Optical fibre cables and optoelectronic converters - Policie

32
Optical fibre cables and optoelectronic converters

Transcript of Optical fibre cables and optoelectronic converters - Policie

Page 1: Optical fibre cables and optoelectronic converters - Policie

Optical fibre cables and optoelectronic converters

Page 2: Optical fibre cables and optoelectronic converters - Policie

INTRODUCTION

From 1988 Optral design, manufacture and commercialize optical cables as well optoelectronic equipments for audio, video and data signals.

Our philosophy is to supply the best cable for each application, within the shortest possible delivery time and with no minimum length limit.

We are specialized in design and manufacture of cables according to the strict needs of our customers.

We are proud to be the manufacturer with the best service in Europe, replying to any demand of our customers quickly, giving the shorter delivery times and delivering to the expected date.

We strive to keep our customers’ satisfaction, more of them being customers from Optral foundation date.

Page 3: Optical fibre cables and optoelectronic converters - Policie

p.3p.3

IndexTIGHT BUFFER CABLESCPS 04FLAT 04ZIPCORD / MINI ZIPCORD 05CDAS 05CDI 06CDIR 06CDG 07CDAD - CDAD UL 07CDAD: The authentic universal fibre optic cable 08-09CDAD over the 16 F.O. 10CDIR-AD 10CDIR-AM 11CDAM 11

LOOSE TUBE CABLESNEXO (DT) 12NEXO (DP) 12DP 13TENAX DP 13PKP 14DPDP 14DPMP-1 15DPMP 15DSP-1 16DSP 16DPSP-1 17DPSP 17ADSS 80 / 120 / 150 / 200 18ADSS-50 U 19CAM FIG8 19

OPTRAL SOLUTIONS FTTx LINECAS-S1 20CAS FLAT-F1 20CAR / R1 21CDV / V1 21CAR - R2 22ADSS FLAT - F2 22ABD - 01 23ABD 23SUBSCRIBER CONNECTION POINT SCP 24KIT FTTx LINE 24CABLE BOX 25 SOLUTION FTTx 26

OPTICAL FIBRESMULTIMODE OPTICAL FIBRE 62,5 / 125 28MULTIMODE OPTICAL FIBRE50 / 125 28SINGLEMODE OPTICAL FIBRE SMF G.652D / G.655 29SINGLEMODE OPTICAL FIBRE - G.657 29

OPTOELECTRONICVM1 - VIDEO 30OTHER EQUIPMENTS 30DM5 - SERIE RS232, RS422 AND RS485 31

Patchcord

Metallic ArmouredIndoorIndoor

Indoor / OutdoorIndoor / Outdoor

Indoor / OutdoorDielectric Outdoor

Metallic OutdoorMetallic Outdoor

Indoor / OutdoorIndoor / OutdoorIndoor / OutdoorIndoor / Outdoor

Dielectric OutdoorDielectric Outdoor

Metallic Outdoor

Self-supported

Optical Fibres

Accessories

FTTx

Optoelectronic

Page 4: Optical fibre cables and optoelectronic converters - Policie

p.4

Tight buffer cables

Tight buffer cables

CPS

Pat

chco

rd

01. TIGHT BUFFER FIBRE02. ARAMID03. OUTER JACKET

Cable description•TightBufferFibre(0.9mm)•Aramid•OuterJacket

Fire resistance•Flameretardant•Lowsmokeemission

Applications•Indoor•Pigtailandjumperconnections•Directconnectiontoterminal equipments•BasedonDINVDE0888Part4

Options•Jackets:LSZH•Easy-StripBuffer•SpecialColoursCode

Advantages•Flexible/Resilient/Totallydielectric/ Direct connectorization.

SPECIFICATIONS

Fibres 1

Strength members Aramid Yarns

Outer jacket Thermoplastic FRLS1

Identification Orange (MM62) / Blue (MM50) / Yellow (SM)2

Weight (Kg/Km) 7.5

Outer ø (mm) 2.9 ±0.1

Tensile Load Perm / Inst (N) 200 / 350

Crush (N) 500

Temperature Range -5 ºC to +60 ºC

Min. Bending Radius 15 x ø Outer

Max. Length 2000 m

Flat

Pat

chco

rd

01. TIGHT BUFFER FIBRE02. ARAMID03. INNER JACKET04. OUTER JACKET

SPECIFICATIONS

Fibres 2

Strength members Aramid Yarns

Outer jacket FRLS1

ø Subcables diameter (mm) 2.9 ±0.1

Outer jacket Thermoplastic FRLS1

Colour Orange (MM62) / Blue (MM50) / Yellow (SM)

Weight (Kg/Km) 27

Outer ø (mm) 3.8 x 6.7 ±0.2

Tensile Load Perm / Inst (N) 400 / 700

Crush (N) 750

Temperature Range -5 ºC to +60 ºC

Min. Bending Radius 15 x ø Outer

Max. Length 2000 m

SPECIFICATIONS

Zipcord Mini ZIP-16 Mini ZIP-21 Mini ZIP-25

Fibres 2

Identification Colours

Strength members Aramid Yarns

Outer jacketThermoplastic

FRLS1 LSZH

Colour Orange (MM62) / Blue (MM50) / Yellow (SM)2

Weight (Kg/Km) 15 5.5 9 12.2

ø Outer (mm) 2.8 x 5.9 ±0.1 1.6 x 3.4 ±0.1 2.1 x 4.4 ±0.1 2.5 x 5.3 ±0.1

Tensile Load Perm / Inst (N) 400 / 700 80 / 130 240 / 400 300 / 500

Crush (N) 500 300 300 500

Temperature Range -5 ºC to +60 ºC

Min. Bending Radius 15 x ø Outer

Max. Length 2000 m

SPECIFICATIONS

Fibres 2 4 6 8 10 12

Strength Members Aramid Yarns

Inner jacket Thermoplastic

Armour Corrugated Steel Armour

Outer jacket Thermoplastic LSZH1

Colour Dark Grey

Weight (Kg/Km) 109 175

ø Outer (mm) 9.6 ±0.3 12.1 ±0.3

Tensile Load Perm / Inst (N) 1200 / 2150

Crush (N) 1500

Temperature Range -20 ºC to +70 ºC

Min. Bending Radius 20 x ø Outer

Maximum Length 4200 m

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794Fire test according to: UNE-EN 50265 (IEC 60332-1) / UNE-EN 50268 (IEC 61034-1/2).

1 FRLS – Special PVC heavy metals free, low halogen and low smoke emission and flame retardant.2ForsinglemodefibreG.657thejacketcolourisivory.

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794Fire test according to: UNE-EN 50265 (IEC 60332-1) / UNE-EN 50268 (IEC 61034-1/2).Innerjacketcolour:red,green.1 FRLS – Special PVC heavy metals free, low halogen and low smoke emission and flame retardant.2 ForsinglemodefibreG.657thejacketcolourisivory.

Cable description•TightBufferFibre(0.9mm)•Aramid•InnerJacket•OuterJacket

Fire resistance•Flameretardant•Lowsmokeemission

Applications•Indoor•Directconnectiontoterminal equipments•BasedonDINVDE0888Part4

Options•Jackets:LSZH•Easy-StripBuffer•SpecialColoursCode

Advantages•Flexible/Resilient/Totallydielectric/ Direct connectorization.

FLAMERETARDANT

LOW SMOKEEMISSION

HIGHFLEXIBILITY

MOISTUREPROTECTED

TOTALLYDIELECTRIC

Page 5: Optical fibre cables and optoelectronic converters - Policie

p.5

Tight buffer cables

Tight buffer cables

SPECIFICATIONS

Fibres 1

Strength members Aramid Yarns

Outer jacket Thermoplastic FRLS1

Identification Orange (MM62) / Blue (MM50) / Yellow (SM)2

Weight (Kg/Km) 7.5

Outer ø (mm) 2.9 ±0.1

Tensile Load Perm / Inst (N) 200 / 350

Crush (N) 500

Temperature Range -5 ºC to +60 ºC

Min. Bending Radius 15 x ø Outer

Max. Length 2000 m

SPECIFICATIONS

Fibres 2

Strength members Aramid Yarns

Outer jacket FRLS1

ø Subcables diameter (mm) 2.9 ±0.1

Outer jacket Thermoplastic FRLS1

Colour Orange (MM62) / Blue (MM50) / Yellow (SM)

Weight (Kg/Km) 27

Outer ø (mm) 3.8 x 6.7 ±0.2

Tensile Load Perm / Inst (N) 400 / 700

Crush (N) 750

Temperature Range -5 ºC to +60 ºC

Min. Bending Radius 15 x ø Outer

Max. Length 2000 m

Zipcord / Mini Zipcord

Pat

chco

rd

01. TIGHT BUFFER FIBRE02. ARAMID03. OUTER JACKET

SPECIFICATIONS

Zipcord Mini ZIP-16 Mini ZIP-21 Mini ZIP-25

Fibres 2

Identification Colours

Strength members Aramid Yarns

Outer jacketThermoplastic

FRLS1 LSZH

Colour Orange (MM62) / Blue (MM50) / Yellow (SM)2

Weight (Kg/Km) 15 5.5 9 12.2

ø Outer (mm) 2.8 x 5.9 ±0.1 1.6 x 3.4 ±0.1 2.1 x 4.4 ±0.1 2.5 x 5.3 ±0.1

Tensile Load Perm / Inst (N) 400 / 700 80 / 130 240 / 400 300 / 500

Crush (N) 500 300 300 500

Temperature Range -5 ºC to +60 ºC

Min. Bending Radius 15 x ø Outer

Max. Length 2000 m03 01

02

CDASM

etal

lic A

rmou

redDescripción cable

•Tight Buffer Fibre (0.9 mm)•Aramid•Inner Jacket.•Metallic Armour •Outer Jacket

Fire resistance•Flame retardant•Halogen free•Low smoke emission

Applications•Universal (Indoor / Outdoor)

Rodent protection•Excellent rodent resistance

Options•Jackets: PE•Special colour code

Advantages•Compact / Lightweight / Tough / Resistant / Easy to strip (gel free) / Reduced diameter / Direct connectorization / Saves installation costs / Excellent rodent protection.

SPECIFICATIONS

Fibres 2 4 6 8 10 12

Strength Members Aramid Yarns

Inner jacket Thermoplastic

Armour Corrugated Steel Armour

Outer jacket Thermoplastic LSZH1

Colour Dark Grey

Weight (Kg/Km) 109 175

ø Outer (mm) 9.6 ±0.3 12.1 ±0.3

Tensile Load Perm / Inst (N) 1200 / 2150

Crush (N) 1500

Temperature Range -20 ºC to +70 ºC

Min. Bending Radius 20 x ø Outer

Maximum Length 4200 m

01. TIGHT BUFFER FIBRE02. ARAMID03. INNER JACKET.04. METALLIC ARMOUR 05. OUTER JACKET

05

01

04 03

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794Fire test according to: UNE-EN 50265 (IEC 60332-1) / UNE-EN 50268 (IEC 61034-1/2).

1 FRLS – Special PVC heavy metals free, low halogen and low smoke emission and flame retardant.2ForsinglemodefibreG.657thejacketcolourisivory.

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794Fire test according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267 (IEC 60754-1) / UNE-EN 50268 (IEC 61034-1/2).Fibres colour code: red, green.1 LSZH - Halogen free, low smoke and flame retardant thermoplastic compound.2ForsinglemodefibreG.657thejacketcolourisivory.

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794Fire test according to: UNE-EN 50265 (IEC 60332-1) / UNE-EN 50268 (IEC 61034-1/2).Innerjacketcolour:red,green.1 FRLS – Special PVC heavy metals free, low halogen and low smoke emission and flame retardant.2 ForsinglemodefibreG.657thejacketcolourisivory.

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794.Fire test according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267 (IEC 60754-1) / UNE-EN 50268 (IEC 61034-1/2).Fibres colour code: red, green, grey, yellow, blue, natural, white, brown, violet, orange, pink, black.1LSZH – Halogen free, low smoke emissions and flame retardant thermoplastic compound.

Cable description•TightBufferFibre(0.9mm)•Aramid•OuterJacket

Fire resistance•Flameretardant•Lowsmokeemission

Applications•Indoor•Pigtailandjumperconnections•Directconnectiontoterminal equipments•BasedonDINVDE0888Part4

Options•Jackets:LSZH•Easy-StripBuffer•SpecialColoursCode

Advantages•Flexible/Resilient/Totallydielectric/ Direct connectorization.

(Only MINI ZIPCORD)

Page 6: Optical fibre cables and optoelectronic converters - Policie

p.6

Tight buffer cables

Tight buffer cables

Cdi

Indo

or

01. TIGHT BUFFER FIBRE02. ARAMID03. OUTER JACKET

Cable Description•TightBufferFibre(0.9mm)•Aramid•OuterJacket

Fire Resistance•Flameretardant•Halogenfree•Lowsmokeemission

Applications•Indoor•BasedonDINVDE0888part6.

Options•Jackets:PVC/PU•Specialcolourcode

Advantages•Compact/Lightweight/Flexible / Easy to strip (gel free) / Totally dielectric /Reduced diameter / Direct connectorization / Saves installation costs.

SPECIFICATIONS

Fibres 2 4 6 8 12

Strength Members Aramid Yarns

Outer jacket Thermoplastic LSZH1

Colour Orange (MM62) / Blue (MM50) / Yellow (SM)

Weight (Kg/Km) 19 22 29 37 49

ø Outer (mm) 4.5 ±0.3 4.9 ±0.3 5.6 ±0.3 6.3 ±0.3 7.3 ±0.3

Tensile Load Perm / Inst (N) 400 / 700 500 / 850 600 / 1000

Crush (N) 1000

Temperature Range -5 ºC to +60 ºC

Min. Bending Radius 20 x ø Outer

Maximum Length 4200 m

Cdir

Indo

or

01. TIGHT BUFFER FIBRE02. ARAMID03. INDIVIDUAL JACKET04. OUTER JACKET

Cable Description•TightBufferFibre(0.9mm)•Aramid•IndividualJacket(ø 2.5 mm)•OuterJacket

Fire resistance•Flameretardant•Halogenfree•Lowsmokeemission

Applications•Indoor•Directconnectiontoterminal equipments•BasedonDINVDE0888part6

Options•Jackets:PVC/LSZH/PE/PU/PA•Specialcolourcode

Advantages•Compact/Resilient/Tough/Excellent mechanical resistance / Easy to strip (gel free) / Totally dielectric / Direct connectorization.

