REV Electromechanical operatorsfor sliding gatesOperating instructions and warnings

Index

1 Warnings Summary 19 7 Advanced Programming 292 Product Description 20 8 Messages shown on the Display 313 Technical data 20 9 Start-up 314 Installation and Assembly 21 9.1 Installation Test 315 Electrical Connections 9.2 Unlocking and manual operation 31 5.1 Electrical Connections

for 24V models22

10 Maintenance32

5.2 Electrical Connectionsfor 230V models

2411 Product Disposal

32

6 Standard Programming 26

Product ConformityDEA System guarantees the conformity of the product to European Directives 2006/42/CE regarding “machinery safety”,

2004/108/CE“electromagneticcompatibility”and2006/95/CE“lowvoltageelectricalequipment”.SeeDeclaration of Incorpo-ration.

1 WARNINGS SUMMARYReadthesewarningscarefully;failuretorespectthefollowingwarningsmaycauserisksituations.

WARNING Usingthisproductunderunusualconditionsnotforeseenbythemanufacturercancreatesituationsofdanger,andforthisreasonalltheconditionsprescribedintheseinstructionsmustberespected.

WARNINGDEASystemremindsallusersthattheselection,positioningandinstallationofallmaterialsanddeviceswhichmakeupthecompleteautomationsystem,mustcomplywiththeEuropeanDirectives2006/42/CE(MachineryDirective),2004/108/CE(electromagneticcompatibility),2006/95/CE(lowvoltageelectricalequipment).Inordertoensureasuitablelevelofsafety,besidescomplyingwithlocalregulations,itisadvisabletocomplyalsowiththeabovementionedDirectivesinallextraEuropeancountries.

WARNING Undernocircumstancesmusttheproductbeusedinexplosiveatmospheresorsurroundingsthatmayprovecor-rosiveanddamagepartsoftheproduct.

WARNINGToensureanappropriatelevelofelectricalsafetyalwayskeepthe230Vpowersupplycablesapart(minimum4mmintheopenor1mmthroughinsulation)fromlowvoltagecables(motorspowersupply,controls,electriclocks,aerialandauxiliarycircuitspowersupply),andfastenthelatterwithappropriateclampsneartheterminalboards.

WARNING Allinstallation,maintenance,cleaningorrepairoperationsonanypartofthesystemmustbeperformedexclusivelybyqualifiedpersonnelwiththepowersupplydisconnectedworkinginstrictcompliancewiththeelectricalstandardsandregulationsinforceinthenationofinstallation.

WARNING UsingsparepartsnotindicatedbyDEASystemand/orincorrectre-assemblycancreaterisktopeople,animalsandpropertyandalsodamagetheproduct.Forthisreason,alwaysuseonlythepartsindicatedbyDEASystemandscrupulouslyfollowallassemblyinstructions.

WARNINGIncorrectassessmentoftheimpactforcescancauseseriousdamagetopeople,animalsorthings.DEASystemremindstheinstallermustverifythattheimpactforces,measuredasindicatedbythestandardEN12445,areactuallybelowthelimitssetbythestandardEN12453.

WARNINGThecomplianceoftheinternalsensingobstaclesdevicetorequirementsofEN12453isguaranteedonlyifusedinconjunctionwithmotorsfittedwithencoders.

WARNINGAnyexternalsecuritydevicesused forcompliancewith the limitsof impact forcesmustbeconformtostandardEN12978.

WARNINGIncompliancewithEUDirective2002/96/EConwasteelectricalandelectronicequipment(WEEE),thiselectricalproductshouldnotbetreatedasmunicipalmixedwaste.Pleasedisposeoftheproductandbringittothecollectionforanap-propriatelocalmunicipalrecycling.

Page 3: Operating Instructions - Downee

20

2 PRODUCT DESCRIPTIONModels and contents of the package

ThenameREVidentifiesaseriesofelectromechanicaloperatorsforslidinggateswithdifferentfeaturesastomotorandcontrolboardpowersupplyvoltage,capacity,mechanicaladjustmentofforce,electronicclutchandbuilt-inlimitswitch.Allautomatedmo-delsinvolvetheuseofadvancedcontrolunits(NETseries)equippedwithanti-crushingsensor,built-in433MHzradioreceiver,speedcontrolandslowdowninopeningandclosing.TheREVmodelsareintendedprimarilyforresidential/condominiumandSemi-intensive/intensiveusedependingonthedutycycleforeseenfortheautomation.REViscompletedbyasetofaccessorieslistedinthe“PRODUCTACCESSORIES”table(page114).REViscomposedofamechanicalgearmotorwhichrotatesthedrivinggear;Thisgear,coupledtotherackproperlyinstalledonthe

gate,convertsthecircularmotionofthegearmotorintorectilinearmotionthusallowingthemovementofthegateonitsownguide.Inspectthe“ContentsofthePackage”(Pic.1)andcompareitwithyourproductforusefulconsultationduringassembly.

Transport

REVisalwaysdeliveredpackedinboxesthatprovideadequateprotectiontotheproduct,however,payattentiontoallinforma-tionthatmaybeprovidedonthesameboxforstorageandhandling.

3 TECHNICAL DATA

REV220 - REV220/M -REV220/IB

REV220/RF - REV220/RFM - REV220/RF/IB

REV24/F - REV24/M -REV24/IB

Motor power supply voltage (V) 230V~±10%(50/60Hz) 24V

Absorbed power (W) 500 250

Max Thrust (N) 900 1200 450

Work cycle(leaf L=8m)

up to 1000 Kg 27cycles/hour 36cycles/hour

up to 1400 Kg 22cycles/hour 31cycles/hour

Maximum n° of opera-tions in 24 hour(leaf L=8m)

up to 1000 Kg 270 300 300

up to 1400 Kg 220 250 250

Built-in capacitor (µF) 18 -

Operating temperature range (°C) -20÷50°C

Motor thermal protection (°C) 150°C -

Opening speed (m/min) 10 12

Weight of product with package (Kg) 18

Protection degree IPX4

OPERATOR

CONTROL BOARD

NET24N

Power supply (V) 230V~±10%(50/60Hz)

Rated power transformer (VA) 250VA(230/22V)

Fuse F2 (A) (transformer) 2A

Batteries 2x12V1,3A

Fuse F1 (A) (batteries input) 15A

24V operators outputs 1x10A

Warning:Theabovevaluesarecalculatedbytakingthemaximumpowersuppliedbytherespectiveprocessors.Inabsoluteterms,themaximumcurrentfromeachoutputmustnotexceed10A.

