2
single OmniBus product can also simulate a control panel or other system components. OmniBus 717 modules have 4 receive and 4 transmit (4R/4T) channels that support both ARINC 717 and its predecessor, ARINC 573. High-speed capability is pro- vided for compatibility with future systems. Each channel is indepen- dently configurable for Har vard biphase or bipolar return-to-zero operation. Superframe support in- cludes user-configurable counter location and number of super- frames per frame. Applications for OmniBus prod- ucts include testing, simulation, and operational uses of avionics databuses. The high channel count, multi-channel capability, and on- board PowerPC processor provide the power necessar y for flight simulators and system integration laboratories. An OmniBus product may also be used as a data server or as a stand-alone converter from one protocol to another. Software The easiest way to use OmniBus 717 products in a Windows® envi- ronment is with the included 717 Monitor program. Users can ob- serve and record word, subframe, and superframe data in octal and binar y formats with just a few clicks of the mouse. The intuitive interface makes it easy to modify sync word values and play back re- corded data files. Alternatively, users can develop their own software using the in- cluded BTIDriver™ API. Although each OmniBus product can be eas- ily configured and run with only a few API calls, the comprehensive librar y includes a broad range of functions for specialized needs. An SDK is available for advanced users who are developing software to run on the PowerPC. 11400 Airport Road, Everett, WA 98204-8782 USA Tel: (800) 829-1553 (425) 339-0281 Fax: (425) 339-0915 E-mail: [email protected] Web: www.ballardtech.com OmniBus ® 717 ARINC 717 for OmniBus Family Products Features 4R/4T ARINC 717 channels per module Each channel individually con- figurable for biphase or bipolar Eight programmable speeds, from 64 to 8192 wps User-configurable sync words and superframes Combine with ARINC 429 chan- nels on the same module Monitor concurrently with transmit/receive operation IRIG time-tags/synchronization Event logging and interrupts Description Ballard’s OmniBus® products connect computers or networks to one or more avionics databuses. OmniBus 717 refers to the ARINC 717 capabilities available for all OmniBus platforms. Separate bro- chures provide information on Om- niBus platforms (PCI, cPCI, VME, USB, Ethernet) and protocols (ARINC 429/708, MIL-STD-1553). OmniBus products are built around an intelligent platform that can host one or more protocol modules. This flexible architecture accommodates mixed protocols, high channel counts, and unsur- passed processing power. An on- board PowerPC® processor can be programmed by the user to off-load the host or for stand-alone opera- tion. Each module has its own DSP dedicated to protocol processing. OmniBus 717 may be used for communicating with and monitor- ing Flight Data Recorder systems. OmniBus 717 can simulate both a DFDAU (Digital Flight Data Acqui- sition Unit) and a DFDR (Digital Flight Data Recorder). With the ad- dition of ARINC 429 channels, a

Transcript of OmniBus 717 Brochure - ADIARINC 717 Module Part Numbers The table below lists standard 717 mod-ules....

Page 1: OmniBus 717 Brochure - ADIARINC 717 Module Part Numbers The table below lists standard 717 mod-ules. Additional configurations and proto-cols may be supported on request. Contact Ballard

single OmniBus product can alsosimulate a control panel or othersystem components.

OmniBus 717 modules have 4receive and 4 transmit (4R/4T)channels that support both ARINC717 and its predecessor, ARINC573. High-speed capability is pro-vided for compatibility with futuresystems. Each channel is indepen-dently configurable for Harvardbiphase or bipolar return-to-zerooperation. Superframe support in-cludes user-configurable counterlocation and number of super-frames per frame.

Applications for OmniBus prod-ucts include testing, simulation,and operational uses of avionicsdatabuses. The high channel count,multi-channel capability, and on-board PowerPC processor providethe power necessary for flightsimulators and system integrationlaboratories. An OmniBus productmay also be used as a data server

or as a stand-alone converter fromone protocol to another.

SoftwareThe easiest way to use OmniBus

717 products in a Windows® envi-ronment is with the included 717Monitor program. Users can ob-serve and record word, subframe,and superframe data in octal andbinary formats with just a fewclicks of the mouse. The intuitiveinterface makes it easy to modifysync word values and play back re-corded data files.

Alternatively, users can developtheir own software using the in-cluded BTIDriver™ API. Althougheach OmniBus product can be eas-ily configured and run with only afew API calls, the comprehensivelibrary includes a broad range offunctions for specialized needs.

An SDK is available for advancedusers who are developing softwareto run on the PowerPC.

11400 Airport Road, Everett, WA 98204-8782 USA Tel: (800) 829-1553 (425) 339-0281 Fax: (425) 339-0915E-mail: [email protected] Web: www.ballardtech.com

OmniBus® 717

ARINC 717for OmniBus Family Products

Features4R/4T ARINC 717 channels permoduleEach channel individually con-figurable for biphase or bipolarEight programmable speeds,from 64 to 8192 wpsUser-configurable sync wordsand superframesCombine with ARINC 429 chan-nels on the same moduleMonitor concurrently withtransmit/receive operationIRIG time-tags/synchronizationEvent logging and interrupts

DescriptionBallard’s OmniBus® products

connect computers or networks toone or more avionics databuses.OmniBus 717 refers to the ARINC717 capabilities available for allOmniBus platforms. Separate bro-chures provide information on Om-niBus platforms (PCI, cPCI, VME,USB, Ethernet) and protocols(ARINC 429/708, MIL-STD-1553).

OmniBus products are builtaround an intelligent platform thatcan host one or more protocolmodules. This flexible architectureaccommodates mixed protocols,high channel counts, and unsur-passed processing power. An on-board PowerPC® processor can beprogrammed by the user to off-loadthe host or for stand-alone opera-tion. Each module has its own DSPdedicated to protocol processing.