SPECIFICATIONS

Fibres 2 4 6 8 12 16

Subcables strength members Aramid Yarns

ø Subcables (mm) 2.5

Subcables jacket Thermoplastic LSZH1

Identification Numbers

Outer jacket Thermoplastic LSZH1

Colour Orange (MM62) / Blue (MM50) / Yellow (SM)

Weight (Kg/Km) 54 54 77 96 130 173

ø Outer (mm) 7.9 ±0.3 7.9 ±0.3 9.6 ±0.3 11.1 ± 0.5 12.1 ± 0.5 13.9 ± 0.5

Tensile Load Perm / Inst (N) 600/1000 800/1350 1200/2050 1600/2700 2400/3500 3200/3500

Crush (N) 2000

Temperature Range -20 ºC to +70 ºC

Min. Bending Radius 20 x ø Outer

Max. Length 3200 m

SPECIFICATIONS

Fibre count 2 4 6 8 12

Armour Reinforced fibreglass yarns WB

Outer jacket Thermoplastic LSZH1

Colour Black

Weight (Kg/Km) 34 37 42 57 69

ø Outer (mm) 6.0 ±0.3 6.3 ±0.3 6.5 ±0.3 7.5 ± 0.3 8.3 ± 0.3

Tensile Load Perm / Inst (N) 650/1100 650/1100 650/1100 850/1450 850/1450

Crush (N/100mm) 1300

Temperature range -20 ºC to +70 ºC

Min. Bending radius 20 x ø Outer

Maximum Length 4200 m

SPECIFICATIONS

Fibres 2 4 6 8 12

Strength members Reinforced Fiberglass Yarns (WB)

Inner jacket Thermoplastic

Armour Fibreglass Braid

Outer jacket Thermoplastic LSZH1

Colour Black

Weight (Kg/Km) 89 93 98 123 141

ø Outer (mm) 9.0 ±0.3 9.3 ±0.3 9.5 ±0.3 10.7 ±0.3 11.5 ±0.3

Tensile Load Perm / Inst (N) 600 / 1100 700 / 1250 800 / 1800

Crush (N) 1500

Temperature Range -20 ºC to +70 ºC

Min. Bending Radius 20 x ø Outer

Maximum Length 4200 m

StandardsEnvironmental and mechanical tests according to: EN 187000 and CEI 60794.Fire test according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267 (IEC 60754-1) / UNE-EN 50268 (IEC 61034-1/2).

Fibres colour code: red, green, grey, yellow, blue, natural, white, brown, violet, orange, pink, black.

1LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.

StandardsEnvironmental and mechanical tests according to: EN 187000 and CEI 60794.Fire test according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267(IEC 60754-1)/UNE-EN 50268(IEC 61034-1/2).1 LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.

Page 7: Optical fibre cables and optoelectronic converters - Policie

p.7

Tight buffer cables

Tight buffer cables

SPECIFICATIONS

Fibres 2 4 6 8 12

Strength Members Aramid Yarns

Outer jacket Thermoplastic LSZH1

Colour Orange (MM62) / Blue (MM50) / Yellow (SM)

Weight (Kg/Km) 19 22 29 37 49

ø Outer (mm) 4.5 ±0.3 4.9 ±0.3 5.6 ±0.3 6.3 ±0.3 7.3 ±0.3

Tensile Load Perm / Inst (N) 400 / 700 500 / 850 600 / 1000

Crush (N) 1000

Temperature Range -5 ºC to +60 ºC

Min. Bending Radius 20 x ø Outer

Maximum Length 4200 m

SPECIFICATIONS

Fibres 2 4 6 8 12 16

Subcables strength members Aramid Yarns

ø Subcables (mm) 2.5

Subcables jacket Thermoplastic LSZH1

Identification Numbers

Outer jacket Thermoplastic LSZH1

Colour Orange (MM62) / Blue (MM50) / Yellow (SM)

Weight (Kg/Km) 54 54 77 96 130 173

ø Outer (mm) 7.9 ±0.3 7.9 ±0.3 9.6 ±0.3 11.1 ± 0.5 12.1 ± 0.5 13.9 ± 0.5

Tensile Load Perm / Inst (N) 600/1000 800/1350 1200/2050 1600/2700 2400/3500 3200/3500

Crush (N) 2000

Temperature Range -20 ºC to +70 ºC

Min. Bending Radius 20 x ø Outer

Max. Length 3200 m

CDG

Indo

or /

Out

door

01. TIGHT BUFFER FIBRE (0,9 mm) 02. FIBERGLASS REINFORCEMENTS-WB03. OUTER JACKET

Cable Description•Tight Buffer Fibre (0.9 mm)•Fiberglass Reinforcements-WB•Outer Jacket

Fire resistance•Flame retardant•Halogen free•Low smoke emission

Applications•Universal (Indoor / Outdoor)

Rodent Protection•Rodent Protected

Options•Outerjacket:PVC/PU•Special colour code

Advantages•Compact / Lightweight / Flexible Easy to strip ( gel free ) / Totally dielectric Reduced diameter / Direct connectorization / Saves installation costs / Rodent protected.

StandardsEnvironmental and mechanical tests according to EN 187000 and IEC 60794.Fire tests according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267-2-1/-2 (IEC 60754-2-1/-2) / UNE-EN 61034-2 (IEC 61034-2).Fibre standard colour coding: red – green – grey – yellow – blue – natural – white – brown – violet – orange – pink – black.1 LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.

SPECIFICATIONS

Fibre count 2 4 6 8 12

Armour Reinforced fibreglass yarns WB

Outer jacket Thermoplastic LSZH1

Colour Black

Weight (Kg/Km) 34 37 42 57 69

ø Outer (mm) 6.0 ±0.3 6.3 ±0.3 6.5 ±0.3 7.5 ± 0.3 8.3 ± 0.3

Tensile Load Perm / Inst (N) 650/1100 650/1100 650/1100 850/1450 850/1450

Crush (N/100mm) 1300

Temperature range -20 ºC to +70 ºC

Min. Bending radius 20 x ø Outer

Maximum Length 4200 m

Cdad - Cdad UL(Optional)In

teri

or /

Out

door

Cable Description•Tight Buffer Fibre (0.9 mm)•Reinforced Fiberglass Yarns•Inner Jacket•Dielectric Armour•Outer Jacket

Fire resistance•Flame retardant•Halogen free•Low smoke emission•Fire resistant (180 min)

Applications•Universal (Indoor / Outdoor)

Rodent Protection•Rodent resistant

Options•Jackets: PVC / PU / PA•Special colour code

Advantages•Compact / Lightweight / Flexible / Tough / Resistant / Easy to strip (gel free) /Totally dielectric / Reduced diameter / Direct connectorization / Saves installation costs / Rodents protected.

SPECIFICATIONS

Fibres 2 4 6 8 12

Strength members Reinforced Fiberglass Yarns (WB)

Inner jacket Thermoplastic

Armour Fibreglass Braid

Outer jacket Thermoplastic LSZH1

Colour Black

Weight (Kg/Km) 89 93 98 123 141

ø Outer (mm) 9.0 ±0.3 9.3 ±0.3 9.5 ±0.3 10.7 ±0.3 11.5 ±0.3

Tensile Load Perm / Inst (N) 600 / 1100 700 / 1250 800 / 1800

Crush (N) 1500

Temperature Range -20 ºC to +70 ºC

Min. Bending Radius 20 x ø Outer

Maximum Length 4200 m

01 TIGHT BUFFER FIBRE02 REINFORCED FIBERGLASS YARNS03 INNER JACKET04 DIELECTRIC ARMOUR05 OUTER JACKET

03

02

01

05

04

StandardsEnvironmental and mechanical tests according to: EN 187000 and CEI 60794.Fire test according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267 (IEC 60754-1) / UNE-EN 50268 (IEC 61034-1/2).

Fibres colour code: red, green, grey, yellow, blue, natural, white, brown, violet, orange, pink, black.

1LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.

StandardsEnvironmental and mechanical tests according to: EN 187000 and CEI 60794.Fire test according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267(IEC 60754-1)/UNE-EN 50268(IEC 61034-1/2).1 LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794.Fire test according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267 (IEC 60754-1) / UNE-EN 50268 (IEC 61034-1/2).Fibres colour code: red, green, grey, yellow, blue, natural, white, brown, violet, orange, pink, black.1 LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.

Page 8: Optical fibre cables and optoelectronic converters - Policie

CDADThe authentic universal fibre optic cable

p.8

Technical description

THE CABLE

Dielectric armoured distribution cable: CDAD very strong, totally dielectric and rodent-protected. Can be used in indoor and outdoor.

Construction

1. Optical fibre 2. Tight buffer 3. Aramid strength members 4.Innerjacket 5.FibreglassbraidarmourLSZHouterjacket

Advantages

•Verystrongandresistantconstruction •Directtermination •Flexibleandreliable •Veryeasytostrip(gelfree) •Flameretardant(Fe180),lowsmokeemissionandhalogenfree(LSZH) •Totallydielectric •Rodentsprotection

1

2

3

4

5

6

Fibres types

Fibr

e S

M:

Fibr

e M

M:

Standard jackets

The CDAD cable, as well as all OPTRAL’s cables, can be manufactured with any optical fibres existing on the market. This chart intends to help you to make your choice:

Fibre type Denomination Application

SM-9/125S/UIT G-652 SM Standard dispersion (optimized 1300nm)

SM-9/125S/UIT G-653 SM Displaced dispersion (long distance applications)

SM-9/125S/UIT G-655 SM For applications DWDM

Application Fibre type Characteristics

Video vigilance MM 62,5/125 S/IEC 60793 Atenuatión: 3,2 dB/K-(850), 1,0 dB/K-(1300)

Industrial Control MM 50/125 S/IEC 60793-2 Atenuatión: 3,0 dB/K-(850), 0,9 dB/K-(1300)

Application Fibre type Distance (10 Gigabit Ethernet)

Data transmission Standard MM 62,5/125 ó 50/125 30m/80mMM 50/125 Máx. Cap. 150 (exceed 0M2) 150m

MM 50/125 Máx. Cap. 300 (0M3) 300mEstándar SM S/UIT G-652 >2000m

Fibre type Distance (10 Gigabit Ethernet)

Standard MM 62,5/125 ó 50/125 550mHiCap 62,5/125 1000mHiCap 50/125 2000m

Onejacketforeachapplication:

Polyethylene (PE): For outdoors, very resistant to moisture and UV rays.

Poliolefyne (LSZH): Zero halogen material for indoors. Flame retardant.

Polyurethane: Very flexible and resistant to chemical agents with rip resistance.

Nitrile rubber: Resistant to oils and hydrocarbons.

(Othersjacketsonrequest:TEFLON,Polyamide, PVC, etc…)

Page 9: Optical fibre cables and optoelectronic converters - Policie

p.9

Advantages

Antihumedad

Moisture is the main and ever-present enemy toopticalfibre.Bydamagesinjacketorbycondensation.ThedoublejacketofCDADandits tight construction convert it into a watertight cable.

Without axial migration

This phenomenon, usual for Loose Tube cables, does not appear in our Tight Buffered CDAD cable; making it suitable for vertical lays whatever its lengths and its environment.

DISMANTLED FIBRE

TWISTED AND COMPRESSED FIBRE

Fibre,nonjelly-protectedand under tension, bends on a very acute angle. The breaking risk is very high.

The fibre excess of all the length accumulates on few meters of the lower part, increasing the attenuation due to compression efforts and numerous and closed bends.

Rodents protection Strong and flexible

Flame resistant (Fe-180)

Thedoublejacketandthefibre-glass braid armour provide an effective rodents protection.

Just as can be observed in the accompanying photos, our CDAD cable, in spite of its excellent flexibility, commodity and simple economic installation, is, above all, extremely strong and resistant.

1 CDAD bent double and inserted between the jaws of a dynamometer.

2 Cable being crushed by a pressure of 500kgs.

3 Cable state after being removed from the dynamometer.

4 Despite the tremendous pressure exerted on the cable, the fibre remains unaltered.

Fe180 denomination guarantees that a cable maintains operating without interrupting for 3 hours at an ignition temperature of 750ºC. (Norms: DIN-VDE 0266, IEC 60331 and UNE 20431-32). Moreover, it is a low smoke emission and halogen free (LSZH) cable.

1

3

2

4

Moisture

Optical fibre

Jacket

Gel

“ThedoublejacketofCDADanditstight construction convert it into a watertight cable”

Page 10: Optical fibre cables and optoelectronic converters - Policie

p.10

Tight buffer cables

Tight buffer cables

Cdad over 16 Fibres

Indo

or /

Out

door

01. CENTRAL ELEMENT (GRP)02. TIGHT BUFFER FIBRE03. ARAMID04. JACKET (SUBCABLES)05. DIELECTRIC ARMOUR06. OUTER JACKET

Cable Description•CentralElement(GRP)•TightBufferFibre(0.9mm)•Aramid•Jacket(Subcables)•DielectricArmour•OuterJacket

Fire Resistance•Flameretardant•Halogenfree•Lowsmokeemission•Fireresistance(180min)

Applications•Universal(Indoor/Outdoor)

Rodent protection•Rodentresistant

Options•Jackets:PVC/PU/PA•Specialcolourcode

Advantages•Compact/Tough/Resistant/Easy to strip (gel free) / Totally dielectric / Direct connectorization / Saves installation costs / Rodent protected.

Cdir-ad

Die

lect

ric

Out

door

01. TIGHT BUFFER FIBRE02. ARAMID03. INDIVIDUAL JACKET04. INNER JACKET05. DIELECTRIC ARMOUR06. OUTER JACKET

Cable Description•TightBufferFibre(0.9mm)•Aramid•IndividualJacket(ø2.5mm)•InnerJacket•DielectricArmour•OuterJacket

Fire Resistance•Flameretardant•Halogenfree•Lowsmokeemission

Applications•Universal(Indoor/Outdoor)•Directconnectiontoterminal equipments

Rodent protection•Rodentresistant

Options•Jackets:PVC/PE/PU/PA•Specialcolourcode•BufferEasy-Strip

Advantages•Compact/Flexible/Resilient/Tough / Excellent mechanical resistant / Easy to strip (gel free) / Totally dielectric / Direct connectorization / Rodent protected.

