OmniLogic Main Circuit Board (HLX-PCB-MAIN)haywarddocs.info/wp-content/uploads/2017/10/OmniLogic...H...
Transcript of OmniLogic Main Circuit Board (HLX-PCB-MAIN)haywarddocs.info/wp-content/uploads/2017/10/OmniLogic...H...
OmniLogic Main Circuit Board (HLX-PCB-MAIN)
Pg.1
b20v3
A Sensor Blocks (SENS 1-4) N High Voltage Relay Port (HVR 1-4)
B Low Voltage Relays (LVR 1-4) O High Voltage Relay 9 & 10 Ports (HVR 9 (Left) & 10 (Right))
C Valve Actuator Ports (VLV 1-4) P (2) 20 Amp Fuse (Surge Protection)
D (2) Smart Component Comm Ports Q (1) 5 Amp Fuse Prevents Board Overdraw)
E (2) RS485 Comm Terminal Blocks R 120 AC into the board (From Breaker)
F (3) High Speed Buses S 120 AC to Power Supply
G (1) High Speed Terminal Block T Rectifier Input/output AC to DC (Cell Circuit)
H 4 Amp Fuse (Protects Valve Actuator Circuit) U 20 Amp Fuse (Protects the Cell Circuit)
I MSP Power and Comm Port (Local Display) V Transformer Output (Cell Circuit)
J Flow Switch Ports (FLOW SWITCH 1-2) W DC Output from Power Supply (Board Function Power)
K Turbo Cell Female Receptacle (CHLR1) X 4 Amp Fuse (Protect the Transformer - Cell Circuit)
L WiFi Antenna LAN Power (HLWLAN) Y Transformer Input (Cell Circuit)
M Relay Bank Port (HVR 5-8) Z I/O Expansion Socket (For I/O Expansion Card)
OmniLogic: Component Description
A
B
C
D
E
F
G
H
I
J
K
L
M N
O
P Q
R S
T
U V
W
X
Y
Z
Pg.2
**Click On Component To Advance**
OmniLogic: (A) Sensor Block & (B) LVR Block
+3.3VDC
GROUND
+3.3VDC
+3.3VDC
+3.3VDC
+3.3VDC
GROUND
GROUND
GROUND
GROUND
Dry Contact
Dry Contact
Dry Contact
Dry Contact
Pg.3
Table of Contents
OmniLogic: (C) Valve Actuator Circuit
PCB
VLV1 RETURN
VLV2 SUCTION
VLV3
VLV4
ON
OFF +24VAC
+24VAC
GROUND
GROUND
ON
OFF
*Default State is OFF**Note: These circuits are susceptible to shorting. It is recommended to test with the actuators plugged in; if this is not an option extreme care should be used to avoid shorting pins when testing these circuits.
+24VAC
+24VAC
GROUND
GROUND
Pg.4
Table of Contents
OmniLogic: (D) Smart Component Comm Ports & (E) RS485 Comm Terminal Blocks
PCB COMM BUS
COMM BUS
+12VDC=
= GROUND
+12VDC=
= GROUND
COMM BUS
1 2 3 4
1 2 3 4
Port Description
1 +12VDC
2 tX (Data)
3 rX (Data)
4 GROUND
USE: • Sense & Dispense• Color Logic Module
USE: • Variable Speed Pumps
Pg.5
Table of Contents
OmniLogic: (F) High Speed Buses & (G) High Speed Terminal Block
PCB HS BUS
+12VDC=
= GROUND
+12VDC=
= GROUND
Port Description
1 +12VDC
2 tX (Data)
3 rX (Data)
4 GROUND
5 COMMON
USE: • Wired Remotes &
Expansion PanelComm.
USE: • Wired Remotes &
Expansion PanelComm.
HS BUS
HS BUS
+12VDC=
= GROUND
1 2 3 4 5
Pg.6
Table of Contents
OmniLogic: Fuses (H) 4amp, (P) 2x 20amp, (Q) 5amp, (U) 20amp, (X) 4amp
H
P Q
U
X
H 4 amp fuse designed to protect the actuator circuit.
P (2) 20 amp fuses designed the protect the board from an electrical event (such as a heavy voltage spike).
Q 5 amp fuse designed to protect the circuit incase the board draws more than 5amps due to equipment failure.
U 20 amp fuse designed to protect the Chlorinator circuit.
X 4amp fuse designed to protect the Transformer (used for chlorination and valve actuator power).
Pg.7
Table of Contents
OmniLogic: (I) MSP Power & (L) WiFi Antenna LAN Power
+24VDC =
= GROUND
+12VDC =
= GROUND
FOR MSP (Display)
FOR WiFi Power
*Note: These circuits are susceptible to shorting. It is recommended to test on the cables; if this is not an option extreme care should be used to avoid shorting pins when testing these circuits.
Pg.8
Table of Contents
OmniLogic: (M) Relay Bank Port, (N) HVR Port 1-4 & (O) HRV 9+10
*Note: These circuits are susceptible to shorting. It is recommended to test directly on the low voltage side of the relay; if this is not an option extreme care should be used to avoid shorting pins when testing these circuits
RELAY BANK HV BANK
HV9 HV10
+25VDC =
= GROUND
Communication
Pg.9
Table of Contents
OmniLogic: (R) 120AC Main Power IN & (S) 120AC to Power Supply OUT
GROUND =
= 120VAC
120VAC =
= GROUND
NEUTRAL =
= 120VAC
From Breaker
To Power Supply (PSU)
*Test on white connector
*Test on red connector
Pg.10
Table of Contents
OmniLogic: (T) Rectifier Output, (V) Transformer Output & (Y) Transformer Input
120VAC
120VAC
NEUTRAL
NEUTRAL Transformer Supply From Board
(Formerly Blue, White, Violet and
Grey)
Transformer Output Total 24VAC
12VDC
Rectifier Input (Orange) & Output
(Red/Black)
12VDC
24VAC
24VAC
Pg.11
Table of Contents
OmniLogic: (W) DC Output from Power Supply & (Z) I/O Expansion Socket
Z
W
Z
W
GROUND =
= +12VDC
GROUND =
= +24VDC
USE: • DC power off
Power Supply (for most board functions).
USE: • Communication to an I/O
Expansion card for 4 additional valves, low voltage relays and sensors.
Pg.12