4
R CALL 1-800-999-3600 THI RD ANGLE PROJ ECTI ON DI MENSI ONS I N MI LLI METRES " ALL DI MENSI ONS AND DESI GN CRI TERI A SUBJ ECT TO CHANGE WI THOUT NOTI CE. " PAGE 1OF 4 L732520 FI LE NO. 177- 520 REV. 1 (DI MENSI ONS I N I NCHES ) 0 0 0 0 0 0 0 0 PLAN VIEW 0 0 0 0 0 0 0 0 FRONT VIEW SIDE VIEW 0 0 470 ( 18") 0 0 445 ( 17") 0 0 0 0 0 CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE SEE PLANNING AND SITE PREPARATION GUIDE TP-821233-001 PD 6319. R 0 0 0 0 0 0 0 0 0 A D B C TOP FUNCTION KEY ADVANCED FUNCTION DISPENSER HEIGHT DEPTH HEIGHT DEPTH HEIGHT DEPTH 171 (6") HEIGHT DEPTH HEIGHT - FROM BOTTOM OF SAFE DEPTH - FROM FRONT EDGE OF BEZEL RECEIPT PRINTER 1 1 12 (43") A B C D 1008 (39") 1 126 (44") 5 (") 100 (3") 800 (31 ") AIR INTAKE 0 0 E 0 0 F E F DEPTH DEPTH HEIGHT HEIGHT CARD READER 68 (2") AIR INTAKE AIR INTAKE AIR EXHAUST NOTE: HEADPHONE JACK (ADA) HEADPHONE JACK (CSA) 963 (37") 60 (2") 1 189 (46") 100 (3") 0 0 0 603 ( 23 " ) 733 ( 28 " ) 130 ( 5 " ) 445 (17") 470 (18") 13 (") 13 (") 0 0 470 (18") DO NOT OBSTRUCT OR RESTRICT THE CASH DISPENSER VENTILATION HOLES IN ANY WAY, INCLUDING (BUT NOT LIMITED TO) PLACING THE CASH DISPENSER TOO CLOSE TO OTHER OBJECTS OR INSTALLING ADDITIONAL EQUIPMENT OR SIGNAGE OVER THE VENTILATION HOLES. 0 0 0 0 31 ( 1 " ) 30 ( 1 " ) 40 ( 1 " ) 1373 ( 54 " ) 1272 ( 50 " ) 0 0 0 0 0 0 733 (28") 603 (23") 130 (5") 390 (15") 102 (4") 111 (4") 0 889 ( 35 " ) 610 (24") 0 484 ( 19 " ) OPTEVA 500 LOBBY CASH DISPENSER REAR LOAD 4 HIGH WITH 13mm (") SAFE 1342 ( 52 " ) 1373 ( 54 " ) 0mm TO 76mm (0" TO 3") LEVELING

Transcript of OPTEVA 500 LOBBY CASH DISPENSER REAR LOAD...OPTEVA 500 LOBBY CASH DISPENSER REAR LOAD 4 HIGH WITH...

Page 1: OPTEVA 500 LOBBY CASH DISPENSER REAR LOAD...OPTEVA 500 LOBBY CASH DISPENSER REAR LOAD 4 HIGH WITH 13mm (†") SAFE 1 3 4 2 (2 ” " 1 3 7 3 (5 ") 0mm TO 76mm (0" TO 3") LEVELING T

R

CALL 1-800-999-3600

THIR

D

AN

GL

E

PR

OJ

EC

TIO

N

DIM

EN

SIO

NS IN

MIL

LIM

ET

RES

"AL

L

DIM

EN

SIO

NS

AN

D

DESIG

N

CRIT

ERIA

SU

BJ

EC

T

TO

CH

AN

GE

WIT

HO

UT

NO

TIC

E."

PA

GE 1 O

F 4

L732520

FIL

E

NO. 17

7-520

RE

V. 1

( DIM

EN

SIO

NS IN IN

CH

ES )

00

0 0

0 0

00

PLAN VIEW

0

0 0

0

0

0 00

FRONT VIEW SIDE VIEW

0 0

470 ( 18�")

0 0

445 ( 17�")

0 0

000

CONSULT WITH DIEBOLD INSTALLATION/SERVICE

BRANCH FOR ADDITIONAL DETAILS AND INFORMATION.