06

01

03

0204

05

SPECIFICATIONS

Fibres 16 24 32 36 48 64 72

Strength Members Aramid Yarns

Subcables 4 FO 4 6 8 9 12 16 18

Subcables jacket Thermoplastic

Identification Numbers

Armour Fibreglass Braid

Outer jacket Thermoplastic LSZH1

Colour Dark Grey / Black

Weight (Kg/Km) 116 164 220 258 280 347 353

ø Outer (mm) 11.2 ±0.5 13.2 ±0.5 15.2 ±0.5 16.3 ±0.5 18.1 ±0.5 20.1 ±0.5 20.1 ±0.5

Tensile Load Perm/Inst (N) 800/1450 1100/2000 1400/2500 1550/2800 2200/3950 2900/4000 2900/4000

Crush (N) 1500

Temperature Range -20 ºC to +70 ºC

Min. Bending Radius 20 x ø Outer

Maximum Length 1800 m

04

02

01

03

06

05

SPECIFICATIONS

Fibres 2 4 6 8 12 16Subcables strength members Aramid Yarnsø Subcables (mm) 2.5Subcables Jacket ThermoplasticIdentification NumbersInner jacket ThermoplasticArmour Fiberglass BraidOuter jacket Thermoplastic LSZH1

Colour Orange (MM62) / Blue (MM50) / Yellow (SM)Weight (Kg/Km) 110 121 167 197 240 287

ø Outer (mm) 10.9 ± 0.5 10.9 ± 0.5 13.0 ± 0.5 14.5 ± 0.5 15.5 ± 0.5 17.1 ± 0.5

Tensile Load Perm / Inst (N) 800/1450 1000/1800 1400/2500 1800/3250 2600/4000 3000/4000Crush (N) 2000Temperature Range -20 ºC to +70 ºCMin. Bending Radius 20 x ø OuterMaximum Length 3200 m

SPECIFICATIONS

Fibres 2 4 6 8 12

Strength Members Reinforced Fiberglass Yarns (WB)

Inner jacket Thermoplastic

Armour Steel Wires Braid

Outer jacket Thermoplastic LSZH1

Colour Black

Weight (Kg/Km) 98 104 111 133 157

ø Outer (mm) 9.0 ±0.3 9.3 ±0.3 9.5 ±0.3 10.7 ±0.3 11.5 ±0.3

Tensile Load Perm / Inst (N) 700 / 1250 800 / 1450 900 / 1600

Crush (N) 1500

Temperature Range -20 ºC to +70 ºC

Min. Bending Radius 20 x ø Outer

Maximum Length 4200 m

SPECIFICATIONS

Fibres 2 4 6 8 12 16Subcables strength members Aramid Yarns

ø Subcables (mm) 2.5Subcables jacket ThermoplasticColour Orange (MM62) / Blue (MM50) / Yellow (SM)Identification NumbersInner jacket Thermoplastic LSZH1

Armour Steel Wires BraidOuter jacket Thermoplastic LSZH1

Colour Orange (MM62) / Blue (MM50) / Yellow (SM)Weight (Kg/Km) 123 135 183 218 263 372ø Outer (mm) 10.9 ±0.5 10.9 ±0.5 13.0 ±0.5 14.5 ±0.5 15.5 ±0.5 17.3 ±0.5

Tensile Load Perm / Inst (N) 900/1600 1100/2000 1500/2700 1900/3400 2700/4000 3000/4000Crush (N) 2000Temperature Range -20 ºC to +70 ºCMin. Bending Radius 20 x ø OuterMax. Length 4200 mStandards

Environmental and mechanical tests according to EN 187000 and CEI 60794.Fire test according to: UNE-EN 50266(IEC 60332-3) / UNE-EN 50267(IEC 60754-1) / UNE-EN 50268(IEC 61034-1/2)Fibres colour code: red, green, grey , yellow.1LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.

StandardsEnvironmental and mechanical tests according to: EN 187000 and CEI 60794.Fire test according to: UNE-EN 50266(IEC 60332-3) / UNE-EN 50267(IEC 60754-1) / UNE-EN 50268(IEC 61034-1/2)1 LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794.Fire test according to: UNE-EN 50266(IEC 60332-3)/UNE-EN 50267(IEC 60754-1)/UNE-EN 50268(IEC 61034-1/2).1 LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.

Page 11: Optical fibre cables and optoelectronic converters - Policie

p.11

Tight buffer cables

Tight buffer cables

SPECIFICATIONS

Fibres 16 24 32 36 48 64 72

Strength Members Aramid Yarns

Subcables 4 FO 4 6 8 9 12 16 18

Subcables jacket Thermoplastic

Identification Numbers

Armour Fibreglass Braid

Outer jacket Thermoplastic LSZH1

Colour Dark Grey / Black

Weight (Kg/Km) 116 164 220 258 280 347 353

ø Outer (mm) 11.2 ±0.5 13.2 ±0.5 15.2 ±0.5 16.3 ±0.5 18.1 ±0.5 20.1 ±0.5 20.1 ±0.5

Tensile Load Perm/Inst (N) 800/1450 1100/2000 1400/2500 1550/2800 2200/3950 2900/4000 2900/4000

Crush (N) 1500

Temperature Range -20 ºC to +70 ºC

Min. Bending Radius 20 x ø Outer

Maximum Length 1800 m

SPECIFICATIONS

Fibres 2 4 6 8 12 16Subcables strength members Aramid Yarnsø Subcables (mm) 2.5Subcables Jacket ThermoplasticIdentification NumbersInner jacket ThermoplasticArmour Fiberglass BraidOuter jacket Thermoplastic LSZH1

Colour Orange (MM62) / Blue (MM50) / Yellow (SM)Weight (Kg/Km) 110 121 167 197 240 287

ø Outer (mm) 10.9 ± 0.5 10.9 ± 0.5 13.0 ± 0.5 14.5 ± 0.5 15.5 ± 0.5 17.1 ± 0.5

Tensile Load Perm / Inst (N) 800/1450 1000/1800 1400/2500 1800/3250 2600/4000 3000/4000Crush (N) 2000Temperature Range -20 ºC to +70 ºCMin. Bending Radius 20 x ø OuterMaximum Length 3200 m

Cdir-am

Met

allic

Out

door

01. TIGHT BUFFER FIBRE02. ARAMID03. INDIVIDUAL JACKET04. INNER JACKET05. METALLIC ARMOUR06. OUTER JACKET

Cable Description•Tight Buffer Fibre (0.9 mm)•Aramid•Individual Jacket (ø 2.5 mm)•Inner Jacket•Metallic Armour•Outer Jacket

Fire Resistance•Flame retardant•Halogen free•Low smoke emission

Applications•Outdoor•Direct connection to terminal equipments

Rodent protection•Excellent rodent resistance

Options•Jackets: PVC / PE / PU / PA•Special colour code•Buffer Easy-Strip

Advantages•Compact / Flexible / Resilient / Tough / Excellent mechanical resistance / Easy to strip (gel free) / Direct connectorization / Excellent rodent protection.

CdamM

etal

lic O

utdo

or

Cable Description• Tight Buffer Fibre (0.9 mm)• Reinforced Fiberglass Yarns• Inner Jacket.• Metallic Armour• Outer Jacket

Fire Resistance• Flame retardant• Halogen free• Low smoke emission

Applications• Universal (Indoor / Outdoor)

Rodent protection• Excellent rodent resistance

Options• Jackets: PVC / PU / PA• Special colour code

Advantages• Compact / Lightweight / Flexible / Tough / Resistant / Easy to strip (gel free) /Reduced diameter / Direct connectorization / Saves installation costs / Excellent rodent protection.

SPECIFICATIONS

Fibres 2 4 6 8 12

Strength Members Reinforced Fiberglass Yarns (WB)

Inner jacket Thermoplastic

Armour Steel Wires Braid

Outer jacket Thermoplastic LSZH1

Colour Black

Weight (Kg/Km) 98 104 111 133 157

ø Outer (mm) 9.0 ±0.3 9.3 ±0.3 9.5 ±0.3 10.7 ±0.3 11.5 ±0.3

Tensile Load Perm / Inst (N) 700 / 1250 800 / 1450 900 / 1600

Crush (N) 1500

Temperature Range -20 ºC to +70 ºC

Min. Bending Radius 20 x ø Outer

Maximum Length 4200 m

01. TIGHT BUFFER FIBRE02. REINFORCED FIBERGLASS YARNS03. INNER JACKET.04. METALLIC ARMOUR05. OUTER JACKET

04

02

01

03

05

06

SPECIFICATIONS

Fibres 2 4 6 8 12 16Subcables strength members Aramid Yarns

ø Subcables (mm) 2.5Subcables jacket ThermoplasticColour Orange (MM62) / Blue (MM50) / Yellow (SM)Identification NumbersInner jacket Thermoplastic LSZH1

Armour Steel Wires BraidOuter jacket Thermoplastic LSZH1

Colour Orange (MM62) / Blue (MM50) / Yellow (SM)Weight (Kg/Km) 123 135 183 218 263 372ø Outer (mm) 10.9 ±0.5 10.9 ±0.5 13.0 ±0.5 14.5 ±0.5 15.5 ±0.5 17.3 ±0.5

Tensile Load Perm / Inst (N) 900/1600 1100/2000 1500/2700 1900/3400 2700/4000 3000/4000Crush (N) 2000Temperature Range -20 ºC to +70 ºCMin. Bending Radius 20 x ø OuterMax. Length 4200 mStandards

Environmental and mechanical tests according to EN 187000 and CEI 60794.Fire test according to: UNE-EN 50266(IEC 60332-3) / UNE-EN 50267(IEC 60754-1) / UNE-EN 50268(IEC 61034-1/2)Fibres colour code: red, green, grey , yellow.1LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.

StandardsEnvironmental and mechanical tests according to: EN 187000 and CEI 60794.Fire test according to: UNE-EN 50266(IEC 60332-3) / UNE-EN 50267(IEC 60754-1) / UNE-EN 50268(IEC 61034-1/2)1 LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794.Fire test according to: UNE-EN 50266(IEC 60332-3)/UNE-EN 50267(IEC 60754-1)/UNE-EN 50268(IEC 61034-1/2).1 LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794.Fire test according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267 (IEC 60754-1) / UNE-EN 50268 (IEC 61034-1/2).Fibres colour code: red, green, grey, yellow, blue, natural, white, brown, violet, orange, pink, black.1LSZH – Halogen free, low smoke emissions and flame retardant thermoplastic compound.

0502

01

03 04

Page 12: Optical fibre cables and optoelectronic converters - Policie

p.12

Loose tube cables

Loose tube cables

Nexo (DT)

Indo

or /

Out

door

01. FIBRES OPTICS02. CENTRAL TUBE (JELLY FILLED)03. FIBERGLASS REINFORCEMENTS - WB04. RIPCORD05. OUTER JACKET

Cable Description•FibresOptics•CentralTube(Jellyfilled)•FiberglassReinforcements-WB•Ripcord•OuterJacket

Fire Resistance•Flameretardant•Halogenfree•Lowsmokeemission

Applications•Universal(Indoor/Outdoor)

Rodent protection•Rodentprotected

Options•StrengthMembers:Aramid(KTType)•Specialcolourcode(TIA598)

Advantages•Compact/Lightweight/Flexible/ Tough / Resistant / Totally dielectric / Watertight / Reduced diameter / Rodent protected.

SPECIFICATIONS

Fibres 2 4 6 8 12 16 24

ø Central Tube (mm) 3.2 ± 0.2 4.2 ± 0.2

Strength members Fiberglass Reinforcements WB (Waterblocking)

Outer jacket Thermoplastic LSZH1

Colour Dark Grey

Weight (Kg/Km) 53 60

ø Outer (mm) 7.0 ± 0.3 7.9 ± 0.3

Tensile Load Perm / Inst (N) 1000 / 180

Crush (N) 1500

Temperature Range -30º C to +70º C

Min. Bending Radius 20 x ø Outer

Maximum Length (m) 4000 m 2000 m

SPECIFICATIONS

Fibres 2 4 6 8 12 16 24

ø Central Tube (mm) 3.2 ± 0.2 4.2 ± 0.2

Strength members Reinforced Fiberglass yarns WB (Waterblocking)

Outer jacket Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 40 50

ø Outer (mm) 7.0 ± 0.3 7.9 ± 0.3

Tensile Load Perm / Inst (N) 1000 / 1800

Crush (N) 1500

Temperature Range -40º C to +70º C

Min. Bending Radius 20 x ø Outer

Maximum Length (m) 4000 m 2000 m

02

01

03

0405

Nexo (DP)

Indo

or /

Out

door

01. FIBRE OPTICS02. CENTRAL TUBE (JELLY FILLED)03. FIBERGLASS REINFORCEMENTS - WB04. RIPCORD05. OUTER JACKET

Cable Description•FibreOptics•CentralTube(Jellyfilled)•FiberglassReinforcements-WB•Ripcord•OuterJacket

Applications•Outdoor

Rodent protection•Rodentprotected

Options•StrengthMembers=Aramid(KPType)•Specialcolourcode(TIA598)

Advantages•Compact/Lightweight/Flexible Tough / Resistant / Totally dielectric / Watertight / Reduced diameter / Excellent resistance to friction / Suitable for “blown air” system / Rodent protected.

02

01

03

0405

SPECIFICATIONS

Fibre Count 16 24 32 36 48 64 72 96 128 144

Fibres per Tube 4 6 8 6 12 8 12 12 8 12

Total Tubes 4 4 4 6 4 8 6 8 18 14

Active Tubes 4 4 4 6 4 8 6 8 16 12

Strength members Reinforced Fiberglass Yarns WB (Waterblocking)

Compound Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 63 64 74 82 84 134 119 157 194 181

ø Outer (mm) 9.3±0.5 9.3±0.5 10.2±0.5 10.5±0.5 11.0±0.5 13.2±0.5 12.6±0.5 14.3±0.5 16.7±0.5 17.0±0.5

Tensile Load Perm / Inst (N) 1000 / 1800 1500 / 2700

Crush (N) 2000

Maximum Length (m) 4200 4200 3100 4200 2100 3100 2100 2100 3100 2100

Temperature Range -40º C to +70º C

Min. Bending Radius 20 x ø Outer

SPECIFICATIONS

Fibre Count 2 4 6 8 12 16 24

ø Central Tube (mm) 3.2 ± 0.2 4.2 ± 0.2

Strength members Fiberglass yarns WB (Waterblocking)

Outer jacket Polyethylene

Colour Black

Weight (Kg/Km) 67 77

ø Outer (mm) 8.4 ± 0.3 9 ± 0.3

Tensile Load Perm / Inst (N) 3000 / 4000

Crush (N/10cm) 1500

Temperature Range -40º C to +70º C

Min. Bending Radius 20 x ø Outer

Maximum Length (m) 4000 m 2000 m

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794.Fire test according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267 (IEC 60754-1) / UNE-EN 50268 (IEC 61034-1/2).Fibres colour code: Red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise. With stripe: red, green, yellow, blue, white, violet, orange, natural, grey, brown, pink, turquoise.1 LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794.Fibres colour code: Red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise. With stripe: red, green, yellow, blue, white, violet, orange, natural, grey, brown, pink, turquoise.

Page 13: Optical fibre cables and optoelectronic converters - Policie

p.13

Loose tube cables

Loose tube cables

SPECIFICATIONS

Fibres 2 4 6 8 12 16 24

ø Central Tube (mm) 3.2 ± 0.2 4.2 ± 0.2

Strength members Fiberglass Reinforcements WB (Waterblocking)

Outer jacket Thermoplastic LSZH1

Colour Dark Grey

Weight (Kg/Km) 53 60

ø Outer (mm) 7.0 ± 0.3 7.9 ± 0.3

Tensile Load Perm / Inst (N) 1000 / 180

Crush (N) 1500

Temperature Range -30º C to +70º C

Min. Bending Radius 20 x ø Outer

Maximum Length (m) 4000 m 2000 m

SPECIFICATIONS

Fibres 2 4 6 8 12 16 24

ø Central Tube (mm) 3.2 ± 0.2 4.2 ± 0.2

Strength members Reinforced Fiberglass yarns WB (Waterblocking)

Outer jacket Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 40 50

ø Outer (mm) 7.0 ± 0.3 7.9 ± 0.3

Tensile Load Perm / Inst (N) 1000 / 1800

Crush (N) 1500

Temperature Range -40º C to +70º C

Min. Bending Radius 20 x ø Outer

Maximum Length (m) 4000 m 2000 m

DP

Indo

or /

Out

door

01 CENTRAL ELEMENT (GRP)02 FIBRE OPTICS03 LOOSE TUBE (JELLY FILLED)04 FIBERGLASS REINFORCEMENTS - WB05 RIPCORD06 OUTER JACKET

Cable Description •Central Element (GRP)•Fibre Optics•Loose Tube (Jelly Filled)•Fiberglass Reinforcements - WB•Ripcord•Outer Jacket

Applications•Outdoor

Rodent protection•Rodent protected

Options•StrengthMembers=Aramid(KPType)•Special colour code (TIA 598)

Advantages•Compact / Tough / Resistant / Totally dielectric / Excellent resistance to friction / Suitable for “blown air” system.

