onCointion Strters Cointion - Spike Electric€¦ · or U.S. style starters or contactors without...
Transcript of onCointion Strters Cointion - Spike Electric€¦ · or U.S. style starters or contactors without...
CONTACT US:1.844.279.8295 - Toll Free832.243.5372 - Local Factory Support832.569.5645 - [email protected] spikeelectric.com 5914 E. Sam Houston Pkwy S. Houston TX 77034
Copyright © 2018 Spike Electric Controls
CONTROLSelectric
SN4
Combination &
N
on-Combination Starters
SN4 Combination &Non-Combination Starters
5914 E. Sam Houston Pkwy S. Houston TX 77034 | Toll Free 1.844.279.8295 | Local Factory Support 832.243.5372 Fax 832.569.5645 | [email protected] | spikeelectric.com Copyright © 2018 Spike Electric Controls
Applications:• Damp, wet, dirty, dusty areas where ultimate corrosion and
ingress protection is required• Harshmotorcontrolenvironments,including:refineries,
chemical and petrochemical plants, corrosive process facilities, food and beverage, marine and mining
• Across-the-line starting, stopping, speed changing and reversing of polyphased AC induction motors
Design Features:• Available with solid-state electronic overload providing
reliable, accurate and value-driven protection, including communication capabilities, while reducing inventory carrying costs with wide FLA adjustment (5:1) and selectable trip class. And Bi Metallic Thermal overloads.
• Adjustable bimetallic ambient compensated overload relays with interchangeable heater packs – available in three basic sizes, covering applications up to 600 HP
• Fixed heater overloads optional• A full line of snap-on accessories – top and side mounted
auxiliary contacts, solid-state and pneumatic timers• Straight through wiring – line lugs at top, load lugs at bottom• Horizontal or vertical mounting on upright panel for application
freedom• Screw type power terminals have captive, backed-out self-
lifting pressure plates with ± screws for reduced wiring time• Accessibleterminalsforeasywiring;optionalfingerproof
shields available to prevent electrical shock• Top located coil terminals convenient and readily accessible.• 45 mm contactor magnet coils have three terminals, permitting
either top or diagonal wiring – easy to replace European or U.S. style starters or contactors without changing wiring layout
• Encapsulated dual voltage/frequency magnet coils – permanently marked with voltage, frequency and part number
• Designed to meet or exceed UL, CSA, IEC, VDE, BS and other international standards and listings
Certifications:Type Nema 1,12,3R,4,4X, 4X non-metalic ABS Type ApprovedOSHPDCertified(OSP-0015-10)CertifiedType2ordinationNEMAstartersareULCertifiedtoachieveIEC947Type2coordination against 100,000A short circuit fault currents
Standard Material:• Enclosure, external hardware – 316 stainless steel &
Painted Steel• External latching hardware – chrome-plated steel• Internal mounting plate – powder-coated steel• Internal hardware – zinc-plated steel
Electrical ratings:• Motor starters- Single, three-phase- 3-pole, non-reversing, full voltage- NEMA sizes 0-8- Up to 600 HP• Circuit breakers- 3-pole, 600 VAC- 3A through 1200A• Disconnect switches- 3-pole, 600VAC- 15A through 1200A- Fusible and non-fusible• 100,000 rms short circuit rating (480V breakers,
fused disconnects)
5914 E. Sam Houston Pkwy S. Houston TX 77034 | Toll Free 1.844.279.8295 | Local Factory Support 832.243.5372 Fax 832.569.5645 | [email protected] | spikeelectric.com Copyright © 2018 Spike Electric Controls