Auxiliaries power supply output +24V max200mA

“Warning” output +24V max15W

Electric lock output 24V max5Wormax1art.110

Flashing light output 24V max15W

Operating temperature range (°C) -20÷50°C

Receiver frequency 433,92MHz

Transmitters type of coding HCSfix-code-HCSrollingcode-Dip-switch

Max remote controllers managed 100

NET230N

Power supply (V) 230V~±10%(50/60Hz)

Fuse F2 (A) 5A

Fuse F1 (A) 160mA

230V operators outputs 2x600W

Auxiliaries power supply output 24V~max200mA

“Warning” output 230V~max150W

Electric lock output max1art.110or24V outputmax5Wconfigurable

230V Flashing light output 230V~max40W

24V Flashing light output

24V max100mA(forledflashinglight)art.LED24AIoropengatewarninglight/courtesy

light

Operating temperature range (°C) -20÷50°C

Receiver frequency 433,92MHz

Transmitters type of coding HCSfix-code-HCSrollingcode-Dip-switch

Max remote controllers managed 100

Page 4: Operating Instructions - Downee

21

4 INSTALLATION AND ASSEMBLY4.1 For a satisfactory installation of the product is important to:

• Ensurethatthefacilitycomplieswithcurrentregulationsandthendefinethefullprojectoftheautomaticopening;• Ensurethatthroughoutthecourseofthegate,whileopeningandclosing,therearenofrictionpoints;• Ensurethatthereisnodangerofderailmentandthattherearenotrisksthatitgoesoutoftheguides;• Makesurethegateisinequilibrium:itmustnotmoveifitstaysinanyposition;• Ensurethatthemountingareaofthemotorallowsthereleaseandamanualoperationeasierandsafer;• Ensurethatthemountingpositionsofthevariousdevicesareprotectedfromimpactsandthesurfacesaresufficientlyrobust;• Donotallowtheautomationpartsareimmersedinwaterorotherliquids.

4.2 Defined and satisfied these prerequisites, proceed to the assembly:

If the supporting plane is already available, the fixing of the motor must be done directly on the surface using, for example screw anchors or chemical means.

Alternatively, proceed as follows:

• MakeaholeappropriatetothetypeoflandbyusingasareferencethemeasurementsshowninFig3;• Provideanadequatenumberofchannelsforthepassageofelectricalcables;• Placethebaseofthefoundation;• Startcastingofconcreteand,beforeyoustarttaking,bringingthebaseplatetothedimensionsshowninFigure4,makingsurethatisparalleltothegatewingandperfectlylevel.Waitforthecompletesettingoftheconcrete;

• Removethenutsfromtheplate,thenputthemotoronthebasisoffoundation.

If the rack is already present, place the pinion at a distance of 1-2 mm in order to avoid that the weight of the wing could burden on the gear motor. To do this, adjust the height of the REV with the grains (Fig. 5) and then tighten the nuts in a robust way.

Alternatively, proceed as follows:

• Unlockthemotorandfullyopenthedoor;• Placethefirstsectionoftherackonthewing,makingsurethatthestartoftherackcorrespondstothetopofthewing.Thenattachtheracktotheleafkeepingagameof1-2mmfromthepinion(Fig.6);

• Cutofftheexcesspartoftherack;• Finally,movethedoormanuallyseveraltimesandverifythatthealignmentandthedistanceof1-2mmbetweentherackandpinionisrespectedthroughoutthelength;

• TightenthelocknutsofREVinarobustway(Fig.7)andcoverwithplasticcaps.

4.3 How to unlock the operator

Onceyouopenthelockonthehandle(protectedbyaplasticcover),thelevermustbeturnedinthedirectionshowninFig8,atthispointtheoperatorisunlockedandthegate,intheabsenceofotherobstaclesisfreeinhismovements.Thereverseprocess,turntheleveruntilitstopsandclosingofthelock(remembertoprotectthelockwiththepropercover),keepsREVinworkingcondition.

4.4 Limit-switches

Adjustment of the limit-switches

SomeREVmodelsprovidesalimit-switchwhoseinterventionmustbeadjustedforeachinstallation.DEASystemprovidestwolimitswitchescams(Fig.9)thatareinstalledontherackofthegateandsubsequentlyregulatedinsuchawayastoensurethefunctio-nalityandsafetydistancesinopeningandclosingofthegate.Keepinmindthatwhenthelimitswitchestrigger,thedoorwillmovetoanother2-3cm,andit’sthereforesuggestedtofixtheendofstrokebracketsatasufficientdistancefromthemechanicalstops.

Adjustment of the magnetic limit switchAttachthemountingbracketstothemagnetsasshowninFigure11,making sure to mount the LIGHT BLUE magnet at the closing limit switch, the GREEN magnet at the end of the opening limit switch(Fig.12).Connect the cable of the magnetic sensor which is colored BROWN at the FCC 1 input (Closing Limit Switch 1) and the BLACK one at FCA 1 input (Opening Limit Switch 1)(Fig.13);

WARNINGRefertocontrolboardinstructionstocorrectlyidentifythelimitswitchinputs.WARNINGIncorrectinstallationofthemagnetscanbedangeroustopeopleorthings;observetheconditionsprescribedinthesein-structions.MountthemagneticsensorasshowninFig.10.Thesensormustprotrudefromthebracketforsupportingatleast30mm,inthiswaywillavoidanyinterference.Adjustthemagnetssupportbracketssoastomaintainadistancefromthesensorbetween10and20mm;

4.5 Non self locking models

Nonselflockingmodelsallowthegatetomovemanually,withouthavingtouseareleasekeywhenthepowerfails.Nonselflockingversionsareequippedwithaholdingbrakewhenopening/closing,Thismeansthegatewillbeselflockinginnormalope-ration.Refertotheattachedsheetforthecorrectprocedureofcleaning/maintenanceoftheelectro-brake.DEASystemremindsthat

theoperationsmustbeperformedbyqualifiedpersonnel.

Page 5: Operating Instructions - Downee

22

5.1 ELECTRICAL CONNECTIONS FOR 24V MODELSExecute the wiring following the directions of “Table 1” and diagrams on page 23.

WARNINGToensureanappropriatelevelofelectricalsafetyalwayskeepthe230Vpowersupplycablesapart(minimum4mmintheopenor1mmthroughinsulation)fromlowvoltagecables(motorspowersupply,controls,electriclocks,aerialandauxiliarycircuitspowersupply),andfastenthelatterwithappropriateclampsneartheterminalboards.WARNINGConnecttothepowersupply230V~±10%50Hzthroughamultipoleswitchoradifferentdevicethatcanensuremultipoledisconnectionfromthepowersupply,withacontactopeningof3mm.WARNING Toconnecttheencodertothecontrolpanel,useonlyadedicatedcable3x0,22mm2.

Table 1 “terminal board connections”

1-2 +24V powersupplyoutputforauxiliarydevices200mA

3-4 22V~transformerpowersupplyinput

5-624V batterypowersupplyorphotovoltaicaccumulatorGreenEnergyinput(followcarefullypolarityindications).

7-8 Operator1output

9 Connectionofmotorsmetallicparts

10-11 Operator2output(ifpresent)

12-13 24V max15Woutputforopengatefix/flashingwarninglight(ifP052=0/1)orcourtesylight(ifP052>1)

14-1514 (-) “Boost”outputforelectric-lock,max1xart.110(ifP062=0),24Vpulseoutput,max5W(ifP062=1),

step by step (if P062=2), electro-brake output for not self-locking operators (if P062=3), output forelectric-lockpowersupplyviaexternal relay (ifP062=4),output forelectro-magnetspowersupply forbarriers(ifP062=5)ortemporizedoutput(ifP062>5).15 (+)

16-17 24V Flashinglightoutputmax15Wart.Lumy/24A/S

18-1918 - N.C.

