omega r&d inc. iNstall Guide OL-AL(MIB)-GD · CHeVroleT Aveo ( LS ) 04-08 1 Aveo 5 ( LS ) 04-08 1...
Transcript of omega r&d inc. iNstall Guide OL-AL(MIB)-GD · CHeVroleT Aveo ( LS ) 04-08 1 Aveo 5 ( LS ) 04-08 1...
NOTICE: The manufacturer will accept no responsibility for any electrical damage resulting from improper installation of this product, be that either damage to the vehicle itself or to the installed device. This device must be installed by a certified technician. This guide has been written for properly trained technicians; a certain level of skill & knowledge is therefore assumed. Please review the Installation Guide carefully before beginning any work.
!
omega r&d inc.
iNstall Guide OL-AL(MIB)-GD AvAILABLe fOR : OL-MIB-ALL
GD
The brand names and logos found in this guide are property of their respective owners. Omega R&D Inc. © 2010
Rev. Date: June 17, 2010Doc. No.: ##3461##20100326
A l a r m s & R e m o t e S t a r t
inStaLL tyPe SeLeCtiOn
XX-XX PAGE X-XADS-TB-GD PAGE 2-2
ma
Ke
mo
Del
yea
r
INsT
all
Typ
e
CH
eVr
ole
T Aveo ( LS ) 04-08 1
Aveo 5 ( LS ) 04-08 1
Epica ( LS / LT ) 04-07 2p
oN
TIa
C Wave 05-08 1
Wave 5 05-08 1
sUzU
KI
Swift+ 04-08 1
Verona 04-06 2
Page 2 of 6 OL-AL(MIB)-GD 20100326
iNstall Guide
omega research & development inc. © 2010
ImmobIlIzer bypassGM/Daewoo
Doc. No.: ##3461##
tyPe 1 - Wiring diagram
XX-XX PAGE X-X
tyPe 1 - Wire CrOSS reFerenCe CHart
ADS-AL(TB)-GD T1 PAGE X-X
ma
Ke
mo
Del
yea
r
IGNITIoN DaTa CoNNeCTor
po
sITI
oN
WIr
e C
olo
r
po
sITI
oN
WIr
e C
olo
r
Na
me
Typ
e
loCa
TIo
N
CH
eVr
ole
T Aveo ( LS ) 04-07 1 Pink 6 Black/White D 7 pin At key barrel
Aveo ( LS ) 08 1 Pink 6 Brown/White D 7 pin At key barrel
Aveo 5 ( LS ) 04-07 1 Pink 6 Black/White D 7 pin At key barrel
Aveo 5 ( LS ) 08 1 Pink 6 Brown/White D 7 pin At key barrel
po
NTI
aC Wave 05-07 1 Pink 6 Black/White D 7 pin At key barrel
Wave 08 1 Pink 6 Brown/White D 7 pin At key barrel
Wave 5 05-07 1 Pink 6 Black/White D 7 pin At key barrel
Wave 5 08 1 Pink 6 Brown/White D 7 pin At key barrel
sUzU
KI Swift+ 04-07 1 Pink 6 Black/White D 7 pin At key barrel
Swift+ 08 1 Pink 6 Brown/White D 7 pin At key barrel
Page 3 of 6 OL-AL(MIB)-GD 20100326
iNstall Guide
omega research & development inc. © 2010
ImmobIlIzer bypassGM/Daewoo
MOVE THE FOLLOWING ITEMS IN YOURSCHEMATIC WITH ALL LAYERS ON
USE THE FOLLOWING LAYER SPECIFIC ITEMS ASWIRING AND TEXT TEMPLATES
CONNECT EITHER DBI OR
STANDARD WIRING
DBI PORT REQUIREDON REMOTE STARTER. IF UNAVAILABLE
USE STANDARD WIRING METHOD
LEGEND
Wiring connections not requiredwhen using the DBI Port.