SPECIFICATIONS

Fibre Count 16 24 32 36 48 64 72 96 128 144

Fibres per Tube 4 6 8 6 12 8 12 12 8 12

Total Tubes 4 4 4 6 4 8 6 8 18 14

Active Tubes 4 4 4 6 4 8 6 8 16 12

Strength members Reinforced Fiberglass Yarns WB (Waterblocking)

Compound Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 63 64 74 82 84 134 119 157 194 181

ø Outer (mm) 9.3±0.5 9.3±0.5 10.2±0.5 10.5±0.5 11.0±0.5 13.2±0.5 12.6±0.5 14.3±0.5 16.7±0.5 17.0±0.5

Tensile Load Perm / Inst (N) 1000 / 1800 1500 / 2700

Crush (N) 2000

Maximum Length (m) 4200 4200 3100 4200 2100 3100 2100 2100 3100 2100

Temperature Range -40º C to +70º C

Min. Bending Radius 20 x ø Outer

03

05

04

02

01

06

Tenax DPIn

door

/ O

utdo

or

Cable Description• Fibre Optics• Central Tube (Jelly filled)• Fiberglass Reinforcements – WB• Ripcord• Outer Jacket

Applications•Outdoor• Aerial Installation

Rodent protection•Rodent Protected

Options•Special colour code (TIA 598)

Advantages•Compact / Lightweight / Flexible / Tough / Resistant / Watertight / Exce llent mechanical resistance / Com pletely Dielectric / Small diameter / Excellent resistance to friction / Suitable for “air blowing” systems / Rodent protected / Aerial installation.

01. FIBRE OPTICS02. CENTRAL TUBE (JELLY FILLED)03. FIBERGLASS REINFORCEMENTS – WB04. RIPCORD05. OUTER JACKET

02

01

03

04

SPECIFICATIONS

Fibre Count 2 4 6 8 12 16 24

ø Central Tube (mm) 3.2 ± 0.2 4.2 ± 0.2

Strength members Fiberglass yarns WB (Waterblocking)

Outer jacket Polyethylene

Colour Black

Weight (Kg/Km) 67 77

ø Outer (mm) 8.4 ± 0.3 9 ± 0.3

Tensile Load Perm / Inst (N) 3000 / 4000

Crush (N/10cm) 1500

Temperature Range -40º C to +70º C

Min. Bending Radius 20 x ø Outer

Maximum Length (m) 4000 m 2000 m

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794.Fire test according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267 (IEC 60754-1) / UNE-EN 50268 (IEC 61034-1/2).Fibres colour code: Red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise. With stripe: red, green, yellow, blue, white, violet, orange, natural, grey, brown, pink, turquoise.1 LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.

Aerial Installation ConditionsWind Ice Thickness Span(Km/h) (mm) (m)

100 0 110

0 10 90

0 15 50

60 10 70

NESC Installation Conditions Span (m)NESC Light 100NESC Medium 60

StandardsEnvironmental and mechanical tests according to EN 187000 and IEC 60794.Fibres colour code: Red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise. With black ring: red, green,yellow, blue, white, violet, orange, natural, grey, brown, pink, turquoise.

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794.Fibres colour code: red, green, blue, yellow, grey, violet, brown, orange, white, pink, black and natural.

Page 14: Optical fibre cables and optoelectronic converters - Policie

p.14

Loose tube cables

Loose tube cables

PKP

Die

lect

ric

Out

door

01. CENTRAL ELEMENT (GRP)02. FIBRE OPTICS03. LOOSE TUBE (JELLY FILLED)04. RIPCORD05. INNER JACKET06. ARAMID07. RIPCORD08. OUTER JACKET

Cable Description•CentralElement(GRP)•FibreOptics•Loosetube(jellyfilled)•Ripcord•InnerJacket•Aramid•Ripcord•OuterJacket

Applications•Outdoor

Options•StrengthMembers:Reinforced fiberglass yarns•Specialcolourcode(TIA598)

Advantages•Excellentmechanicalresistance/ Totally dielectric / Resistant / Tough / High density of fibres / Excellent resistance to friction.

SPECIFICATIONS

Fibre Count 4 6 8 12 16 24 32 36 48 64 72 96 128 144

Fibres per tube 4 2 4 4 4 6 8 6 12 8 12 12 8 12

Total tubes 4 4 4 4 4 4 4 6 4 8 6 8 18 14

Active tubes 1 3 2 3 4 4 4 6 4 8 6 8 16 12

Inner jacket Lineal Low Density Polyethylene

Strength Members Aramid Yarns

Outer jacket Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 83 86 84 86 87 88 101 109 113 169 152 195 238 225

ø Outer (mm) 11.1±0.5 11.1±0.5 11.1±0.5 11.1±0.5 11.1±0.5 11.1±0.5 12.0±0.5 12.3±0.5 12.8±0.5 15.0±0.5 14.4±0.5 16.1±0.5 18.5±0.5 18.8±0.5

Tensile load Perm / Inst (N)

1000 1000 1000 1000 1000 1000 1000 1000 1000 1500 1500 1500 1500 1500

Crush (N) 2000

Max. Length 4200 4200 4200 4200 4200 4200 3100 4200 2100 3100 2100 2100 3100 2100

Temperature range -40º C to +70ºC

Min. Bending radius (mm) 20 x ø Outer

DPDP

Die

lect

ric

Out

door

01. CENTRAL ELEMENT (GRP)02. FIBRE OPTIC03. LOOSE TUBE (JELLY FILLED)04. FIBERGLASS REINFORCEMENTS - WB05. RIPCORD06. INNER JACKET07. DIELECTRIC ARMOUR08. RIPCORD09. OUTER JACKET

Cable Description•CentralElement(GRP)•FibreOptic•LooseTube(JellyFilled)•FiberglassReinforcements-WB•Ripcord• InnerJacket•DielectricArmour•Ripcord•OuterJacket

Applications•Outdoor

Rodent protection•Rodentresistant

Options•StrengthMembers=Aramid (KPDP Type)•Specialcolourcode(TIA598)

Advantages•Compact/Tough/Resistant / Totally dielectric / Excellent Resistance to Friction / Suitable for “blown air” system / Moderate rodent protection

0305

02

010704

06

06

04

01

07

05

08

03

02

SPECIFICATIONS

Fibres 16 24 32 36 48 64 72 96 128 144

Fibres per Tube 4 6 8 6 12 8 12 12 8 12

Total Tubes 4 4 4 6 4 8 6 8 18 14

Active Tubes 4 4 4 6 4 8 6 8 16 12

Strength Members Reinforced Fiberglass Yarns WB (Water Blocking)

Inner jacket Lineal Low Density Polyethylene

Armour Fiberglass Braid

Outer jacket Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 112 112 127 135 139 198 181 225 271 259

ø Outer (mm) 11.9±0.5 11.9±0.5 12.8±0.5 13.1±0.5 13.6±0.5 15.8±0.5 15.2±0.5 16.9±0.5 19.3±0.5 19.6±0.5

Tensile Load Perm / Inst (N) 1200 / 2150 1700 / 3050

Crush (N) 3000

Maximum Length (m) 4200 4200 3100 4200 2100 3100 2100 2100 3100 2100

Temperature Range -40º C to +70º C

Min. Bending Radius 20 x ø Outer

SPECIFICATIONS

Fibres 2 4 6 8 12 16 24

ø Central Tube (mm) 3.2 ±0.2 / 3.5 ±0.2 (12 FO) 4.5 ±0.2

Strength Members Fibras Vidrio Reforzadas WB (Bloqueantes Agua)

Inner jacket Lineal Low Density Polyethylene

Armour Steel Wire Braid

Outer jacket Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 96 / 101 (12 FO) 117

ø Outer (mm) 9.8 ± 0.5 / 10.1 ± 0.5 (12 FO) 11.1 ± 0.5

Tensile load Perm / Inst (N) 1300 / 2350

Crush (N) 2000

Temperature range -40º C to +70ºC

Min. Bending radius (mm) 20 x ø Outer

Max. Length 4200 m / 3200 m (12 FO) 2000 m

SPECIFICATIONS

Fibres 16 24 32 36 48 64 72 96 128 144

Fibres per Tube 4 6 8 6 12 8 12 12 8 12

Total Tubes 4 4 4 6 4 8 6 8 18 14

Active Tubes 4 4 4 6 4 8 6 8 16 12

Strength Members Reinforced Fiberglass Yarns WB (Water Blocking)

Inner jacket Lineal Low Density Polyethylene

Armour Steel Wire Braid

Outer jacket Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 128 128 144 153 158 223 205 257 309 298

ø Outer (mm) 11.9±0.5 11.9±0.5 12.8±0.5 13.1±0.5 13.6±0.5 15.8±0.5 15.2±0.5 16.9±0.5 19.3±0.5 19.6±0.5

Tensile Load Perm / Inst (N) 1300 / 2350 1800 / 3250

Crush (N) 3000

Maximum Length (m) 4200 4200 3100 4200 2100 3100 2100 2100 3100 2100

Temperature Range -40º C to +70º C

Min. Bending Radius 20 x ø Outer

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794.

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794.Fibres colour code: red, green, blue, yellow, grey, violet, brown, orange, white, pink, black and natural.

Page 15: Optical fibre cables and optoelectronic converters - Policie

p.15

Loose tube cables

Loose tube cables

SPECIFICATIONS

Fibre Count 4 6 8 12 16 24 32 36 48 64 72 96 128 144

Fibres per tube 4 2 4 4 4 6 8 6 12 8 12 12 8 12

Total tubes 4 4 4 4 4 4 4 6 4 8 6 8 18 14

Active tubes 1 3 2 3 4 4 4 6 4 8 6 8 16 12

Inner jacket Lineal Low Density Polyethylene

Strength Members Aramid Yarns

Outer jacket Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 83 86 84 86 87 88 101 109 113 169 152 195 238 225

ø Outer (mm) 11.1±0.5 11.1±0.5 11.1±0.5 11.1±0.5 11.1±0.5 11.1±0.5 12.0±0.5 12.3±0.5 12.8±0.5 15.0±0.5 14.4±0.5 16.1±0.5 18.5±0.5 18.8±0.5

Tensile load Perm / Inst (N)

1000 1000 1000 1000 1000 1000 1000 1000 1000 1500 1500 1500 1500 1500

Crush (N) 2000

Max. Length 4200 4200 4200 4200 4200 4200 3100 4200 2100 3100 2100 2100 3100 2100

Temperature range -40º C to +70ºC

Min. Bending radius (mm) 20 x ø Outer

SPECIFICATIONS

Fibres 16 24 32 36 48 64 72 96 128 144

Fibres per Tube 4 6 8 6 12 8 12 12 8 12

Total Tubes 4 4 4 6 4 8 6 8 18 14

Active Tubes 4 4 4 6 4 8 6 8 16 12

Strength Members Reinforced Fiberglass Yarns WB (Water Blocking)

Inner jacket Lineal Low Density Polyethylene

Armour Fiberglass Braid

Outer jacket Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 112 112 127 135 139 198 181 225 271 259

ø Outer (mm) 11.9±0.5 11.9±0.5 12.8±0.5 13.1±0.5 13.6±0.5 15.8±0.5 15.2±0.5 16.9±0.5 19.3±0.5 19.6±0.5

Tensile Load Perm / Inst (N) 1200 / 2150 1700 / 3050

Crush (N) 3000

Maximum Length (m) 4200 4200 3100 4200 2100 3100 2100 2100 3100 2100

Temperature Range -40º C to +70º C

Min. Bending Radius 20 x ø Outer

DPMP-1

Met

allic

Out

door

01. FIBRE OPTICS02. CENTRAL TUBE (JELLY FILLED)03. FIBERGLASS REINFORCEMENTS - WB04. RIPCORD05. INNER JACKET06. METALLIC ARMOUR07. RIPCORD08. OUTER JACKET

Cable Description•Fibre Optics•Central Tube (Jelly filled)•Fiberglass Reinforcements - WB•Ripcord•Inner Jacket•Metallic Armour•Ripcord•Outer Jacket

Applications•Outdoor

Rodent protection•Excellent rodent resistence

Options•StrengthMembers=Aramid(KPMP- 1 Type)•Special colour code (TIA 598)

Advantages•Compact / Lightweight / Flexible / Tough / Resistant / Reduced diameter / Watertight / Excellent Resistance to Friction / Suitable for “blown air” system / Excellent rodent resistance.

02

01 0407

05

06

03

SPECIFICATIONS

Fibres 2 4 6 8 12 16 24

ø Central Tube (mm) 3.2 ±0.2 / 3.5 ±0.2 (12 FO) 4.5 ±0.2

Strength Members Fibras Vidrio Reforzadas WB (Bloqueantes Agua)

Inner jacket Lineal Low Density Polyethylene

Armour Steel Wire Braid

Outer jacket Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 96 / 101 (12 FO) 117

ø Outer (mm) 9.8 ± 0.5 / 10.1 ± 0.5 (12 FO) 11.1 ± 0.5

Tensile load Perm / Inst (N) 1300 / 2350

Crush (N) 2000

Temperature range -40º C to +70ºC

Min. Bending radius (mm) 20 x ø Outer

Max. Length 4200 m / 3200 m (12 FO) 2000 m

DPMPM

etal

lic O

utdo

or

01. CENTRAL ELEMENT (GRP)02. FIBRE OPTICS03. LOOSE TUBE (JELLY FILLED)04. FIBERGLASS REINFORCEMENTS - WB05. RIPCORD06. INNER JACKET07. METALLIC ARMOUR08. RIPCORD09. OUTER JACKET

Cable Description•Central Element (GRP)•Fibre Optics•Loose Tube (Jelly Filled)•Fiberglass Reinforcements - WB•Ripcord•Inner Jacket•Metallic Armour•Ripcord•Outer Jacket

Applications•Outdoor

Rodent protection•Excellent rodent resistence

Options•StrengthMembers=Aramid(KPMP Type)•Special colour code (TIA 598)

Advantages•Compact / Tough / Resistant / Excellent Resistance to Friction / Suitable for “blown air” system / Excellent rodent protection.

SPECIFICATIONS

Fibres 16 24 32 36 48 64 72 96 128 144

Fibres per Tube 4 6 8 6 12 8 12 12 8 12

Total Tubes 4 4 4 6 4 8 6 8 18 14

Active Tubes 4 4 4 6 4 8 6 8 16 12

Strength Members Reinforced Fiberglass Yarns WB (Water Blocking)

Inner jacket Lineal Low Density Polyethylene

Armour Steel Wire Braid

Outer jacket Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 128 128 144 153 158 223 205 257 309 298

ø Outer (mm) 11.9±0.5 11.9±0.5 12.8±0.5 13.1±0.5 13.6±0.5 15.8±0.5 15.2±0.5 16.9±0.5 19.3±0.5 19.6±0.5

Tensile Load Perm / Inst (N) 1300 / 2350 1800 / 3250

Crush (N) 3000

Maximum Length (m) 4200 4200 3100 4200 2100 3100 2100 2100 3100 2100

Temperature Range -40º C to +70º C

Min. Bending Radius 20 x ø Outer

03

07

04

02

01

06

05

08

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794.Fibres colour code: Red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise. With stripe: red, green, yellow, blue, white, violet, orange, natural, grey, brown, pink, turquoise.