Wiring SyStem
3 - 3 Phase 1 - Single PhaseBreAKer VOLtAge2 - 240V4 - 480V6 - 600V
nemA SZ
12345678
BrAnd Sufix
Cutler-Hammer WTSquare D DGeneral Electric GLG/LS Economical \ 2 yr warranty LSWEG WGSiemens SIABB ABBAdditions to the circuit breaker or Fused/nonfused disconnectAmbient compensated circuit breaker trip setting ACAuxiliary switch on Circuit Breaker 1A and 1B contacts S784Auxiliary switch on Circuit Breaker 2A and 2B contacts S785Shunt trip on Circuit Breaker S87Bell Alarm on Circuit Breaker S88 100kAIC rated Circuit Breaker in lieu of 65kAIC rated Circuit Breaker S19
EXAMPLE PART NUMBERSN4 7 FTPS200 MCP WT-D 3 S780 W-F
SN4 7 FTPS200 MCP WT-D 3 S780 W-F
StAndArd diScOnnect iS thermAL mAg BreAKerAdder fOr Other diScOnnectS:MCP - motor circuit protectorFD - fused disconnectNF - non fused disconnect
mOtOr StArter AcceSSOrieS
SufixLess overload relays (lighting contactor) CL Less overload relays (motor contactor) CMStarter w/ electronic ground fault overload relay GFAdditional control contacts, N.O. or N.C S780Auxiliary contacts on starter 1 N.O. & 1 N.C S781Auxiliary contacts on starter 2 N.O. & 2 N.C S782Auxiliary contacts on starter 3 N.O. & 3 N.C S783Solid state overload relay SSO1BI Metallic overlaod relay BIElectronic thermal overload relay ETOR
Ac cOiL Sufix
WT120/60 or 110/50 A240/60 or 220/50 B480/60 or 440/50 C600/60 or 550/50 D208/60 E277/60 A208-240/60 9 *Size 00/0 only J
240/50 K EXCPPE380 – 415/50 L550/50 N24/60, 24/50 T EXCPSD24/50 U EXCPSG32/50 VA48/60 1 WDC COIL SUFFIX SYMBOL12VDC F24VDC G48VDC M120VDC PLEGEND PLATESSee Page 4
* Place a daSh (-) between each oPtion in the order liSted above & below
u encLOSure mOdificAtiOnS & AcceSSOrieS cAt #
Control Circuit Transformer, 100VA for NEMA/EEMAC sizes 0–2, 600/480/240–120, 50 / 60 Hertz, with provision for fusing both primary leads and one secondary lead (fuses not provided)
FTPS100
Control Circuit Transformer, 200VA for NEMA/EEMAC size 3, 600/480/240–120, 50 / 60 Hertz, with provision for fusing both primary leads and one secondary lead (fuses not provided).
FTPS200
Control Circuit Transformer, 300VA for NEMA/EEMAC size 4, 5 600/480/240–120, 50 / 60 Hertz, with provision for fusing both primary leads and one secondary lead (fuses not provided)
FTPS300
Control Circuit Transformer, 500VA for NEMA/EEMAC 600/480/240–120, 50 / 60 Hertz, with provision for fusing both primary leads and one secondary lead (fuses not provided)
FTPS500
Pilot light, 120VAC, red jewel, w/blank indicating plate J1Pilot light, 120VAC, green jewel, w/blank indicating plate J3Pilot light, 120VAC, blue jewel, w/blank indicating plate J11Pilot light, 120VAC, amber jewel, w/blank indicating plate J6LED pilot lights (in place of standard incandescent lamps) LEDPilot light push to test, 120VAC, Red or Green *R or G J3PTPilot light push to test, 120VAC, Amber Run Wired to coil J4PTStart-Stop pushbuttons PB23On-Off selector switch RR2Hand-Off-Auto selector switch RR3E-Stop Mushroom head RR4Space heater, 120 Volt, 25 Watts R11Space heater, 240 Volt, 25 Watts R22Space heater, 480 Volt, 25 Watts R44Automatic reset overload relay S1Insulated neutral w/2 connectors S146Std. drain, Class 1, B,C & D; Class 11, E, F & G; Class 111 S756 Std. breather & drain, Class 1, B, C & D; Class 11, E, F & G; Class 111 S756V
