omega r&d inc. iNstall Guide OL-AL(MIB)-GD · CHeVroleT Aveo ( LS ) 04-08 1 Aveo 5 ( LS ) 04-08 1...

6
NOTICE: The manufacturer will accept no responsibility for any electrical damage resulting from improper installation of this product, be that either damage to the vehicle itself or to the installed device. This device must be installed by a certified technician. This guide has been written for properly trained technicians; a certain level of skill & knowledge is therefore assumed. Please review the Installation Guide carefully before beginning any work. ! Omega R&D Inc. INSTALL GUIDE OL-AL(MIB)-GD AVAILABLE FOR : OL-MIB-ALL GD The brand names and logos found in this guide are property of their respective owners. Omega R&D Inc. © 2010 Rev. Date: June 17, 2010 Doc. No.: ##3461## 20100326 Alarms & Remote Start

Transcript of omega r&d inc. iNstall Guide OL-AL(MIB)-GD · CHeVroleT Aveo ( LS ) 04-08 1 Aveo 5 ( LS ) 04-08 1...

NOTICE: The manufacturer will accept no responsibility for any electrical damage resulting from improper installation of this product, be that either damage to the vehicle itself or to the installed device. This device must be installed by a certified technician. This guide has been written for properly trained technicians; a certain level of skill & knowledge is therefore assumed. Please review the Installation Guide carefully before beginning any work.

!

omega r&d inc.

iNstall Guide OL-AL(MIB)-GD AvAILABLe fOR : OL-MIB-ALL

GD

The brand names and logos found in this guide are property of their respective owners. Omega R&D Inc. © 2010

Rev. Date: June 17, 2010Doc. No.: ##3461##20100326

A l a r m s & R e m o t e S t a r t

inStaLL tyPe SeLeCtiOn

XX-XX PAGE X-XADS-TB-GD PAGE 2-2

ma

Ke

mo

Del

yea

r

INsT

all

Typ

e

CH

eVr

ole

T Aveo ( LS ) 04-08 1

Aveo 5 ( LS ) 04-08 1

Epica ( LS / LT ) 04-07 2p

oN

TIa

C Wave 05-08 1

Wave 5 05-08 1

sUzU

KI

Swift+ 04-08 1

Verona 04-06 2

Page 2 of 6 OL-AL(MIB)-GD 20100326

iNstall Guide

omega research & development inc. © 2010

ImmobIlIzer bypassGM/Daewoo

Doc. No.: ##3461##

tyPe 1 - Wiring diagram

XX-XX PAGE X-X

tyPe 1 - Wire CrOSS reFerenCe CHart

ADS-AL(TB)-GD T1 PAGE X-X

ma

Ke

mo

Del

yea

r

IGNITIoN DaTa CoNNeCTor

po

sITI

oN

WIr

e C

olo

r

po

sITI

oN

WIr

e C

olo

r

Na

me

Typ

e

loCa

TIo

N

CH

eVr

ole

T Aveo ( LS ) 04-07 1 Pink 6 Black/White D 7 pin At key barrel

Aveo ( LS ) 08 1 Pink 6 Brown/White D 7 pin At key barrel

Aveo 5 ( LS ) 04-07 1 Pink 6 Black/White D 7 pin At key barrel

Aveo 5 ( LS ) 08 1 Pink 6 Brown/White D 7 pin At key barrel

po

NTI

aC Wave 05-07 1 Pink 6 Black/White D 7 pin At key barrel

Wave 08 1 Pink 6 Brown/White D 7 pin At key barrel

Wave 5 05-07 1 Pink 6 Black/White D 7 pin At key barrel

Wave 5 08 1 Pink 6 Brown/White D 7 pin At key barrel

sUzU

KI Swift+ 04-07 1 Pink 6 Black/White D 7 pin At key barrel

Swift+ 08 1 Pink 6 Brown/White D 7 pin At key barrel

Page 3 of 6 OL-AL(MIB)-GD 20100326

iNstall Guide

omega research & development inc. © 2010

ImmobIlIzer bypassGM/Daewoo

MOVE THE FOLLOWING ITEMS IN YOURSCHEMATIC WITH ALL LAYERS ON

USE THE FOLLOWING LAYER SPECIFIC ITEMS ASWIRING AND TEXT TEMPLATES

CONNECT EITHER DBI OR

STANDARD WIRING

DBI PORT REQUIREDON REMOTE STARTER. IF UNAVAILABLE

USE STANDARD WIRING METHOD

LEGEND

Wiring connections not requiredwhen using the DBI Port.

