1
SILENT BOXFlow rates up to : 5 m
3/h
Pressure head up to : 53 mCE
Operating pressure : 8 bar
Max. water temperature : +5°à 35°C
Max. ambient temperature : 40°C
Orifice ND : 1”
Max. suction head : 8 m
OPERATING RANGES
N.T. N° 141-12/ENG - Éd. 1/02-05
AUTOMATIC SELF-PRIMINGMULTI-STAGE PUMP
50 Hz
• Distribution of clear, pure water and rainwater• Irrigation • Sprinkling
• Distribution of drinking water • Pressure boosting• Washing
0
53
5Qm3/h
Hm
CE
SILENT BOX
APPLICATIONS
• SILENT BOX
![Page 2: OPERATING RANGES SILENT BOX - amatrade.co.za · silent box sectional drawing 9880 9807 9800 9803 6521 6515 4610a 3712 1400 3690 4610d 9927 9675 9608 9917 9635 9805 8360 9860 8070](https://reader031.fdocuments.in/reader031/viewer/2022020305/5c14d7d009d3f297338c5680/html5/thumbnails/2.jpg)
SILENTBOX 2 04- M
2
SILENT BOX
IDENTIFICATION
DESIGN
• Hydraulics :- Self-priming horizontal pump - Axial suction and upwards vertical dischar-ge with threaded orifices
- Impellers mounted directly on the motor’sextended shaft
- Hydraulic assembly assembled at 8 pointsto a lantern ring
- Shaft/motor leaktightness ensured througha mechanical seal
• Motor- Ventilated 2 pole dry motor- Single-phase: thermal protection with auto-matic repriming
Speed : 2900 rev/minSingle-phase winding : 230 VFrequency : 50hzInsulation class : FProtection index : IP 54CE compliance : NF E
Main parts Material
Impellers Noryl
Stage body Noryl
Mechanical seal Carbon-resin/Nitrile
O-rings NBR
Shaft AISI 420
Knuckle Noryl
Drain pipe Transparent PVC
Pump body AISI 304 stainless steel
Casing Polypropylene
Acoustical foam Polyurethane
Plugs Noryl
BASIC CONSTRUCTION
Pump code
Nominal flow rate in m3/hr
Number of stages
M : single-phase motor
HYDRAULICS PERFORMANCES
0
5
10
15
20
25
30
35
40
45
50
1 2 3 4 5
1 2 3 4 5
1 2 3 4 50,3
0,4
0,5
0,6
0,7
ISO 9906
0
1
2
3
4
204
205
8060
1 1,20,80,60,40,2
4020
N.P.S.H.
m
Qm3/h
Qm3/h
Qm3/h
Hm
P2 kW
Imp.gpm
Ql/min
Ql/s
N.P
.S.H
.
SILENT BOX50Hz
ADVANTAGES
• 43 dB(A) low-level noise running• Plastic shell• All-in-one concept• Built-in check valve• On/off operation• Dry running protection• Adjustable starting pressure• Draining pipe• Simple connections• The pump rests on silent blocks• Built-in filling funnel
![Page 3: OPERATING RANGES SILENT BOX - amatrade.co.za · silent box sectional drawing 9880 9807 9800 9803 6521 6515 4610a 3712 1400 3690 4610d 9927 9675 9608 9917 9635 9805 8360 9860 8070](https://reader031.fdocuments.in/reader031/viewer/2022020305/5c14d7d009d3f297338c5680/html5/thumbnails/3.jpg)
3
SILENT BOX
SECTIONAL DRAWING
PARTS LIST
9220
99443011A3011B9902A4213 4610C11541160B1160A
6545A
225011114610D
9647 11604610B
1170
9941
9923C
2540
8110 9831
9820
9822Rp 1"
Rp1"
6545B
6571
1111 6 STAGE CASING BODY 1160A STAGE BODY with interstage crossover1154 DIFFUSER STAGE1170 CHECK VALVE STAGE1160 VALVE HOLDER STAGE1160B INTERSTAGE CROSSOVER 2250 IMPELLERS3011A BEARING 3011B BEARING
2540 RUBBER DEFLECTOR 4610B SEAL4610C O-RING 4610D O-RING 6545A 1/2 SNAP RING6545B RETAINING RING6571 TIE ROD 8110 HOUSING 9220 IMPELLER SHAFT
9647 METAL VALVE9820 MOTOR FAN 9822 FAN COVER 9831 REAR BEARING FLANGE 4213 STEP HOLDER BOTTOM9923C NUT 9941 WASHER 9944 ELASTIC WASHER 9902A SCREW
![Page 4: OPERATING RANGES SILENT BOX - amatrade.co.za · silent box sectional drawing 9880 9807 9800 9803 6521 6515 4610a 3712 1400 3690 4610d 9927 9675 9608 9917 9635 9805 8360 9860 8070](https://reader031.fdocuments.in/reader031/viewer/2022020305/5c14d7d009d3f297338c5680/html5/thumbnails/4.jpg)
4
SILENT BOX