Input6FCC1.IfitintervenesitstopsM1closing.If unused, short circuit.

Iftheinstallationrequiresdifferentcomman-

dsand/oradditionaltothestandard,you

canconfigureeachinputtotherequired

rate.

Refe

r to

Ch

ap

ter

“A

dva

nce

d P

rog

ram

min

g”.

19 - Com

20-2120 - N.C.

Input5FCA1.IfitintervenesitstopsM1opening.If unused, short circuit.21 - Com

22-2322 - N.C. Input4 PHOTO1.Whenenabled (seeparameter P050 in the table), activationof

PHOTO1provokes:aninversionofdirection(duringclosing),thearrestofthemo-vement(duringopening),preventthestart(gateclosed).If unused, short circuit.23 - Com

24-2524 - N.C. Input3SAFETY.Ifactivated,itcausestheinversion.SeeP055andP056onthepara-

meterstable.If unused, short circuit.25 - Com

26-2726 - N.O.

Input2PED.Ifactivated,itopensmotornr.1only.27 - Com

28-2928 - N.O. Input1START.Incaseofinterventionitprovokes:theoperatoropeningorclosing.It

mayoperateas“inversion”mode(P049=0)or“stepbystep”mode(P049=1).29 - Com

30 Aerialsignalinput

31 Groundaerialinput

32-3332 (+)

DE@NETmainsinput(unusedatthemoment)33 (-)

CON 1 230V~±10%(50/60Hz)powersupplyinput

J5 J9 EncoderselectionJumper:•Aposition=operatorswithencoder(remindtosetP029=0)•Bposition=operatorswithoutencoder(remindtosetP029=1)

AB AB

Page 6: Operating Instructions - Downee

23

WIR

ING

DIA

GR

AM

FO

R 2

4V

79

810

1112

1314

1516

17

181920212223242526272829

3130

3332

21 43 65

AB

AB

FLA

SHW

ARN

ING

J5J9

F2

INTE

RNAL

WIR

ING

SET

BY T

HE FA

CTOR

Y

EXTE

RNAL

WIR

ING

SET

BY T

HE IN

STAL

LER

N.O

.

N.O

.

PED

N.C

.

FCA

1N

.C.

RG58

N.C

.

STA

RT

FCC1

TXRX

PHO

TO 1

OPEN GATE WARNING LIGHT24V 15w

FLA

SH

LUM

Y/24

A/S

max

15W

COM

N.O

.

COM

N.O

.

COM

N.C

.

COM

N.C

.

COM

N.C

.

COM

N.C

.

2 x

1 m

m2

2 x

0,5

mm

2

2 x

0,5

mm

2

2 x

0,5

mm

2

2 x

0,5

mm

2

2 x

0,5

mm

2

2 x

0,5

mm

2

2 x

0,5

mm

2

2 x

0,5

mm

2COM

N.C.

N.O.

CON

1

230V

22V

F N

TRA

NSF

ORM

ER23

0V/2

2VPO

WER

SUP

PLY

230V

~ 50

Hz ±

10%

F1

SAFE

TY (O

nly if

need

ed)

RED

BLUE

Brow

n

Blue

Blac

k

Blue

Page 7: Operating Instructions - Downee

24

5.2 ELECTRICAL CONNECTIONS FOR 230V MODELSExecute the wiring following the directions of “Table 2” and diagrams on page 25.

WARNINGToensureanappropriatelevelofelectricalsafetyalwayskeepthe230Vpowersupplycablesapart(minimum4mmintheopenor1mmthroughinsulation)fromlowvoltagecables(motorspowersupply,controls,electriclocks,aerialandauxiliarycircuitspowersupply),andfastenthelatterwithappropriateclampsneartheterminalboards.WARNINGConnecttothepowersupply230V~±10%50Hzthroughamultipoleswitchoradifferentdevicethatcanensuremultipoledisconnectionfromthepowersupply,withacontactopeningof3mm.WARNING Toconnecttheencodertothecontrolpanel,useonlyadedicatedcable3x0,22mm2.

Tabella 2 “collegamento alle morsettiere”

1-2 230V~±10%(50/60Hz)powersupplyinput

3-4-5 Operator1output230V~max600W

6-7-8 Operator2output230V~max600W(ifpresent)

9-10 230V~max150Woutputforopengatewarninglight(ifP052=0)orcourtesylight(ifP052>1)

11-12 Flashinglightoutput230V~max40W

13-1413 (-) “Boost”outputforelectric-lock,max1xart.110(ifP062=0),24Vpulseoutput,max5W(ifP062=1),

step by step (if P062=2), electro-brake output for not self-locking operators (if P062=3), output forelectric-lockpowersupplyviaexternal relay (ifP062=4),output forelectro-magnetspowersupply forbarriers(ifP062=5)ortemporizedoutput(ifP062>5).14 (+)

15-16Output24V max100mA;byselectingtheFL/WLjumper,youcanchoosethe230Flashoutputasa24Voutput(ifthejumperissettoFL)orasaWarninglightoutput(ifjumpersettoWL).Warning:theoutputcapacityallowstouseLEDflashinglightsonly

17-1817 - N.C.

Input6FCC1.IfitintervenesitstopsM1closing.If unused, short circuit.

Iftheinstallationrequiresdifferentcomman-

dsand/oradditionaltothestandard,you

canconfigureeachinputtotherequired

rate.

Refe

r to

Ch

ap

ter

“A

dva

nce

d P

rog

ram

min

g”.

18 - Com

19-2019 - N.C.

Input5FCA1.IfitintervenesitstopsM1opening.If unused, short circuit.20 - Com

21-2221 - N.C. Input4 PHOTO1.Whenenabled (seeparameter P050 in the table), activationof

PHOTO1provokes:aninversionofdirection(duringclosing),thearrestofthemo-vement(duringopening),preventthestart(gateclosed).If unused, short circuit.22 - Com

23-2423 - N.C. Input3SAFETY.Ifactivated,itcausestheinversion.SeeP055andP056onthepara-

meterstable.If unused, short circuit.24 - Com

25-2625 - N.O.

Input2PED.Ifactivated,itopensmotornr.1only.26 - Com

27-2827 - N.O. Input1START.Incaseofinterventionitprovokes:theoperatoropeningorclosing.It

mayoperateas“inversion”mode(P049=0)or“stepbystep”mode(P049=1).28 - Com

29 Aerialsignalinput

30 Groundaerialinput

31-32 24V~powersupplyoutputforauxiliarydevices200mA

33-3433 (+)

DE@NETmainsinput(unusedatthemoment)34 (-)

Page 8: Operating Instructions - Downee

25

WIR

ING

DIA

GR

AM

FO

R 2

30V

21

910

1112

1314

1516

171819202122232425262728

3029

3231

34

56

78

WA

RNIN

GLO

CK

F2F1

FLA

SH23

0VM

OT

1M

OT

2

3433

WL/

FL24

V

FL /

WL

INTE

RNAL

WIR

ING

SET

BY T

HE FA

CTOR

Y

EXTE

RNAL

WIR

ING

SET

BY T

HE IN

STAL

LER

N.O

.