DBI PORT

BLUE/RED (NC) BLUE/YELLOW (NC)GREEN/RED (NC)GREEN/YELLOW (NC)GRAY/RED (NC)GRAY/YELLOW (NC)

ORANGE (NC)ORANGE/WHITE (NC) ORANGE/BLACK - DATABROWN/YELLOW (NC)BROWN/RED (NC)

YELLOW (NC)YELLOW/RED (NC)YELLOW/BLACK (NC)

PINK/BLACK - IGNITION OUTPUTPINK - IGNITION INPUT

GWR (-) - BLUE/WHITE(NC) WHITE

GROUND - BLACK12V - RED

REMOTESTARTER

OR

SECURITYSYSTEM

OR

KEYLESSENTRY

WHITE (NC) WHITE/RED - ALARM OUT FUSE WHITE/BLACK - ALARM IN ECM

(NC) GREEN/BLACK(NC) BLUE/BLACK

(NC) RED/WHITE (NC) BROWN

(NC) PURPLE/YELLOW (NC) PURPLE/BLACK

(NC) INPUT - WHITE(NC) BLACK/WHITE

(NC) GREEN(NC) PURPLE/WHITE

OPTIONAL USE TO ISOLATE OEM ALARM IGNITION PINK WIRE BEHIND CENTER CONSOLE

PIN

K - IG

NITIO

N FR

OM

ECM

BLA

CK/W

HITE O

R B

RO

WN

/WH

ITE - DA

TA

If the ignition wire (located behind center console) is interupted by the iDatalink module, there is no need to override the vehicle factory alarm. This installation method will ensure your factory keyfob will at all times function normally (including during remote start).

Front view of connector

D

Doc. No.: ##3461##

tyPe 2 - Wiring diagram

XX-XX PAGE X-X

Wire CrOSS reFerenCe CHart

XX-XX PAGE X-X

tyPe 2 - Wire CrOSS reFerenCe CHart

ADS-AL(TB)-GD T2 PAGE X-X

ma

Ke

mo

Del

yea

r

DaTa CoNNeCTor seCUrITy lIGHT CoNNeCTor

po

sITI

oN

WIr

e C

olo

r

Na

me

Typ

e

loCa

TIo

N

po

sITI

oN

WIr

e C

olo

r

Na

me

Typ

e

loCa

TIo

N

CH

eVr

ole

T

Epica ( LS / LT ) 04-07 7 Green/Black E 15 pin At BCM 20 Yellow/Black F 30 pin At BCM

sUzU

KI

Verona 04-06 7 Green/Black E 15 pin At BCM 20 Yellow/Black F 30 pin At BCM

Page 4 of 6 OL-AL(MIB)-GD 20100326

iNstall Guide

omega research & development inc. © 2010

ImmobIlIzer bypassGM/Daewoo

MOVE THE FOLLOWING ITEMS IN YOURSCHEMATIC WITH ALL LAYERS ON

USE THE FOLLOWING LAYER SPECIFIC ITEMS ASWIRING AND TEXT TEMPLATES

CONNECT EITHER DBI OR

STANDARD WIRING

DBI PORT REQUIREDON REMOTE STARTER. IF UNAVAILABLE

USE STANDARD WIRING METHOD

LEGEND

Wiring connections not requiredwhen using the DBI Port.

DBI PORT

BLUE/RED - SECURITY LIGHT INBLUE/YELLOW - SECURITY LIGHT OUTGREEN/RED (NC)GREEN/YELLOW (NC)GRAY/RED (NC)GRAY/YELLOW (NC)

ORANGE (NC)ORANGE/WHITE (NC) ORANGE/BLACK - DATABROWN/YELLOW (NC)BROWN/RED (NC)

YELLOW (NC)YELLOW/RED (NC)YELLOW/BLACK (NC)