DBI PORT
BLUE/RED (NC) BLUE/YELLOW (NC)GREEN/RED (NC)GREEN/YELLOW (NC)GRAY/RED (NC)GRAY/YELLOW (NC)
ORANGE (NC)ORANGE/WHITE (NC) ORANGE/BLACK - DATABROWN/YELLOW (NC)BROWN/RED (NC)
YELLOW (NC)YELLOW/RED (NC)YELLOW/BLACK (NC)
PINK/BLACK - IGNITION OUTPUTPINK - IGNITION INPUT
GWR (-) - BLUE/WHITE(NC) WHITE
GROUND - BLACK12V - RED
REMOTESTARTER
OR
SECURITYSYSTEM
OR
KEYLESSENTRY
WHITE (NC) WHITE/RED - ALARM OUT FUSE WHITE/BLACK - ALARM IN ECM
(NC) GREEN/BLACK(NC) BLUE/BLACK
(NC) RED/WHITE (NC) BROWN
(NC) PURPLE/YELLOW (NC) PURPLE/BLACK
(NC) INPUT - WHITE(NC) BLACK/WHITE
(NC) GREEN(NC) PURPLE/WHITE
OPTIONAL USE TO ISOLATE OEM ALARM IGNITION PINK WIRE BEHIND CENTER CONSOLE
PIN
K - IG
NITIO
N FR
OM
ECM
BLA
CK/W
HITE O
R B
RO
WN
/WH
ITE - DA
TA
If the ignition wire (located behind center console) is interupted by the iDatalink module, there is no need to override the vehicle factory alarm. This installation method will ensure your factory keyfob will at all times function normally (including during remote start).
Front view of connector
D
Doc. No.: ##3461##
tyPe 2 - Wiring diagram
XX-XX PAGE X-X
Wire CrOSS reFerenCe CHart
XX-XX PAGE X-X
tyPe 2 - Wire CrOSS reFerenCe CHart
ADS-AL(TB)-GD T2 PAGE X-X
ma
Ke
mo
Del
yea
r
DaTa CoNNeCTor seCUrITy lIGHT CoNNeCTor
po
sITI
oN
WIr
e C
olo
r
Na
me
Typ
e
loCa
TIo
N
po
sITI
oN
WIr
e C
olo
r
Na
me
Typ
e
loCa
TIo
N
CH
eVr
ole
T
Epica ( LS / LT ) 04-07 7 Green/Black E 15 pin At BCM 20 Yellow/Black F 30 pin At BCM
sUzU
KI
Verona 04-06 7 Green/Black E 15 pin At BCM 20 Yellow/Black F 30 pin At BCM
Page 4 of 6 OL-AL(MIB)-GD 20100326
iNstall Guide
omega research & development inc. © 2010
ImmobIlIzer bypassGM/Daewoo
MOVE THE FOLLOWING ITEMS IN YOURSCHEMATIC WITH ALL LAYERS ON
USE THE FOLLOWING LAYER SPECIFIC ITEMS ASWIRING AND TEXT TEMPLATES
CONNECT EITHER DBI OR
STANDARD WIRING
DBI PORT REQUIREDON REMOTE STARTER. IF UNAVAILABLE
USE STANDARD WIRING METHOD
LEGEND
Wiring connections not requiredwhen using the DBI Port.
DBI PORT
BLUE/RED - SECURITY LIGHT INBLUE/YELLOW - SECURITY LIGHT OUTGREEN/RED (NC)GREEN/YELLOW (NC)GRAY/RED (NC)GRAY/YELLOW (NC)
ORANGE (NC)ORANGE/WHITE (NC) ORANGE/BLACK - DATABROWN/YELLOW (NC)BROWN/RED (NC)
YELLOW (NC)YELLOW/RED (NC)YELLOW/BLACK (NC)
PINK/BLACK (NC)PINK - IGNITION (+) INPUT
GWR (-) - BLUE/WHITE(NC) WHITE
GROUND - BLACK12V - RED
REMOTESTARTER
OR
SECURITYSYSTEM
OR
KEYLESSENTRY
WHITE (NC) WHITE/RED - DATA ECM SIDEWHITE/BLACK - DATA BCM SIDE
(NC) GREEN/BLACK(NC) BLUE/BLACK
(NC) RED/WHITE (NC) BROWN
(NC) PURPLE/YELLOW (NC) PURPLE/BLACK
(NC) INPUT - WHITE(NC) BLACK/WHITE
(NC) GREEN(NC) PURPLE/WHITE
1 15
16 30
PIN # 7
PIN # 20
1 15
GR
EEN/B
LACK YELLO
W/B
LACK
30-pin Connector located at BCM
CAUTION: THERE ARE TWOYELLOW/BLACK WIRES. USETHE ONE LOCATED AT PIN 20.