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794.Fibres colour code: red, green, blue, yellow, grey, violet, brown, orange, white, pink, black and natural.

Page 16: Optical fibre cables and optoelectronic converters - Policie

p.16

Loose tube cables

Loose tube cables

DSP-1

Met

allic

out

door

01. FIBRE OPTICS02. CENTRAL TUBE (JELLY FILLED)03. FIBERGLASS REINFORCEMENTS - WB04. METALLIC ARMOUR05. RIPCORD06. OUTER JACKET

Cable Description•FibreOptics•CentralTube(Jellyfilled)•FiberglassReinforcements-WB•MetallicArmour•Ripcord•OuterJacket

Applications•Outdoor

Rodent protection•Excellentrodentresistance

Options•StrengthMembers=AramidYarns (KSP-1 Type)•Specialcolourcode(TIA598)

Advantages•Compact/Tough/Resistant/Reduced diameter / Watertight / Excellent resistance to friction / Suitable for “blown air” system / Excellent resistance to rodents.

02

01

03

0504

06

SPECIFICATIONS

Fibres 2 4 6 8 12 16 24

ø Central Tube (mm) 4.5 ±0.2

Strength Members Reinforced Fiberglass Yarns WB (Waterblocking)

Armour Corrugated Steel Armour

Outer jacket Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 88

ø Outer (mm) 9.6 ±0.3

Tensile Load Perm / Inst (N) 1500 / 2700

Crush (N) 2000

Temperature Range -40º C to +70ºC

Min. Bending Radius 20 x ø Outer

Maximum Length 2000 m

DSP

Met

allic

out

door

01. CENTRAL ELEMENT (GRP)02. FIBRE OPTICS03. LOOSE TUBE (JELLY FILLED)04. FIBERGLASS REINFORCEMENTS - WB05. METALLIC ARMOUR06. RIPCORD07. OUTER JACKET

Cable Description•CentralElement(GRP)•FibreOptics•LooseTube(JellyFilled)•FiberglassReinforcements-WB•MetallicArmour•Ripcord•OuterJacket

Applications•Outdoor

Rodent protection•Excellentrodentresistance

Options•StrengthMembers=Aramid (KSP Type)•Specialcolourcode(TIA598)

Advantages•Compact/Tough/Resistant/ Excellent resistance to friction / Suitable for “blown air” system / Excellent rodent protection.

0304

02

01

06

05

SPECIFICATIONS

Fibres 2 4 6 8 12 16 24

ø Central Tube (mm) 3.2 ±0.2 4.5 ±0.2

Strength Members Reinforced Fiberglass Yarns WB (Waterblocking)

Inner jacket Lineal Low Density Polyethylene

Armour Corrugated Steel Armour

Outer jacket Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 95 135

ø Outer (mm) 9.6 ±0.3 12.6 ±0.5

Tensile Load Perm / Inst (N) 1500 / 2700

Crush (N) 2000

Temperature Range -40º C to +70ºC

Min. Bending Radius 20 x ø Outer

Maximum Length 4000 m 2000 m

SPECIFICATIONS

Fibres 16 24 32 36 48 64 72 96 128 144

Fibres per Tube 4 6 8 6 8 8 12 12 8 12

Total Tubes 4 4 6 6 6 8 8 8 18 14

Active Tubes 4 4 4 6 6 8 6 8 16 12

Strength Members Reinforced Fiberglass Yarns WB (Waterblocking)

Inner jacket Lineal Low Density Polyethylene

Armour Corrugated Steel Armour

Outer jacket Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 140 141 191 195 196 274 265 272 336 327

ø Outer (mm) 12.5±0.5 12.5±0.5 15.3±0.5 15.3±0.5 15.3±0.5 18.3±0.5 18.3±0.5 18.3±0.5 21.4±0.5 21.4±0.5

Tensile Load Perm / Inst (N) 2000 / 3600

Crush (N 3000

Maximum Length (m) 4200 4200 3100 3100 3100 2100 2100 2100 3100 2100

Temperature Range -40º C to +70º C

Min. Bending Radius 20 x ø Outer

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794.Fibres colour code: Red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise. With stripe: red, green, yellow, blue, white, violet, orange, natural, grey, brown, pink, turquoise.

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794.Fibres colour code: Red, green, blue, yellow, grey, violet, brown, orange, white, pink, black and natural.

SPECIFICATIONS

Fibres 16 24 32 36 48 64 72 96 128 144

Fibres per Tube 4 6 8 6 8 8 12 12 8 12

Total Tubes 4 4 6 6 6 8 8 8 18 14

Active Tubes 4 4 4 6 6 8 6 8 16 12

Strength Members Reinforced Fiberglass Yarns WB (Waterblocking)

Armour Corrugated Steel Armour

Outer jacket Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 98 98 143 148 148 220 215 222 269 261

ø Outer (mm) 10.0±0.5 10.0±0.5 12.5±0.5 12.5±0.5 12.5±0.5 16.0±0.5 16.0±0.5 16.0±0.5 18.5±0.5 18.5±0.5

Tensile Load Perm / Inst (N) 2000 / 3600

Crush (N) 2500

Maximum Length (m) 4200 4200 3100 3100 3100 2100 2100 2100 3100 2100

Temperature Range -40º C to +70º C

Min. Bending Radius 20 x ø Outer

Page 17: Optical fibre cables and optoelectronic converters - Policie

p.17

Loose tube cables

Loose tube cables

SPECIFICATIONS

Fibres 2 4 6 8 12 16 24

ø Central Tube (mm) 4.5 ±0.2

Strength Members Reinforced Fiberglass Yarns WB (Waterblocking)

Armour Corrugated Steel Armour

Outer jacket Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 88

ø Outer (mm) 9.6 ±0.3

Tensile Load Perm / Inst (N) 1500 / 2700

Crush (N) 2000

Temperature Range -40º C to +70ºC

Min. Bending Radius 20 x ø Outer

Maximum Length 2000 m

01. FIBRAS ÓPTICAS02. MONOTUBO CENTRAL RELLENO DE GEL03. FIBRAS VIDRIO REFORZADAS – WB 04. CUBIERTA TERMOPLÁSTICA INTERIOR05. ARMADURA ACERO CORRUGADO06. CUBIERTA TERMOPLÁSTICA EXTERIOR

SPECIFICATIONS

Fibres 2 4 6 8 12 16 24

ø Central Tube (mm) 3.2 ±0.2 4.5 ±0.2

Strength Members Reinforced Fiberglass Yarns WB (Waterblocking)

Inner jacket Lineal Low Density Polyethylene

Armour Corrugated Steel Armour

Outer jacket Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 95 135

ø Outer (mm) 9.6 ±0.3 12.6 ±0.5

Tensile Load Perm / Inst (N) 1500 / 2700

Crush (N) 2000

Temperature Range -40º C to +70ºC

Min. Bending Radius 20 x ø Outer

Maximum Length 4000 m 2000 m

DPSP-1

Met

allic

out

door

Cable Description •Fibre Optics•Central Tube (Jelly filled)•Fiberglass Reinforcements - WB•Ripcord•Inner Jacket•Metallic Armour•Ripcord•Outer Jacket

Applications•Outdoor

Rodent protection•Excellent rodent resistance

Options•StrengthMembers=Aramid (KPSP-1 Type)•Special colour code (TIA 598)

Advantages•Compact / Tough / Resistant / Watertight / Excellent resistance to friction / Suitable for “blown air” system / Excellent resistance to rodents.

02

01 0406

05

03

DPSPM

etal

lic o

utdo

or

Cable Description•Central Element (GRP)•Fibre Optics•Loose Tube (Jelly Filled)•Fiberglass Reinforcements WB•Ripcord•Inner Jacket•Metallic Armour•Ripcord•Outer Jacket

Applications•Outdoor

Rodent protection•Excellent rodent resistance

Options•StrengthMembers=Aramid (KPSP Type)•Special colour code (TIA 598)

Advantages•Compact / Tough / Resistant / Excellent resistance to friction / Suitable for “blown air” system / Excellent rodent protection.

04

01

04

05

07

03

02

01. CENTRAL ELEMENT (GRP)02. FIBRE OPTICS03. LOOSE TUBE (JELLY FILLED)04. FIBERGLASS REINFORCEMENTS WB05. RIPCORD06. INNER JACKET07. METALLIC ARMOUR08. RIPCORD09. OUTER JACKET

SPECIFICATIONS

Fibres 16 24 32 36 48 64 72 96 128 144

Fibres per Tube 4 6 8 6 8 8 12 12 8 12

Total Tubes 4 4 6 6 6 8 8 8 18 14

Active Tubes 4 4 4 6 6 8 6 8 16 12

Strength Members Reinforced Fiberglass Yarns WB (Waterblocking)

Inner jacket Lineal Low Density Polyethylene

Armour Corrugated Steel Armour

Outer jacket Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 140 141 191 195 196 274 265 272 336 327

ø Outer (mm) 12.5±0.5 12.5±0.5 15.3±0.5 15.3±0.5 15.3±0.5 18.3±0.5 18.3±0.5 18.3±0.5 21.4±0.5 21.4±0.5

Tensile Load Perm / Inst (N) 2000 / 3600

Crush (N 3000

Maximum Length (m) 4200 4200 3100 3100 3100 2100 2100 2100 3100 2100

Temperature Range -40º C to +70º C

Min. Bending Radius 20 x ø Outer

01. FIBRE OPTICS02. CENTRAL TUBE (JELLY FILLED)03. FIBERGLASS REINFORCEMENTS - WB04. RIPCORD05. INNER JACKET06. METALLIC ARMOUR07. RIPCORD08. OUTER JACKET

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794.Fibres colour code: Red, green, blue, yellow, grey, violet, brown, orange, white, pink, black and natural.

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794.Fibres colour code: Red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise. With stripe: red, green, yellow, blue, white, violet, orange, natural, grey, brown, pink, turquoise.

StandardsEnvironmental and mechanical tests according to EN 187000 and CEI 60794.Fibres colour code: Red, green, blue, yellow, grey, violet, brown, orange, white, pink, black and natural.

SPECIFICATIONS

Fibres 16 24 32 36 48 64 72 96 128 144

Fibres per Tube 4 6 8 6 8 8 12 12 8 12

Total Tubes 4 4 6 6 6 8 8 8 18 14

Active Tubes 4 4 4 6 6 8 6 8 16 12

Strength Members Reinforced Fiberglass Yarns WB (Waterblocking)

Armour Corrugated Steel Armour

Outer jacket Lineal Low Density Polyethylene

Colour Black

Weight (Kg/Km) 98 98 143 148 148 220 215 222 269 261

ø Outer (mm) 10.0±0.5 10.0±0.5 12.5±0.5 12.5±0.5 12.5±0.5 16.0±0.5 16.0±0.5 16.0±0.5 18.5±0.5 18.5±0.5

Tensile Load Perm / Inst (N) 2000 / 3600

Crush (N) 2500

Maximum Length (m) 4200 4200 3100 3100 3100 2100 2100 2100 3100 2100

Temperature Range -40º C to +70º C

Min. Bending Radius 20 x ø Outer

Page 18: Optical fibre cables and optoelectronic converters - Policie

p.18

SPECIFICATIONS

Vano Máximo 80 m | 120 m | 150 m | 200 mFibres 4 6 8 12 16 24 32 36 48 64 72 96Fibres per Tube 2 2 2 2 4 4 8 6 8 8 12 12Total Tubes 6 6 6 6 6 6 6 6 6 8 6 8Inner Jacket PolyethyleneStrength Members Aramid YarnsOuter Jacket PolyethyleneColour BlackMAT (N) 80 m: 3000 120 m: 4000 150 m: 6000 200 m: 8000EDS (N) 80 m: 1200 80 m: 1600 80 m: 2400 80 m: 3200Impact 5JTemperature Range -40º C to +70º CMin. Bending Radius 20 x ø Outer

ADSS 80 / 120 / 150 / 200

Sel

f-su

ppor

ted

01. CENTRAL FILLER02. FIBRE OPTICS03. LOOSE TUBE (JELLY FILLED)04. INNER JACKET05. ARAMID06. RIPCORD07. OUTER JACKET

Cable Description•CentralFiller•FibreOptics•Loosetube(jellyfilled)•Innerjacket•Aramid•Ripcord•Outerjacket

Applications•AerialInstallations

Options•Anti-TrackingJacket•BallisticProtection•SpecialColourCode(TIA598)

Advantages•Excellentmechanicalresistance/Totallydielectric/Tough/ Resistant / High density of fibres / Self-supported aerial applications.

0305

02

010704

06

80 mWeight (Kg/Km) 111 113 115 120 116 120 133 121 139 175 141 177ø Outer 12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5 13.3 ± 0.5 12.4 ± 0.5 13.3 ± 0.5 15 ± 0.5 13.3 ± 0.5 15 ± 0.5

Maximum Length 3200 3200 3200 3200 3200 3200 2100 3200 2100 2100 2100 2100

120 mWeight (Kg/Km) 113 115 117 122 118 123 133 123 142 177 143 179ø Outer 12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5 13.3 ± 0.5 12.4 ± 0.5 13.3 ± 0.5 15 ± 0.5 13.3 ± 0.5 15 ± 0.5

Maximum Length 3200 3200 3200 3200 3200 3200 2100 3200 2100 2100 2100 2100

150 mWeight (Kg/Km) 118 120 123 127 123 128 141 128 147 182 148 184ø Outer 12.7 ± 0.5 12.7 ± 0.5 12.7 ± 0.5 12.7 ± 0.5 12.7 ± 0.5 12.7 ± 0.5 13.6 ± 0.5 12.7 ± 0.5 13.6 ± 0.5 15.3 ± 0.5 13.6 ± 0.5 15.3 ± 0.5

Maximum Length 3200 3200 3200 3200 3200 3200 2100 3200 2100 2100 2100 2100

200 mWeight (Kg/Km) 123 125 127 132 128 132 145 133 151 186 153 188ø Outer 12.8 ± 0.5 12.8 ± 0.5 12.8 ± 0.5 12.8 ± 0.5 12.8 ± 0.5 12.8 ± 0.5 13.7 ± 0.5 12.8 ± 0.5 13.7 ± 0.5 15.3 ± 0.5 13.7 ± 0.5 15.3 ± 0.5

Maximum Length 3200 3200 3200 3200 3200 3200 2100 3200 2100 2100 2100 2100

SPECIFICATIONS

Fibres 4 6 8 12 16 24 32 36 48 64 72 96

Fibres per Tube 2 2 2 2 4 4 8 6 8 8 12 12

Total Tubes 6 6 6 6 6 6 6 6 6 8 6 8

Strength Members Aramid Yarns

Outer Jacket Polyethylene

Colour Black

Weight (Kg/Km) 68 69 70 73 71 73 87 74 92 119 94 121

ø Outer (mm) 9.7±0.5 9.7±0.5 9.7±0.5 9.7±0.5 9.7±0.5 9.7±0.5 10.9±0.5 9.7±0.5 10.9±0.5 12.4±0.5 10.9±0.5 12.4±0.5

Maximum Length (mm) 3200 3200 3200 3200 3200 3200 2100 3200 2100 2100 2100 2100

MAT (N) 2000

EDS (N) 800

Impact 5 J

Temperature Range -40º C to +70ºC

Min. Bending Radius 20 x ø Outer

SPECIFICATIONS

Span Max 80 m

Fibres Up to 24

Self-supporting Element Steel Messenger 4.0 mm

Strength Members Aramid Yarns

Outer Jacket Lineal High Density Polyethylene

Colour Black

Weight (Kg/Km) 185

ø Outer Diameter (mm) 16.0 x +7.0 ±0.5

MAT (N) 5700

EDS (N) 2250

Temperature Range -40º C to + 70º C

Min. Bending Radius 20 x ø Outer

Aerial loose tube

Environmental and Mechanical Tests according to EN 187000 and IEC 60794.Fibres Colours: Red, green, blue, yellow, grey, violet, brown, orange, white, pink, black and natural.Max.InducedVoltage=12KV

Aerial Installation Conditions (1)Wind Ice Span (m)(Km/h) (mm) 80m 120m 150m 200m100 0 100 135 195 2500 10 100 140 205 2700 15 60 80 115 15560 10 80 105 150 200

NESC Aerial Installation Conditions( (1) Span 80m 120m 150m 200mNESC Light 100 135 190 255NESC Medium 80 105 150 200

(1) Typical values for a 48 fibres cable.

