17
CN ePMP OG 09242013 1000 Ordering Guide ePMP 1000 CONNECTORIZED RADIO WITH SYNC ePMP 1000 INTEGRATED RADIO

description

Ordering Guide EPMP 09242013

Transcript of Ordering Guide EPMP 09242013

  • CN ePMP OG 09242013

    1000 Ordering Guide

    ePMP 1000 CONNECTORIZED RADIO WITH SYNCePMP 1000 INTEGRATED RADIO

  • 2cambium networks

    CN ePMP OG 09242013

    ordering Guide: 1000 Integrated Radio & 1000 Connectorized Radio with Sync

    1.0 Introduction 3

    2.0 Ordering Connectorized Synchronized Radios 6

    2.1 Connectorized Synchronized Radios 6

    2.2 AP Sector Antenna Options 7

    2.3 Power Supply for Connectorized, Synchronized Radio 7

    2.4 Surge Suppression 8

    2.5 GPS Synchronization 8

    2.6 Extended Warranties 9

    3.0 Ordering Integrated Radios 10

    3.1 Integrated Radio Modules 10

    3.2 Power Supply for Integrated Radio 11

    3.3 Surge Suppression 11

    3.4 Cabling and Accessories 12

    3.5 Extended Warranties 12

    4.0 AP and SM Installation Examples 13

    4.1 ePMP Radio Mounted an a Tower 13

    4.2 ePMP Radio on a Residential or Commercial Building 14

    4.3 ePMP Radio on a Rooftop 15

    4.4 ePMP Radio Module Grounding and Protection 16

  • 3cambium networks

    CN ePMP OG 09242013

    ordering Guide: 1000 Integrated Radio & 1000 Connectorized Radio with Sync

    1 IntroductionTHIS ORDERING GuIDE covers the Cambium ePMP Platform. It is intended to provide a structured guide to ordering a solution with any accessories and ancillary items for a successful installation.

    The key steps involved in planning and ordering your system are:

    1 REGulATORY PlANNING: To begin, you need to contact the applicable radio regulator in your area to identify any restrictions or limitation imposed on radio equipment operat-ing in your planned RF band and to determine whether or not you need to register your

    PMP network. As the user of the radio equipment, it is your responsibility to ensure that

    your system complies with any regulatory guidelines imposed by the local regulator.

    2 SITE PlANNING: We recommend that you complete a site survey to identify the many considerations critical for successful site selection such as the availability of tower or rooftop space, the location of the grounding system, best positioning of the APs, SMs

    and BHs, aesthetics and other permission-based issues, and maximum cable lengths

    required for your deployment.

    3 lINk AND SECTOR PlANNING: You need to determine link and sector-planning factors such as path obstructions, risk of interference, path and link loss, maximum power levels permitted, and coverage requirements.

    4 SPECTRuM ANAlYSIS: One of the most important elements in your planning process is the analysis of spectrum usage and signal strength needed to occupy the spectrum you are planning to use. For a PMP system, you need to plan your sector coverage to determine

    how many APs will be needed and what sector size will be required to provide adequate

    coverage for the deployment. For PTP links you need to determine whether there is

    available spectrum to accomplish your desired goal.

    5 PREPARING AN EPMP ORDER: Once you have identified all the regulatory requirements and planned the site, link, sector coverage and spectrum requirements, you are ready to compile your order. This Ordering Guide provides the part numbers, product descrip-

    tions, instructions, and resources to help you complete an ePMP order.

  • 4cambium networks

    CN ePMP OG 09242013

    ordering Guide: 1000 Integrated Radio & 1000 Connectorized Radio with Sync

    uNSYNCHRONIZED

    SYNCHRONIZED & uNSYNCHRONIZED

    SYNCHRONIZED & uNSYNCHRONIZED

    PMP

    PTP lINkS

    PTP lINkS

    Deployment Configurations

    The ePMP Solution is very versatile. Each of the radio units can be configured to be an Access Point,

    a Subscriber Module or a Point to Point radio. When the connectorized radio is combined with an

    external antenna, a wide variety of configurations can be supported with the solution.

    The figure below illustrates the different configurations that can be deployed.