N.O

.

PED

N.C

.

FCA

1N

.C.

RG58

N.C

.

STA

RT

FCC1

TXRX

PHO

TO 1

OPEN GATE WARNING LIGHT230V max 150W

2 x

1 m

m2

2 x

0,5

mm

2

2 x

0,5

mm

2

2 x

0,5

mm

2

2 x

0,5

mm

2

2 x

0,5

mm

2

2 x

0,5

mm

2

2 x

0,5

mm

2

2 x

0,5

mm

2

ENC

M1

FN

BROWN

BLACK

GRAYOMNIPOLAR CIRCUIT BRAKERPOWER SUPPLY230V~ 50Hz ±10%

LN

LUM

Y/A

max

40W FL

ASH

230V

3 x

0,22

mm

2

4 x

1,5

mm

2

3 x 1,5 mm2

COM

N.C.

N.O.

SAFE

TY (O

nly if

need

ed)

Brow

n

Blue

Blac

k

Blue

COM

N.O

.

COM

N.O

.

COM

N.C

.

COM

N.C

.

COM

N.C

.

COM

N.C

.

Page 9: Operating Instructions - Downee

26

6 STANDARD PROGRAMMING

1Power Supply

Givepowersupply,thedisplayshowsthefollowingsymbols“ ”,“ ”,“ ”andthen“----”.

*Ifthecontrolpanelhasalreadybeenprogrammedandthepowerfailsorisswitchedoff-oncepowerisreturnedandaSTARTcommandisgiven,thepositionresetprocedureisperformed(see“rESP”inthetable“WORKINGSTATUSMESSAGES”onpage31.

2Visualisation of inputs and operations-counter status

1. Pressthe keyfor15seconds;

2. Thedisplaywillshowrespectively:

Inputsstatus(checkit’scorrect);

Totaloperationscounter(*seeP064):i.g.: =3x100*=3000operationsperformed

Maintenanceoperations-counter(*seeP065):i.g.: =5*x500=2500operationsremainingbeforethemaintenanceinterventionrequest( =manoeuvres-counterdisabled)

3. Holddownthe keytodisplayacyclic3options,orreleasethe buttontoexittheparameter.

3Selection type of operators ! IMPORTANT !1. Scrolldowntheparameterswith and keysuntilyouvi-sualiseP028;

2. Accesstheparameterbypressingthe key;3. Verifythatthevaluecorrespondstod007(REV),otherwise,youmustselectitbypressing and keys;

4. Confirmyour choicebypressing the key (display returnsagaintoP028).

Page 10: Operating Instructions - Downee

27

4Selection of direction of motion

1. Scrolldowntheparameterswith and keysuntilyouvisualiseP063;

2. Accesstheparameterbypressingthe key;3. Actingon and keys,set: -d000=motorinstandardposition(ontheleftofthegap);

-d001=motorininvertedposition(ontherightofthegap);

4. Confirmyourchoicebypressing the key (di-splayreturnsagaintoP063).

Warning: The parameter automatically reverses the motors output open/close and any limit switch input open/close.

5How to adjust the limit switche

1. Scroll down the parameters untill you visualizeP001;

2. confirmbypressingthe key;3. bypressing (open)and (close),move theleaf in theopeningpositionandadjust the limitswitch cam so that it pushes themicroswitch inthatpoint;

Repeatadjustingtheclosinglimitswitch.4. Confirm by pressing the key (display showsagainP001).

6 Motor stroke learning

1. Makesureyouhaveproperlyadjustedtheopening/closinglimitswitchescams;2. Scrolldowntheparameterswith and keysuntilyouvisualiseP003;3. Accesstheparameterbypressingthe key;4. When“ ”flashes,continuepressingthe key;5. Releasethe keywhen“ ”stopsflashing;Startthelearningprocedurewithoperator1opening;6. Waitforthedoorsearchesandstopsontheopeningstopandthenontheclosingstop.7. Oncetheprocedureisended,thedisplaywillshow“----“.

7Transmitters learning

7.1 Transmitters coding selection

1. Scrolldowntheparameterswith and keysuntilyouvisualiseP027;

2. Confirmbypressingonthe key;3. Selectthetypeoftransmitterbyscrolling and keys: -d000=fixrolling-code(suggested); -d001=completerolling-code; -d002=dip-switch;4. Confirmbypressingonthe key(displayshowsagainP027).

Warning: If you need to vary the type of encoding, and only if other remotes with different encoding are memorized, you need to erase memory (P004) AFTER you have set the new encoding.

Page 11: Operating Instructions - Downee

28

9.2 Learning

1. Scrolldowntheparameterswith and keysuntilyouvisualiseP005;

2. Confirmbypressingonthe key;3. When the symbol “ ” appears, presson any key of the transmitter youwant tomemorize;

4. The display visualizes the number of thetransmitterjustmemorizedandthen“ ”;

5. Memorizeallnecessarytransmittersrepeat-ingthisprocedurefromstep3;

6. Wait10secondsbeforequittingthememo-rizationmode,displayshowsnow“----“.

Warning: In the case of rolling code remotes, the receiver can be put into learning mode by pressing the hidden button on a remote control previously learned.

8Adjustment of operating parameters

Ifyouneedtomodifytheoperatingparameters(force,speednessetc..):

1. Scrolldowntheparametersuntilyouvisualizethedesirepa-rameter(i.g.P032);

2. Confirmbypressingonthe key;3. Bypressingon and ,setupthedesiredvalue;4. Confirmbypressingonthe key(displayshowstheparam-eterspreviouslyselected).

For the complete list of the “Operating Parameters” See the table on page. 34.

9Programming complete

WARNINGAttheendoftheprogrammingprocedure,usethebuttons and untiltheappearanceofthesymbol“----”,theoperatorisnowreadyagainfornewmanoeuvres.

To perform any “Advanced Programming” operations (cancellation of the remotes, configuration inputs, etc. ..), see on page 29.

Page 12: Operating Instructions - Downee

29

7 ADVANCED PROGRAMMINGHerearesomeaddedprogrammingproceduresrelatingtoremotesmemorymanagementandadvancedconfigurationofthe

controlinputs.