PLEASE SEE PLANNING AND SITE PREPARATION GUIDE

TP-821233-001 PD 6319.

R

0

0

0

0 0

0

000

A

D

B

C

TOP

FUNCTION

KEY

ADVANCED

FUNCTION

DISPENSER

HEIGHT DEPTH HEIGHT DEPTH HEIGHT DEPTH

171

(6�")

HEIGHT DEPTH

HEIGHT - FROM BOTTOM OF SAFE

DEPTH - FROM FRONT EDGE OF BEZEL

RECEIPT

PRINTER

1 1 12

(43�")

A B C D

1008

(39�")

1 126

(44�")

5

(�")

100

(3�")

800

(31 �")

AIR INTAKE

00

E

00

F

E F

DEPTHDEPTHHEIGHT HEIGHT

CARD

READER

68

(2�")

AIR INTAKE

AIR INTAKE

AIR EXHAUST

NOTE:

HEADPHONE

JACK (ADA)

HEADPHONE

JACK (CSA)

963

(37�")

60

(2�")

1 189

(46�")

100

(3�")

00

0

603 (2

3�

")

733 (2

8�")

130

(5�

")

445 (17�")

470 (18�")

13 (�") 13 (�")

0 0

470 (18�")

DO NOT OBSTRUCT OR RESTRICT THE CASH DISPENSER VENTILATION HOLES IN

ANY WAY, INCLUDING (BUT NOT LIMITED TO) PLACING THE CASH DISPENSER TOO

CLOSE TO OTHER OBJECTS OR INSTALLING ADDITIONAL EQUIPMENT OR SIGNAGE

OVER THE VENTILATION HOLES.

0

0

00

31 (1�

")

30 (1�

")

40 (1�

")

1373 (5

4�

")

1272 (5

0�

")

00 0 0

00

733 (28�")

603 (23�")130

(5�")

390 (15�")102

(4")

111 (4�")

0

889 (3

5")

610 (24")

0

484 (1

9�

")

OPTEVA 500 LOBBY CASH DISPENSER

REAR LOAD

4 HIGH WITH 13mm (�") SAFE

1342 (5

2�

")

1373 (5

4�

")

0mm TO 76mm (0" TO 3") LEVELING

Page 2: OPTEVA 500 LOBBY CASH DISPENSER REAR LOAD...OPTEVA 500 LOBBY CASH DISPENSER REAR LOAD 4 HIGH WITH 13mm (†") SAFE 1 3 4 2 (2 ” " 1 3 7 3 (5 ") 0mm TO 76mm (0" TO 3") LEVELING T

THIR

D

AN

GL

E

PR

OJ

EC

TIO

N

DIM

EN

SIO

NS IN

MIL

LIM

ET

RES

"AL

L

DIM

EN

SIO

NS

AN

D

DESIG

N

CRIT

ERIA

SU

BJ

EC

T

TO

CH

AN

GE

WIT

HO

UT

NO

TIC

E."

PA

GE 2

OF 4

FIL

E

NO. 17

7-520

RE

V. 1

( DIM

EN

SIO

NS IN IN

CH

ES )

1

1

PROVIDE FLAT COVER WITH TAMPER SWITCH.

1 mm

mm mm

mm mm

mm

mm

mm

E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY SPECIFIC PLUG-IN

NOTE:

