One Handed Bottle Opener-Optimizado-SimulationXpress Study-1

12
ITCJ Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-Optimizado 1 Simulation of One Handed Bottle Opener- Optimizado Date: sábado, 11 de octubre de 2014 Designer: D. Rocha Study name: SimulationXpress Study Analysis type: Static

description

optimizado

Transcript of One Handed Bottle Opener-Optimizado-SimulationXpress Study-1

  • ITCJ

    Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-Optimizado 1

    Simulation of One Handed Bottle Opener-Optimizado Date: sbado, 11 de octubre de 2014 Designer: D. Rocha Study name: SimulationXpress Study Analysis type: Static

  • ITCJ

    D. Rocha 11/10/2014

    Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-

    Optimizado 2

    Description No Data

    Table of Contents Description ........................................... 2

    Assumptions .......................................... 3

    Model Information .................................. 4

    Material Properties ................................. 5

    Loads and Fixtures .................................. 6

    Mesh Information .................................... 7

    Study Results ......................................... 9

    Conclusion ........................................... 12

  • ITCJ

    D. Rocha 11/10/2014

    Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-

    Optimizado 3

    Assumptions

  • ITCJ

    D. Rocha 11/10/2014

    Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-

    Optimizado 4

    Model Information

    Model name: One Handed Bottle Opener-Optimizado

    Current Configuration: Default

    Solid Bodies

    Document Name and Reference

    Treated As Volumetric Properties Document Path/Date

    Modified

    Boss-Extrude1

    Solid Body

    Mass:0.0418569 kg Volume:1.55025e-005 m^3

    Density:2700 kg/m^3 Weight:0.410197 N

    C:\Users\David Rova\Documents\ITCJ\SE

    MESTRE IX\TOP DE DIS CON SIM DE

    SOFT\PROYECTO-DESTAPADOR\SLIDOS\One Handed Bottle Opener-

    Optimizado.SLDPRT Oct 11 22:24:04 2014

  • ITCJ

    D. Rocha 11/10/2014

    Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-

    Optimizado 5

    Material Properties

    Model Reference Properties Components

    Name: 6061 Alloy Model type: Linear Elastic Isotropic

    Default failure criterion:

    Max von Mises Stress

    Yield strength: 5.51485e+007 N/m^2 Tensile strength: 1.24084e+008 N/m^2

    SolidBody 1(Boss-Extrude1)(One Handed Bottle Opener-Optimizado)

  • ITCJ

    D. Rocha 11/10/2014

    Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-

    Optimizado 6

    Loads and Fixtures

    Fixture name Fixture Image Fixture Details

    Fixed-3

    Entities: 1 face(s) Type: Fixed Geometry

    Load name Load Image Load Details

    Force-2

    Entities: 1 face(s), 1 plane(s) Reference: Plane1

    Type: Apply force Values: ---, ---, -10 lbf

  • ITCJ

    D. Rocha 11/10/2014

    Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-

    Optimizado 7

    Mesh Information Mesh type Solid Mesh

    Mesher Used: Standard mesh

    Automatic Transition: Off

    Include Mesh Auto Loops: Off

    Jacobian points 4 Points

    Element Size 2.09191 mm

    Tolerance 0.104595 mm

    Mesh Quality High

    Mesh Information - Details

    Total Nodes 19648

    Total Elements 12143

    Maximum Aspect Ratio 3.6757

    % of elements with Aspect Ratio < 3 99.9

    % of elements with Aspect Ratio > 10 0

    % of distorted elements(Jacobian) 0

    Time to complete mesh(hh;mm;ss): 00:00:03

    Computer name: DAROVA

  • ITCJ

    D. Rocha 11/10/2014

    Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-

    Optimizado 8

  • ITCJ

    D. Rocha 11/10/2014

    Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-

    Optimizado 9

    Study Results

    Name Type Min Max

    Stress VON: von Mises Stress 68599.5 N/m^2 Node: 7985

    8.02537e+007 N/m^2 Node: 18565

    One Handed Bottle Opener-Optimizado-SimulationXpress Study-Stress-Stress

    Name Type Min Max

    Displacement URES: Resultant Displacement 0 mm Node: 155

    0.589447 mm Node: 17830

  • ITCJ

    D. Rocha 11/10/2014

    Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-

    Optimizado 10

    One Handed Bottle Opener-Optimizado-SimulationXpress Study-Displacement-Displacement

    Name Type

    Deformation Deformed Shape

  • ITCJ

    D. Rocha 11/10/2014

    Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-

    Optimizado 11

    One Handed Bottle Opener-Optimizado-SimulationXpress Study-Displacement-Deformation

    Name Type Min Max

    Factor of Safety Max von Mises Stress 0.687177 Node: 18565

    803.92 Node: 7985

  • ITCJ

    D. Rocha 11/10/2014

    Analyzed with SolidWorks Simulation Simulation of One Handed Bottle Opener-

    Optimizado 12

    One Handed Bottle Opener-Optimizado-SimulationXpress Study-Factor of Safety-Factor of Safety

    Conclusion