1Deletion of memorized transmitters

1.1 Deletion of all transmitters

1. ScrolldowntheparametersuntilyouvisualizeP004;2. Confirmbypressingonthe key;3. When “ ” is flashing, press the key for a fewseconds;

4. Releasethe keyassoonas“ ”stopsflashing;5. Allmemorized transmittershavebeendeleted (displayshowsagainP004).

1.2 How to search and delete a transmitter

1. ScrolldowntheparametersuntilyouvisualizeP006;2. Confirmbypressingonthe key;3. Bypressingon and , keys, select the transmitteryouwanttodelete(eg. );

4. When“ ”flashes,confirmthedeletionbypressingthe keyforafewseconds;

5. Releasethe keywhenappears“ ”;6. Theselectedtransmitterisdeleted(displayshowsagainP006).

2Resetting of default parameters

1. ScrolldowntheparametersuntilyouvisualizeP007;2. Confirmbypressingonthe key;3. When“ ”flashes,pressthe key;4. Releasethe keyassoonas“ ”stopsflashing;Defaultparametersfortheconfigurationcurrentlyinusearerestored;

5. AttheendoftheoperationdisplayreturnstoP007.

Warning: Afteryourestorethedefaultparameters,youmust program the control panel again and adjust alloperatingparameters, inparticular, remember topro-perlysettheconfigurationofparameters(P028-P029-P030–operatorconfiguration).

3Locking-Unlocking access to programming

Byusinga“dip-switch”remote(regardlessofthetypeofremotesalreadymemorized)it’spossibletolock-unlockaccesstothepro-grammingofthecontrolpaneltoavoidtampering.Theremotesettingisthelocking-unlockingcodeverifiedbythecontrolboard.

3.1 Locking access to programming

1. Scrollthroughtheparameterswiththebuttonsand untilthedisplayshowsP008;

2. Accesstheparameterbypressingthebutton ;3. The display shows alternately the writing

toindicatethatthecontrolboardiswaitingforthetransmissionoftheblockcode;

4. Within10secondspressCH1onthe“TXMas-ter”, the display shows beforereturningtothelistofparameters;

5. Accesstoprogrammingislocked.

Page 13: Operating Instructions - Downee

30

3.2 Unlocking access to programming

1. Scrollthroughtheparameterswiththebuttonsand untilthedisplayshowsP008;

2. Accesstheparameterbypressingthebutton ;3. The display shows alternately the writing

toindicatethatthecontrolboardiswaitingforthetransmissionoftheunlockingcode;

4. Within10sec.presstheCH1ofthe“TXMas-ter”, the display shows beforereturningtothelistofparameters;

5. Accesstoprogrammingisunlocked.

3.3 Unlocking access to programming and global reset

WARNING! This procedure involves the loss of all stored settings.

Theprocedureallowstheunlockingofthecontrolpanelwithouthavingtoknowitsunlockingcode.Following this release, you must program the control panelagainandadjustalloperatingparameters,in particular, re-member to properly set the configuration of parame-ters (P028 - P029 - P030 – operator configuration). You will also need to repeat the measurement of impact forces to ensure the installation compliance to standards.

1. Scroll through theparameterswith thebuttons and untilthedisplayshowsP008;

2. Accesstheparameterbypressingthebutton ;3. Thedisplayshowsalternatelythewriting ;4. Press the button , the display shows the flashing writing

;5. Pressthebuttonagainandholdfor5seconds(releasingitbefore,theprocedureisterminated):Thedisplayshowsthefixedwriting followedby ,beforereturningtothelistofparameters;

6. Accesstoprogrammingisunlocked.

4Inputs configuration

Wheretheinstallationrequiresdifferentcommandsand/oradditionaltothestandardonesdescribedbyplan,youcanconfigureeachinputfortheoperationdesired(egSTART,PHOTOS,STOP,etc...).

1. Scrolldowntheparameterswiththe and toseethatcorrespond-ingtothedesiredone:

●P017=forINPUT1; ●P018=forINPUT2; ●P019=forINPUT3; ●P020=forINPUT4; ●P021=forINPUT5; ●P022=forINPUT6;2. Confirmbypressingonthe keytogetaccesstotheparameter(eg.P018);

3. Scrolldownwiththe and ,keystosetthevaluecorrespondingtothedesiredoperation(refertotable“InputConfigurationparameters”on page 33);

4. Confirmbypressingonthe key(displayshowsagainP018).5. Executethenewconnectiontotheinputjustreconfigured.

5Programming complete

WARNINGAttheendoftheprogrammingprocedure,usethebuttons and untiltheappearanceofthesymbol“----”,theoperatorisnowreadyagainfornewmanoeuvres.

Page 14: Operating Instructions - Downee

31

8 MESSAGES SHOWN ON THE DISPLAYWORKING STATUS MESSAGES

Mess. Description

GateisclosedGateisopenedOpeningunderwayClosingunderwayWhileinstep-by-stepmode,thecontrolboardawaitsfurtherinstructionsafterastartcommandStopcommandreceivedResetcurrentposition:Thecontrolunithasjustbeenturnedonafterapowerfailure,orthegatehasexceededthemaximumnumber(80)ofinversionsallowedwithoutevergettingtotheclosingstroke,orthemaximumnumber(3)ofconsecutiveoperationsallowedoftheanti-crushingdevice.Oncethecontrolunithasbeenresetandopencommandgiventhegatewillstartmovingatslowspeed,untilitreachesendoftravel.

ERROR MESSAGESMess. Description Possible solutions

Errorposition:Theresetpositionprocedureisnotsuc-cessful.Thecontrolpanelisawaitingcommands.

-Makesuretherearenospecificfrictionsand/orobstaclesduringtherun;-Giveastartpulsetoinitiateapositionresetprocedure;-Verify that theoperation is completedsuccessfully,manuallyhelping the run, ifnecessary;-Adjustpowerandspeedsettingsifnecessary.

Externalphotocellsand/orsafetydevicesareactivat-edoroutoforder. -Makesurethatallsafetydevicesand/orphotocellsinstalledareworkingproperly.

Possiblefailuretothecontrolboardpowercircuit. -Disconnectandconnectpowersupply.Giveastartimpulse,ifthiserrorappearsagain,replacethecontrolboard.

Time-outoperators run:Theengine/sexceeded themaximum operating time (5min) without ever stop-ping.

-Giveastartpulsetostartthepositionresetprocedure;-Ensurethatthisoperationissuccessful.

Time-outobstacledetection:Withanti-crushingsen-sordisabled,wasstilldetectedthepresenceofanob-staclethatpreventsmovementoftheleafforaperiodof10secondsmore.

-Makesuretherearenospecificfrictionsand/orobstaclesduringtherun;-Giveastartpulsetoinitiateapositionresetprocedure;-Verifythattheoperationiscompletedsuccessfully.

Operatorsmouvementnotdetected.

-Makesurethatoperatorsandencodersconnectionsarewelldone.-CheckthatjumpersJ5andJ9arewellpositionedasshownontheelectricwiring(for24Vonly).-Ifthiserrorappearsagain,replacethecontrolpanel.