External epoxy finish S752Internal and external epoxy finish S75312 Point term. block - 30 Amp, 300V S78612 Point term. block - 30 Amp, 300V Unwired S786UInterposing relay, 2 pole 2 NO 4 NC., coil 120VAC IRGeneral purpose control relay, 4 pole N.O., contacts rated 10A!600V, coil 120VAC GCR
General purpose control relay, 8 pole 4 NO 4 NC., coil 120VAC GCR8Solid State- ON Delay Timer (1-30 secs) ST4Solid State- ON Delay Timer (1-300 secs) ST5Time delay Relay 2 min maximum ON Delay TD1Time delay Relay 2 min maximum OFF Delay TD2Time delay low voltage release relay TDRViewing Window VWTranspearant clear door (Non Metallic only) CDPhoto Cell PCGround Fault Protection Relay GF
cOmBinAtiOn & nOn-cOmBinAtiOn StArterS
Description cAt #Combo Starter N4X 316 SS Rotary SN4X6SSCCombo Starter N4X 316 SS Flanged SN4X6SSCFCombo Starter N4X Non-Metallic Rotary SN4XNMCCombo Starter N4X Non-Metallic Flanged SN4XNMCFCombo Starter N4 Carbon Rotary SN4CCombo Starter N4 Carbon Flanged SN4CFCombo Starter General Purpose Nema 1 Rotary SN41SCCombo Starter General Purpose Nema 1 Flanged SN41SCFNon-Combo Starter N4X 316 SS SN4X6SSSNon-Combo Starter N4X Non-Metallic SN4XNMSNon-Combo Starter N4 Carbon SN4SNon-Combo Starter General Purpose Nema 1 SN41SReversing Combo Starter N4X 316 SS Rotary SN4RX6SSCReversing Combo Starter N4X 316 SS Flanged SN4RX6SSCFReversing Combo Starter N4X Non-Metallic Rotary SN4RXNMCReversing Combo Starter N4X Non-Metallic Flanged SN4RXNMCF
Reversing Combo Starter N4 Carbon Rotary SN4RCReversing Combo Starter N4 Carbon Flanged SN4RCFReversing Combo Starter General Purpose Nema 1 Rotary SN4R1SC
Reversing Combo Starter General Purpose Nema 1 Flanged SN4R1SCF
Reversing Non-Combo Starter N4X 316 SS SN4RX6SSSReversing Non-Combo Starter N4X Non-Metallic SN4RXNMSReversing Non-Combo Starter N4 Carbon SN4RSReversing Non-Combo Starter General Purpose Nema 1 SN4R1S
SN4 Combination &Non-Combination Starters
5914 E. Sam Houston Pkwy S. Houston TX 77034 | Toll Free 1.844.279.8295 | Local Factory Support 832.243.5372 Fax 832.569.5645 | [email protected] | spikeelectric.com Copyright © 2018 Spike Electric Controls
SN4SF-26.75X10.38X6.63-SIZE00 THRU SIZE2
B
A
C E
D
5914 E. Sam Houston Pkwy S.Houston TX, 77077
1-844-279-8295 www.spikeelectric.com
This drawing is the property of Spike Electric Controls and is not to be usedfor any purpose other than that for which it is specifically furnished.
Title
Drawing No. Rev.
Rev. Reason for Issue-Revision DescriptionIssue Date Prep. Chkr. Appv.
Sh
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
G
of
Spike Sales Order No. Customer P.O. No.
RESET
R
GSTART
STOP
STOPPED
G
MOTOR RUN
R
HAND AUTOOFF
SN4SF-36X18.75X8.75-SIZE3 AND SIZE4
B
A
C E
D
5914 E. Sam Houston Pkwy S.Houston TX, 77077
1-844-279-8295 www.spikeelectric.com
This drawing is the property of Spike Electric Controls and is not to be usedfor any purpose other than that for which it is specifically furnished.
Title
Drawing No. Rev.
Rev. Reason for Issue-Revision DescriptionIssue Date Prep. Chkr. Appv.
Sh
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
G
of
Spike Sales Order No. Customer P.O. No.
R
GSTART
STOP
STOPPED
G
MOTOR RUN
R
HAND AUTOOFF
RESET
SN4SF-46X26.75X10-SIZE5
B
A
C E
D
5914 E. Sam Houston Pkwy S.Houston TX, 77077
1-844-279-8295 www.spikeelectric.com
This drawing is the property of Spike Electric Controls and is not to be usedfor any purpose other than that for which it is specifically furnished.