ALARM PROTECTION

PHYSICAL SECURITY

WEIGHT OF UNIT

POWER REQUIREMENTS

SAFE LOCATION

OPERATING ENVIRONMENT

HEAT OUTPUT

200-240 VAC (+/-10%) 50Hz (+/-1%) SINGLE PHASE

100-127 VAC (+6%,-10%) 50Hz (+/-1%) SINGLE PHASE

100-127 VAC (+6%,-10%) 60Hz (+/-1%) SINGLE PHASE

200-240 VAC (+/-10%) 60Hz (+/-1%) SINGLE PHASE

RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS. UNLIKE POWER AND

POWER OF ELECTRICAL RUN

TYPE OF ELECTRICAL RUN

UNSHIELDED POWER LINE OR ELECTRICAL EQUIPMENT

LIGHTING CABLE, SIGNAL CABLES HAVE SMALL CONDUCTORS AND LIGHT INSULATION AND WILL NOT

BELOW 2 KVA 2-5 KVA ABOVE 5 KVA

THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS OF THE SIGNAL CABLE RUN

WITH RESPECT TO OTHER POWER AND ELECTRICAL EQUIPMENT CABLE RUN.

127mm (5") 127mm (5") 127mm (5")

305mm (12")

305mm (12")

610mm (2’-0")

64mm (2�") 152mm (6")

152mm (6")76mm (3")30mm (1�")

127mm (5")

FLUORESCENT, NEON OR INCANDESCENT

LIGHTING FIXTURES

POWER LINES IN GROUNDED CONDUIT WITH SIGNAL

CABLES IN GROUNDED CONDUIT

UNSHIELDED POWER LINES OR ELECTRICAL EQUIPMENT

WITH SIGNAL CABLES ENCLOSED IN GROUNDED CONDUIT

MACHINE STATUS

IDLE (NO TRANSACTION)

1

1

1

CONDUIT AND JUNCTION BOX

REQUIREMENTS

E.C. TO RUN 19 (�") LIQUID TIGHT FLEX METAL CONDUIT OR 19 (�") RIGID

CONDUIT FROM JUNCTION BOX TO CABLE CONNECTING PLATE.

BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR

NEW CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED

WITH EXPOSED CONDUIT FOR EXISTING CONSTRUCTION.

THE UL-LISTED SAFE IS EQUIPPED WITH A BASIC ALARM SENSOR PACKAGE. THE

BASIC PACKAGE INCLUDES A SAFE DOOR OPEN SWITCH, ALARM SHUNTING SWITCH,

AND RATE-OF-RISE HEAT SENSOR.

THE SECURITY SAFE MEETS THE BANK PROTECTION ACT 82 STAT 295,

12 USC 882, AND MEETS THE ATTACK TEST PER UL 291-15. THE SAFE DOOR

HAS A POSITIVE RELOCKING FEATURE. THE SAFE DOOR IS CONTROLLED BY A

GROUP 2 COMBINATION LOCK WITH OR WITHOUT KEYLOCKING DIAL CAPABILITY

OR OPTIONAL ELECTRONIC LOCK.

25 ( 1") METAL CONDUIT FROM ALARM CONTROL CABINET JUNCTION BOX TO

102 (4") SQ. X 54 (2�") DP. JUNCTION BOX ( ALL BY E.C. ) DIEBOLD TO

100-127 VAC (+6%, -10%) SERVICE, DISCONNECT AT 20 AMPERES

200-240 VAC (~10%) SERVICE, DISCONNECT AT 10 AMPERES

THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE

POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO

SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN6100-4-11.

210 WATTS

290 WATTS

CONFIGURATION

WITHSTAND AS MUCH STRAIN IN INSTALLATION.

CONFIGURATION

TRANSACTION (DISPENSE

IN PROGRESS)

990 BTU/HR DISPENSING

THE CASH DISPENSER REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER

RECEPTACLE. WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND

(CONDUIT GROUND IS NOT ACCEPTABLE). THE CASH DISPENSER WILL PROVIDE A POWER

CORD WITH A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS

SPECIFIED BELOW.

POWER TO THE CASH DISPENSER MUST BE PROTECTED BY A SAFETY QUICK-

DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT BREAKER AT

THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT

BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE.

POWER USAGE

THE POWER USE DEPENDS ON THE NUMBER AND TYPE OF DEVICES PRESENT IN THE

CASH DISPENSER, AND THE TYPE OF TRANSACTION THE CASH DISPENSER IS PERFORMING.