15-pin ConnectorLocated at BCM
E
F
Doc. No.: ##3461##
XX-XX PAGE X-XADS-AL(DL)-NI PAGE X-X
mOdULe PrOgramming PrOCedUre
5 Module Programming Procedure completed.
4 Turn key to OFF position.OFF
1 Insert key into ignition.
2 Turn key to ON position.
ON
3 Wait, LED will turn solid GREEN for 2 seconds.
mOdULe PrOgramming PrOCedUre WitH PUSH tO Start SyStem
4 Module Programming Procedure completed. 2 Wait, LED will turn solid GREEN
for 2 seconds.
1 DO NOT PRESS BRAKE PEDAL
Push start button twice [2x] to ON position.
x2 3 DO NOT PRESS BRAKE PEDAL
Push start button once [1x] to OFF position.
x1
inStaLLatiOn mOde SeLeCtiOn
1 PRESS AND RELEASE programming button to select installation mode.
OR
Remote Starter Standard Mode LED fl ashes twice
x2Remote Starter Data Mode LED fl ashes once
x1 ! After registration, follow Factory Reset Procedure to change installation mode and restart this procedure.
2 PRESS AND HOLDprogramming button until LED turns solid GREEN to register selection.
Page 5 of 6 OL-AL(MIB)-GD 20100326
iNstall Guide
omega research & development inc. © 2010
ImmobIlIzer bypassGM/Daewoo
Doc. No.: ##3461##
XX-XX PAGE X-X
mOdULe diagnOStiCS
CLASSIC-SERIES PAGE 1-1
FaCtOry reSet PrOCedUre
1 DISCONNECT all connectors from module EXCEPT the black 4-PIN power connector.
2 PRESS AND HOLD programming button while connecting either 4-PIN standard or 4-PIN optional data connector.
3 LED will fl ash red. Immediately RELEASE programming button. 4 LED will turn solid red for 2
seconds, RESET COMPLETED. Reconnect all connectors and repeat programming procedure.
FlasHING GreeNcorrectlyprogrammedand operational
solID reDincorrectlyprogrammed
FlasHING reDincorrectlyprogrammed
leD oFFinvalid groundwhen runningstatus from r.s.
leD oFFat rest and ready for ar.s. sequence
solID reD not programmed waiting for more vehicleinformation
FlasHING reDincorrectlyprogrammedor connected
FlasHING GreeNfalse groundwhen runningstatus from r.s.
solID reDwaitingfor more vehicleinformation
solID GreeNTHeN oFFcorrectlyprogrammed
FlasHING reDmissing/wrongconnection orfi rmware
leD oFFno activityor alreadyprogrammed
mOdULe diagnOStiCS DUrING proGrammING
DUrING remoTe sTarT (r.s.)
WITH IGNITIoN oFF
7 Repeat programming procedure.
1 DISCONNECT all connectors from module EXCEPT the black 4-PIN standard or optional data connector.
2 DISCONNECT black 4-PIN standard or optional data connector.
3 PRESS AND HOLD programming button while connecting either 4-PIN standard or optional data connector.
6 RECONNECT all connectors.
4 When LED fl ashes red, RELEASE programming button.
5 LED will turn solid red for 2 seconds.
RESET COMPLETED.
! Failure to follow procedure may result with a DTC or a CHECK ENGINE error message.
Page 6 of 6 OL-AL(MIB)-GD 20100326
iNstall Guide
omega research & development inc. © 2010
ImmobIlIzer bypassGM/Daewoo
Doc. No.: ##3461##