Page 19: Optical fibre cables and optoelectronic converters - Policie

p.19

Aerial loose tube

Aerial loose tube

SPECIFICATIONS

Vano Máximo 80 m | 120 m | 150 m | 200 mFibres 4 6 8 12 16 24 32 36 48 64 72 96Fibres per Tube 2 2 2 2 4 4 8 6 8 8 12 12Total Tubes 6 6 6 6 6 6 6 6 6 8 6 8Inner Jacket PolyethyleneStrength Members Aramid YarnsOuter Jacket PolyethyleneColour BlackMAT (N) 80 m: 3000 120 m: 4000 150 m: 6000 200 m: 8000EDS (N) 80 m: 1200 80 m: 1600 80 m: 2400 80 m: 3200Impact 5JTemperature Range -40º C to +70º CMin. Bending Radius 20 x ø Outer

80 mWeight (Kg/Km) 111 113 115 120 116 120 133 121 139 175 141 177ø Outer 12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5 13.3 ± 0.5 12.4 ± 0.5 13.3 ± 0.5 15 ± 0.5 13.3 ± 0.5 15 ± 0.5

Maximum Length 3200 3200 3200 3200 3200 3200 2100 3200 2100 2100 2100 2100

120 mWeight (Kg/Km) 113 115 117 122 118 123 133 123 142 177 143 179ø Outer 12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5 13.3 ± 0.5 12.4 ± 0.5 13.3 ± 0.5 15 ± 0.5 13.3 ± 0.5 15 ± 0.5

Maximum Length 3200 3200 3200 3200 3200 3200 2100 3200 2100 2100 2100 2100

150 mWeight (Kg/Km) 118 120 123 127 123 128 141 128 147 182 148 184ø Outer 12.7 ± 0.5 12.7 ± 0.5 12.7 ± 0.5 12.7 ± 0.5 12.7 ± 0.5 12.7 ± 0.5 13.6 ± 0.5 12.7 ± 0.5 13.6 ± 0.5 15.3 ± 0.5 13.6 ± 0.5 15.3 ± 0.5

Maximum Length 3200 3200 3200 3200 3200 3200 2100 3200 2100 2100 2100 2100

200 mWeight (Kg/Km) 123 125 127 132 128 132 145 133 151 186 153 188ø Outer 12.8 ± 0.5 12.8 ± 0.5 12.8 ± 0.5 12.8 ± 0.5 12.8 ± 0.5 12.8 ± 0.5 13.7 ± 0.5 12.8 ± 0.5 13.7 ± 0.5 15.3 ± 0.5 13.7 ± 0.5 15.3 ± 0.5

Maximum Length 3200 3200 3200 3200 3200 3200 2100 3200 2100 2100 2100 2100

ADSS-50u

Sel

f-su

ppor

ted

Loo

se t

ubeCable Description

• Central Filler• Fibre Optics•Loosetube(jellyfilled)• Aramid• Ripcord•Outerjacket

Applications• Aerial Installations

Options• Ballistic Protection• Special Colour Code (TIA 598)

Advantages• Excellent mechanical resistance / Totally dielectric / Tough / Resistant / High density of fibres / Self-supported aerial applications.

Aerial Installation Conditions (1)Wind Ice Span(Km/h) (mm) (m)

100 0 900 10 800 15 4560 10 60

NESCAerial Installation Conditions( (1) SpanNESC Light 80NESC Medium 55

01

0403

05

02

06

01. CENTRAL FILLER02. FIBRE OPTICS03. LOOSE TUBE (JELLY FILLED)04. ARAMID05. RIPCORD06. OUTER JACKET

SPECIFICATIONS

Fibres 4 6 8 12 16 24 32 36 48 64 72 96

Fibres per Tube 2 2 2 2 4 4 8 6 8 8 12 12

Total Tubes 6 6 6 6 6 6 6 6 6 8 6 8

Strength Members Aramid Yarns

Outer Jacket Polyethylene

Colour Black

Weight (Kg/Km) 68 69 70 73 71 73 87 74 92 119 94 121

ø Outer (mm) 9.7±0.5 9.7±0.5 9.7±0.5 9.7±0.5 9.7±0.5 9.7±0.5 10.9±0.5 9.7±0.5 10.9±0.5 12.4±0.5 10.9±0.5 12.4±0.5

Maximum Length (mm) 3200 3200 3200 3200 3200 3200 2100 3200 2100 2100 2100 2100

MAT (N) 2000

EDS (N) 800

Impact 5 J

Temperature Range -40º C to +70ºC

Min. Bending Radius 20 x ø Outer

CAM-Figura 8S

elf-

supp

orte

dCable Description•Fibre Optic•Loosetube(jellyfilled)•Aramid•Steel Messenger•Outer Jacket

Applications•Aerial Installations

Options•Anti-Tracking Jacket

Advantages•Excellent mechanical resistance / Tough / Resistant / Self-supported aerial applications.

01. FIBRE OPTIC02. LOOSE TUBE (JELLY FILLED)03. ARAMID04. STEEL MESSENGER05. OUTER JACKET

02

01

03

05 04

SPECIFICATIONS

Span Max 80 m

Fibres Up to 24

Self-supporting Element Steel Messenger 4.0 mm

Strength Members Aramid Yarns

Outer Jacket Lineal High Density Polyethylene

Colour Black

Weight (Kg/Km) 185

ø Outer Diameter (mm) 16.0 x +7.0 ±0.5

MAT (N) 5700

EDS (N) 2250

Temperature Range -40º C to + 70º C

Min. Bending Radius 20 x ø Outer

(1) Typical values for a 48 fibres cable.

Environmental and Mechanical Tests according to EN 187000 and IEC 60794.Fibres Colours: Red, green, blue, yellow, grey, violet, brown, orange, white, pink, black and natural.Max.InducedVoltage=12KV

Aerial Installation Conditions (1)Wind Ice Span (Km/h) (mm) (m)

100 0 1100 10 1850 15 10560 10 105

NESC Aerial Installation Conditions( (1) SpanNESC Light 115NESC Medium 105

(1) Typical values for a 48 fibres cable..

Environmental and mechanical tests according to EN 187000 and IEC 60794.Fibres Colour: Red - Green - Blue - Yellow - Grey - Violet - Brown - Orange - White - Pink - Black - Turquoise - Red 1 stripe - Green 1 stripe - Blue 1 stripe - Yellow 1 stripe - White 1 stripe - Violet 1 stripe - Orange 1 stripe - Natural 1 stripe - Grey 1 stripe - Brown 1 stripe - Pink 1 stripe - Turquoise 1 stripe.

Page 20: Optical fibre cables and optoelectronic converters - Policie

p.20

CAS - S1

Indo

or

01. TIGHT BUFFERED FIBRE02. ARAMID03. OUTER JACKET

Cable description•TightBufferedFibre•Aramid•OuterJacket

Fire Resistance•Flameretardant•Halogenfree•Lowsmokeemission

Applications•Indoor•Pigtailandjumperconnections•Directconnectiontoterminal equipments FTTx

Options•Fibretype•Specialcolourcode•Jacketcolour•Specialpackaging“ReelinaBox”1

Advantages•Flexible/Dielectric/Direct connectorization.

SPECIFICATIONS

Type S100 S105 S110 S115

Fibre Count 1 2 1 2

Buffer Diameter (mm) 0,9 0,6 0,9 0,9

Fibre Type G.657 A

Strength Members Aramid Yarns

Outer Jacket LSZH2

Jacket Colour Ivory

Weight (Kg/Km) 7 7 14 14

ø Outer (mm) 2.9 ± 0.15 2.9 ± 0.15 3.6 ± 0.15 3.6 ± 0.15

Tensile Load Permanent / Instal. (N) 200 / 350 200 / 350 200 / 350 200 / 350

Crush (N/100mm) 500 500 700 700

Temperature Range -10ºC to + 70ºC

Min. Bending Radius (mm) 5 x ø Outer

CAS FLAT - F1

Indo

or

Cable description•FibreOptics•FRP•OuterJacket

Fire Resistance•Halogenfree•Flameretardant•Lowsmokeemission

Applications•Indoor•FTTx

Advantages•Lightweight/Resistant/Totally dielectric / Reduced diameter

SPECIFICATIONS

Type F100

Fibre count 2

Fibre Type G.657 A

Identification Colour Code1

Strength Members FRP

Outer Jacket LSZH1

Jacket Colour Ivory

Weight (Kg/Km) 7.6

ø Outer (mm) 2.0 x 3.0 ± 0.20

Max. Tensile Load 100

Crush 1000 N / 10 cm

Temperature Range -30º C to +70ºC

SPECIFICATIONS

Type R100 R105

Fibre Count 1 2

Buffer Diameter (mm) 0.9 0.6

Fibre Type G.657A

Strength Members Aramid Yarns

Inner Jacket LSZH2

Outer Jacket LSZH2

Jacket Colour Ivory

Weight (Kg/Km) 21

ø Outer (mm) 4.6 ±0.2

Tensile Load Permanent / Instal. (N) 350 / 650

Crush (N/100mm) 800

Temperature Range -10ºC to +70ºC

Min. Bending Radius (mm) 5 x ø Outer

SPECIFICATIONS

Type V100

Fibre Count 2 4 6 8 12

Fibre Type G.657A

Strength Members Aramid Yarns

Outer Jacket Thermoplastic LSZH2

Jacket Colour Ivory

Weight (Kg/Km) 23 26 36 43 56

ø Outer (mm) 4.9 ±0.3 5.3 ±0.3 6.1 ±0.3 6.7 ±0.3 7.7 ±0.3

Tensile Load Permanent / Instal. (N) 400 / 650 400 / 650 400 / 650 550 / 1000 550 / 1000

Crush (N/100mm) 1000 1000 1000 1200 1200

Temperature Range -10º C to +70ºC

Min. Bending Radius (mm) 5 x ø Outer

Drop cable

Drop cable

01. FIBRE OPTICS02. FRP03. OUTER JACKET

StandardsEnvironmental and mechanical tests according to EN187000 and IEC60794.Fire tests : UNE-EN 50265 (IEC 60332-1) / UNE-EN 50267 (IEC 60754-1/2) / UNE-EN 61034 (IEC 61034-1/2).Fibres colour code : 1 FO: Natural / 2 FO: Red – Green.1 Consult available lengths.2 LSZH – Halogen free, low smoke emission, flame retardant compound.

StandardsEnvironmental and mechanical tests according to EN 187000 and IEC 60794.Fibres colour code: Red – Green.1LSZH: Halogen free, low smoke, flame retardant compound.

Page 21: Optical fibre cables and optoelectronic converters - Policie

p.21

SPECIFICATIONS

Type S100 S105 S110 S115

Fibre Count 1 2 1 2

Buffer Diameter (mm) 0,9 0,6 0,9 0,9

Fibre Type G.657 A

Strength Members Aramid Yarns

Outer Jacket LSZH2

Jacket Colour Ivory

Weight (Kg/Km) 7 7 14 14

ø Outer (mm) 2.9 ± 0.15 2.9 ± 0.15 3.6 ± 0.15 3.6 ± 0.15

Tensile Load Permanent / Instal. (N) 200 / 350 200 / 350 200 / 350 200 / 350

Crush (N/100mm) 500 500 700 700

Temperature Range -10ºC to + 70ºC

Min. Bending Radius (mm) 5 x ø Outer

SPECIFICATIONS

Type F100

Fibre count 2

Fibre Type G.657 A

Identification Colour Code1

Strength Members FRP

Outer Jacket LSZH1

Jacket Colour Ivory

Weight (Kg/Km) 7.6

ø Outer (mm) 2.0 x 3.0 ± 0.20

Max. Tensile Load 100

Crush 1000 N / 10 cm

Temperature Range -30º C to +70ºC

CAR / R1

Indo

or

Cable description•Tight Buffered Fibre• Aramid•Inner Jacket•Aramid• Outer Jacket

Fire Resistance•Flame retardant•Halogen free•Low smoke emission

Applications•Indoor•Drop cable•Pigtailandjumperconnections•Direct connection to terminal equipments FTTx

Options•Fibre type•Special colour code•Jacket colour•Special packaging “Reel in a Box” 1

Advantages•Flexible / Resilient / Dielectric / Reinforced / Direct connectorization.

SPECIFICATIONS

Type R100 R105

Fibre Count 1 2

Buffer Diameter (mm) 0.9 0.6

Fibre Type G.657A

Strength Members Aramid Yarns

Inner Jacket LSZH2

Outer Jacket LSZH2

Jacket Colour Ivory

Weight (Kg/Km) 21

ø Outer (mm) 4.6 ±0.2

Tensile Load Permanent / Instal. (N) 350 / 650

Crush (N/100mm) 800

Temperature Range -10ºC to +70ºC

Min. Bending Radius (mm) 5 x ø Outer

01. TIGHT BUFFERED FIBRE02. ARAMID03. INNER JACKET04. ARAMID05. OUTER JACKET

CDV / V1In

door

Cable description•Tight Buffered Fibre (0.9 mm)•Aramid Yarns•Outer Jacket

Fire Resistance•Flame / Fire retardant•Halogen free•Low smoke emission

Applications•Indoor•Drop cable (vertical)•Direct connectorizations in FTTx applications

Options•Fibre type•Special colour code•Outerjacketcolour•Special packaging “Reel in a Box” 1

Advantages•Compact / Lightweight / Flexible / Easy to strip (gel free) / Totally dielectric / Direct connectorization / Saves installation costs.

