Option modules Altivar - Lexium S1A4559109

8
1/8 S1A45591-09 03/2020 Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this product. © 2019 Schneider Electric. All Rights Reserved. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH • Only appropriately trained persons who are familiar with and understand the contents of this manual and all other pertinent product documentation and who have received safety training to recognize and avoid hazards involved are authorized to work on and with this drive system. Installation, adjustment, repair, and maintenance must be performed by qualified personnel. • The system integrator is responsible for compliance with all local and national electrical code requirements as well as all other applicable regulations with respect to grounding of all equipment. • Many components of the product, including the printed circuit boards, operate with mains voltage. Do not touch. Use only electrically insulated tools. • Do not touch unshielded components or terminals with voltage present. • Motors can generate voltage when the shaft is rotated. Prior to performing any type of work on the drive system, block the motor shaft to prevent rotation. • AC voltage can couple voltage to unused conductors in the motor cable. Insulate both ends of unused conductors of the motor cable. • Do not short across the DC bus terminals or the DC bus capacitors or the braking resistor terminals. • Before performing work on the drive system: - Disconnect all power, including external control power that may be present. - Place a "Do Not Turn On" label on all power switches. - Lock all power switches in the open position. - Wait 15 minutes to allow the DC bus capacitors to discharge. The DC bus LED is not an indicator of the absence of DC bus voltage that can exceed 800 Vdc. - Measure the voltage on the DC bus between the DC bus terminals (PA/+ and PC/-) using a properly rated voltmeter to verify that the voltage is <42 Vdc. - If the DC bus capacitors do not discharge properly, contact your local Schneider Electric representative. Do not repair or operate the product. • Install and close all covers before applying voltage. Failure to follow these instructions will result in death or serious injury. Option modules Altivar - Lexium S1A4559109 VW3A3601 / VW3A3608 VW3A3616 / VW3A3627 VW3A3619 VW3A3609 VW3A3628 VW3A3725 VW3M3301 VW3A3720 VW3A3721 VW3M3308 VW3A3530D VW3A3607 VW3A3618

Transcript of Option modules Altivar - Lexium S1A4559109

Page 1: Option modules Altivar - Lexium S1A4559109

1/8S1A45591-0903/2020

Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibilityis assumed by Schneider Electric for any consequences arising out of the use of this product.© 2019 Schneider Electric. All Rights Reserved.

DANGERHAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH• Only appropriately trained persons who are familiar with and understand the contents of this manual and all other pertinent product documentation and who have received safety training to recognize and avoid hazards involved are authorized to work on and with this drive system. Installation, adjustment, repair, and maintenance must be performed by qualified personnel.• The system integrator is responsible for compliance with all local and national electrical code requirements as well as all other applicable regulations with respect to grounding of all equipment.• Many components of the product, including the printed circuit boards, operate with mains voltage. Do not touch. Use only electrically insulated tools.• Do not touch unshielded components or terminals with voltage present.• Motors can generate voltage when the shaft is rotated. Prior to performing any type of work on the drive system, block the motor shaft to prevent rotation.• AC voltage can couple voltage to unused conductors in the motor cable. Insulate both ends of unused conductors of the motor cable.• Do not short across the DC bus terminals or the DC bus capacitors or the braking resistor terminals.• Before performing work on the drive system:

- Disconnect all power, including external control power that may be present.- Place a "Do Not Turn On" label on all power switches.- Lock all power switches in the open position.- Wait 15 minutes to allow the DC bus capacitors to discharge. The DC bus LED is not an indicator of the absence of DC bus voltage that can exceed 800 Vdc.- Measure the voltage on the DC bus between the DC bus terminals (PA/+ and PC/-) using a properly rated voltmeter to verify that the voltage is <42 Vdc.- If the DC bus capacitors do not discharge properly, contact your local Schneider Electric representative. Do not repair or operate the product.

• Install and close all covers before applying voltage.Failure to follow these instructions will result in death or serious injury.

Option modules Altivar - LexiumS1A4559109

VW3A3601 / VW3A3608VW3A3616 / VW3A3627

VW3A3619

VW3A3609VW3A3628VW3A3725VW3M3301

VW3A3720VW3A3721VW3M3308

VW3A3530D

VW3A3607VW3A3618

Page 2: Option modules Altivar - Lexium S1A4559109

www.schneider-electric.com2/8S1A45591-09

Lexium MV DriveATV32 ATV320 ATV340 ATV600 (1) ATV900 LXM32 ATV6000

VW3A3601 EtherCAT V1.2IE03(V1.1IE08)

V2.7IE23(V1.9IE09)

V1.1IE02(V1.11IE01)

V1.2IE02(V1.8IE05) ✔

VW3A3607 PROFIBUS DP V1.1IE01(V1.5IE01)

