Optical Diagnostics T. Tsang BNL (Aug. 4, 2006). Optical Diagnostics tight environment high...

12
Optical Diagnostics T. Tsang BNL (Aug. 4, 2006)
  • date post

    19-Dec-2015
  • Category

    Documents

  • view

    219
  • download

    0

Transcript of Optical Diagnostics T. Tsang BNL (Aug. 4, 2006). Optical Diagnostics tight environment high...

Page 1: Optical Diagnostics T. Tsang BNL (Aug. 4, 2006). Optical Diagnostics tight environment high radiation area non-serviceable area passive components optics.

Optical DiagnosticsT. Tsang

BNL(Aug. 4, 2006)

Page 2: Optical Diagnostics T. Tsang BNL (Aug. 4, 2006). Optical Diagnostics tight environment high radiation area non-serviceable area passive components optics.

Optical Diagnostics

• tight environment

• high radiation area

• non-serviceable area

• passive components

• optics only, no active electronics

• transmit image through flexible fiber bundle

Page 3: Optical Diagnostics T. Tsang BNL (Aug. 4, 2006). Optical Diagnostics tight environment high radiation area non-serviceable area passive components optics.

Optical Diagnostics

test target

retroreflected illumination

Spherical mirror

laser illumination

image collection

Works OK in this tight environment

cm scale

Page 4: Optical Diagnostics T. Tsang BNL (Aug. 4, 2006). Optical Diagnostics tight environment high radiation area non-serviceable area passive components optics.

Optical Diagnosticsoptical design in secondary containment

One set of opticsper viewport

Conceptual design completed

Page 5: Optical Diagnostics T. Tsang BNL (Aug. 4, 2006). Optical Diagnostics tight environment high radiation area non-serviceable area passive components optics.

Sumitomo imaging fibers – used in oue setup

IGN-08/30 sample0.3-meter

30,000 pixels

Cost per foot $78 $158 $305

Cost in 10 meter $2574 $5214 $10065

Total cost for 4 fibers (40 meter) $10.3k $20.8k $40.3k

Rad-hard to 1 Mrad

Page 6: Optical Diagnostics T. Tsang BNL (Aug. 4, 2006). Optical Diagnostics tight environment high radiation area non-serviceable area passive components optics.

Fujikura imaging fibers – Not used

Fujikura data, FIGH-30A continuous 20-meter fiber30,000 pixel imaging fiber

Cost per foot $85 $250 $540

Cost in 10 meter $2805 $8250 $17.8k

Total cost for

4 fibers (40 meter) $11.2k $33k $71.8k

unofficial price info

illumination uniformity

image after a continuous 20-meter long fiber Cost/foot $210 $371.4

Cost in 10 meter $6,935.65 $12,256.7

Cost in 20 meter $15,607.9

Total cost for

4 fibers (40 meter)

$27,742.6 $49,026.8

official price info

Page 7: Optical Diagnostics T. Tsang BNL (Aug. 4, 2006). Optical Diagnostics tight environment high radiation area non-serviceable area passive components optics.

Image quality comparison

camera SMD illuminationNIR pulse, 10 us/frame

30,000 pixels, 1-mm diameter

Fujikura Sumitomo25 cm long 30 cm long

NO significant difference in image qualityShould go with Sumitomo fibers

(20 meters have been ordered)

$210/foot $78/foot delivery in 4 weeksdelivery in 3 months

FIGH-30-850N IGN-08/30

Page 8: Optical Diagnostics T. Tsang BNL (Aug. 4, 2006). Optical Diagnostics tight environment high radiation area non-serviceable area passive components optics.

Grin objective lensimaging fiber – 1 mmillumination fiberfiber holder

All-in-one optical setup

Page 9: Optical Diagnostics T. Tsang BNL (Aug. 4, 2006). Optical Diagnostics tight environment high radiation area non-serviceable area passive components optics.

July 2006Sumitomo IGN08/30 imaging fiber – 20-meter long

NIR 100 µs/frame static image800 x50 x

Page 10: Optical Diagnostics T. Tsang BNL (Aug. 4, 2006). Optical Diagnostics tight environment high radiation area non-serviceable area passive components optics.

New baseplate on mock-up – SMD camera

dynamic image

SMD camera: NIR pulse 100 µs/frame

illumination fiber

imaging fiber

25 Watt pulsed NIR laser

one set of viewport optics

SMD camera

mock-up primary

stationary image

Page 11: Optical Diagnostics T. Tsang BNL (Aug. 4, 2006). Optical Diagnostics tight environment high radiation area non-serviceable area passive components optics.

New baseplate on mock-up – FastVision camera

dynamic image

FastVision camera: NIR pulse 2 ms/frame

stationary image

Page 12: Optical Diagnostics T. Tsang BNL (Aug. 4, 2006). Optical Diagnostics tight environment high radiation area non-serviceable area passive components optics.

• 10-meter imaging fibers will be assembled on mock-up primary• dynamic image collection on both viewports will be tested • 1st camera will be SMD CCD• 2nd camera will be FastVision CCD• 2 sets of viewport/optics/CCD will be ready by the end of August• 3 more 10-meter long imaging fibers in order – viewports 3rd & 4th

Summary