9 START-UPThestart-upphaseisveryimportanttoensuremaximumsecurityandcompliancetoregulations,includingalltherequirementsof

EN12445standardwhichestablishesthetestmethodsfortestingtheautomationforgates.DEASystemremindsthatallinstallation,maintenance,cleaningorrepairoperationsonanypartofthesystemmustbeperformed

exclusivelybyqualifiedpersonnelwhomustberesponsibleofalltextsrequiebytheeventualrisk;

9.1 Installation test

Thetestingoperationisessentialinordertoverifythecorrectinstallationofthesystem.DEASystemwantstosummarizethepropertestingofalltheautomationin4easysteps:

• Makesurethatyoucomplystrictlyasdescribedinparagraph2“WARNINGSSUMMARY”;• Testtheopeningandclosingmakingsurethatthemovementoftheleafmatchasexpected.Wesuggestinthisregardtoperformvariousteststoassessthesmoothnessofthegateanddefectsinassemblyoradjustment;

• Ensurethatallsafetydevicesconnectedworkproperly;• Performthemeasurementofimpactforcesinaccordancewiththestandard12445tofindthesettingthatensurescompliancewiththelimitssetbythestandardEN12453.

WARNING UsingsparepartsnotindicatedbyDEASystemand/orincorrectre-assemblycancreatearisktopeople,animalsandpropertyandalsodamagetheproduct.Forthisreason,alwaysuseonlythepartsindicatedbyDEASystemandscrupulouslyfollowallassemblyinstructions.

9.2 Unlocking and Manual operation

Intheeventofmalfunctionsorsimplepowerfailure,releasethemotor(Pic.8)andperformtheoperationmanually.Theknowledgeoftheunlockingoperationisveryimportant,becauseintimesofemergencythelackoftimelinessinactingon

suchadevicecanbedangerous.

WARNINGTheefficancyandsafetyofmanualoperationoftheautomationisguaranteedbyDEASystemonlyiftheinstallationhasbeeninstalledcorrectlyandwithoriginalaccessories.

Page 15: Operating Instructions - Downee

32

10 MAINTENANCEGoodpreventivemaintenanceandregularinspectionensure

longworkinglife.Inthetablebelowyouwillfindalistofinspec-tions/maintenanceoperations tobeprogrammedandexecutedperiodically.Consult the TROUBLE-SHOOTING” tablewheneveranoma-

liesareobservedinordertofindthesolutiontotheproblemandcontactDEASystemdirectlywheneverthesolutionrequiredisnotprovided.

INTERVENTION TYPE PERIODICITY

cleaning of external surfaces 6 months

checking of screw tightening 6 months

checking of release mechanism operation 6 months

electric brake cleaning 6 months

TROUBLE-SHOOTING

Description Possible solutions

When the opening or closing command is activated the gate leaf fails to move and the operator’s electric mo-tor fails to start.

Theoperatorisnotreceivingcorrectpowersupply.Checkallconnections,fuses,andthepowersupplycableconditionsandreplaceorrepairifnecessary.Ifthegatedoesnotclosecheckthecorrectfunctioningofphotocells.

When the opening command is activated, the motor starts but the gate leafs fail to move.

Checkthattheunlockingsystemisclosed(seePic.8).Checktheelectronicforceadjustmentdeviceandthemechanicalclutch.Makesurethatthemotordoesnotpushintheoppositedirection,thelimitswitchelectri-calconnectionsmightbereversed.

The gate moves by fits and starts, it is noisy, it stops at half run or it does not start.

Makesurethatnothinghindersthegatewheelsmovementandtheslideinwhichtheyroll.Therealwaysmustbebacklashbetweenrackandpinion;makesuretherackisaccura-telypositioned.Thepowerofthegearmotormaybeinsufficientforthecharacteristicsofthegate’swing;checkthechoiceofmodelwheneverrequiredh.Iftheoperatorattachmenttothegatebendsorisbadlyfastened,repairand/orbuttressit.

11 PRODUCT DISPOSALREVconsistsofmaterialsofvarioustypes,someofwhichcanberecycled(electricalcables,plastic,aluminum,etc...)whileothers

mustbedisposedof(electronicboardsandcomponents).Proceedasfollows:

1. Disconnectthepowersupply;2. Disconnectanddisassemblealltheaccessoriesconnected.Followtheinstructionsinreversetothatdescribedinthesection“Instal-lation”;

3. Removetheelectroniccomponents;4. Sortinganddisposingofthematerialsexactlyaspertheregulationsinthecountryofsale.

WARNINGInlinewithEUDirective2002/96/ECforwasteelectricalandelectronicequipment(WEEE),thiselectricalproductmustnotbedisposedofasunsortedmunicipalwaste.Pleasedisposeofthisproductbyreturningittoyourlocalmunicipalcol-lectionpointforrecycling.

Page 16: Operating Instructions - Downee

33

PAR

.P

RO

CED

UR

ESE

TTA

BLE

VA

LUES

PROGRAMMING PROCEDURES

Positioningofoperator1

Positioningofoperator2

Memorizationofthemotors’stroke

Deletionoftransmitters

Transmittersmemorizing

Searchanddeletionofatransmitter

Loadingofstandardparameters:thelistisupdatedwithfactorysettings

Lockaccesstoprogramming

HowtolearnconnectedDE@NETdevices(unusedatthemoment)

Unusedparameter

Unusedparameter

Unusedparameter

Unusedparameter

Unusedparameter

Unusedparameter

PAR

.PA

RA

MET

ER D

ESC

RIP

TIO

NSE

TTA

BLE

VA

LUES

DEF

AU

LT V

ALU

ES(fordifferentstandardsofinstallation)

slid

ing

ga

te 2

4V

slid

ing

ga

te 2

30V

INPUTS CONFIGURATION PARAMETERS

INPUT_3selectioninginputtype

•000:IN3type=freecontact

•001:IN3type=constantresistance8K2

(freecontact)

(freecontact)

INPUT_1operatingselection

•000:NONE(unusedparameter)

•001:START(start)

•002:PED.(pedestrian)

•003:OPEN(separatedopen)

•004:CLOSE(separatedclose)

•005:OPEN_PM(manpresentopen)

•006:CLOSE_PM(manpresentclose)

•007:ELOCK-IN(electric-lockactivation.SeeP062)

•008:PHOTO1(photocell1)

•009:PHOTO2(photocell2)

•010:SAFETY1(safetyrib1)

•011:STOP(lock)

•012:FCA1(openinglimitswitchesMot1)

•013:FCA2(openinglimitswitchtesMot2)

•014:FCC1(closinglimitswitchesMot1)

•015:FCC2(closinglimitswitchesMot2)

•016:SAFETY2(safetyrib2)

IN1

(START)

(START)

INPUT_2operatingselection

IN2

(PEDESTRIAN)

(PEDESTRIAN)

INPUT_3operatingselection

IN3

(SAFETY)

(SAFETY)

INPUT_4operatingselection

IN4

(PHOTO1)

(PHOTO1)

INPUT_5operatingselection

IN5

(FCA1)

(FCA1)

INPUT_6operatingselection

IN6

(FCC1)

(FCC1)

AllocationofCHANNEL1ofremotes

•000:NONE(unusedparameter)

•001:START(start)

•002:PEDESTRIAN(pedestrian)

