ORVAL HYDRAULIC - CATALOGUE.pdf

download ORVAL HYDRAULIC - CATALOGUE.pdf

of 18

Transcript of ORVAL HYDRAULIC - CATALOGUE.pdf

  • 5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf

    1/18

  • 5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf

    2/18

  • 5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf

    3/18

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-M40 1P

    1

    40 lt./min.

    320

    25

    Max 30 micron

    2,162

    STANDART

    P A-B T

    3/8"

    1/2"

    3/8"

    1/2"

    3/8

    1/2"

    Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-M45 1P

    1

    45 lt./min.

    320

    25

    Max 30 micron

    3,15

    STANDART

    P A-B T

    3/8"

    1/2"

    3/8"

    1/2"

    1/2"

    1/2"

    Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action / Carry-over

    ORV-M40 1P

    ORV-M45 1P

    2

    230

    57

    186

    46

    40

    70

    91,5

    B

    A

    TP

    TP

    A

    B

    275

    62

    103

    73

    64

    76

    194

  • 5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf

    4/18

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-M45 2P

    2

    40 lt./min.

    320

    25

    Max 30 micron

    4,90

    STANDART

    P A-B T

    3/8"

    1/2"

    3/8"

    1/2"

    1/2

    1/2"

    Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-M45 3P

    3

    45 lt./dk.

    320

    25

    Max 30 micron

    6,65

    STANDART

    P A-B T

    3/8"

    1/2"

    3/8"

    1/2"

    1/2"

    1/2"

    Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over

    ORV-M45 2P

    ORV-M45 3P

    3

    275

    62

    P

    B B

    A A

    T64

    76

    109

    139

    194

    36

    64

    194

    76 TP

    BBB

    AAA

    175

    145

    36 36275

    62

  • 5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf

    5/18

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-M45 4P

    4

    45 lt./min.

    320

    25

    Max 30 micron

    8,40

    STANDART

    P A-B T

    3/8"

    1/2"

    3/8"

    1/2"

    1/2

    1/2"

    Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-M45 5P

    5

    45 lt./min.

    320

    25

    Max 30 micron

    10,15

    STANDART

    P A-B T

    3/8"

    1/2"

    3/8"

    1/2"

    1/2"

    1/2"

    Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over

    ORV-M45 4P

    ORV-M45 5P

    4

    36 36 36

    181

    211

    76

    64

    194

    P

    A A A A

    T

    B B B B

    275

    62

    36 36 36 36

    194

    217

    247

    64

    76 P T

    B B B B B

    A A A A A

    275

    62

  • 5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf

    6/18

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-M45 6P

    6

    45 lt./min.

    320

    25

    Max 30 micron

    11,9

    STANDART

    P A-B T

    3/8"

    1/2"

    3/8"

    1/2"

    1/2

    1/2"

    Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-M80 1P

    1

    80 lt./min.

    320

    25

    Max 30 micron

    4,79

    STANDART

    P A-B T

    1/2

    3/4

    1/2

    3/4

    3/4

    3/4

    Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over

    ORV-M45 6P

    ORV-M80 1P

    5

    194

    36 36 36 36 36

    64

    76

    253

    283

    P T

    B B B B B B

    A A A A A A

    275

    62

    275

    76 84

    130

    217

    85

    69P T

    A

    B

  • 5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf

    7/18

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-M80 2P

    2

    80 lt./min.

    320

    25

    Max 30 micron

    7,24

    STANDART

    P A-B T

    1/2

    3/4

    1/2

    3/4

    3/4

    3/4

    Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-M80 3P

    3

    80 lt./min.

    320

    25

    Max 30 micron

    9,69

    STANDART

    P A-B T

    1/2

    3/4

    1/2

    3/4

    3/4

    3/4

    Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over

    ORV-M80 2P

    ORV-M80 3P

    6

    275

    76

    217

    45

    175

    129

    69

    85P T

    B B

    A A

    275

    76

    217

    45 45

    69

    85

    174

    220

    P T

    A A A

    B B B

  • 5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf

    8/18

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-M80 4P

    4

    80 lt./min.

    320

    25

    Max 30 micron

    12,14

    STANDART

    P A-B T

    1/2

    3/4

    1/2

    3/4

    3/4

    3/4

    Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-M80 5P

    5

    80 lt./min.

    320

    25

    Max 30 micron

    14,59

    STANDART

    P A-B T

    1/2

    3/4

    1/2

    3/4

    3/4

    3/4

    Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over

    ORV-M80 4P

    ORV-M80 5P

    7

    275

    76

    217

    69

    85

    45 45 45

    219

    265

    P T

    A A A A

    B B B B

    275

    76

    217

    45 45 45 45

    69

    85

    264

    310

    P T

    B B B B B

    A A A A A

  • 5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf

    9/18

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-M80 6P

    6

    80 lt./min.

    320

    25

    Max 30 micron

    17,04

    STANDART

    P A-B T

    1/2

    3/4

    1/2

    3/4

    3/4

    3/4

    Parallel &Series Circuit - Adjustable DirectOperated Relief Valve - Single /Load Hold CheckValve in Each Section/ Double Action Carry-over

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-PD80 1P

    1

    80 lt./min.

    320

    25

    Max 30 micron

    7,07

    STANDART

    P A-B T

    1/2

    3/4

    1/2

    3/4

    3/4

    3/4

    Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over

    ORV-M80 6P

    ORV-PD80 1P

    8

    275

    76

    217

    45 45 45 45 45

    69

    85

    355

    309

    P T

    B B B B B B

    A A A A A A

    284

    95

    240

    63

    88

    133

    P T

    B

    A

  • 5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf

    10/18

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-PD80 2P

    2

    80 lt./min.