OmniBus 717 may be used forcommunicating with and monitor-ing Flight Data Recorder systems.OmniBus 717 can simulate both aDFDAU (Digital Flight Data Acqui-sition Unit) and a DFDR (DigitalFlight Data Recorder). With the ad-dition of ARINC 429 channels, a

Page 2: OmniBus 717 Brochure - ADIARINC 717 Module Part Numbers The table below lists standard 717 mod-ules. Additional configurations and proto-cols may be supported on request. Contact Ballard

BR154-20081030

OmniBus 717Ordering Information:OmniBus Order NumbersOmniBus Order NumbersOmniBus Order NumbersOmniBus Order NumbersOmniBus Order Numbers

The order number for an OmniBus productis a combination of the board part number(see table below) and module partnumber(s). For example, order number111-431 is an OmniBus PCI board with a4R/4T ARINC 717 module.

ARINC 717 Module Part NumbersARINC 717 Module Part NumbersARINC 717 Module Part NumbersARINC 717 Module Part NumbersARINC 717 Module Part NumbersThe table below lists standard 717 mod-ules. Additional configurations and proto-cols may be supported on request. ContactBallard for details.

*On module P/N 435, ARINC 429 and bipolar ARINC 717channels share the same receivers.

Example Configurations:717 Configurations for 2 Modules717 Configurations for 2 Modules717 Configurations for 2 Modules717 Configurations for 2 Modules717 Configurations for 2 Modules

Up to 8R/8T ARINC 717 channels 4R/4T ARINC 717 channels

plus 12R/12T ARINC 429 channels 4R/4T ARINC 717 channels

plus 4R/4T ARINC 429 channelsand 1 or 2 MIL-STD-1553 channels

717 Configurations for 4 Modules717 Configurations for 4 Modules717 Configurations for 4 Modules717 Configurations for 4 Modules717 Configurations for 4 Modules Up to 16R/16T ARINC 717 channels 12R/12T ARINC 717 channels

plus 20R/20T ARINC 429 channels 4R/4T ARINC 717 channels

plus 4R/4T ARINC 429 channelsand 4R/4T ARINC 708 channelsand 1 or 2 MIL-STD-1553 channels

11400 Airport RoadEverett, WA 98204-8782 USA

Tel: (800) 829-1553 (425) 339-0281Fax: (425) 339-0915

E-mail: [email protected]: www.ballardtech.com

ARINC 717 Functional SpecificationsGeneralGeneralGeneralGeneralGeneral

Each ARINC 717 module has 4 receive and 4 transmit (4R/4T) channelsEach channel is software-configurable for Harvard biphase or bipolar RZChannel speed may be independently set for 64, 128, 256, 512, 1024, 2048, 4096 or 8192 wpsStandard or user-specified sync words for each channelAccess words by word, subframe, and/or superframe numberSuperframe support:

User-specified superframe counter locationUser-specified number of frames per superframe

Internal wrap-around self-test bus facilitates built-in test and diagnostics

TTTTTransmittersransmittersransmittersransmittersransmittersVary the transmit amplitude under software controlTrigger options (3 trigger inputs per module):

Configure transmitter to wait for trigger signalAssign one trigger to multiple transmit channels for synchronized operationProgrammable polarity eases integration with external equipmentUse one or more trigger lines and conditions to create multiple unique triggers

Output a sync signal on all or selected subframes (3 sync lines per module)

ReceiversReceiversReceiversReceiversReceiversConfigure receivers to auto-detect speed (default) or specify a fixed speedIn-sync and out-of-sync status reportingOptional notification if receiver loses sync (interrupt/log entry)Each received subframe record includes:

12-bit data wordstime-tagchannel numberbus speed

Sequential MonitorSequential MonitorSequential MonitorSequential MonitorSequential MonitorCreate a sequential record in on-board memory or stream to file (with a simple program)Monitor concurrently with transmitter/receiver operationCapture user-selected 717 wordsMonitor recording modes:

circularfill and halt

TTTTTime-Time-Time-Time-Time-TagsagsagsagsagsUse 32-bit binary timer or 64-bit IRIG timer (displays day/hour/min/sec/ms/µs)IRIG timer options:

Select IRIG-B or IRIG-A formatGenerate IRIG signal or sync up to an IRIG signal (on-board or external)Initialize timer to time of day or other value

Interrupts/LoggingInterrupts/LoggingInterrupts/LoggingInterrupts/LoggingInterrupts/LoggingConfigurable event log can be polled and can generate interrupts to the host PCThe following events may be user-selected for logging/interrupts:

When the monitor is full or haltsOn a user-specified frequency of monitored messagesWhen tagged words are sent or receivedWhen tagged subframes are sent or receivedWhen a receive channel loses sync

OmniBus®, OmniBusBox™, and BTIDriver™ are trademarks ofBallard Technology, Inc. PowerPC® is a registered trademarkof IBM (International Business Machines Corporation).

OmniBus Products:OmniBus Products:OmniBus Products:OmniBus Products:OmniBus Products: OmniBus PCI OmniBus cPCI OmniBus VME OmniBusBox (Ethernet/USB)

OmniBus Protocols:OmniBus Protocols:OmniBus Protocols:OmniBus Protocols:OmniBus Protocols: MIL-STD-1553 ARINC 429 ARINC 708 ARINC 717

eroC1 seroC2 seroC4

)trohs(ICP 111 211 —

)U3(ICPc 121 221 —

)U6(EMV — 251 451

BSU/tenrehtE — 261 —

N/P noitpircseD

134 717CNIRAT4/R4

*534 htiw717CNIRAT4/R4*924cirtemarapT4/R4