Optoboards dependence on Temperature

28
Optoboards dependence on Temperature C. Gemme , T.Flick detector meeting, April 2 nd 2009 Motivations Test in SR1 thanks to K. Lantzsch, L.Masetti, J.Moss, S. Strandberg for helping in setting up the system Conclusions

description

Optoboards dependence on Temperature. Motivations Test in SR1 thanks to K. Lantzsch, L.Masetti, J.Moss, S. Strandberg for helping in setting up the system Conclusions. C. Gemme , T.Flick detector meeting, April 2 nd 2009. Opto Temperature dependence in 2008. - PowerPoint PPT Presentation

Transcript of Optoboards dependence on Temperature

Page 1: Optoboards dependence on Temperature

Optoboards dependence on Temperature

C. Gemme, T.Flickdetector meeting, April 2nd 2009

Motivations Test in SR1

thanks to K. Lantzsch, L.Masetti, J.Moss, S. Strandberg for helping in setting up the system

Conclusions

Page 2: Optoboards dependence on Temperature

Opto Temperature dependence in 2008

• We have some experience of temperature dependence in the pit:1. In early August Opto BPR set to 3.5 bar (~-5C );

optoheater setting to 5C. Optoboards temperature ~5-10 C: Many problems in operating the detector! Precise

quantification is difficult as the optotuning procedure was also not optimized yet.

2. BOC Scans vs temperature settings on part of the detector (Sep 9/10): Only 6 PP0s all failing at 10C Optoheaters settings at ~10C-13C-16C-19C-22C Data not exactly what we need: 2D scans with some

optotuning in between potentially changing Viset, etc..

DECIDED TO REDO THE TEST IN SR1

Page 3: Optoboards dependence on Temperature

SR1 test (March 27/28)• Setup

• 14 optoboards with 71 modules enabled (19 modules disabled due to various problems)

• Optoheaters to warm up (careful not to hit the software interlock) • Chiller to go down in opto temperature

• Scans => ~40 min for each set of measurement including reaching temp stabilityInlink/Outlink: BOC_INLINKOUTLINK, Base.2D_DSP: BOC_THR_DEL_DSP, Preset (DEL 0-24 in 25 steps, THR 50-250

in 21 steps)3D_DSP: BOC_THR_DEL_DSP, Optotest_3D (same as 2D, 15 Viset steps

650-1000)3D_FAST: BOC_THR_DEL_FAST, Optotest_3D (same as 2D, 8 Viset steps

650-1000)2D_DSP done only because the analysis should be ready to compare different scans

• Procedure• Day 1: from nominal Temp, go up in temperature with optoheaters• Day 2: from minimum T to nominal by varying the chiller set T

Page 4: Optoboards dependence on Temperature

Day 1 warm tests• Optoheaters powered by deskop PS. No DCS control, no feedback… not very safe• Not possible to go up to higher optoboard temperatures as there is a software

interlock at 35C (and a hardware at 40C). B boards went were close to the maximum. • Temperature changes during the scans due to scan on Viset changing VDC_current.

Meaurement Optoheaters V Chiller Mean T opto (D/B)

#1 OFF OFF ~26/~28.5C

#2 11 V OFF ~28C/~30.5C

#3 15 V OFF ~30C, ~32C

30

20

30

35 interlock

#1

#2#3

#1#2

#3

Page 5: Optoboards dependence on Temperature

Day2: cold tests

• Hygronometer to check the dew point (-15C inside the ~sealed Toothpix setup).

• Minimum temperature reachable by the chiller -23C and not very efficient thermal coupling with the optoloop.

Optsheaters

ChillerTemp (C)

T beforeopto

T opto (D/B)

1 OFF -23.4 -7.9 11/13

2 OFF -18 -4.3 13.1 /14.6

3 OFF -13 -0.6 15/17

4 OFF -8 3 17.5/18.9

5 OFF -3 5.3 19.1/20.4

6 OFF 5 9.5 21.7/23.0

7 OFF 13 14.4 24.9/26.5

8 OFF 20 19.2 28.6/ 29.2

9 OFF 25 22.2 30.2/31.3

Page 6: Optoboards dependence on Temperature

Day2: cold tests

L2_B27_S1_C6T opto

Page 7: Optoboards dependence on Temperature

Results

• Decrease of EFR well visible both for low and high temperature as expected. However:• Max reachable temperature is not as high enough to study

the upper limit of the working range due to the software interlock.

• At the min testable temperature with the test setup, only three boards have serious problems, having few ch. each that misbehave. BAD boards

L2_B99_S2_A7, Topto= 8.2CL2_B99_S2_C6, Topto= 13.2CL2_B27_S1_C7, Topto= 9.4C

Optoboards temperatures for the Coldest, SR1 default and warmest set points

Page 8: Optoboards dependence on Temperature

Summary range

PP0 Type Coldest Min Good Default Warmest Operative range

(warmest-min)

L0_B12_S1_A6 D 13.1 13.1 25.4 29.6 16.5

L0_B12_S1_C7 B 11.4 11.4 28 31.9 20.5

L0_B12_S2_A7 B 11.2 11.2 28 31.7 20.5

L0_B12_S2_C6 B 13.5 13.5 28.1 32.4 18.9

L2_B27_S1_A6 D 12.8 12.8 26.8 31.2 18.4

L2_B27_S1_C7 D 9.4 13.4 26.2 29.9 16.5

L2_B27_S2_A7 D 9.7 9.7 26.5 30.2 20.5L2_B27_S2_C6 D 14.4 14.4 27.3 31.4 17L2_B99_S1_A6 D 12.8 12.8 26 30.7 17.9

L2_B99_S1_C7 D 7.1 7.1 23.8 27.8 20.7

L2_B99_S2_A7 D 8.3 12.3 24.8 28.8 16.5L2_B99_S2_C6 D 13.5 19.5 26.7 31.7 12.2D1A_B01_S1 D 9.6 9.6 25.3 28.9 19.3D1A_B01_S2 D 9.6 9.6 25.9 29.8 20.2

Page 9: Optoboards dependence on Temperature

L2_B27_S2_C6: GOOD!