01. TIGHT BUFFERED FIBRE02. ARAMID YARNS03. OUTER JACKET

03

02

01

SPECIFICATIONS

Type V100

Fibre Count 2 4 6 8 12

Fibre Type G.657A

Strength Members Aramid Yarns

Outer Jacket Thermoplastic LSZH2

Jacket Colour Ivory

Weight (Kg/Km) 23 26 36 43 56

ø Outer (mm) 4.9 ±0.3 5.3 ±0.3 6.1 ±0.3 6.7 ±0.3 7.7 ±0.3

Tensile Load Permanent / Instal. (N) 400 / 650 400 / 650 400 / 650 550 / 1000 550 / 1000

Crush (N/100mm) 1000 1000 1000 1200 1200

Temperature Range -10º C to +70ºC

Min. Bending Radius (mm) 5 x ø Outer

Reinforced drop cable

Distribution cable

StandardsEnvironmental and mechanical tests according to EN187000 and IEC60794.Fire tests : UNE-EN 50265 (IEC 60332-1) / UNE-EN 50267 (IEC 60754-1/2) / UNE-EN 61034 (IEC 61034-1/2).Fibres colour code : 1 FO: Natural / 2 FO: Red – Green.1 Consult available lengths.2 LSZH – Halogen free, low smoke emission, flame retardant compound.

StandardsMechanical and environmental tests according to EN187000, IEC60794.Fire tests : UNE-EN 50265 (IEC 60332-1) / UNE-EN 50267-1/2 (IEC60754-1/2) / UNE-EN 61034-1/2 (IEC 61034-1/2).Fibres colour code : 1 FO: Natural / 2 FO: Red – Green.1 Consult available lengths.2 LSZH – Halogen free, low smoke emission, flame retardant compound.

StandardsMechanical and environmental tests acc/ EN 187000, IEC60794.Fire tests: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267 (IEC 60754-2-1/-2) / UNE-EN 61034 (IEC 61034-2-1/-2).Fibres colour code: red – green – grey – yellow – blue – natural – white – brown – violet – orange – pink – black.1 Consult available lengths.2 LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.

Page 22: Optical fibre cables and optoelectronic converters - Policie

p.22

CAR - R2

Out

door

01. TIGHT BUFFERED FIBRE02. ARAMID03. OUTER JACKET

Cable description•TightBufferedFibre•Aramid•OuterJacket

Applications•Outdoor•Self-supporteddropcableFTTx

Options•Fibretype•Outerjacketcolour

Advantages•Excellentmechanicalresistance/ Dielectric / Tough / Resistant.

SPECIFICATIONS

Type R200 R205

Fibre Count 1 2

Buffer Diameter (mm) 0.9 0.6

Fibre Type G.657A

Self-supporting Element Aramid Yarns

Outer Jacket LSZH1

Jacket Colour Black

Weight (Kg/Km) 13

ø Outer (mm) 2.5 x 5.2

Tensile Load Permanent / Instal. (N) 250 / 400

Crush (N/100mm) 600

Impact (Nm/100 impacts) 1.5

Temperature Range -20ºC to +80ºC

ADSS FLAT - F2

Out

door

Cable description•FibreOptics•FRP•OuterJacket

Applications•Outdoor•Self-supporteddropcableFTTx

Advantages•Excellentmechanicalresistance/ Dielectric / Tough / Resistant / Aerial drop applications.

SPECIFICATIONS

Type F200

Fibre Count Up to 12

Fibre Type G652D / G657A

Fibres Identification Colour Code1

Strength Members FRP

Outer Jacket Black PE

Weight (Kg/Km) 31 Kg/Km

Ø Outer 3.8 mm x 7.0 mm ± 0.20

Max. Tensile Load 1200 N

Min. Bend Radius Static / Dinamic 20 x Ø Outer / 30 x Ø Outer

Temperature Range Opera-tion / Installation -40ºC to + 70ºC

SPECIFICATIONS

Fibre Count 2 .. 12

Strength Members Aramid Yarns

Outer Jacket Thermoplastic LSZH1

Jacket Colour Black

Weight (Kg/Km) 10

ø Outer (mm) 3.5 ± 0.1

Tensile Load (N) 80

Temperature Range -30 ºC to +70 ºC

Min. Bending Radius (mm) 20 x ø Outer

SPECIFICATIONS

Fibre Count 24 36 48 72 96 144Total Tubes 6 6 6 6 8 12Active Tubes 2 3 4 6 8 12Fibres per Tube 12Outer Jacket PolyethyleneColour BlackWeight (Kg/Km) 29 29 29 29 42 72Ø Outer (mm) 5.7 ± 0.2 5.7 ± 0.2 5.7 ± 0.2 5.7 ± 0.2 6.6 ± 0.2 8.6 ± 0.2

Tensile Load (N) 500 500 500 500 1200 1500Temperature Range -40 ºC to +70 ºCMin. Bending radius 20 x ø Outer

Aerial cable

Self-supported cable

01. FIBRE OPTICS02. FRP03. OUTER JACKET

StandardsMechanical and environmental tests according to EN187000, IEC60794.Fire tests : UNE-EN 50265 (IEC 60332-1) / UNE-EN 50267-1/2 (IEC60754-1/2) / UNE-EN 61034-1/2 (IEC 61034-1/2).Fibres colour code : 1 FO: Natural / 2 FO: Red – Green.1 LSZH: Halogen free, low smoke emission, flame retardant compound.

StandardsMechanical and environmental tests according to EN187000, IEC60794-1-2.1 Fibres colour code: Red – Green – Blue – Yellow – Grey – Violet – Brown – Orange – White – Pink – Black – Natural.

Page 23: Optical fibre cables and optoelectronic converters - Policie

p.23

SPECIFICATIONS

Type R200 R205

Fibre Count 1 2

Buffer Diameter (mm) 0.9 0.6

Fibre Type G.657A

Self-supporting Element Aramid Yarns

Outer Jacket LSZH1

Jacket Colour Black

Weight (Kg/Km) 13

ø Outer (mm) 2.5 x 5.2

Tensile Load Permanent / Instal. (N) 250 / 400

Crush (N/100mm) 600

Impact (Nm/100 impacts) 1.5

Temperature Range -20ºC to +80ºC

SPECIFICATIONS

Type F200

Fibre Count Up to 12

Fibre Type G652D / G657A

Fibres Identification Colour Code1

Strength Members FRP

Outer Jacket Black PE

Weight (Kg/Km) 31 Kg/Km

Ø Outer 3.8 mm x 7.0 mm ± 0.20

Max. Tensile Load 1200 N

Min. Bend Radius Static / Dinamic 20 x Ø Outer / 30 x Ø Outer

Temperature Range Opera-tion / Installation -40ºC to + 70ºC

ABD - 01

Indo

or

Cable description•Fibre Optics•Secondary Loose Tube•Aramid•Outer Jacket

Fire Resistance•Flame retardant•Halogen free•Low smoke emission

Applications •Indoor

Advantages•Compact / Tough / Resistant / Totally Dielectric / Suitable for “blow air” systems.

01. FIBRE OPTICS02. SECONDARY LOOSE TUBE03. ARAMID04. OUTER JACKET

SPECIFICATIONS

Fibre Count 2 .. 12

Strength Members Aramid Yarns

Outer Jacket Thermoplastic LSZH1

Jacket Colour Black

Weight (Kg/Km) 10

ø Outer (mm) 3.5 ± 0.1

Tensile Load (N) 80

Temperature Range -30 ºC to +70 ºC

Min. Bending Radius (mm) 20 x ø Outer

ABDO

utdo

or

Cable description•Central Element (GRP)•Fibre Optics•Loose Tubes (Jelly Filled)•Outer Jacket

Applications •Outdoor

Options•LSZH Jacket•PA12 Jacket

Advantages•Compact / Tough / Resistant / Totally Dielectric / Excellent resistance to friction / Suitable for “blow air” systems.

01. CENTRAL ELEMENT (GRP)02. FIBRE OPTICS03. LOOSE TUBES (JELLY FILLED)04. OUTER JACKET

SPECIFICATIONS

Fibre Count 24 36 48 72 96 144Total Tubes 6 6 6 6 8 12Active Tubes 2 3 4 6 8 12Fibres per Tube 12Outer Jacket PolyethyleneColour BlackWeight (Kg/Km) 29 29 29 29 42 72Ø Outer (mm) 5.7 ± 0.2 5.7 ± 0.2 5.7 ± 0.2 5.7 ± 0.2 6.6 ± 0.2 8.6 ± 0.2

Tensile Load (N) 500 500 500 500 1200 1500Temperature Range -40 ºC to +70 ºCMin. Bending radius 20 x ø Outer

Loose tube cables

Loose tube cables

0403

02

01

StandardsMechanical and environmental tests according to EN187000, IEC60794.Fire tests : UNE-EN 50265 (IEC 60332-1) / UNE-EN 50267-1/2 (IEC60754-1/2) / UNE-EN 61034-1/2 (IEC 61034-1/2).Fibres colour code : 1 FO: Natural / 2 FO: Red – Green.1 LSZH: Halogen free, low smoke emission, flame retardant compound.

StandardsEnvironmental and Mechanical tests according to EN 187000 and CEI 60794.Fibres colour code: red, green, blue, yellow, grey, violet, brown, orange, white, pink, black, natural.

StandardsEnvironmental and Mechanical tests according to EN 187000 and CEI 60794.Fibres colour code: red, green, blue, yellow, grey, violet, brown, orange, white, pink, black, natural.

Page 24: Optical fibre cables and optoelectronic converters - Policie

p.24

Kit estandard

1 o 2 Pig-tail FO SM G657 – SC/APC +1 o 2 Adaptors – SC/APC +1 o 2 Mechanical splices +1 o 2 Mechanical splices +Termination box

SCPSubscriber connection point

Subscriber connection point 01.Base02.Top Modularity•Supportjoint(till4units)•Cableaccesspunching•Rearaccesscable•Slide

Applications•Intothebuildings•SubscriberCable(CAS,CAR,CDV)•DirectConnectorizationinFTTxapplications

Options•From1to4SC/APCadaptors•SuppliedwithPre-assembledCable

Benefits•CompactandSmallformat.•Lightweight•Easyinstallation•Moderndesign•Installationcostsavings

It will be possible to supply this termination box in 25, 40 or 50 m. with pre-assembled cable in SC/APC adaptors, from 1 to 4 plugs. This means a reduction in time and cost during the installation.

Kit FTTx Line

Dimensiones mm

A Large 130

B Width 75

C Height 37

D Height 18

C

D

B

A

Page 25: Optical fibre cables and optoelectronic converters - Policie

p.25

SCPSubscriber connection point

Cable BOX Reel in a box:• Plasticstructure• Spool• Cartonbox Applications• Intothebuildings• Subscribercable(CAS,CAR,…)• InternalDistributioncable(CDV)

Options• Subscribercable:305/500/1.000m• InternalDistributioncable:150/200/250m

Benefits• Linealunwinding/Compact/Lightweight/Easy installation / Installation costs savings

Dimensions

A Height 350 mm

B Width 350 mm

C Depth 350 mm

0103 02

01. Plastic structure02. Spool03. Carton box

A

B

C

Characteristics

CABLE TYPE ø mm Box 305 Box 500 Box 1000

CAS (S100, S105) 2,9 ± 0,15 4 kg 5,5 kg 9 kg

CAS (S100, S105) 3,6 ± 0,2 6 kg 9 kg 16 kg

CAS-FLAT (F100) 2×3 ± 0,2 4 kg 6 kg 9,5 kg

CAR (R100, R105) 4,6 ± 0,2 9,5 kg 14,5 kg

CAR (R200, R205) 2,5×5,2 ± 0,2 6 kg 8,5 kg

Characteristics

CABLE TYPE ø mm Box 150 Box 200 Box 250

CDV (V100) 4 5,5 ± 0,3 8 kg 9 kg

CDV (V100) 6 6,2 ± 0,3 8 kg 9,5 kg 11,5 kg

CDV (V100) 8 6,9 ± 0,3 9 kg 11 kg 13,5 kg

CDV (V100) 12 7,9 ± 0,3 11 kg 14 kg

Page 26: Optical fibre cables and optoelectronic converters - Policie

p.26

SolutionFTTx

12

3

4

5

Page 27: Optical fibre cables and optoelectronic converters - Policie

p.27

5

5

1

4

1

TRUNK Cable (1): Could be used to any type of cable depending on the environment:

Conventional method: PKP, PSP, DP, DSP, NEXO o TENAXBlow microducts: ABD o HDAerial installation: ADSS, …

DROP Cable: Could be applying any type of cable (usually till 24fo), it has his origin point in a trunk cable and his destination in the building or cabinet in the curb (usually in the distribution boxes):

Outdoor installation (2): CAR R200, ADSS F200, ABD-01, …Indoor installation (3): CAR R100, CAR R105 o CDV (+ 2 viviendas)Subscriber installation (4): CAS S100 – S115 (bajo tubo) CAS FLAT (bajo tubo o pared) CAR R100 o R105 (bajo tubo o pared)Subscriber connection point (5): Roseta PCU

Page 28: Optical fibre cables and optoelectronic converters - Policie

p.28

MULTIMODE OPTICAL FIBRE 62,5 / 125 Optical Comunications

Geometrical and mechanical characteristics

Values

Core diameter 62.5 ± 2.5 μm

Core non-circularity ≤ 6%

Core / Cladding concentricity error ≤ 1.5 μm

Cladding diameter 125+/-2 μm

Cladding non-circularity ≤ 1%

Primary coating diameter 245+/-10 μm

Coating non-circularity ≤ 6%

Coating concentricity error ≤ 12.5 μm

Proof Test ≥ 8.8 N / ≥ 1 % / ≥ 100 Kpsi

Geometrical and mechanical characteristics Values

Core diameter 50 ± 2.0 μm

Core non-circularity ≤ 5 %

Core / Cladding concentricity error ≤ 1 μm

Cladding diameter 125 ± 1.0 μm

Cladding non-circularity ≤ 0.7 %

Primary coating diameter 242 ± 5 μm

Coating non-circularity ≤ 5 %

Coating concentricity error ≤ 12.5 μm

Proof Test ≥ 8.8 N / ≥ 1 % / ≥ 100 Kpsi

Geometrical and mechanical characteristics according to IEC 60793-2-10.

Graded-Index multimode optical fibres 62,5/125 micron. The fibres are designed for its use at the wavelengths of 850 nm and 1300 nm. These fibres are suitable for use in premises wiring applications, like Local Area Networks (LAN) with video, data and voice using LED, VCSEL or Laser Fabry Perot sources. These fibres comply with IEC 60793-2-10 A1b.

Graded-Index multimode optical fibres 50/125 micron. The fibres are designed for use at 850 and 1300 nm. These fibres are suitable for use inpremises wiring applications, like Local Area Net-works (LAN) with video, data and voice using LED, VCSEL or Laser Fabry Perot sources.These fibres comply or exceed the standards IEC 60793-2-10 A1a.1, A1a.2, A1a.3, TIA/EIA-492AAAB, TIA/EIA-492AAAC-A, TIA/EIA-492AAAD, Telcordia GR-20-CORE, GR-409-CORE, TIA/EIA 568C.

Geometrical and mechanical characteristics according to IEC 60793-2-10.

Optical properties according to IEC 60793-2, ISO/IEC 11801, EN 50173, TIA/EIA-492AAAB, TIA/EIA-492AAAC-A, TIA/EIA-492AAAD, Telcordia GR-20-CORE, GR-409-CORE, TIA/EIA 568C.