SIGNAL CABLE RUN CONSTRAINTS

CONNECTOR SUPPLIED WITH UNIT. POWER CORD LENGTH 2210mm (87")

FROM SIDE OF UNIT.

JUNCTION BOXES MUST BE LOCATED WITHIN 2210mm (87") OF CONNECTING

PLATE. ( LENGTH OF ELECTRICAL POWER CABLE PROVIDED WITH UNIT).

LOCATE IN AN EASILY ACCESSIBLE AREA.

SIGNAL CABLE INSTALLATION CONSTRAINTS

(ALL BY E.C.) (SEE POWER REQUIREMENTS).

19 (�") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 102 (4") SQ.

X 54 (2�") DP. JUNCTION BOX WITH RECEPTACLE WITHIN 2210mm (87") OF

SIDE CONNECTING PLATE. BOTTOM CONNECTION MUST BE COMPENSATED ACCORDINGLY

BACK VIEW SIDE VIEW

10 C TO 40 C (50 F TO 104 F)

RELATIVE HUMIDITY ( NON-CONDENSING )

20 TO 80% AT 32 C (90 F),

20 TO 55% AT 38 C ( 100 F)

PROCESSOR, COLOR LCD CONSUMER DISPLAY, MOTORIZED CARD READER,

RECEIPT PRINTER, AND 4 HIGH AFD.

0000

143

(5�")

429 (16�")

38 (1�")

2

2

3

4

3

3

4

AIR EXHAUST

AIR INTAKE

00

0

POWER CORD

000000

350 (13�")

80 (3�")40 (1�")68 (2�")

603 (23�")

0 0

65(2�")

130

(5�")

00

733 (28�")

0

000

80 (3�

")20 (�

")

20

(�")

AIR INTAKE

0 0 0 0 0 0

0 0

445 (17�")

139

(5�")

139

(5�")

51 (2") 57 (2�")59 (2�")

00

000

0 00 0

337 (13�")

54 (2�") 54 (2�")360 (1

4�

")

40 (1�

")40 (1�

")3 (�

")

391 kg ( 862 LBS.)

718 BTU/HR IDLE

NOISE OUTPUT

OPERATING MODE LESS THAN 60 DECIBELS

IDLING MODE LESS THAN 55 DECIBELS

100 (3�")

Page 3: OPTEVA 500 LOBBY CASH DISPENSER REAR LOAD...OPTEVA 500 LOBBY CASH DISPENSER REAR LOAD 4 HIGH WITH 13mm (†") SAFE 1 3 4 2 (2 ” " 1 3 7 3 (5 ") 0mm TO 76mm (0" TO 3") LEVELING T

"AL

L

DIM

EN

SIO

NS

AN

D

DESIG

N

CRIT

ERIA

SU

BJ

EC

T

TO

CH

AN

GE

WIT

HO

UT

NO

TIC

E."

THIR

D

AN

GL

E

PR

OJ

EC

TIO

N

DIM

EN

SIO

NS IN

MIL

LIM

ET

RES

R

CALL 1-800-999-3600

PA

GE 3

OF 4

FIL

E

NO. 17

7-520

RE

V. 1

( DIM

EN

SIO

NS IN IN

CH

ES )

MINIMUM SERVICE AREA

RECOMMENDED SERVICE AREA

ALL ELECTRICAL AND DATA CABLES

MUST ENTER UNIT IN THIS AREA

R

SIDE VIEW

PLAN VIEW ( SINGLE UNIT )

( MINIMUM SERVICE AREA )

0

VA

RIE

S

INSTALLATION/SERVICE AREA

DIMENSION SHOULD ALLOW FOR A

PERSON STANDING DURING INSTALLATION

AND SERVICING OF UNIT.