•003:OPEN(separatedopen)

•004:CLOSED(separatedclose)

•005:OPEN_PM(manpresentopen)

•006:CLOSED_PM(manpresentclose)

•007:ELOCK-IN(electric-lockactivation.SeeP062)

CH

1 (START)

(START)

AllocationofCHANNEL2ofremotes

CH

2(NONE)

(NONE)

AllocationofCHANNEL3ofremotes

CH

3(NONE)

(NONE)

AllocationofCHANNEL4ofremotes

CH

4(NONE)

(NONE)

Selectionoftypeofremotes

•000:HCSfix-code

•001:HCSrolling-code

•002:Dip-switch

Page 17: Operating Instructions - Downee

34

slid

ing

ga

te 2

4V

slid

ing

ga

te 2

30V

OPERATORS CONFIGURATION

PARAMETERS

Selectiontypeofoperators

•005:LIVI5/24

•006:LIVI8/24

•007:GULLIVER/REV

Unusedparameter

Unusedparameter

OPERATING PARAMETERS

Operatorsspeedadjustmentduringslow-downwhileopening

Wa

rnin

g

(230V

on

ly):Foroperatorswithout

encoder,speedduringopening/closingcycles(100%)

andslowdownspeedduringopening/closingcycles

(30%)arefixedindependentlyfromsetvalues.

15%tot........................100%tot

Operatorsspeedadjustmentduringthestrokewhileopening

15%tot........................100%tot

Operatorsspeedadjustmentduringthestrokewhileclosing

15%tot........................100%tot

Operatorsspeedadjustmentduringslow-downwhileclosing

15%tot........................100%tot

Slowdowndurationadjustmentwhileopening

5%tot............................80%to

Slowdowndurationadjustmentwhileclosing

5%tot............................80%tot

Operator1forceadjustmentwhileopening

(if=100%obstacledetectiondeactivated)

15%tot…...........................100%tot

Operatorn.1forceadjustmentwhileclosing

(if=100%obstacledetectiondeactivated)

15%tot…...........................100%tot

Unusedparameter

Unusedparameter

Automaticclosingtimesadjustment

(if=0automaticclosingdeactivated)

0sec...................................255sec

Pedestrianautomaticclosingtimeadjustment

(se=0pedestrianautomaticclosingdeactivated)

0sec...................................255sec

Pedestrianstrokedurationadjustment

5%tot…...........................100%tot

Pre-flashingtimeadjustment

0sec…….10sec

Unusedparameter

Unusedparameter

Collectivityfunction:ifitisactivateditdeactivatesbothopeningandclosinginputsforthewholedurationofautomaticopeningandclosing

•000:“collectivityfunction”deactivated

•001:“collectivityfunction”activated

Ramblowfunction:itpushesthemotorsclosedforonesecondbeforeeachopeningmovement,soastoeasetheelectric-lockrelease

•000:“ramblow”deactivated

•001:“ramblowfunction”activated

“Reversal”modeselection(duringthemanoeuvreacommandimpulsereversethemouvement)or“stepbystep”(duringthemanoeuvrea

commandimpulsestopsthemouvement).Anextimpulserestarttheoperatortotheoppositedirection.

•000:“reversalfunction”

•001:“stepbystepfunction”

PHOTO1

PHOTOinputfunctioning:If=0:photocellenabledwhileclosingandstartingwhenthegateisstopped;if=1photocellsare

alwaysenabled;if=2photocellsareenabledwhileclosingonly.Whenenabled,itsactivationprovokes:theinversion(while

closing),thestop(whileopening)andpreventthestarting(whengateisclosed).

If=3-4-5,theoperationisthesameasthevalues0-1-2butwith“closeimmediately”enabled:inanycase,duringtheopening

and/orthepausetime,removalofapossibleobstaclecausesthegateautomaticallyclosesafterafixeddelayof5sec.

•000:photocellenabledwhileclosingandwhengateisstopped

•001:photocellsalwaysenabled

•002:photocellsenabledonlywhileclosing

•003:as000butwith“closeimmediately”enabled

•004:as001butwith“closeimmediately”enabled

•005:as002butwith“closeimmediately”enabled

PHOTO2

Page 18: Operating Instructions - Downee

35

slid

ing

ga

te 2

4V

slid

ing

ga

te 2

30V

OPERATING PARAMETERS

Operationmodeselectionofthewarninglightoutput:

If=0“warninglight”(outputalwaysONwhenthegateisopen,OFFafteraclosingoperation),

If=1“flashingwarninglight”(slowintermittentoutputduringopeningandfastwhileclosing,alwaysONatgateopened,alwaysOFFatthe

endofaclosingoperationonly),

If>1“courtesylight”(outputONduringeachmovement,OFFwhenthemotorstops,afterthesettingdelay)

•000:“fixwarninglight”

•001:“flashingwarninglight”(

on

ly f

or

24V

)•>001:“courtesylight”offdelay

(1sec………………255sec)

Unusedparameter

“softstart”function:motorsaccelerategraduallyuntiltheyreachthesetspeed,avoidingsuddendepartures.

Wa

rnin

g (

230V

on

ly):Foroperatorswithoutencoder,theparameterwillbeingnored.

•000:“softstart”deactivated

•001:“softstart”activated

•002:“longsoftstart”activated

Adjusttheinversiononobstacleperiod(detectedbyinternalanti-crushingsensororbythesafetyinputwhenactivated):If=0itmakesa

completeinversion,if>0indicatestheduration(inseconds)oftherun,afterinversionresultingfromdetectionofanobstacleduringthe

opening.

•000:inversionecompletasuostacolo

•>000:duratadell’inversionesuostacolo

(1sec……………..10sec)

Adjusttheinversiononobstacleperiod(detectedbyinternalanti-crushingsensororbythesafetyinputwhenactivated):If=0itmakesa

completeinversion,if>0indicatestheduration(inseconds)oftherun,afterinversionresultingfromdetectionofanobstacleduringtheclosing.

•000:completereversalonobstacle

•>000:durationofreversalonobstacle

(1sec……………..10sec)

Facilitationmanualrelease:If≠0,afterdetectingthelockingstop,theenginereversesforabrieftimetoreleasethepressureonit,andthus

facilitatethemanualrelease.Thesetvalueshowsthelengthoftheinversion.If=0functiondisabled

•000:facilitatingreleasedisabled

•>000:facilitationactivatedwithreleasetimeequalto:

(1x25ms……….................40x25ms)

Unusedparameter

Unusedparameter

Unusedparameter

“Energysaving”mode:If=1after10secofinactivity,thecontrolpanelturnsthe24Voutputsandthedisplayoffthatwillbeturnedonatfirst

commandreceived(userecommendedbattery-poweredand/orsolarpanel).