V2.7IE23(V1.12IE01)

V1.1IE02(V1.12IE01)

V1.1IE01(V1.9IE01)

V1.1IE01(V1.10IE01) ✔

VW3A3609 DeviceNet V1.1IE01(V1.1IE01)

V2.7IE23(V1.8IE01)

V1.1IE02(V1.8IE01)

V1.1IE01(V1.5IE05)

V1.1IE01(V1.5IE05) ✔

VW3A3616 Ethernet TCP/IP V1.1IE01(V1.2IE01)

V2.7IE23(V1.EIE01)

VW3A3619 POWERLINK V1.5IE08(V1.0IE08)

V2.7IE23(V1.0IE08)

VW3A3627 PROFINET V1.8IE11(V1.0IE15)

V2.7IE23(V1.6IE01)

V1.1IE02(V1.6IE01)

V1.1IE01(V1.3IE01)

V1.1IE01(V1.3IE01) ✔

VW3A3720 Ethernet IP / Modbus TCP V1.5IE11(2)(V1.8IE12)

VW3A3721 Ethernet IP / Modbus TCP+ MultiDrive Link

V1.6IE12(2) (V1.8IE13)

VW3A3725 BACnet MS/TP V1.7IE16(V1.1IEXX)

VW3M3301 DeviceNet

VW3M3308 PROFINET

VW3A3530D ATV dPAC Module

Drive version ≥(Module version ≥ )

VW3A3608VW3A3618VW3A3628

CANopen V1.2IE03(V1.1IE01)

V2.7IE23(V1.1IE01)

V1.1IE02(V1.1IE01) ✔

Altivar Machine Altivar Process

V1.1IE01(V1.1IE01)

V1.0IE03(✔)

V1.1IE01(V1.1IE01)

V2.2IE24(V1.1IE04)

V1.8IE14(V1.1IE04)

V1.5IE10(V1.1IE04)

Upcoming commercialization,for the Altivar Firmware Version, contact your Schneider Electric Customer Care

Center on www.se.com/CCC

(1) ATV610 is compatible only with VW3A3607 PROFIBUS DP fieldbus module.(2) Drive version ≥ V2.2IE24 is only compatible with module version ≥ V1.15IE18.

V1.4IE06(V1.1IE08)

V1.0IE03(V1.3IE01)

V1.0IE03(V1.1IE31)

V1.24IE03(V1.0IE11)

≥V1.0IE03≤V1.20IE05

(V1.0)

Option Module

Page 3: Option modules Altivar - Lexium S1A4559109

S1A45591-09 3/8 www.schneider-electric.com

ATV32Mounting

ATV320

4)

XXXXXX

XX

3)

1)

2)

5)

XXXXXXXXXXXXXXXX

!

XXXXXX

XX

!

Page 4: Option modules Altivar - Lexium S1A4559109

www.schneider-electric.com4/8

ATV32Removing

ATV320

S1A45591-09

1) 2)

Page 5: Option modules Altivar - Lexium S1A4559109

www.schneider-electric.com5/8

ATV320Mounting

Removing

S1A45591-09

CLIC

!

NVE22661

VW3A3600

Page 6: Option modules Altivar - Lexium S1A4559109

S1A45591-09 6/8 www.schneider-electric.com

Removing

LXM32M

MountingATV340

1 2 3

1

2

4

3

!

CLIC

Slot 1

Slot 2

Slot 3

Page 7: Option modules Altivar - Lexium S1A4559109

S1A45591-09 7/8 www.schneider-electric.com

ATV340, ATV600, ATV900STATUS

ETH LNK

ETH NS

ASF

COM

-----

-----

MNS

-----

VW3A36

09

LNK1

LNK2

BF

SF

VW3A36

27

RUN

-----

BF

VW3A36

07

RUN

-----

ERR

-----

VW3A36

18

VW3A36

08

VW3A36

28

1)

Mounting

ATV600

ATV340, ATV900

!2)

E

LNK2

LNK1MS

NS

VW3A37

20

VW3A37

21

3)

AB

4)

STATUS

ASF!

COM

LNK1

MS

NS

LNK2

5)

VW3A36

28

VW3A36

18

VW3A36

08

RUN

ERR

VW3A36

27

SF

BF

VW3A36

01

ERR

RUNECT

VW3A36

07

BF

-----

VW3A36

09

MNS

-----

MS

RX

TX

-----

VW3A37

25

L / A1S/E

L / A2

VW3A36

19

LNK1RUN/ERR

NSLNK2

VW3A

3530

D

ES/E

VW3A36

19

NSRUN/ERR

VW3A35

30D

Page 8: Option modules Altivar - Lexium S1A4559109

8/8S1A45591-09 www.schneider-electric.com

1)

2)

ATV340, ATV600, ATV900 Removing