SECTIONAL DRAWING
9880 9807
9800
9803
6521
6515
4610A 3712 1400
3690
4610D
960896759927
9917
9635
9805
8360
9860
8070 9824
6517
6512
3690 SENSOR MOUNTING 3712 KNUCKLE NUT1400 DISCHARGE KNUCKLE9608 FLOW RATE SENSOR 6515 DRAINING PLUG4610D O-RING 4610A O-RING 6512 FILLING FUNNEL
6521 FILLING PLUG9927 FINE THREAD NUT 9635 DRAINING UNION9675 FLOW RATE SENSOR
RETAINING FORK6517 FLEXIBLE PIPE8360 WIRE HARNESS9860 CAPACITOR
9803 BASE 9800 COVER9917 SCREW 9805 HYDRAULIC TRAP9807 CONTROL PANEL 9880 PUSH BUTTON 8070 PRINTED CIRCUIT BOARD9824 PCB PROTECTOR HOOD
PARTS LIST
![Page 5: OPERATING RANGES SILENT BOX - amatrade.co.za · silent box sectional drawing 9880 9807 9800 9803 6521 6515 4610a 3712 1400 3690 4610d 9927 9675 9608 9917 9635 9805 8360 9860 8070](https://reader031.fdocuments.in/reader031/viewer/2022020305/5c14d7d009d3f297338c5680/html5/thumbnails/5.jpg)
5
SILENT BOX
INSTALLATION DIAGRAMS
CHARACTERISTICS OF THE CONTROL PANEL AND THE AUTOMATIC DEVICE
1
2
3
4
5
Main functions*
1ON/OFF BUTTON Pressing the button for 2 seconds will automatically
prime the pump. The button also allows the manual
repriming of the pump in the event of a fault
2OPERATING INDICATOR The pump is in operation
3VOYANT ATTENTE DE MARCHE The pump is connected to the mains electricity supply
4 FAULT INDICATOR The pump is in "alarm“ mode : dry running protection
5STARTING PRESSURE ADJUSTING The pump is factory preset at 1.5 bar. The pressure can
be adjusted from 0.7 bars to 3.5 bars (see photos)
* For more information about these functions, refer to the installation manual
H A
700
mm
M
IN
100 mm MIN
OU/OR
OPTION
OPTION
500
mm
MIN
1- Check valve
2- Filling plug
3- Draining plug
4- Silent block
5- Power cable
6- On/off button
7- Connecting knuckle
8- Foot valve with strainer
9 - Suction valve
10 - Check/discharge valve
11 - Piping mounting
12 - Strainer
13 - Tank
14 - Suction valve
15 - Tank
![Page 6: OPERATING RANGES SILENT BOX - amatrade.co.za · silent box sectional drawing 9880 9807 9800 9803 6521 6515 4610a 3712 1400 3690 4610d 9927 9675 9608 9917 9635 9805 8360 9860 8070](https://reader031.fdocuments.in/reader031/viewer/2022020305/5c14d7d009d3f297338c5680/html5/thumbnails/6.jpg)
6
SILENT BOX
ELECTRICAL AND DIMENSIONAL PROPERTIES
290
334
181,5
128
507
279
300
G1"
G1"
187,3
ORDER P2 I Capacitor Weight with Weight Electric cable
REFERENCE (kW) 1x 230 µF packaging without packaging (m)
(A) (kg) (kg)
SILENT BOX204- M 0,55 4,2 12,5 12,2 11,2 1,5
SILENT BOX205- M 0,75 5,4 16 14,7 13,7 1,5
H07RNF cable with plug
CHARACTERISTICS
a) Electrical - 230 V-50 hz single-phase (M) with built-inthermal protection and automatic repriming.
- Built-in capacitor.
b) Assembly- Installation in a suction or charge fixedconfiguration.
- No need to secure to the ground. - The silent blocks absorb the system’s vibrations- Connection through flexible pipes with reinforcing helix
- Strainer recommended- Foot valve recommended for pump in asuction configuration
c) Packaging- Delivered ready to use; prewired with plug
d) Maintenance- Assembly/dismantling instructions delivered with the pump
ACCESSOIRES
• Suction kit• Isolating valves• Strainer• Foot valve with strainer• Bladder tanks
ORDER REFERENCE ITEM PART NUMBER
STARKIT G1 (for SILENT BOX 204, 205) 4027874
STARKITSuction kit with 7 m hose, foot valve/strainer,and two fittings (suction and discharge)
53 bd de la République - Espace Lumière - Bât. 6 - 78403 Chatou Cedex- FranceTél. : 33 (0) 820 873 624 - Fax. : 33 (0) 1 30 09 82 82 - www.salmson.fr