  • 5cambium networks

    CN ePMP OG 09242013

    ordering Guide: 1000 Integrated Radio & 1000 Connectorized Radio with Sync

    When you are ready to prepare your order, the following equipment components can be selected

    for an ePMP network.

    ePMP System Components

    ePMP Connectorized Radio with Sync ePMP Integrated Radio

    If CONfIGuRED AS AN ACCESS POINT: Determine the Number of Radios Required based on the coverage area and the sector configuration (90 degree or 120 degree) selected

    If CONfIGuRED AS PTP RADIO: Determine the Number of Radios Required based on the num-ber of links needed

    If CONfIGuRED AS A SubSCRIbER MODulE: Determine the Number of SMs required

    If CONfIGuRED AS AN ACCESS POINT: Determine the Number of Radios Required based on the cover-age area. The integrated antenna has a beam width of approxi-mately 24 degrees

    If CONfIGuRED AS PTP RADIO: Determine the Number of Radios Required based on the num-ber of links needed

    POWER SuPPlY: A 30 V Power Supply which allows for Gigabit Ethernet opera-tion is included with the Radio

    Alternatively, the Radio can be powered by the Cambium CMM3 and CMM4 or a third party 802.3af compliant powering device

    POWER SuPPlY: A 30 V Power Supply which allows for Fast Ethernet operation is included with the Radio

    Alternatively, the Radio can be powered by any of the PMP100 or PMP4X0 SM Power Supplies

    ANTENNA: 4-sector dual polarity (H+V) 3-sector dual polarity (H+V) Alternative configuration (verify regulations prior to purchase)

    ANTENNA: The ePMP Integrated radio includes a 13 dBi, 24 degree antenna

    SuRGE SuPPRESSOR: The Connectorized, Synchronized radios include built-in surge suppression no external suppression is required at the device

    SHOulD ADD ExTERNAl uNITS AT: Cable entrance point leading to Building entrance

    On the bottom of the tower/pole near the grounding bar

    If the Ethernet connection of the Radio is to be operated in 10/100 Mbps mode, then the 600SSH Surge suppressor can be utilized. Otherwise a 3rd party gigabit Ethernet compatible surge suppressor should be used. Such a surge suppressor (Models # AL-CAT6JW and AL-CAT6HPJW) is available from L-Com.

    SuRGE SuPPRESSOR: The Integrated radios include built-in surge suppression no external suppression is required at the device

    SHOulD ADD ExTERNAl uNITS (600SSH) AT:

    Cable entrance point leading to Building entrance

    On the bottom of the tower/pole near the grounding bar (if deployed on a tower)

    CAblING AND ACCESSORIES: Cat 5e cables Grounding cables Connectors

    CAblING AND ACCESSORIES: Cat 5e cables Grounding cables Connectors

    ExTENDED WARRANTY: One additional year of coverage Two additional years of coverage Four additional years of coverage

    ExTENDED WARRANTY: One additional year of coverage Two additional years of coverage Four additional years of coverage

  • 6cambium networks

    CN ePMP OG 09242013

    ordering Guide: 1000 Integrated Radio & 1000 Connectorized Radio with Sync

    2 Ordering Connectorized Radio with Sync

    2.1 Connectorized Synchronized Radios

    Each module contains both radio and networking electronics supplied in a connectorized configura-

    tion for use with an external antenna. Connectorized modules with external antennas are designed to

    cope with more difficult radio conditions. When configured as an Access Point and operating in a 20

    MHz channel configuration, each connectorized, synchronized radio module can provide a capacity

    of up to 100 Mbps. As an Access Point, the module can support up to 120 SMs. For an optimal per-

    forming system, it is recommended that no more than 60 SMs be connected to one Access Point.

    Part Number Description

    C050900A011AePMP 1000: 5 GHz Connectorized Radio with

    Sync (ROW)

    C058900A112AePMP 1000: 5 GHz Connectorized Radio with

    Sync (FCC)

    C050900A013AePMP 1000: 5 GHz Connectorized Radio with

    Sync (EU)

    The images below shows what is included in the box when a Connectorized Radio is purchased:

    GPS Synchronized Connectorized Radio

    ePMP AP Radio unit ePMP AP Radio Antenna

    GPS AntennaPower Supply Power Cord

    (us/fcc Model Only)

