5 52,5 52,5
315
P T
B B B B B
A A A A A
83
370
-
5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf
16/18
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-PD150 6P
6
150 lt./min.
320
25
Max 30 micron
45,01
STANDART
P A-B T
3/4
1
3/4
1
1
1
Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over
ORV-PD150 6P
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-PD150 7P
7
150 lt./min.
320
25
Max 30 micron
51,41
STANDART
P A-B T
3/4
1
3/4
1
1
1
Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-
over
ORV-PD150 7P
15
290
120
278
52,5 52,5 52,5 52,5 52,5
367,5
83P T
B B B B B B
A A A A A A
422,5
290
120
278
52,5 52,5 52,5 52,5 52,5 52,5
83
420
P T
B B B B B B B
A A A A A A A
475
-
5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf
17/18
Product Code
Section
Displacement
Maximum Working Pressure
Maximum Ret. Back Pressure
Recommended Oil Filter
Kg.
ORV-PD150 8P
8
150 lt./min.
320
25
Max 30 micron
57,81
STANDART
P A-B T
3/4
1
3/4
1
1
1
Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over
ORV-PD150 8P
16
STANDART
A-B
1/4"
Pneumatic Control Valve
290
120
278
52,5 52,5 52,5 52,5 52,5 52,5 52,5
83
472,5
P T
B B B B B B B B
A A A A A A A A
527,5
27
3555
50
29,
5
79,
5 A
B
-
5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf
18/18