PINK/BLACK (NC)PINK - IGNITION (+) INPUT

GWR (-) - BLUE/WHITE(NC) WHITE

GROUND - BLACK12V - RED

REMOTESTARTER

OR

SECURITYSYSTEM

OR

KEYLESSENTRY

WHITE (NC) WHITE/RED - DATA ECM SIDEWHITE/BLACK - DATA BCM SIDE

(NC) GREEN/BLACK(NC) BLUE/BLACK

(NC) RED/WHITE (NC) BROWN

(NC) PURPLE/YELLOW (NC) PURPLE/BLACK

(NC) INPUT - WHITE(NC) BLACK/WHITE

(NC) GREEN(NC) PURPLE/WHITE

1 15

16 30

PIN # 7

PIN # 20

1 15

GR

EEN/B

LACK YELLO

W/B

LACK

30-pin Connector located at BCM

CAUTION: THERE ARE TWOYELLOW/BLACK WIRES. USETHE ONE LOCATED AT PIN 20.

15-pin ConnectorLocated at BCM

E

F

Doc. No.: ##3461##

XX-XX PAGE X-XADS-AL(DL)-NI PAGE X-X

mOdULe PrOgramming PrOCedUre

5 Module Programming Procedure completed.

4 Turn key to OFF position.OFF

1 Insert key into ignition.

2 Turn key to ON position.

ON

3 Wait, LED will turn solid GREEN for 2 seconds.

mOdULe PrOgramming PrOCedUre WitH PUSH tO Start SyStem

4 Module Programming Procedure completed. 2 Wait, LED will turn solid GREEN

for 2 seconds.

1 DO NOT PRESS BRAKE PEDAL

Push start button twice [2x] to ON position.

x2 3 DO NOT PRESS BRAKE PEDAL

Push start button once [1x] to OFF position.

x1

inStaLLatiOn mOde SeLeCtiOn

1 PRESS AND RELEASE programming button to select installation mode.

OR

Remote Starter Standard Mode LED fl ashes twice

x2Remote Starter Data Mode LED fl ashes once

x1 ! After registration, follow Factory Reset Procedure to change installation mode and restart this procedure.

2 PRESS AND HOLDprogramming button until LED turns solid GREEN to register selection.

Page 5 of 6 OL-AL(MIB)-GD 20100326

iNstall Guide

omega research & development inc. © 2010

ImmobIlIzer bypassGM/Daewoo

Doc. No.: ##3461##

XX-XX PAGE X-X

mOdULe diagnOStiCS

CLASSIC-SERIES PAGE 1-1

FaCtOry reSet PrOCedUre

1 DISCONNECT all connectors from module EXCEPT the black 4-PIN power connector.

2 PRESS AND HOLD programming button while connecting either 4-PIN standard or 4-PIN optional data connector.

3 LED will fl ash red. Immediately RELEASE programming button. 4 LED will turn solid red for 2

seconds, RESET COMPLETED. Reconnect all connectors and repeat programming procedure.

FlasHING GreeNcorrectlyprogrammedand operational

solID reDincorrectlyprogrammed

FlasHING reDincorrectlyprogrammed

leD oFFinvalid groundwhen runningstatus from r.s.

leD oFFat rest and ready for ar.s. sequence

solID reD not programmed waiting for more vehicleinformation

FlasHING reDincorrectlyprogrammedor connected

FlasHING GreeNfalse groundwhen runningstatus from r.s.

solID reDwaitingfor more vehicleinformation

solID GreeNTHeN oFFcorrectlyprogrammed

FlasHING reDmissing/wrongconnection orfi rmware

leD oFFno activityor alreadyprogrammed

mOdULe diagnOStiCS DUrING proGrammING

DUrING remoTe sTarT (r.s.)

WITH IGNITIoN oFF

7 Repeat programming procedure.

1 DISCONNECT all connectors from module EXCEPT the black 4-PIN standard or optional data connector.

2 DISCONNECT black 4-PIN standard or optional data connector.

3 PRESS AND HOLD programming button while connecting either 4-PIN standard or optional data connector.

6 RECONNECT all connectors.

4 When LED fl ashes red, RELEASE programming button.

5 LED will turn solid red for 2 seconds.

RESET COMPLETED.

! Failure to follow procedure may result with a DTC or a CHECK ENGINE error message.

Page 6 of 6 OL-AL(MIB)-GD 20100326

iNstall Guide

omega research & development inc. © 2010

ImmobIlIzer bypassGM/Daewoo

Doc. No.: ##3461##