    Radio Module

  • 7cambium networks

    CN ePMP OG 09242013

    ordering Guide: 1000 Integrated Radio & 1000 Connectorized Radio with Sync

    2.2 AP Sector Antenna Options

    When combined with a sector antenna, the Connectorized Synchronized Radio can provide a

    specific area of coverage. ePMP APs are connectorized radios and can support any coverage you

    need. However, we recommend using the ePMP with the high-performance antennas that have been

    developed specifically for the ePMP product either a 4-sector or a 3-sector dual polarity (H+V)

    antenna. These antennas have been specially engineered to be of high quality and have the required

    Front to Back ratio needed to enable frequency reuse. In particular, we recommend the use of the

    90 degree sector antenna. With the recommended Cambium antenna, a four sector ePMP site can

    be built using only two frequency channels. This provides the optimum level of spectrum efficiency.

    Your individual network and configuration may require a different sector width. In that case, third

    party antennas may be utilized to meet that need. If alternative configurations are needed, be sure

    that local regulations are followed prior to purchase.

    In the event that you choose to utilize a third party antenna, please note that the cable required to

    connect the AP to the antenna is not included and must be purchased separately. The connectors

    on the ePMP Connectorized radio are of the RP-SMA (Reverse Polarity Subminiature version A)

    type. Many third party antennas utilize N type connectors. A cable that will convert between these

    connector formats will be required and are readily available from a variety of suppliers.

    Part Number Description

    C050900D003A ePMP 1000: 5 GHz Sector 90 Antenna

    C050900D002A ePMP 1000: 5 GHz Sector 120 Antenna

    2.3 Power Supply for Connectorized, Synchronized Radio

    Each ePMP Radio requires a power supply to generate the supply voltage from the external DC

    source and inject the voltage into the radio. The power supply connects to the radio and network

    equipment via Cat 5e cable with RJ45 connectors.

    The radio comes with a 30V Power supply which supports Gigabit Ethernet operation on the Cat

    5e cable. The radio supports an input voltage range of 23 56 V and the PoE interface is 802.3af

    compliant. There is a variety of alternative powering methods that can be used. The Connectorized,

    Synchronized radio can be powered from either the Cambium CMM3 or CMM4 devices. Alternative-

    ly, the radio can be powered by 802.3af PoE compliant switches.

  • 8cambium networks

    CN ePMP OG 09242013

    ordering Guide: 1000 Integrated Radio & 1000 Connectorized Radio with Sync

    While the radio comes with a power supply included, it may be necessary to purchase spare power

    supplies. Spare power supplies can be purchased by ordering the following part number:

    Part Number Description

    N000900L001AePMP 1000: Spare Power Supply for Radio

    with Gigabit Ethernet (no cord)

    When selecting the location for the power supply, the following factors should be considered:

    Indoor location with no possibility of condensation

    Availability of main electricity supply

    Accessibility for connecting Ethernet cables

    Cable lengths the maximum permitted length of the copper Ethernet interface cable is 330

    feet (100 m) from the radio to the power source.

    2.4 Surge Suppression

    Because each connectorized, integrated radio includes a built-in surge suppressor, no external surge

    suppression unit is required at the radio module. However, you should include a surge suppressor at

    the buildings cable entrance point leading to the indoor power supply. If the Connectorized, syn-

    chronized radio is tower-mounted, you may also want to include a surge suppressor at the bottom

    of the tower near the tower ground bar.

    Part Number Description

    600SSD Surge Suppressor

    2.5 GPS Synchronization

    GPS synchronization is essential in most networks to avoid self-interference and maintain efficient

    use of available spectrum. There are a number of options to provide the network with the timing

    pulse that maintains network synchronization.

    Each GPS Synchronized, Connectorized radio has a built in GPS receiver and can on its own receive

    the required timing if the included, external GPS antenna is connected. The included GPS antenna

    has a cable that is 1m in length. The Cambium Sector antennas have a location at the top of the sec-

    tor antenna where the GPS antenna module can be installed. Alternatively, the GPS antenna can be

    located away from the radio. An extension cable (not included) with a maximum length of 2 m can

    be utilized to extend the distance of the antenna location from the radio.

