Olsen Medical Ercon Catheter Products New Brochures 2010

4
Ercon Catheter Products Ercon Catheter Products, state of the art, punching and skiving systems are capable of creating a variety of hole sizes and shapes. The systems are designed to meet your specific requirements. Precision punching: holes can be punched from .040 inches (1 mm) in diameter. SYSTEM REQUIREMENTS Operated by foot switch Electrical: 115 VAC or 230 VAC Air Pressure: 80-100 psi SYSTEM CAPABILITIES Punched holes can be round, oval, or irregular in shape Holes can be punched through the tube side wall • Holes can be punched straight through both sides • Holes can be punched straight one side Holes can be punched through a single lumen of multiple lumen tubes • Multiple holes can be punched simultaneously Tubing can be cut to length • Tubing can be indexed between punch operations for special hole patterns • Quick change modules allow many styles of holes to be punched using one system • Modules are designed to punch and/or cut-off tubing to specific configurations HOLE PUNCHING SYSTEMS www.olsenmedical.com [email protected] 3230 Commerce Center Place Louisville, KY 40211 Oregon Sales Office Phone (503) 781-0184 Fax (503) 536-6688

Transcript of Olsen Medical Ercon Catheter Products New Brochures 2010

Ercon Catheter Products

Ercon Catheter Products, state of the art, punching and

skiving systems are capable of creating a variety of hole

sizes and shapes. The systems are designed to meet

your specific requirements.

Precision punching: holes can be punched from

.040 inches (1 mm) in diameter.

SyStem RequiRementS

• Operated by foot switch

• Electrical: 115 VAC or 230 VAC

• Air Pressure: 80-100 psi

SyStem CapabilitieS

• Punched holes can be round, oval, or irregular in shape

• Holes can be punched through the tube side wall

• Holes can be punched straight through both sides

• Holes can be punched straight one side

• Holes can be punched through a single lumen of multiple lumen tubes

• Multiple holes can be punched simultaneously

• Tubing can be cut to length

• Tubing can be indexed between punch operations for special hole patterns

• Quick change modules allow many styles of holes to be punched using one system

• Modules are designed to punch and/or cut-off tubing to specific configurations

Hole PuncHing SyStemS

[email protected]

3230 Commerce Center Place Louisville, KY 40211

Oregon Sales OfficePhone (503) 781-0184

Fax (503) 536-6688

Ercon Catheter Products

Ercon Catheter Products name is synonymous with the design and fabrication of high-quality and reliable Tip Forming and Hole Punching Systems. For over 15 years, our systems have been in operation in catheter manufacturing facilities worldwide.

From Concept to Production our engineering services will provide a proven design and manufacturing process that will help you get to market faster. All of our catheter manufacturing is designed to customer specifications where we utilize a class 100,000 clean room.

We will design customized tooling for your application and provide samples for your approval prior to production. We have the equipment and experience in-house to keep your start-up costs low and your deliveries on-time.

Whether it is a tip forming or hole punching application, Ercon Catheter Products can produce the precise, repeatable product that you seek, as well as the service and support that you need.

let uS manufaCtuRe youR pRoduCt

• Precise, Repeatable Tip Forming and Hole Punching

• Engineering and Design

• Technical Support and Service

• Supply Chain Management

• Customized Tooling

• Clean Room: Class 100,000

• Packaging and Labeling

• Sterilization Services

• Over 15 Years of Experience and Expertise

• On-time Deliveries

contract manufacturing

[email protected]

3230 Commerce Center Place Louisville, KY 40211

Oregon Sales OfficePhone (503) 781-0184

Fax (503) 536-6688

Ercon Catheter Products

This equipment is used to assemble the catheter tubing to the molded hub and form the tips. Each machine

requires special tooling for each different size of catheter. The tooling is designed for a specific style of

catheter, and can be designed to any hub desired; standard,

winged, or with ports. flanging/flaRing equipment

• This unit is used to form a flange or flare on the I.V. tube where it fits into the molded hub. The flange or flare is required whether you ultrasonically weld or insert mold the two pats together. This system is a shuttle unit, which uses one operator to load one side while the other side is forming.

i.V. tip foRming equipment

• The I.V. Tip forming machine forms a very precise taper on I.V. Catheter tubing. The tubes can be formed after assembly with the hubs or prior to the assembly. Sizes range from 26Ga. to 14Ga. or larger. Tube holding fixtures can accommodate standard hubs, winged hubs, or hubs with ports.

i.V. aSSembly equiPment

[email protected]

3230 Commerce Center Place Louisville, KY 40211

Oregon Sales OfficePhone (503) 781-0184

Fax (503) 536-6688

Ercon Catheter Products

We can create a tip forming system to meet the needs

of your particular application. Our tip forming systems

incorporate the Ameritherm® Solid State RF Induction

Generator, which quickly obtain desired temperatures,

producing fast cycle times.

Combined with solid state electronics, PLC control, and

a programmable touch-screen display, you are getting the

highest quality, and performance from each and every

cycle.

The tip forming system is also equipped with quick change

tooling, allowing multiple size catheters to be run on the

same machine. Our standard tip forming equipment can

produce 1 to 4 catheters at a time, with special systems

capable of producing up to 30 catheters per minute.

SyStem featuReS

• Time controlled cycle• Solid state generator 1kW, 2kW, 2.4kW, 4.2kW• Easy troubleshooting features• Dual finger switches as an option• Precise control of the forming process• Tight tolerances• Smooth surfaces• No flash• Maximum performance• PLC control with touch-screen display and customized control

SyStem RequiRementS

• Operated by foot switch• Electrical: 115 VAC or 230 VAC• Air Pressure: 80-100 psi

SyStem CapabilitieS

• Highly repeatable precision formed catheter tips• Welding plastic to plastic• Bonding plastic to metal• Bonding balloons with smooth joint transition• Spot sealing of lumens• Closed or tapered tubing ends• Forming of neck downs and flares• Radius both tip ID and OD• Braided and non-braided tubing• Forming of intricate shapes• Improved output quality• Quantifiable and Validate-able process

typiCal tubing end pRofileS

• Closed end spherical radius• Closed end bullet nose• Open end delee• Open end whistle tip• Coudé

catHeter tiP forming SyStemS

[email protected]

3230 Commerce Center Place Louisville, KY 40211

Oregon Sales OfficePhone (503) 781-0184

Fax (503) 536-6688