Title
Drawing No. Rev.
Rev. Reason for Issue-Revision DescriptionIssue Date Prep. Chkr. Appv.
Sh
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
G
of
Spike Sales Order No. Customer P.O. No.
RESET
R
GSTART
STOP
STOPPED
G
MOTOR RUN
R
HAND AUTOOFF
encLOSure nOminAL dimenSiOnS in incheS
cAt # A B c d eSiZe 0 cOmBO n41226.75x10.375x6.625 26.75 10.375 6.625 8.894 28.25SIZE 1 COMBO N41226.75X10.375X6.625 26.75 10.375 6.625 8.894 28.25SIZE 2 COMBO N41226.75X10.375X6.625 26.75 10.375 6.625 8.894 28.25SIZE 3 COMBO N41236X18.8X8.75 36 18.8 8.75 17.266 37.5SIZE 4 COMBO N41236X18.8X8.75 36 18.8 8.75 17.266 37.5SIZE 5 COMBO N41246X26.8X10 46 26.8 10 25.192 47.5
SN4 Combination &Non-Combination Starters
5914 E. Sam Houston Pkwy S. Houston TX 77034 | Toll Free 1.844.279.8295 | Local Factory Support 832.243.5372 Fax 832.569.5645 | [email protected] | spikeelectric.com Copyright © 2018 Spike Electric Controls
SingLe functiOn Legend PLAteS
mArKing cAt. #Automatic DSL16Blank DSL01Blank with single field DSL02Close DSL21Down DSL23Emerg. Stop DSL17
Fast DSL46Forward DSL18Hand DSL15In DSL24Jog DSL10Lower DSL27
On DSL07Off DSL08Open DSL20Out DSL25Power On DSL14Raise DSL26
Reset DSL12Reverse DSL19Run DSL09Safe DSL85Slow DSL47Start DSL05
Stop DSL06Test DSL13Trip DSL11Up DSL22
tWO functiOn Legend PLAteS
mArKing cAt. #Blank with 2 fields DSL03For –Rev DSL30Hand-Auto DSL29In-Out DSL35Off-On DSL48Open-Close DSL32
Raise Lower DSL36Run-Jog DSL28Safe-Run DSL86Start-Stop DSL37Slow-Fast DSL65Up-Down DSL33
three functiOn Legend PLAteS
mArKing cAt. #
Auto-Off-Hand DSL49
Blank with 3 fields DSL04
Fast-Off-Slow DSL41
For-Off-Rev DSL40
Hand-Off-Auto DSL39
Run-Off-Jog DSL38
Open-Off-Close DSL43
Raise-Off-Lower DSL87
Slow-Off-Fast DSL88
Up-Off-Down DSL44
1-Off-2 DSL42
Background color for all legend plates is black with the following exceptions:
mArKing cAt. #Start GreenStop RedEmerg.Stop Red
Legend Plates: If desired markings on indicating plates may be added to catalog number after the coil voltage designation. Put a – after the coil voltage & any legend plates that are selected. Select from the list of standard markings below.
SN4 Combination &Non-Combination Starters
5914 E. Sam Houston Pkwy S. Houston TX 77034 | Toll Free 1.844.279.8295 | Local Factory Support 832.243.5372 Fax 832.569.5645 | [email protected] | spikeelectric.com Copyright © 2018 Spike Electric Controls
□
□ □ □ □□ □
□
□ □ □□
□ □
□□□
□ □
□
□
□□□□
□□□
RFQ Questionnaire
SN4 Combination &Non-Combination Starters
5914 E. Sam Houston Pkwy S. Houston TX 77034 | Toll Free 1.844.279.8295 | Local Factory Support 832.243.5372 Fax 832.569.5645 | [email protected] | spikeelectric.com Copyright © 2018 Spike Electric Controls
RFQ Questionnaire
□ □ □□□□
□
□ □ □ □
□
□ □
□ □□ □□ □□
□□□
□□
□