  • 9cambium networks

    CN ePMP OG 09242013

    ordering Guide: 1000 Integrated Radio & 1000 Connectorized Radio with Sync

    Alternatively, the Cambium CMM3, CMM4 or compatible third party synchronization solution can be

    used to provide power and timing to the GPS Synchronized, Connectorized radio. Part numbers for

    the Cambium solutions are provided below. (Note that the Cambium Universal GPS (UGPS) module

    cannot be used with the ePMP solution.)

    Part Number Description

    1070CKDB CMM Micro (Outdoor Enclosure)

    1090CKBACMM4 with Ruggedized Switch and GPS (Outdoor

    Enclosure)

    1091AA CMM4 No Switch (Outdoor Enclosure)

    1092AA CMM4 Rack Mount Assembly

    2.6 Extended Warranties

    With the purchase of each ePMP GPS Synchronized radio, you have a 12-month (one-year) limited

    warranty on hardware components. This Standard Warranty also includes minor software enhance-

    ments as available and access to technical support.

    At the time of purchase or any time prior to the end of the 12-month Standard Warranty, we rec-

    ommend that you purchase an Extended Warranty to extend your equipment coverage and protect

    your investment. You have the option of purchasing an Extended Warranty for one, two, or four

    additional years of coverage. After the expiration of the 12-month Standard Warranty users of the

    ePMP will be required to purchase a Software Maintenance contract in order to continue to have

    access to new Software loads containing minor enhancements and technical support. Part numbers

    for those services will be available at a later date.

    Part Number Description

    C050900S101A ePMP Sync Radio Extended Warranty, 1 Additional Year

    C050900S102AePMP Sync Radio Extended Warranty, 2 Additional

    Year

    C050900S104AePMP Sync Radio Extended Warranty, 4 Additional

    Year

  • 10

    cambium networks

    CN ePMP OG 09242013

    ordering Guide: 1000 Integrated Radio & 1000 Connectorized Radio with Sync

    3 Ordering Integrated Radios

    3.1 Integrated Radio Modules

    Each integrated radio module is a self-contained unit that houses the radio and networking elec-

    tronics and is supplied in an integrated antenna configuration. This radio module can be configured

    to be an Access Point, Subscriber Module or Point to Point Radio Module. It will most often be con-

    figured to be a Subscriber Module.

    Part Number Description

    C050900C031A ePMP 1000: 5 GHz Integrated Radio (ROW)

    C058900C132A ePMP 1000: 5 GHz Integrated Radio (FCC)

    C050900C033A ePMP 1000: 5 GHz Integrated Radio (EU)

    The images below shows what is included in the box when an Integrated Connectorized Radio is

    purchased:

    Unsynchronized Integrated radio

    ePMP Integrated Radio Module

    Mounting StrapPower Supply Power Cord

    (us/fcc Model Only)

    Radio Module

  • 11

    cambium networks

    CN ePMP OG 09242013

    ordering Guide: 1000 Integrated Radio & 1000 Connectorized Radio with Sync

    3.2 Power Supply for Integrated Radio

    Each ePMP Radio requires a power supply to generate the supply voltage from the external DC

    source and inject the voltage into the radio. The power supply connects to the radio via Cat 5e ca-

    ble with RJ45 connectors.

    The radio comes with a 30V Power supply which supports 10/100 Mbps Ethernet operation on the

    Cat 5e cable. The radio supports an input voltage range of 24 30 V. The radio modules can also

    be powered by any of the power supply modules that provide power for the PMP100 and PMP4X0

    Subscriber Modules (ACPSSW-09B, -10B, -11B, -12C, -13B, -14V).

    While the radio comes with a power supply included, it may be necessary to purchase spare power

    supplies. Spare power supplies can be purchased by ordering the following part number:

    Part Number Description

    N000900L002AePMP 1000: Spare Power Supply for Radio with

    100Mbit Ethernet (no cord)

    When selecting the location for the power supply, the following factors should be considered:

    Indoor location with no possibility of condensation

    Availability of mains electricity supply

    Accessibility for connecting Ethernet cables

    Cable lengths the maximum permitted length of the copper Ethernet interface cable is 330

    feet (100 m) from the radio module to the power supply.

    3.3 Surge Suppression

    Each integrated radio module includes a built-in surge suppressor, so no external surge suppression

    unit is required at the radio module. However, you should include a surge suppressor at the build-

    ings cable entrance point leading to the indoor power supply. If the radio is tower-mounted, you

    may also want to include a surge suppressor at the bottom of the tower near the tower ground bar.