Optical characteristics OM1 OM2 Giga

Attenuation Coefficient (db/Km)

850 nm ≤ 3.0 ≤ 3.0 ≤ 3.0

1300 nm ≤ 0.7 ≤ 0.7 ≤ 0.7

Bandwidth (MHz x Km)

850 nm ≥ 200 ≥ 500 ≥ 200

1300 nm ≥ 500 ≥ 500 ≥ 500

Link Distance (m)1000Base-SX 275 550 500

1000Base-LX 550 550 1000

Numerical Aperture 0.275 ± 0.015

Group Index of Refraction

850 nm 1496

1300 nm 1491

Optical properties according to IEC 60793-2-10, ISO/IEC 11801, EN 50173, ANSI/TIA/EIA-492AAAA-A and ANSI/EIA/TIA 568-C.

MULTIMODE OPTICAL FIBRE 50 / 125 Optical Comunications

Optical characteristics OM1 OM2 OM2 XL OM3 SL OM3 OM4 Giga

Attenuation Coefficient (db/Km)850 nm ≤ 2.5 ≤ 2.5 ≤ 2.5 ≤ 2.5 ≤ 2.5 ≤ 2.5 ≤ 2.5

1300 nm ≤ 0.7 ≤ 0.7 ≤ 0.7 ≤ 0.7 ≤ 0.7 ≤ 0.7 ≤ 0.7

Bandwidth (MHz x Km)

850 nm ≥ 200 ≥ 500 ≥ 600 ≥ 700 ≥ 1500 ≥ 3500 ≥ 600

1300 nm ≥ 500 ≥ 500 ≥ 1200 ≥ 500 ≥ 500 ≥ 500 ≥ 1200

Link Distance (m)

1000Base - SX 275 550 550 800 900 1100 750

1000Base - LX 550 550 550 550 550 550 2000

1000Base - SX 33 82 82 150 300 550 110

Numerical Aperture 0.200 ± 0.015

Group Index of Refraction850 nm 1.482

1300 nm 1.477

Page 29: Optical fibre cables and optoelectronic converters - Policie

p.29

Optical properties according to IEC 60793-2, ISO/IEC 11801, EN 50173, TIA/EIA-492AAAB, TIA/EIA-492AAAC-A, TIA/EIA-492AAAD, Telcordia GR-20-CORE, GR-409-CORE, TIA/EIA 568C.

Optical properties according to IEC 60793-2-10, ISO/IEC 11801, EN 50173, ANSI/TIA/EIA-492AAAA-A and ANSI/EIA/TIA 568-C.

Step index singlemode optical fibres. G652 fibres provide optimum performance in the 1310 nm wavelength. They can be used onmetropolitan and access networks, CATV and premises applications in telecom.These fibres comply or exceed the standards IEC 60793-2-50, ITU-T G.652.B, G.652.D, Telcordia GR-20-CORE, ANSI/ICEA S-87-640, RUS 7CFR 1755.900, ANSI/TIA/EIA-492CAAA.

Low macrobending sensitive fibre (G657) provides high resistance to additional losses due to macrobending. Ideal for cable mounting inside buildings, patchcords and/or interconnection cables. It offers significant added value in Fibre-to-the-Home accesss networks.

The fibre fully comply with or exceeds the IEC 60793-2-50, ITU G.652.D, G.657.A&B, Telcordia GR-20-CORE, ANSI/IECA S-87-640.

Characteristics according to ITU-T G.652.D, G.657A, G.657B, IEC 60793-2-50, Telcordia GR-20-CORE and ANSI/ICEA S-87-640.Important noticeAt present, G657 fibres are not recognized by some splicing machines. Check your machine before use it or ask your local distributor.

SINGLEMODE OPTICAL FIBRE SMF G.652B / G.652D / G.655 Optical Comunications

SINGLEMODE OPTICAL FIBRE SMF - G.657

Optical characteristics G.657.A G.657.B

Attenuation with Bending(1550 nm)

1 turn / Mandrel 10mm10 turns / Mandrel 15mm

≤ 0.75≤ 0.25

≤ 0.10≤ 0.03

Mode Field Diameter(μm)

1310 nm1550 nm

9.0 ± 0.4

10.1 ± 0.58.5 – 9.3

9.4 – 10.4

Attenuation Coefficient(dB/Km)

1310 nm1383 nm1460 nm1550 nm1625 nm

≤ 0.35≤ 0.35≤ 0.25≤ 0.21≤ 0.23

Chomatic Dispersion Coefficient(ps/nm.Km)

1285 – 1330 nm1550 nm1625 nm

≤ |3|≤ 18≤ 22

Zero Dispersion Wavelength (nm) 1300 – 1322 1300 – 1324Zero Dispersion Slope(ps / nm2 Km) ≤ 0.090 ≤ 0.092Cable Cutt-Off Wavelength (nm) ≤ 1260PMD (ps / (ps/√Km) 1550 nm ≤ 0.1

Geometrical and mechanical characteristics

G.657.A G.657.B

Cladding Diameter 125 ± 0.7 μmCore / Cladding Concentricity ≤ 0.5 μmCladding Non-Circularity ≤ 0.7 %Primary Coating Diameter 242 ± 0.7 μmCoating / Cladding Concentricity ≤ 12 μm ≤ 10 μmCoating Non-Circularity ≤ 5 %Proof Test ≥ 8.8 N / ≥ 1 % / ≥ 100 Kpsi

Geometrical and mechanical characteristics

G.652.B G.652.D G.655

Cladding Diameter 125 ± 1.0 μm 125 ± 0.7 μm 125 ± 1 μmCore / Cladding Concentricity ≤ 0.6 μm ≤ 0.5 μm ≤ 0.6 μmCladding Non-Circularity ≤ 1.0 % ≤ 0.7 % ≤ 1.0 %Primary Coating Diameter 242 ± 7 μmCoating / Cladding Concentricity ≤ 12 μmCoating Non-Circularity ≤ 7 % ≤ 5 %Proof Test ≥ 8.8 N / ≥ 1 % / ≥ 100 Kpsi

Characteristics according to ITU-T G.652, IEC 60793-2-50, ISO/IEC 11801, EN 50173, Telcordia GR-20-CORE, ANSI/ICEAS-87-640, RUS 7CFR 1755.900, ANSI/TIA/EIA-492CAAA.

Optical characteristics G.652.B G.652 D G.655

Mode Field Diameter(μm)

1310 nm1550 nm

9.0 ± 0.410.1 ± 0.5

9.0 ± 0.410.1 ± 0.5

-----9.2 ± 0.5

Attenuation Coefficient(dB / Km)

1310 nm1383 nm1460 nm1550 nm1625 nm

≤ 0,35 ≤ 1,0-----

≤ 0,23≤ 0,24

≤ 0,35 ≤ 0,35 ≤ 0,25 ≤ 0,22≤ 0,23

≤ 0,40 ≤ 1,00

-----≤ 0,25≤ 0,28

Chomatic Dispersion Coefficient(ps / nm.Km)

1310 nm1530 - 1565 nm1285 - 1330 nm1565 - 1625 nm1550 nm1625 nm

----------≤ 3-----≤ 18≤ 22

----------≤ 3-----≤ 18≤ 22

-65.5 to 10 -10 to -3

7.5 to 13.88

12Zero Dispersion Wavelength (nm) 1300 -1322 1300 -1322 ≤ 1440Zero Dispersion Slope (ps / nm2 Km) ≤ 0,092 ≤ 0,090 ≤ 0,052

Group Index of Refraction1310 nm1550 nm

14671468

14671468

1.46821.4683

Cable Cutt-Off Wavelength (nm) Cabling ≤ 1260 ≤ 1260 ≤ 1300PMD (ps / √Km) 1550 nm ≤ 0,1 ≤ 0,1 ≤ 0,2

Page 30: Optical fibre cables and optoelectronic converters - Policie

p.30

VM1 - VIDEO

Features•Multimodeopticalfibre•Wavelength850nmand1300nm•ModularUnits:TypeS,TypeM,Mini, Micro and rack cards•Configurableforshortandlong distances•Opticalconnectors:ST(1) Power / temperature / size•Temperature=0º÷+50ºC•Humidity=10%÷90%•12Vdc/250mA•ModularUnits: -TypeS=105x95x32mm -TypeM=179x127x32mm -TypeMini=67x47x25mm -TypeMicro=61x25x23mm

Video signal•I/OImpedance=75Ω•Bandwidth=10MHz•DifferentialGain<2%•DifferentialPhase<2º•I/OVideoconnector=BNC•AGCIncludedinthereceivers (Models: VM107)

Accesories (not included)•ModularUnits(PowerSupplies) -TypeS,M,MiniandMicro=PS150•RackCards -CardCage3U(Rack19”)=PR100

(1) For other optical connectors, consult us.

Specifications Available models

Reference Description Format Nº Fibres Maximumattenuation (3)

Wavelength

VM101-TB1 1 Tx Vídeo Modular Type S 1

14 dB 850 nm

VM101-TR1 2 Tx Vídeo Rack Rack 2

VM102-TB1 2 Tx Vídeo Modular Type M 2

VM101-RB1 1 Rx Vídeo Modular Type S 1

VM101-RR1 2 Rx Vídeo Rack Rack 2

VM101-TB2 1 Tx Vídeo Modular Type S 1

14 dB 1300 nm

VM101-TR2 2 Tx Vídeo Rack Rack 2

VM102-TB2 2 Tx Vídeo Modular Type M 2

VM101-RB2 1 Rx Vídeo Modular Type S 1

VM101-RR2 2 Rx Vídeo Rack Rack 2

VM104-TB1 1 Tx Vídeo Mini Mini 1 12 dB 850 nm

VM104-TB2 1 Tx Vídeo Mini Mini 1 12 dB 1300 nm

VM105-TB1 1 Tx Vídeo Micro Micro 1 12 dB 850 nm

VM105-TB2 1 Tx Vídeo Micro Micro 1 12 dB 1300 nm

(3) Maximum attenuation at 62.5/125. For 50/125 reduce optical budget by 3dB.TypeS=105x95x32mm/TypeM=179x127x32mm/TypeMini=67x47x25mm/TypeMicro=61x25x23mm

Other equipmentsVM7 - Video + RS-232

OM1-Contacts ON/OFF

Accessories

MCM - MCS - Ethernet

Optoelectronic converters Multimode fibreThe OPTRAL Series VM1 allows the transmission of one standard video signal over multimode optical fibre. One transmitter and one receiver using one single fibre form the basic system. The receivers in modular and rack format are available with Automatic Gain Control (AGC) and do not require any kind of adjustments(Models: VM107). All the models comply with the requirements according to the Electromagnetic Compatibility and LowTension Standards ( Marking).

Page 31: Optical fibre cables and optoelectronic converters - Policie

p.31

Optoelectronic converters Multimode fibre

The OPTRAL Series DM5 allows the transmission and reception of RS232, RS422 andRS485 data signals over

multimode optical fibre. The basic system consists of twotransceiver and two fibre optics for each communication

channel with speeds up to 115 Kbs.The communication protocol: RS232, RS422, RS485-2H (2 Wires Half

Duplex) and RS4854H (4 Wires Full Duplex), can be selected by a switch.

All the models comply with the requirements according to the Electromagnetic Compatibility and Low Tension

Standards ( Marking).

Features•MultimodeOpticalFibre•Wavelength850nmand1300nm•ModularUnits,RackCardsandDINrail•Configurableforshortandlongdistances•Opticalconnectors:ST(1)

(1)For other optical connectors consult us

Power / temperature / size•Temperature=0º÷+50ºC•Humidity=10%÷90%•Power: - 12 Vdc / 250 mA for Rack Cards - 12 to 24Vdc for Modular Units and DIN •Size -DINrail=45x70x121mm -TypeS=105x95x32mm -TypeRack=1SlotRack

Communication•Datarate≤ 115 Kbs•BitErrorRate≤ 10-9•Operatingmode=Asynchronous/Half-FullDuplex•Selectionofcommunication:SWITCH•Dataconnector=ScrewTerminalCI(7pin)

Accesories (not included)•ModularUnits(PowerSupplies) -TypeS=ModelPS150 -DINrail=ModelPS150•RackCards -CardCage3U(Rack19”)=PR100

Specifications Available models

Reference Description Format Nº Fibres Maximumattenuation (3)

Wavelength

VM101-TB1 1 Tx Vídeo Modular Type S 1

14 dB 850 nm

VM101-TR1 2 Tx Vídeo Rack Rack 2

VM102-TB1 2 Tx Vídeo Modular Type M 2

VM101-RB1 1 Rx Vídeo Modular Type S 1

VM101-RR1 2 Rx Vídeo Rack Rack 2

VM101-TB2 1 Tx Vídeo Modular Type S 1

14 dB 1300 nm

VM101-TR2 2 Tx Vídeo Rack Rack 2

VM102-TB2 2 Tx Vídeo Modular Type M 2

VM101-RB2 1 Rx Vídeo Modular Type S 1

VM101-RR2 2 Rx Vídeo Rack Rack 2

VM104-TB1 1 Tx Vídeo Mini Mini 1 12 dB 850 nm

VM104-TB2 1 Tx Vídeo Mini Mini 1 12 dB 1300 nm

VM105-TB1 1 Tx Vídeo Micro Micro 1 12 dB 850 nm

VM105-TB2 1 Tx Vídeo Micro Micro 1 12 dB 1300 nm

(3) Maximum attenuation at 62.5/125. For 50/125 reduce optical budget by 3dB.TypeS=105x95x32mm/TypeM=179x127x32mm/TypeMini=67x47x25mm/TypeMicro=61x25x23mm

DM5 - DATARS232, RS422 and RS485

Specifications Available models

Reference Description Format Nº Fibres Maximumattenuation (2)

Wavelength

DM501-XD1Transceiver

RS232, RS422 and RS485

DIN rail 2 14 dB 850 nm

DM501-XB1Transceiver

RS232, RS422 and RS485

Type S 2 14 dB 850 nm

DM501-XR1Transceiver

RS232, RS422 and RS485

Rack 2 14 dB 850 nm

DM501-XD2Transceiver

RS232, RS422 and RS485

DIN rail 2 14 dB 1300 nm

DM501-XB2Transceiver

RS232, RS422 and RS485

Type S 2 14 dB 1300 nm

DM501-XR2Transceiver

RS232, RS422 and RS485

Rack 2 14 dB 1300 nm

(2) Maximum attenuation at 62.5/125. For 50/125 reduce optical budget by 3dB.DINrail=45x70x121mm/TypeS=105x95x32mm

Page 32: Optical fibre cables and optoelectronic converters - Policie

Factory and offices: Poligono Industrial Ctra. BV-5128 Km-2208359 Sant Iscle de Vallalta (Barcelona) -Spain-Tel. ++34 93 741 86 86 Fax. ++34 93 741 86 99 e-mail: [email protected] Web: www.optral.com

Madrid delegation: Avenida Valdelaparra 3 Edificio oficinas: 1ª Planta - Oficina 5 28108 Alcobendas ( Madrid ) -Spain-Telf. Comercial: ++34 91 345 08 49Telf. Administración: ++34 93 741 86 86 Fax. ++34 91 359 45 09 e-mail: [email protected] Web: www.optral.com

OPTRAL Chile: Diego de Velásquez 2071 of. 1906Providencia - Santiago - ChileFono: +56-2-7106794Fax: +56-2-7387538Cel: 56-9-0995002e-mail: [email protected]: www.optral.com