One Handed Bottle Opener-Optimizado-SimulationXpress Study-1
description
Transcript of One Handed Bottle Opener-Optimizado-SimulationXpress Study-1
-
ITCJ
Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-Optimizado 1
Simulation of One Handed Bottle Opener-Optimizado Date: sbado, 11 de octubre de 2014 Designer: D. Rocha Study name: SimulationXpress Study Analysis type: Static
-
ITCJ
D. Rocha 11/10/2014
Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-
Optimizado 2
Description No Data
Table of Contents Description ........................................... 2
Assumptions .......................................... 3
Model Information .................................. 4
Material Properties ................................. 5
Loads and Fixtures .................................. 6
Mesh Information .................................... 7
Study Results ......................................... 9
Conclusion ........................................... 12
-
ITCJ
D. Rocha 11/10/2014
Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-
Optimizado 3
Assumptions
-
ITCJ
D. Rocha 11/10/2014
Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-
Optimizado 4
Model Information
Model name: One Handed Bottle Opener-Optimizado
Current Configuration: Default
Solid Bodies
Document Name and Reference
Treated As Volumetric Properties Document Path/Date
Modified
Boss-Extrude1
Solid Body
Mass:0.0418569 kg Volume:1.55025e-005 m^3
Density:2700 kg/m^3 Weight:0.410197 N
C:\Users\David Rova\Documents\ITCJ\SE
MESTRE IX\TOP DE DIS CON SIM DE
SOFT\PROYECTO-DESTAPADOR\SLIDOS\One Handed Bottle Opener-
Optimizado.SLDPRT Oct 11 22:24:04 2014
-
ITCJ
D. Rocha 11/10/2014
Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-
Optimizado 5
Material Properties
Model Reference Properties Components
Name: 6061 Alloy Model type: Linear Elastic Isotropic
Default failure criterion:
Max von Mises Stress
Yield strength: 5.51485e+007 N/m^2 Tensile strength: 1.24084e+008 N/m^2
SolidBody 1(Boss-Extrude1)(One Handed Bottle Opener-Optimizado)
-
ITCJ
D. Rocha 11/10/2014
Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-
Optimizado 6
Loads and Fixtures
Fixture name Fixture Image Fixture Details
Fixed-3
Entities: 1 face(s) Type: Fixed Geometry
Load name Load Image Load Details
Force-2
Entities: 1 face(s), 1 plane(s) Reference: Plane1
Type: Apply force Values: ---, ---, -10 lbf
-
ITCJ
D. Rocha 11/10/2014
Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-
Optimizado 7
Mesh Information Mesh type Solid Mesh
Mesher Used: Standard mesh
Automatic Transition: Off
Include Mesh Auto Loops: Off
Jacobian points 4 Points
Element Size 2.09191 mm
Tolerance 0.104595 mm
Mesh Quality High
Mesh Information - Details
Total Nodes 19648
Total Elements 12143
Maximum Aspect Ratio 3.6757
% of elements with Aspect Ratio < 3 99.9
% of elements with Aspect Ratio > 10 0
% of distorted elements(Jacobian) 0
Time to complete mesh(hh;mm;ss): 00:00:03
Computer name: DAROVA
-
ITCJ
D. Rocha 11/10/2014
Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-
Optimizado 8
-
ITCJ
D. Rocha 11/10/2014
Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-
Optimizado 9
Study Results
Name Type Min Max
Stress VON: von Mises Stress 68599.5 N/m^2 Node: 7985
8.02537e+007 N/m^2 Node: 18565
One Handed Bottle Opener-Optimizado-SimulationXpress Study-Stress-Stress
Name Type Min Max
Displacement URES: Resultant Displacement 0 mm Node: 155
0.589447 mm Node: 17830
-
ITCJ
D. Rocha 11/10/2014
Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-
Optimizado 10
One Handed Bottle Opener-Optimizado-SimulationXpress Study-Displacement-Displacement
Name Type
Deformation Deformed Shape
-
ITCJ
D. Rocha 11/10/2014
Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-
Optimizado 11
One Handed Bottle Opener-Optimizado-SimulationXpress Study-Displacement-Deformation
Name Type Min Max
Factor of Safety Max von Mises Stress 0.687177 Node: 18565
803.92 Node: 7985
-
ITCJ
D. Rocha 11/10/2014
Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-
Optimizado 12
One Handed Bottle Opener-Optimizado-SimulationXpress Study-Factor of Safety-Factor of Safety
Conclusion