    Part Number Description

    600SSD Surge Suppressor

  • 12

    cambium networks

    CN ePMP OG 09242013

    ordering Guide: 1000 Integrated Radio & 1000 Connectorized Radio with Sync

    3.4 Cabling and Accessories

    In addition to the components above, you will need to order your cables and other accessories as

    needed to complete your AP order. The following is an optional pole mounting kit that could be

    used with the ePMP.

    Part Number Description

    SMMB1A Universal Mounting Kit

    3.5 Extended Warranties

    With the purchase of each ePMP Integrated radio, you have a 12-month (one-year) limited warranty

    on hardware components. This Standard Warranty also includes minor software enhancements as

    available.

    At the time of purchase or any time prior to the end of the 12-month Standard Warranty, we rec-

    ommend that you purchase an Extended Warranty to extend your equipment coverage and protect

    your investment. You have the option of purchasing an Extended Warranty for one, two, or four

    additional years of coverage. After the expiration of the 12-month Standard Warranty users of the

    ePMP will be required to purchase a Software Maintenance contract in order to continue to have

    access to new Software loads containing minor enhancements and technical support. Part numbers

    for those services will be available at a later date.

    Part Number Description

    C050900S001AePMP Integrated Radio Extended Warranty, 1 Additional

    Year

    C050900S002AePMP Integrated Radio Extended Warranty, 2 Additional

    Years

    C050900S004AePMP Integrated Radio Extended Warranty, 4 Additional

    Years

  • 13

    cambium networks

    CN ePMP OG 09242013

    ordering Guide: 1000 Integrated Radio & 1000 Connectorized Radio with Sync

    4 AP and SM Installation Examples

    This section provides illustrations showing the placement of ePMP systems with their ancillary com-

    ponents, cables, and accessories.

    4.1 ePMP Radio Mounted on a Tower

    AP/SM

    Equipment building

    Ground Ring

    NETWORkSWITCH

    SuRGE SuPPRESSOR

    POWERSuPPlY

    External Ground bar

    Legend

    Outdoor CAT5e cable: shielded with copper-plated steel

    Tower/building ground system

    CAT5e cable

    Ground Cable

  • 14

    cambium networks

    CN ePMP OG 09242013

    ordering Guide: 1000 Integrated Radio & 1000 Connectorized Radio with Sync

    4.2 ePMP Radio on a Residential or Commercial Building

    AP/SMEquipment building

    Ground Ring

    NETWORkSWITCH

    600SSDPOWERSuPPlY

    External Ground bar

    Legend

    Outdoor CAT5e cable: shielded with copper-plated steel

    building ground system

    CAT5e cable

    Ground Cable

  • 15

    cambium networks

    CN ePMP OG 09242013

    ordering Guide: 1000 Integrated Radio & 1000 Connectorized Radio with Sync

    4.3 ePMP Radio on a Rooftop

    AP

    building Ground Ring

    To Equipment Area

    Air Terminal (finial)

    Tower Grounding Conductor

    AC

    Service

    600SSD

    Legend

    Outdoor CAT5e cable: shielded with copper-plated steel

    building ground system

    Ground Cable

  • 16

    cambium networks

    CN ePMP OG 09242013

    ordering Guide: 1000 Integrated Radio & 1000 Connectorized Radio with Sync

    4.4 ePMP Radio Module Grounding and Protection

    Equipment building

    Mounting bracket

    24-Volt DC Wall Mount

    Customers Computer

    Subscriber Module

    CAT-5 Outdoor Cable

    10 AWG Copper Grounding Conductors per NEC 810-21

    Power Service Ground Electrode or 8-foot Ground Rod

    600SS SuRGE SuPPRESSOR

    POWER SERVICE PANEl

  • CN ePMP OG 09242013

    www.cambiumnetworks.com

    Cambium Networks and the stylized circular logo are trademarks of Cambium Networks, Ltd. All other trademarks are the property of their respective owners. Copyright 2013 Cambium Networks, Ltd. All rights reserved.ePMP-01 OG 082212

    For more information about configuring, ordering, and installing ePMP systems, refer to the ePMP Quick Start, Installation and User Guides.