OPTEVA 500 LOBBY CASH DISPENSER

REAR LOAD

4 HIGH WITH 13mm (�") CHEST

51

(2")

0

00

0

00 00

0 0

89 (3�")89 (3�")

216

(8�")

254

(10")470 (18�")

940 (37")

0

0

0

0

0

0

0

00

0

0

676 (2

6�")

152

(6")

86 (3�")

733 (2

8�")

597 (2

3�

")

813 (32")

2006 (7

9")

NOTE:

SHOWN IS THE MINIMUM/RECOMMENDED AREA REQUIRED FOR INSTALLATION AND

SERVICE. DIMENSIONS SHOWN MAY BE INCREASED WHEREVER POSSIBLE TO

IMPROVE INSTALLATION AND SERVICE ACCESS. USE OF ANY AREA LESS THAN THE

RECOMMENDED AREA MAY RESULT IN AN INCREASE IN INSTALLATION AND SERVICE

TIME. CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR SPECIAL

BUILDING CONDITIONS.

51

(2")

0

00

0 0 0

0

0

0

0

0

0

0

00

0

0

676 (2

6�")

152

(6")

86 (3�")

733 (2

8�")

847 (3

3�

")

404 (15�")366 (14�")

1240 (48�")

2256 (8

8�

")

PLAN VIEW ( SINGLE UNIT )

( RECOMMENDED SERVICE AREA )

00

00

0

102 (4

")

1444 (5

6�

")

0000

0 0 0

00

733 (28�") 676 (26�")597 (23�")

2006 (79")250

( 9�")

2256 (88�")

470 (18�")

1240 (48�")

1342 (5

2�

")

Page 4: OPTEVA 500 LOBBY CASH DISPENSER REAR LOAD...OPTEVA 500 LOBBY CASH DISPENSER REAR LOAD 4 HIGH WITH 13mm (†") SAFE 1 3 4 2 (2 ” " 1 3 7 3 (5 ") 0mm TO 76mm (0" TO 3") LEVELING T

"AL

L

DIM

EN

SIO

NS

AN

D

DESIG

N

CRIT

ERIA

SU

BJ

EC

T

TO

CH

AN

GE

WIT

HO

UT

NO

TIC

E."

THIR

D

AN

GL

E

PR

OJ

EC

TIO

N

DIM

EN

SIO

NS IN

MIL

LIM

ET

RES

PA

GE 4

OF 4

FIL

E

NO. 17

7-520

RE

V. 1

( DIM

EN

SIO

NS IN IN

CH

ES )

0

0

VIEW "B"

0

0102 (4

")MIN.

OWNER’S INSTALLER TO DRILL (4) 19mm (�") DIA. X 203mm (8" MIN.) DEEP HOLES

IN CONCRETE FLOOR (RECOMMENDED DRILLING COMPLETELY THROUGH FLOOR

WHEN POSSIBLE AND TO BE SECURED TO THE CONCRETE FLOOR WITH (4)

19mm (�")-10 X 203mm (8") LONG WEDGE ANCHORS (SUPPLIED BY OWNER’S INSTALLER)

DIEBOLD PART NUMBER 29-016376-000A, HILTI PART NUMBER 282520).

MINIMUM HOLE DEPTH

203mm (8")

MINIMUM CONCRETE DEPTH

102mm (4")

VIEW "A"

203 (8

") M

IN.

(MINIMUM SERVICE AREA)

0 0

89 (3�")

445 (17�")445 (17�")445 (17�")

0

0

0

0

0 0 0 0 0 0 0 0 0

0

0

00750 (29�") 750 (29�")

305

(12")

305

(12")

165

(6�")

476 (18�")

89 (3�")127 (5")

438 (17�")

2414 (95")

0

0

0

0

0

0

676 (2

6�")

733 (2

8�")

597 (2

3�

")

2006 (7

9")

2286 (90")

676 (2

6�")

86 (3�")

152

(6")

0

0

0

0

PLAN VIEW-ADJACENT UNITS

0000

00

0

000

PLAN/SECTION

1

2

(4) 14 (�") DIA. LEVELING LEG HOLES

(4) 22 (�") DIA. FLOOR MOUNTING HOLES36 (1�

")

38 ( 1 �

")

373 (14�")

445 (17�") SAFE

36 (1�")36 (1�")

11

11

22

2 2

143

(5�

")SEE NOTE 2

0

00

00

00

98 (3�

")

454 ( 17�

")

421 ( 16�

")

000

90 (3�

")

609 (2

4") S

AF

E

428 ( 16�

")

120

(4�

")

NOTES:

POWER CABLE PLATE

29 ( 1 �") DIA. HOLE FOR

ALARM CABLES (SIDE ENTRY)

OPENING FOR POWER CORD

AND DATA CABLES

(SIDE ENTRY)

ELECTRICAL AND DATA CABLING ENTERS THE CASH DISPENSER

THROUGH A CABLE ENTRY OPENING ON THE SIDE OF THE SAFE.