    320

    25

    Max 30 micron

    10,17

    STANDART

    P A-B T

    1/2

    3/4

    1/2

    3/4

    3/4

    3/4

    Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-PD80 3P

    3

    80 lt./min.

    320

    25

    Max 30 micron

    13,27

    STANDART

    P A-B T

    1/2

    3/4

    1/2

    3/4

    3/4

    3/4

    Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over

    ORV-PD80 2P

    ORV-PD80 3P

    9

    284

    95

    240

    63

    44

    177

    132

    P T

    B B

    A A

    284

    95

    240

    44 44

    63

    176

    221

    P T

    B B B

    A A A

  • 5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf

    11/18

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-PD80 4P

    4

    80 lt./min.

    320

    25

    Max 30 micron

    16,37

    STANDART

    P A-B T

    1/2

    3/4

    1/2

    3/4

    3/4

    3/4

    Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-PD80 5P

    5

    80 lt./min.

    320

    25

    Max 30 micron

    19,47

    STANDART

    P A-B T

    1/2

    3/4

    1/2

    3/4

    3/4

    3/4

    Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over

    ORV-PD80 4P

    ORV-PD80 5P

    10

    284

    240

    44 44 44

    63

    220

    265

    P T

    B B B B

    A A A A

    95

    284

    95

    63

    240

    44 44 44 44

    264

    309

    P T

    B B B B B

    A A A A A

  • 5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf

    12/18

  • 5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf

    13/18

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-PD80 8P

    8

    80 lt./min.

    320

    25

    Max 30 micron

    28,77

    STANDART

    P A-B T

    1/2

    3/4

    1/2

    3/4

    3/4

    3/4

    Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over

    ORV-PD80 8P

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-PD150 1P

    1

    150 lt./min.

    320

    25

    Max 30 micron

    13,37

    STANDART

    P A-B T

    3/4

    1

    3/4

    1

    1

    1

    Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over

    ORV-PD150 1P

    12

    284

    95

    240

    44 44 44 44 44 44 44

    396

    441

    63P T

    B B B B B B B B

    A A A A A A A A

    290

    120

    278

    83P T

    B

    A

    105

    160

  • 5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf

    14/18

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-PD150 2P

    2

    150 lt./min.

    320

    25

    Max 30 micron

    19,41

    STANDART

    P A-B T

    3/4

    1

    3/4

    1

    1

    1

    Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over

    ORV-PD150 2P

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-PD150 3P

    3

    150 lt./min.

    320

    25

    Max 30 micron

    25,81

    STANDART

    P A-B T

    3/4

    1

    3/4

    1

    1

    1

    Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over

    ORV-PD150 3P

    13

    290

    120

    278

    52.5

    83P

    B B

    A A

    T

    157,5

    212,5

    290

    120

    278

    52,5 52,5

    83

    210

    P T

    B B B

    AA A

    265

  • 5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf

    15/18

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-PD150 4P

    4

    150 lt./min.

    320

    25

    Max 30 micron

    32,21

    STANDART

    P A-B T

    3/4

    1

    3/4

    1

    1

    1

    Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over

    ORV-PD150 4P

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-PD150 5P

    5

    150 lt./min.

    320

    25

    Max 30 micron

    38,61

    STANDART

    P A-B T

    3/4

    1

    3/4

    1

    1

    1

    Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over

    ORV-PD150 5P

    14

    290

    120

    278

    52,5 52,5 52,5

    83

    262,5

    P T

    B B B B

    A A A A

    317,5

    290

    120

    278

    52,5 52,5 52,5 52,5

    315

    P T

    B B B B B

    A A A A A

    83

    370

  • 5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf

    16/18

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-PD150 6P

    6

    150 lt./min.

    320

    25

    Max 30 micron

    45,01

    STANDART

    P A-B T

    3/4

    1

    3/4

    1

    1

    1

    Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over

    ORV-PD150 6P

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-PD150 7P

    7

    150 lt./min.

    320

    25

    Max 30 micron

    51,41

    STANDART

    P A-B T

    3/4

    1

    3/4

    1

    1

    1

    Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-

    over

    ORV-PD150 7P

    15

    290

    120

    278

    52,5 52,5 52,5 52,5 52,5

    367,5

    83P T

    B B B B B B

    A A A A A A

    422,5

    290

    120

    278

    52,5 52,5 52,5 52,5 52,5 52,5

    83

    420

    P T

    B B B B B B B

    A A A A A A A

    475

  • 5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf

    17/18

    Product Code

    Section

    Displacement

    Maximum Working Pressure

    Maximum Ret. Back Pressure

    Recommended Oil Filter

    Kg.

    ORV-PD150 8P

    8

    150 lt./min.

    320

    25

    Max 30 micron

    57,81

    STANDART

    P A-B T

    3/4

    1

    3/4

    1

    1

    1

    Parallel & Series Circuit / Adjustable DirectOperated Relief Valve / Load Hold Check Valvein Each Section / Single - Double Action Carry-over

    ORV-PD150 8P

    16

    STANDART

    A-B

    1/4"

    Pneumatic Control Valve

    290

    120

    278

    52,5 52,5 52,5 52,5 52,5 52,5 52,5

    83

    472,5

    P T

    B B B B B B B B

    A A A A A A A A

    527,5

    27

    3555

    50

    29,

    5

    79,

    5 A

    B

  • 5/20/2018 ORVAL HYDRAULIC - CATALOGUE.pdf

    18/18