•000:“Energysaving”notactive

•001:“Energysaving”active

Electric-lockoutputoperating:If=0“boost”outputforelectric-lockart.110powersupply,If=124VoutputcontrolledbytheELOCK_INinputas

pulsedmode,If=224VoutputcontrolledbytheELOCK_INinputasstep-by-stepmode,If=3electro-brakeoutputfornotself-lockingoperators,

If=424Voutputforelectric-lockpowersupplyviaanexternalrelay,If=524Voutputforelectro-magnetspowersupplyforbarriers,If>524V

outputcontrolledbytheELOCK_INinputastemporizedmode(thesetvalueindicatestheswitch-offdelayinseconds).

•000:“Boost”outputforelectric-lockart.110powersupply

•001:“24V

pulseoutputmax5W

•002:“24V

step-by-stepoutputmax5W

•003:“Electric-lockoutputfornotself-lockingoperators

•004:“Outputforelectric-lockpowersupplyviaanexternalrelay

•005:“outputforelectro-magnetspowersupplyforbarriers

•>005:“24V

temporizedoutputmax5W

(5sec………………255sec)

Rundirectioninversion:If=1automaticallyreversestheoutputsopen/closeoftheoperatorsandanyopening/closinglimitswitchesinputs,

avoidinghavingtomanualchangethewiringwheninstallingtheoperatorinaninvertedposition.

•000:“Standardinstallation”

•001:“Invertedinstallation”

Multiplieroperations-counter:Multiplythenumberofoperationsafterwhichthetotaloperations-counterwillbeupdated.

Toviewthevalues,refertothesection“Visualisationofinputsandoperations-counterstatus”.

•000:“x100

•001:“x1000

•002:“x10000

•003:“x100000

MaintenanceOperations-counter:if=0resetthecounteranddisablestheinterventionrequest,if>0indicatesthenumberofoperations(x

500)tobemadebeforethecontrolpanelexecutesa4secondadditionalpre-flashtoindicatetheneedofmaintenance.

i.g.:IfP064=050,operationsnumber=50x500=25000operations

Wa

rnin

g:Beforeyousetanewvalueofthecounter-manoeuvresmaintenance,thesamemustberesetbysettingP065=0andonlylater

P065=“newvalue”.

•000:“RequestMaintenancedisabled

•>000:“Numberofoperations(x500)forrequiredmaintenance

(1...................................255)

Selectionofoperatingflashinglightoutput:If=0intermittentflashinglightoutput;

If=1Fixedflashinglightoutput(forflashinglightswithintermittentinteriorcircuits).

•000:“intermittentflashinglightoutput

•001:“fixedflashinglightoutput

Page 19: Operating Instructions - Downee

36

slid

ing

ga

te 2

4V

slid

ing

ga

te 2

30V

OPERATING PARAMETERS

SAFETY1

OperationoftheSFTinput:if=0safetyedgealwaysenabled,if=1safetyedgeenabledonlywhileclosing,if=2safetyedge

enabledonlywhileclosingandbeforeanymovement,if=3safetyedgeenabledonlywhenopening,if=4safetyedgeenabled

onlywhileopeningandbeforeanymovement;asfortheobstacledetectionwithinternalanti-crushingsensor,alsotheactivation

oftheinputsSFT1andSFT2causesthecompleteorpartialreversalassetbyP055(durationofinversiononobstacleswhile

opening,andP056(durationofreversalonobstaclewhileclosing)

•000:“safetyedgealwaysenabled

•001:“safetyedgeenabledonlywhileclosing

•002:“safetyedgeenabledonlywhileclosingandbeforeanymovement

•003:“safetyedgeenabledonlywhenopening

•004:“safetyedgeenabledonlywhileopeningandbeforeanymovement

SAFETY2

Delayonlimitswitchdetection:theoperationisstoppedafter1,5secfromlimitswitchdetection.Whenduringthisdelayastopisdetected,

theoperatorissuddenlystopped

•000:“limitswitchdelaydisabled

•001:“limitswitchdelayenabled

Adjustmentofaccelerationdurability

Wa

rnin

g:ifsoftstartisactivated,theaccelerationisdeactivatedindipendentlyfromP070value.

•000:“accelerationdeactivated(itrunsanaccelerationofminimumdurability,

almostimperceptible)

•00X:“adjuststheaccelerationdurabilityat1,5sec(X*6ms)

Unusedparameter

Unusedparameter

Unusedparameter

Unusedparameter

Unusedparameter

Page 20: Operating Instructions - Downee
Page 21: Operating Instructions - Downee

110

223

113

321

388

Page 22: Operating Instructions - Downee

35 ÷

45

500 - 600

400

- 50

030

0 -

400

Page 23: Operating Instructions - Downee
Page 24: Operating Instructions - Downee

113

min 30

Finecorsa magnetico di chiusura (azzurro)Closing magnetic limit switch (light blue)Fin de course magnétique de fermeture (bleu)Final de carrera magnético de cierre (azul)Fim-de-curso de fecho magnético (azul)Wyłączniki krańcowe magnetyczne na zamykaniu (niebieski)

Finecorsa magnetico di apertura (verde)Opening magnetic limit switch (green)Fin de course magnétique d’ouverture (vert)Final de carrera magnético de apertura (verde)Fim-de-curso de abertura magnético (verde)Wyłączniki krańcowe magnetyczne na otwieraniu (zielony)

FCC 1 FCA 1

A

B

C

A Nero, Black, Noire, Negro, Preto, Czarny FCA 1

B Blu, Blue, Bleu, Azul, Azul, Niebieski COM

CMarrone, Brown, Marron, Marrón,

Marrom, BrązFCC 1

Cen

trale

di C

om

an

do

Con

trol B

oa

rd

Page 25: Operating Instructions - Downee

114

Tabella “ACCESSORI PRODOTTO”, Table “PRODUCT ACCESSORIES”, Tableau “ACCESSOIRES PRODUITS”,Tabla “ACCESORIOS PRODUCTO”, Tabela “ACESSÓRIOS DO PRODUTO”, Tabell “AKCESORIA DODATKOWE”.

ArticleCode

Descrizione, Description, Description,Descripción, Descrição, Opis

111619000

Cremagliera in NYLONNYLON rackCrémaillère NYLONCremallera NYLONCremalheira NYLONListwa zębata NYLONOWA

112126001

Cremagliera ZINCATA 22x22ZINC PLATED rack 22x22Crémaillère ZINGUÉE 22x22Cremallera GALVANIZADA 22x22Cremalheira ZINCADA 22x22Listwa zębata METALOWA do spawania 22x22

113126000

Cremagliera ZINCATA 30x12ZINC PLATED rack 30x12Crémaillère ZINGUÉE 30x12Cremallera GALVANIZADA 30x12Cremalheira ZINCADA 30x12Listwa zębata METALOWA do przykręcenia 30x12

Pignone Z22619090

Pignone Z22 per incremento velocità su motori REVZ22 pinion to increase speedness of REV motorsPignon Z22 pour augmenter la vitesse des moteurs REVPiñón Z22 para el incremento de la velocidad del motor REVPinhão Z22 para aumentar a velocidade dos motores REVKoło zębate Z22 zastosowane w celu zwiększenia prędkości na silni-kach REV

Page 26: Operating Instructions - Downee