CABLES ENTERING THE CASH DISPENSER PASS THROUGHTHE

POWER CABLE PLATE WHICH IS ATTACHED TO THE INSIDE WALL

OF THE SAFE OVER THE CABLE ENTRY OPENING. CABLING CAN

ENTER FROM THE SIDE OR OPTIONALLY FROM UNDER THE CASH

DISPENSER. THE CABLE ENTRY OPENING IS ON THE LEFT SIDE

OF THE SAFE AS VIEWED FROM THE FRONT OF THE CASH

DISPENSER.

FOR ADDED SECURITY:

IT IS RECOMMENDED THAT THE CASH DISPENSER SAFE BE SECURED TO THE FLOOR WITH

ANCHOR BOLTS. USE THE FOLLOWING GUIDELINES TO DETERMINE THE APPROPRIATE METHOD FOR

YOUR INSTALLATION.

ANCHORING THE CASH DISPENSER TO CONCRETE FLOORS:

IT IS RECOMMENDED THAT THE CASH DISPENSER BE ANCHORED TO CONCRETE FLOORS

WHENEVER POSSIBLE. DIEBOLD RECOMMENDS USING A M20 OR 19mm (�") ANCHOR BOLT THAT

IS 203mm (8") LONG. CONCRETE FLOORS OR CONCRETE BASES MUST BE A MINIMUM OF 102mm

(4") THICK FOR ANCHORING TO BE EFFECTIVE. THERE IS NO LIMIT FOR MAXIMUM THICKNESS.

ANCHOR BOLTS MUST BE USED IN ALL AVAILABLE ANCHOR HOLES. IF THE TERMINAL IS

EQUIPPED WITH LEGS, THE LEVELING LEGS MUST BE REMOVED BEFORE THE TERMINAL IS

ANCHORED. REFER TO VIEW "A" AND "B" FOR ADDITIONAL DETAILS.

ANCHORING THE CASH DISPENSER TO WOOD FLOORING:

CASH DISPENSERS INSTALLED ON WOOD FLOORS OR FLOORS SUPPORTED BY WOODED BEAMS

CAN BE SECURED BY A MACHINE-THREADED NUT AND BOLT METHOD. IT IS PREFERRED THAT

THE HARDWARE BE ATTACHED THROUGH SUPPORTING POSTS OR BEAMS FOR MAXIMUM HOLDING

CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH TO A LOCALLY FABRICATED

REINFORCEMENT PLATE INSTALLED UNDERNEATH THE FLOOR TO PROVIDE ADDITIONAL

STRENGTH. THE REINFORCEMENT PLATE IS TYPICALLY 6mm (�") THICK. IT IS IMPORTANT TO

NOTE THAT THE OVERALL HOLDING CAPACITY OF A WOOD FLOOR WILL BE LESS THAN THAT

OF CONCRETE FLOORS.

ANCHORING THE CASH DISPENSER TO STEEL FLOORS:

CASH DISPENSER INSTALLED ON STEEL FLOORS CAN BE SECURED BY A MACHINE-THREADED

METHOD. IT IS PREFERABLE THAT THE HARDWARE BE ATTACHED THROUGH SUPPORTING POSTS

OR BEAMS FOR MAXIMUM HOLDING CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH TO

A LOCALLY FABRICATED REINFORCEMENT PLATE INSTALLED UNDERNEATH THE FLOOR TO

PROVIDE ADDITIONAL STRENGTH. THE COMBINED BACKING PLATE AND FLOOR THICKNESS MUST

BE AT LEAST 13mm (�").