S17684 S17638 S17646

coldest Sr1 default warmest

15 steps in Viset for each scan (650-1000mV)

Page 10: Optoboards dependence on Temperature

L2_B27_S1_C7: BAD

S17684 S17638 S17646

coldest Sr1 default warmest

15 steps in Viset for each scan (650-1000mV)

Page 11: Optoboards dependence on Temperature

L2_B99_S2_A7: BAD

S17684 S17638 S17646

coldest Sr1 default warmest

15 steps in Viset for each scan (650-1000mV)

Page 12: Optoboards dependence on Temperature

L2_B99_S2_C6: BAD

S17684 S17638 S17646

coldest Sr1 default warmest

Bad but only two modules enabled at all temperatures

Page 13: Optoboards dependence on Temperature

The strange case of L2_B99_S2_C6_M6C

I/O Scan/Analysis

RX Current (mA) 3D_BOC Scan / comment T Opto

S17686/5817 0.04 S17684 - ok 13.3

S17687/5824 0.03 S17689 - not working 15.2

S17691/5828 0.38 S17693 - ok 17.4

S17695/5832 0.04 S17697 - Not working 19.2

S17699/5836 0.02 S17701 - Not working 20.6

S17703/5840 0.07 S17705 - Not working 22.7

S17707/5844 0.04 S17709 - Not working 24.9

S17711/5848 0.57 S17713 - ok 28.3

S17715/5856 0.02 S17717 - ok for the uppermost two Viset steps 30.7

Page 14: Optoboards dependence on Temperature

Conclusions

Optoboards behaviour vs temperature has been studied in SR1:• Automatic analysis tools are in preparation to systematically analyze data.

• Inlink/oulink scan analysis is producing a first feedback of power vs temperature (Ron, Shih-Chieh, David)

• Maybe interesting to repeat the scans vs Viset (multiple scans varying Viset setting or a 2D in/outlink scan with outer loop on Viset), at constant temperature.

• 2D scan EFR analysis on-going (Su Yung, Tobias)

• It might be worth to further extend the temperature range at lower temperatures to check when the ‘good’ optoboards start misbehaving. Switch off part of the optoboards when at the lowest chiller temperature?

• L2_B99_S2_C6_M6C: power is not always null. To be checked with the powermeter on the BOC side: -> it is worth to measure the behaviour of the bad opto channels in the pit vs optoboard temperature to know more! (Bad opto channels: 2 no opto pin current, 1 no command received , 4 dark channels)

• It will be interesting to repeat the test on the full detector when the cooling will be back and then a full characterization of our detector optoboards will be available on a wider temperature range.

• Anyway this test is interesting to have some partial results for the opto note and to prepare tools for the full scale test.

Page 15: Optoboards dependence on Temperature

Spares

• Cold, default, warm scans for all PP0s…

Page 16: Optoboards dependence on Temperature

L0_B12_S1_A6_Link0

S17684 S17638 S17646

coldest Sr1 default warmest

Page 17: Optoboards dependence on Temperature

L0_B12_S1_C7_Link0

S17684 S17638 S17646

coldest Sr1 default warmest

Page 18: Optoboards dependence on Temperature

L0_B12_S1_C7_Link1

S17684 S17638 S17646

coldest Sr1 default warmest

Page 19: Optoboards dependence on Temperature

L0_B12_S2_A7_Link0

S17684 S17638 S17646

coldest Sr1 default warmest

Page 20: Optoboards dependence on Temperature

L0_B12_S2_A7_Link1

S17684 S17638 S17646

coldest Sr1 default warmest

Page 21: Optoboards dependence on Temperature

L0_B12_S2_C6_Link0

S17684 S17638 S17646

coldest Sr1 default warmest

Page 22: Optoboards dependence on Temperature

L0_B12_S2_C6_Link1

S17684 S17638 S17646

coldest Sr1 default warmest

Page 23: Optoboards dependence on Temperature

L2_B27_S1_A6

S17684 S17638 S17646

coldest Sr1 default warmest

Page 24: Optoboards dependence on Temperature

L2_B27_S2_A7

S17684 S17638 S17646

coldest Sr1 default warmest

Page 25: Optoboards dependence on Temperature

L2_B99_S1_A6

S17684 S17638 S17646

coldest Sr1 default warmest

Page 26: Optoboards dependence on Temperature

L2_B99_S1_C7

S17684 S17638 S17646

coldest Sr1 default warmest

Page 27: Optoboards dependence on Temperature

D1A_B05_S1

S17684 S17638 S17646

coldest Sr1 default warmest

Page 28: Optoboards dependence on Temperature

D1A_B05_S2

S17684 S17638 S17646

coldest Sr1 default warmest